{"lab":{"_id":"69ad52a3de79e566650fb8af","accr_number":"AB 1650","country":"PL","accr_body":"PCA","address":"ul. Nadbystrzycka 38 D, 20-618 Lublin, WYDZIAŁ BUDOWNICTWA I ARCHITEKTURY, LABORATORIUM BUDOWNICTWA, ul. Nadbystrzycka 40, 20-618 Lublin","categories":["construction","materials"],"city":"Lublin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"POLITECHNIKA LUBELSKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1650.pdf"],"scope_summary":"","search_text":"politechnika lubelska ul. nadbystrzycka 38 d, 20-618 lublin, wydział budownictwa i architektury, laboratorium budownictwa, ul. nadbystrzycka 40, 20-618 lublin materials construction other","status":"active","updated_at":"2026-03-08T14:50:47.275Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:02:24.295Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201650,podmiot.html","parse_date":"2026-08-13T08:02:24.295Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5; J/8","pl":"Badania mechaniczne wyrobów budowlanych, wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests of building products, construction products and materials"},{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych","en":"Mechanical tests and sampling of building products"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of building products, materials"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów i materiałów budowlanych","en":"Tests of physical properties and sampling of building products and materials"},{"codes":"C/5","pl":"Badania chemiczne wyrobów budowlanych","en":"Chemical tests of building products"}],"issue":{"no":"8","date":"05.05.2026"},"map_coord":[51.235218,22.549245],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BUDOWNICTWA","address":"ul. Nadbystrzycka 40, 20-618 Lublin","city":"Lublin","postal":"20-618"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/243789b9fa9560f4c7a19f66908528a8/AB%201650.pdf","has_en":true,"category_counts":{"construction":8,"materials":1,"other":1},"category_scores":{"construction":6.4,"materials":0.1,"other":0.1},"has_zh":true},"methods":[{"_id":"6a7d7a100636ba417e41b0f7","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Metale i ich stopy, Wyroby konstrukcyjne","methodology":"Wytrzymałość na rozciąganie Rm","parameters":[{"name":"Zakres siły","range":"(5 – 500) kN"},{"name":"Próba rozciągania w temperaturze pokojowej"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie Rm\nZakres:\nZakres siły (5 – 500) kN\nPróba rozciągania w temperaturze pokojowej","reference":"PN-EN ISO 6892-1:2020-05 Metoda: B","norm_bases":["PN-EN ISO 6892-1:2020-05 Metoda: B"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i ich stopy, Wyroby konstrukcyjne Wytrzymałość na rozciąganie Rm\nZakres:\nZakres siły (5 – 500) kN\nPróba rozciągania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda: B Metale i ich stopy, Wyroby konstrukcyjne Wytrzymalosc na rozciaganie Rm\nZakres:\nZakres sily (5 – 500) kN\nProba rozciagania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda: B","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Tensile strength Rm","parameters_en":[{"name":"Force range","range":"(5 – 500) kN"},{"name":"Tensile test at room temperature"}],"search_en":"Metals and their alloys, Structural products Tensile strength Rm Construction Laboratory Force range Tensile test at room temperature PN-EN ISO 6892-1:2020-05 Metoda: B","test_object_en":"Metals and their alloys, Structural products","parameters_zh":[{"name":"力值范围","range":"(5 – 500) kN"},{"name":"室温拉伸试验"}],"search_zh":"抗拉强度 Rm 建筑工程实验室 力值范围 室温拉伸试验 PN-EN ISO 6892-1:2020-05 Metoda: B","lab_section_zh":"建筑工程实验室","methodology_zh":"抗拉强度 Rm"},{"_id":"6a7d7a100636ba417e41b0f8","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda: opadu stożka","techniques":["Metoda: opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda: opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda: opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda: opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Method: slump Construction Laboratory PN-EN 12350-2:2019-07","technique_en":"Method: slump","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 建筑工程实验室 PN-EN 12350-2:2019-07","test_object_zh":"混凝土拌合物","lab_section_zh":"建筑工程实验室"},{"_id":"6a7d7a100636ba417e41b0f9","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Sampling","search_en":"Fresh concrete Sampling Construction Laboratory PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 建筑工程实验室 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物","lab_section_zh":"建筑工程实验室"},{"_id":"6a7d7a100636ba417e41b0fa","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(60 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (60 – 3000) kN","reference":"PN-EN 12390-3:2019-07 | PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12390-3:2019-07","PN-EN 12504-1:2019-08"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres siły (60 – 3000) kN PN-EN 12390-3:2019-07 | PN-EN 12504-1:2019-08 Beton, Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres sily (60 – 3000) kN PN-EN 12390-3:2019-07 | PN-EN 12504-1:2019-08","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(60 – 3000) kN"}],"search_en":"Concrete, Concrete in structures Compressive strength Construction Laboratory Force range PN-EN 12390-3:2019-07 | PN-EN 12504-1:2019-08","test_object_en":"Concrete, Concrete in structures","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(60 – 3000) kN"}],"search_zh":"混凝土、结构中的混凝土 抗压强度 建筑工程实验室 力值范围 PN-EN 12390-3:2019-07 | PN-EN 12504-1:2019-08","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b0fb","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres siły","range":"(60 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (60 – 3000) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (60 – 3000) kN PN-EN 12390-6:2024-04 Beton, Beton w konstrukcjach Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres sily (60 – 3000) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Force range","range":"(60 – 3000) kN"}],"search_en":"Concrete, Concrete in structures Splitting tensile strength Construction Laboratory Force range PN-EN 12390-6:2024-04","test_object_en":"Concrete, Concrete in structures","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"力值范围","range":"(60 – 3000) kN"}],"search_zh":"混凝土、结构中的混凝土 劈裂抗拉强度 建筑工程实验室 力值范围 PN-EN 12390-6:2024-04","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b0fc","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Nasiąkliwość PN-88/B-06250 Beton, Beton w konstrukcjach Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Water absorption","search_en":"Concrete, Concrete in structures Water absorption Construction Laboratory PN-88/B-06250","test_object_en":"Concrete, Concrete in structures","methodology_zh":"吸水率","search_zh":"混凝土、结构中的混凝土 吸水率 建筑工程实验室 PN-88/B-06250","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b0fd","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Gęstość PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton, Beton w konstrukcjach Gestosc PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Density","search_en":"Concrete, Concrete in structures Density Construction Laboratory PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_en":"Concrete, Concrete in structures","methodology_zh":"密度","search_zh":"混凝土、结构中的混凝土 密度 建筑工程实验室 PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b0fe","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,010 – 1,000) %"}],"technique":"Metoda: miareczkowa Volharda","techniques":["Metoda: miareczkowa Volharda"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,010 – 1,000) %\nMetoda: miareczkowa Volharda","reference":"PN-EN 14629:2008","norm_bases":["PN-EN 14629:2008"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Zawartość chlorków\nZakres (0,010 – 1,000) %\nMetoda: miareczkowa Volharda PN-EN 14629:2008 Beton, Beton w konstrukcjach Zawartosc chlorkow\nZakres (0,010 – 1,000) %\nMetoda: miareczkowa Volharda PN-EN 14629:2008","categories":["construction"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,010 – 1,000) %"}],"search_en":"Concrete, Concrete in structures Chloride content Method: Volhard titrimetric Construction Laboratory Range PN-EN 14629:2008","technique_en":"Method: Volhard titrimetric","test_object_en":"Concrete, Concrete in structures","parameters_zh":[{"name":"范围","range":"(0,010 – 1,000) %"}],"search_zh":"混凝土、结构中的混凝土 氯化物含量 建筑工程实验室 范围 PN-EN 14629:2008","methodology_zh":"氯化物含量","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b0ff","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Beton, Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton, Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton, Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"Sampling","search_en":"Concrete, Concrete in structures Sampling Construction Laboratory PN-EN 12504-1:2019-08","test_object_en":"Concrete, Concrete in structures","methodology_zh":"样品采集","search_zh":"混凝土、结构中的混凝土 样品采集 建筑工程实验室 PN-EN 12504-1:2019-08","lab_section_zh":"建筑工程实验室","test_object_zh":"混凝土、结构中的混凝土"},{"_id":"6a7d7a100636ba417e41b100","lab_id":"69ad52a3de79e566650fb8af","country":"PL","accr_number":"AB 1650","accr_body":"PCA","test_object":"Ciała stałe","methodology":"Powierzchnia właściwa BET","parameters":[{"name":"Zakres","range":"(10 – 550) m2/g"}],"technique":"Metoda: sorpcji fizycznej","techniques":["Metoda: sorpcji fizycznej"],"computed":[],"activity":"Powierzchnia właściwa BET\nZakres (10 – 550) m2/g\nMetoda: sorpcji fizycznej","reference":"ISO 9277:2022","norm_bases":["ISO 9277:2022"],"lab_section":"Laboratorium Budownictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ciała stałe Powierzchnia właściwa BET\nZakres (10 – 550) m2/g\nMetoda: sorpcji fizycznej ISO 9277:2022 Ciala stale Powierzchnia wlasciwa BET\nZakres (10 – 550) m2/g\nMetoda: sorpcji fizycznej ISO 9277:2022","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Construction Laboratory","methodology_en":"BET specific surface area","parameters_en":[{"name":"Range","range":"(10 – 550) m2/g"}],"search_en":"Solids BET specific surface area Method: physical sorption Construction Laboratory Range ISO 9277:2022","technique_en":"Method: physical sorption","test_object_en":"Solids","parameters_zh":[{"name":"范围","range":"(10 – 550) m2/g"}],"search_zh":"建筑工程实验室 范围 ISO 9277:2022","lab_section_zh":"建筑工程实验室"}],"has_pdf":true}