{"lab":{"_id":"69ad52a3de79e566650fb8c9","accr_number":"AB 1669","country":"PL","accr_body":"PCA","address":"SPÓŁKA JAWNA, Pawłówko, ul. Bydgoska 14, 89-620 Chojnice","categories":["construction"],"city":"Chojnice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"AG-CEL LABORATORIUM P. RYDYGIER, I. TRZYNSKI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1669.pdf"],"scope_summary":"","search_text":"ag-cel laboratorium p. rydygier, i. trzynski spółka jawna, pawłówko, ul. bydgoska 14, 89-620 chojnice construction other water environment electronics materials","status":"active","updated_at":"2026-03-08T14:50:48.117Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:48.117Z","email_confidence":"high","email_mx":true,"email_source":"https://agcel.pl/kontakt/","parse_date":"2026-07-17T16:19:17.600Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Mechanical tests and sampling of building products, building materials and building items"},{"codes":"J/5; J/27","pl":"Badania mechaniczne wyrobów budowlanych, obiektów budowlanych i drewna","en":"Mechanical tests of building products, building items and wood"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Physical properties tests and sampling of building products, building materials and building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów i obiektów budowlanych","en":"Test of physical properties of building products and building items"}],"issue":{"no":"9","date":"20.10.2025"},"map_coord":[53.690865,17.61157],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":38,"other":5,"materials":2,"water":2},"category_scores":{"construction":30.72,"other":0.53,"materials":0.09,"water":0.09},"has_zh":true},"methods":[{"_id":"6a5a56059af9f73f38254c95","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja Zakres: (10 - 210) mm Metoda opadu stożka","methodology_en":"Consistency Range: (10 - 210) mm Slump test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Konsystencja Zakres: (10 - 210) mm Metoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja Zakres: (10 - 210) mm Metoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja Zakres: (10 - 210) mm Metoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fresh concrete Consistency Range: (10 - 210) mm Slump test method PN-EN 12350-2:2019-07","search_zh":"混凝土拌合物 PN-EN 12350-2:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a5a56059af9f73f38254c96","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Zawartość powietrza Zakres: (0,1 - 10) % Metoda ciśnieniomierza","methodology_en":"Air content Range: (0,1 - 10) % Pressure gauge method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość powietrza Zakres: (0,1 - 10) % Metoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Zawartość powietrza Zakres: (0,1 - 10) % Metoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza Zakres: (0,1 - 10) % Metoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fresh concrete Air content Range: (0,1 - 10) % Pressure gauge method PN-EN 12350-7:2019-08","search_zh":"混凝土拌合物 PN-EN 12350-7:2019-08","test_object_zh":"混凝土拌合物"},{"_id":"6a5a56059af9f73f38254c97","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06","norm_bases":["PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06","categories":["construction"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07 PN-EN 12350-1:2019-07/Ap1:2022- 06","test_object_zh":"混凝土拌合物"},{"_id":"6a5a56059af9f73f38254c98","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","methodology_en":"Compressive strength Force range: (60 - 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie Zakres sily: (60 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Compressive strength Force range: (60 - 3000) kN PN-EN 12390-3:2019-07","search_zh":"混凝土 抗压强度 力值范围：(60 - 3000) kN PN-EN 12390-3:2019-07","test_object_zh":"混凝土","methodology_zh":"抗压强度 力值范围：(60 - 3000) kN"},{"_id":"6a5a56059af9f73f38254c99","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na działanie mrozu Metoda zwykła","methodology_en":"Resistance to freezing Ordinary method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie mrozu Metoda zwykła","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na działanie mrozu Metoda zwykła PN-88/B-06250 Beton Odpornosc na dzialanie mrozu Metoda zwykla PN-88/B-06250","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Resistance to freezing Ordinary method PN-88/B-06250","search_zh":"混凝土 抗冻性 常规法 PN-88/B-06250","test_object_zh":"混凝土","methodology_zh":"抗冻性 常规法"},{"_id":"6a5a56059af9f73f38254c9a","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Water absorption PN-88/B-06250","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254c9b","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Gęstość PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Density PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254c9c","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Głębokość penetracji wody pod ciśnieniem","methodology_en":"Depth of penetration of water under pressure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Depth of penetration of water under pressure PN-EN 12390-8:2019-08","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254c9d","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Przepuszczalność wody","methodology_en":"Water permeability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Water permeability PN-88/B-06250","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254c9e","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na działanie mrozu","methodology_en":"Resistance to freezing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie mrozu","reference":"PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na działanie mrozu PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc na dzialanie mrozu PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Resistance to freezing PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254c9f","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność betonu na cykliczne zamrażanie-rozmrażanie w obecności soli odladzających","methodology_en":"Resistance of concrete to cyclic freeze-thaw in the presence of de-icing salts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność betonu na cykliczne zamrażanie-rozmrażanie w obecności soli odladzających","reference":"PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność betonu na cykliczne zamrażanie-rozmrażanie w obecności soli odladzających PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc betonu na cykliczne zamrazanie-rozmrazanie w obecnosci soli odladzajacych PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete Resistance of concrete to cyclic freeze-thaw in the presence of de-icing salts PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","search_zh":"混凝土 PN-B-06265:2022-08 | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土"},{"_id":"6a5a56059af9f73f38254ca0","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Mieszanki związane spoiwem hydraulicznym","test_object_en":"Hydraulically bound mixtures","methodology":"Wytrzymałość na ściskanie Zakres (1 - 3000) kN","methodology_en":"Compressive strength Range (1 - 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres (1 - 3000) kN","reference":"PN-EN 13286-41:2022-04","norm_bases":["PN-EN 13286-41:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanki związane spoiwem hydraulicznym Wytrzymałość na ściskanie Zakres (1 - 3000) kN PN-EN 13286-41:2022-04 Mieszanki zwiazane spoiwem hydraulicznym Wytrzymalosc na sciskanie Zakres (1 - 3000) kN PN-EN 13286-41:2022-04","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulically bound mixtures Compressive strength Range (1 - 3000) kN PN-EN 13286-41:2022-04","search_zh":"水硬性胶结料结合的混合料 PN-EN 13286-41:2022-04","test_object_zh":"水硬性胶结料结合的混合料"},{"_id":"6a5a56059af9f73f38254ca1","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem","test_object_en":"Sub-base and improved subgrade of cement-stabilised soil","methodology":"Wytrzymałość na ściskanie Zakres (2 - 50) kN","methodology_en":"Compressive strength Range (2 - 50) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres (2 - 50) kN","reference":"PN-S-96012:1997","norm_bases":["PN-S-96012:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem Wytrzymałość na ściskanie Zakres (2 - 50) kN PN-S-96012:1997 Podbudowa i ulepszone podloze z gruntu stabilizowanego cementem Wytrzymalosc na sciskanie Zakres (2 - 50) kN PN-S-96012:1997","categories":["construction"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sub-base and improved subgrade of cement-stabilised soil Compressive strength Range (2 - 50) kN PN-S-96012:1997"},{"_id":"6a5a56059af9f73f38254ca2","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Mieszanki związane spoiwem hydraulicznym Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem","test_object_en":"Hydraulically bound mixtures Base course and improved subgrade of cement-stabilised soil","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 13286-1:2022-04 PN-EN 932-1:1999","norm_bases":["PN-EN 13286-1:2022-04 PN-EN 932-1:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanki związane spoiwem hydraulicznym Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem Pobieranie próbek PN-EN 13286-1:2022-04 PN-EN 932-1:1999 Mieszanki zwiazane spoiwem hydraulicznym Podbudowa i ulepszone podloze z gruntu stabilizowanego cementem Pobieranie probek PN-EN 13286-1:2022-04 PN-EN 932-1:1999","categories":["construction"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Hydraulically bound mixtures Base course and improved subgrade of cement-stabilised soil Sampling PN-EN 13286-1:2022-04 PN-EN 932-1:1999","methodology_zh":"样品采集","search_zh":"水硬性胶结料结合的混合料；水泥稳定土基层与改良路基 样品采集 PN-EN 13286-1:2022-04 PN-EN 932-1:1999","test_object_zh":"水硬性胶结料结合的混合料；水泥稳定土基层与改良路基"},{"_id":"6a5a56059af9f73f38254ca3","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.8","norm_bases":["PN-EN 932-1:1999 p. 8.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p. 8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p. 8.8","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Aggregates Sampling PN-EN 932-1:1999 p. 8.8","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999 p. 8.8","test_object_zh":"骨料"},{"_id":"6a5a56059af9f73f38254ca4","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Wymiary","methodology_en":"Dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary","reference":"PN-EN 1338:2005 Załącznik C PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005 Załącznik C PN-EN 1338:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Wymiary PN-EN 1338:2005 Załącznik C PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Wymiary PN-EN 1338:2005 Zalacznik C PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Dimensions PN-EN 1338:2005 Załącznik C PN-EN 1338:2005/AC:2007","methodology_zh":"尺寸","search_zh":"混凝土铺路砖 尺寸 PN-EN 1338:2005 Załącznik C PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a5a56059af9f73f38254ca5","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres siły: (60 - 3000) kN","methodology_en":"Splitting tensile strength Force range: (60 - 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu Zakres siły: (60 - 3000) kN","reference":"PN-EN 1338:2005 Załącznik F PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005 Załącznik F PN-EN 1338:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Wytrzymałość na rozciąganie przy rozłupywaniu Zakres siły: (60 - 3000) kN PN-EN 1338:2005 Załącznik F PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Wytrzymalosc na rozciaganie przy rozlupywaniu Zakres sily: (60 - 3000) kN PN-EN 1338:2005 Zalacznik F PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Splitting tensile strength Force range: (60 - 3000) kN PN-EN 1338:2005 Załącznik F PN-EN 1338:2005/AC:2007","search_zh":"混凝土铺路砖 PN-EN 1338:2005 Załącznik F PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a5a56059af9f73f38254ca6","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie","reference":"PN-EN 1338:2005 Załącznik H PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005 Załącznik H PN-EN 1338:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Odporność na ścieranie PN-EN 1338:2005 Załącznik H PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Odpornosc na scieranie PN-EN 1338:2005 Zalacznik H PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Abrasion resistance PN-EN 1338:2005 Załącznik H PN-EN 1338:2005/AC:2007","methodology_zh":"耐磨性","search_zh":"混凝土铺路砖 耐磨性 PN-EN 1338:2005 Załącznik H PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a5a56059af9f73f38254ca7","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 1338:2005 Załącznik E PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005 Załącznik E PN-EN 1338:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Nasiąkliwość PN-EN 1338:2005 Załącznik E PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Nasiakliwosc PN-EN 1338:2005 Zalacznik E PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Water absorption PN-EN 1338:2005 Załącznik E PN-EN 1338:2005/AC:2007","methodology_zh":"吸水率","search_zh":"混凝土铺路砖 吸水率 PN-EN 1338:2005 Załącznik E PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a5a56059af9f73f38254ca8","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","methodology_en":"Freeze/thaw resistance with de-icing salts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","reference":"PN-EN 1338:2005 Załącznik D PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005 Załącznik D PN-EN 1338:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających PN-EN 1338:2005 Załącznik D PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Odpornosc na zamrazanie/ rozmrazanie z udzialem soli odladzajacych PN-EN 1338:2005 Zalacznik D PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Freeze/thaw resistance with de-icing salts PN-EN 1338:2005 Załącznik D PN-EN 1338:2005/AC:2007","search_zh":"混凝土铺路砖 含除冰盐的抗冻融性 PN-EN 1338:2005 Załącznik D PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5a56059af9f73f38254ca9","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","norm_bases":["PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Pobieranie próbek PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2 Betonowe kostki brukowe Pobieranie probek PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Zalacznik B.2","categories":["construction"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving blocks Sampling PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","methodology_zh":"样品采集","search_zh":"混凝土铺路砖 样品采集 PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","test_object_zh":"混凝土铺路砖"},{"_id":"6a5a56059af9f73f38254caa","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Wymiary","methodology_en":"Dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary","reference":"PN-EN 1340:2004 Załącznik C PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004 Załącznik C PN-EN 1340:2004/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Wymiary PN-EN 1340:2004 Załącznik C PN-EN 1340:2004/AC:2007 Betonowe krawezniki Wymiary PN-EN 1340:2004 Zalacznik C PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Dimensions PN-EN 1340:2004 Załącznik C PN-EN 1340:2004/AC:2007","methodology_zh":"尺寸","search_zh":"混凝土路缘石 尺寸 PN-EN 1340:2004 Załącznik C PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石"},{"_id":"6a5a56059af9f73f38254cab","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Wytrzymałość na zginanie Zakres siły: (1 - 100) kN","methodology_en":"Bending strength Force range: (1 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres siły: (1 - 100) kN","reference":"PN-EN 1340:2004 Załącznik F PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004 Załącznik F PN-EN 1340:2004/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Wytrzymałość na zginanie Zakres siły: (1 - 100) kN PN-EN 1340:2004 Załącznik F PN-EN 1340:2004/AC:2007 Betonowe krawezniki Wytrzymalosc na zginanie Zakres sily: (1 - 100) kN PN-EN 1340:2004 Zalacznik F PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Bending strength Force range: (1 - 100) kN PN-EN 1340:2004 Załącznik F PN-EN 1340:2004/AC:2007","search_zh":"混凝土路缘石 PN-EN 1340:2004 Załącznik F PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石"},{"_id":"6a5a56059af9f73f38254cac","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie","reference":"PN-EN 1340:2004 Załącznik H PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004 Załącznik H PN-EN 1340:2004/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Odporność na ścieranie PN-EN 1340:2004 Załącznik H PN-EN 1340:2004/AC:2007 Betonowe krawezniki Odpornosc na scieranie PN-EN 1340:2004 Zalacznik H PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Abrasion resistance PN-EN 1340:2004 Załącznik H PN-EN 1340:2004/AC:2007","methodology_zh":"耐磨性","search_zh":"混凝土路缘石 耐磨性 PN-EN 1340:2004 Załącznik H PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石"},{"_id":"6a5a56059af9f73f38254cad","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 1340:2004 Załącznik E PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004 Załącznik E PN-EN 1340:2004/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Nasiąkliwość PN-EN 1340:2004 Załącznik E PN-EN 1340:2004/AC:2007 Betonowe krawezniki Nasiakliwosc PN-EN 1340:2004 Zalacznik E PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Water absorption PN-EN 1340:2004 Załącznik E PN-EN 1340:2004/AC:2007","methodology_zh":"吸水率","search_zh":"混凝土路缘石 吸水率 PN-EN 1340:2004 Załącznik E PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石"},{"_id":"6a5a56059af9f73f38254cae","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","methodology_en":"Freeze/thaw resistance with de-icing salts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","reference":"PN-EN 1340:2004 Załącznik D PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004 Załącznik D PN-EN 1340:2004/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających PN-EN 1340:2004 Załącznik D PN-EN 1340:2004/AC:2007 Betonowe krawezniki Odpornosc na zamrazanie/ rozmrazanie z udzialem soli odladzajacych PN-EN 1340:2004 Zalacznik D PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Freeze/thaw resistance with de-icing salts PN-EN 1340:2004 Załącznik D PN-EN 1340:2004/AC:2007","search_zh":"混凝土路缘石 含除冰盐的抗冻融性 PN-EN 1340:2004 Załącznik D PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5a56059af9f73f38254caf","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe krawężniki","test_object_en":"Concrete kerb units","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Załącznik B.2","norm_bases":["PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Załącznik B.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe krawężniki Pobieranie próbek PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Załącznik B.2 Betonowe krawezniki Pobieranie probek PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Zalacznik B.2","categories":["construction"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete kerb units Sampling PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Załącznik B.2","methodology_zh":"样品采集","search_zh":"混凝土路缘石 样品采集 PN-83/N-03010 p. 3.4 PN-EN 1340:2004 Załącznik B.2","test_object_zh":"混凝土路缘石"},{"_id":"6a5a56059af9f73f38254cb0","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Wymiary","methodology_en":"Dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary","reference":"PN-EN 1339:2005 Załącznik C PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005 Załącznik C PN-EN 1339:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Wymiary PN-EN 1339:2005 Załącznik C PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Wymiary PN-EN 1339:2005 Zalacznik C PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Dimensions PN-EN 1339:2005 Załącznik C PN-EN 1339:2005/AC:2007","methodology_zh":"尺寸","search_zh":"混凝土路面砖 尺寸 PN-EN 1339:2005 Załącznik C PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a5a56059af9f73f38254cb1","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Wytrzymałość na zginanie Zakres siły: (1 - 100) kN","methodology_en":"Bending strength Force range: (1 - 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres siły: (1 - 100) kN","reference":"PN-EN 1339:2005 Załącznik F PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005 Załącznik F PN-EN 1339:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Wytrzymałość na zginanie Zakres siły: (1 - 100) kN PN-EN 1339:2005 Załącznik F PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Wytrzymalosc na zginanie Zakres sily: (1 - 100) kN PN-EN 1339:2005 Zalacznik F PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Bending strength Force range: (1 - 100) kN PN-EN 1339:2005 Załącznik F PN-EN 1339:2005/AC:2007","search_zh":"混凝土路面砖 PN-EN 1339:2005 Załącznik F PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a5a56059af9f73f38254cb2","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ścieranie","reference":"PN-EN 1339:2005 Załącznik H PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005 Załącznik H PN-EN 1339:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Odporność na ścieranie PN-EN 1339:2005 Załącznik H PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Odpornosc na scieranie PN-EN 1339:2005 Zalacznik H PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Abrasion resistance PN-EN 1339:2005 Załącznik H PN-EN 1339:2005/AC:2007","methodology_zh":"耐磨性","search_zh":"混凝土路面砖 耐磨性 PN-EN 1339:2005 Załącznik H PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a5a56059af9f73f38254cb3","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 1339:2005 Załącznik E PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005 Załącznik E PN-EN 1339:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Nasiąkliwość PN-EN 1339:2005 Załącznik E PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Nasiakliwosc PN-EN 1339:2005 Zalacznik E PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Water absorption PN-EN 1339:2005 Załącznik E PN-EN 1339:2005/AC:2007","methodology_zh":"吸水率","search_zh":"混凝土路面砖 吸水率 PN-EN 1339:2005 Załącznik E PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a5a56059af9f73f38254cb4","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","methodology_en":"Freeze/thaw resistance with de-icing salts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających","reference":"PN-EN 1339:2005 Załącznik D PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005 Załącznik D PN-EN 1339:2005/AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Odporność na zamrażanie/ rozmrażanie z udziałem soli odladzających PN-EN 1339:2005 Załącznik D PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Odpornosc na zamrazanie/ rozmrazanie z udzialem soli odladzajacych PN-EN 1339:2005 Zalacznik D PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Freeze/thaw resistance with de-icing salts PN-EN 1339:2005 Załącznik D PN-EN 1339:2005/AC:2007","search_zh":"混凝土路面砖 含除冰盐的抗冻融性 PN-EN 1339:2005 Załącznik D PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5a56059af9f73f38254cb5","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","norm_bases":["PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Pobieranie próbek PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2 Betonowe plyty brukowe Pobieranie probek PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Zalacznik B.2","categories":["construction"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete paving flags Sampling PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","methodology_zh":"样品采集","search_zh":"混凝土路面砖 样品采集 PN-83/N-03010 p. 3.4 PN-EN 1338:2005 Załącznik B.2","test_object_zh":"混凝土路面砖"},{"_id":"6a5a56059af9f73f38254cb6","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Prefabrykaty z betonu","test_object_en":"Precast concrete products","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 13369:2005 Załącznik G","norm_bases":["PN-EN 13369:2005 Załącznik G"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Nasiąkliwość PN-EN 13369:2005 Załącznik G Prefabrykaty z betonu Nasiakliwosc PN-EN 13369:2005 Zalacznik G","categories":["construction"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Water absorption PN-EN 13369:2005 Załącznik G","methodology_zh":"吸水率","search_zh":"混凝土预制件 吸水率 PN-EN 13369:2005 Załącznik G","test_object_zh":"混凝土预制件"},{"_id":"6a5a56059af9f73f38254cb7","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Prefabrykaty z betonu","test_object_en":"Precast concrete products","methodology":"Wymiary","methodology_en":"Dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary","reference":"PN-EN 13369:2005 Załącznik J","norm_bases":["PN-EN 13369:2005 Załącznik J"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Wymiary PN-EN 13369:2005 Załącznik J Prefabrykaty z betonu Wymiary PN-EN 13369:2005 Zalacznik J","categories":["construction"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Dimensions PN-EN 13369:2005 Załącznik J","methodology_zh":"尺寸","search_zh":"混凝土预制件 尺寸 PN-EN 13369:2005 Załącznik J","test_object_zh":"混凝土预制件"},{"_id":"6a5a56059af9f73f38254cb8","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Prefabrykaty z betonu","test_object_en":"Precast concrete products","methodology":"Pobieranie próbek wyrobów","methodology_en":"Sampling of products","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wyrobów","reference":"PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r.","norm_bases":["PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty z betonu Pobieranie próbek wyrobów PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r. Prefabrykaty z betonu Pobieranie probek wyrobow PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r.","categories":["construction"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Precast concrete products Sampling of products PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r.","search_zh":"混凝土预制件 PN-83/N-03010 p. 3.4 Procedura PR-11 wydanie 2 z dnia 18.11.2019r.","test_object_zh":"混凝土预制件"},{"_id":"6a5a56059af9f73f38254cb9","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton w konstrukcjach","test_object_en":"Concrete in structures","methodology":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","methodology_en":"Compressive strength Force range: (60 - 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","reference":"PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07 Beton w konstrukcjach Wytrzymalosc na sciskanie Zakres sily: (60 - 3000) kN PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07","categories":["construction"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete in structures Compressive strength Force range: (60 - 3000) kN PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07","search_zh":"结构中的混凝土 抗压强度 力值范围：(60 - 3000) kN PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 PN-EN 12390-3:2019-07","test_object_zh":"结构中的混凝土","methodology_zh":"抗压强度 力值范围：(60 - 3000) kN"},{"_id":"6a5a56059af9f73f38254cba","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Beton w konstrukcjach","test_object_en":"Concrete in structures","methodology":"Pobieranie rdzeni","methodology_en":"Core sampling","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie rdzeni","reference":"PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01","norm_bases":["PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton w konstrukcjach Pobieranie rdzeni PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01 Beton w konstrukcjach Pobieranie rdzeni PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01","categories":["construction"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Concrete in structures Core sampling PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01","search_zh":"结构中的混凝土 PN-EN 12504-1:2019-08 PN-EN 12504-1:2019-08/AC:2021-01","test_object_zh":"结构中的混凝土"},{"_id":"6a5a56059af9f73f38254cbb","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Wymiary","methodology_en":"Dimensions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Wymiary PN-EN 772-16:2011 Elementy murowe Wymiary PN-EN 772-16:2011","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units Dimensions PN-EN 772-16:2011","methodology_zh":"尺寸","search_zh":"砌块 尺寸 PN-EN 772-16:2011","test_object_zh":"砌块"},{"_id":"6a5a56059af9f73f38254cbc","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","methodology_en":"Compressive strength Force range: (60 - 3000) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Wytrzymałość na ściskanie Zakres siły: (60 - 3000) kN PN-EN 772-1+A1:2015-10 Elementy murowe Wytrzymalosc na sciskanie Zakres sily: (60 - 3000) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Masonry units Compressive strength Force range: (60 - 3000) kN PN-EN 772-1+A1:2015-10","search_zh":"砌块 抗压强度 力值范围：(60 - 3000) kN PN-EN 772-1+A1:2015-10","test_object_zh":"砌块","methodology_zh":"抗压强度 力值范围：(60 - 3000) kN"},{"_id":"6a5a56059af9f73f38254cbd","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Drewno konstrukcyjne lite i klejone warstwowo","test_object_en":"Solid structural timber and glued laminated timber","methodology":"Wytrzymałość na zginanie Zakres siły: (1 – 100) kN","methodology_en":"Flexural strength Force range: (1 – 100) kN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie Zakres siły: (1 – 100) kN","reference":"PN-EN 408+A1:2012 p. 19","norm_bases":["PN-EN 408+A1:2012 p. 19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drewno konstrukcyjne lite i klejone warstwowo Wytrzymałość na zginanie Zakres siły: (1 – 100) kN PN-EN 408+A1:2012 p. 19 Drewno konstrukcyjne lite i klejone warstwowo Wytrzymalosc na zginanie Zakres sily: (1 – 100) kN PN-EN 408+A1:2012 p. 19","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid structural timber and glued laminated timber Flexural strength Force range: (1 – 100) kN PN-EN 408+A1:2012 p. 19"},{"_id":"6a5a56059af9f73f38254cbe","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 1917:2004 Załącznik D PN-EN 1917:2004/AC:2009","norm_bases":["PN-EN 1917:2004 Załącznik D PN-EN 1917:2004/AC:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Studzienki włazowe i niewłazowe z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Nasiąkliwość PN-EN 1917:2004 Załącznik D PN-EN 1917:2004/AC:2009 Studzienki wlazowe i niewlazowe z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Nasiakliwosc PN-EN 1917:2004 Zalacznik D PN-EN 1917:2004/AC:2009","categories":["construction","materials"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Manholes and inspection chambers of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Water absorption PN-EN 1917:2004 Załącznik D PN-EN 1917:2004/AC:2009","methodology_zh":"吸水率","search_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井 吸水率 PN-EN 1917:2004 Załącznik D PN-EN 1917:2004/AC:2009","test_object_zh":"素混凝土、钢纤维混凝土与钢筋混凝土的可进入式与不可进入式检查井"},{"_id":"6a5a56059af9f73f38254cbf","lab_id":"69ad52a3de79e566650fb8c9","country":"PL","accr_number":"AB 1669","accr_body":"PCA","test_object":"Rury i kształtki z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe","test_object_en":"Pipes and fittings of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 1916:2005 Załącznik F PN-EN 1916:2005/AC:2009","norm_bases":["PN-EN 1916:2005 Załącznik F PN-EN 1916:2005/AC:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury i kształtki z betonu niezbrojonego, z betonu zbrojonego włóknem stalowym i żelbetowe Nasiąkliwość PN-EN 1916:2005 Załącznik F PN-EN 1916:2005/AC:2009 Rury i ksztaltki z betonu niezbrojonego, z betonu zbrojonego wloknem stalowym i zelbetowe Nasiakliwosc PN-EN 1916:2005 Zalacznik F PN-EN 1916:2005/AC:2009","categories":["construction","materials"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Pipes and fittings of unreinforced concrete, steel fibre reinforced concrete and reinforced concrete Water absorption PN-EN 1916:2005 Załącznik F PN-EN 1916:2005/AC:2009","methodology_zh":"吸水率","search_zh":"吸水率 PN-EN 1916:2005 Załącznik F PN-EN 1916:2005/AC:2009"}],"has_pdf":true}