{"lab":{"_id":"69ad52a3de79e566650fb8ab","accr_number":"AB 1648","country":"PL","accr_body":"PCA","address":"Laboratorium Badań Środowiska, al. Roździeńskiego 91, 40-203 Katowice","categories":["environment"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":46,"name":"Silesia Lab sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1648.pdf"],"scope_summary":"","search_text":"silesia lab sp. z o.o. laboratorium badań środowiska, al. roździeńskiego 91, 40-203 katowice environment metrology other pharma electronics materials construction","status":"active","updated_at":"2026-03-08T14:50:47.060Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:08:04.751Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201648,podmiot.html","parse_date":"2026-08-17T11:08:04.751Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne i drgań - maszyny","en":""},{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko pracy (czynniki szkodliwe i uciążliwe – pole elektromagnetyczne, drgania, oświetlenie, mikroklimat, hałas, wydatek energetyczny)","en":"Test concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field, vibrations, lighting, microclimate, noise, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests cocncerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"issue":{"no":"18","date":"13.05.2026"},"map_coord":[50.268183,19.055025],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badań Środowiska","address":"40-203 Katowice","city":"Katowice","postal":"40-203"},{"name":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/5fa01ba9cc93db7a5e0bd1bbf6e307c4/AB%201648.pdf","has_en":true,"category_counts":{"environment":42,"other":4,"construction":2,"materials":1},"category_scores":{"environment":36,"other":0.33,"construction":0.08,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a82eb94884ede9a1b2c488e","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(30 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 140) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82eb94884ede9a1b2c488f","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82eb94884ede9a1b2c4890","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A czynności m, Poziom ekspozycji na hałas odniesiony do 8-godzinnego dnia pracy odpowiadający udziałowi czynności m (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A czynności m, Poziom ekspozycji na hałas odniesiony do 8-godzinnego dnia pracy odpowiadający udziałowi czynności m (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A czynności m, Poziom ekspozycji na hałas odniesiony do 8-godzinnego dnia pracy odpowiadający udziałowi czynności m (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A czynnosci m, Poziom ekspozycji na halas odniesiony do 8-godzinnego dnia pracy odpowiadajacy udzialowi czynnosci m (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – noise PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82eb94884ede9a1b2c4891","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas, powiększony o niepewność przy 95% poziomie ufności, odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas, powiększony o niepewność przy 95% poziomie ufności, odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas, powiększony o niepewność przy 95% poziomie ufności, odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas, powiekszony o niepewnosc przy 95% poziomie ufnosci, odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82eb94884ede9a1b2c4892","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Maszyny i urządzenia - hałas","methodology":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A","parameters":[{"name":"Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A"},{"name":"Zakres","range":"(25-136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres:\nPoziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A\nZakres (25-136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia - hałas Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres:\nPoziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A\nZakres (25-136) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia - halas Poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa A\nZakres:\nPoziom cisnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyka czestotliwosciowa A\nZakres (25-136) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-frequency-weighted sound pressure level","parameters_en":[{"name":"A-weighted single event sound pressure level"},{"name":"Range","range":"(25-136) dB"}],"search_en":"Machinery and equipment - noise A-frequency-weighted sound pressure level Direct measurement method A-weighted single event sound pressure level Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment - noise","parameters_zh":[{"name":"Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A"},{"name":"范围","range":"(25-136) dB"}],"search_zh":"机器与设备 — 噪声 直接测量法 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 — 噪声"},{"_id":"6a82eb94884ede9a1b2c4893","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Maszyny i urządzenia - hałas","methodology":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia - hałas Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia - halas Poziom mocy akustycznej, Poziom energii akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level, Sound energy level (calculated)","search_en":"Machinery and equipment - noise Sound power level, Sound energy level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_en":"Machinery and equipment - noise","search_zh":"机器与设备 — 噪声 声功率级、声能量级（由计算得出） PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 — 噪声","methodology_zh":"声功率级、声能量级（由计算得出）"},{"_id":"6a82eb94884ede9a1b2c4894","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25-120) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25-120) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25-120) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25-120) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25-120) dB"}],"search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level Direct measurement method Range Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级 A 计权最大声级 A 计权暴露声级","parameters_zh":[{"name":"范围","range":"(25-120) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 A 计权等效声级 A 计权最大声级 A 计权暴露声级 直接测量法 范围 Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a82eb94884ede9a1b2c4895","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U.2023 poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a82eb94884ede9a1b2c4896","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 120) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 120) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 120) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 120) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 120) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 120) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a82eb94884ede9a1b2c4897","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a82eb94884ede9a1b2c4898","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,3 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,3 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,3 – 50) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,3 – 50) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82eb94884ede9a1b2c4899","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a82eb94884ede9a1b2c489a","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 20) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 20) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a82eb94884ede9a1b2c489b","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a82eb94884ede9a1b2c489c","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach - oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia,","parameters":[{"name":"Zakres","range":"(0,5 – 8700) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia,\nZakres (0,5 – 8700) lx\nMetoda pomiarowa bezpośrednia","reference":"PB-01 wydanie 6 z dnia 27.02.2026 r.","norm_bases":["PB-01 wydanie 6 z dnia 27.02.2026 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach - oświetlenie elektryczne na zewnątrz Natężenie oświetlenia,\nZakres (0,5 – 8700) lx\nMetoda pomiarowa bezpośrednia PB-01 wydanie 6 z dnia 27.02.2026 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach - oswietlenie elektryczne na zewnatrz Natezenie oswietlenia,\nZakres (0,5 – 8700) lx\nMetoda pomiarowa bezposrednia PB-01 wydanie 6 z dnia 27.02.2026 r.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance,","parameters_en":[{"name":"Range","range":"(0,5 – 8700) lx"}],"search_en":"Workplace environment - indoor electric lighting - outdoor electric lighting Illuminance, Direct measurement method Range PB-01 wydanie 6 z dnia 27.02.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting - outdoor electric lighting","parameters_zh":[{"name":"范围","range":"(0,5 – 8700) lx"}],"search_zh":"直接测量法 范围 PB-01 wydanie 6 z dnia 27.02.2026 r.","technique_zh":"直接测量法"},{"_id":"6a82eb94884ede9a1b2c489d","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach - oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PB-01 wydanie 6 z dnia 27.02.2026 r.","norm_bases":["PB-01 wydanie 6 z dnia 27.02.2026 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach - oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) PB-01 wydanie 6 z dnia 27.02.2026 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach - oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen) PB-01 wydanie 6 z dnia 27.02.2026 r.","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting - outdoor electric lighting Illuminance uniformity (calculated) PB-01 wydanie 6 z dnia 27.02.2026 r.","test_object_en":"Workplace environment - indoor electric lighting - outdoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PB-01 wydanie 6 z dnia 27.02.2026 r."},{"_id":"6a82eb94884ede9a1b2c489e","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia,","parameters":[{"name":"Zakres","range":"(0,5 – 1000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia,\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia,\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5. Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia,\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance,","parameters_en":[{"name":"Range","range":"(0,5 – 1000) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance, Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) lx"}],"search_zh":"工作场所环境 — 应急照明 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a82eb94884ede9a1b2c489f","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5. Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a82eb94884ede9a1b2c48a0","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5. Srodowisko pracy - oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","test_object_en":"Workplace environment - emergency lighting","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. | PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.6; 5.2.3-5.2.6; 5.3.4-5.3.7; 5.4.2; 6; 7.1.5.","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a82eb94884ede9a1b2c48a1","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 – 45) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10,0 – 60,0) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 – 45) °C\nPrzepływ powietrza\nZakres (10,0 – 60,0) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"PB-03 wydanie 4 z dnia 08.01.2025 r.","norm_bases":["PB-03 wydanie 4 z dnia 08.01.2025 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 45) °C\nPrzepływ powietrza\nZakres (10,0 – 60,0) dm3/min\nMetoda pomiarowa bezpośrednia PB-03 wydanie 4 z dnia 08.01.2025 r. Srodowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 45) °C\nPrzeplyw powietrza\nZakres (10,0 – 60,0) dm3/min\nMetoda pomiarowa bezposrednia PB-03 wydanie 4 z dnia 08.01.2025 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 – 45) °C"},{"name":"Air flow"},{"name":"Range","range":"(10,0 – 60,0) dm3/min"}],"search_en":"Workplace environment – energy expenditure Air temperature Direct measurement method Range Air flow Range PB-03 wydanie 4 z dnia 08.01.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 – 45) °C"},{"name":"空气流量"},{"name":"范围","range":"(10,0 – 60,0) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 PB-03 wydanie 4 z dnia 08.01.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a82eb94884ede9a1b2c48a2","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PB-03 wydanie 4 z dnia 08.01.2025 r.","norm_bases":["PB-03 wydanie 4 z dnia 08.01.2025 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczeń) PB-03 wydanie 4 z dnia 08.01.2025 r. Srodowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczen) PB-03 wydanie 4 z dnia 08.01.2025 r.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment – energy expenditure Energy expenditure (calculated) PB-03 wydanie 4 z dnia 08.01.2025 r.","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） PB-03 wydanie 4 z dnia 08.01.2025 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a82eb94884ede9a1b2c48a3","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10,0 – 30,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10,0 – 35,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotność powietrza\nZakres (20,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotność powietrza\nZakres (20,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotnosc powietrza\nZakres (20,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10,0 – 30,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10,0 – 35,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(20,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10,0 – 30,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(10,0 – 35,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(20,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a82eb94884ede9a1b2c48a4","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 − 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a82eb94884ede9a1b2c48a5","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15,0 – 60,0) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) 0C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) 0C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) 0C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15,0 – 60,0) 0C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(15,0 – 60,0) 0C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a82eb94884ede9a1b2c48a6","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a82eb94884ede9a1b2c48a7","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 – 10,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30,0 – 15,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 4,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (20,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 4,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (20,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 4,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotnosc powietrza\nZakres (20,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 – 4,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 – 10,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30,0 – 15,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(20,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 4,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 – 10,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(-30,0 – 15,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(20,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 4,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a82eb94884ede9a1b2c48a8","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a82eb94884ede9a1b2c48a9","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja torakalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"thoracic fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction metals and their compounds, including inhalable fraction respirable fraction inorganic substances, including inhalable fraction thoracic fraction respirable fraction organic substances, including inhalable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"胸腔组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 无机物质，包括 可吸入组分 胸腔组分 呼吸性组分 有机物质，包括 可吸入组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82eb94884ede9a1b2c48aa","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne"},{"name":"substancje nieorganiczne"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances"},{"name":"inorganic substances"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method organic substances inorganic substances PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 有机物质 无机物质 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"有机物质"},{"name":"无机物质"}],"technique_zh":"定点测定法"},{"_id":"6a82eb94884ede9a1b2c48ab","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82eb94884ede9a1b2c48ac","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,19 – 25,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,19 – 25,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,19 – 25,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,19 – 25,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,19 – 25,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,19 – 25,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a82eb94884ede9a1b2c48ad","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,05 – 6,3) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 6,3) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,05 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust agents harmful to health- respirable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,05 – 6,3) mg/m3"}],"search_en":"Workplace environment – air Concentration of dust agents harmful to health- respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,05 – 6,3) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘"},{"_id":"6a82eb94884ede9a1b2c48ae","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 – 235,5) mg/m3"},{"name":"CO","range":"(2,0 – 203,0) ppm"},{"name":"NO","range":"(0,37 – 6,94) mg/m3"},{"name":"NO","range":"(0,3 – 5,6) ppm"},{"name":"NO2","range":"(0,11 – 11,46) mg/m3"},{"name":"NO2","range":"(0,06 – 6,00) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 – 235,5) mg/m3\nCO (2,0 – 203,0) ppm\nNO (0,37 – 6,94) mg/m3\nNO (0,3 – 5,6) ppm\nNO2 (0,11 – 11,46) mg/m3\nNO2 (0,06 – 6,00) ppm\nMetoda elektrochemiczna","reference":"PB-02 wydanie 4 z dnia 08.01.2025 r.","norm_bases":["PB-02 wydanie 4 z dnia 08.01.2025 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów\nZakres:\nCO (2,3 – 235,5) mg/m3\nCO (2,0 – 203,0) ppm\nNO (0,37 – 6,94) mg/m3\nNO (0,3 – 5,6) ppm\nNO2 (0,11 – 11,46) mg/m3\nNO2 (0,06 – 6,00) ppm\nMetoda elektrochemiczna PB-02 wydanie 4 z dnia 08.01.2025 r. Srodowisko pracy – powietrze Stezenie gazow\nZakres:\nCO (2,3 – 235,5) mg/m3\nCO (2,0 – 203,0) ppm\nNO (0,37 – 6,94) mg/m3\nNO (0,3 – 5,6) ppm\nNO2 (0,11 – 11,46) mg/m3\nNO2 (0,06 – 6,00) ppm\nMetoda elektrochemiczna PB-02 wydanie 4 z dnia 08.01.2025 r.","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 – 235,5) mg/m3"},{"name":"CO","range":"(2,0 – 203,0) ppm"},{"name":"NO","range":"(0,37 – 6,94) mg/m3"},{"name":"NO","range":"(0,3 – 5,6) ppm"},{"name":"NO2","range":"(0,11 – 11,46) mg/m3"},{"name":"NO2","range":"(0,06 – 6,00) ppm"}],"search_en":"Workplace environment – air Gas concentrations Electrochemical method CO CO NO NO NO2 NO2 PB-02 wydanie 4 z dnia 08.01.2025 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 气体浓度 电化学法 CO CO NO NO NO2 NO2 PB-02 wydanie 4 z dnia 08.01.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"CO","range":"(2,3 – 235,5) mg/m3"},{"name":"CO","range":"(2,0 – 203,0) ppm"},{"name":"NO","range":"(0,37 – 6,94) mg/m3"},{"name":"NO","range":"(0,3 – 5,6) ppm"},{"name":"NO2","range":"(0,11 – 11,46) mg/m3"},{"name":"NO2","range":"(0,06 – 6,00) ppm"}],"methodology_zh":"气体浓度"},{"_id":"6a82eb94884ede9a1b2c48af","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-02 wydanie 4 z dnia 08.01.2025 r.","norm_bases":["PB-02 wydanie 4 z dnia 08.01.2025 r."],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PB-02 wydanie 4 z dnia 08.01.2025 r. Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PB-02 wydanie 4 z dnia 08.01.2025 r.","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PB-02 wydanie 4 z dnia 08.01.2025 r.","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PB-02 wydanie 4 z dnia 08.01.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82eb94884ede9a1b2c48b0","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna w zakresie częstotliwości (10 – 100) Hz","parameters":[{"name":"Zakres","range":"1µT– 19,5 mT"}],"technique":"Metoda pomiarowa bezpośrednia (metoda uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (metoda uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości (10 – 100) Hz\nZakres 1µT– 19,5 mT\nMetoda pomiarowa bezpośrednia (metoda uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna w zakresie częstotliwości (10 – 100) Hz\nZakres 1µT– 19,5 mT\nMetoda pomiarowa bezpośrednia (metoda uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna w zakresie czestotliwosci (10 – 100) Hz\nZakres 1µT– 19,5 mT\nMetoda pomiarowa bezposrednia (metoda uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016. Nr 4 (90) s. 151 - 180","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"1µT– 19,5 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Range Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"范围","range":"1µT– 19,5 mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 范围 Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a82eb94884ede9a1b2c48b1","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości (10-100) Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości (10-100) Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego w zakresie częstotliwości (10-100) Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego w zakresie czestotliwosci (10-100) Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016. Nr 4 (90) s. 151 - 180","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range (10-100) Hz (calculated)","search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength in the frequency range (10-100) Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a82eb94884ede9a1b2c48b2","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"100 V/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz\nZakres 100 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz\nZakres 100 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego w zakresie czestotliwosci 50 Hz\nZakres 100 V/m – 30 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016. Nr 4 (90) s. 91-150","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range 50 Hz","parameters_en":[{"name":"Range","range":"100 V/m – 30 kV/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Electric field strength in the frequency range 50 Hz Direct measurement method Range Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"范围","range":"100 V/m – 30 kV/m"}],"search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 50 Hz 频率范围内的电场强度 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场","methodology_zh":"50 Hz 频率范围内的电场强度"},{"_id":"6a82eb94884ede9a1b2c48b3","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna w zakresie częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"1 µT– 19,5 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości 50 Hz\nZakres 1 µT– 19,5 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna w zakresie częstotliwości 50 Hz\nZakres 1 µT– 19,5 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna w zakresie czestotliwosci 50 Hz\nZakres 1 µT– 19,5 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016. Nr 4 (90) s. 91-150","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density in the frequency range 50 Hz","parameters_en":[{"name":"Range","range":"1 µT– 19,5 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic flux density in the frequency range 50 Hz Direct measurement method Range Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"范围","range":"1 µT– 19,5 mT"}],"search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 50 Hz 频率范围内的磁感应强度 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场","methodology_zh":"50 Hz 频率范围内的磁感应强度"},{"_id":"6a82eb94884ede9a1b2c48b4","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego w zakresie czestotliwosci 50 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016. Nr 4 (90) s. 91-150","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range 50 Hz (calculated)","search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic field strength in the frequency range 50 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 50 Hz 频率范围内的磁场强度（由计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150","test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场","methodology_zh":"50 Hz 频率范围内的磁场强度（由计算得出）"},{"_id":"6a82eb94884ede9a1b2c48b5","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości 100 kHz - 6 GHz","parameters":[{"name":"Zakres","range":"(2 – 800) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości 100 kHz - 6 GHz\nZakres (2 – 800) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych Natężenie pola elektrycznego w zakresie częstotliwości 100 kHz - 6 GHz\nZakres (2 – 800) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiotelekomunikacyjnych Natezenie pola elektrycznego w zakresie czestotliwosci 100 kHz - 6 GHz\nZakres (2 – 800) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92) s. 89 - 131","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(2 – 800) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems Direct measurement method Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems","parameters_zh":[{"name":"范围","range":"(2 – 800) V/m"}],"search_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场"},{"_id":"6a82eb94884ede9a1b2c48b6","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz","parameters":[{"name":"Zakres","range":"(0,01 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiotelekomunikacyjnych Natezenie pola magnetycznego w zakresie czestotliwosci 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92) s. 89 - 131","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,01 – 16) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems Direct measurement method Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems","parameters_zh":[{"name":"范围","range":"(0,01 – 16) A/m"}],"search_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场"},{"_id":"6a82eb94884ede9a1b2c48b7","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 800 MHz – 6 GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 800 MHz – 6 GHz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiotelekomunikacyjnych Natężenie pola magnetycznego w zakresie częstotliwości 800 MHz – 6 GHz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiotelekomunikacyjnych Natezenie pola magnetycznego w zakresie czestotliwosci 800 MHz – 6 GHz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92) s. 89 - 131","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range 800 MHz – 6 GHz (calculated)","search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems Magnetic field strength in the frequency range 800 MHz – 6 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiotelecommunication systems","search_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131","test_object_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场"},{"_id":"6a82eb94884ede9a1b2c48b8","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości 10 Hz – 400 kHz","parameters":[{"name":"Zakres","range":"2 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości 100 kHz – 6 GHz"},{"name":"Zakres","range":"2 V/m – 800 V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości 10 Hz – 400 kHz\nZakres:\nZakres 2 V/m – 50 kV/m\nw zakresie częstotliwości 100 kHz – 6 GHz\nZakres 2 V/m – 800 V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002","norm_bases":["PN-T-06580-3:2002"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Natężenie pola elektrycznego w zakresie częstotliwości 10 Hz – 400 kHz\nZakres:\nZakres 2 V/m – 50 kV/m\nw zakresie częstotliwości 100 kHz – 6 GHz\nZakres 2 V/m – 800 V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Pole elektromagnetyczne Natezenie pola elektrycznego w zakresie czestotliwosci 10 Hz – 400 kHz\nZakres:\nZakres 2 V/m – 50 kV/m\nw zakresie czestotliwosci 100 kHz – 6 GHz\nZakres 2 V/m – 800 V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"2 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości 100 kHz – 6 GHz"},{"name":"Range","range":"2 V/m – 800 V/m"}],"search_en":"Electromagnetic field Direct measurement method Range Range PN-T-06580-3:2002","technique_en":"Direct measurement method","test_object_en":"Electromagnetic field","parameters_zh":[{"name":"范围","range":"2 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości 100 kHz – 6 GHz"},{"name":"范围","range":"2 V/m – 800 V/m"}],"search_zh":"电磁场 直接测量法 范围 范围 PN-T-06580-3:2002","technique_zh":"直接测量法","test_object_zh":"电磁场"},{"_id":"6a82eb94884ede9a1b2c48b9","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 10 Hz – 400 kHz"},{"name":"Zakres","range":"1 µT– 19,5 mT"},{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"0,2 mT– 1200 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 10 Hz – 400 kHz\nZakres 1 µT– 19,5 mT\nw zakresie częstotliwości 0 Hz\nZakres 0,2 mT– 1200 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002","norm_bases":["PN-T-06580-3:2002"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 10 Hz – 400 kHz\nZakres 1 µT– 19,5 mT\nw zakresie częstotliwości 0 Hz\nZakres 0,2 mT– 1200 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Pole elektromagnetyczne Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 10 Hz – 400 kHz\nZakres 1 µT– 19,5 mT\nw zakresie czestotliwosci 0 Hz\nZakres 0,2 mT– 1200 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"w zakresie częstotliwości 10 Hz – 400 kHz"},{"name":"Range","range":"1 µT– 19,5 mT"},{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"0,2 mT– 1200 mT"}],"search_en":"Electromagnetic field Magnetic flux density: Direct measurement method Range in the frequency range 0 Hz Range PN-T-06580-3:2002","technique_en":"Direct measurement method","test_object_en":"Electromagnetic field","parameters_zh":[{"name":"w zakresie częstotliwości 10 Hz – 400 kHz"},{"name":"范围","range":"1 µT– 19,5 mT"},{"name":"频率范围 0 Hz"},{"name":"范围","range":"0,2 mT– 1200 mT"}],"search_zh":"电磁场 磁感应强度： 直接测量法 范围 频率范围 0 Hz 范围 PN-T-06580-3:2002","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"电磁场"},{"_id":"6a82eb94884ede9a1b2c48ba","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz","parameters":[{"name":"Zakres","range":"(0,01 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002","norm_bases":["PN-T-06580-3:2002"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci 100 kHz – 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,01 – 16) A/m"}],"search_en":"Electromagnetic field Direct measurement method Range PN-T-06580-3:2002","technique_en":"Direct measurement method","test_object_en":"Electromagnetic field","parameters_zh":[{"name":"范围","range":"(0,01 – 16) A/m"}],"search_zh":"电磁场 直接测量法 范围 PN-T-06580-3:2002","technique_zh":"直接测量法","test_object_zh":"电磁场"},{"_id":"6a82eb94884ede9a1b2c48bb","lab_id":"69ad52a3de79e566650fb8ab","country":"PL","accr_number":"AB 1648","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 10 Hz – 400 kHz 800 MHz – 6 GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 10 Hz – 400 kHz 800 MHz – 6 GHz (z obliczeń)","reference":"PN-T-06580-3:2002","norm_bases":["PN-T-06580-3:2002"],"lab_section":"Laboratorium Badań Środowiska; Aleja Walentego Roździeńskiego 91, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości 10 Hz – 400 kHz 800 MHz – 6 GHz (z obliczeń) PN-T-06580-3:2002 Pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci 10 Hz – 400 kHz 800 MHz – 6 GHz (z obliczen) PN-T-06580-3:2002","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range 10 Hz – 400 kHz 800 MHz – 6 GHz (calculated)","search_en":"Electromagnetic field Magnetic field strength in the frequency range 10 Hz – 400 kHz 800 MHz – 6 GHz (calculated) PN-T-06580-3:2002","test_object_en":"Electromagnetic field","search_zh":"电磁场 PN-T-06580-3:2002","test_object_zh":"电磁场"}],"has_pdf":true}