{"lab":{"_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","address":"ul. Chmielewskiego 13, 70-028 Szczecin","categories":["construction","water"],"city":"Szczecin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":56,"name":"BETOTEST POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1641.pdf"],"scope_summary":"","search_text":"betotest polska sp. z o.o. ul. chmielewskiego 13, 70-028 szczecin construction other materials water electronics","status":"active","updated_at":"2026-03-08T14:50:46.531Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:08:20.116Z","email_confidence":"high","email_mx":true,"email_source":"https://betotest.pl/kontakt/","parse_date":"2026-08-17T11:08:20.116Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne oraz pobieranie próbek wyrobów budowlanych","en":"Mechanical tests and sampling of building products"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów, materiałów i obiektów budowlanych","en":"Mechanical tests of building products,materials and items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych oraz pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Tests of physical properties and sampling of building products,materials and items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów, materiałów budowlanych","en":"Tests of physical properties of building products and materials"},{"codes":null,"pl":"Przedmiot badań/wyrób / Rodzaj działalności/badane cechy/metoda / Dokumenty odniesienia","en":null}],"issue":{"no":"12","date":"25.05.2026"},"map_coord":[53.405386,14.533991],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Szczecin","address":"ul. Chmielewskiego 13, 70-028 Szczecin","city":"Szczecin","postal":"70-028"},{"name":"Laboratorium Świnoujście","address":"ul. Jana Sołtana 1, 72-600 Świnoujście","city":"Świnoujście","postal":"72-600"},{"name":"Laboratorium Koszalin","address":"ul. Władysława IV 139b, 75-345 Koszalin","city":"Koszalin","postal":"75-345"},{"name":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Koszalin; (stacjonarna działalność techniczna)","address":null,"city":null,"postal":null},{"name":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","address":null,"city":null,"postal":null},{"name":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Świnoujście; (stacjonarna działalność techniczna)","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/7d286a157401c5f6ef779946dff9c99f/AB%201641.pdf","has_en":true,"category_counts":{"construction":27,"other":27,"water":6},"category_scores":{"construction":12.15,"other":12.15,"water":0.6},"has_zh":true},"methods":[{"_id":"6a82eba4884ede9a1b2c48cb","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a82eba4884ede9a1b2c48cc","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a82eba4884ede9a1b2c48cd","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda stolika rozpływowego","techniques":["Metoda stolika rozpływowego"],"computed":[],"activity":"Konsystencja\nMetoda stolika rozpływowego","reference":"PN-EN 12350-5:2019-08","norm_bases":["PN-EN 12350-5:2019-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda stolika rozpływowego PN-EN 12350-5:2019-08 Mieszanka betonowa Konsystencja\nMetoda stolika rozplywowego PN-EN 12350-5:2019-08","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Flow table method PN-EN 12350-5:2019-08","technique_en":"Flow table method","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 跳桌法 PN-EN 12350-5:2019-08","test_object_zh":"混凝土拌合物","technique_zh":"跳桌法"},{"_id":"6a82eba4884ede9a1b2c48ce","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0 - 10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nZakres (0 - 10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air content","parameters_en":[{"name":"Range","range":"(0 - 10) %"}],"search_en":"Fresh concrete Air content Pressure gauge method Range PN-EN 12350-7:2019-08","technique_en":"Pressure gauge method","test_object_en":"Fresh concrete","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"(0 - 10) %"}],"search_zh":"混凝土拌合物 含气量 压力计法 范围 PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物"},{"_id":"6a82eba4884ede9a1b2c48cf","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Concrete in structures Sampling PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48d0","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p.8.8","norm_bases":["PN-EN 932-1:1999 p.8.8"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p.8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p.8.8","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Aggregates Sampling PN-EN 932-1:1999 p.8.8","test_object_en":"Aggregates","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999 p.8.8","test_object_zh":"骨料"},{"_id":"6a82eba4884ede9a1b2c48d1","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p.8.8","norm_bases":["PN-EN 932-1:1999 p.8.8"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Pobieranie próbek PN-EN 932-1:1999 p.8.8 Grunty Pobieranie probek PN-EN 932-1:1999 p.8.8","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Ground Sampling PN-EN 932-1:1999 p.8.8","test_object_en":"Ground","methodology_zh":"样品采集","search_zh":"土体 样品采集 PN-EN 932-1:1999 p.8.8","test_object_zh":"土体"},{"_id":"6a82eba4884ede9a1b2c48d2","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Stopień zagęszczenia (ld)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p.6 Grunty Stopien zageszczenia (ld)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p.6","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compacting degree (ld)","search_en":"Ground Compacting degree (ld) Light probe with conical tip method PN-B-04452:2002 p.6","technique_en":"Light probe with conical tip method","test_object_en":"Ground","search_zh":"土体 轻型圆锥头触探仪法 PN-B-04452:2002 p.6","test_object_zh":"土体","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a82eba4884ede9a1b2c48d3","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Podłoże","methodology":"Moduł odkształcenia","parameters":[],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Moduł odkształcenia\nMetoda obciążeń płytą VSS PN-S 02205:1998 Podloze Modul odksztalcenia\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Deformation modulus","search_en":"Growing medium Deformation modulus VSS plate loading method PN-S 02205:1998","technique_en":"VSS plate loading method","test_object_en":"Growing medium","search_zh":"栽培基质 变形模量 VSS 平板荷载法 PN-S 02205:1998","test_object_zh":"栽培基质","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a82eba4884ede9a1b2c48d4","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Podłoże","methodology":"Dynamiczny moduł odkształcenia","parameters":[{"name":"Zakres","range":"(15 - 70) MN/m2"}],"technique":"Metoda lekką płytą dynamiczną","techniques":["Metoda lekką płytą dynamiczną"],"computed":[],"activity":"Dynamiczny moduł odkształcenia\nZakres (15 - 70) MN/m2\nMetoda lekką płytą dynamiczną","reference":"PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r.","norm_bases":["PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Dynamiczny moduł odkształcenia\nZakres (15 - 70) MN/m2\nMetoda lekką płytą dynamiczną PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r. Podloze Dynamiczny modul odksztalcenia\nZakres (15 - 70) MN/m2\nMetoda lekka plyta dynamiczna PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r.","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dynamic deformation modulus","parameters_en":[{"name":"Range","range":"(15 - 70) MN/m2"}],"search_en":"Growing medium Dynamic deformation modulus Light dynamic plate method Range PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r.","technique_en":"Light dynamic plate method","test_object_en":"Growing medium","parameters_zh":[{"name":"范围","range":"(15 - 70) MN/m2"}],"search_zh":"栽培基质 动态变形模量 范围 PB-PD/PQ7.2 wydanie 1 z dnia 20.01.2020 r.","test_object_zh":"栽培基质","methodology_zh":"动态变形模量"},{"_id":"6a82eba4884ede9a1b2c48d5","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Podłoże","methodology":"Stopień zagęszczenia (ld)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p.6 Podloze Stopien zageszczenia (ld)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p.6","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compacting degree (ld)","search_en":"Growing medium Compacting degree (ld) Light probe with conical tip method PN-B-04452:2002 p.6","technique_en":"Light probe with conical tip method","test_object_en":"Growing medium","search_zh":"栽培基质 轻型圆锥头触探仪法 PN-B-04452:2002 p.6","test_object_zh":"栽培基质","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a82eba4884ede9a1b2c48d6","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres","range":"(0,02-0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres (0,02-0,45) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres (0,02-0,45) MPa\nMetoda obciążeń płytą VSS PN-S 02205:1998 Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres (0,02-0,45) MPa\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Deformation modulus","parameters_en":[{"name":"Range","range":"(0,02-0,45) MPa"}],"search_en":"Pavement structural layers Deformation modulus VSS plate loading method Range PN-S 02205:1998","technique_en":"VSS plate loading method","test_object_en":"Pavement structural layers","parameters_zh":[{"name":"范围","range":"(0,02-0,45) MPa"}],"search_zh":"路面结构层 变形模量 VSS 平板荷载法 范围 PN-S 02205:1998","test_object_zh":"路面结构层","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a82eba4884ede9a1b2c48d7","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych","methodology":"Wytrzymałość na odrywanie","parameters":[{"name":"Zakres","range":"(1 - 16) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"computed":[],"activity":"Wytrzymałość na odrywanie\nZakres (1 - 16) kN\nMetoda pull-off","reference":"PN-EN 1542:2000","norm_bases":["PN-EN 1542:2000"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymałość na odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN 1542:2000 Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymalosc na odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN 1542:2000","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pull-off strength","parameters_en":[{"name":"Range","range":"(1 - 16) kN"}],"search_en":"Products and systems for the protection and repair of concrete structures Pull-off strength Pull-off method Range PN-EN 1542:2000","technique_en":"Pull-off method","test_object_en":"Products and systems for the protection and repair of concrete structures","parameters_zh":[{"name":"范围","range":"(1 - 16) kN"}],"search_zh":"混凝土结构防护与修复制品与系统 拉拔强度 拉拔法 范围 PN-EN 1542:2000","technique_zh":"拉拔法","test_object_zh":"混凝土结构防护与修复制品与系统","methodology_zh":"拉拔强度"},{"_id":"6a82eba4884ede9a1b2c48d8","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12697-27:2017-07 p.4.7","norm_bases":["PN-EN 12697-27:2017-07 p.4.7"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Pobieranie próbek PN-EN 12697-27:2017-07 p.4.7 Nawierzchnie drogowe (asfaltowe) Pobieranie probek PN-EN 12697-27:2017-07 p.4.7","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Road pavements (asphalt) Sampling PN-EN 12697-27:2017-07 p.4.7","test_object_en":"Road pavements (asphalt)","methodology_zh":"样品采集","search_zh":"路面（沥青） 样品采集 PN-EN 12697-27:2017-07 p.4.7","test_object_zh":"路面（沥青）"},{"_id":"6a82eba4884ede9a1b2c48d9","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(150 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (150 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (150 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (150 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(150 - 3000) kN"}],"search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(150 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48da","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","search_en":"Concrete Density PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48db","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(10 - 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (10 - 100) kN","reference":"PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2019-08"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres (10 - 100) kN PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres (10 - 100) kN PN-EN 12390-5:2019-08","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flexural strength","parameters_en":[{"name":"Range","range":"(10 - 100) kN"}],"search_en":"Concrete Flexural strength Range PN-EN 12390-5:2019-08","test_object_en":"Concrete","parameters_zh":[{"name":"范围","range":"(10 - 100) kN"}],"search_zh":"混凝土 抗弯强度 范围 PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度"},{"_id":"6a82eba4884ede9a1b2c48dc","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres","range":"(100 - 600) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (100 - 600) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (100 - 600) kN PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (100 - 600) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Range","range":"(100 - 600) kN"}],"search_en":"Concrete Splitting tensile strength Range PN-EN 12390-6:2024-04","test_object_en":"Concrete","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(100 - 600) kN"}],"search_zh":"混凝土 劈裂抗拉强度 范围 PN-EN 12390-6:2024-04","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48dd","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete Depth of penetration of water under pressure PN-EN 12390-8:2019-08","test_object_en":"Concrete","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48de","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu w obecności soli odladzającej","parameters":[],"technique":"Metoda slab test","techniques":["Metoda slab test"],"computed":[],"activity":"Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test","reference":"PKN-CEN/TS 12390-9:2007 | PKN-CEN/TS 12390-9:2017-07","norm_bases":["PKN-CEN/TS 12390-9:2007","PKN-CEN/TS 12390-9:2017-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test PKN-CEN/TS 12390-9:2007 | PKN-CEN/TS 12390-9:2017-07 Beton Odpornosc na dzialanie mrozu w obecnosci soli odladzajacej\nMetoda slab test PKN-CEN/TS 12390-9:2007 | PKN-CEN/TS 12390-9:2017-07","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Concrete PKN-CEN/TS 12390-9:2007 | PKN-CEN/TS 12390-9:2017-07","test_object_en":"Concrete","search_zh":"混凝土 PKN-CEN/TS 12390-9:2007 | PKN-CEN/TS 12390-9:2017-07","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48df","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete Water absorption PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48e0","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability","search_en":"Concrete Water permeability PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48e1","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250 | PN-B-06265:2018-10 Zał.N | PN-B-06265:2022-08 Zał.N","norm_bases":["PN-88/B-06250","PN-B-06265:2018-10 Zał.N","PN-B-06265:2022-08 Zał.N"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 | PN-B-06265:2018-10 Zał.N | PN-B-06265:2022-08 Zał.N Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250 | PN-B-06265:2018-10 Zal.N | PN-B-06265:2022-08 Zal.N","categories":["construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing Ordinary method PN-88/B-06250 | PN-B-06265:2018-10 Zał.N | PN-B-06265:2022-08 Zał.N","technique_en":"Ordinary method","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-88/B-06250 | PN-B-06265:2018-10 Zał.N | PN-B-06265:2022-08 Zał.N","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a82eba4884ede9a1b2c48e2","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(20 - 3000)kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (20 - 3000)kN","reference":"PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12504-1:2019-08","PN-EN 12390-3:2019-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres (20 - 3000)kN PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07 Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres (20 - 3000)kN PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(20 - 3000)kN"}],"search_en":"Concrete in structures Compressive strength Range PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","test_object_en":"Concrete in structures","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(20 - 3000)kN"}],"search_zh":"结构中的混凝土 抗压强度 范围 PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e3","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton w konstrukcjach Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","search_en":"Concrete in structures Density Method of determining sample volume from dimensions PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","technique_en":"Method of determining sample volume from dimensions","test_object_en":"Concrete in structures","methodology_zh":"密度","search_zh":"结构中的混凝土 密度 PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e4","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton w konstrukcjach Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete in structures Depth of penetration of water under pressure PN-EN 12390-8:2019-08","test_object_en":"Concrete in structures","methodology_zh":"压力水渗透深度","search_zh":"结构中的混凝土 压力水渗透深度 PN-EN 12390-8:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e5","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Nasiąkliwość PN-88/B-06250 Beton w konstrukcjach Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete in structures Water absorption PN-88/B-06250","test_object_en":"Concrete in structures","methodology_zh":"吸水率","search_zh":"结构中的混凝土 吸水率 PN-88/B-06250","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e6","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Przepuszczalność wody PN-88/B-06250 Beton w konstrukcjach Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability","search_en":"Concrete in structures Water permeability PN-88/B-06250","test_object_en":"Concrete in structures","methodology_zh":"透水性","search_zh":"结构中的混凝土 透水性 PN-88/B-06250","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e7","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250 | PN-B-06265:2022-08 Zał. N","norm_bases":["PN-88/B-06250","PN-B-06265:2022-08 Zał. N"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 | PN-B-06265:2022-08 Zał. N Beton w konstrukcjach Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250 | PN-B-06265:2022-08 Zal. N","categories":["construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to freezing","search_en":"Concrete in structures Resistance to freezing Ordinary method PN-88/B-06250 | PN-B-06265:2022-08 Zał. N","technique_en":"Ordinary method","test_object_en":"Concrete in structures","methodology_zh":"抗冻性","search_zh":"结构中的混凝土 抗冻性 常规法 PN-88/B-06250 | PN-B-06265:2022-08 Zał. N","technique_zh":"常规法","test_object_zh":"结构中的混凝土"},{"_id":"6a82eba4884ede9a1b2c48e8","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 - 63) mm"}],"search_en":"Aggregates Particle size distribution Sieving method Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,063 - 63) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a82eba4884ede9a1b2c48e9","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust content","search_en":"Aggregates Dust content Sieving method PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","search_zh":"骨料 粉尘含量 筛分法 PN-EN 933-1:2012","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"粉尘含量"},{"_id":"6a82eba4884ede9a1b2c48ea","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik kształtu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik kształtu","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik kształtu PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu PN-EN 933-4:2008","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shape index","search_en":"Aggregates Shape index PN-EN 933-4:2008","test_object_en":"Aggregates","search_zh":"骨料 形状指数 PN-EN 933-4:2008","test_object_zh":"骨料","methodology_zh":"形状指数"},{"_id":"6a82eba4884ede9a1b2c48eb","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn o powierzchni przekruszonej lub łamanej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn o powierzchni przekruszonej lub łamanej","reference":"PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","norm_bases":["PN-EN 933-5:2000","PN-EN 933-5:2000/A1:2005"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn o powierzchni przekruszonej lub łamanej PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005 Kruszywa Zawartosc ziarn o powierzchni przekruszonej lub lamanej PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of grains with crushed or broken surfaces","search_en":"Aggregates Content of grains with crushed or broken surfaces PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","test_object_en":"Aggregates","search_zh":"骨料 PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","test_object_zh":"骨料"},{"_id":"6a82eba4884ede9a1b2c48ec","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn przekruszonych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn przekruszonych","reference":"PN-EN 933-5:2023-05","norm_bases":["PN-EN 933-5:2023-05"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn przekruszonych PN-EN 933-5:2023-05 Kruszywa Zawartosc ziarn przekruszonych PN-EN 933-5:2023-05","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of crushed particles","search_en":"Aggregates Content of crushed particles PN-EN 933-5:2023-05","test_object_en":"Aggregates","search_zh":"骨料 压碎颗粒含量 PN-EN 933-5:2023-05","test_object_zh":"骨料","methodology_zh":"压碎颗粒含量"},{"_id":"6a82eba4884ede9a1b2c48ed","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sand equivalent value","search_en":"Aggregates Sand equivalent value PN-EN 933-8+A1:2015-07","test_object_en":"Aggregates","search_zh":"骨料 砂当量 PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","methodology_zh":"砂当量"},{"_id":"6a82eba4884ede9a1b2c48ee","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość nasypowa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa","reference":"PN-EN 1097-3:2000 z wył. Zał. A","norm_bases":["PN-EN 1097-3:2000 z wył. Zał. A"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość nasypowa PN-EN 1097-3:2000 z wył. Zał. A Kruszywa Gestosc nasypowa PN-EN 1097-3:2000 z wyl. Zal. A","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","search_en":"Aggregates Bulk density PN-EN 1097-3:2000 z wył. Zał. A","test_object_en":"Aggregates","search_zh":"骨料 堆积密度 PN-EN 1097-3:2000 z wył. Zał. A","test_object_zh":"骨料","methodology_zh":"堆积密度"},{"_id":"6a82eba4884ede9a1b2c48ef","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nMetoda wagowa","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość wody\nMetoda wagowa PN-EN 1097-5:2008 Kruszywa Zawartosc wody\nMetoda wagowa PN-EN 1097-5:2008","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","search_en":"Aggregates Water content Gravimetric method PN-EN 1097-5:2008","technique_en":"Gravimetric method","test_object_en":"Aggregates","methodology_zh":"水分含量","search_zh":"骨料 水分含量 重量法 PN-EN 1097-5:2008","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a82eba4884ede9a1b2c48f0","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość ziarn i nasiąkliwość","parameters":[],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość ziarn i nasiąkliwość\nMetoda piknometryczna","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość ziarn i nasiąkliwość\nMetoda piknometryczna PN-EN 1097-6:2022-07 Kruszywa Gestosc ziarn i nasiakliwosc\nMetoda piknometryczna PN-EN 1097-6:2022-07","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle density and water absorption","search_en":"Aggregates Particle density and water absorption Pycnometric method PN-EN 1097-6:2022-07","technique_en":"Pycnometric method","test_object_en":"Aggregates","search_zh":"骨料 颗粒密度与吸水率 比重瓶法 PN-EN 1097-6:2022-07","test_object_zh":"骨料","technique_zh":"比重瓶法","methodology_zh":"颗粒密度与吸水率"},{"_id":"6a82eba4884ede9a1b2c48f1","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kruszywa","methodology":"Kalifornijski wskaźnik nośności CBR","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalifornijski wskaźnik nośności CBR","reference":"PN-EN 13286-47:2022-04","norm_bases":["PN-EN 13286-47:2022-04"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Kalifornijski wskaźnik nośności CBR PN-EN 13286-47:2022-04 Kruszywa Kalifornijski wskaznik nosnosci CBR PN-EN 13286-47:2022-04","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"California Bearing Ratio CBR","search_en":"Aggregates California Bearing Ratio CBR PN-EN 13286-47:2022-04","test_object_en":"Aggregates","search_zh":"骨料 加州承载比 CBR PN-EN 13286-47:2022-04","test_object_zh":"骨料","methodology_zh":"加州承载比 CBR"},{"_id":"6a82eba4884ede9a1b2c48f2","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym (Kruszywa)","methodology":"Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu\nMetoda Proctora","reference":"PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","norm_bases":["PN-EN 13286-2:2010","PN-EN 13286-2:2010/AC:2014-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym (Kruszywa) Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu\nMetoda Proctora PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07 Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym (Kruszywa) Optymalna zawartosc wody oraz maksymalna gestosc objetosciowa szkieletu\nMetoda Proctora PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Optimum water content and maximum bulk density of the skeleton","search_en":"Unbound and hydraulically bound mixtures (Aggregates) Optimum water content and maximum bulk density of the skeleton Proctor method PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","technique_en":"Proctor method","test_object_en":"Unbound and hydraulically bound mixtures (Aggregates)","search_zh":"未结合与水硬性胶结料结合的混合料（集料） 普氏击实法 PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","technique_zh":"普氏击实法","test_object_zh":"未结合与水硬性胶结料结合的混合料（集料）"},{"_id":"6a82eba4884ede9a1b2c48f3","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Kamień naturalny","methodology":"Wytrzymałość na jednoosiowe ściskanie","parameters":[{"name":"Zakres","range":"(4 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na jednoosiowe ściskanie\nZakres (4 – 3000) kN","reference":"PN-EN 1926:2007","norm_bases":["PN-EN 1926:2007"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamień naturalny Wytrzymałość na jednoosiowe ściskanie\nZakres (4 – 3000) kN PN-EN 1926:2007 Kamien naturalny Wytrzymalosc na jednoosiowe sciskanie\nZakres (4 – 3000) kN PN-EN 1926:2007","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Uniaxial compressive strength","parameters_en":[{"name":"Range","range":"(4 – 3000) kN"}],"search_en":"Natural stone Uniaxial compressive strength Range PN-EN 1926:2007","test_object_en":"Natural stone","parameters_zh":[{"name":"范围","range":"(4 – 3000) kN"}],"search_zh":"天然石材 范围 PN-EN 1926:2007","test_object_zh":"天然石材"},{"_id":"6a82eba4884ede9a1b2c48f4","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa","parameters":[{"name":"Zakres","range":"(0,063 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa\nZakres (0,063 - 40) mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1 Grunty Analiza sitowa\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sieve analysis","parameters_en":[{"name":"Range","range":"(0,063 - 40) mm"}],"search_en":"Ground Sieve analysis Range PN-88/B-04481 p.4.1","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,063 - 40) mm"}],"search_zh":"土体 筛分分析 范围 PN-88/B-04481 p.4.1","test_object_zh":"土体","methodology_zh":"筛分分析"},{"_id":"6a82eba4884ede9a1b2c48f5","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji <0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji <0,063 mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji <0,063 mm PN-88/B-04481 p.4.1 Grunty Zawartosc frakcji <0,063 mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of the <0,063 mm fraction","search_en":"Ground Content of the <0,063 mm fraction PN-88/B-04481 p.4.1","test_object_en":"Ground","search_zh":"土体 PN-88/B-04481 p.4.1","test_object_zh":"土体"},{"_id":"6a82eba4884ede9a1b2c48f6","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność\nMetoda wagowa","reference":"PN-88/B-04481 p.5.1","norm_bases":["PN-88/B-04481 p.5.1"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność\nMetoda wagowa PN-88/B-04481 p.5.1 Grunty Wilgotnosc\nMetoda wagowa PN-88/B-04481 p.5.1","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Humidity","search_en":"Ground Humidity Gravimetric method PN-88/B-04481 p.5.1","technique_en":"Gravimetric method","test_object_en":"Ground","search_zh":"土体 湿度 重量法 PN-88/B-04481 p.5.1","technique_zh":"重量法","test_object_zh":"土体","methodology_zh":"湿度"},{"_id":"6a82eba4884ede9a1b2c48f7","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora (metoda I i II)","techniques":["Metoda Proctora (metoda I i II)"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II)","reference":"PN-88/B-04481 p.8","norm_bases":["PN-88/B-04481 p.8"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8 Grunty Wilgotnosc optymalna, Maksymalna gestosc objetosciowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Ground Optimum moisture content, Maximum dry density of the soil skeleton Proctor method (method I and II) PN-88/B-04481 p.8","technique_en":"Proctor method (method I and II)","test_object_en":"Ground","search_zh":"土体 最佳含水率、土骨架最大干密度 普氏击实法（方法 I 与 II） PN-88/B-04481 p.8","test_object_zh":"土体","methodology_zh":"最佳含水率、土骨架最大干密度","technique_zh":"普氏击实法（方法 I 与 II）"},{"_id":"6a82eba4884ede9a1b2c48f8","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik nośności gruntu wnoś","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności gruntu wnoś","reference":"PN-S-02205:1998","norm_bases":["PN-S-02205:1998"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik nośności gruntu wnoś PN-S-02205:1998 Grunty Wskaznik nosnosci gruntu wnos PN-S-02205:1998","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Ground PN-S-02205:1998","test_object_en":"Ground","search_zh":"土体 PN-S-02205:1998","test_object_zh":"土体"},{"_id":"6a82eba4884ede9a1b2c48f9","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik zagęszczenia (Is)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (Is)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6","PN-77/8931-12 p.4"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik zagęszczenia (Is)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4 Grunty Wskaznik zageszczenia (Is)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compaction index (Is)","search_en":"Ground Compaction index (Is) Driven cylinder method PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Ground","search_zh":"土体 压实指数（Is） 压入圆筒法 PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","test_object_zh":"土体","technique_zh":"压入圆筒法","methodology_zh":"压实指数（Is）"},{"_id":"6a82eba4884ede9a1b2c48fa","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunt stabilizowany cementem","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(1 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 - 50) kN","reference":"PN-S-96012:1997","norm_bases":["PN-S-96012:1997"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunt stabilizowany cementem Wytrzymałość na ściskanie\nZakres (1 - 50) kN PN-S-96012:1997 Grunt stabilizowany cementem Wytrzymalosc na sciskanie\nZakres (1 - 50) kN PN-S-96012:1997","categories":["construction"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(1 - 50) kN"}],"search_en":"Cement-stabilized soil Compressive strength Range PN-S-96012:1997","test_object_en":"Cement-stabilized soil","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 - 50) kN"}],"search_zh":"水泥稳定土 抗压强度 范围 PN-S-96012:1997","test_object_zh":"水泥稳定土"},{"_id":"6a82eba4884ede9a1b2c48fb","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Mieszanki związane spoiwem hydraulicznym","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(2 - 600) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (2 - 600) kN","reference":"PN-EN 13286-41:2022-04","norm_bases":["PN-EN 13286-41:2022-04"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki związane spoiwem hydraulicznym Wytrzymałość na ściskanie\nZakres (2 - 600) kN PN-EN 13286-41:2022-04 Mieszanki zwiazane spoiwem hydraulicznym Wytrzymalosc na sciskanie\nZakres (2 - 600) kN PN-EN 13286-41:2022-04","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(2 - 600) kN"}],"search_en":"Hydraulically bound mixtures Compressive strength Range PN-EN 13286-41:2022-04","test_object_en":"Hydraulically bound mixtures","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(2 - 600) kN"}],"search_zh":"水硬性胶结料结合的混合料 抗压强度 范围 PN-EN 13286-41:2022-04","test_object_zh":"水硬性胶结料结合的混合料"},{"_id":"6a82eba4884ede9a1b2c48fc","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Podłoże","methodology":"Wskaźnik zagęszczenia (Is)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (Is)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6","PN-77/8931-12 p.4"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Wskaźnik zagęszczenia (Is)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4 Podloze Wskaznik zageszczenia (Is)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compaction index (Is)","search_en":"Growing medium Compaction index (Is) Driven cylinder method PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Growing medium","search_zh":"栽培基质 压实指数（Is） 压入圆筒法 PN-88/B-04481 p.5.2.6 | PN-77/8931-12 p.4","test_object_zh":"栽培基质","technique_zh":"压入圆筒法","methodology_zh":"压实指数（Is）"},{"_id":"6a82eba4884ede9a1b2c48fd","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Grubość warstwy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Grubość warstwy","reference":"PN-EN 12697-36:2022-09 p. 6.1","norm_bases":["PN-EN 12697-36:2022-09 p. 6.1"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Szczecin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Grubość warstwy PN-EN 12697-36:2022-09 p. 6.1 Nawierzchnie drogowe (asfaltowe) Grubosc warstwy PN-EN 12697-36:2022-09 p. 6.1","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Layer thickness","search_en":"Road pavements (asphalt) Layer thickness PN-EN 12697-36:2022-09 p. 6.1","test_object_en":"Road pavements (asphalt)","search_zh":"路面（沥青） 层厚 PN-EN 12697-36:2022-09 p. 6.1","test_object_zh":"路面（沥青）","methodology_zh":"层厚"},{"_id":"6a82eba4884ede9a1b2c48fe","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Świnoujście; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(100 - 3000) kN"}],"search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c48ff","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Świnoujście; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","search_en":"Concrete Density Method of determining sample volume from dimensions PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","technique_en":"Method of determining sample volume from dimensions","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c4900","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 - 2000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 2000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Koszalin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 - 2000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 - 2000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(100 - 2000) kN"}],"search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 2000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c4901","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Koszalin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","search_en":"Concrete Density Method of determining sample volume from dimensions PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","technique_en":"Method of determining sample volume from dimensions","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a82eba4884ede9a1b2c4902","lab_id":"69ad52a3de79e566650fb8a1","country":"PL","accr_number":"AB 1641","accr_body":"PCA","test_object":"Grunt stabilizowany cementem","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(2 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (2 - 50) kN","reference":"PN-S-96012:1997","norm_bases":["PN-S-96012:1997"],"lab_section":"BETOTEST POLSKA Sp. z o.o.; Laboratorium Koszalin; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunt stabilizowany cementem Wytrzymałość na ściskanie\nZakres (2 - 50) kN PN-S-96012:1997 Grunt stabilizowany cementem Wytrzymalosc na sciskanie\nZakres (2 - 50) kN PN-S-96012:1997","categories":["construction"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(2 - 50) kN"}],"search_en":"Cement-stabilized soil Compressive strength Range PN-S-96012:1997","test_object_en":"Cement-stabilized soil","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(2 - 50) kN"}],"search_zh":"水泥稳定土 抗压强度 范围 PN-S-96012:1997","test_object_zh":"水泥稳定土"}],"has_pdf":true}