{"lab":{"_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","address":"ul. bp. Bernarda Bogedaina 3, 50-514 Wrocław","categories":["environment","materials"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":325,"name":"ENVILAB-EKO Norbert Dąbrowski","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1642.pdf"],"scope_summary":"","search_text":"envilab-eko norbert dąbrowski ul. bp. bernarda bogedaina 3, 50-514 wrocław environment other materials construction electronics pharma metrology petro automotive food","status":"active","updated_at":"2026-03-08T14:50:46.802Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:05:32.043Z","email_confidence":"high","email_mx":true,"email_source":"https://envilab-eko.com/kontakt/","parse_date":"2026-08-17T11:05:32.043Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/35","pl":"Badania akustyczne drgań – pomieszczenia (warunki środowiskowe)","en":"Acoustic and vibration tests – facilities (environmental conditions)"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"C/35/P","pl":"Badania chemiczne i pobieranie próbek – pomieszczenia (warunki środowiskowe)","en":"Chemical tests and sampling – facilities (environmental conditions)"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, drgania, mikroklimat, wydatek energetyczny, nielaserowe promieniowanie optyczne, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors – noise, ultrasonic noise, lighting, vibration, microclimate, energy expenditure, non-laser optical radiation, electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"23","date":"28.07.2026"},"map_coord":[51.081827,17.066728],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/0655a9177ed88e5f6f6fd95ce783c077/AB%201642.pdf","has_en":true,"category_counts":{"environment":207,"other":114,"materials":14,"construction":2,"petro":1,"automotive":1},"category_scores":{"environment":126.4,"other":38.34,"materials":0.58,"construction":0.01,"petro":0,"automotive":0},"has_zh":true},"methods":[{"_id":"6a82eafc884ede9a1b2c46ed","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na: − czynniki pyłowe","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna − metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna − substancje organiczne, w tym"},{"name":"frakcja wdychalna − substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja torakalna"},{"name":"frakcja respirabilna − respirabilne sztuczne włókna mineralne − respirabilne włókna azbestu"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na: − czynniki pyłowe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna − metale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna − substancje organiczne, w tym\nfrakcja wdychalna − substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna − respirabilne sztuczne włókna mineralne − respirabilne włókna azbestu\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek w celu oceny narażenia zawodowego na: − czynniki pyłowe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna − metale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna − substancje organiczne, w tym\nfrakcja wdychalna − substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna − respirabilne sztuczne włókna mineralne − respirabilne włókna azbestu\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek w celu oceny narazenia zawodowego na: − czynniki pylowe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna − metale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna − substancje organiczne, w tym\nfrakcja wdychalna − substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja torakalna\nfrakcja respirabilna − respirabilne sztuczne wlokna mineralne − respirabilne wlokna azbestu\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction − metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction − organic substances, including"},{"name":"inhalable fraction − inorganic substances, including"},{"name":"inhalable fraction"},{"name":"thoracic fraction"},{"name":"frakcja respirabilna − respirabilne sztuczne włókna mineralne − respirabilne włókna azbestu"}],"search_en":"Workplace environment − air Personal dosimetry method inhalable fraction respirable fraction − metals and their compounds, including inhalable fraction respirable fraction − organic substances, including inhalable fraction − inorganic substances, including inhalable fraction thoracic fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"可吸入组分"},{"name":"frakcja respirabilna − metale i ich związki, w tym"},{"name":"可吸入组分"},{"name":"呼吸性粉尘 － 有机物质，其中包括"},{"name":"frakcja wdychalna − substancje nieorganiczne, w tym"},{"name":"可吸入组分"},{"name":"胸腔组分"},{"name":"frakcja respirabilna − respirabilne sztuczne włókna mineralne − respirabilne włókna azbestu"}],"search_zh":"工作环境 − 空气 个体剂量测定法 可吸入组分 可吸入组分 呼吸性粉尘 － 有机物质，其中包括 可吸入组分 胸腔组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a82eafc884ede9a1b2c46ee","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na: − substancje organiczne − substancje nieorganiczne, w tym","parameters":[{"name":"frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na: − substancje organiczne − substancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek w celu oceny narażenia zawodowego na: − substancje organiczne − substancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek w celu oceny narazenia zawodowego na: − substancje organiczne − substancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"}],"search_en":"Workplace environment − air Stationary method inhalable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"可吸入组分"}],"search_zh":"工作环境 − 空气 定点测定法 可吸入组分 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气","technique_zh":"定点测定法"},{"_id":"6a82eafc884ede9a1b2c46ef","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a82eafc884ede9a1b2c46f0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"asfalt naftowy"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,10 – 17,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,10 – 17,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,10 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,10 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"petroleum bitumen"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"Range","range":"(0,10 – 17,0) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"石油沥青"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,10 – 17,0) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 石油沥青 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a82eafc884ede9a1b2c46f1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"spaliny silnika Diesla"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 15,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 15,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 15,4) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nspaliny silnika Diesla\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,09 – 15,4) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"diesel engine exhaust"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,09 – 15,4) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"柴油机排气"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,09 – 15,4) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 柴油机排气 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a82eafc884ede9a1b2c46f2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie gazów:","parameters":[{"name":"CO","range":"(2,5 – 117) mg/m3"},{"name":"Zakres","range":"(2,0 – 100) ppm"},{"name":"NO","range":"(0,13 – 6,25) mg/m3"},{"name":"(0,1 – 5,0) ppm"},{"name":"NO2","range":"(0,19 – 2,3) mg/m3"},{"name":"(0,1 – 1,2) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów:\nZakres:\nCO (2,5 – 117) mg/m3\nZakres (2,0 – 100) ppm\nNO (0,13 – 6,25) mg/m3\n(0,1 – 5,0) ppm\nNO2 (0,19 – 2,3) mg/m3\n(0,1 – 1,2) ppm\nMetoda elektrochemiczna","reference":"EV-PB-1 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-1 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie gazów:\nZakres:\nCO (2,5 – 117) mg/m3\nZakres (2,0 – 100) ppm\nNO (0,13 – 6,25) mg/m3\n(0,1 – 5,0) ppm\nNO2 (0,19 – 2,3) mg/m3\n(0,1 – 1,2) ppm\nMetoda elektrochemiczna EV-PB-1 wydanie 2 z dnia 01.04.2021 r. Srodowisko pracy − powietrze Stezenie gazow:\nZakres:\nCO (2,5 – 117) mg/m3\nZakres (2,0 – 100) ppm\nNO (0,13 – 6,25) mg/m3\n(0,1 – 5,0) ppm\nNO2 (0,19 – 2,3) mg/m3\n(0,1 – 1,2) ppm\nMetoda elektrochemiczna EV-PB-1 wydanie 2 z dnia 01.04.2021 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations:","parameters_en":[{"name":"CO","range":"(2,5 – 117) mg/m3"},{"name":"Range","range":"(2,0 – 100) ppm"},{"name":"NO","range":"(0,13 – 6,25) mg/m3"},{"name":"(0,1 – 5,0) ppm"},{"name":"NO2","range":"(0,19 – 2,3) mg/m3"},{"name":"(0,1 – 1,2) ppm"}],"search_en":"Workplace environment − air Gas concentrations: Electrochemical method CO Range NO NO2 EV-PB-1 wydanie 2 z dnia 01.04.2021 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"CO","range":"(2,5 – 117) mg/m3"},{"name":"范围","range":"(2,0 – 100) ppm"},{"name":"NO","range":"(0,13 – 6,25) mg/m3"},{"name":"(0,1 – 5,0) ppm"},{"name":"NO2","range":"(0,19 – 2,3) mg/m3"},{"name":"(0,1 – 1,2) ppm"}],"search_zh":"工作环境 − 空气 气体浓度： 电化学法 CO 范围 NO NO2 EV-PB-1 wydanie 2 z dnia 01.04.2021 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"气体浓度："},{"_id":"6a82eafc884ede9a1b2c46f3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie ditlenku węgla","parameters":[{"name":"Zakres","range":"(900 - 36000) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie ditlenku węgla\nZakres (900 - 36000) mg/m3\nMetoda elektrochemiczna","reference":"EV-PB-12 wydanie 2 z dnia 22.02.2022 r.","norm_bases":["EV-PB-12 wydanie 2 z dnia 22.02.2022 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie ditlenku węgla\nZakres (900 - 36000) mg/m3\nMetoda elektrochemiczna EV-PB-12 wydanie 2 z dnia 22.02.2022 r. Srodowisko pracy − powietrze Stezenie ditlenku wegla\nZakres (900 - 36000) mg/m3\nMetoda elektrochemiczna EV-PB-12 wydanie 2 z dnia 22.02.2022 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(900 - 36000) mg/m3"}],"search_en":"Workplace environment − air Carbon dioxide concentration Electrochemical method Range EV-PB-12 wydanie 2 z dnia 22.02.2022 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(900 - 36000) mg/m3"}],"search_zh":"工作环境 − 空气 二氧化碳浓度 电化学法 范围 EV-PB-12 wydanie 2 z dnia 22.02.2022 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化碳浓度"},{"_id":"6a82eafc884ede9a1b2c46f4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 - 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30 - 135) dB\nSzczytowy poziom dzwieku C\nZakres (40 - 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(30 - 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 - 137) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30 - 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 - 137) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a82eafc884ede9a1b2c46f5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment − noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a82eafc884ede9a1b2c46f6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(49 - 158) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (49 - 158) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (49 - 158) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (49 - 158) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(49 - 158) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(49 - 158) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a82eafc884ede9a1b2c46f7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a82eafc884ede9a1b2c46f8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22 – 135) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 噪声"},{"_id":"6a82eafc884ede9a1b2c46f9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej − halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings − noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住与公共建筑内的房间 － 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 噪声"},{"_id":"6a82eafc884ede9a1b2c46fa","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wylaczeniem punktu F","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 - 135) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82eafc884ede9a1b2c46fb","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami, LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wylaczeniem punktu F","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. t.j. Dz.U. 2023 poz. 1706 z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82eafc884ede9a1b2c46fc","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 10) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 10) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 10) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a82eafc884ede9a1b2c46fd","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a82eafc884ede9a1b2c46fe","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,56 – 60) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,56 – 60) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,56 – 60) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,56 – 60) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,56 – 60) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,56 – 60) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82eafc884ede9a1b2c46ff","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82eafc884ede9a1b2c4700","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 - 60) o C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 - 60) o C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 - 60) o C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 - 60) o C\nTemperatura wilgotna naturalna\nZakres (15 - 60) o C\nTemperatura poczernionej kuli\nZakres (15 - 60) o C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 - 60) o C\nTemperatura wilgotna naturalna\nZakres (15 - 60) o C\nTemperatura poczernionej kuli\nZakres (15 - 60) o C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 - 60) o C\nTemperatura wilgotna naturalna\nZakres (15 - 60) o C\nTemperatura poczernionej kuli\nZakres (15 - 60) o C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 - 60) o C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 - 60) o C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 - 60) o C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 - 60) o C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 - 60) o C"},{"name":"黑球温度"},{"name":"范围","range":"(15 - 60) o C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a82eafc884ede9a1b2c4701","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a82eafc884ede9a1b2c4702","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(- 30,0 - 10,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(- 30,0 - 10,0) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (- 30,0 - 10,0) °C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (- 30,0 - 10,0) °C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (- 30,0 - 10,0) °C\nWilgotnosc powietrza\nZakres (20 - 90) %\nPredkosc powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(- 30,0 - 10,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(- 30,0 - 10,0) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(- 30,0 - 10,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(- 30,0 - 10,0) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a82eafc884ede9a1b2c4703","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik tWC (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, tWC index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, tWC index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、tWC 指数（由计算得出） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、tWC 指数（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c4704","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) o C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) o C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) o C\nTemperatura poczernionej kuli\nZakres (10 - 40) o C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 +Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006 +Ap2:2016-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) o C\nTemperatura poczernionej kuli\nZakres (10 - 40) o C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 +Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) o C\nTemperatura poczernionej kuli\nZakres (10 - 40) o C\nWilgotnosc powietrza\nZakres (20 - 90) %\nPredkosc powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 +Ap2:2016-04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) o C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 40) o C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1,0) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 +Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) o C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 40) o C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 +Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82eafc884ede9a1b2c4705","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 +Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006 +Ap2:2016-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 +Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 +Ap2:2016-04","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 +Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 +Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82eafc884ede9a1b2c4706","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 - 40) ̊C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 - 60) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 - 40) ̊C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","norm_bases":["EV-PB-8 wydanie 3 z dnia 18.05.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 - 40) ̊C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia EV-PB-8 wydanie 3 z dnia 18.05.2021 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 - 40) C\nPrzeplyw powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezposrednia EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 - 40) ̊C"},{"name":"Air flow"},{"name":"Range","range":"(10 - 60) dm3/min"}],"search_en":"Workplace environment - energy expenditure Air temperature Direct measurement method Range Air flow Range EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 - 40) ̊C"},{"name":"空气流量"},{"name":"范围","range":"(10 - 60) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a82eafc884ede9a1b2c4707","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","norm_bases":["EV-PB-8 wydanie 3 z dnia 18.05.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) EV-PB-8 wydanie 3 z dnia 18.05.2021 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated) EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） EV-PB-8 wydanie 3 z dnia 18.05.2021 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a82eafc884ede9a1b2c4708","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","norm_bases":["PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 - 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 - 10000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 - 10000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a82eafc884ede9a1b2c4709","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","norm_bases":["PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 EV-PB-2 wydanie 1 z dnia 02.01.2017 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a82eafc884ede9a1b2c470a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 10000) lx"}],"search_en":"Workplace environment − outdoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment − outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10000) lx"}],"search_zh":"工作环境 － 室外电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作环境 － 室外电气照明"},{"_id":"6a82eafc884ede9a1b2c470b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment − outdoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 室外电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作环境 － 室外电气照明"},{"_id":"6a82eafc884ede9a1b2c470c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 - 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A Srodowisko pracy − oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 - 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 500) lx"}],"search_en":"Workplace environment − emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 500) lx"}],"search_zh":"工作环境 － 应急照明 照度 直接测量法 范围 PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a82eafc884ede9a1b2c470d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A Srodowisko pracy − oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2025-05 z wylaczeniem punktow: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作环境 － 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a82eafc884ede9a1b2c470e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Czas załączenia oświetlenia awaryjnego","parameters":[{"name":"Zakres","range":"(1 - 80) s"}],"technique":null,"techniques":[],"computed":[],"activity":"Czas załączenia oświetlenia awaryjnego\nZakres (1 - 80) s","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Czas załączenia oświetlenia awaryjnego\nZakres (1 - 80) s PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A Srodowisko pracy − oswietlenie awaryjne Czas zalaczenia oswietlenia awaryjnego\nZakres (1 - 80) s PN-EN 1838:2025-05 z wylaczeniem punktow: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1 - 80) s"}],"search_en":"Workplace environment − emergency lighting Range PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","test_object_en":"Workplace environment − emergency lighting","parameters_zh":[{"name":"范围","range":"(1 - 80) s"}],"search_zh":"工作环境 － 应急照明 范围 PN-EN 1838:2025-05 z wyłączeniem punktów: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7 Metoda A","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a82eafc884ede9a1b2c470f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 ÷ 400) nm","parameters":[{"name":"Zakres","range":"(0,10x10-3 – 39,99) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda A)","techniques":["Metoda pomiarowa bezpośrednia (metoda A)"],"computed":[],"activity":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 ÷ 400) nm\nZakres (0,10x10-3 – 39,99) W/m2\nMetoda pomiarowa bezpośrednia (metoda A)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 ÷ 400) nm\nZakres (0,10x10-3 – 39,99) W/m2\nMetoda pomiarowa bezpośrednia (metoda A) PN-EN 14255-1:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 ÷ 400) nm\nZakres (0,10x10-3 – 39,99) W/m2\nMetoda pomiarowa bezposrednia (metoda A) PN-EN 14255-1:2010","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance UVA, UVB and UVC in the spectral range (180 ÷ 400) nm","parameters_en":[{"name":"Range","range":"(0,10x10-3 – 39,99) W/m2"}],"search_en":"Workplace environment − non-laser optical radiation Effective irradiance UVA, UVB and UVC in the spectral range (180 ÷ 400) nm Direct measurement method (method A) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method A)","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(0,10x10-3 – 39,99) W/m2"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法（方法 A） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 − 非激光光辐射","technique_zh":"直接测量法（方法 A）"},{"_id":"6a82eafc884ede9a1b2c4710","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczne napromienienie ultrafioletem niebezpiecznym w zakresie spektralnym (180 ÷ 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne napromienienie ultrafioletem niebezpiecznym w zakresie spektralnym (180 ÷ 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczne napromienienie ultrafioletem niebezpiecznym w zakresie spektralnym (180 ÷ 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczne napromienienie ultrafioletem niebezpiecznym w zakresie spektralnym (180 ÷ 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiant exposure to hazardous ultraviolet in the spectral range (180 ÷ 400) nm (calculated)","search_en":"Workplace environment − non-laser optical radiation Effective radiant exposure to hazardous ultraviolet in the spectral range (180 ÷ 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c4711","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia promieniowaniem UVA w zakresie spektralnym (315 ÷ 400) nm","parameters":[{"name":"Zakres","range":"(0,010 – 3,999x103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda M)","techniques":["Metoda pomiarowa bezpośrednia (metoda M)"],"computed":[],"activity":"Natężenie napromienienia promieniowaniem UVA w zakresie spektralnym (315 ÷ 400) nm\nZakres (0,010 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia (metoda M)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Natężenie napromienienia promieniowaniem UVA w zakresie spektralnym (315 ÷ 400) nm\nZakres (0,010 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia (metoda M) PN-EN 14255-1:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Natezenie napromienienia promieniowaniem UVA w zakresie spektralnym (315 ÷ 400) nm\nZakres (0,010 – 3,999x103) W/m2\nMetoda pomiarowa bezposrednia (metoda M) PN-EN 14255-1:2010","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 3,999x103) W/m2"}],"search_en":"Workplace environment − non-laser optical radiation Direct measurement method (method M) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method M)","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(0,010 – 3,999x103) W/m2"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法（方法 M） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 − 非激光光辐射","technique_zh":"直接测量法（方法 M）"},{"_id":"6a82eafc884ede9a1b2c4712","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Napromienienie promieniowania UVA w zakresie spektralnym (315 ÷ 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie promieniowania UVA w zakresie spektralnym (315 ÷ 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Napromienienie promieniowania UVA w zakresie spektralnym (315 ÷ 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Napromienienie promieniowania UVA w zakresie spektralnym (315 ÷ 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure of UVA radiation in the spectral range (315 ÷ 400) nm (calculated)","search_en":"Workplace environment − non-laser optical radiation Radiant exposure of UVA radiation in the spectral range (315 ÷ 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c4713","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300÷700) nm","parameters":[{"name":"Zakres","range":"(1x10-3 – 399,9)"}],"technique":"Metoda pomiarowa bezpośrednia (metoda O)","techniques":["Metoda pomiarowa bezpośrednia (metoda O)"],"computed":[],"activity":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300÷700) nm\nZakres (1x10-3 – 399,9)\nMetoda pomiarowa bezpośrednia (metoda O)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300÷700) nm\nZakres (1x10-3 – 399,9)\nMetoda pomiarowa bezpośrednia (metoda O) PN-EN 14255-2:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia VIS w zakresie spektralnym (300÷700) nm\nZakres (1x10-3 – 399,9)\nMetoda pomiarowa bezposrednia (metoda O) PN-EN 14255-2:2010","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance VIS in the spectral range (300÷700) nm","parameters_en":[{"name":"Range","range":"(1x10-3 – 399,9)"}],"search_en":"Workplace environment − non-laser optical radiation Effective irradiance VIS in the spectral range (300÷700) nm Direct measurement method (method O) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method O)","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(1x10-3 – 399,9)"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法（方法 O） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 − 非激光光辐射","technique_zh":"直接测量法（方法 O）"},{"_id":"6a82eafc884ede9a1b2c4714","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300÷700) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300÷700) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300÷700) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300÷700) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance of VIS radiation in the spectral range (300÷700) nm (calculated)","search_en":"Workplace environment − non-laser optical radiation Effective radiance of VIS radiation in the spectral range (300÷700) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 (300÷700) nm 光谱范围内可见光辐射的有效辐亮度（由计算得出） PN-EN 14255-2:2010","test_object_zh":"工作场所环境 − 非激光光辐射","methodology_zh":"(300÷700) nm 光谱范围内可见光辐射的有效辐亮度（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c4715","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 ÷ 3000) nm","parameters":[{"name":"Zakres","range":"(1 – 3999) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda X)","techniques":["Metoda pomiarowa bezpośrednia (metoda X)"],"computed":[],"activity":"Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 ÷ 3000) nm\nZakres (1 – 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda X)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 ÷ 3000) nm\nZakres (1 – 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda X) PN-EN 14255-2:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Natezenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 ÷ 3000) nm\nZakres (1 – 3999) W/m2\nMetoda pomiarowa bezposrednia (metoda X) PN-EN 14255-2:2010","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of VIS, IRA and IRB in the spectral range (380 ÷ 3000) nm","parameters_en":[{"name":"Range","range":"(1 – 3999) W/m2"}],"search_en":"Workplace environment − non-laser optical radiation Irradiance of VIS, IRA and IRB in the spectral range (380 ÷ 3000) nm Direct measurement method (method X) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method X)","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(1 – 3999) W/m2"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法（方法 X） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 − 非激光光辐射","technique_zh":"直接测量法（方法 X）"},{"_id":"6a82eafc884ede9a1b2c4716","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Napromienienie dla VIS, IRA, IRB w zakresie spektralnym (380 ÷ 3000) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie dla VIS, IRA, IRB w zakresie spektralnym (380 ÷ 3000) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Napromienienie dla VIS, IRA, IRB w zakresie spektralnym (380 ÷ 3000) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy − nielaserowe promieniowanie optyczne Napromienienie dla VIS, IRA, IRB w zakresie spektralnym (380 ÷ 3000) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure for VIS, IRA, IRB in the spectral range (380 ÷ 3000) nm (calculated)","search_en":"Workplace environment − non-laser optical radiation Radiant exposure for VIS, IRA, IRB in the spectral range (380 ÷ 3000) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c4717","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym (380÷1400) nm","parameters":[{"name":"Zakres","range":"(1x10-3 – 3,999x103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym (380÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687:2002, pkt. 2.5.4","norm_bases":["PN-T-05687:2002, pkt. 2.5.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym (380÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687:2002, pkt. 2.5.4 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla VIS, IRA w zakresie spektralnym (380÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687:2002, pkt. 2.5.4","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1x10-3 – 3,999x103) W/m2"}],"search_en":"Workplace environment − non-laser optical radiation Direct measurement method Range PN-T-05687:2002, pkt. 2.5.4","technique_en":"Direct measurement method","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(1x10-3 – 3,999x103) W/m2"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法 范围 PN-T-05687:2002, pkt. 2.5.4","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c4718","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna dla, VIS, IRA w zakresie spektralnym (380÷1400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna dla, VIS, IRA w zakresie spektralnym (380÷1400) nm (z obliczeń)","reference":"PN-T-05687:2002, pkt. 2.5.4","norm_bases":["PN-T-05687:2002, pkt. 2.5.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla, VIS, IRA w zakresie spektralnym (380÷1400) nm (z obliczeń) PN-T-05687:2002, pkt. 2.5.4 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla, VIS, IRA w zakresie spektralnym (380÷1400) nm (z obliczen) PN-T-05687:2002, pkt. 2.5.4","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment − non-laser optical radiation PN-T-05687:2002, pkt. 2.5.4","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 PN-T-05687:2002, pkt. 2.5.4","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c4719","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym (780÷1400) nm","parameters":[{"name":"Zakres","range":"(1x10-3 – 3,999x103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym (780÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687:2002, pkt. 2.5.4","norm_bases":["PN-T-05687:2002, pkt. 2.5.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym (780÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687:2002, pkt. 2.5.4 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla IRA w zakresie spektralnym (780÷1400) nm\nZakres (1x10-3 – 3,999x103) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687:2002, pkt. 2.5.4","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1x10-3 – 3,999x103) W/m2"}],"search_en":"Workplace environment − non-laser optical radiation Direct measurement method Range PN-T-05687:2002, pkt. 2.5.4","technique_en":"Direct measurement method","test_object_en":"Workplace environment − non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(1x10-3 – 3,999x103) W/m2"}],"search_zh":"工作场所环境 − 非激光光辐射 直接测量法 范围 PN-T-05687:2002, pkt. 2.5.4","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c471a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna dla, IRA w zakresie spektralnym (780÷1400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna dla, IRA w zakresie spektralnym (780÷1400) nm (z obliczeń)","reference":"PN-T-05687:2002, pkt. 2.5.4","norm_bases":["PN-T-05687:2002, pkt. 2.5.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla, IRA w zakresie spektralnym (780÷1400) nm (z obliczeń) PN-T-05687:2002, pkt. 2.5.4 Srodowisko pracy − nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla, IRA w zakresie spektralnym (780÷1400) nm (z obliczen) PN-T-05687:2002, pkt. 2.5.4","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment − non-laser optical radiation PN-T-05687:2002, pkt. 2.5.4","test_object_en":"Workplace environment − non-laser optical radiation","search_zh":"工作场所环境 − 非激光光辐射 PN-T-05687:2002, pkt. 2.5.4","test_object_zh":"工作场所环境 − 非激光光辐射"},{"_id":"6a82eafc884ede9a1b2c471b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola elektrycznego w paśmie częstotliwości: 10 Hz – 400 kHz 1 GHz – 3 GHz","parameters":[{"name":"Zakres","range":"(1– 350) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w paśmie częstotliwości: 10 Hz – 400 kHz 1 GHz – 3 GHz\nZakres (1– 350) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","norm_bases":["PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola elektrycznego w paśmie częstotliwości: 10 Hz – 400 kHz 1 GHz – 3 GHz\nZakres (1– 350) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r. Srodowisko pracy - pole elektromagnetyczne Natezenie pola elektrycznego w pasmie czestotliwosci: 10 Hz – 400 kHz 1 GHz – 3 GHz\nZakres (1– 350) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1– 350) V/m"}],"search_en":"Workplace environment - electromagnetic field Direct measurement method Range PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"(1– 350) V/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 范围 PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a82eafc884ede9a1b2c471c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: 10Hz - 400kHz","parameters":[{"name":"Zakres","range":"(4 – 8000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: 10Hz - 400kHz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","norm_bases":["PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości: 10Hz - 400kHz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r. Srodowisko pracy - pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci: 10Hz - 400kHz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(4 – 8000) A/m"}],"search_en":"Workplace environment - electromagnetic field Direct measurement method Range PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"(4 – 8000) A/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 范围 PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a82eafc884ede9a1b2c471d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 1 GHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 GHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","norm_bases":["PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 GHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r. Srodowisko pracy - pole elektromagnetyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 GHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 1 GHz","range":"do 3 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field Magnetic field strength: in the frequency range from 1 GHz (calculated) PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","test_object_en":"Workplace environment - electromagnetic field","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 1 GHz 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 电磁场 磁场强度： 频率范围自 1 GHz 起 （计算得出） PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a82eafc884ede9a1b2c471e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: 0 Hz","parameters":[{"name":"Zakres","range":"4 A/m – 800 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: 0 Hz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","norm_bases":["PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości: 0 Hz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r. Srodowisko pracy - pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci: 0 Hz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"4 A/m – 800 kA/m"}],"search_en":"Workplace environment - electromagnetic field Direct measurement method Range PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"4 A/m – 800 kA/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 范围 PN-T-06580-3:2002 EV-PB-15 wydanie 1 z dnia 18.12.2023 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a82eafc884ede9a1b2c471f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości 20 Hz – 50 Hz"},{"name":"Zakres","range":"(4 – 8000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 20 Hz – 50 Hz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 20 Hz – 50 Hz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 20 Hz – 50 Hz\nZakres (4 – 8000) A/m\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"w zakresie częstotliwości 20 Hz – 50 Hz"},{"name":"Range","range":"(4 – 8000) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength: Direct measurement method (simplified) Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości 20 Hz – 50 Hz"},{"name":"范围","range":"(4 – 8000) A/m"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁场强度： 直接测量法（简化） 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）"},{"_id":"6a82eafc884ede9a1b2c4720","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzącej od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: 10 - 400 kHz","parameters":[{"name":"Zakres","range":"100 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: 10 - 400 kHz\nZakres 100 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","norm_bases":["Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzącej od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego w zakresie częstotliwości: 10 - 400 kHz\nZakres 100 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzacej od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego w zakresie czestotliwosci: 10 - 400 kHz\nZakres 100 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Ocen Srodowiska Pracy 2016. Nr 4 (90) s. 91-150","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"100 V/m – 50 kV/m"}],"search_en":"Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Direct measurement method Range Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"范围","range":"100 V/m – 50 kV/m"}],"search_zh":"直接测量法 范围 Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_zh":"直接测量法"},{"_id":"6a82eafc884ede9a1b2c4721","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzącej od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 10 - 400 kHz","parameters":[{"name":"Zakres","range":"4 A/m – 800 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 10 - 400 kHz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","norm_bases":["Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzącej od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego w zakresie częstotliwości 10 - 400 kHz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzacej od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego w zakresie czestotliwosci 10 - 400 kHz\nZakres 4 A/m – 800 kA/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Ocen Srodowiska Pracy 2016. Nr 4 (90) s. 91-150","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"4 A/m – 800 kA/m"}],"search_en":"Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Direct measurement method Range Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"范围","range":"4 A/m – 800 kA/m"}],"search_zh":"直接测量法 范围 Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150","technique_zh":"直接测量法"},{"_id":"6a82eafc884ede9a1b2c4722","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,2 - 60) mg/m3"},{"name":"Zakres","range":"(0,006 - 0,3) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,2 - 60) mg/m3\nZakres (0,006 - 0,3) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-71-Z-04041","norm_bases":["PN-Z-71-Z-04041"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość amoniaku\nZakres:\nZakres (1,2 - 60) mg/m3\nZakres (0,006 - 0,3) mg w próbce\nMetoda spektrofotometryczna PN-Z-71-Z-04041 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,2 - 60) mg/m3\nZakres (0,006 - 0,3) mg w probce\nMetoda spektrofotometryczna PN-Z-71-Z-04041","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(1,2 - 60) mg/m3"},{"name":"Range","range":"(0,006 - 0,3) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Ammonia concentration/content Spectrophotometric method Range Range PN-Z-71-Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(1,2 - 60) mg/m3"},{"name":"范围","range":"(0,006 - 0,3) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 氨浓度/含量 分光光度法 范围 范围 PN-Z-71-Z-04041","technique_zh":"分光光度法","methodology_zh":"氨浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4723","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,5 - 28) mg/m3"},{"name":"Zakres","range":"(0,010 - 0,160) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,5 - 28) mg/m3\nZakres (0,010 - 0,160) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,5 - 28) mg/m3\nZakres (0,010 - 0,160) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,5 - 28) mg/m3\nZakres (0,010 - 0,160) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,5 - 28) mg/m3"},{"name":"Range","range":"(0,010 - 0,160) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Hydrogen sulphide concentration/content Spectrophotometric method Range Range PN-Z-04015-13:1996","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,5 - 28) mg/m3"},{"name":"范围","range":"(0,010 - 0,160) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 硫化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","methodology_zh":"硫化氢的浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4724","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,29 - 23) mg/m3"},{"name":"Zakres","range":"(0,23 – 18,4) ppm"},{"name":"Zakres","range":"(0,0013 - 0,052) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,29 - 23) mg/m3\nZakres (0,23 – 18,4) ppm\nZakres (0,0013 - 0,052) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-04009-11:2008","norm_bases":["PN-04009-11:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,29 - 23) mg/m3\nZakres (0,23 – 18,4) ppm\nZakres (0,0013 - 0,052) mg w próbce\nMetoda spektrofotometryczna PN-04009-11:2008 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc tlenku azotu\nZakres:\nZakres (0,29 - 23) mg/m3\nZakres (0,23 – 18,4) ppm\nZakres (0,0013 - 0,052) mg w probce\nMetoda spektrofotometryczna PN-04009-11:2008","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen monoxide concentration/content","parameters_en":[{"name":"Range","range":"(0,29 - 23) mg/m3"},{"name":"Range","range":"(0,23 – 18,4) ppm"},{"name":"Range","range":"(0,0013 - 0,052) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Nitrogen monoxide concentration/content Spectrophotometric method Range Range Range PN-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,29 - 23) mg/m3"},{"name":"范围","range":"(0,23 – 18,4) ppm"},{"name":"范围","range":"(0,0013 - 0,052) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 一氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-04009-11:2008","technique_zh":"分光光度法","methodology_zh":"一氧化氮的浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4725","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,089 – 7,1) mg/m3"},{"name":"Zakres","range":"(0,05 – 3,7) ppm"},{"name":"Zakres","range":"(0,00040 - 0,016) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,089 – 7,1) mg/m3\nZakres (0,05 – 3,7) ppm\nZakres (0,00040 - 0,016) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-04009-11:2008","norm_bases":["PN-04009-11:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,089 – 7,1) mg/m3\nZakres (0,05 – 3,7) ppm\nZakres (0,00040 - 0,016) mg w próbce\nMetoda spektrofotometryczna PN-04009-11:2008 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc ditlenku azotu\nZakres:\nZakres (0,089 – 7,1) mg/m3\nZakres (0,05 – 3,7) ppm\nZakres (0,00040 - 0,016) mg w probce\nMetoda spektrofotometryczna PN-04009-11:2008","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,089 – 7,1) mg/m3"},{"name":"Range","range":"(0,05 – 3,7) ppm"},{"name":"Range","range":"(0,00040 - 0,016) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Nitrogen dioxide concentration/content Spectrophotometric method Range Range Range PN-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,089 – 7,1) mg/m3"},{"name":"范围","range":"(0,05 – 3,7) ppm"},{"name":"范围","range":"(0,00040 - 0,016) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 二氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-04009-11:2008","technique_zh":"分光光度法","methodology_zh":"二氧化氮的浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4726","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość kwasu azotowego","parameters":[{"name":"Zakres","range":"(0,120 – 9,7) mg/m3"},{"name":"Zakres","range":"(0,00055 - 0,022) mg w próbce"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie/zawartość kwasu azotowego\nZakres:\nZakres (0,120 – 9,7) mg/m3\nZakres (0,00055 - 0,022) mg w próbce\n(z obliczeń)","reference":"PN-04009-11:2008","norm_bases":["PN-04009-11:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość kwasu azotowego\nZakres:\nZakres (0,120 – 9,7) mg/m3\nZakres (0,00055 - 0,022) mg w próbce\n(z obliczeń) PN-04009-11:2008 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc kwasu azotowego\nZakres:\nZakres (0,120 – 9,7) mg/m3\nZakres (0,00055 - 0,022) mg w probce\n(z obliczen) PN-04009-11:2008","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,120 – 9,7) mg/m3"},{"name":"Range","range":"(0,00055 - 0,022) mg w próbce"},{"name":"(calculated)"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Range Range (calculated) PN-04009-11:2008","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,120 – 9,7) mg/m3"},{"name":"范围","range":"(0,00055 - 0,022) mg w próbce"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 范围 范围 （计算得出） PN-04009-11:2008","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4727","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,065 – 5,0) mg/m3"},{"name":"Zakres","range":"(0,00026 - 0,0050) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,065 – 5,0) mg/m3\nZakres (0,00026 - 0,0050) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość chloru\nZakres:\nZakres (0,065 – 5,0) mg/m3\nZakres (0,00026 - 0,0050) mg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc chloru\nZakres:\nZakres (0,065 – 5,0) mg/m3\nZakres (0,00026 - 0,0050) mg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,065 – 5,0) mg/m3"},{"name":"Range","range":"(0,00026 - 0,0050) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Chlorine concentration/content Spectrophotometric method Range Range PN-75/Z-04037/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,065 – 5,0) mg/m3"},{"name":"范围","range":"(0,00026 - 0,0050) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 氯的浓度/含量 分光光度法 范围 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","methodology_zh":"氯的浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4728","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,13 – 6,6) mg/m3"},{"name":"Zakres","range":"(0,0010 - 0,040) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,13 – 6,6) mg/m3\nZakres (0,0010 - 0,040) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045/02","norm_bases":["PN-76/Z-04045/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,13 – 6,6) mg/m3\nZakres (0,0010 - 0,040) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045/02 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,13 – 6,6) mg/m3\nZakres (0,0010 - 0,040) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045/02","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,13 – 6,6) mg/m3"},{"name":"Range","range":"(0,0010 - 0,040) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Formaldehyde concentration/content Spectrophotometric method Range Range PN-76/Z-04045/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,13 – 6,6) mg/m3"},{"name":"范围","range":"(0,0010 - 0,040) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 甲醛浓度/含量 分光光度法 范围 范围 PN-76/Z-04045/02","technique_zh":"分光光度法","methodology_zh":"甲醛浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4729","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0150 – 0,450) mg/m3"},{"name":"Zakres","range":"(0,0010 - 0,0180) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 - 0,0180) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 - 0,0180) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 - 0,0180) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,0150 – 0,450) mg/m3"},{"name":"Range","range":"(0,0010 - 0,0180) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Ozone concentration/content Spectrophotometric method Range Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,0150 – 0,450) mg/m3"},{"name":"范围","range":"(0,0010 - 0,0180) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 臭氧的浓度/含量 分光光度法 范围 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","methodology_zh":"臭氧的浓度/含量","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c472a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość dekatlenku tetrafosforu","parameters":[{"name":"Zakres","range":"(0,050 – 5,0) mg/m3"},{"name":"Zakres","range":"(0,0010 - 0,10) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,050 – 5,0) mg/m3\nZakres (0,0010 - 0,10) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,050 – 5,0) mg/m3\nZakres (0,0010 - 0,10) mg w próbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc dekatlenku tetrafosforu\nZakres:\nZakres (0,050 – 5,0) mg/m3\nZakres (0,0010 - 0,10) mg w probce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tetraphosphorus decaoxide","parameters_en":[{"name":"Range","range":"(0,050 – 5,0) mg/m3"},{"name":"Range","range":"(0,0010 - 0,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Concentration/content of tetraphosphorus decaoxide Spectrophotometric method Range Range PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,050 – 5,0) mg/m3"},{"name":"范围","range":"(0,0010 - 0,10) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 分光光度法 范围 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c472b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość kwasu fosforowego","parameters":[{"name":"Zakres","range":"(0,0690 – 6,9) mg/m3"},{"name":"Zakres","range":"(0,00140 - 0,130) mg w próbce"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie/zawartość kwasu fosforowego\nZakres:\nZakres (0,0690 – 6,9) mg/m3\nZakres (0,00140 - 0,130) mg w próbce\n(z obliczeń)","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość kwasu fosforowego\nZakres:\nZakres (0,0690 – 6,9) mg/m3\nZakres (0,00140 - 0,130) mg w próbce\n(z obliczeń) PN-Z-04073-1:2014-08 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc kwasu fosforowego\nZakres:\nZakres (0,0690 – 6,9) mg/m3\nZakres (0,00140 - 0,130) mg w probce\n(z obliczen) PN-Z-04073-1:2014-08","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0690 – 6,9) mg/m3"},{"name":"Range","range":"(0,00140 - 0,130) mg w próbce"},{"name":"(calculated)"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Range Range (calculated) PN-Z-04073-1:2014-08","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,0690 – 6,9) mg/m3"},{"name":"范围","range":"(0,00140 - 0,130) mg w próbce"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 范围 范围 （计算得出） PN-Z-04073-1:2014-08","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c472c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość acetonu","parameters":[{"name":"Zakres","range":"(0,10 – 2000) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetonu\nZakres:\nZakres (0,10 – 2000) mg/m3\nZakres (0,0010 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-79-Z-04057.01","norm_bases":["PN-79-Z-04057.01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość acetonu\nZakres:\nZakres (0,10 – 2000) mg/m3\nZakres (0,0010 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-79-Z-04057.01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc acetonu\nZakres:\nZakres (0,10 – 2000) mg/m3\nZakres (0,0010 – 2,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-79-Z-04057.01","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetone concentration/content","parameters_en":[{"name":"Range","range":"(0,10 – 2000) mg/m3"},{"name":"Range","range":"(0,0010 – 2,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Acetone concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-79-Z-04057.01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10 – 2000) mg/m3"},{"name":"范围","range":"(0,0010 – 2,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 丙酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-79-Z-04057.01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"丙酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c472d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość ksylenu – mieszanina izomerów 1,2; 1,3; 1,4","parameters":[{"name":"m-ksylen"},{"name":"Zakres","range":"(0,0670-600) mg/m3"},{"name":"Zakres","range":"(0,0010 – 3,0) mg w próbce"},{"name":"o-ksylen"},{"name":"Zakres","range":"(0,0670-620) mg/m3"},{"name":"Zakres","range":"(0,0010 – 3,10) mg w próbce"},{"name":"p-ksylen"},{"name":"Zakres","range":"(0,0670-600) mg/m3"},{"name":"Zakres","range":"(0,0010 – 3,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość ksylenu – mieszanina izomerów 1,2; 1,3; 1,4\nZakres:\nm-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,0) mg w próbce\no-ksylen\nZakres (0,0670-620) mg/m3\nZakres (0,0010 – 3,10) mg w próbce\np-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78-Z-04116.01","norm_bases":["PN-78-Z-04116.01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość ksylenu – mieszanina izomerów 1,2; 1,3; 1,4\nZakres:\nm-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,0) mg w próbce\no-ksylen\nZakres (0,0670-620) mg/m3\nZakres (0,0010 – 3,10) mg w próbce\np-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78-Z-04116.01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc ksylenu – mieszanina izomerow 1,2; 1,3; 1,4\nZakres:\nm-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,0) mg w probce\no-ksylen\nZakres (0,0670-620) mg/m3\nZakres (0,0010 – 3,10) mg w probce\np-ksylen\nZakres (0,0670-600) mg/m3\nZakres (0,0010 – 3,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78-Z-04116.01","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"m-xylene"},{"name":"Range","range":"(0,0670-600) mg/m3"},{"name":"Range","range":"(0,0010 – 3,0) mg w próbce"},{"name":"o-xylene"},{"name":"Range","range":"(0,0670-620) mg/m3"},{"name":"Range","range":"(0,0010 – 3,10) mg w próbce"},{"name":"p-xylene"},{"name":"Range","range":"(0,0670-600) mg/m3"},{"name":"Range","range":"(0,0010 – 3,00) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) m-xylene Range Range o-xylene Range Range p-xylene Range Range PN-78-Z-04116.01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"间二甲苯"},{"name":"范围","range":"(0,0670-600) mg/m3"},{"name":"范围","range":"(0,0010 – 3,0) mg w próbce"},{"name":"邻二甲苯"},{"name":"范围","range":"(0,0670-620) mg/m3"},{"name":"范围","range":"(0,0010 – 3,10) mg w próbce"},{"name":"p-ksylen"},{"name":"范围","range":"(0,0670-600) mg/m3"},{"name":"范围","range":"(0,0010 – 3,00) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 间二甲苯 范围 范围 邻二甲苯 范围 范围 范围 范围 PN-78-Z-04116.01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c472e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Suma zawartości ksylenu – mieszanina izomerów 1,2; 1,3; 1,4 (z obliczeń)","parameters":[{"name":"Zakres","range":"(0,0670-1820) mg/m3"},{"name":"Zakres","range":"(0,0010 – 9,10) mg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Suma zawartości ksylenu – mieszanina izomerów 1,2; 1,3; 1,4 (z obliczeń)\nZakres:\nZakres (0,0670-1820) mg/m3\nZakres (0,0010 – 9,10) mg w próbce","reference":"PN-78-Z-04116.01","norm_bases":["PN-78-Z-04116.01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Suma zawartości ksylenu – mieszanina izomerów 1,2; 1,3; 1,4 (z obliczeń)\nZakres:\nZakres (0,0670-1820) mg/m3\nZakres (0,0010 – 9,10) mg w próbce PN-78-Z-04116.01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Suma zawartosci ksylenu – mieszanina izomerow 1,2; 1,3; 1,4 (z obliczen)\nZakres:\nZakres (0,0670-1820) mg/m3\nZakres (0,0010 – 9,10) mg w probce PN-78-Z-04116.01","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0670-1820) mg/m3"},{"name":"Range","range":"(0,0010 – 9,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Range Range PN-78-Z-04116.01","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-1820) mg/m3"},{"name":"范围","range":"(0,0010 – 9,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 范围 范围 PN-78-Z-04116.01","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c472f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość etanolu","parameters":[{"name":"Zakres","range":"(0,050–4537) mg/m3"},{"name":"Zakres","range":"(0,0010 – 16,3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etanolu\nZakres:\nZakres (0,050–4537) mg/m3\nZakres (0,0010 – 16,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EV-PB-4 wydanie 1 z dnia 02.01.2017 r.","norm_bases":["EV-PB-4 wydanie 1 z dnia 02.01.2017 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość etanolu\nZakres:\nZakres (0,050–4537) mg/m3\nZakres (0,0010 – 16,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EV-PB-4 wydanie 1 z dnia 02.01.2017 r. Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc etanolu\nZakres:\nZakres (0,050–4537) mg/m3\nZakres (0,0010 – 16,3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EV-PB-4 wydanie 1 z dnia 02.01.2017 r.","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethanol concentration/content","parameters_en":[{"name":"Range","range":"(0,050–4537) mg/m3"},{"name":"Range","range":"(0,0010 – 16,3) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Ethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range EV-PB-4 wydanie 1 z dnia 02.01.2017 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050–4537) mg/m3"},{"name":"范围","range":"(0,0010 – 16,3) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 EV-PB-4 wydanie 1 z dnia 02.01.2017 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4730","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość butan-1-olu","parameters":[{"name":"Zakres","range":"(0,050 – 569) mg/m3"},{"name":"Zakres","range":"(0,0010 – 4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-1-olu\nZakres:\nZakres (0,050 – 569) mg/m3\nZakres (0,0010 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02","norm_bases":["PN-89/Z-04023/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość butan-1-olu\nZakres:\nZakres (0,050 – 569) mg/m3\nZakres (0,0010 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc butan-1-olu\nZakres:\nZakres (0,050 – 569) mg/m3\nZakres (0,0010 – 4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Butan-1-ol concentration/content","parameters_en":[{"name":"Range","range":"(0,050 – 569) mg/m3"},{"name":"Range","range":"(0,0010 – 4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Butan-1-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050 – 569) mg/m3"},{"name":"范围","range":"(0,0010 – 4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 正丁醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"正丁醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4731","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-metylopropanu-1-olu","parameters":[{"name":"Zakres","range":"(0,139 – 1708) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-metylopropanu-1-olu\nZakres:\nZakres (0,139 – 1708) mg/m3\nZakres (0,001 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86-Z-04155/02","norm_bases":["PN-86-Z-04155/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-metylopropanu-1-olu\nZakres:\nZakres (0,139 – 1708) mg/m3\nZakres (0,001 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86-Z-04155/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-metylopropanu-1-olu\nZakres:\nZakres (0,139 – 1708) mg/m3\nZakres (0,001 – 4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86-Z-04155/02","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,139 – 1708) mg/m3"},{"name":"Range","range":"(0,001 – 4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86-Z-04155/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,139 – 1708) mg/m3"},{"name":"范围","range":"(0,001 – 4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86-Z-04155/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4732","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(0,0670-2441) mg/m3"},{"name":"Zakres","range":"(0,02 – 667) ppm"},{"name":"Zakres","range":"(0,0010-12,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu etylu\nZakres:\nZakres (0,0670-2441) mg/m3\nZakres (0,02 – 667) ppm\nZakres (0,0010-12,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78-Z-04119/01","norm_bases":["PN-78-Z-04119/01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu etylu\nZakres:\nZakres (0,0670-2441) mg/m3\nZakres (0,02 – 667) ppm\nZakres (0,0010-12,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78-Z-04119/01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu etylu\nZakres:\nZakres (0,0670-2441) mg/m3\nZakres (0,02 – 667) ppm\nZakres (0,0010-12,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78-Z-04119/01","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,0670-2441) mg/m3"},{"name":"Range","range":"(0,02 – 667) ppm"},{"name":"Range","range":"(0,0010-12,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Ethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-78-Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-2441) mg/m3"},{"name":"范围","range":"(0,02 – 667) ppm"},{"name":"范围","range":"(0,0010-12,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙酸乙酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-78-Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙酸乙酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4733","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu n-butylu","parameters":[{"name":"Zakres","range":"(0,0670-1138) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu n-butylu\nZakres:\nZakres (0,0670-1138) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78-Z-04119/01","norm_bases":["PN-78-Z-04119/01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu n-butylu\nZakres:\nZakres (0,0670-1138) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78-Z-04119/01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu n-butylu\nZakres:\nZakres (0,0670-1138) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78-Z-04119/01","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of n-butyl acetate","parameters_en":[{"name":"Range","range":"(0,0670-1138) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of n-butyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-78-Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-1138) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-78-Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4734","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość toluenu","parameters":[{"name":"Zakres","range":"(0,050-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość toluenu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość toluenu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc toluenu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, nr 1(67), s.35 - 44","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Toluene concentration/content","parameters_en":[{"name":"Range","range":"(0,050-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Toluene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 甲苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"甲苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4735","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-butoksyetanolu","parameters":[{"name":"Zakres","range":"(0,050-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r. | PN-Z-04023-02:1998","norm_bases":["EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r.","PN-Z-04023-02:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r. | PN-Z-04023-02:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-butoksyetanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r. | PN-Z-04023-02:1998","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-butoxyethanol concentration/content","parameters_en":[{"name":"Range","range":"(0,050-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent 2-butoxyethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r. | PN-Z-04023-02:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 2-丁氧基乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 EV-PB-4 wydanie nr 1 z dnia 02.01.2017 r. | PN-Z-04023-02:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"2-丁氧基乙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4736","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,050-333) mg/m3"},{"name":"Zakres","range":"(0,015 – 102,7) ppm"},{"name":"Zakres","range":"(0,0010-2,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzenu\nZakres:\nZakres (0,050-333) mg/m3\nZakres (0,015 – 102,7) ppm\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość benzenu\nZakres:\nZakres (0,050-333) mg/m3\nZakres (0,015 – 102,7) ppm\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc benzenu\nZakres:\nZakres (0,050-333) mg/m3\nZakres (0,015 – 102,7) ppm\nZakres (0,0010-2,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration/content","parameters_en":[{"name":"Range","range":"(0,050-333) mg/m3"},{"name":"Range","range":"(0,015 – 102,7) ppm"},{"name":"Range","range":"(0,0010-2,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Benzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-333) mg/m3"},{"name":"范围","range":"(0,015 – 102,7) ppm"},{"name":"范围","range":"(0,0010-2,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4737","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(24,0 - 2083) mg/m3"},{"name":"Zakres","range":"(0,48 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (24,0 - 2083) mg/m3\nZakres (0,48 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2 15 August 1994","norm_bases":["PN-81-Z-04134.02","NIOSH Method 1550, Issue 2 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (24,0 - 2083) mg/m3\nZakres (0,48 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (24,0 - 2083) mg/m3\nZakres (0,48 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2 15 August 1994","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extraction naphtha concentration/content","parameters_en":[{"name":"Range","range":"(24,0 - 2083) mg/m3"},{"name":"Range","range":"(0,48 - 15) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Extraction naphtha concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(24,0 - 2083) mg/m3"},{"name":"范围","range":"(0,48 - 15) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 抽提汽油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"抽提汽油的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4738","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(16 – 1388) mg/m3"},{"name":"Zakres","range":"(0,32 - 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (16 – 1388) mg/m3\nZakres (0,32 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2 15 August 1994","norm_bases":["PN-81-Z-04134.03","NIOSH Method 1550, Issue 2 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (16 – 1388) mg/m3\nZakres (0,32 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc benzyny do lakierow\nZakres:\nZakres (16 – 1388) mg/m3\nZakres (0,32 - 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2 15 August 1994","categories":["environment","automotive"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"White spirit concentration/content","parameters_en":[{"name":"Range","range":"(16 – 1388) mg/m3"},{"name":"Range","range":"(0,32 - 10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent White spirit concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(16 – 1388) mg/m3"},{"name":"范围","range":"(0,32 - 10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 油漆用溶剂汽油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"油漆用溶剂汽油的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4739","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość styrenu","parameters":[{"name":"Zakres","range":"(0,010-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość styrenu\nZakres:\nZakres (0,010-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86-Z-04152/02","norm_bases":["PN-86-Z-04152/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość styrenu\nZakres:\nZakres (0,010-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86-Z-04152/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc styrenu\nZakres:\nZakres (0,010-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86-Z-04152/02","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene concentration/content","parameters_en":[{"name":"Range","range":"(0,010-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Styrene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86-Z-04152/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,010-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86-Z-04152/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość metakrylanu metylu","parameters":[{"name":"Zakres","range":"(0,10-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-92-Z-04113/09","norm_bases":["PN-92-Z-04113/09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-92-Z-04113/09 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc metakrylanu metylu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-92-Z-04113/09","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl methacrylate concentration/content","parameters_en":[{"name":"Range","range":"(0,10-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Methyl methacrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-92-Z-04113/09","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 甲基丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-92-Z-04113/09","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"甲基丙烯酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(0,050-1128) mg/m3"},{"name":"Zakres","range":"(0,0010-8,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,050-1128) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,050-1128) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc etylobenzenu\nZakres:\nZakres (0,050-1128) mg/m3\nZakres (0,0010-8,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, nr 1(67), s.35 - 44","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylbenzene concentration/content","parameters_en":[{"name":"Range","range":"(0,050-1128) mg/m3"},{"name":"Range","range":"(0,0010-8,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Ethylbenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-1128) mg/m3"},{"name":"范围","range":"(0,0010-8,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość heksanu","parameters":[{"name":"Zakres","range":"(0,10-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość heksanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-3:2003","norm_bases":["PN-Z-04136-3:2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość heksanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-3:2003 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc heksanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-3:2003","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexane concentration/content","parameters_en":[{"name":"Range","range":"(0,10-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Hexane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04136-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 正己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04136-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"正己烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość cykloheksanonu","parameters":[{"name":"Zakres","range":"(0,10-333) mg/m3"},{"name":"Zakres","range":"(0,0010-2,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04447:2014-06","norm_bases":["PN-Z-04447:2014-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04447:2014-06 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc cykloheksanonu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04447:2014-06","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyclohexanone concentration/content","parameters_en":[{"name":"Range","range":"(0,10-333) mg/m3"},{"name":"Range","range":"(0,0010-2,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Cyclohexanone concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04447:2014-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-333) mg/m3"},{"name":"范围","range":"(0,0010-2,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 环己酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04447:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"环己酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(0,050-1124) mg/m3"},{"name":"Zakres","range":"(0,0010-8,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanu\nZakres:\nZakres (0,050-1124) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość cykloheksanu\nZakres:\nZakres (0,050-1124) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc cykloheksanu\nZakres:\nZakres (0,050-1124) mg/m3\nZakres (0,0010-8,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, nr 1(67), s.35 - 44","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyclohexane concentration/content","parameters_en":[{"name":"Range","range":"(0,050-1124) mg/m3"},{"name":"Range","range":"(0,0010-8,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Cyclohexane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-1124) mg/m3"},{"name":"范围","range":"(0,0010-8,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 环己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1(67), s.35 - 44","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"环己烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c473f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość heptanu","parameters":[{"name":"Zakres","range":"(0,139-6776) mg/m3"},{"name":"Zakres","range":"(0,0010-16,30) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość heptanu\nZakres:\nZakres (0,139-6776) mg/m3\nZakres (0,0010-16,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2004 nr. 4(42) s. 67-73","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2004 nr. 4(42) s. 67-73"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość heptanu\nZakres:\nZakres (0,139-6776) mg/m3\nZakres (0,0010-16,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2004 nr. 4(42) s. 67-73 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc heptanu\nZakres:\nZakres (0,139-6776) mg/m3\nZakres (0,0010-16,30) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2004 nr. 4(42) s. 67-73","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Heptane concentration/content","parameters_en":[{"name":"Range","range":"(0,139-6776) mg/m3"},{"name":"Range","range":"(0,0010-16,30) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Heptane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2004 nr. 4(42) s. 67-73","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,139-6776) mg/m3"},{"name":"范围","range":"(0,0010-16,30) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 正庚烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2004 nr. 4(42) s. 67-73","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"正庚烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4740","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(0,10-333) mg/m3"},{"name":"Zakres","range":"(0,0010-2,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu winylu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-87-Z-04178/02","norm_bases":["PN-87-Z-04178/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu winylu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-87-Z-04178/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu winylu\nZakres:\nZakres (0,10-333) mg/m3\nZakres (0,0010-2,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-87-Z-04178/02","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,10-333) mg/m3"},{"name":"Range","range":"(0,0010-2,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Vinyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-87-Z-04178/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-333) mg/m3"},{"name":"范围","range":"(0,0010-2,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙酸乙烯酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-87-Z-04178/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙酸乙烯酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4741","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość akrylonitrylu","parameters":[{"name":"Zakres","range":"(0,050-500) mg/m3"},{"name":"Zakres","range":"(0,02 – 227) ppm"},{"name":"Zakres","range":"(0,0010-3,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,050-500) mg/m3\nZakres (0,02 – 227) ppm\nZakres (0,0010-3,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-12:2005","norm_bases":["PN-Z-04113-12:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,050-500) mg/m3\nZakres (0,02 – 227) ppm\nZakres (0,0010-3,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-12:2005 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc akrylonitrylu\nZakres:\nZakres (0,050-500) mg/m3\nZakres (0,02 – 227) ppm\nZakres (0,0010-3,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-12:2005","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylonitrile concentration/content","parameters_en":[{"name":"Range","range":"(0,050-500) mg/m3"},{"name":"Range","range":"(0,02 – 227) ppm"},{"name":"Range","range":"(0,0010-3,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Acrylonitrile concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04113-12:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-500) mg/m3"},{"name":"范围","range":"(0,02 – 227) ppm"},{"name":"范围","range":"(0,0010-3,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 丙烯腈的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04113-12:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"丙烯腈的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4742","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość dichlorometanu","parameters":[{"name":"Zakres","range":"(0,10-569) mg/m3"},{"name":"Zakres","range":"(0,03 – 161) ppm"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość dichlorometanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,03 – 161) ppm\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-83-Z-04110/02","norm_bases":["PN-83-Z-04110/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość dichlorometanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,03 – 161) ppm\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-83-Z-04110/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc dichlorometanu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,03 – 161) ppm\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-83-Z-04110/02","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dichloromethane concentration/content","parameters_en":[{"name":"Range","range":"(0,10-569) mg/m3"},{"name":"Range","range":"(0,03 – 161) ppm"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Dichloromethane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-83-Z-04110/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-569) mg/m3"},{"name":"范围","range":"(0,03 – 161) ppm"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 二氯甲烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-83-Z-04110/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"二氯甲烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4743","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość trimetylobenzenu – mieszanina izomerów:","parameters":[{"name":"1,2,3 trimetylobenzen"},{"name":"Zakres","range":"(0,070-600) mg/m3"},{"name":"Zakres","range":"(0,0010-3,0) mg w próbce"},{"name":"1,2,4 trimetylobenzen"},{"name":"Zakres","range":"(0,0670-620) mg/m3"},{"name":"Zakres","range":"(0,0010-3,10) mg w próbce"},{"name":"1,3,5 trimetylobenzen"},{"name":"Zakres","range":"(0,0670-600) mg/m3"},{"name":"Zakres","range":"(0,0010-3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość trimetylobenzenu – mieszanina izomerów:\nZakres:\n1,2,3 trimetylobenzen\nZakres (0,070-600) mg/m3\nZakres (0,0010-3,0) mg w próbce\n1,2,4 trimetylobenzen\nZakres (0,0670-620) mg/m3\nZakres (0,0010-3,10) mg w próbce\n1,3,5 trimetylobenzen\nZakres (0,0670-600) mg/m3\nZakres (0,0010-3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998","norm_bases":["PN-Z-04016-4:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość trimetylobenzenu – mieszanina izomerów:\nZakres:\n1,2,3 trimetylobenzen\nZakres (0,070-600) mg/m3\nZakres (0,0010-3,0) mg w próbce\n1,2,4 trimetylobenzen\nZakres (0,0670-620) mg/m3\nZakres (0,0010-3,10) mg w próbce\n1,3,5 trimetylobenzen\nZakres (0,0670-600) mg/m3\nZakres (0,0010-3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-4:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc trimetylobenzenu – mieszanina izomerow:\nZakres:\n1,2,3 trimetylobenzen\nZakres (0,070-600) mg/m3\nZakres (0,0010-3,0) mg w probce\n1,2,4 trimetylobenzen\nZakres (0,0670-620) mg/m3\nZakres (0,0010-3,10) mg w probce\n1,3,5 trimetylobenzen\nZakres (0,0670-600) mg/m3\nZakres (0,0010-3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-4:1998","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"1,2,3 trimetylobenzen"},{"name":"Range","range":"(0,070-600) mg/m3"},{"name":"Range","range":"(0,0010-3,0) mg w próbce"},{"name":"1,2,4 trimetylobenzen"},{"name":"Range","range":"(0,0670-620) mg/m3"},{"name":"Range","range":"(0,0010-3,10) mg w próbce"},{"name":"1,3,5 trimetylobenzen"},{"name":"Range","range":"(0,0670-600) mg/m3"},{"name":"Range","range":"(0,0010-3,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Range Range Range Range PN-Z-04016-4:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"1,2,3 trimetylobenzen"},{"name":"范围","range":"(0,070-600) mg/m3"},{"name":"范围","range":"(0,0010-3,0) mg w próbce"},{"name":"1,2,4 trimetylobenzen"},{"name":"范围","range":"(0,0670-620) mg/m3"},{"name":"范围","range":"(0,0010-3,10) mg w próbce"},{"name":"1,3,5 trimetylobenzen"},{"name":"范围","range":"(0,0670-600) mg/m3"},{"name":"范围","range":"(0,0010-3,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 范围 范围 PN-Z-04016-4:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4744","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Suma stężeń/zawartości trimetylobenzenu – mieszanina izomerów (1,2,3; 1,2,4; 1,3,5) (z obliczeń)","parameters":[{"name":"Zakres","range":"(0,070 – 1820) mg/m3"},{"name":"Zakres","range":"(0,0010 – 9,10) mg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężeń/zawartości trimetylobenzenu – mieszanina izomerów (1,2,3; 1,2,4; 1,3,5) (z obliczeń)\nZakres:\nZakres (0,070 – 1820) mg/m3\nZakres (0,0010 – 9,10) mg w próbce","reference":"PN-Z-04016-4:1998","norm_bases":["PN-Z-04016-4:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Suma stężeń/zawartości trimetylobenzenu – mieszanina izomerów (1,2,3; 1,2,4; 1,3,5) (z obliczeń)\nZakres:\nZakres (0,070 – 1820) mg/m3\nZakres (0,0010 – 9,10) mg w próbce PN-Z-04016-4:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Suma stezen/zawartosci trimetylobenzenu – mieszanina izomerow (1,2,3; 1,2,4; 1,3,5) (z obliczen)\nZakres:\nZakres (0,070 – 1820) mg/m3\nZakres (0,0010 – 9,10) mg w probce PN-Z-04016-4:1998","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,070 – 1820) mg/m3"},{"name":"Range","range":"(0,0010 – 9,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Range Range PN-Z-04016-4:1998","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,070 – 1820) mg/m3"},{"name":"范围","range":"(0,0010 – 9,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 范围 范围 PN-Z-04016-4:1998","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4745","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość tetrahydrofuranu","parameters":[{"name":"Zakres","range":"(0,0670-820) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (0,0670-820) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2015 nr. 4(86), s. 191-202","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2015 nr. 4(86), s. 191-202"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (0,0670-820) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2015 nr. 4(86), s. 191-202 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc tetrahydrofuranu\nZakres:\nZakres (0,0670-820) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2015 nr. 4(86), s. 191-202","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tetrahydrofuran","parameters_en":[{"name":"Range","range":"(0,0670-820) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of tetrahydrofuran Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2015 nr. 4(86), s. 191-202","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-820) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2015 nr. 4(86), s. 191-202","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4746","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość butan-2-olu","parameters":[{"name":"Zakres","range":"(0,0670-1627) mg/m3"},{"name":"Zakres","range":"(0,0010-8,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-2-olu\nZakres:\nZakres (0,0670-1627) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04155-4:1996","norm_bases":["PN-Z-04155-4:1996"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość butan-2-olu\nZakres:\nZakres (0,0670-1627) mg/m3\nZakres (0,0010-8,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04155-4:1996 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc butan-2-olu\nZakres:\nZakres (0,0670-1627) mg/m3\nZakres (0,0010-8,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04155-4:1996","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butan-2-ol","parameters_en":[{"name":"Range","range":"(0,0670-1627) mg/m3"},{"name":"Range","range":"(0,0010-8,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of butan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04155-4:1996","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-1627) mg/m3"},{"name":"范围","range":"(0,0010-8,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04155-4:1996","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4747","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość propan-2-olu","parameters":[{"name":"Zakres","range":"(0,20-7551) mg/m3"},{"name":"Zakres","range":"(0,0010-27,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-2-olu\nZakres:\nZakres (0,20-7551) mg/m3\nZakres (0,0010-27,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-92-Z-04224/02","norm_bases":["PN-92-Z-04224/02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość propan-2-olu\nZakres:\nZakres (0,20-7551) mg/m3\nZakres (0,0010-27,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-92-Z-04224/02 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc propan-2-olu\nZakres:\nZakres (0,20-7551) mg/m3\nZakres (0,0010-27,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-92-Z-04224/02","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Propan-2-ol concentration/content","parameters_en":[{"name":"Range","range":"(0,20-7551) mg/m3"},{"name":"Range","range":"(0,0010-27,2) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Propan-2-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-92-Z-04224/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,20-7551) mg/m3"},{"name":"范围","range":"(0,0010-27,2) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 异丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-92-Z-04224/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"异丙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4748","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(0,10-569) mg/m3"},{"name":"Zakres","range":"(0,015 – 83) ppm"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,015 – 83) ppm\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78-Z-04118-01","norm_bases":["PN-78-Z-04118-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,015 – 83) ppm\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78-Z-04118-01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc tetrachloroetenu\nZakres:\nZakres (0,10-569) mg/m3\nZakres (0,015 – 83) ppm\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78-Z-04118-01","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrachloroethene concentration/content","parameters_en":[{"name":"Range","range":"(0,10-569) mg/m3"},{"name":"Range","range":"(0,015 – 83) ppm"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Tetrachloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-78-Z-04118-01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10-569) mg/m3"},{"name":"范围","range":"(0,015 – 83) ppm"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 四氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-78-Z-04118-01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"四氯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4749","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,175 – 600) mg/m3"},{"name":"Zakres","range":"(0,08 – 267) ppm"},{"name":"Zakres","range":"(0,00118 – 0,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,175 – 600) mg/m3\nZakres (0,08 – 267) ppm\nZakres (0,00118 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-84-Z-04014/02 Podstawy i Metody Oceny Środowiska Pracy 2017 nr 1(95), s. 73-85","norm_bases":["PN-84-Z-04014/02 Podstawy i Metody Oceny Środowiska Pracy 2017 nr 1(95), s. 73-85"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,175 – 600) mg/m3\nZakres (0,08 – 267) ppm\nZakres (0,00118 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-84-Z-04014/02 Podstawy i Metody Oceny Środowiska Pracy 2017 nr 1(95), s. 73-85 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,175 – 600) mg/m3\nZakres (0,08 – 267) ppm\nZakres (0,00118 – 0,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-84-Z-04014/02 Podstawy i Metody Oceny Srodowiska Pracy 2017 nr 1(95), s. 73-85","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of buta-1,3-diene","parameters_en":[{"name":"Range","range":"(0,175 – 600) mg/m3"},{"name":"Range","range":"(0,08 – 267) ppm"},{"name":"Range","range":"(0,00118 – 0,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of buta-1,3-diene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-84-Z-04014/02 Podstawy i Metody Oceny Środowiska Pracy 2017 nr 1(95), s. 73-85","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,175 – 600) mg/m3"},{"name":"范围","range":"(0,08 – 267) ppm"},{"name":"范围","range":"(0,00118 – 0,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-84-Z-04014/02 Podstawy i Metody Oceny Środowiska Pracy 2017 nr 1(95), s. 73-85","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c474a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość chloroetenu","parameters":[{"name":"Zakres","range":"(0,5 - 60) mg/m3"},{"name":"Zakres","range":"(0,19 – 23) ppm"},{"name":"Zakres","range":"(0,005 – 0,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,5 - 60) mg/m3\nZakres (0,19 – 23) ppm\nZakres (0,005 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78-Z-04112/01","norm_bases":["PN-78-Z-04112/01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,5 - 60) mg/m3\nZakres (0,19 – 23) ppm\nZakres (0,005 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78-Z-04112/01 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc chloroetenu\nZakres:\nZakres (0,5 - 60) mg/m3\nZakres (0,19 – 23) ppm\nZakres (0,005 – 0,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78-Z-04112/01","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroethene","parameters_en":[{"name":"Range","range":"(0,5 - 60) mg/m3"},{"name":"Range","range":"(0,19 – 23) ppm"},{"name":"Range","range":"(0,005 – 0,6) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of chloroethene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-78-Z-04112/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,5 - 60) mg/m3"},{"name":"范围","range":"(0,19 – 23) ppm"},{"name":"范围","range":"(0,005 – 0,6) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-78-Z-04112/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c474b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 1-metoksy-2-propanolu","parameters":[{"name":"Zakres","range":"(0,050-569) mg/m3"},{"name":"Zakres","range":"(0,0010-4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04354:2005","norm_bases":["PN-Z-04354:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04354:2005 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 1-metoksy-2-propanolu\nZakres:\nZakres (0,050-569) mg/m3\nZakres (0,0010-4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04354:2005","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,050-569) mg/m3"},{"name":"Range","range":"(0,0010-4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04354:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050-569) mg/m3"},{"name":"范围","range":"(0,0010-4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04354:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c474c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość butan-2-onu","parameters":[{"name":"Zakres","range":"(0,230-1250) mg/m3"},{"name":"Zakres","range":"(0,0010-3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-2-onu\nZakres:\nZakres (0,230-1250) mg/m3\nZakres (0,0010-3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04449:2014-06","norm_bases":["PN-Z-04449:2014-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość butan-2-onu\nZakres:\nZakres (0,230-1250) mg/m3\nZakres (0,0010-3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04449:2014-06 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc butan-2-onu\nZakres:\nZakres (0,230-1250) mg/m3\nZakres (0,0010-3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04449:2014-06","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butan-2-one","parameters_en":[{"name":"Range","range":"(0,230-1250) mg/m3"},{"name":"Range","range":"(0,0010-3,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of butan-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04449:2014-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,230-1250) mg/m3"},{"name":"范围","range":"(0,0010-3,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 丁酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04449:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"丁酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c474d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-etoksyetanolu","parameters":[{"name":"Zakres","range":"(0,0450 – 126) mg/m3"},{"name":"Zakres","range":"(0,01 – 33,7) ppm"},{"name":"Zakres","range":"(0,00090 – 0,91) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-etoksyetanolu\nZakres:\nZakres (0,0450 – 126) mg/m3\nZakres (0,01 – 33,7) ppm\nZakres (0,00090 – 0,91) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-etoksyetanolu\nZakres:\nZakres (0,0450 – 126) mg/m3\nZakres (0,01 – 33,7) ppm\nZakres (0,00090 – 0,91) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-etoksyetanolu\nZakres:\nZakres (0,0450 – 126) mg/m3\nZakres (0,01 – 33,7) ppm\nZakres (0,00090 – 0,91) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-ethoxyethanol","parameters_en":[{"name":"Range","range":"(0,0450 – 126) mg/m3"},{"name":"Range","range":"(0,01 – 33,7) ppm"},{"name":"Range","range":"(0,00090 – 0,91) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-ethoxyethanol Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04023-02:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0450 – 126) mg/m3"},{"name":"范围","range":"(0,01 – 33,7) ppm"},{"name":"范围","range":"(0,00090 – 0,91) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c474e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(0,050 – 600) mg/m3"},{"name":"Zakres","range":"(0,00070 – 3,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 4-metylopentan-2-onu\nZakres:\nZakres (0,050 – 600) mg/m3\nZakres (0,00070 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04372:2009","norm_bases":["PN-Z-04372:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 4-metylopentan-2-onu\nZakres:\nZakres (0,050 – 600) mg/m3\nZakres (0,00070 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04372:2009 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 4-metylopentan-2-onu\nZakres:\nZakres (0,050 – 600) mg/m3\nZakres (0,00070 – 3,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04372:2009","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"4-methylpentan-2-one concentration/content","parameters_en":[{"name":"Range","range":"(0,050 – 600) mg/m3"},{"name":"Range","range":"(0,00070 – 3,00) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent 4-methylpentan-2-one concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04372:2009","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050 – 600) mg/m3"},{"name":"范围","range":"(0,00070 – 3,00) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 4-甲基-2-戊酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04372:2009","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"4-甲基-2-戊酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c474f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość akrylanu metylu","parameters":[{"name":"Zakres","range":"(0,120 – 680) mg/m3"},{"name":"Zakres","range":"(0,00120 – 4,90) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,120 – 680) mg/m3\nZakres (0,00120 – 4,90) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-05:1989","norm_bases":["PN-Z-04113-05:1989"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,120 – 680) mg/m3\nZakres (0,00120 – 4,90) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-05:1989 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc akrylanu metylu\nZakres:\nZakres (0,120 – 680) mg/m3\nZakres (0,00120 – 4,90) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-05:1989","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acrylate concentration/content","parameters_en":[{"name":"Range","range":"(0,120 – 680) mg/m3"},{"name":"Range","range":"(0,00120 – 4,90) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Methyl acrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-05:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,120 – 680) mg/m3"},{"name":"范围","range":"(0,00120 – 4,90) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-05:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"丙烯酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4750","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość izopentanu (2-metylobutanu)","parameters":[{"name":"Zakres","range":"(0,240 – 6777) mg/m3"},{"name":"Zakres","range":"(0,00070 – 6,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość izopentanu (2-metylobutanu)\nZakres:\nZakres (0,240 – 6777) mg/m3\nZakres (0,00070 – 6,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04376:2010","norm_bases":["PN-Z-04376:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość izopentanu (2-metylobutanu)\nZakres:\nZakres (0,240 – 6777) mg/m3\nZakres (0,00070 – 6,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04376:2010 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc izopentanu (2-metylobutanu)\nZakres:\nZakres (0,240 – 6777) mg/m3\nZakres (0,00070 – 6,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04376:2010","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,240 – 6777) mg/m3"},{"name":"Range","range":"(0,00070 – 6,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04376:2010","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,240 – 6777) mg/m3"},{"name":"范围","range":"(0,00070 – 6,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04376:2010","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4751","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość metakrylanu butylu","parameters":[{"name":"Zakres","range":"(0,0740 – 920) mg/m3"},{"name":"Zakres","range":"(0,00110 – 4,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,0740 – 920) mg/m3\nZakres (0,00110 – 4,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04283:2001","norm_bases":["PN-Z-04283:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,0740 – 920) mg/m3\nZakres (0,00110 – 4,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04283:2001 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc metakrylanu butylu\nZakres:\nZakres (0,0740 – 920) mg/m3\nZakres (0,00110 – 4,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04283:2001","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butyl methacrylate","parameters_en":[{"name":"Range","range":"(0,0740 – 920) mg/m3"},{"name":"Range","range":"(0,00110 – 4,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of butyl methacrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04283:2001","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0740 – 920) mg/m3"},{"name":"范围","range":"(0,00110 – 4,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04283:2001","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4752","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość metylocykloheksanu","parameters":[{"name":"Zakres","range":"(0,0750 – 3375) mg/m3"},{"name":"Zakres","range":"(0,00150 – 24,3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metylocykloheksanu\nZakres:\nZakres (0,0750 – 3375) mg/m3\nZakres (0,00150 – 24,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011 nr. 1 (67), s. 185-192","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011 nr. 1 (67), s. 185-192"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość metylocykloheksanu\nZakres:\nZakres (0,0750 – 3375) mg/m3\nZakres (0,00150 – 24,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011 nr. 1 (67), s. 185-192 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc metylocykloheksanu\nZakres:\nZakres (0,0750 – 3375) mg/m3\nZakres (0,00150 – 24,3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011 nr. 1 (67), s. 185-192","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of methylcyclohexane","parameters_en":[{"name":"Range","range":"(0,0750 – 3375) mg/m3"},{"name":"Range","range":"(0,00150 – 24,3) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of methylcyclohexane Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2011 nr. 1 (67), s. 185-192","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0750 – 3375) mg/m3"},{"name":"范围","range":"(0,00150 – 24,3) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 甲基环己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2011 nr. 1 (67), s. 185-192","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"甲基环己烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4753","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu-2-butoksyetylu","parameters":[{"name":"Zakres","range":"(0,050 – 416) mg/m3"},{"name":"Zakres","range":"(0,000710 – 1,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-butoksyetylu\nZakres:\nZakres (0,050 – 416) mg/m3\nZakres (0,000710 – 1,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04304:2003","norm_bases":["PN-Z-04304:2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu-2-butoksyetylu\nZakres:\nZakres (0,050 – 416) mg/m3\nZakres (0,000710 – 1,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04304:2003 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu-2-butoksyetylu\nZakres:\nZakres (0,050 – 416) mg/m3\nZakres (0,000710 – 1,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04304:2003","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,050 – 416) mg/m3"},{"name":"Range","range":"(0,000710 – 1,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04304:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,050 – 416) mg/m3"},{"name":"范围","range":"(0,000710 – 1,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04304:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4754","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu-2-etoksyetylu","parameters":[{"name":"Zakres","range":"(0,110 – 470) mg/m3"},{"name":"Zakres","range":"(0,02 – 86) ppm"},{"name":"Zakres","range":"(0,00110 – 4,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-etoksyetylu\nZakres:\nZakres (0,110 – 470) mg/m3\nZakres (0,02 – 86) ppm\nZakres (0,00110 – 4,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu-2-etoksyetylu\nZakres:\nZakres (0,110 – 470) mg/m3\nZakres (0,02 – 86) ppm\nZakres (0,00110 – 4,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu-2-etoksyetylu\nZakres:\nZakres (0,110 – 470) mg/m3\nZakres (0,02 – 86) ppm\nZakres (0,00110 – 4,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,110 – 470) mg/m3"},{"name":"Range","range":"(0,02 – 86) ppm"},{"name":"Range","range":"(0,00110 – 4,70) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04023-02:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,110 – 470) mg/m3"},{"name":"范围","range":"(0,02 – 86) ppm"},{"name":"范围","range":"(0,00110 – 4,70) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4755","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu-2-metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(0,150 – 3291) mg/m3"},{"name":"Zakres","range":"(0,001450 – 23,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,150 – 3291) mg/m3\nZakres (0,001450 – 23,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-10:2008","norm_bases":["PN-Z-04119-10:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,150 – 3291) mg/m3\nZakres (0,001450 – 23,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-10:2008 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,150 – 3291) mg/m3\nZakres (0,001450 – 23,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-10:2008","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,150 – 3291) mg/m3"},{"name":"Range","range":"(0,001450 – 23,70) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-10:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,150 – 3291) mg/m3"},{"name":"范围","range":"(0,001450 – 23,70) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-10:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4756","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu-2-metoksyetylu","parameters":[{"name":"Zakres","range":"(0,090 – 513) mg/m3"},{"name":"Zakres","range":"(0,02 – 104,7) ppm"},{"name":"Zakres","range":"(0,00090 – 3,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-metoksyetylu\nZakres:\nZakres (0,090 – 513) mg/m3\nZakres (0,02 – 104,7) ppm\nZakres (0,00090 – 3,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2010 nr 1 (63), s. 185-192","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2010 nr 1 (63), s. 185-192"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu-2-metoksyetylu\nZakres:\nZakres (0,090 – 513) mg/m3\nZakres (0,02 – 104,7) ppm\nZakres (0,00090 – 3,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2010 nr 1 (63), s. 185-192 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu-2-metoksyetylu\nZakres:\nZakres (0,090 – 513) mg/m3\nZakres (0,02 – 104,7) ppm\nZakres (0,00090 – 3,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2010 nr 1 (63), s. 185-192","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,090 – 513) mg/m3"},{"name":"Range","range":"(0,02 – 104,7) ppm"},{"name":"Range","range":"(0,00090 – 3,70) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Range Podstawy i Metody Oceny Środowiska Pracy 2010 nr 1 (63), s. 185-192","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,090 – 513) mg/m3"},{"name":"范围","range":"(0,02 – 104,7) ppm"},{"name":"范围","range":"(0,00090 – 3,70) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2010 nr 1 (63), s. 185-192","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4757","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu izobutylu","parameters":[{"name":"Zakres","range":"(0,110 – 2527) mg/m3"},{"name":"Zakres","range":"(0,00110 – 18,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izobutylu\nZakres:\nZakres (0,110 – 2527) mg/m3\nZakres (0,00110 – 18,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-11:2008","norm_bases":["PN-Z-04119-11:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu izobutylu\nZakres:\nZakres (0,110 – 2527) mg/m3\nZakres (0,00110 – 18,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-11:2008 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu izobutylu\nZakres:\nZakres (0,110 – 2527) mg/m3\nZakres (0,00110 – 18,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-11:2008","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isobutyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,110 – 2527) mg/m3"},{"name":"Range","range":"(0,00110 – 18,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Isobutyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-11:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,110 – 2527) mg/m3"},{"name":"范围","range":"(0,00110 – 18,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙酸异丁酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-11:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙酸异丁酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4758","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu metylu","parameters":[{"name":"Zakres","range":"(0,080 – 1820) mg/m3"},{"name":"Zakres","range":"(0,00110 – 9,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu metylu\nZakres:\nZakres (0,080 – 1820) mg/m3\nZakres (0,00110 – 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu metylu\nZakres:\nZakres (0,080 – 1820) mg/m3\nZakres (0,00110 – 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu metylu\nZakres:\nZakres (0,080 – 1820) mg/m3\nZakres (0,00110 – 9,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,080 – 1820) mg/m3"},{"name":"Range","range":"(0,00110 – 9,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Methyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,080 – 1820) mg/m3"},{"name":"范围","range":"(0,00110 – 9,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4759","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu propylu","parameters":[{"name":"Zakres","range":"(0,090 – 3020) mg/m3"},{"name":"Zakres","range":"(0,00090 – 15,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu propylu\nZakres:\nZakres (0,090 – 3020) mg/m3\nZakres (0,00090 – 15,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-11:2008","norm_bases":["PN-Z-04119-11:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu propylu\nZakres:\nZakres (0,090 – 3020) mg/m3\nZakres (0,00090 – 15,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-11:2008 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu propylu\nZakres:\nZakres (0,090 – 3020) mg/m3\nZakres (0,00090 – 15,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-11:2008","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of propyl acetate","parameters_en":[{"name":"Range","range":"(0,090 – 3020) mg/m3"},{"name":"Range","range":"(0,00090 – 15,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of propyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-11:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,090 – 3020) mg/m3"},{"name":"范围","range":"(0,00090 – 15,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-11:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c475a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość etylotoluenu (mieszanina izomerów):","parameters":[{"name":"2-etylotoluen"},{"name":"3-etylotoluen"},{"name":"4-etylotoluen"},{"name":"Zakres","range":"(0,067 – 600,000) mg/m3"},{"name":"Zakres","range":"(0,001 – 3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etylotoluenu (mieszanina izomerów):\nZakres:\n2-etylotoluen\n3-etylotoluen\n4-etylotoluen\nZakres (0,067 – 600,000) mg/m3\nZakres (0,001 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-5:1998","norm_bases":["PN-Z-04016-5:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość etylotoluenu (mieszanina izomerów):\nZakres:\n2-etylotoluen\n3-etylotoluen\n4-etylotoluen\nZakres (0,067 – 600,000) mg/m3\nZakres (0,001 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-5:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc etylotoluenu (mieszanina izomerow):\nZakres:\n2-etylotoluen\n3-etylotoluen\n4-etylotoluen\nZakres (0,067 – 600,000) mg/m3\nZakres (0,001 – 3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-5:1998","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"2-ethyltoluene"},{"name":"3-ethyltoluene"},{"name":"4-ethyltoluene"},{"name":"Range","range":"(0,067 – 600,000) mg/m3"},{"name":"Range","range":"(0,001 – 3,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) 2-ethyltoluene 3-ethyltoluene 4-ethyltoluene Range Range PN-Z-04016-5:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"2-乙基甲苯"},{"name":"3-乙基甲苯"},{"name":"4-乙基甲苯"},{"name":"范围","range":"(0,067 – 600,000) mg/m3"},{"name":"范围","range":"(0,001 – 3,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 2-乙基甲苯 3-乙基甲苯 4-乙基甲苯 范围 范围 PN-Z-04016-5:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c475b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Suma stężenia/zawartości etylotoluenu (mieszanina izomerów) (z obliczeń)","parameters":[{"name":"Zakres","range":"(0,0670-1800) mg/m3"},{"name":"Zakres","range":"(0,0010 – 9,0) mg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości etylotoluenu (mieszanina izomerów) (z obliczeń)\nZakres:\nZakres (0,0670-1800) mg/m3\nZakres (0,0010 – 9,0) mg w próbce","reference":"PN-Z-04016-5:1998","norm_bases":["PN-Z-04016-5:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Suma stężenia/zawartości etylotoluenu (mieszanina izomerów) (z obliczeń)\nZakres:\nZakres (0,0670-1800) mg/m3\nZakres (0,0010 – 9,0) mg w próbce PN-Z-04016-5:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Suma stezenia/zawartosci etylotoluenu (mieszanina izomerow) (z obliczen)\nZakres:\nZakres (0,0670-1800) mg/m3\nZakres (0,0010 – 9,0) mg w probce PN-Z-04016-5:1998","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0670-1800) mg/m3"},{"name":"Range","range":"(0,0010 – 9,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Range Range PN-Z-04016-5:1998","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670-1800) mg/m3"},{"name":"范围","range":"(0,0010 – 9,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 范围 范围 PN-Z-04016-5:1998","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c475c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość pentanu","parameters":[{"name":"Zakres","range":"(0,340 – 9089) mg/m3"},{"name":"Zakres","range":"(0,0010 – 16,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość pentanu\nZakres:\nZakres (0,340 – 9089) mg/m3\nZakres (0,0010 – 16,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość pentanu\nZakres:\nZakres (0,340 – 9089) mg/m3\nZakres (0,0010 – 16,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc pentanu\nZakres:\nZakres (0,340 – 9089) mg/m3\nZakres (0,0010 – 16,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentane concentration/content","parameters_en":[{"name":"Range","range":"(0,340 – 9089) mg/m3"},{"name":"Range","range":"(0,0010 – 16,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Pentane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,340 – 9089) mg/m3"},{"name":"范围","range":"(0,0010 – 16,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c475d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość oktanu","parameters":[{"name":"Zakres","range":"(0,10 – 2277) mg/m3"},{"name":"Zakres","range":"(0,0010 – 4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość oktanu\nZakres:\nZakres (0,10 – 2277) mg/m3\nZakres (0,0010 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04166-02:1986","norm_bases":["PN-Z-04166-02:1986"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość oktanu\nZakres:\nZakres (0,10 – 2277) mg/m3\nZakres (0,0010 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04166-02:1986 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc oktanu\nZakres:\nZakres (0,10 – 2277) mg/m3\nZakres (0,0010 – 4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04166-02:1986","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Octane concentration/content","parameters_en":[{"name":"Range","range":"(0,10 – 2277) mg/m3"},{"name":"Range","range":"(0,0010 – 4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Octane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04166-02:1986","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10 – 2277) mg/m3"},{"name":"范围","range":"(0,0010 – 4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 辛烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04166-02:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"辛烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c475e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,0670 – 920) mg/m3"},{"name":"Zakres","range":"(0,0010 – 4,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,0670 – 920) mg/m3\nZakres (0,0010 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999 nr 22, s. 91-95","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999 nr 22, s. 91-95"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość fenolu\nZakres:\nZakres (0,0670 – 920) mg/m3\nZakres (0,0010 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999 nr 22, s. 91-95 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc fenolu\nZakres:\nZakres (0,0670 – 920) mg/m3\nZakres (0,0010 – 4,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999 nr 22, s. 91-95","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration/content","parameters_en":[{"name":"Range","range":"(0,0670 – 920) mg/m3"},{"name":"Range","range":"(0,0010 – 4,6) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Phenol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1999 nr 22, s. 91-95","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0670 – 920) mg/m3"},{"name":"范围","range":"(0,0010 – 4,6) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1999 nr 22, s. 91-95","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c475f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0280 – 14) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,103) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0280 – 14) mg/m3\nZakres (0,0010 – 0,103) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","norm_bases":["EV-IR-52 wyd. 1 z dn. 14.10.2019 r.","na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0280 – 14) mg/m3\nZakres (0,0010 – 0,103) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,0280 – 14) mg/m3\nZakres (0,0010 – 0,103) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,0280 – 14) mg/m3"},{"name":"Range","range":"(0,0010 – 0,103) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Formaldehyde concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0280 – 14) mg/m3"},{"name":"范围","range":"(0,0010 – 0,103) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 甲醛浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"甲醛浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4760","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)","parameters":[{"name":"Zakres","range":"(0,060 – 1027) mg/m3"},{"name":"Zakres","range":"(0,00090 – 7,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,060 – 1027) mg/m3\nZakres (0,00090 – 7,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04368:2008","norm_bases":["PN-Z-04368:2008"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,060 – 1027) mg/m3\nZakres (0,00090 – 7,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04368:2008 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,060 – 1027) mg/m3\nZakres (0,00090 – 7,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04368:2008","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,060 – 1027) mg/m3"},{"name":"Range","range":"(0,00090 – 7,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04368:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,060 – 1027) mg/m3"},{"name":"范围","range":"(0,00090 – 7,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04368:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4761","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu izopropylu","parameters":[{"name":"Zakres","range":"(0,060 – 2111) mg/m3"},{"name":"Zakres","range":"(0,00090 – 15,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izopropylu\nZakres:\nZakres (0,060 – 2111) mg/m3\nZakres (0,00090 – 15,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-7:2006","norm_bases":["PN-Z-04119-7:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu izopropylu\nZakres:\nZakres (0,060 – 2111) mg/m3\nZakres (0,00090 – 15,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-7:2006 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu izopropylu\nZakres:\nZakres (0,060 – 2111) mg/m3\nZakres (0,00090 – 15,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-7:2006","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of isopropyl acetate","parameters_en":[{"name":"Range","range":"(0,060 – 2111) mg/m3"},{"name":"Range","range":"(0,00090 – 15,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of isopropyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-7:2006","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,060 – 2111) mg/m3"},{"name":"范围","range":"(0,00090 – 15,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-7:2006","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4762","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość chlorobenzenu","parameters":[{"name":"Zakres","range":"(0,110 – 861) mg/m3"},{"name":"Zakres","range":"(0,00160 – 6,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chlorobenzenu\nZakres:\nZakres (0,110 – 861) mg/m3\nZakres (0,00160 – 6,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04022-3:2001","norm_bases":["PN-Z-04022-3:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość chlorobenzenu\nZakres:\nZakres (0,110 – 861) mg/m3\nZakres (0,00160 – 6,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04022-3:2001 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc chlorobenzenu\nZakres:\nZakres (0,110 – 861) mg/m3\nZakres (0,00160 – 6,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04022-3:2001","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene concentration/content","parameters_en":[{"name":"Range","range":"(0,110 – 861) mg/m3"},{"name":"Range","range":"(0,00160 – 6,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Chlorobenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04022-3:2001","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,110 – 861) mg/m3"},{"name":"范围","range":"(0,00160 – 6,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 氯苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04022-3:2001","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"氯苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4763","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość chloroformu","parameters":[{"name":"Zakres","range":"(0,40 – 500) mg/m3"},{"name":"Zakres","range":"(0,00120 – 0,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroformu\nZakres:\nZakres (0,40 – 500) mg/m3\nZakres (0,00120 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04187-02:1988","norm_bases":["PN-Z-04187-02:1988"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość chloroformu\nZakres:\nZakres (0,40 – 500) mg/m3\nZakres (0,00120 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04187-02:1988 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc chloroformu\nZakres:\nZakres (0,40 – 500) mg/m3\nZakres (0,00120 – 0,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04187-02:1988","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroform","parameters_en":[{"name":"Range","range":"(0,40 – 500) mg/m3"},{"name":"Range","range":"(0,00120 – 0,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of chloroform Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04187-02:1988","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,40 – 500) mg/m3"},{"name":"范围","range":"(0,00120 – 0,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04187-02:1988","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4764","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość akrylanu butylu","parameters":[{"name":"Zakres","range":"(0,120 – 333) mg/m3"},{"name":"Zakres","range":"(0,00120 – 2,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylanu butylu\nZakres:\nZakres (0,120 – 333) mg/m3\nZakres (0,00120 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-06:1986","norm_bases":["PN-Z-04113-06:1986"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość akrylanu butylu\nZakres:\nZakres (0,120 – 333) mg/m3\nZakres (0,00120 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-06:1986 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc akrylanu butylu\nZakres:\nZakres (0,120 – 333) mg/m3\nZakres (0,00120 – 2,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-06:1986","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butyl acrylate","parameters_en":[{"name":"Range","range":"(0,120 – 333) mg/m3"},{"name":"Range","range":"(0,00120 – 2,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of butyl acrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-06:1986","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,120 – 333) mg/m3"},{"name":"范围","range":"(0,00120 – 2,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-06:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4765","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość kumenu (izopropylobenzenu)","parameters":[{"name":"Zakres","range":"(0,070 – 569) mg/m3"},{"name":"Zakres","range":"(0,00100 – 4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kumenu (izopropylobenzenu)\nZakres:\nZakres (0,070 – 569) mg/m3\nZakres (0,00100 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-6:1998","norm_bases":["PN-Z-04016-6:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość kumenu (izopropylobenzenu)\nZakres:\nZakres (0,070 – 569) mg/m3\nZakres (0,00100 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-6:1998 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc kumenu (izopropylobenzenu)\nZakres:\nZakres (0,070 – 569) mg/m3\nZakres (0,00100 – 4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-6:1998","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cumene (isopropylbenzene)","parameters_en":[{"name":"Range","range":"(0,070 – 569) mg/m3"},{"name":"Range","range":"(0,00100 – 4,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of cumene (isopropylbenzene) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-6:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,070 – 569) mg/m3"},{"name":"范围","range":"(0,00100 – 4,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-6:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4766","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)","parameters":[{"name":"Zakres","range":"(0,024 – 527) mg/m3"},{"name":"Zakres","range":"(0,01 – 137) ppm"},{"name":"Zakres","range":"(0,000940 – 3,80) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,024 – 527) mg/m3\nZakres (0,01 – 137) ppm\nZakres (0,000940 – 3,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994","norm_bases":["PN-Z-04029-01:1981","NIOSH Method 1010, Issue 2, 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,024 – 527) mg/m3\nZakres (0,01 – 137) ppm\nZakres (0,000940 – 3,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,024 – 527) mg/m3\nZakres (0,01 – 137) ppm\nZakres (0,000940 – 3,80) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,024 – 527) mg/m3"},{"name":"Range","range":"(0,01 – 137) ppm"},{"name":"Range","range":"(0,000940 – 3,80) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,024 – 527) mg/m3"},{"name":"范围","range":"(0,01 – 137) ppm"},{"name":"范围","range":"(0,000940 – 3,80) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4767","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-(2-butoksyetoksy) etanolu","parameters":[{"name":"Zakres","range":"(0,150 – 637) mg/m3"},{"name":"Zakres","range":"(0,00450 – 4,59) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,150 – 637) mg/m3\nZakres (0,00450 – 4,59) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04399:2011","norm_bases":["PN-Z-04399:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,150 – 637) mg/m3\nZakres (0,00450 – 4,59) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04399:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,150 – 637) mg/m3\nZakres (0,00450 – 4,59) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04399:2011","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-(2-butoxyethoxy) ethanol","parameters_en":[{"name":"Range","range":"(0,150 – 637) mg/m3"},{"name":"Range","range":"(0,00450 – 4,59) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-(2-butoxyethoxy) ethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04399:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,150 – 637) mg/m3"},{"name":"范围","range":"(0,00450 – 4,59) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04399:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4768","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(0,210 – 444) mg/m3"},{"name":"Zakres","range":"(0,00650 – 3,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,210 – 444) mg/m3\nZakres (0,00650 – 3,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 str. 55-59","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 str. 55-59"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,210 – 444) mg/m3\nZakres (0,00650 – 3,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 str. 55-59 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (0,210 – 444) mg/m3\nZakres (0,00650 – 3,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17 str. 55-59","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol concentration/content","parameters_en":[{"name":"Range","range":"(0,210 – 444) mg/m3"},{"name":"Range","range":"(0,00650 – 3,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 str. 55-59","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,210 – 444) mg/m3"},{"name":"范围","range":"(0,00650 – 3,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙二醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 str. 55-59","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4769","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-metoksyetanolu","parameters":[{"name":"Zakres","range":"(0,10 – 430) mg/m3"},{"name":"Zakres","range":"(0,03 – 136) ppm"},{"name":"Zakres","range":"(0,0030 – 3,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-metoksyetanolu\nZakres:\nZakres (0,10 – 430) mg/m3\nZakres (0,03 – 136) ppm\nZakres (0,0030 – 3,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04167-02:1986 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63) str. 169-175","norm_bases":["PN-Z-04167-02:1986 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63) str. 169-175"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-metoksyetanolu\nZakres:\nZakres (0,10 – 430) mg/m3\nZakres (0,03 – 136) ppm\nZakres (0,0030 – 3,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04167-02:1986 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63) str. 169-175 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-metoksyetanolu\nZakres:\nZakres (0,10 – 430) mg/m3\nZakres (0,03 – 136) ppm\nZakres (0,0030 – 3,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04167-02:1986 Podstawy i Metody Oceny Srodowiska Pracy 2010, nr 1 (63) str. 169-175","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-methoxyethanol","parameters_en":[{"name":"Range","range":"(0,10 – 430) mg/m3"},{"name":"Range","range":"(0,03 – 136) ppm"},{"name":"Range","range":"(0,0030 – 3,1) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-methoxyethanol Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04167-02:1986 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63) str. 169-175","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,10 – 430) mg/m3"},{"name":"范围","range":"(0,03 – 136) ppm"},{"name":"范围","range":"(0,0030 – 3,1) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04167-02:1986 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63) str. 169-175","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c476a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość krezolu – mieszanina izomerów","parameters":[{"name":"Zakres","range":"(0,340 – 350) mg/m3"},{"name":"Zakres","range":"(0,00170 – 0,42) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość krezolu – mieszanina izomerów\nZakres:\nZakres (0,340 – 350) mg/m3\nZakres (0,00170 – 0,42) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 str. 91-95","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 str. 91-95"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość krezolu – mieszanina izomerów\nZakres:\nZakres (0,340 – 350) mg/m3\nZakres (0,00170 – 0,42) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 str. 91-95 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc krezolu – mieszanina izomerow\nZakres:\nZakres (0,340 – 350) mg/m3\nZakres (0,00170 – 0,42) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 str. 91-95","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cresol concentration/content – mixture of isomers","parameters_en":[{"name":"Range","range":"(0,340 – 350) mg/m3"},{"name":"Range","range":"(0,00170 – 0,42) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Cresol concentration/content – mixture of isomers Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 str. 91-95","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,340 – 350) mg/m3"},{"name":"范围","range":"(0,00170 – 0,42) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 str. 91-95","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c476b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość kwasu akrylowego","parameters":[{"name":"Zakres","range":"(0,67 – 722) mg/m3"},{"name":"Zakres","range":"(0,22 – 242) ppm"},{"name":"Zakres","range":"(0,020 – 5,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (0,67 – 722) mg/m3\nZakres (0,22 – 242) ppm\nZakres (0,020 – 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-08:1992","norm_bases":["PN-Z-04113-08:1992"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (0,67 – 722) mg/m3\nZakres (0,22 – 242) ppm\nZakres (0,020 – 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-08:1992 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc kwasu akrylowego\nZakres:\nZakres (0,67 – 722) mg/m3\nZakres (0,22 – 242) ppm\nZakres (0,020 – 5,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-08:1992","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,67 – 722) mg/m3"},{"name":"Range","range":"(0,22 – 242) ppm"},{"name":"Range","range":"(0,020 – 5,2) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Acrylic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04113-08:1992","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,67 – 722) mg/m3"},{"name":"范围","range":"(0,22 – 242) ppm"},{"name":"范围","range":"(0,020 – 5,2) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04113-08:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c476c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość trichloroetenu","parameters":[{"name":"Zakres","range":"(0,040 – 1138) mg/m3"},{"name":"Zakres","range":"(0,0010 – 8,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość trichloroetenu\nZakres:\nZakres (0,040 – 1138) mg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2","norm_bases":["NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość trichloroetenu\nZakres:\nZakres (0,040 – 1138) mg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc trichloroetenu\nZakres:\nZakres (0,040 – 1138) mg/m3\nZakres (0,0010 – 8,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichloroethene concentration/content","parameters_en":[{"name":"Range","range":"(0,040 – 1138) mg/m3"},{"name":"Range","range":"(0,0010 – 8,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Trichloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,040 – 1138) mg/m3"},{"name":"范围","range":"(0,0010 – 8,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 三氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"三氯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c476d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,32 – 400) mg/m3"},{"name":"Zakres","range":"(0,0012 – 0,3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (0,32 – 400) mg/m3\nZakres (0,0012 – 0,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04476:2016-10","norm_bases":["PN-Z-04476:2016-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość metanolu\nZakres:\nZakres (0,32 – 400) mg/m3\nZakres (0,0012 – 0,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04476:2016-10 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc metanolu\nZakres:\nZakres (0,32 – 400) mg/m3\nZakres (0,0012 – 0,3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04476:2016-10","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol concentration/content","parameters_en":[{"name":"Range","range":"(0,32 – 400) mg/m3"},{"name":"Range","range":"(0,0012 – 0,3) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Methanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04476:2016-10","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,32 – 400) mg/m3"},{"name":"范围","range":"(0,0012 – 0,3) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 甲醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04476:2016-10","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"甲醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c476e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,021 – 138) mg/m3"},{"name":"Zakres","range":"(0,01 – 55) ppm"},{"name":"Zakres","range":"(0,001 – 1,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,021 – 138) mg/m3\nZakres (0,01 – 55) ppm\nZakres (0,001 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,021 – 138) mg/m3\nZakres (0,01 – 55) ppm\nZakres (0,001 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (0,021 – 138) mg/m3\nZakres (0,01 – 55) ppm\nZakres (0,001 – 1,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,021 – 138) mg/m3"},{"name":"Range","range":"(0,01 – 55) ppm"},{"name":"Range","range":"(0,001 – 1,00) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Acetic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04323:2004","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,021 – 138) mg/m3"},{"name":"范围","range":"(0,01 – 55) ppm"},{"name":"范围","range":"(0,001 – 1,00) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 乙酸的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"乙酸的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c476f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość propan-1-olu","parameters":[{"name":"Zakres","range":"(0,220 – 840) mg/m3"},{"name":"Zakres","range":"(0,00110 – 4,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-1-olu\nZakres:\nZakres (0,220 – 840) mg/m3\nZakres (0,00110 – 4,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1998, nr 19 str. 160-164","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1998, nr 19 str. 160-164"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość propan-1-olu\nZakres:\nZakres (0,220 – 840) mg/m3\nZakres (0,00110 – 4,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1998, nr 19 str. 160-164 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc propan-1-olu\nZakres:\nZakres (0,220 – 840) mg/m3\nZakres (0,00110 – 4,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1998, nr 19 str. 160-164","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of propan-1-ol","parameters_en":[{"name":"Range","range":"(0,220 – 840) mg/m3"},{"name":"Range","range":"(0,00110 – 4,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of propan-1-ol Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1998, nr 19 str. 160-164","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,220 – 840) mg/m3"},{"name":"范围","range":"(0,00110 – 4,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1998, nr 19 str. 160-164","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4770","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość furfuralu","parameters":[{"name":"Zakres","range":"(0,110 – 210) mg/m3"},{"name":"Zakres","range":"(0,00110 – 2,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość furfuralu\nZakres:\nZakres (0,110 – 210) mg/m3\nZakres (0,00110 – 2,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04045-09:1992","norm_bases":["PN-Z-04045-09:1992"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość furfuralu\nZakres:\nZakres (0,110 – 210) mg/m3\nZakres (0,00110 – 2,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04045-09:1992 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc furfuralu\nZakres:\nZakres (0,110 – 210) mg/m3\nZakres (0,00110 – 2,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04045-09:1992","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,110 – 210) mg/m3"},{"name":"Range","range":"(0,00110 – 2,10) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04045-09:1992","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,110 – 210) mg/m3"},{"name":"范围","range":"(0,00110 – 2,10) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04045-09:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4771","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość sewofluranu","parameters":[{"name":"Zakres","range":"(3,20 – 200) mg/m3"},{"name":"Zakres","range":"(0,0160 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość sewofluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04429:2011","norm_bases":["PN-Z-04429:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość sewofluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04429:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc sewofluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04429:2011","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sevoflurane concentration/content","parameters_en":[{"name":"Range","range":"(3,20 – 200) mg/m3"},{"name":"Range","range":"(0,0160 – 1,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Sevoflurane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04429:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(3,20 – 200) mg/m3"},{"name":"范围","range":"(0,0160 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 七氟烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04429:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"七氟烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4772","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość dezfluranu","parameters":[{"name":"Zakres","range":"(3,20 – 200) mg/m3"},{"name":"Zakres","range":"(0,0160 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość dezfluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04422:2010","norm_bases":["PN-Z-04422:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość dezfluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04422:2010 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc dezfluranu\nZakres:\nZakres (3,20 – 200) mg/m3\nZakres (0,0160 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04422:2010","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of desflurane","parameters_en":[{"name":"Range","range":"(3,20 – 200) mg/m3"},{"name":"Range","range":"(0,0160 – 1,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of desflurane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04422:2010","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(3,20 – 200) mg/m3"},{"name":"范围","range":"(0,0160 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04422:2010","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4773","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość nafty","parameters":[{"name":"Zakres","range":"(1,850 – 625) mg/m3"},{"name":"Zakres","range":"(0,0370 – 4,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość nafty\nZakres:\nZakres (1,850 – 625) mg/m3\nZakres (0,0370 – 4,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH Method 1550, Issue 2, 15 August 1994","norm_bases":["NIOSH Method 1550, Issue 2, 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość nafty\nZakres:\nZakres (1,850 – 625) mg/m3\nZakres (0,0370 – 4,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH Method 1550, Issue 2, 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc nafty\nZakres:\nZakres (1,850 – 625) mg/m3\nZakres (0,0370 – 4,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH Method 1550, Issue 2, 15 August 1994","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kerosene concentration/content","parameters_en":[{"name":"Range","range":"(1,850 – 625) mg/m3"},{"name":"Range","range":"(0,0370 – 4,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Kerosene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH Method 1550, Issue 2, 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(1,850 – 625) mg/m3"},{"name":"范围","range":"(0,0370 – 4,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 煤油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH Method 1550, Issue 2, 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"煤油的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4774","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość akrylaldehydu (akroleiny)","parameters":[{"name":"Zakres","range":"(0,0040– 4,10) mg/m3"},{"name":"Zakres","range":"(0,01 – 1,76) ppm"},{"name":"Zakres","range":"(0,000240 – 0,030) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040– 4,10) mg/m3\nZakres (0,01 – 1,76) ppm\nZakres (0,000240 – 0,030) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04045-06:1982","norm_bases":["PN-Z-04045-06:1982"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040– 4,10) mg/m3\nZakres (0,01 – 1,76) ppm\nZakres (0,000240 – 0,030) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04045-06:1982 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040– 4,10) mg/m3\nZakres (0,01 – 1,76) ppm\nZakres (0,000240 – 0,030) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04045-06:1982","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acrylaldehyde (acrolein)","parameters_en":[{"name":"Range","range":"(0,0040– 4,10) mg/m3"},{"name":"Range","range":"(0,01 – 1,76) ppm"},{"name":"Range","range":"(0,000240 – 0,030) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of acrylaldehyde (acrolein) Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04045-06:1982","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,0040– 4,10) mg/m3"},{"name":"范围","range":"(0,01 – 1,76) ppm"},{"name":"范围","range":"(0,000240 – 0,030) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04045-06:1982","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4775","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość acetonitrylu","parameters":[{"name":"Zakres","range":"(4,7 – 300) mg/m3"},{"name":"Zakres","range":"(0,047 – 1,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetonitrylu\nZakres:\nZakres (4,7 – 300) mg/m3\nZakres (0,047 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04244-2:1996","norm_bases":["PN-Z-04244-2:1996"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość acetonitrylu\nZakres:\nZakres (4,7 – 300) mg/m3\nZakres (0,047 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04244-2:1996 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc acetonitrylu\nZakres:\nZakres (4,7 – 300) mg/m3\nZakres (0,047 – 1,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04244-2:1996","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acetonitrile","parameters_en":[{"name":"Range","range":"(4,7 – 300) mg/m3"},{"name":"Range","range":"(0,047 – 1,5) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of acetonitrile Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04244-2:1996","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(4,7 – 300) mg/m3"},{"name":"范围","range":"(0,047 – 1,5) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04244-2:1996","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4776","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość acetaldehydu","parameters":[{"name":"Zakres","range":"(0,083 – 200) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetaldehydu\nZakres:\nZakres (0,083 – 200) mg/m3\nZakres (0,0010 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH METHOD 2538, Issue 2, dated 15 August 1994","norm_bases":["NIOSH METHOD 2538, Issue 2, dated 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość acetaldehydu\nZakres:\nZakres (0,083 – 200) mg/m3\nZakres (0,0010 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH METHOD 2538, Issue 2, dated 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc acetaldehydu\nZakres:\nZakres (0,083 – 200) mg/m3\nZakres (0,0010 – 0,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH METHOD 2538, Issue 2, dated 15 August 1994","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acetaldehyde","parameters_en":[{"name":"Range","range":"(0,083 – 200) mg/m3"},{"name":"Range","range":"(0,0010 – 0,6) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of acetaldehyde Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH METHOD 2538, Issue 2, dated 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,083 – 200) mg/m3"},{"name":"范围","range":"(0,0010 – 0,6) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH METHOD 2538, Issue 2, dated 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4777","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość cykloheksanolu","parameters":[{"name":"Zakres","range":"(0,97 – 496) mg/m3"},{"name":"Zakres","range":"(0,0098 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanolu\nZakres:\nZakres (0,97 – 496) mg/m3\nZakres (0,0098 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH METHOD 1402, Issue 2, 15 August 1994","norm_bases":["NIOSH METHOD 1402, Issue 2, 15 August 1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość cykloheksanolu\nZakres:\nZakres (0,97 – 496) mg/m3\nZakres (0,0098 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH METHOD 1402, Issue 2, 15 August 1994 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc cykloheksanolu\nZakres:\nZakres (0,97 – 496) mg/m3\nZakres (0,0098 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH METHOD 1402, Issue 2, 15 August 1994","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cyclohexanol","parameters_en":[{"name":"Range","range":"(0,97 – 496) mg/m3"},{"name":"Range","range":"(0,0098 – 5) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of cyclohexanol Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH METHOD 1402, Issue 2, 15 August 1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,97 – 496) mg/m3"},{"name":"范围","range":"(0,0098 – 5) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH METHOD 1402, Issue 2, 15 August 1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4778","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość fenylometanolu (alkoholu benzylowego)","parameters":[{"name":"Zakres","range":"(0,25 – 500) mg/m3"},{"name":"Zakres","range":"(0,0059 – 12) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,25 – 500) mg/m3\nZakres (0,0059 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"OSHA Method PV2009","norm_bases":["OSHA Method PV2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,25 – 500) mg/m3\nZakres (0,0059 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) OSHA Method PV2009 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,25 – 500) mg/m3\nZakres (0,0059 – 12) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) OSHA Method PV2009","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of phenylmethanol (benzyl alcohol)","parameters_en":[{"name":"Range","range":"(0,25 – 500) mg/m3"},{"name":"Range","range":"(0,0059 – 12) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Concentration/content of phenylmethanol (benzyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range OSHA Method PV2009","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,25 – 500) mg/m3"},{"name":"范围","range":"(0,0059 – 12) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 OSHA Method PV2009","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4779","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu amylu (octanu pentylu)","parameters":[{"name":"Zakres","range":"(3,9 – 1000) mg/m3"},{"name":"Zakres","range":"(0,039 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu amylu (octanu pentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH METHOD 1450, Issue 3, 15 March 2003","norm_bases":["NIOSH METHOD 1450, Issue 3, 15 March 2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu amylu (octanu pentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu amylu (octanu pentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003","categories":["environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3,9 – 1000) mg/m3"},{"name":"Range","range":"(0,039 – 5) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH METHOD 1450, Issue 3, 15 March 2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(3,9 – 1000) mg/m3"},{"name":"范围","range":"(0,039 – 5) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH METHOD 1450, Issue 3, 15 March 2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c477a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość octanu izoamylu (octanu izopentylu)","parameters":[{"name":"Zakres","range":"(3,9 – 1000) mg/m3"},{"name":"Zakres","range":"(0,039 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH METHOD 1450, Issue 3, 15 March 2003","norm_bases":["NIOSH METHOD 1450, Issue 3, 15 March 2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (3,9 – 1000) mg/m3\nZakres (0,039 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003","categories":["environment"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3,9 – 1000) mg/m3"},{"name":"Range","range":"(0,039 – 5) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH METHOD 1450, Issue 3, 15 March 2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(3,9 – 1000) mg/m3"},{"name":"范围","range":"(0,039 – 5) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH METHOD 1450, Issue 3, 15 March 2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c477b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-etyloheksan-1-olu","parameters":[{"name":"Zakres","range":"(0,42 – 260) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,3) mg w próbce"},{"name":"Zakres","range":"(0,08 – 48) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-etyloheksan-1-olu\nZakres:\nZakres (0,42 – 260) mg/m3\nZakres (0,010 – 1,3) mg w próbce\nZakres (0,08 – 48) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92) str. 149-160","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92) str. 149-160"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-etyloheksan-1-olu\nZakres:\nZakres (0,42 – 260) mg/m3\nZakres (0,010 – 1,3) mg w próbce\nZakres (0,08 – 48) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92) str. 149-160 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-etyloheksan-1-olu\nZakres:\nZakres (0,42 – 260) mg/m3\nZakres (0,010 – 1,3) mg w probce\nZakres (0,08 – 48) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2(92) str. 149-160","categories":["environment"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,42 – 260) mg/m3"},{"name":"Range","range":"(0,010 – 1,3) mg w próbce"},{"name":"Range","range":"(0,08 – 48) ppm"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92) str. 149-160","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(0,42 – 260) mg/m3"},{"name":"范围","range":"(0,010 – 1,3) mg w próbce"},{"name":"范围","range":"(0,08 – 48) ppm"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92) str. 149-160","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c477c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość 2-furylometanolu","parameters":[{"name":"Zakres","range":"(1,9 – 240) mg/m3"},{"name":"Zakres","range":"(0,019 – 1,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-furylometanolu\nZakres:\nZakres (1,9 – 240) mg/m3\nZakres (0,019 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04214-02:1990","norm_bases":["PN-Z-04214-02:1990"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość 2-furylometanolu\nZakres:\nZakres (1,9 – 240) mg/m3\nZakres (0,019 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04214-02:1990 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc 2-furylometanolu\nZakres:\nZakres (1,9 – 240) mg/m3\nZakres (0,019 – 1,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04214-02:1990","categories":["environment"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,9 – 240) mg/m3"},{"name":"Range","range":"(0,019 – 1,2) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04214-02:1990","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(1,9 – 240) mg/m3"},{"name":"范围","range":"(0,019 – 1,2) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04214-02:1990","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c477d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość izofluranu","parameters":[{"name":"Zakres","range":"(1,25 – 80) mg/m 3"},{"name":"Zakres","range":"(0,00625 – 0,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość izofluranu\nZakres:\nZakres (1,25 – 80) mg/m 3\nZakres (0,00625 – 0,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04423:2011","norm_bases":["PN-Z-04423:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość izofluranu\nZakres:\nZakres (1,25 – 80) mg/m 3\nZakres (0,00625 – 0,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04423:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc izofluranu\nZakres:\nZakres (1,25 – 80) mg/m 3\nZakres (0,00625 – 0,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04423:2011","categories":["environment"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isoflurane concentration/content","parameters_en":[{"name":"Range","range":"(1,25 – 80) mg/m 3"},{"name":"Range","range":"(0,00625 – 0,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Isoflurane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04423:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(1,25 – 80) mg/m 3"},{"name":"范围","range":"(0,00625 – 0,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 异氟烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04423:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品","methodology_zh":"异氟烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c477e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały","methodology":"Stężenie/zawartość enfluranu","parameters":[{"name":"Zakres","range":"(1,25 – 80) mg/m3"},{"name":"Zakres","range":"(0,00625 – 0,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość enfluranu\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,00625 – 0,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2023, nr 3 (117), 95-122","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2023, nr 3 (117), 95-122"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na sorbent stały Stężenie/zawartość enfluranu\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,00625 – 0,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2023, nr 3 (117), 95-122 Srodowisko pracy − powietrze − probki powietrza pobrane na sorbent staly Stezenie/zawartosc enfluranu\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,00625 – 0,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2023, nr 3 (117), 95-122","categories":["environment"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,25 – 80) mg/m3"},{"name":"Range","range":"(0,00625 – 0,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on solid sorbent Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2023, nr 3 (117), 95-122","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air − air samples collected on solid sorbent","parameters_zh":[{"name":"范围","range":"(1,25 – 80) mg/m3"},{"name":"范围","range":"(0,00625 – 0,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2023, nr 3 (117), 95-122","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 − 空气 − 用固体吸附剂采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c477f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/m3"},{"name":"Zakres","range":"(0,20 – 4,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,20 – 4,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,20 – 4,0) mg w próbce\nMetoda spektrofotometryczna PN-Z-04450:2014-08 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,20 – 4,0) mg w probce\nMetoda spektrofotometryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/m3"},{"name":"Range","range":"(0,20 – 4,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Hydrogen chloride concentration/content Spectrophotometric method Range Range PN-Z-04450:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/m3"},{"name":"范围","range":"(0,20 – 4,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 氯化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04450:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4780","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr(VI)","parameters":[{"name":"Zakres","range":"(0,0005 – 0,027) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,020) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,0005 – 0,027) mg/m3\nZakres (0,0005 – 0,020) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04126-03:1987","norm_bases":["PN-Z-04126-03:1987"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,0005 – 0,027) mg/m3\nZakres (0,0005 – 0,020) mg w próbce\nMetoda spektrofotometryczna PN-Z-04126-03:1987 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc zwiazkow chromu (VI) – w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,0005 – 0,027) mg/m3\nZakres (0,0005 – 0,020) mg w probce\nMetoda spektrofotometryczna PN-Z-04126-03:1987","categories":["environment"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0005 – 0,027) mg/m3"},{"name":"Range","range":"(0,0005 – 0,020) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Spectrophotometric method Range Range PN-Z-04126-03:1987","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,027) mg/m3"},{"name":"范围","range":"(0,0005 – 0,020) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 分光光度法 范围 范围 PN-Z-04126-03:1987","technique_zh":"分光光度法","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4781","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chlorku amonu","parameters":[{"name":"Zakres","range":"(0,820 – 31,60) mg/m3"},{"name":"Zakres","range":"(0,0490 – 1,90) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorku amonu\nZakres:\nZakres (0,820 – 31,60) mg/m3\nZakres (0,0490 – 1,90) mg w próbce\nMetoda spektrofotometryczna","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 16 str. 39-42","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 16 str. 39-42"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość chlorku amonu\nZakres:\nZakres (0,820 – 31,60) mg/m3\nZakres (0,0490 – 1,90) mg w próbce\nMetoda spektrofotometryczna Podstawy i Metody Oceny Środowiska Pracy 1997, nr 16 str. 39-42 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc chlorku amonu\nZakres:\nZakres (0,820 – 31,60) mg/m3\nZakres (0,0490 – 1,90) mg w probce\nMetoda spektrofotometryczna Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 16 str. 39-42","categories":["environment"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of ammonium chloride","parameters_en":[{"name":"Range","range":"(0,820 – 31,60) mg/m3"},{"name":"Range","range":"(0,0490 – 1,90) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of ammonium chloride Spectrophotometric method Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 16 str. 39-42","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,820 – 31,60) mg/m3"},{"name":"范围","range":"(0,0490 – 1,90) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 分光光度法 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 16 str. 39-42","technique_zh":"分光光度法","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4782","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość 10 Hydrat heptaoksotetraboranu sodu","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,050 – 67) mg/m3"},{"name":"Zakres","range":"(0,0480 – 2,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość 10 Hydrat heptaoksotetraboranu sodu\nZakres:\nfrakcja wdychalna\nZakres (0,050 – 67) mg/m3\nZakres (0,0480 – 2,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04235-3:2001","norm_bases":["PN-Z-04235-3:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość 10 Hydrat heptaoksotetraboranu sodu\nZakres:\nfrakcja wdychalna\nZakres (0,050 – 67) mg/m3\nZakres (0,0480 – 2,0) mg w próbce\nMetoda spektrofotometryczna PN-Z-04235-3:2001 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc 10 Hydrat heptaoksotetraboranu sodu\nZakres:\nfrakcja wdychalna\nZakres (0,050 – 67) mg/m3\nZakres (0,0480 – 2,0) mg w probce\nMetoda spektrofotometryczna PN-Z-04235-3:2001","categories":["environment"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,050 – 67) mg/m3"},{"name":"Range","range":"(0,0480 – 2,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Spectrophotometric method inhalable fraction Range Range PN-Z-04235-3:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,050 – 67) mg/m3"},{"name":"范围","range":"(0,0480 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 分光光度法 可吸入组分 范围 范围 PN-Z-04235-3:2001","technique_zh":"分光光度法","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4783","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,28 – 6,9) mg/m3"},{"name":"Zakres","range":"(0,2 – 5,0) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,28 – 6,9) mg/m3\nZakres (0,2 – 5,0) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"PN-Z-04108-05:2006","norm_bases":["PN-Z-04108-05:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,28 – 6,9) mg/m3\nZakres (0,2 – 5,0) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) PN-Z-04108-05:2006 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc oleju mineralnego wysokorafinowanego z wylaczeniem cieczy obrobkowych – frakcja wdychalna\nZakres:\nZakres (0,28 – 6,9) mg/m3\nZakres (0,2 – 5,0) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) PN-Z-04108-05:2006","categories":["environment","petro"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,28 – 6,9) mg/m3"},{"name":"Range","range":"(0,2 – 5,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Fourier transform infrared spectrometry (FT-IR) Range Range PN-Z-04108-05:2006","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,28 – 6,9) mg/m3"},{"name":"范围","range":"(0,2 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） 范围 范围 PN-Z-04108-05:2006","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a82eafc884ede9a1b2c4784","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,010 – 0,2) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,4) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,010 – 0,2) mg/m3\nZakres (0,005 – 0,4) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,010 – 0,2) mg/m3\nZakres (0,005 – 0,4) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,010 – 0,2) mg/m3\nZakres (0,005 – 0,4) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4 (74), str. 117-130","categories":["environment"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(0,010 – 0,2) mg/m3"},{"name":"Range","range":"(0,005 – 0,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction Fourier transform infrared spectrometry (FT-IR) Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,010 – 0,2) mg/m3"},{"name":"范围","range":"(0,005 – 0,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a82eafc884ede9a1b2c4785","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do worka z tworzywa sztucznego Środowisko ogólne – próbki gazów odlotowych - próbki biogazu - pobrane do worka z tworzywa sztucznego","methodology":"Stężenie tlenku diazotu (podtlenku azotu)","parameters":[{"name":"Zakres","range":"(3,7 – 3660) mg/m3"},{"name":"Zakres","range":"(2,0 – 1999,2) ppm"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","norm_bases":["EV-PB-18 wydanie 2 z dnia 13.01.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do worka z tworzywa sztucznego Środowisko ogólne – próbki gazów odlotowych - próbki biogazu - pobrane do worka z tworzywa sztucznego Stężenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) EV-PB-18 wydanie 2 z dnia 13.01.2026 r. Srodowisko pracy − powietrze − probki powietrza pobrane do worka z tworzywa sztucznego Srodowisko ogolne – probki gazow odlotowych - probki biogazu - pobrane do worka z tworzywa sztucznego Stezenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","categories":["environment","materials"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3,7 – 3660) mg/m3"},{"name":"Range","range":"(2,0 – 1999,2) ppm"}],"search_en":"Fourier transform infrared spectrometry (FT-IR) Range Range EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","technique_en":"Fourier transform infrared spectrometry (FT-IR)","parameters_zh":[{"name":"范围","range":"(3,7 – 3660) mg/m3"},{"name":"范围","range":"(2,0 – 1999,2) ppm"}],"search_zh":"傅里叶变换红外光谱法（FT-IR） 范围 范围 EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a82eafc884ede9a1b2c4786","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość ditlenku siarki (SO2)","parameters":[{"name":"Zakres","range":"(0,123 – 6,40) mg/m3"},{"name":"Zakres","range":"(0,046 – 2,41) ppm"},{"name":"Zakres","range":"(0,00160 – 0,0640) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku siarki (SO2)\nZakres:\nZakres (0,123 – 6,40) mg/m3\nZakres (0,046 – 2,41) ppm\nZakres (0,00160 – 0,0640) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001","norm_bases":["PN-Z-04015-12:1996","PN-Z-04015-12/Ap1:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość ditlenku siarki (SO2)\nZakres:\nZakres (0,123 – 6,40) mg/m3\nZakres (0,046 – 2,41) ppm\nZakres (0,00160 – 0,0640) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc ditlenku siarki (SO2)\nZakres:\nZakres (0,123 – 6,40) mg/m3\nZakres (0,046 – 2,41) ppm\nZakres (0,00160 – 0,0640) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,123 – 6,40) mg/m3"},{"name":"Range","range":"(0,046 – 2,41) ppm"},{"name":"Range","range":"(0,00160 – 0,0640) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Spectrophotometric method Range Range Range PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,123 – 6,40) mg/m3"},{"name":"范围","range":"(0,046 – 2,41) ppm"},{"name":"范围","range":"(0,00160 – 0,0640) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 分光光度法 范围 范围 范围 PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4787","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość kwasu mrówkowego","parameters":[{"name":"Zakres","range":"(0,490 – 16,60) mg/m3"},{"name":"Zakres","range":"(0,00625 – 0,20) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu mrówkowego\nZakres:\nZakres (0,490 – 16,60) mg/m3\nZakres (0,00625 – 0,20) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04196-02:1988","norm_bases":["PN-Z-04196-02:1988"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość kwasu mrówkowego\nZakres:\nZakres (0,490 – 16,60) mg/m3\nZakres (0,00625 – 0,20) mg w próbce\nMetoda spektrofotometryczna PN-Z-04196-02:1988 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc kwasu mrowkowego\nZakres:\nZakres (0,490 – 16,60) mg/m3\nZakres (0,00625 – 0,20) mg w probce\nMetoda spektrofotometryczna PN-Z-04196-02:1988","categories":["environment"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,490 – 16,60) mg/m3"},{"name":"Range","range":"(0,00625 – 0,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Formic acid concentration/content Spectrophotometric method Range Range PN-Z-04196-02:1988","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,490 – 16,60) mg/m3"},{"name":"范围","range":"(0,00625 – 0,20) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 甲酸的浓度/含量 分光光度法 范围 范围 PN-Z-04196-02:1988","technique_zh":"分光光度法","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品","methodology_zh":"甲酸的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4788","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających","methodology":"Stężenie/zawartość hydrazyny","parameters":[{"name":"Zakres","range":"(0,00130 – 0,040) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,03) ppm"},{"name":"Zakres","range":"(0,0000260 – 0,00080) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość hydrazyny\nZakres:\nZakres (0,00130 – 0,040) mg/m3\nZakres (0,001 – 0,03) ppm\nZakres (0,0000260 – 0,00080) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04148-02:1985","norm_bases":["PN-Z-04148-02:1985"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane do roztworów pochłaniających Stężenie/zawartość hydrazyny\nZakres:\nZakres (0,00130 – 0,040) mg/m3\nZakres (0,001 – 0,03) ppm\nZakres (0,0000260 – 0,00080) mg w próbce\nMetoda spektrofotometryczna PN-Z-04148-02:1985 Srodowisko pracy − powietrze − probki powietrza pobrane do roztworow pochlaniajacych Stezenie/zawartosc hydrazyny\nZakres:\nZakres (0,00130 – 0,040) mg/m3\nZakres (0,001 – 0,03) ppm\nZakres (0,0000260 – 0,00080) mg w probce\nMetoda spektrofotometryczna PN-Z-04148-02:1985","categories":["environment"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,00130 – 0,040) mg/m3"},{"name":"Range","range":"(0,001 – 0,03) ppm"},{"name":"Range","range":"(0,0000260 – 0,00080) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected into absorbing solutions Spectrophotometric method Range Range Range PN-Z-04148-02:1985","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air − air samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,00130 – 0,040) mg/m3"},{"name":"范围","range":"(0,001 – 0,03) ppm"},{"name":"范围","range":"(0,0000260 – 0,00080) mg w próbce"}],"search_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品 分光光度法 范围 范围 范围 PN-Z-04148-02:1985","technique_zh":"分光光度法","test_object_zh":"工作环境 － 空气 － 采集于吸收液中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4789","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/Zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,034 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,025 – 10,0) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,032 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,025 – 10,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/Zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,034 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w próbce\nfrakcja respirabilna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/Zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,034 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w próbce\nfrakcja respirabilna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/Zawartosc tlenkow zelaza – w przeliczeniu na Fe tlenek zelaza (III), tlenek zelaza (II), tetratlenek trizelaza\nZakres:\nfrakcja wdychalna\nZakres (0,034 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w probce\nfrakcja respirabilna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,025 – 10,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/Content of iron oxides – calculated as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,034 – 25,0) mg/m3"},{"name":"Range","range":"(0,025 – 10,0) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,032 – 25,0) mg/m3"},{"name":"Range","range":"(0,025 – 10,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/Content of iron oxides – calculated as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,034 – 25,0) mg/m3"},{"name":"范围","range":"(0,025 – 10,0) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,032 – 25,0) mg/m3"},{"name":"范围","range":"(0,025 – 10,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c478a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014 – 0,80) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,60) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0013 – 0,75) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,60) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nfrakcja respirabilna\nZakres (0,0013 – 0,75) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10","PN-Z-04472:2015-10/Ap1:2015-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nfrakcja respirabilna\nZakres (0,0013 – 0,75) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w probce\nfrakcja respirabilna\nZakres (0,0013 – 0,75) mg/m3\nZakres (0,0010 – 0,60) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","categories":["environment"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of manganese and its inorganic compounds – expressed as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014 – 0,80) mg/m3"},{"name":"Range","range":"(0,0010 – 0,60) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0013 – 0,75) mg/m3"},{"name":"Range","range":"(0,0010 – 0,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of manganese and its inorganic compounds – expressed as Mn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0014 – 0,80) mg/m3"},{"name":"范围","range":"(0,0010 – 0,60) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0013 – 0,75) mg/m3"},{"name":"范围","range":"(0,0010 – 0,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 锰及其无机化合物的浓度/含量 － 以 Mn 计 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"锰及其无机化合物的浓度/含量 － 以 Mn 计"},{"_id":"6a82eafc884ede9a1b2c478b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00010 – 0,0078 ) mg/m3"},{"name":"Zakres","range":"(0,00010 – 0,0075) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00010 – 0,0078 ) mg/m3\nZakres (0,00010 – 0,0075) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04102-3:2013-10","norm_bases":["PN-Z-04102-3:2013-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00010 – 0,0078 ) mg/m3\nZakres (0,00010 – 0,0075) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc kadmu i jego zwiazkow nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00010 – 0,0078 ) mg/m3\nZakres (0,00010 – 0,0075) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013-10","categories":["environment"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cadmium and its inorganic compounds – calculated as Cd","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,00010 – 0,0078 ) mg/m3"},{"name":"Range","range":"(0,00010 – 0,0075) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of cadmium and its inorganic compounds – calculated as Cd Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-Z-04102-3:2013-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00010 – 0,0078 ) mg/m3"},{"name":"范围","range":"(0,00010 – 0,0075) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 镉及其无机化合物的浓度/含量 － 以 Cd 计 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-Z-04102-3:2013-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"镉及其无机化合物的浓度/含量 － 以 Cd 计"},{"_id":"6a82eafc884ede9a1b2c478c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,0014 – 0,694) mg/m3"},{"name":"Zakres","range":"(0,0010– 0,50) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 0,694) mg/m3\nZakres (0,0010– 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","norm_bases":["PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 0,694) mg/m3\nZakres (0,0010– 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc niklu metalicznego\nZakres:\nZakres (0,0014 – 0,694) mg/m3\nZakres (0,0010– 0,50) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","categories":["materials","environment"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic nickel concentration/content","parameters_en":[{"name":"Range","range":"(0,0014 – 0,694) mg/m3"},{"name":"Range","range":"(0,0010– 0,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Metallic nickel concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0014 – 0,694) mg/m3"},{"name":"范围","range":"(0,0010– 0,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 金属镍的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"金属镍的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c478d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0014-0,69) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,50) mg w próbce"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014-0,69) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,50) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nfrakcja wdychalna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","norm_bases":["PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nfrakcja wdychalna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc zwiazkow niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w probce\nfrakcja wdychalna\nZakres (0,0014-0,69) mg/m3\nZakres (0,0010 – 0,50) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of nickel compounds – calculated as Ni","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0014-0,69) mg/m3"},{"name":"Range","range":"(0,0010 – 0,50) mg w próbce"},{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014-0,69) mg/m3"},{"name":"Range","range":"(0,0010 – 0,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of nickel compounds – calculated as Ni Flame atomic absorption spectrometry (FAAS) respirable fraction Range Range inhalable fraction Range Range PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0014-0,69) mg/m3"},{"name":"范围","range":"(0,0010 – 0,50) mg w próbce"},{"name":"可吸入组分"},{"name":"范围","range":"(0,0014-0,69) mg/m3"},{"name":"范围","range":"(0,0010 – 0,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 呼吸性组分 范围 范围 可吸入组分 范围 范围 PN-Z-04502:2019-10 EV-IR-72 wyd. 1 z 03.01.2025","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c478e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość ołowiu i jego związków nieorganicznych przeliczeniu na Pb – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0021 – 0,111) mg/m3"},{"name":"Zakres","range":"(0,00150 – 0,080) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość ołowiu i jego związków nieorganicznych przeliczeniu na Pb – frakcja wdychalna\nZakres:\nZakres (0,0021 – 0,111) mg/m3\nZakres (0,00150 – 0,080) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość ołowiu i jego związków nieorganicznych przeliczeniu na Pb – frakcja wdychalna\nZakres:\nZakres (0,0021 – 0,111) mg/m3\nZakres (0,00150 – 0,080) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc olowiu i jego zwiazkow nieorganicznych przeliczeniu na Pb – frakcja wdychalna\nZakres:\nZakres (0,0021 – 0,111) mg/m3\nZakres (0,00150 – 0,080) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0021 – 0,111) mg/m3"},{"name":"Range","range":"(0,00150 – 0,080) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04487:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0021 – 0,111) mg/m3"},{"name":"范围","range":"(0,00150 – 0,080) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c478f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu – w przeliczeniu na Sb","parameters":[{"name":"Zakres","range":"(0,028 – 1,38) mg/m3"},{"name":"Zakres","range":"(0,020 – 1,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu – w przeliczeniu na Sb\nZakres:\nZakres (0,028 – 1,38) mg/m3\nZakres (0,020 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04146-3:2006","norm_bases":["PN-Z-04146-3:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu – w przeliczeniu na Sb\nZakres:\nZakres (0,028 – 1,38) mg/m3\nZakres (0,020 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04146-3:2006 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc antymonu i jego zwiazkow nieorganicznych, z wyjatkiem stibanu – w przeliczeniu na Sb\nZakres:\nZakres (0,028 – 1,38) mg/m3\nZakres (0,020 – 1,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04146-3:2006","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of antimony and its inorganic compounds, except stibine – calculated as Sb","parameters_en":[{"name":"Range","range":"(0,028 – 1,38) mg/m3"},{"name":"Range","range":"(0,020 – 1,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of antimony and its inorganic compounds, except stibine – calculated as Sb Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04146-3:2006","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,028 – 1,38) mg/m3"},{"name":"范围","range":"(0,020 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04146-3:2006","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4790","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0017 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,001250 – 10,4) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,0017 – 25,0) mg/m3\nZakres (0,001250 – 10,4) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-87/Z-04100.03","norm_bases":["PN-87/Z-04100.03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,0017 – 25,0) mg/m3\nZakres (0,001250 – 10,4) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,0017 – 25,0) mg/m3\nZakres (0,001250 – 10,4) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03","categories":["environment"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of zinc oxide – calculated as Zn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0017 – 25,0) mg/m3"},{"name":"Range","range":"(0,001250 – 10,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of zinc oxide – calculated as Zn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-87/Z-04100.03","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0017 – 25,0) mg/m3"},{"name":"范围","range":"(0,001250 – 10,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-87/Z-04100.03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4791","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,012 – 2,5) mg/m3"},{"name":"Zakres","range":"(0,0087 – 1,740) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,5) mg/m3\nZakres (0,0087 – 1,740) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,5) mg/m3\nZakres (0,0087 – 1,740) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,5) mg/m3\nZakres (0,0087 – 1,740) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,012 – 2,5) mg/m3"},{"name":"Range","range":"(0,0087 – 1,740) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Sodium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04435:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,012 – 2,5) mg/m3"},{"name":"范围","range":"(0,0087 – 1,740) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 氢氧化钠的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04435:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"氢氧化钠的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4792","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,010 – 2,5) mg/m3"},{"name":"Zakres","range":"(0,00720 – 1,20) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,010 – 2,5) mg/m3\nZakres (0,00720 – 1,20) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,010 – 2,5) mg/m3\nZakres (0,00720 – 1,20) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc wodorotlenku potasu\nZakres:\nZakres (0,010 – 2,5) mg/m3\nZakres (0,00720 – 1,20) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011","categories":["environment"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,010 – 2,5) mg/m3"},{"name":"Range","range":"(0,00720 – 1,20) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Potassium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04436:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,010 – 2,5) mg/m3"},{"name":"范围","range":"(0,00720 – 1,20) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 氢氧化钾的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04436:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"氢氧化钾的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4793","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenku wapnia","parameters":[{"name":"frakcja wdychalna:"},{"name":"Zakres","range":"(0,10 – 15,0) mg/m3"},{"name":"Zakres","range":"(0,07 – 4,60) mg w próbce"},{"name":"frakcja respirabilna:"},{"name":"Zakres","range":"(0,09 – 15,0) mg/m3"},{"name":"Zakres","range":"(0,07 – 4,60) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,10 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w próbce\nfrakcja respirabilna:\nZakres (0,09 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04442:2023-10","norm_bases":["PN-Z-04442:2023-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,10 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w próbce\nfrakcja respirabilna:\nZakres (0,09 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04442:2023-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc tlenku wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,10 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w probce\nfrakcja respirabilna:\nZakres (0,09 – 15,0) mg/m3\nZakres (0,07 – 4,60) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04442:2023-10","categories":["environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium oxide concentration/content","parameters_en":[{"name":"inhalable fraction:"},{"name":"Range","range":"(0,10 – 15,0) mg/m3"},{"name":"Range","range":"(0,07 – 4,60) mg w próbce"},{"name":"frakcja respirabilna:"},{"name":"Range","range":"(0,09 – 15,0) mg/m3"},{"name":"Range","range":"(0,07 – 4,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Calcium oxide concentration/content Flame atomic absorption spectrometry (FAAS) inhalable fraction: Range Range Range Range PN-Z-04442:2023-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"frakcja wdychalna:"},{"name":"范围","range":"(0,10 – 15,0) mg/m3"},{"name":"范围","range":"(0,07 – 4,60) mg w próbce"},{"name":"frakcja respirabilna:"},{"name":"范围","range":"(0,09 – 15,0) mg/m3"},{"name":"范围","range":"(0,07 – 4,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 氧化钙的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 范围 范围 PN-Z-04442:2023-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"氧化钙的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4794","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość węglanu wapnia","parameters":[{"name":"frakcja wdychalna:"},{"name":"Zakres","range":"(0,22 – 25,8) mg/m3"},{"name":"Zakres","range":"(0,160 – 18,60) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,22 – 25,8) mg/m3\nZakres (0,160 – 18,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04294:2001","norm_bases":["PN-Z-04294:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,22 – 25,8) mg/m3\nZakres (0,160 – 18,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04294:2001 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc weglanu wapnia\nZakres:\nfrakcja wdychalna:\nZakres (0,22 – 25,8) mg/m3\nZakres (0,160 – 18,60) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04294:2001","categories":["environment"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of calcium carbonate","parameters_en":[{"name":"inhalable fraction:"},{"name":"Range","range":"(0,22 – 25,8) mg/m3"},{"name":"Range","range":"(0,160 – 18,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of calcium carbonate Flame atomic absorption spectrometry (FAAS) inhalable fraction: Range Range PN-Z-04294:2001","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"frakcja wdychalna:"},{"name":"范围","range":"(0,22 – 25,8) mg/m3"},{"name":"范围","range":"(0,160 – 18,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04294:2001","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4795","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenku magnezu","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,47 – 22,7) mg/m3"},{"name":"Zakres","range":"(0,340 – 16,4) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku magnezu\nZakres:\nfrakcja wdychalna\nZakres (0,47 – 22,7) mg/m3\nZakres (0,340 – 16,4) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04470:2015-10","norm_bases":["PN-Z-04470:2015-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość tlenku magnezu\nZakres:\nfrakcja wdychalna\nZakres (0,47 – 22,7) mg/m3\nZakres (0,340 – 16,4) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04470:2015-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc tlenku magnezu\nZakres:\nfrakcja wdychalna\nZakres (0,47 – 22,7) mg/m3\nZakres (0,340 – 16,4) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04470:2015-10","categories":["environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium oxide concentration/content","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,47 – 22,7) mg/m3"},{"name":"Range","range":"(0,340 – 16,4) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Magnesium oxide concentration/content Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-Z-04470:2015-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,47 – 22,7) mg/m3"},{"name":"范围","range":"(0,340 – 16,4) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-Z-04470:2015-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4796","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,174 – 4,16) mg/m3"},{"name":"Zakres","range":"(0,1250 – 3,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,174 – 4,16) mg/m3\nZakres (0,1250 – 3,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04488:2017-10","norm_bases":["PN-Z-04488:2017-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,174 – 4,16) mg/m3\nZakres (0,1250 – 3,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc cyny i jej zwiazkow nieorganicznych, z wyjatkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,174 – 4,16) mg/m3\nZakres (0,1250 – 3,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10","categories":["environment"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,174 – 4,16) mg/m3"},{"name":"Range","range":"(0,1250 – 3,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-Z-04488:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,174 – 4,16) mg/m3"},{"name":"范围","range":"(0,1250 – 3,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-Z-04488:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4797","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość selenu i jego związków, z wyjątkiem selanu – w przeliczeniu na Se","parameters":[{"name":"Zakres","range":"(0,0069 – 0,70) mg/m3"},{"name":"Zakres","range":"(0,0050 – 0,40) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość selenu i jego związków, z wyjątkiem selanu – w przeliczeniu na Se\nZakres:\nZakres (0,0069 – 0,70) mg/m3\nZakres (0,0050 – 0,40) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04468:2015-10","norm_bases":["PN-Z-04468:2015-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość selenu i jego związków, z wyjątkiem selanu – w przeliczeniu na Se\nZakres:\nZakres (0,0069 – 0,70) mg/m3\nZakres (0,0050 – 0,40) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04468:2015-10 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc selenu i jego zwiazkow, z wyjatkiem selanu – w przeliczeniu na Se\nZakres:\nZakres (0,0069 – 0,70) mg/m3\nZakres (0,0050 – 0,40) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04468:2015-10","categories":["environment"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of selenium and its compounds, except selane – calculated as Se","parameters_en":[{"name":"Range","range":"(0,0069 – 0,70) mg/m3"},{"name":"Range","range":"(0,0050 – 0,40) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of selenium and its compounds, except selane – calculated as Se Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04468:2015-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0069 – 0,70) mg/m3"},{"name":"范围","range":"(0,0050 – 0,40) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04468:2015-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c4798","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,0014 – 0,069) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,050) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,0014 – 0,069) mg/m3\nZakres (0,0010 – 0,050) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04291:2003","norm_bases":["PN-Z-04291:2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,0014 – 0,069) mg/m3\nZakres (0,0010 – 0,050) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc kobaltu i jego zwiazkow nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,0014 – 0,069) mg/m3\nZakres (0,0010 – 0,050) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cobalt and its inorganic compounds – calculated as Co","parameters_en":[{"name":"Range","range":"(0,0014 – 0,069) mg/m3"},{"name":"Range","range":"(0,0010 – 0,050) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of cobalt and its inorganic compounds – calculated as Co Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04291:2003","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0014 – 0,069) mg/m3"},{"name":"范围","range":"(0,0010 – 0,050) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 钴及其无机化合物的浓度/含量 － 以 Co 计 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04291:2003","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"钴及其无机化合物的浓度/含量 － 以 Co 计"},{"_id":"6a82eafc884ede9a1b2c4799","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,010 – 1,38) mg/m3"},{"name":"Zakres","range":"(0,0075 – 1,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,010 – 1,38) mg/m3\nZakres (0,0075 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04434:2011","norm_bases":["PN-Z-04434:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,010 – 1,38) mg/m3\nZakres (0,0075 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc chromu metalicznego, zwiazkow chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,010 – 1,38) mg/m3\nZakres (0,0075 – 1,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011","categories":["materials","environment"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 1,38) mg/m3"},{"name":"Range","range":"(0,0075 – 1,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04434:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,010 – 1,38) mg/m3"},{"name":"范围","range":"(0,0075 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04434:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c479a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chromu metalicznego, związki chromu (II) - w przeliczeniu na Cr (II), związki chromu (III) – w przeliczeniu na Cr (III)","parameters":[],"technique":"Metoda z obliczeń","techniques":["Metoda z obliczeń"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związki chromu (II) - w przeliczeniu na Cr (II), związki chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń","reference":"EV-PB-17, wydanie 1 z 18.12.2023","norm_bases":["EV-PB-17, wydanie 1 z 18.12.2023"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość chromu metalicznego, związki chromu (II) - w przeliczeniu na Cr (II), związki chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń EV-PB-17, wydanie 1 z 18.12.2023 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc chromu metalicznego, zwiazki chromu (II) - w przeliczeniu na Cr (II), zwiazki chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczen EV-PB-17, wydanie 1 z 18.12.2023","categories":["materials","environment"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment − air − air samples collected on filters Calculation method EV-PB-17, wydanie 1 z 18.12.2023","technique_en":"Calculation method","test_object_en":"Workplace environment − air − air samples collected on filters","search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 计算法 EV-PB-17, wydanie 1 z 18.12.2023","technique_zh":"计算法","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c479b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,0014 - 1,38) mg/m3"},{"name":"Zakres","range":"(0,0010 – 1,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,0014 - 1,38) mg/m3\nZakres (0,0010 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","norm_bases":["PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,0014 - 1,38) mg/m3\nZakres (0,0010 – 1,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc miedzi i jej zwiazkow nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,0014 - 1,38) mg/m3\nZakres (0,0010 – 1,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","categories":["environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of copper and its inorganic compounds – calculated as Cu","parameters_en":[{"name":"Range","range":"(0,0014 - 1,38) mg/m3"},{"name":"Range","range":"(0,0010 – 1,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of copper and its inorganic compounds – calculated as Cu Flame atomic absorption spectrometry (FAAS) Range Range PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0014 - 1,38) mg/m3"},{"name":"范围","range":"(0,0010 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 铜及其无机化合物的浓度/含量 － 以 Cu 计 火焰原子吸收光谱法（FAAS） 范围 范围 PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"铜及其无机化合物的浓度/含量 － 以 Cu 计"},{"_id":"6a82eafc884ede9a1b2c479c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0028 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,0020 – 10,0) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0025 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,0020 – 10,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0028 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w próbce\nfrakcja respirabilna\nZakres (0,0025 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","norm_bases":["PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0028 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w próbce\nfrakcja respirabilna\nZakres (0,0025 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc tlenkow zelaza – w przeliczeniu na Fe tlenek zelaza (III), tlenek zelaza (II), tetratlenek trizelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0028 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w probce\nfrakcja respirabilna\nZakres (0,0025 – 25,0) mg/m3\nZakres (0,0020 – 10,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","categories":["environment"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0028 – 25,0) mg/m3"},{"name":"Range","range":"(0,0020 – 10,0) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0025 – 25,0) mg/m3"},{"name":"Range","range":"(0,0020 – 10,0) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0028 – 25,0) mg/m3"},{"name":"范围","range":"(0,0020 – 10,0) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0025 – 25,0) mg/m3"},{"name":"范围","range":"(0,0020 – 10,0) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c479d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014 – 0,80) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,60) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0013–0,75) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,60) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nfrakcja respirabilna\nZakres (0,0013–0,75) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","norm_bases":["PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nfrakcja respirabilna\nZakres (0,0013–0,75) mg/m3\nZakres (0,0010 – 0,60) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 0,80) mg/m3\nZakres (0,0010 – 0,60) mg w probce\nfrakcja respirabilna\nZakres (0,0013–0,75) mg/m3\nZakres (0,0010 – 0,60) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","categories":["environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of manganese and its inorganic compounds – expressed as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014 – 0,80) mg/m3"},{"name":"Range","range":"(0,0010 – 0,60) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0013–0,75) mg/m3"},{"name":"Range","range":"(0,0010 – 0,60) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of manganese and its inorganic compounds – expressed as Mn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0014 – 0,80) mg/m3"},{"name":"范围","range":"(0,0010 – 0,60) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0013–0,75) mg/m3"},{"name":"范围","range":"(0,0010 – 0,60) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 锰及其无机化合物的浓度/含量 － 以 Mn 计 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-79/Z-04106.02 EV-IR-68 wydanie 1 z 18.12.2023 pkt. 5.1","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"锰及其无机化合物的浓度/含量 － 以 Mn 计"},{"_id":"6a82eafc884ede9a1b2c479e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,0083 – 1,11) mg/m3"},{"name":"Zakres","range":"(0,0060 – 0,80) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,0083 – 1,11) mg/m3\nZakres (0,0060 – 0,80) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-02:1979","norm_bases":["PN-Z-04106-02:1979"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,0083 – 1,11) mg/m3\nZakres (0,0060 – 0,80) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc chromu metalicznego, zwiazkow chromu: (chrom (II), chrom (III), chrom (VI)) – w przeliczeniu na Cr\nZakres:\nZakres (0,0083 – 1,11) mg/m3\nZakres (0,0060 – 0,80) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979","categories":["materials","environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0083 – 1,11) mg/m3"},{"name":"Range","range":"(0,0060 – 0,80) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04106-02:1979","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0083 – 1,11) mg/m3"},{"name":"范围","range":"(0,0060 – 0,80) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04106-02:1979","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c479f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,0014 – 0,69) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,50) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","norm_bases":["PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc niklu metalicznego\nZakres:\nZakres (0,0014 – 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","categories":["materials","environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic nickel concentration/content","parameters_en":[{"name":"Range","range":"(0,0014 – 0,69) mg/m3"},{"name":"Range","range":"(0,0010 – 0,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Metallic nickel concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0014 – 0,69) mg/m3"},{"name":"范围","range":"(0,0010 – 0,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 金属镍的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品","methodology_zh":"金属镍的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47a0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0009 - 0,47) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,50) mg w próbce"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014 - 0,69) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,50) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0009 - 0,47) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nfrakcja wdychalna\nZakres (0,0014 - 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","norm_bases":["PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze − próbki powietrza pobrane na filtry Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0009 - 0,47) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nfrakcja wdychalna\nZakres (0,0014 - 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025 Srodowisko pracy − powietrze − probki powietrza pobrane na filtry Stezenie/zawartosc zwiazkow niklu – w przeliczeniu na Ni\nZakres:\nfrakcja respirabilna\nZakres (0,0009 - 0,47) mg/m3\nZakres (0,0010 – 0,50) mg w probce\nfrakcja wdychalna\nZakres (0,0014 - 0,69) mg/m3\nZakres (0,0010 – 0,50) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","categories":["environment"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of nickel compounds – calculated as Ni","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0009 - 0,47) mg/m3"},{"name":"Range","range":"(0,0010 – 0,50) mg w próbce"},{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014 - 0,69) mg/m3"},{"name":"Range","range":"(0,0010 – 0,50) mg w próbce"}],"search_en":"Workplace environment − air − air samples collected on filters Concentration/content of nickel compounds – calculated as Ni Flame atomic absorption spectrometry (FAAS) respirable fraction Range Range inhalable fraction Range Range PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air − air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0009 - 0,47) mg/m3"},{"name":"范围","range":"(0,0010 – 0,50) mg w próbce"},{"name":"可吸入组分"},{"name":"范围","range":"(0,0014 - 0,69) mg/m3"},{"name":"范围","range":"(0,0010 – 0,50) mg w próbce"}],"search_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 呼吸性组分 范围 范围 可吸入组分 范围 范围 PN-Z-04106-02:1979 EV-IR-72 wyd. 1 z 03.01.2025","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 − 空气 − 用滤膜采集的空气样品"},{"_id":"6a82eafc884ede9a1b2c47a1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a82eafc884ede9a1b2c47a2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla prędkości","parameters":[{"name":"Zakres","range":"(0,6 – 40) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"computed":[],"activity":"Strumień objętości gazu dla prędkości\nZakres (0,6 – 40) m/s\nMetoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla prędkości\nZakres (0,6 – 40) m/s\nMetoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla predkosci\nZakres (0,6 – 40) m/s\nMetoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for velocity","parameters_en":[{"name":"Range","range":"(0,6 – 40) m/s"}],"search_en":"Waste gases Gas volume flow rate for velocity Anemometric method Range PN-Z-04030-7:1994","technique_en":"Anemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,6 – 40) m/s"}],"search_zh":"废气 风速仪法 范围 PN-Z-04030-7:1994","test_object_zh":"废气","technique_zh":"风速仪法"},{"_id":"6a82eafc884ede9a1b2c47a3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c47a4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 21,9) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 21,9) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 21,9) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 21,9) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 21,9) g/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 21,9) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47a5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c47a6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(2,9 – 22,5) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"computed":[],"activity":"Stężenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD) PN-ISO 10396:2001","categories":["other"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(2,9 – 22,5) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Range PN-ISO 10396:2001","technique_en":"Paramagnetic method (PMD)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,9 – 22,5) %"}],"search_zh":"废气 氧浓度 顺磁法（PMD） 范围 PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法（PMD）"},{"_id":"6a82eafc884ede9a1b2c47a7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO, CO2","parameters":[{"name":"CO","range":"(1,25 – 5467) mg/m3"},{"name":"CO2","range":"(0,2 – 27,5) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO, CO2\nZakres:\nCO (1,25 – 5467) mg/m3\nCO2 (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie CO, CO2\nZakres:\nCO (1,25 – 5467) mg/m3\nCO2 (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie CO, CO2\nZakres:\nCO (1,25 – 5467) mg/m3\nCO2 (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO, CO2 concentration","parameters_en":[{"name":"CO","range":"(1,25 – 5467) mg/m3"},{"name":"CO2","range":"(0,2 – 27,5) %"}],"search_en":"Waste gases CO, CO2 concentration Non-dispersive infrared spectrometry (NDIR) CO CO2 PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 非分散红外光谱法（NDIR） CO CO2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"CO","range":"(1,25 – 5467) mg/m3"},{"name":"CO2","range":"(0,2 – 27,5) %"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a82eafc884ede9a1b2c47a8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO, CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja CO, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47a9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NO, NOx","parameters":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-ISO 10396:2001 Gazy odlotowe Stezenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-ISO 10396:2001","categories":["other"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx concentration","parameters_en":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"search_en":"Waste gases NO, NOx concentration Chemiluminescence method (CLD) NO NOx PN-ISO 10396:2001","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","search_zh":"废气 NO、NOx 浓度 化学发光法（CLD） NO NOx PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"technique_zh":"化学发光法（CLD）","methodology_zh":"NO、NOx 浓度"},{"_id":"6a82eafc884ede9a1b2c47aa","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47ab","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(2,9 – 5358) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie SO2\nZakres (2,9 – 5358) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (2,9 – 5358) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie SO2\nZakres (2,9 – 5358) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(2,9 – 5358) mg/m3"}],"search_en":"Waste gases SO2 concentration Non-dispersive infrared spectrometry (NDIR) Range PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,9 – 5358) mg/m3"}],"search_zh":"废气 SO2 浓度 非分散红外光谱法（NDIR） 范围 PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"SO2 浓度"},{"_id":"6a82eafc884ede9a1b2c47ac","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 emission (calculated)","search_en":"Waste gases SO2 emission (calculated) PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 SO2 排放量（计算值） PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c47ad","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢浓度测定采样 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c47ae","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,130 – 231) mg/m3"},{"name":"Zakres","range":"(0,026 – 23,1) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,130 – 231) mg/m3\nZakres (0,026 – 23,1) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,130 – 231) mg/m3\nZakres (0,026 – 23,1) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,130 – 231) mg/m3\nZakres (0,026 – 23,1) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,130 – 231) mg/m3"},{"name":"Range","range":"(0,026 – 23,1) mg w próbce"}],"search_en":"Waste gases Hydrogen chloride concentration/content Spectrophotometric method Range Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,130 – 231) mg/m3"},{"name":"范围","range":"(0,026 – 23,1) mg w próbce"}],"search_zh":"废气 氯化氢的浓度/含量 分光光度法 范围 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47af","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HCl emission (calculated)","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c47b0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 氟化氢浓度测定采样 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c47b1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HF emission (calculated)","search_en":"Waste gases HF emission (calculated) ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c47b2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","categories":["materials"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V PN-EN 14385:2005","test_object_zh":"废气","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V"},{"_id":"6a82eafc884ede9a1b2c47b3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień różnicowych > 5 Pa","parameters":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017 Gazy odlotowe Strumien objetosci gazu dla cisnien roznicowych > 5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","categories":["other"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for differential pressures > 5 Pa","search_en":"Waste gases Gas volume flow rate for differential pressures > 5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","technique_en":"Differential pressure measurement method","test_object_en":"Waste gases","search_zh":"废气 差压测量法 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","test_object_zh":"废气","technique_zh":"差压测量法"},{"_id":"6a82eafc884ede9a1b2c47b4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(29 – 250) g/m3"},{"name":"Zakres","range":"(4,0 – 40,0) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (29 – 250) g/m3\nZakres (4,0 – 40,0) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (29 – 250) g/m3\nZakres (4,0 – 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (29 – 250) g/m3\nZakres (4,0 – 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(29 – 250) g/m3"},{"name":"Range","range":"(4,0 – 40,0) %"}],"search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Range Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(29 – 250) g/m3"},{"name":"范围","range":"(4,0 – 40,0) %"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 范围 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a82eafc884ede9a1b2c47b5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(2,9 – 22,5) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"computed":[],"activity":"Stężenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (2,9 – 22,5) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(2,9 – 22,5) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method (PMD)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,9 – 22,5) %"}],"search_zh":"废气 氧浓度 顺磁法（PMD） 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法（PMD）"},{"_id":"6a82eafc884ede9a1b2c47b6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,2 – 27,5) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO2\nZakres (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie CO2\nZakres (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie CO2\nZakres (0,2 – 27,5) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,2 – 27,5) %"}],"search_en":"Waste gases CO2 concentration Non-dispersive infrared spectrometry (NDIR) Range ISO 12039:2019","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,2 – 27,5) %"}],"search_zh":"废气 CO2 浓度 非分散红外光谱法（NDIR） 范围 ISO 12039:2019","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a82eafc884ede9a1b2c47b7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 emission (calculated)","search_en":"Waste gases CO2 emission (calculated) ISO 12039:2019","test_object_en":"Waste gases","search_zh":"废气 CO2 排放（由计算得出） ISO 12039:2019","test_object_zh":"废气","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c47b8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(1,25 – 5467) mg/m3"}],"technique":"Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO\nZakres (1,25 – 5467) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie CO\nZakres (1,25 – 5467) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie CO\nZakres (1,25 – 5467) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(1,25 – 5467) mg/m3"}],"search_en":"Waste gases CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,25 – 5467) mg/m3"}],"search_zh":"废气 CO 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 浓度","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a82eafc884ede9a1b2c47b9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO emission (calculated)","search_en":"Waste gases CO emission (calculated) PN-EN 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 CO 排放量（计算值） PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c47ba","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NO, NOx","parameters":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie NO, NOx\nZakres:\nNO (1,4 – 3347) mg/m3\nNOx (2,1 – 5125) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx concentration","parameters_en":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"search_en":"Waste gases NO, NOx concentration Chemiluminescence method (CLD) NO NOx PN-EN 14792:2017-04","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","search_zh":"废气 NO、NOx 浓度 化学发光法（CLD） NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(1,4 – 3347) mg/m3"},{"name":"NOx","range":"(2,1 – 5125) mg/m3"}],"technique_zh":"化学发光法（CLD）","methodology_zh":"NO、NOx 浓度"},{"_id":"6a82eafc884ede9a1b2c47bb","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NOx w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47bc","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia dwutlenku siarki PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia dwutlenku siarki PN-EN 14791:2017-04","categories":["other"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of sulfur dioxide concentration","search_en":"Waste gases Sampling for the determination of sulfur dioxide concentration PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 用于测定二氧化硫浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定二氧化硫浓度的采样"},{"_id":"6a82eafc884ede9a1b2c47bd","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku siarki (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja dwutlenku siarki (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide emission (calculated)","search_en":"Waste gases Sulphur dioxide emission (calculated) PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 二氧化硫排放（由计算得出） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c47be","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metali","parameters":[{"name":"Cd","range":"(0,0010 – 20) mg/m3"},{"name":"Zakres","range":"(0,00010 – 10) mg w próbce"},{"name":"Cr","range":"(0,00150 – 20) mg/m3"},{"name":"(0,0150 – 10) mg w próbce Co","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Cu","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Mn","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Ni","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Pb","range":"(0,000750 - 20) mg/m3"},{"name":"(0,00750 – 10) mg w próbce Sb","range":"(0,010 – 20) mg/m3"},{"name":"(0,10 – 10) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość metali\nZakres:\nCd (0,0010 – 20) mg/m3\nZakres (0,00010 – 10) mg w próbce\nCr (0,00150 – 20) mg/m3\n(0,0150 – 10) mg w próbce Co (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Cu (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w próbce Mn (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w próbce Ni (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Pb (0,000750 - 20) mg/m3\n(0,00750 – 10) mg w próbce Sb (0,010 – 20) mg/m3\n(0,10 – 10) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metali\nZakres:\nCd (0,0010 – 20) mg/m3\nZakres (0,00010 – 10) mg w próbce\nCr (0,00150 – 20) mg/m3\n(0,0150 – 10) mg w próbce Co (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Cu (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w próbce Mn (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w próbce Ni (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Pb (0,000750 - 20) mg/m3\n(0,00750 – 10) mg w próbce Sb (0,010 – 20) mg/m3\n(0,10 – 10) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14385:2005 Gazy odlotowe Stezenie/zawartosc metali\nZakres:\nCd (0,0010 – 20) mg/m3\nZakres (0,00010 – 10) mg w probce\nCr (0,00150 – 20) mg/m3\n(0,0150 – 10) mg w probce Co (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w probce Cu (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w probce Mn (0,000250 – 20) mg/m3\n(0,00250 – 10) mg w probce Ni (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w probce Pb (0,000750 - 20) mg/m3\n(0,00750 – 10) mg w probce Sb (0,010 – 20) mg/m3\n(0,10 – 10) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14385:2005","categories":["materials"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Cd","range":"(0,0010 – 20) mg/m3"},{"name":"Range","range":"(0,00010 – 10) mg w próbce"},{"name":"Cr","range":"(0,00150 – 20) mg/m3"},{"name":"(0,0150 – 10) mg w próbce Co","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Cu","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Mn","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Ni","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Pb","range":"(0,000750 - 20) mg/m3"},{"name":"(0,00750 – 10) mg w próbce Sb","range":"(0,010 – 20) mg/m3"},{"name":"(0,10 – 10) mg w próbce"}],"search_en":"Waste gases Flame atomic absorption spectrometry (FAAS) Cd Range Cr PN-EN 14385:2005","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Waste gases","parameters_zh":[{"name":"Cd","range":"(0,0010 – 20) mg/m3"},{"name":"范围","range":"(0,00010 – 10) mg w próbce"},{"name":"Cr","range":"(0,00150 – 20) mg/m3"},{"name":"(0,0150 – 10) mg w próbce Co","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Cu","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Mn","range":"(0,000250 – 20) mg/m3"},{"name":"(0,00250 – 10) mg w próbce Ni","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Pb","range":"(0,000750 - 20) mg/m3"},{"name":"(0,00750 – 10) mg w próbce Sb","range":"(0,010 – 20) mg/m3"},{"name":"(0,10 – 10) mg w próbce"}],"search_zh":"废气 火焰原子吸收光谱法（FAAS） Cd 范围 Cr PN-EN 14385:2005","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47bf","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） PN-EN 14385:2005","test_object_zh":"废气","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c47c0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of total mercury concentration","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c47c1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","search_en":"Waste gases Total mercury emission (calculated) PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c47c2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c47c3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość acetonu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość acetonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc acetonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetone concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Acetone concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 丙酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丙酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47c4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość ksylenu – mieszanina izomerów:","parameters":[{"name":"m-ksylen"},{"name":"Zakres","range":"(0,017 - 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"o-ksylen"},{"name":"Zakres","range":"(0,017 - 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"p-ksylen"},{"name":"Zakres","range":"(0,0170 - 2667) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość ksylenu – mieszanina izomerów:\nZakres:\nm-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\no-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\np-ksylen\nZakres (0,0170 - 2667) mg/m3\nZakres (0,001 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość ksylenu – mieszanina izomerów:\nZakres:\nm-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\no-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\np-ksylen\nZakres (0,0170 - 2667) mg/m3\nZakres (0,001 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc ksylenu – mieszanina izomerow:\nZakres:\nm-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\no-ksylen\nZakres (0,017 - 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\np-ksylen\nZakres (0,0170 - 2667) mg/m3\nZakres (0,001 – 4,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"m-xylene"},{"name":"Range","range":"(0,017 - 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"o-xylene"},{"name":"Range","range":"(0,017 - 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"p-xylene"},{"name":"Range","range":"(0,0170 - 2667) mg/m3"},{"name":"Range","range":"(0,001 – 4,0) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) m-xylene Range Range o-xylene Range Range p-xylene Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"间二甲苯"},{"name":"范围","range":"(0,017 - 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"邻二甲苯"},{"name":"范围","range":"(0,017 - 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"p-ksylen"},{"name":"范围","range":"(0,0170 - 2667) mg/m3"},{"name":"范围","range":"(0,001 – 4,0) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 间二甲苯 范围 范围 邻二甲苯 范围 范围 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47c5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Suma stężenia/zawartości ksylenu – mieszanina izomerów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości ksylenu – mieszanina izomerów (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Suma stężenia/zawartości ksylenu – mieszanina izomerów (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Suma stezenia/zawartosci ksylenu – mieszanina izomerow (z obliczen) PN-EN 13649:2005","categories":["other"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of xylene concentration/content – mixture of isomers (calculated)","search_en":"Waste gases Sum of xylene concentration/content – mixture of isomers (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47c6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość etanolu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość etanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc etanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethanol concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Ethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47c7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość butan-1-olu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość butan-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc butan-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Butan-1-ol concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Butan-1-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 正丁醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"正丁醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47c8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-metylopropanu-1-olu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-metylopropanu-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-metylopropanu-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-metylopropanu-1-olu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47c9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu etylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu etylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu etylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Ethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 乙酸乙酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙酸乙酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47ca","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octan n-butylu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octan n-butylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octan n-butylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octan n-butylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47cb","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość toluenu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość toluenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość toluenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc toluenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Toluene concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Toluene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 甲苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47cc","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-butoksyetanolu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-butoksyetanolu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-butoxyethanol concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases 2-butoxyethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 2-丁氧基乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"2-丁氧基乙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47cd","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,017– 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość benzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc benzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration/content","parameters_en":[{"name":"Range","range":"(0,017– 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Benzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017– 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47ce","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość styrenu","parameters":[{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość styrenu\nZakres:\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość styrenu\nZakres:\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc styrenu\nZakres:\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene concentration/content","parameters_en":[{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Styrene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47cf","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metakrylanu metylu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc metakrylanu metylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl methacrylate concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,5) mg w próbce"}],"search_en":"Waste gases Methyl methacrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,5) mg w próbce"}],"search_zh":"废气 甲基丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲基丙烯酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(0,017– 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc etylobenzenu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylbenzene concentration/content","parameters_en":[{"name":"Range","range":"(0,017– 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Ethylbenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017– 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 乙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość cykloheksanonu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc cykloheksanonu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyclohexanone concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Cyclohexanone concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 环己酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"环己酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(0,017 – 2667) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość cykloheksanu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc cykloheksanu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyclohexane concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2667) mg/m3"},{"name":"Range","range":"(0,001 – 4,0) mg w próbce"}],"search_en":"Waste gases Cyclohexane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2667) mg/m3"},{"name":"范围","range":"(0,001 – 4,0) mg w próbce"}],"search_zh":"废气 环己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"环己烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu winylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu winylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu winylu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Vinyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 乙酸乙烯酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙酸乙烯酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość akrylonitrylu","parameters":[{"name":"Zakres","range":"(0,017 – 2667) mg/m3"},{"name":"Zakres","range":"(0,001 – 4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc akrylonitrylu\nZakres:\nZakres (0,017 – 2667) mg/m3\nZakres (0,001 – 4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylonitrile concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2667) mg/m3"},{"name":"Range","range":"(0,001 – 4) mg w próbce"}],"search_en":"Waste gases Acrylonitrile concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2667) mg/m3"},{"name":"范围","range":"(0,001 – 4) mg w próbce"}],"search_zh":"废气 丙烯腈的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丙烯腈的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość dichlorometanu","parameters":[{"name":"Zakres","range":"(0,017– 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość dichlorometanu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość dichlorometanu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc dichlorometanu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dichloromethane concentration/content","parameters_en":[{"name":"Range","range":"(0,017– 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Dichloromethane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017– 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 二氯甲烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"二氯甲烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47d6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość trimetylobenzenu – mieszanina izomerów","parameters":[{"name":"1, 2, 3 trimetylobenzen"},{"name":"Zakres","range":"(0,017– 2667) mg/m3"},{"name":"Zakres","range":"(0,001 – 4) mg w próbce"},{"name":"1, 2, 4 trimetylobenzen"},{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"1, 3, 5 trimetylobenzen"},{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość trimetylobenzenu – mieszanina izomerów\nZakres:\n1, 2, 3 trimetylobenzen\nZakres (0,017– 2667) mg/m3\nZakres (0,001 – 4) mg w próbce\n1, 2, 4 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n1, 3, 5 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość trimetylobenzenu – mieszanina izomerów\nZakres:\n1, 2, 3 trimetylobenzen\nZakres (0,017– 2667) mg/m3\nZakres (0,001 – 4) mg w próbce\n1, 2, 4 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n1, 3, 5 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc trimetylobenzenu – mieszanina izomerow\nZakres:\n1, 2, 3 trimetylobenzen\nZakres (0,017– 2667) mg/m3\nZakres (0,001 – 4) mg w probce\n1, 2, 4 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\n1, 3, 5 trimetylobenzen\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"1, 2, 3 trimetylobenzen"},{"name":"Range","range":"(0,017– 2667) mg/m3"},{"name":"Range","range":"(0,001 – 4) mg w próbce"},{"name":"1, 2, 4 trimetylobenzen"},{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"1, 3, 5 trimetylobenzen"},{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range Range Range Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"1, 2, 3 trimetylobenzen"},{"name":"范围","range":"(0,017– 2667) mg/m3"},{"name":"范围","range":"(0,001 – 4) mg w próbce"},{"name":"1, 2, 4 trimetylobenzen"},{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"1, 3, 5 trimetylobenzen"},{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47d7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Suma stężenia/zawartości trimetylobenzenu – mieszanina izomerów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości trimetylobenzenu – mieszanina izomerów (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Suma stężenia/zawartości trimetylobenzenu – mieszanina izomerów (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Suma stezenia/zawartosci trimetylobenzenu – mieszanina izomerow (z obliczen) PN-EN 13649:2005","categories":["other"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trimethylbenzene concentration/content – mixture of isomers (calculated)","search_en":"Waste gases Sum of trimethylbenzene concentration/content – mixture of isomers (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47d8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość tetrahydrofuranu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc tetrahydrofuranu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tetrahydrofuran","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Concentration/content of tetrahydrofuran Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47d9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość butan-2-olu","parameters":[{"name":"Zakres","range":"(0,017– 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-2-olu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość butan-2-olu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc butan-2-olu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butan-2-ol","parameters_en":[{"name":"Range","range":"(0,017– 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Concentration/content of butan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017– 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47da","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość propan-2-olu","parameters":[{"name":"Zakres","range":"(0,017 – 3067) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-2-olu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość propan-2-olu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc propan-2-olu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Propan-2-ol concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 3067) mg/m3"},{"name":"Range","range":"(0,001 – 4,6) mg w próbce"}],"search_en":"Waste gases Propan-2-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 3067) mg/m3"},{"name":"范围","range":"(0,001 – 4,6) mg w próbce"}],"search_zh":"废气 异丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"异丙醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47db","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,017 – 666) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,017 – 666) mg/m3\nZakres (0,001 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,017 – 666) mg/m3\nZakres (0,001 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (0,017 – 666) mg/m3\nZakres (0,001 – 1,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 666) mg/m3"},{"name":"Range","range":"(0,001 – 1,00) mg w próbce"}],"search_en":"Waste gases Acetic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 666) mg/m3"},{"name":"范围","range":"(0,001 – 1,00) mg w próbce"}],"search_zh":"废气 乙酸的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙酸的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47dc","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc tetrachloroetenu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrachloroethene concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Tetrachloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 四氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"四氯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47dd","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,020 – 400) mg/m3"},{"name":"Zakres","range":"(0,00118 – 0,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00118 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00118 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00118 – 0,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of buta-1,3-diene","parameters_en":[{"name":"Range","range":"(0,020 – 400) mg/m3"},{"name":"Range","range":"(0,00118 – 0,60) mg w próbce"}],"search_en":"Waste gases Concentration/content of buta-1,3-diene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,020 – 400) mg/m3"},{"name":"范围","range":"(0,00118 – 0,60) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47de","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chlorku winylu","parameters":[{"name":"Zakres","range":"(0,13 – 60,1) mg/m3"},{"name":"Zakres","range":"(0,004 – 0,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chlorku winylu\nZakres:\nZakres (0,13 – 60,1) mg/m3\nZakres (0,004 – 0,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chlorku winylu\nZakres:\nZakres (0,13 – 60,1) mg/m3\nZakres (0,004 – 0,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc chlorku winylu\nZakres:\nZakres (0,13 – 60,1) mg/m3\nZakres (0,004 – 0,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,13 – 60,1) mg/m3"},{"name":"Range","range":"(0,004 – 0,2) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,13 – 60,1) mg/m3"},{"name":"范围","range":"(0,004 – 0,2) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47df","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 1-metoksy-2-propanolu","parameters":[{"name":"Zakres","range":"(0,017– 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 1-metoksy-2-propanolu\nZakres:\nZakres (0,017– 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,017– 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017– 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość butan-2-onu","parameters":[{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-2-onu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość butan-2-onu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc butan-2-onu\nZakres:\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butan-2-one","parameters_en":[{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Concentration/content of butan-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 丁酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丁酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47e1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość węglowodorów alifatycznych:","parameters":[{"name":"pentan"},{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"heksan"},{"name":"Zakres","range":"(0,017 – 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"heptan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"oktan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"nonan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"dekan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"undekan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"dodekan"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość węglowodorów alifatycznych:\nZakres:\npentan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nheksan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nheptan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\noktan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nnonan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\ndekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nundekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\ndodekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość węglowodorów alifatycznych:\nZakres:\npentan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nheksan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nheptan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\noktan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nnonan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\ndekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nundekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\ndodekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc weglowodorow alifatycznych:\nZakres:\npentan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nheksan\nZakres (0,017 – 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nheptan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\noktan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nnonan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\ndekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nundekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\ndodekan\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"pentane"},{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"hexane"},{"name":"Range","range":"(0,017 – 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"heptane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"octane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"nonane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"decane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"undecane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"dodecane"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) pentane Range Range hexane Range Range heptane Range Range octane Range Range nonane Range Range decane Range Range undecane Range Range dodecane Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"戊烷"},{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"正己烷"},{"name":"范围","range":"(0,017 – 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"正庚烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"辛烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"壬烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"癸烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"十一烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"十二烷"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 戊烷 范围 范围 正己烷 范围 范围 正庚烷 范围 范围 辛烷 范围 范围 壬烷 范围 范围 癸烷 范围 范围 十一烷 范围 范围 十二烷 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Suma stężenia/zawartości węglowodorów alifatycznych C5-C12 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości węglowodorów alifatycznych C5-C12 (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Suma stężenia/zawartości węglowodorów alifatycznych C5-C12 (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Suma stezenia/zawartosci weglowodorow alifatycznych C5-C12 (z obliczen) PN-EN 13649:2005","categories":["other"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość etylotoluenu – mieszanina izomerów:","parameters":[{"name":"2-etylotoluen"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"3-etylotoluen"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"},{"name":"4-etylotoluen"},{"name":"Zakres","range":"(0,017- 2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etylotoluenu – mieszanina izomerów:\nZakres:\n2-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n3-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n4-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość etylotoluenu – mieszanina izomerów:\nZakres:\n2-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n3-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\n4-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc etylotoluenu – mieszanina izomerow:\nZakres:\n2-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\n3-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\n4-etylotoluen\nZakres (0,017- 2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"2-ethyltoluene"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"3-ethyltoluene"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"},{"name":"4-ethyltoluene"},{"name":"Range","range":"(0,017- 2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) 2-ethyltoluene Range Range 3-ethyltoluene Range Range 4-ethyltoluene Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"2-乙基甲苯"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"3-乙基甲苯"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"},{"name":"4-乙基甲苯"},{"name":"范围","range":"(0,017- 2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 2-乙基甲苯 范围 范围 3-乙基甲苯 范围 范围 4-乙基甲苯 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Suma stężenia/zawartości etylotoluenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości etylotoluenu (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Suma stężenia/zawartości etylotoluenu (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Suma stezenia/zawartosci etylotoluenu (z obliczen) PN-EN 13649:2005","categories":["other"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of ethyltoluene concentration/content (calculated)","search_en":"Waste gases Sum of ethyltoluene concentration/content (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Suma stężenia/zawartości węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężenia/zawartości węglowodorów aromatycznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Suma stężenia/zawartości węglowodorów aromatycznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Suma stezenia/zawartosci weglowodorow aromatycznych (z obliczen) PN-EN 13649:2005","categories":["other"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aromatic hydrocarbon concentration/content (calculated)","search_en":"Waste gases Sum of aromatic hydrocarbon concentration/content (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,017 – 3067) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość fenolu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc fenolu\nZakres:\nZakres (0,017 – 3067) mg/m3\nZakres (0,001 – 4,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 3067) mg/m3"},{"name":"Range","range":"(0,001 – 4,6) mg w próbce"}],"search_en":"Waste gases Phenol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 3067) mg/m3"},{"name":"范围","range":"(0,001 – 4,6) mg w próbce"}],"search_zh":"废气 苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47e7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość kumenu","parameters":[{"name":"Zakres","range":"(0,017 –2733) mg/m3"},{"name":"Zakres","range":"(0,001 – 4,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kumenu\nZakres:\nZakres (0,017 –2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość kumenu\nZakres:\nZakres (0,017 –2733) mg/m3\nZakres (0,001 – 4,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc kumenu\nZakres:\nZakres (0,017 –2733) mg/m3\nZakres (0,001 – 4,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cumene","parameters_en":[{"name":"Range","range":"(0,017 –2733) mg/m3"},{"name":"Range","range":"(0,001 – 4,1) mg w próbce"}],"search_en":"Waste gases Concentration/content of cumene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 –2733) mg/m3"},{"name":"范围","range":"(0,001 – 4,1) mg w próbce"}],"search_zh":"废气 异丙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"异丙苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47e8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-etoksyetanolu","parameters":[{"name":"Zakres","range":"(0,0150 – 606) mg/m3"},{"name":"Zakres","range":"(0,00090 – 0,91) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-etoksyetanolu\nZakres:\nZakres (0,0150 – 606) mg/m3\nZakres (0,00090 – 0,91) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-etoksyetanolu\nZakres:\nZakres (0,0150 – 606) mg/m3\nZakres (0,00090 – 0,91) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-etoksyetanolu\nZakres:\nZakres (0,0150 – 606) mg/m3\nZakres (0,00090 – 0,91) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-ethoxyethanol","parameters_en":[{"name":"Range","range":"(0,0150 – 606) mg/m3"},{"name":"Range","range":"(0,00090 – 0,91) mg w próbce"}],"search_en":"Waste gases Concentration/content of 2-ethoxyethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 606) mg/m3"},{"name":"范围","range":"(0,00090 – 0,91) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47e9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(0,0120 – 2000) mg/m3"},{"name":"Zakres","range":"(0,00070 – 3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 4-metylopentan-2-onu\nZakres:\nZakres (0,0120 – 2000) mg/m3\nZakres (0,00070 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 4-metylopentan-2-onu\nZakres:\nZakres (0,0120 – 2000) mg/m3\nZakres (0,00070 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 4-metylopentan-2-onu\nZakres:\nZakres (0,0120 – 2000) mg/m3\nZakres (0,00070 – 3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"4-methylpentan-2-one concentration/content","parameters_en":[{"name":"Range","range":"(0,0120 – 2000) mg/m3"},{"name":"Range","range":"(0,00070 – 3,0) mg w próbce"}],"search_en":"Waste gases 4-methylpentan-2-one concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0120 – 2000) mg/m3"},{"name":"范围","range":"(0,00070 – 3,0) mg w próbce"}],"search_zh":"废气 4-甲基-2-戊酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"4-甲基-2-戊酮的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47ea","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość akrylanu butylu","parameters":[{"name":"Zakres","range":"(0,020 – 1600) mg/m3"},{"name":"Zakres","range":"(0,00120 – 2,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylanu butylu\nZakres:\nZakres (0,020 – 1600) mg/m3\nZakres (0,00120 – 2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość akrylanu butylu\nZakres:\nZakres (0,020 – 1600) mg/m3\nZakres (0,00120 – 2,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc akrylanu butylu\nZakres:\nZakres (0,020 – 1600) mg/m3\nZakres (0,00120 – 2,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butyl acrylate","parameters_en":[{"name":"Range","range":"(0,020 – 1600) mg/m3"},{"name":"Range","range":"(0,00120 – 2,40) mg w próbce"}],"search_en":"Waste gases Concentration/content of butyl acrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,020 – 1600) mg/m3"},{"name":"范围","range":"(0,00120 – 2,40) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47eb","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość akrylanu metylu","parameters":[{"name":"Zakres","range":"(0,020 – 3266) mg/m3"},{"name":"Zakres","range":"(0,00120 – 4,90) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,020 – 3266) mg/m3\nZakres (0,00120 – 4,90) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,020 – 3266) mg/m3\nZakres (0,00120 – 4,90) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc akrylanu metylu\nZakres:\nZakres (0,020 – 3266) mg/m3\nZakres (0,00120 – 4,90) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acrylate concentration/content","parameters_en":[{"name":"Range","range":"(0,020 – 3266) mg/m3"},{"name":"Range","range":"(0,00120 – 4,90) mg w próbce"}],"search_en":"Waste gases Methyl acrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,020 – 3266) mg/m3"},{"name":"范围","range":"(0,00120 – 4,90) mg w próbce"}],"search_zh":"废气 丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丙烯酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47ec","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość izopentanu (2-metylobutanu)","parameters":[{"name":"Zakres","range":"(0,0120 – 4066) mg/m3"},{"name":"Zakres","range":"(0,00070 – 6,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość izopentanu (2-metylobutanu)\nZakres:\nZakres (0,0120 – 4066) mg/m3\nZakres (0,00070 – 6,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość izopentanu (2-metylobutanu)\nZakres:\nZakres (0,0120 – 4066) mg/m3\nZakres (0,00070 – 6,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc izopentanu (2-metylobutanu)\nZakres:\nZakres (0,0120 – 4066) mg/m3\nZakres (0,00070 – 6,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0120 – 4066) mg/m3"},{"name":"Range","range":"(0,00070 – 6,10) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0120 – 4066) mg/m3"},{"name":"范围","range":"(0,00070 – 6,10) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47ed","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metakrylanu butylu","parameters":[{"name":"Zakres","range":"(0,0190 – 3066) mg/m3"},{"name":"Zakres","range":"(0,00110 – 4,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,0190 – 3066) mg/m3\nZakres (0,00110 – 4,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,0190 – 3066) mg/m3\nZakres (0,00110 – 4,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc metakrylanu butylu\nZakres:\nZakres (0,0190 – 3066) mg/m3\nZakres (0,00110 – 4,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of butyl methacrylate","parameters_en":[{"name":"Range","range":"(0,0190 – 3066) mg/m3"},{"name":"Range","range":"(0,00110 – 4,60) mg w próbce"}],"search_en":"Waste gases Concentration/content of butyl methacrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0190 – 3066) mg/m3"},{"name":"范围","range":"(0,00110 – 4,60) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47ee","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metylocykloheksanu","parameters":[{"name":"Zakres","range":"(0,0250 – 16200) mg/m3"},{"name":"Zakres","range":"(0,00150 – 24,30) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metylocykloheksanu\nZakres:\nZakres (0,0250 – 16200) mg/m3\nZakres (0,00150 – 24,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metylocykloheksanu\nZakres:\nZakres (0,0250 – 16200) mg/m3\nZakres (0,00150 – 24,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc metylocykloheksanu\nZakres:\nZakres (0,0250 – 16200) mg/m3\nZakres (0,00150 – 24,30) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of methylcyclohexane","parameters_en":[{"name":"Range","range":"(0,0250 – 16200) mg/m3"},{"name":"Range","range":"(0,00150 – 24,30) mg w próbce"}],"search_en":"Waste gases Concentration/content of methylcyclohexane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0250 – 16200) mg/m3"},{"name":"范围","range":"(0,00150 – 24,30) mg w próbce"}],"search_zh":"废气 甲基环己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲基环己烷的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47ef","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu-2-butoksyetylu","parameters":[{"name":"Zakres","range":"(0,0120 – 1000) mg/m3"},{"name":"Zakres","range":"(0,000710 – 1,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-butoksyetylu\nZakres:\nZakres (0,0120 – 1000) mg/m3\nZakres (0,000710 – 1,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu-2-butoksyetylu\nZakres:\nZakres (0,0120 – 1000) mg/m3\nZakres (0,000710 – 1,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu-2-butoksyetylu\nZakres:\nZakres (0,0120 – 1000) mg/m3\nZakres (0,000710 – 1,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0120 – 1000) mg/m3"},{"name":"Range","range":"(0,000710 – 1,50) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0120 – 1000) mg/m3"},{"name":"范围","range":"(0,000710 – 1,50) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f0","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu-2-etoksyetylu","parameters":[{"name":"Zakres","range":"(0,0190 – 3133) mg/m3"},{"name":"Zakres","range":"(0,00110 – 4,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-etoksyetylu\nZakres:\nZakres (0,0190 – 3133) mg/m3\nZakres (0,00110 – 4,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu-2-etoksyetylu\nZakres:\nZakres (0,0190 – 3133) mg/m3\nZakres (0,00110 – 4,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu-2-etoksyetylu\nZakres:\nZakres (0,0190 – 3133) mg/m3\nZakres (0,00110 – 4,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0190 – 3133) mg/m3"},{"name":"Range","range":"(0,00110 – 4,70) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0190 – 3133) mg/m3"},{"name":"范围","range":"(0,00110 – 4,70) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f1","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu-2-metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(0,0250 – 15800) mg/m3"},{"name":"Zakres","range":"(0,00145 – 23,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,0250 – 15800) mg/m3\nZakres (0,00145 – 23,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,0250 – 15800) mg/m3\nZakres (0,00145 – 23,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu-2-metoksy-1-metyloetylu\nZakres:\nZakres (0,0250 – 15800) mg/m3\nZakres (0,00145 – 23,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0250 – 15800) mg/m3"},{"name":"Range","range":"(0,00145 – 23,70) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0250 – 15800) mg/m3"},{"name":"范围","range":"(0,00145 – 23,70) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f2","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu-2-metoksyetylu","parameters":[{"name":"Zakres","range":"(0,0150 – 2466) mg/m3"},{"name":"Zakres","range":"(0,00090 – 3,70) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu-2-metoksyetylu\nZakres:\nZakres (0,0150 – 2466) mg/m3\nZakres (0,00090 – 3,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu-2-metoksyetylu\nZakres:\nZakres (0,0150 – 2466) mg/m3\nZakres (0,00090 – 3,70) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu-2-metoksyetylu\nZakres:\nZakres (0,0150 – 2466) mg/m3\nZakres (0,00090 – 3,70) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0150 – 2466) mg/m3"},{"name":"Range","range":"(0,00090 – 3,70) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 2466) mg/m3"},{"name":"范围","range":"(0,00090 – 3,70) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f3","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu izobutylu","parameters":[{"name":"Zakres","range":"(0,01840 – 12133) mg/m3"},{"name":"Zakres","range":"(0,00110 – 18,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izobutylu\nZakres:\nZakres (0,01840 – 12133) mg/m3\nZakres (0,00110 – 18,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu izobutylu\nZakres:\nZakres (0,01840 – 12133) mg/m3\nZakres (0,00110 – 18,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu izobutylu\nZakres:\nZakres (0,01840 – 12133) mg/m3\nZakres (0,00110 – 18,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isobutyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,01840 – 12133) mg/m3"},{"name":"Range","range":"(0,00110 – 18,20) mg w próbce"}],"search_en":"Waste gases Isobutyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,01840 – 12133) mg/m3"},{"name":"范围","range":"(0,00110 – 18,20) mg w próbce"}],"search_zh":"废气 乙酸异丁酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙酸异丁酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47f4","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu metylu","parameters":[{"name":"Zakres","range":"(0,0190 – 6066) mg/m3"},{"name":"Zakres","range":"(0,00110 – 9,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu metylu\nZakres:\nZakres (0,0190 – 6066) mg/m3\nZakres (0,00110 – 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu metylu\nZakres:\nZakres (0,0190 – 6066) mg/m3\nZakres (0,00110 – 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu metylu\nZakres:\nZakres (0,0190 – 6066) mg/m3\nZakres (0,00110 – 9,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(0,0190 – 6066) mg/m3"},{"name":"Range","range":"(0,00110 – 9,10) mg w próbce"}],"search_en":"Waste gases Methyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0190 – 6066) mg/m3"},{"name":"范围","range":"(0,00110 – 9,10) mg w próbce"}],"search_zh":"废气 乙酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙酸甲酯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47f5","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu propylu","parameters":[{"name":"Zakres","range":"(0,0150 – 10066) mg/m3"},{"name":"Zakres","range":"(0,00090 – 15,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu propylu\nZakres:\nZakres (0,0150 – 10066) mg/m3\nZakres (0,00090 – 15,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu propylu\nZakres:\nZakres (0,0150 – 10066) mg/m3\nZakres (0,00090 – 15,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu propylu\nZakres:\nZakres (0,0150 – 10066) mg/m3\nZakres (0,00090 – 15,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of propyl acetate","parameters_en":[{"name":"Range","range":"(0,0150 – 10066) mg/m3"},{"name":"Range","range":"(0,00090 – 15,10) mg w próbce"}],"search_en":"Waste gases Concentration/content of propyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 10066) mg/m3"},{"name":"范围","range":"(0,00090 – 15,10) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f6","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)","parameters":[{"name":"Zakres","range":"(0,0150 – 4933) mg/m3"},{"name":"Zakres","range":"(0,00090 – 7,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,0150 – 4933) mg/m3\nZakres (0,00090 – 7,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,0150 – 4933) mg/m3\nZakres (0,00090 – 7,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 4-hydroksy-4-metylopentan-2-onu (alkoholu diacetonowego)\nZakres:\nZakres (0,0150 – 4933) mg/m3\nZakres (0,00090 – 7,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0150 – 4933) mg/m3"},{"name":"Range","range":"(0,00090 – 7,40) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 4933) mg/m3"},{"name":"范围","range":"(0,00090 – 7,40) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f7","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu izopropylu","parameters":[{"name":"Zakres","range":"(0,0150 – 10133) mg/m3"},{"name":"Zakres","range":"(0,00090 – 15,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izopropylu\nZakres:\nZakres (0,0150 – 10133) mg/m3\nZakres (0,00090 – 15,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu izopropylu\nZakres:\nZakres (0,0150 – 10133) mg/m3\nZakres (0,00090 – 15,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu izopropylu\nZakres:\nZakres (0,0150 – 10133) mg/m3\nZakres (0,00090 – 15,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of isopropyl acetate","parameters_en":[{"name":"Range","range":"(0,0150 – 10133) mg/m3"},{"name":"Range","range":"(0,00090 – 15,20) mg w próbce"}],"search_en":"Waste gases Concentration/content of isopropyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 10133) mg/m3"},{"name":"范围","range":"(0,00090 – 15,20) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47f8","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chlorobenzenu","parameters":[{"name":"Zakres","range":"(0,0270 – 4133) mg/m3"},{"name":"Zakres","range":"(0,00160 – 6,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chlorobenzenu\nZakres:\nZakres (0,0270 – 4133) mg/m3\nZakres (0,00160 – 6,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chlorobenzenu\nZakres:\nZakres (0,0270 – 4133) mg/m3\nZakres (0,00160 – 6,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc chlorobenzenu\nZakres:\nZakres (0,0270 – 4133) mg/m3\nZakres (0,00160 – 6,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene concentration/content","parameters_en":[{"name":"Range","range":"(0,0270 – 4133) mg/m3"},{"name":"Range","range":"(0,00160 – 6,20) mg w próbce"}],"search_en":"Waste gases Chlorobenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0270 – 4133) mg/m3"},{"name":"范围","range":"(0,00160 – 6,20) mg w próbce"}],"search_zh":"废气 氯苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"氯苯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47f9","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chloroformu","parameters":[{"name":"Zakres","range":"(0,020 – 400) mg/m3"},{"name":"Zakres","range":"(0,00120 – 0,60) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroformu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00120 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chloroformu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00120 – 0,60) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc chloroformu\nZakres:\nZakres (0,020 – 400) mg/m3\nZakres (0,00120 – 0,60) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroform","parameters_en":[{"name":"Range","range":"(0,020 – 400) mg/m3"},{"name":"Range","range":"(0,00120 – 0,60) mg w próbce"}],"search_en":"Waste gases Concentration/content of chloroform Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,020 – 400) mg/m3"},{"name":"范围","range":"(0,00120 – 0,60) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47fa","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość n-propylobenzenu","parameters":[{"name":"Zakres","range":"(0,0170 – 2733) mg/m3"},{"name":"Zakres","range":"(0,00100 – 4,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość n-propylobenzenu\nZakres:\nZakres (0,0170 – 2733) mg/m3\nZakres (0,00100 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość n-propylobenzenu\nZakres:\nZakres (0,0170 – 2733) mg/m3\nZakres (0,00100 – 4,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc n-propylobenzenu\nZakres:\nZakres (0,0170 – 2733) mg/m3\nZakres (0,00100 – 4,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"n-Propylbenzene concentration/content","parameters_en":[{"name":"Range","range":"(0,0170 – 2733) mg/m3"},{"name":"Range","range":"(0,00100 – 4,10) mg w próbce"}],"search_en":"Waste gases n-Propylbenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0170 – 2733) mg/m3"},{"name":"范围","range":"(0,00100 – 4,10) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47fb","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 1-etoksypropan-2-olu","parameters":[{"name":"Zakres","range":"(0,0190 – 2866) mg/m3"},{"name":"Zakres","range":"(0,00100 – 4,30) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1-etoksypropan-2-olu\nZakres:\nZakres (0,0190 – 2866) mg/m3\nZakres (0,00100 – 4,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 1-etoksypropan-2-olu\nZakres:\nZakres (0,0190 – 2866) mg/m3\nZakres (0,00100 – 4,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 1-etoksypropan-2-olu\nZakres:\nZakres (0,0190 – 2866) mg/m3\nZakres (0,00100 – 4,30) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 1-ethoxypropan-2-ol","parameters_en":[{"name":"Range","range":"(0,0190 – 2866) mg/m3"},{"name":"Range","range":"(0,00100 – 4,30) mg w próbce"}],"search_en":"Waste gases Concentration/content of 1-ethoxypropan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0190 – 2866) mg/m3"},{"name":"范围","range":"(0,00100 – 4,30) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47fc","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,01670 – 68) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,103) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,01670 – 68) mg/m3\nZakres (0,0010 – 0,103) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","norm_bases":["PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r.","na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,01670 – 68) mg/m3\nZakres (0,0010 – 0,103) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52 Gazy odlotowe Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,01670 – 68) mg/m3\nZakres (0,0010 – 0,103) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","categories":["other"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,01670 – 68) mg/m3"},{"name":"Range","range":"(0,0010 – 0,103) mg w próbce"}],"search_en":"Waste gases Formaldehyde concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,01670 – 68) mg/m3"},{"name":"范围","range":"(0,0010 – 0,103) mg w próbce"}],"search_zh":"废气 甲醛浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005 EV-IR-52 wyd. 1 z dn. 14.10.2019 r. | na podstawie NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 oraz OSHA Method 52","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲醛浓度/含量"},{"_id":"6a82eafc884ede9a1b2c47fd","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)","parameters":[{"name":"Zakres","range":"(0,0160 – 2533) mg/m3"},{"name":"Zakres","range":"(0,000940 – 3,80) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,0160 – 2533) mg/m3\nZakres (0,000940 – 3,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,0160 – 2533) mg/m3\nZakres (0,000940 – 3,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc epichlorohydryny (1-chloro 2,3-epoksypropanu)\nZakres:\nZakres (0,0160 – 2533) mg/m3\nZakres (0,000940 – 3,80) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0160 – 2533) mg/m3"},{"name":"Range","range":"(0,000940 – 3,80) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0160 – 2533) mg/m3"},{"name":"范围","range":"(0,000940 – 3,80) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47fe","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-(2-butoksyetoksy) etanolu","parameters":[{"name":"Zakres","range":"(0,075 – 3060) mg/m3"},{"name":"Zakres","range":"(0,00450 – 4,59) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,075 – 3060) mg/m3\nZakres (0,00450 – 4,59) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,075 – 3060) mg/m3\nZakres (0,00450 – 4,59) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (0,075 – 3060) mg/m3\nZakres (0,00450 – 4,59) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-(2-butoxyethoxy) ethanol","parameters_en":[{"name":"Range","range":"(0,075 – 3060) mg/m3"},{"name":"Range","range":"(0,00450 – 4,59) mg w próbce"}],"search_en":"Waste gases Concentration/content of 2-(2-butoxyethoxy) ethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,075 – 3060) mg/m3"},{"name":"范围","range":"(0,00450 – 4,59) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c47ff","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(0,11 – 2133) mg/m3"},{"name":"Zakres","range":"(0,00650 – 3,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,11 – 2133) mg/m3\nZakres (0,00650 – 3,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,11 – 2133) mg/m3\nZakres (0,00650 – 3,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (0,11 – 2133) mg/m3\nZakres (0,00650 – 3,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol concentration/content","parameters_en":[{"name":"Range","range":"(0,11 – 2133) mg/m3"},{"name":"Range","range":"(0,00650 – 3,20) mg w próbce"}],"search_en":"Waste gases Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,11 – 2133) mg/m3"},{"name":"范围","range":"(0,00650 – 3,20) mg w próbce"}],"search_zh":"废气 乙二醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4800","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-metoksyetanolu","parameters":[{"name":"Zakres","range":"(0,050 – 2066) mg/m3"},{"name":"Zakres","range":"(0,0030 – 3,1) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-metoksyetanolu\nZakres:\nZakres (0,050 – 2066) mg/m3\nZakres (0,0030 – 3,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-metoksyetanolu\nZakres:\nZakres (0,050 – 2066) mg/m3\nZakres (0,0030 – 3,1) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-metoksyetanolu\nZakres:\nZakres (0,050 – 2066) mg/m3\nZakres (0,0030 – 3,1) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-methoxyethanol","parameters_en":[{"name":"Range","range":"(0,050 – 2066) mg/m3"},{"name":"Range","range":"(0,0030 – 3,1) mg w próbce"}],"search_en":"Waste gases Concentration/content of 2-methoxyethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,050 – 2066) mg/m3"},{"name":"范围","range":"(0,0030 – 3,1) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4801","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość krezolu – mieszanina izomerów","parameters":[{"name":"Zakres","range":"(0,029 – 280) mg/m3"},{"name":"Zakres","range":"(0,00170 – 0,42) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość krezolu – mieszanina izomerów\nZakres:\nZakres (0,029 – 280) mg/m3\nZakres (0,00170 – 0,42) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość krezolu – mieszanina izomerów\nZakres:\nZakres (0,029 – 280) mg/m3\nZakres (0,00170 – 0,42) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc krezolu – mieszanina izomerow\nZakres:\nZakres (0,029 – 280) mg/m3\nZakres (0,00170 – 0,42) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cresol concentration/content – mixture of isomers","parameters_en":[{"name":"Range","range":"(0,029 – 280) mg/m3"},{"name":"Range","range":"(0,00170 – 0,42) mg w próbce"}],"search_en":"Waste gases Cresol concentration/content – mixture of isomers Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,029 – 280) mg/m3"},{"name":"范围","range":"(0,00170 – 0,42) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4802","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość kwasu akrylowego","parameters":[{"name":"Zakres","range":"(0,33 – 3466) mg/m3"},{"name":"Zakres","range":"(0,020 – 5,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (0,33 – 3466) mg/m3\nZakres (0,020 – 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (0,33 – 3466) mg/m3\nZakres (0,020 – 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc kwasu akrylowego\nZakres:\nZakres (0,33 – 3466) mg/m3\nZakres (0,020 – 5,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,33 – 3466) mg/m3"},{"name":"Range","range":"(0,020 – 5,2) mg w próbce"}],"search_en":"Waste gases Acrylic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,33 – 3466) mg/m3"},{"name":"范围","range":"(0,020 – 5,2) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4803","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość trichloroetenu","parameters":[{"name":"Zakres","range":"(0,017 – 5466) mg/m3"},{"name":"Zakres","range":"(0,0010 – 8,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość trichloroetenu\nZakres:\nZakres (0,017 – 5466) mg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość trichloroetenu\nZakres:\nZakres (0,017 – 5466) mg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc trichloroetenu\nZakres:\nZakres (0,017 – 5466) mg/m3\nZakres (0,0010 – 8,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichloroethene concentration/content","parameters_en":[{"name":"Range","range":"(0,017 – 5466) mg/m3"},{"name":"Range","range":"(0,0010 – 8,20) mg w próbce"}],"search_en":"Waste gases Trichloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,017 – 5466) mg/m3"},{"name":"范围","range":"(0,0010 – 8,20) mg w próbce"}],"search_zh":"废气 三氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"三氯乙烯的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4804","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,02 – 200) mg/m3"},{"name":"Zakres","range":"(0,0012 – 0,3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (0,02 – 200) mg/m3\nZakres (0,0012 – 0,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metanolu\nZakres:\nZakres (0,02 – 200) mg/m3\nZakres (0,0012 – 0,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc metanolu\nZakres:\nZakres (0,02 – 200) mg/m3\nZakres (0,0012 – 0,3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol concentration/content","parameters_en":[{"name":"Range","range":"(0,02 – 200) mg/m3"},{"name":"Range","range":"(0,0012 – 0,3) mg w próbce"}],"search_en":"Waste gases Methanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,02 – 200) mg/m3"},{"name":"范围","range":"(0,0012 – 0,3) mg w próbce"}],"search_zh":"废气 甲醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲醇的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4805","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość propan-1-olu","parameters":[{"name":"Zakres","range":"(0,01840 – 2800) mg/m3"},{"name":"Zakres","range":"(0,00110 – 4,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-1-olu\nZakres:\nZakres (0,01840 – 2800) mg/m3\nZakres (0,00110 – 4,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość propan-1-olu\nZakres:\nZakres (0,01840 – 2800) mg/m3\nZakres (0,00110 – 4,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc propan-1-olu\nZakres:\nZakres (0,01840 – 2800) mg/m3\nZakres (0,00110 – 4,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of propan-1-ol","parameters_en":[{"name":"Range","range":"(0,01840 – 2800) mg/m3"},{"name":"Range","range":"(0,00110 – 4,20) mg w próbce"}],"search_en":"Waste gases Concentration/content of propan-1-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,01840 – 2800) mg/m3"},{"name":"范围","range":"(0,00110 – 4,20) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4806","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość acetaldehydu","parameters":[{"name":"Zakres","range":"(0,01670 – 400) mg/m3"},{"name":"Zakres","range":"(0,00100 – 0,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetaldehydu\nZakres:\nZakres (0,01670 – 400) mg/m3\nZakres (0,00100 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość acetaldehydu\nZakres:\nZakres (0,01670 – 400) mg/m3\nZakres (0,00100 – 0,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc acetaldehydu\nZakres:\nZakres (0,01670 – 400) mg/m3\nZakres (0,00100 – 0,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acetaldehyde","parameters_en":[{"name":"Range","range":"(0,01670 – 400) mg/m3"},{"name":"Range","range":"(0,00100 – 0,6) mg w próbce"}],"search_en":"Waste gases Concentration/content of acetaldehyde Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,01670 – 400) mg/m3"},{"name":"范围","range":"(0,00100 – 0,6) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4807","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość furfuralu","parameters":[{"name":"Zakres","range":"(0,01840 – 1400) mg/m3"},{"name":"Zakres","range":"(0,00110 – 2,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość furfuralu\nZakres:\nZakres (0,01840 – 1400) mg/m3\nZakres (0,00110 – 2,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość furfuralu\nZakres:\nZakres (0,01840 – 1400) mg/m3\nZakres (0,00110 – 2,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc furfuralu\nZakres:\nZakres (0,01840 – 1400) mg/m3\nZakres (0,00110 – 2,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,01840 – 1400) mg/m3"},{"name":"Range","range":"(0,00110 – 2,10) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,01840 – 1400) mg/m3"},{"name":"范围","range":"(0,00110 – 2,10) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4808","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość akrylaldehydu (akroleiny)","parameters":[{"name":"Zakres","range":"(0,0040 – 20,0) mg/m3"},{"name":"Zakres","range":"(0,000240 – 0,030) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040 – 20,0) mg/m3\nZakres (0,000240 – 0,030) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040 – 20,0) mg/m3\nZakres (0,000240 – 0,030) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc akrylaldehydu (akroleiny)\nZakres:\nZakres (0,0040 – 20,0) mg/m3\nZakres (0,000240 – 0,030) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acrylaldehyde (acrolein)","parameters_en":[{"name":"Range","range":"(0,0040 – 20,0) mg/m3"},{"name":"Range","range":"(0,000240 – 0,030) mg w próbce"}],"search_en":"Waste gases Concentration/content of acrylaldehyde (acrolein) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0040 – 20,0) mg/m3"},{"name":"范围","range":"(0,000240 – 0,030) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4809","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość acetonitrylu","parameters":[{"name":"Zakres","range":"(0,79 – 1000) mg/m3"},{"name":"Zakres","range":"(0,047 – 1,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetonitrylu\nZakres:\nZakres (0,79 – 1000) mg/m3\nZakres (0,047 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość acetonitrylu\nZakres:\nZakres (0,79 – 1000) mg/m3\nZakres (0,047 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc acetonitrylu\nZakres:\nZakres (0,79 – 1000) mg/m3\nZakres (0,047 – 1,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acetonitrile","parameters_en":[{"name":"Range","range":"(0,79 – 1000) mg/m3"},{"name":"Range","range":"(0,047 – 1,5) mg w próbce"}],"search_en":"Waste gases Concentration/content of acetonitrile Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,79 – 1000) mg/m3"},{"name":"范围","range":"(0,047 – 1,5) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość cykloheksanolu","parameters":[{"name":"Zakres","range":"(0,17 – 3333) mg/m3"},{"name":"Zakres","range":"(0,0098 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanolu\nZakres:\nZakres (0,17 – 3333) mg/m3\nZakres (0,0098 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość cykloheksanolu\nZakres:\nZakres (0,17 – 3333) mg/m3\nZakres (0,0098 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc cykloheksanolu\nZakres:\nZakres (0,17 – 3333) mg/m3\nZakres (0,0098 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cyclohexanol","parameters_en":[{"name":"Range","range":"(0,17 – 3333) mg/m3"},{"name":"Range","range":"(0,0098 – 5) mg w próbce"}],"search_en":"Waste gases Concentration/content of cyclohexanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,17 – 3333) mg/m3"},{"name":"范围","range":"(0,0098 – 5) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość fenylometanolu (alkoholu benzylowego)","parameters":[{"name":"Zakres","range":"(0,10 – 8000) mg/m3"},{"name":"Zakres","range":"(0,0059 – 12) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,10 – 8000) mg/m3\nZakres (0,0059 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,10 – 8000) mg/m3\nZakres (0,0059 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc fenylometanolu (alkoholu benzylowego)\nZakres:\nZakres (0,10 – 8000) mg/m3\nZakres (0,0059 – 12) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of phenylmethanol (benzyl alcohol)","parameters_en":[{"name":"Range","range":"(0,10 – 8000) mg/m3"},{"name":"Range","range":"(0,0059 – 12) mg w próbce"}],"search_en":"Waste gases Concentration/content of phenylmethanol (benzyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,10 – 8000) mg/m3"},{"name":"范围","range":"(0,0059 – 12) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu amylu (octanu pentylu)","parameters":[{"name":"Zakres","range":"(0,65 – 3333) mg/m3"},{"name":"Zakres","range":"(0,039 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu amylu (octanu pentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu amylu (octanu pentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu amylu (octanu pentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,65 – 3333) mg/m3"},{"name":"Range","range":"(0,039 – 5) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,65 – 3333) mg/m3"},{"name":"范围","range":"(0,039 – 5) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość octanu izoamylu (octanu izopentylu)","parameters":[{"name":"Zakres","range":"(0,65 – 3333) mg/m3"},{"name":"Zakres","range":"(0,039 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc octanu izoamylu (octanu izopentylu)\nZakres:\nZakres (0,65 – 3333) mg/m3\nZakres (0,039 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,65 – 3333) mg/m3"},{"name":"Range","range":"(0,039 – 5) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,65 – 3333) mg/m3"},{"name":"范围","range":"(0,039 – 5) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-etyloheksan-1-olu","parameters":[{"name":"Zakres","range":"(0,17 – 866) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-etyloheksan-1-olu\nZakres:\nZakres (0,17 – 866) mg/m3\nZakres (0,010 – 1,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-etyloheksan-1-olu\nZakres:\nZakres (0,17 – 866) mg/m3\nZakres (0,010 – 1,3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-etyloheksan-1-olu\nZakres:\nZakres (0,17 – 866) mg/m3\nZakres (0,010 – 1,3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,17 – 866) mg/m3"},{"name":"Range","range":"(0,010 – 1,3) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,17 – 866) mg/m3"},{"name":"范围","range":"(0,010 – 1,3) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c480f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość 2-furylometanolu","parameters":[{"name":"Zakres","range":"(0,32 – 800) mg/m3"},{"name":"Zakres","range":"(0,019 – 1,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-furylometanolu\nZakres:\nZakres (0,32 – 800) mg/m3\nZakres (0,019 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość 2-furylometanolu\nZakres:\nZakres (0,32 – 800) mg/m3\nZakres (0,019 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc 2-furylometanolu\nZakres:\nZakres (0,32 – 800) mg/m3\nZakres (0,019 – 1,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,32 – 800) mg/m3"},{"name":"Range","range":"(0,019 – 1,2) mg w próbce"}],"search_en":"Waste gases Gas chromatography with flame ionization detection (GC-FID) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,32 – 800) mg/m3"},{"name":"范围","range":"(0,019 – 1,2) mg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4810","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c4811","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(8,0 - 1280) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (8,0 - 1280) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (8,0 - 1280) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (8,0 - 1280) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(8,0 - 1280) mg/m3"}],"search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(8,0 - 1280) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a82eafc884ede9a1b2c4812","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c4813","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru","reference":"EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","norm_bases":["EV-PB-5 wydanie 3 z dnia 31.03.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia siarkowodoru EV-PB-5 wydanie 3 z dnia 31.03.2025 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia siarkowodoru EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","categories":["other"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen sulphide concentration","search_en":"Waste gases Sampling for determination of hydrogen sulphide concentration EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","test_object_en":"Waste gases","search_zh":"废气 用于测定硫化氢浓度的采样 EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","test_object_zh":"废气","methodology_zh":"用于测定硫化氢浓度的采样"},{"_id":"6a82eafc884ede9a1b2c4814","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja siarkowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja siarkowodoru (z obliczeń)","reference":"EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","norm_bases":["EV-PB-5 wydanie 3 z dnia 31.03.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja siarkowodoru (z obliczeń) EV-PB-5 wydanie 3 z dnia 31.03.2025 r. Gazy odlotowe Emisja siarkowodoru (z obliczen) EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","categories":["environment"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide emission (calculated)","search_en":"Waste gases Hydrogen sulphide emission (calculated) EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","test_object_en":"Waste gases","search_zh":"废气 硫化氢排放（由计算得出） EV-PB-5 wydanie 3 z dnia 31.03.2025 r.","test_object_zh":"废气","methodology_zh":"硫化氢排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c4815","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,830 – 66,7) mg/m3"},{"name":"Zakres","range":"(0,050 – 2,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,830 – 66,7) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda spektrofotometryczna","reference":"EV-PB-7 wydanie 2 z dnia 17.04.2018 r.","norm_bases":["EV-PB-7 wydanie 2 z dnia 17.04.2018 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,830 – 66,7) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda spektrofotometryczna EV-PB-7 wydanie 2 z dnia 17.04.2018 r. Gazy odlotowe Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,830 – 66,7) mg/m3\nZakres (0,050 – 2,0) mg w probce\nMetoda spektrofotometryczna EV-PB-7 wydanie 2 z dnia 17.04.2018 r.","categories":["other"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,830 – 66,7) mg/m3"},{"name":"Range","range":"(0,050 – 2,0) mg w próbce"}],"search_en":"Waste gases Hydrogen sulphide concentration/content Spectrophotometric method Range Range EV-PB-7 wydanie 2 z dnia 17.04.2018 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,830 – 66,7) mg/m3"},{"name":"范围","range":"(0,050 – 2,0) mg w próbce"}],"search_zh":"废气 硫化氢的浓度/含量 分光光度法 范围 范围 EV-PB-7 wydanie 2 z dnia 17.04.2018 r.","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4816","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczania stężenia PM 1, PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczania stężenia PM 1, PM 2,5 i PM 10","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania stężenia PM 1, PM 2,5 i PM 10 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r. Gazy odlotowe Pobieranie probek pylu do oznaczania stezenia PM 1, PM 2,5 i PM 10 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","categories":["other"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4817","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu PM 1, PM 2,5 i PM 10 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu PM 1, PM 2,5 i PM 10 (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu PM 1, PM 2,5 i PM 10 (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r. Gazy odlotowe Emisja pylu PM 1, PM 2,5 i PM 10 (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","categories":["environment"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 wydanie 2 z dnia 26.03.2026 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4818","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia ozonu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia ozonu","reference":"EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-11 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia ozonu EV-PB-11 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia ozonu EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","categories":["other"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of ozone concentration","search_en":"Waste gases Sampling for the determination of ozone concentration EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 用于测定臭氧浓度的采样 EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气","methodology_zh":"用于测定臭氧浓度的采样"},{"_id":"6a82eafc884ede9a1b2c4819","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0150 – 0,450) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,0180) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 – 0,0180) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994 z wyłączeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r.","norm_bases":["PN-Z-04007-2:1994 z wyłączeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 – 0,0180) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 z wyłączeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r. Gazy odlotowe Stezenie/zawartosc ozonu\nZakres:\nZakres (0,0150 – 0,450) mg/m3\nZakres (0,0010 – 0,0180) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 z wylaczeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r.","categories":["other"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,0150 – 0,450) mg/m3"},{"name":"Range","range":"(0,0010 – 0,0180) mg w próbce"}],"search_en":"Waste gases Ozone concentration/content Spectrophotometric method Range Range PN-Z-04007-2:1994 z wyłączeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0150 – 0,450) mg/m3"},{"name":"范围","range":"(0,0010 – 0,0180) mg w próbce"}],"search_zh":"废气 臭氧的浓度/含量 分光光度法 范围 范围 PN-Z-04007-2:1994 z wyłączeniem pkt. 7 EV-IR-53 wydanie 1 z dnia 14.10.2019 r.","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c481a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja ozonu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja ozonu (z obliczeń)","reference":"EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-11 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja ozonu (z obliczeń) EV-PB-11 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Emisja ozonu (z obliczen) EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","categories":["environment"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone emission (calculated)","search_en":"Waste gases Ozone emission (calculated) EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 臭氧排放（由计算得出） EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气","methodology_zh":"臭氧排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c481b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia formaldehydu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia formaldehydu","reference":"EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-11 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia formaldehydu EV-PB-11 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia formaldehydu EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","categories":["other"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of formaldehyde concentration","search_en":"Waste gases Sampling for determination of formaldehyde concentration EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 用于测定甲醛浓度的采样 EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气","methodology_zh":"用于测定甲醛浓度的采样"},{"_id":"6a82eafc884ede9a1b2c481c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0670 – 66) mg/m3"},{"name":"Zakres","range":"(0,0040 – 0,40) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0670 – 66) mg/m3\nZakres (0,0040 – 0,40) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020","norm_bases":["PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0670 – 66) mg/m3\nZakres (0,0040 – 0,40) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020 Gazy odlotowe Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,0670 – 66) mg/m3\nZakres (0,0040 – 0,40) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020","categories":["other"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,0670 – 66) mg/m3"},{"name":"Range","range":"(0,0040 – 0,40) mg w próbce"}],"search_en":"Waste gases Formaldehyde concentration/content Spectrophotometric method Range Range PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0670 – 66) mg/m3"},{"name":"范围","range":"(0,0040 – 0,40) mg w próbce"}],"search_zh":"废气 甲醛浓度/含量 分光光度法 范围 范围 PN-76/Z-04045/02 i EV-IR/54 wydanie 1 z dnia 31.01.2020","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"甲醛浓度/含量"},{"_id":"6a82eafc884ede9a1b2c481d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja formaldehydu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja formaldehydu (z obliczeń)","reference":"EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-11 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja formaldehydu (z obliczeń) EV-PB-11 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Emisja formaldehydu (z obliczen) EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","categories":["environment"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde emission (calculated)","search_en":"Waste gases Formaldehyde emission (calculated) EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 甲醛释放量（由计算得出） EV-PB-11 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气","methodology_zh":"甲醛释放量（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c481e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego","reference":"EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","norm_bases":["EV-PB-10 wydanie 3 z dnia 17.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia kwasu siarkowego EV-PB-10 wydanie 3 z dnia 17.03.2026 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia kwasu siarkowego EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","categories":["other"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of sulfuric acid concentration","search_en":"Waste gases Sampling for determination of sulfuric acid concentration EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","test_object_en":"Waste gases","search_zh":"废气 EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c481f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość kwasu siarkowego","parameters":[{"name":"Zakres","range":"(0,0190 – 29,9) mg/m3"},{"name":"Zakres","range":"(0,20 – 5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,0190 – 29,9) mg/m3\nZakres (0,20 – 5) mg w próbce\nMetoda spektrofotometryczna","reference":"EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","norm_bases":["EV-PB-10 wydanie 3 z dnia 17.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,0190 – 29,9) mg/m3\nZakres (0,20 – 5) mg w próbce\nMetoda spektrofotometryczna EV-PB-10 wydanie 3 z dnia 17.03.2026 r. Gazy odlotowe Stezenie/zawartosc kwasu siarkowego\nZakres:\nZakres (0,0190 – 29,9) mg/m3\nZakres (0,20 – 5) mg w probce\nMetoda spektrofotometryczna EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","categories":["other"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfuric acid concentration/content","parameters_en":[{"name":"Range","range":"(0,0190 – 29,9) mg/m3"},{"name":"Range","range":"(0,20 – 5) mg w próbce"}],"search_en":"Waste gases Sulfuric acid concentration/content Spectrophotometric method Range Range EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0190 – 29,9) mg/m3"},{"name":"范围","range":"(0,20 – 5) mg w próbce"}],"search_zh":"废气 硫酸的浓度/含量 分光光度法 范围 范围 EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"硫酸的浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4820","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja kwasu siarkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja kwasu siarkowego (z obliczeń)","reference":"EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","norm_bases":["EV-PB-10 wydanie 3 z dnia 17.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja kwasu siarkowego (z obliczeń) EV-PB-10 wydanie 3 z dnia 17.03.2026 r. Gazy odlotowe Emisja kwasu siarkowego (z obliczen) EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","categories":["environment"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfuric acid emission (calculated)","search_en":"Waste gases Sulfuric acid emission (calculated) EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","test_object_en":"Waste gases","search_zh":"废气 硫酸排放（由计算得出） EV-PB-10 wydanie 3 z dnia 17.03.2026 r.","test_object_zh":"废气","methodology_zh":"硫酸排放（由计算得出）"},{"_id":"6a82eafc884ede9a1b2c4821","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chromu (VI)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chromu (VI)","reference":"EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-9 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chromu (VI) EV-PB-9 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia chromu (VI) EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","categories":["other"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of chromium (VI) concentration","search_en":"Waste gases Sampling for determination of chromium (VI) concentration EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4822","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chromu (VI)","parameters":[{"name":"Zakres","range":"(0,0000910 – 0,0390) mg/m3"},{"name":"Zakres","range":"(0,00050 – 0,020) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chromu (VI)\nZakres:\nZakres (0,0000910 – 0,0390) mg/m3\nZakres (0,00050 – 0,020) mg w próbce\nMetoda spektrofotometryczna","reference":"EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-9 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chromu (VI)\nZakres:\nZakres (0,0000910 – 0,0390) mg/m3\nZakres (0,00050 – 0,020) mg w próbce\nMetoda spektrofotometryczna EV-PB-9 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Stezenie/zawartosc chromu (VI)\nZakres:\nZakres (0,0000910 – 0,0390) mg/m3\nZakres (0,00050 – 0,020) mg w probce\nMetoda spektrofotometryczna EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","categories":["other"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chromium (VI)","parameters_en":[{"name":"Range","range":"(0,0000910 – 0,0390) mg/m3"},{"name":"Range","range":"(0,00050 – 0,020) mg w próbce"}],"search_en":"Waste gases Concentration/content of chromium (VI) Spectrophotometric method Range Range EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,0000910 – 0,0390) mg/m3"},{"name":"范围","range":"(0,00050 – 0,020) mg w próbce"}],"search_zh":"废气 分光光度法 范围 范围 EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","technique_zh":"分光光度法","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4823","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja chromu (VI) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chromu (VI) (z obliczeń)","reference":"EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","norm_bases":["EV-PB-9 wydanie 2 z dnia 01.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja chromu (VI) (z obliczeń) EV-PB-9 wydanie 2 z dnia 01.04.2021 r. Gazy odlotowe Emisja chromu (VI) (z obliczen) EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","categories":["environment"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of chromium (VI) (calculated)","search_en":"Waste gases Emission of chromium (VI) (calculated) EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","test_object_en":"Waste gases","search_zh":"废气 EV-PB-9 wydanie 2 z dnia 01.04.2021 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c4824","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c4825","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,05 – 400) mg/m3"},{"name":"Zakres","range":"(0,005 – 12) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,05 – 400) mg/m3\nZakres (0,005 – 12) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość amoniaku\nZakres:\nZakres (0,05 – 400) mg/m3\nZakres (0,005 – 12) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,05 – 400) mg/m3\nZakres (0,005 – 12) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 400) mg/m3"},{"name":"Range","range":"(0,005 – 12) mg w próbce"}],"search_en":"Waste gases Ammonia concentration/content Spectrophotometric method Range Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,05 – 400) mg/m3"},{"name":"范围","range":"(0,005 – 12) mg w próbce"}],"search_zh":"废气 氨浓度/含量 分光光度法 范围 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氨浓度/含量"},{"_id":"6a82eafc884ede9a1b2c4826","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c4827","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Próbki pyłu","methodology":"Udział frakcji pyłu (skład ziarnowy) w tym PM 1; PM 2,5; PM 10","parameters":[{"name":"Zakres","range":"(0,1 – 3800) μm"},{"name":"Zakres","range":"(0 – 100) %"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Udział frakcji pyłu (skład ziarnowy) w tym PM 1; PM 2,5; PM 10\nZakres:\nZakres (0,1 – 3800) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej","reference":"ISO 13320:2020","norm_bases":["ISO 13320:2020"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki pyłu Udział frakcji pyłu (skład ziarnowy) w tym PM 1; PM 2,5; PM 10\nZakres:\nZakres (0,1 – 3800) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej ISO 13320:2020 Probki pylu Udzial frakcji pylu (sklad ziarnowy) w tym PM 1; PM 2,5; PM 10\nZakres:\nZakres (0,1 – 3800) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej ISO 13320:2020","categories":["other"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,1 – 3800) μm"},{"name":"Range","range":"(0 – 100) %"}],"search_en":"Dust samples Laser diffraction method Range Range ISO 13320:2020","technique_en":"Laser diffraction method","test_object_en":"Dust samples","parameters_zh":[{"name":"范围","range":"(0,1 – 3800) μm"},{"name":"范围","range":"(0 – 100) %"}],"search_zh":"粉尘样品 激光衍射法 范围 范围 ISO 13320:2020","technique_zh":"激光衍射法","test_object_zh":"粉尘样品"},{"_id":"6a82eafc884ede9a1b2c4828","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a82eafc884ede9a1b2c4829","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,1 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,1 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,1 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c482a","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a82eafc884ede9a1b2c482b","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: Zn, Fe, Sn","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: Zn, Fe, Sn","reference":"PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","norm_bases":["PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: Zn, Fe, Sn PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: Zn, Fe, Sn PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","categories":["materials"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations: Zn, Fe, Sn","search_en":"Waste gases Sampling for determination of metal concentrations: Zn, Fe, Sn PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c482c","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metali","parameters":[{"name":"Zn","range":"(0,000250 – 20) mg/m3"},{"name":"Zakres","range":"(0,00250 – 10) mg w próbce"},{"name":"Fe","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Sn","range":"(0,0250 – 20) mg/m3"},{"name":"(0,250 – 10) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość metali\nZakres:\nZn (0,000250 – 20) mg/m3\nZakres (0,00250 – 10) mg w próbce\nFe (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Sn (0,0250 – 20) mg/m3\n(0,250 – 10) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","norm_bases":["PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metali\nZakres:\nZn (0,000250 – 20) mg/m3\nZakres (0,00250 – 10) mg w próbce\nFe (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w próbce Sn (0,0250 – 20) mg/m3\n(0,250 – 10) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r. Gazy odlotowe Stezenie/zawartosc metali\nZakres:\nZn (0,000250 – 20) mg/m3\nZakres (0,00250 – 10) mg w probce\nFe (0,00050 – 20) mg/m3\n(0,0050 – 10) mg w probce Sn (0,0250 – 20) mg/m3\n(0,250 – 10) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","categories":["materials"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Zn","range":"(0,000250 – 20) mg/m3"},{"name":"Range","range":"(0,00250 – 10) mg w próbce"},{"name":"Fe","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Sn","range":"(0,0250 – 20) mg/m3"},{"name":"(0,250 – 10) mg w próbce"}],"search_en":"Waste gases Flame atomic absorption spectrometry (FAAS) Zn Range Fe PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Waste gases","parameters_zh":[{"name":"Zn","range":"(0,000250 – 20) mg/m3"},{"name":"范围","range":"(0,00250 – 10) mg w próbce"},{"name":"Fe","range":"(0,00050 – 20) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Sn","range":"(0,0250 – 20) mg/m3"},{"name":"(0,250 – 10) mg w próbce"}],"search_zh":"废气 火焰原子吸收光谱法（FAAS） Zn 范围 Fe PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c482d","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: Zn, Fe, Sn (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: Zn, Fe, Sn (z obliczeń)","reference":"PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","norm_bases":["PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali: Zn, Fe, Sn (z obliczeń) PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r. Gazy odlotowe Emisja metali: Zn, Fe, Sn (z obliczen) PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","categories":["materials","environment"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals: Zn, Fe, Sn (calculated)","search_en":"Waste gases Emission of metals: Zn, Fe, Sn (calculated) PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2005 EV-PB-16 wydanie 3 z dnia 25.03.2024 r.","test_object_zh":"废气"},{"_id":"6a82eafc884ede9a1b2c482e","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi – powietrze","methodology":"Pobieranie próbek do oznaczania stężenia związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia związków organicznych","reference":"EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","norm_bases":["EV-PB-14 wydanie 2 z dnia 28.03.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi – powietrze Pobieranie próbek do oznaczania stężenia związków organicznych EV-PB-14 wydanie 2 z dnia 28.03.2023 r. Pomieszczenia przeznaczone na pobyt ludzi – powietrze Pobieranie probek do oznaczania stezenia zwiazkow organicznych EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","categories":["environment"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of organic compound concentration","search_en":"Rooms intended for human occupancy – air Sampling for the determination of organic compound concentration EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","test_object_en":"Rooms intended for human occupancy – air","methodology_zh":"用于测定有机化合物浓度的采样","search_zh":"用于测定有机化合物浓度的采样 EV-PB-14 wydanie 2 z dnia 28.03.2023 r."},{"_id":"6a82eafc884ede9a1b2c482f","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie/Zawartość:","parameters":[{"name":"akrylonitryl"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"benzen"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"buta-1,3-dien"},{"name":"Zakres","range":"(9,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0012 – 0,60) mg w próbce"},{"name":"butan-1-ol (alkohol butylowy)"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"chlorek winylu"},{"name":"Zakres","range":"(4,9 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0007 – 0,70) mg w próbce"},{"name":"chlorobenzen"},{"name":"Zakres","range":"(3,2 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0016 – 6,20) mg w próbce"},{"name":"cykloheksan"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"cykloheksanon"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"etylobenzen"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"fenol"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,50) mg w próbce"},{"name":"formaldehyd"},{"name":"Zakres","range":"(7,0 – 600) μg/m3"},{"name":"Zakres","range":"(0,0010 – 0,100) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/Zawartość:\nZakres:\nakrylonitryl\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nbenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nbuta-1,3-dien\nZakres (9,0 – 4000) μg/m3\nZakres (0,0012 – 0,60) mg w próbce\nbutan-1-ol (alkohol butylowy)\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nchlorek winylu\nZakres (4,9 – 4000) μg/m3\nZakres (0,0007 – 0,70) mg w próbce\nchlorobenzen\nZakres (3,2 – 4000) μg/m3\nZakres (0,0016 – 6,20) mg w próbce\ncykloheksan\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ncykloheksanon\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\netylobenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nfenol\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,50) mg w próbce\nformaldehyd\nZakres (7,0 – 600) μg/m3\nZakres (0,0010 – 0,100) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","norm_bases":["EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Stężenie/Zawartość:\nZakres:\nakrylonitryl\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nbenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nbuta-1,3-dien\nZakres (9,0 – 4000) μg/m3\nZakres (0,0012 – 0,60) mg w próbce\nbutan-1-ol (alkohol butylowy)\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nchlorek winylu\nZakres (4,9 – 4000) μg/m3\nZakres (0,0007 – 0,70) mg w próbce\nchlorobenzen\nZakres (3,2 – 4000) μg/m3\nZakres (0,0016 – 6,20) mg w próbce\ncykloheksan\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ncykloheksanon\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\netylobenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nfenol\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,50) mg w próbce\nformaldehyd\nZakres (7,0 – 600) μg/m3\nZakres (0,0010 – 0,100) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Stezenie/Zawartosc:\nZakres:\nakrylonitryl\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\nbenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\nbuta-1,3-dien\nZakres (9,0 – 4000) μg/m3\nZakres (0,0012 – 0,60) mg w probce\nbutan-1-ol (alkohol butylowy)\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\nchlorek winylu\nZakres (4,9 – 4000) μg/m3\nZakres (0,0007 – 0,70) mg w probce\nchlorobenzen\nZakres (3,2 – 4000) μg/m3\nZakres (0,0016 – 6,20) mg w probce\ncykloheksan\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\ncykloheksanon\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\netylobenzen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\nfenol\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,50) mg w probce\nformaldehyd\nZakres (7,0 – 600) μg/m3\nZakres (0,0010 – 0,100) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","categories":["environment"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/Content:","parameters_en":[{"name":"acrylonitrile"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"benzene"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"buta-1,3-diene"},{"name":"Range","range":"(9,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0012 – 0,60) mg w próbce"},{"name":"butan-1-ol (butyl alcohol)"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"vinyl chloride"},{"name":"Range","range":"(4,9 – 4000) μg/m3"},{"name":"Range","range":"(0,0007 – 0,70) mg w próbce"},{"name":"chlorobenzene"},{"name":"Range","range":"(3,2 – 4000) μg/m3"},{"name":"Range","range":"(0,0016 – 6,20) mg w próbce"},{"name":"cyclohexane"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"cyclohexanone"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"ethylbenzene"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"phenol"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,50) mg w próbce"},{"name":"formaldehyde"},{"name":"Range","range":"(7,0 – 600) μg/m3"},{"name":"Range","range":"(0,0010 – 0,100) mg w próbce"}],"search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration/Content: Gas chromatography with flame ionization detection (GC-FID) acrylonitrile Range Range benzene Range Range buta-1,3-diene Range Range butan-1-ol (butyl alcohol) Range Range vinyl chloride Range Range chlorobenzene Range Range cyclohexane Range Range cyclohexanone Range Range ethylbenzene Range Range phenol Range Range formaldehyde Range Range EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","parameters_zh":[{"name":"akrylonitryl"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"苯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"buta-1,3-dien"},{"name":"范围","range":"(9,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0012 – 0,60) mg w próbce"},{"name":"butan-1-ol (alkohol butylowy)"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"氯乙烯"},{"name":"范围","range":"(4,9 – 4000) μg/m3"},{"name":"范围","range":"(0,0007 – 0,70) mg w próbce"},{"name":"氯苯"},{"name":"范围","range":"(3,2 – 4000) μg/m3"},{"name":"范围","range":"(0,0016 – 6,20) mg w próbce"},{"name":"环己烷"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"环己酮"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"乙苯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"苯酚"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,50) mg w próbce"},{"name":"甲醛"},{"name":"范围","range":"(7,0 – 600) μg/m3"},{"name":"范围","range":"(0,0010 – 0,100) mg w próbce"}],"search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 苯 范围 范围 范围 范围 范围 范围 氯乙烯 范围 范围 氯苯 范围 范围 环己烷 范围 范围 环己酮 范围 范围 乙苯 范围 范围 苯酚 范围 范围 甲醛 范围 范围 EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"浓度/含量：","test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4830","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie/Zawartość:","parameters":[{"name":"glikol etylenowy"},{"name":"Zakres","range":"(13,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0065 – 3,20) mg w próbce"},{"name":"krezole - mieszanina izomerów"},{"name":"Zakres","range":"(3,6 – 875) μg/m3"},{"name":"Zakres","range":"(0,0017 – 0,42) mg w próbce"},{"name":"ksylen – mieszanina izomerów"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 8,00) mg w próbce"},{"name":"octan butylu"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"octan etylu"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"octan winylu"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"styren"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"toluen"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 4,00) mg w próbce"},{"name":"trichloroeten"},{"name":"Zakres","range":"(2,0 – 4000) μg/m3"},{"name":"Zakres","range":"(0,0010 – 8,20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/Zawartość:\nZakres:\nglikol etylenowy\nZakres (13,0 – 4000) μg/m3\nZakres (0,0065 – 3,20) mg w próbce\nkrezole - mieszanina izomerów\nZakres (3,6 – 875) μg/m3\nZakres (0,0017 – 0,42) mg w próbce\nksylen – mieszanina izomerów\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,00) mg w próbce\noctan butylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\noctan etylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\noctan winylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nstyren\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ntoluen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ntrichloroeten\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","norm_bases":["EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Stężenie/Zawartość:\nZakres:\nglikol etylenowy\nZakres (13,0 – 4000) μg/m3\nZakres (0,0065 – 3,20) mg w próbce\nkrezole - mieszanina izomerów\nZakres (3,6 – 875) μg/m3\nZakres (0,0017 – 0,42) mg w próbce\nksylen – mieszanina izomerów\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,00) mg w próbce\noctan butylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\noctan etylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\noctan winylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\nstyren\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ntoluen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w próbce\ntrichloroeten\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Stezenie/Zawartosc:\nZakres:\nglikol etylenowy\nZakres (13,0 – 4000) μg/m3\nZakres (0,0065 – 3,20) mg w probce\nkrezole - mieszanina izomerow\nZakres (3,6 – 875) μg/m3\nZakres (0,0017 – 0,42) mg w probce\nksylen – mieszanina izomerow\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,00) mg w probce\noctan butylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\noctan etylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\noctan winylu\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\nstyren\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\ntoluen\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 4,00) mg w probce\ntrichloroeten\nZakres (2,0 – 4000) μg/m3\nZakres (0,0010 – 8,20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","categories":["environment"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/Content:","parameters_en":[{"name":"ethylene glycol"},{"name":"Range","range":"(13,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0065 – 3,20) mg w próbce"},{"name":"krezole - mieszanina izomerów"},{"name":"Range","range":"(3,6 – 875) μg/m3"},{"name":"Range","range":"(0,0017 – 0,42) mg w próbce"},{"name":"xylene – mixture of isomers"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 8,00) mg w próbce"},{"name":"butyl acetate"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"ethyl acetate"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"vinyl acetate"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"styrene"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"toluene"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 4,00) mg w próbce"},{"name":"trichloroethene"},{"name":"Range","range":"(2,0 – 4000) μg/m3"},{"name":"Range","range":"(0,0010 – 8,20) mg w próbce"}],"search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration/Content: Gas chromatography with flame ionization detection (GC-FID) ethylene glycol Range Range Range Range xylene – mixture of isomers Range Range butyl acetate Range Range ethyl acetate Range Range vinyl acetate Range Range styrene Range Range toluene Range Range trichloroethene Range Range EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","parameters_zh":[{"name":"glikol etylenowy"},{"name":"范围","range":"(13,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0065 – 3,20) mg w próbce"},{"name":"krezole - mieszanina izomerów"},{"name":"范围","range":"(3,6 – 875) μg/m3"},{"name":"范围","range":"(0,0017 – 0,42) mg w próbce"},{"name":"二甲苯 － 异构体混合物"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 8,00) mg w próbce"},{"name":"乙酸丁酯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"乙酸乙酯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"乙酸乙烯酯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"苯乙烯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"甲苯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 4,00) mg w próbce"},{"name":"三氯乙烯"},{"name":"范围","range":"(2,0 – 4000) μg/m3"},{"name":"范围","range":"(0,0010 – 8,20) mg w próbce"}],"search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 二甲苯 － 异构体混合物 范围 范围 乙酸丁酯 范围 范围 乙酸乙酯 范围 范围 乙酸乙烯酯 范围 范围 苯乙烯 范围 范围 甲苯 范围 范围 三氯乙烯 范围 范围 EV-PB-13 wydanie 1 z dnia 03.01.2023 r. EV-PB-14 wydanie 2 z dnia 28.03.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"浓度/含量：","test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品"},{"_id":"6a82eafc884ede9a1b2c4831","lab_id":"69ad52a3de79e566650fb8a3","country":"PL","accr_number":"AB 1642","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: − powietrze − próbki powietrza pobrane do worka z tworzywa sztucznego","methodology":"Stężenie tlenku diazotu (podtlenku azotu)","parameters":[{"name":"Zakres","range":"(3,7 – 3660) mg/m3"},{"name":"Zakres","range":"(2,0 – 1999,2) ppm"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","norm_bases":["EV-PB-18 wydanie 2 z dnia 13.01.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: − powietrze − próbki powietrza pobrane do worka z tworzywa sztucznego Stężenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) EV-PB-18 wydanie 2 z dnia 13.01.2026 r. Pomieszczenia przeznaczone na pobyt ludzi: − powietrze − probki powietrza pobrane do worka z tworzywa sztucznego Stezenie tlenku diazotu (podtlenku azotu)\nZakres:\nZakres (3,7 – 3660) mg/m3\nZakres (2,0 – 1999,2) ppm\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","categories":["materials","environment"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3,7 – 3660) mg/m3"},{"name":"Range","range":"(2,0 – 1999,2) ppm"}],"search_en":"Rooms intended for human occupancy: − air − air samples collected into a plastic bag Fourier transform infrared spectrometry (FT-IR) Range Range EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Rooms intended for human occupancy: − air − air samples collected into a plastic bag","parameters_zh":[{"name":"范围","range":"(3,7 – 3660) mg/m3"},{"name":"范围","range":"(2,0 – 1999,2) ppm"}],"search_zh":"傅里叶变换红外光谱法（FT-IR） 范围 范围 EV-PB-18 wydanie 2 z dnia 13.01.2026 r.","technique_zh":"傅里叶变换红外光谱法（FT-IR）"}],"has_pdf":true}