{"lab":{"_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","address":"LABORATORIUM INŻYNIERII CIEPLNEJ, ul. Warszawska 24, 31-155 Kraków","categories":["construction","water"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1632.pdf"],"scope_summary":"","search_text":"politechnika krakowska im. tadeusza kościuszki laboratorium inżynierii cieplnej, ul. warszawska 24, 31-155 kraków construction other metrology water materials automotive","status":"active","updated_at":"2026-03-08T14:50:46.050Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:46.050Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201632,plik.html","parse_date":"2026-07-17T16:19:16.719Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"A/5","pl":"Badania akustyczne wyrobów budowlanych, obiektów budowlanych","en":"Acoustic tests of building products, building items"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych, obiektów budowlanych","en":"Mechanical tests of building products, building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych, obiektów budowlanych","en":"Tests of physical properties of building products, building items"}],"issue":{"no":"11","date":"19.11.2025"},"map_coord":[50.071547,19.943933],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":29,"construction":3,"water":2,"environment":1},"category_scores":{"other":24.03,"construction":0.26,"water":0.11,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a5a56049af9f73f382548cf","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna, drzwi, okna dachowe, okna lub świetliki wystające poza lico przegród","test_object_en":"Windows, doors, roof windows, windows or rooflights projecting beyond the face of building envelopes","methodology":"Współczynnik przenikania ciepła Metoda obliczeniowa","methodology_en":"Thermal transmittance Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda obliczeniowa","reference":"PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N”","norm_bases":["PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna, drzwi, okna dachowe, okna lub świetliki wystające poza lico przegród Współczynnik przenikania ciepła Metoda obliczeniowa PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” Okna, drzwi, okna dachowe, okna lub swietliki wystajace poza lico przegrod Wspolczynnik przenikania ciepla Metoda obliczeniowa PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N”","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows, doors, roof windows, windows or rooflights projecting beyond the face of building envelopes Thermal transmittance Calculation method PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N”","methodology_zh":"传热系数 计算法","search_zh":"传热系数 计算法 PN-EN ISO 10077-1:2017 “N” PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N”"},{"_id":"6a5a56049af9f73f382548d0","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Sekcje ram okien, drzwi, ich połączenia z oszkleniem, żaluzje, skrzynki żaluzji","test_object_en":"Sections of window and door frames, their connections with glazing, shutters, shutter boxes","methodology":"Współczynnik przenikania ciepła Metoda obliczeniowa","methodology_en":"Thermal transmittance Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda obliczeniowa","reference":"PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017","norm_bases":["PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sekcje ram okien, drzwi, ich połączenia z oszkleniem, żaluzje, skrzynki żaluzji Współczynnik przenikania ciepła Metoda obliczeniowa PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017 Sekcje ram okien, drzwi, ich polaczenia z oszkleniem, zaluzje, skrzynki zaluzji Wspolczynnik przenikania ciepla Metoda obliczeniowa PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sections of window and door frames, their connections with glazing, shutters, shutter boxes Thermal transmittance Calculation method PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017","methodology_zh":"传热系数 计算法","search_zh":"传热系数 计算法 PN-EN ISO 10077-2:2017- 10/A1:2025-06 “N” PN-EN ISO 10211:2017"},{"_id":"6a5a56049af9f73f382548d1","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Ściany osłonowe","test_object_en":"Curtain walling","methodology":"Współczynnik przenikania ciepła Metoda obliczeniowa","methodology_en":"Thermal transmittance Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda obliczeniowa","reference":"PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017","norm_bases":["PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Współczynnik przenikania ciepła Metoda obliczeniowa PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017 Sciany oslonowe Wspolczynnik przenikania ciepla Metoda obliczeniowa PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Thermal transmittance Calculation method PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017","methodology_zh":"传热系数 计算法","search_zh":"幕墙 传热系数 计算法 PN-EN ISO 12631:2017 PN-EN ISO 6946:2017 PN-EN ISO 10211:2017","test_object_zh":"幕墙"},{"_id":"6a5a56049af9f73f382548d2","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Oszklenia","test_object_en":"Glazing","methodology":"Współczynnik przenikania ciepła Metoda obliczeniowa","methodology_en":"Thermal transmittance Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda obliczeniowa","reference":"PN-EN 673:2025-05 “N”","norm_bases":["PN-EN 673:2025-05 “N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oszklenia Współczynnik przenikania ciepła Metoda obliczeniowa PN-EN 673:2025-05 “N” Oszklenia Wspolczynnik przenikania ciepla Metoda obliczeniowa PN-EN 673:2025-05 “N”","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glazing Thermal transmittance Calculation method PN-EN 673:2025-05 “N”","methodology_zh":"传热系数 计算法","search_zh":"传热系数 计算法 PN-EN 673:2025-05 “N”"},{"_id":"6a5a56049af9f73f382548d3","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna, drzwi Wymiary obiektów do 1,50 m x 1,50 m","test_object_en":"Windows, doors Dimensions of items up to 1,50 m x 1,50 m","methodology":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","methodology_en":"Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","reference":"PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998","norm_bases":["PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna, drzwi Wymiary obiektów do 1,50 m x 1,50 m Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998 Okna, drzwi Wymiary obiektow do 1,50 m x 1,50 m Wspolczynnik przenikania ciepla Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows, doors Dimensions of items up to 1,50 m x 1,50 m Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k) PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998","methodology_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k)","search_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k) PN-EN ISO 12567-1:2010+AC:2010 “N” PN-EN ISO 8990:1998"},{"_id":"6a5a56049af9f73f382548d4","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna dachowe i inne okna wystające z płaszczyzny Wymiary obiektów do 1,50 m x 1,50 m","test_object_en":"Roof windows and other windows projecting from the plane Dimensions of items up to 1,50 m x 1,50 m","methodology":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","methodology_en":"Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","reference":"PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998","norm_bases":["PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna dachowe i inne okna wystające z płaszczyzny Wymiary obiektów do 1,50 m x 1,50 m Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998 Okna dachowe i inne okna wystajace z plaszczyzny Wymiary obiektow do 1,50 m x 1,50 m Wspolczynnik przenikania ciepla Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roof windows and other windows projecting from the plane Dimensions of items up to 1,50 m x 1,50 m Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k) PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998","methodology_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k)","search_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k) PN-EN ISO 12567-2:2006 “N” PN-EN ISO 8990:1998"},{"_id":"6a5a56049af9f73f382548d5","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Ramy Wymiary obiektów do 1,50 m x 1,50 m","test_object_en":"Frames Dimensions of objects up to 1,50 m x 1,50 m","methodology":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","methodology_en":"Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k)","reference":"PN-EN 12412-2:2005 PN-EN ISO 8990:1998","norm_bases":["PN-EN 12412-2:2005 PN-EN ISO 8990:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ramy Wymiary obiektów do 1,50 m x 1,50 m Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998 Ramy Wymiary obiektow do 1,50 m x 1,50 m Wspolczynnik przenikania ciepla Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 3 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Frames Dimensions of objects up to 1,50 m x 1,50 m Thermal transmittance Hot box method, U range from 0,15 W/(m2k) to 3 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998","methodology_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k)","search_zh":"传热系数 热箱法，U 范围 0,15 W/(m2k) 至 3 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998"},{"_id":"6a5a56049af9f73f382548d6","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Skrzynki żaluzji zwijanych Wymiary obiektów do 1,50 m x 1,50 m","test_object_en":"Roller shutter boxes Dimensions of objects up to 1,50 m x 1,50 m","methodology":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 4 W/(m2k)","methodology_en":"Thermal transmittance Hot box method, Range U from 0,15 W/(m2k) to 4 W/(m2k)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 4 W/(m2k)","reference":"PN-EN 12412-2:2005 PN-EN ISO 8990:1998","norm_bases":["PN-EN 12412-2:2005 PN-EN ISO 8990:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skrzynki żaluzji zwijanych Wymiary obiektów do 1,50 m x 1,50 m Współczynnik przenikania ciepła Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 4 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998 Skrzynki zaluzji zwijanych Wymiary obiektow do 1,50 m x 1,50 m Wspolczynnik przenikania ciepla Metoda skrzynki grzejnej, Zakres U od 0,15 W/(m2k) do 4 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roller shutter boxes Dimensions of objects up to 1,50 m x 1,50 m Thermal transmittance Hot box method, Range U from 0,15 W/(m2k) to 4 W/(m2k) PN-EN 12412-2:2005 PN-EN ISO 8990:1998"},{"_id":"6a5a56049af9f73f382548d7","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające","test_object_en":"Terminal ventilation devices Control and shut-off dampers","methodology":"Szczelność przepustnic Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","methodology_en":"Tightness of dampers Air flow measurement method Range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność przepustnic Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 1751:2024-10 PN-EN 13053:2020","norm_bases":["PN-EN 1751:2024-10 PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające Szczelność przepustnic Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020 Urzadzenia wentylacyjne koncowe Przepustnice regulacyjne i zamykajace Szczelnosc przepustnic Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Terminal ventilation devices Control and shut-off dampers Tightness of dampers Air flow measurement method Range: from 0,18 m3/h to 1100 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020","search_zh":"末端通风装置；调节与关断风阀 PN-EN 1751:2024-10 PN-EN 13053:2020","test_object_zh":"末端通风装置；调节与关断风阀"},{"_id":"6a5a56049af9f73f382548d8","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające","test_object_en":"Terminal ventilation devices Control and shut-off dampers","methodology":"Badanie mechaniczne przepustnic regulacyjnych i zamykających Metoda pomiaru momentu obrotowego na trzpieniu przepustnicy Zakres: od 0,2 Nm do 20 Nm","methodology_en":"Mechanical testing of control and shut-off dampers Method of measuring the torque on the damper spindle Range: from 0,2 Nm to 20 Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie mechaniczne przepustnic regulacyjnych i zamykających Metoda pomiaru momentu obrotowego na trzpieniu przepustnicy Zakres: od 0,2 Nm do 20 Nm","reference":"PN-EN 1751:2024-10 PN-EN 13053:2020","norm_bases":["PN-EN 1751:2024-10 PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające Badanie mechaniczne przepustnic regulacyjnych i zamykających Metoda pomiaru momentu obrotowego na trzpieniu przepustnicy Zakres: od 0,2 Nm do 20 Nm PN-EN 1751:2024-10 PN-EN 13053:2020 Urzadzenia wentylacyjne koncowe Przepustnice regulacyjne i zamykajace Badanie mechaniczne przepustnic regulacyjnych i zamykajacych Metoda pomiaru momentu obrotowego na trzpieniu przepustnicy Zakres: od 0,2 Nm do 20 Nm PN-EN 1751:2024-10 PN-EN 13053:2020","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Terminal ventilation devices Control and shut-off dampers Mechanical testing of control and shut-off dampers Method of measuring the torque on the damper spindle Range: from 0,2 Nm to 20 Nm PN-EN 1751:2024-10 PN-EN 13053:2020","search_zh":"末端通风装置；调节与关断风阀 PN-EN 1751:2024-10 PN-EN 13053:2020","test_object_zh":"末端通风装置；调节与关断风阀"},{"_id":"6a5a56049af9f73f382548d9","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające","test_object_en":"Terminal ventilation devices Control and shut-off dampers","methodology":"Aerodynamiczna charakterystyka przepustnicy Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h","methodology_en":"Aerodynamic characteristics of the damper Air flow measurement method Range: from 1 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Aerodynamiczna charakterystyka przepustnicy Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h","reference":"PN-EN 1751:2024-10 PN-EN 13053:2020","norm_bases":["PN-EN 1751:2024-10 PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wentylacyjne końcowe Przepustnice regulacyjne i zamykające Aerodynamiczna charakterystyka przepustnicy Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020 Urzadzenia wentylacyjne koncowe Przepustnice regulacyjne i zamykajace Aerodynamiczna charakterystyka przepustnicy Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Terminal ventilation devices Control and shut-off dampers Aerodynamic characteristics of the damper Air flow measurement method Range: from 1 m3/h to 18000 m3/h PN-EN 1751:2024-10 PN-EN 13053:2020","search_zh":"末端通风装置；调节与关断风阀 PN-EN 1751:2024-10 PN-EN 13053:2020","test_object_zh":"末端通风装置；调节与关断风阀"},{"_id":"6a5a56049af9f73f382548da","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody wentylacyjne z blachy o przekroju prostokątnym","test_object_en":"Sheet metal ventilation ducts of rectangular cross-section","methodology":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","methodology_en":"Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 1507:2007","norm_bases":["PN-EN 1507:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne z blachy o przekroju prostokątnym Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 1507:2007 Przewody wentylacyjne z blachy o przekroju prostokatnym Szczelnosc przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 1507:2007","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sheet metal ventilation ducts of rectangular cross-section Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h PN-EN 1507:2007","methodology_zh":"风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h","search_zh":"风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h PN-EN 1507:2007"},{"_id":"6a5a56049af9f73f382548db","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody wentylacyjne z blachy o przekroju kołowym","test_object_en":"Sheet metal ventilation ducts of circular cross-section","methodology":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","methodology_en":"Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 12237:2005","norm_bases":["PN-EN 12237:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne z blachy o przekroju kołowym Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 12237:2005 Przewody wentylacyjne z blachy o przekroju kolowym Szczelnosc przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 12237:2005","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sheet metal ventilation ducts of circular cross-section Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h PN-EN 12237:2005","methodology_zh":"风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h","search_zh":"风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h PN-EN 12237:2005"},{"_id":"6a5a56049af9f73f382548dc","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody wentylacyjne niemetalowe","test_object_en":"Non-metallic ventilation ducts","methodology":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","methodology_en":"Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 17192:2019","norm_bases":["PN-EN 17192:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne niemetalowe Szczelność przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 17192:2019 Przewody wentylacyjne niemetalowe Szczelnosc przewodu Metoda pomiaru strumienia powietrza Zakres: od 0,18 m3/h do 1100 m3/h PN-EN 17192:2019","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic ventilation ducts Duct tightness Air flow rate measurement method Range: from 0,18 m3/h to 1100 m3/h PN-EN 17192:2019","methodology_zh":"风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h","search_zh":"非金属通风风管 风管密封性 空气流量测量法 范围：0,18 m3/h 至 1100 m3/h PN-EN 17192:2019","test_object_zh":"非金属通风风管"},{"_id":"6a5a56049af9f73f382548dd","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody wentylacyjne niemetalowe","test_object_en":"Non-metallic ventilation ducts","methodology":"Spadek ciśnienia Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h","methodology_en":"Pressure drop Air flow measurement method Range: from 1 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Spadek ciśnienia Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h","reference":"PN-EN 17192:2019","norm_bases":["PN-EN 17192:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne niemetalowe Spadek ciśnienia Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h PN-EN 17192:2019 Przewody wentylacyjne niemetalowe Spadek cisnienia Metoda pomiaru strumienia powietrza Zakres: od 1 m3/h do 18000 m3/h PN-EN 17192:2019","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic ventilation ducts Pressure drop Air flow measurement method Range: from 1 m3/h to 18000 m3/h PN-EN 17192:2019","search_zh":"非金属通风风管 PN-EN 17192:2019","test_object_zh":"非金属通风风管"},{"_id":"6a5a56049af9f73f382548de","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna i drzwi","test_object_en":"Windows and doors","methodology":"Przepuszczalność powietrza Metoda pomiaru strumienia powietrza Zakres: 0,18 m3/h do 1100 m3/h","methodology_en":"Air permeability Air flow measurement method Range: 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza Metoda pomiaru strumienia powietrza Zakres: 0,18 m3/h do 1100 m3/h","reference":"PN-EN 1026:2016 „N”","norm_bases":["PN-EN 1026:2016 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna i drzwi Przepuszczalność powietrza Metoda pomiaru strumienia powietrza Zakres: 0,18 m3/h do 1100 m3/h PN-EN 1026:2016 „N” Okna i drzwi Przepuszczalnosc powietrza Metoda pomiaru strumienia powietrza Zakres: 0,18 m3/h do 1100 m3/h PN-EN 1026:2016 „N”","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows and doors Air permeability Air flow measurement method Range: 0,18 m3/h to 1100 m3/h PN-EN 1026:2016 „N”","search_zh":"窗与门 PN-EN 1026:2016 „N”","test_object_zh":"窗与门"},{"_id":"6a5a56049af9f73f382548df","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna, drzwi Wymiary obiektów do 2,00 x 2,50 m","test_object_en":"Windows, doors Dimensions of items up to 2,00 x 2,50 m","methodology":"Uderzenie ciałem miękkim i ciężkim Metoda wahadła udarowego o masie 50 kg Zakres wzniosu wahadła do 2,0 m","methodology_en":"Soft and heavy body impact Impact pendulum method with a mass of 50 kg Pendulum drop height range up to 2,0 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Uderzenie ciałem miękkim i ciężkim Metoda wahadła udarowego o masie 50 kg Zakres wzniosu wahadła do 2,0 m","reference":"PN-EN 13049:2023","norm_bases":["PN-EN 13049:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna, drzwi Wymiary obiektów do 2,00 x 2,50 m Uderzenie ciałem miękkim i ciężkim Metoda wahadła udarowego o masie 50 kg Zakres wzniosu wahadła do 2,0 m PN-EN 13049:2023 Okna, drzwi Wymiary obiektow do 2,00 x 2,50 m Uderzenie cialem miekkim i ciezkim Metoda wahadla udarowego o masie 50 kg Zakres wzniosu wahadla do 2,0 m PN-EN 13049:2023","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows, doors Dimensions of items up to 2,00 x 2,50 m Soft and heavy body impact Impact pendulum method with a mass of 50 kg Pendulum drop height range up to 2,0 m PN-EN 13049:2023"},{"_id":"6a5a56049af9f73f382548e0","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Okna, drzwi Wymiary obiektów do 1,50 x 1,50 m","test_object_en":"Windows, doors Dimensions of items up to 1,50 x 1,50 m","methodology":"Wodoszczelność Metoda badania penetracji wody Zakres natrysku wody od 1 l/(min dyszę) do 2 l/(min dyszę) Ciśnienie naporu do 2500 Pa","methodology_en":"Watertightness Water penetration test method Water spray rate from 1 l/(min nozzle) to 2 l/(min nozzle) Applied pressure up to 2500 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Metoda badania penetracji wody Zakres natrysku wody od 1 l/(min dyszę) do 2 l/(min dyszę) Ciśnienie naporu do 2500 Pa","reference":"PN-EN 1027-2016","norm_bases":["PN-EN 1027-2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna, drzwi Wymiary obiektów do 1,50 x 1,50 m Wodoszczelność Metoda badania penetracji wody Zakres natrysku wody od 1 l/(min dyszę) do 2 l/(min dyszę) Ciśnienie naporu do 2500 Pa PN-EN 1027-2016 Okna, drzwi Wymiary obiektow do 1,50 x 1,50 m Wodoszczelnosc Metoda badania penetracji wody Zakres natrysku wody od 1 l/(min dysze) do 2 l/(min dysze) Cisnienie naporu do 2500 Pa PN-EN 1027-2016","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows, doors Dimensions of items up to 1,50 x 1,50 m Watertightness Water penetration test method Water spray rate from 1 l/(min nozzle) to 2 l/(min nozzle) Applied pressure up to 2500 Pa PN-EN 1027-2016"},{"_id":"6a5a56049af9f73f382548e1","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Mechaniczna wytrzymałość obudowy Zakres ciśnienia próbnego: do 3000 Pa","methodology_en":"Mechanical strength of the enclosure Test pressure range: up to 3000 Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mechaniczna wytrzymałość obudowy Zakres ciśnienia próbnego: do 3000 Pa","reference":"PN-EN 1886:2008","norm_bases":["PN-EN 1886:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Mechaniczna wytrzymałość obudowy Zakres ciśnienia próbnego: do 3000 Pa PN-EN 1886:2008 Centrale wentylacyjne i klimatyzacyjne Mechaniczna wytrzymalosc obudowy Zakres cisnienia probnego: do 3000 Pa PN-EN 1886:2008","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Mechanical strength of the enclosure Test pressure range: up to 3000 Pa PN-EN 1886:2008","search_zh":"通风与空调机组 PN-EN 1886:2008","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e2","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Szczelność obudowy Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h","methodology_en":"Enclosure tightness Air flow measurement method Air leakage range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność obudowy Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 1886:2008 PN-EN 13053:2020","norm_bases":["PN-EN 1886:2008 PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Szczelność obudowy Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Szczelnosc obudowy Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Enclosure tightness Air flow measurement method Air leakage range: from 0,18 m3/h to 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 1886:2008 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e3","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Szczelność montażu filtrów Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h","methodology_en":"Tightness of filter installation Air flow measurement method Air leakage range: from 0,18 m3/h to 1100 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność montażu filtrów Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h","reference":"PN-EN 1886:2008 PN-EN 13053:2020","norm_bases":["PN-EN 1886:2008 PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Szczelność montażu filtrów Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Szczelnosc montazu filtrow Metoda pomiaru strumienia powietrza Zakres przecieku powietrza: od 0,18 m3/h do 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Tightness of filter installation Air flow measurement method Air leakage range: from 0,18 m3/h to 1100 m3/h PN-EN 1886:2008 PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 1886:2008 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e4","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Właściwości cieplne obudowy Zakres U od 0,15 W/(m2K) do 6 W/(m2K)","methodology_en":"Thermal properties of the enclosure Range U from 0,15 W/(m2K) to 6 W/(m2K)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości cieplne obudowy Zakres U od 0,15 W/(m2K) do 6 W/(m2K)","reference":"PN-EN 1886:2008","norm_bases":["PN-EN 1886:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Właściwości cieplne obudowy Zakres U od 0,15 W/(m2K) do 6 W/(m2K) PN-EN 1886:2008 Centrale wentylacyjne i klimatyzacyjne Wlasciwosci cieplne obudowy Zakres U od 0,15 W/(m2K) do 6 W/(m2K) PN-EN 1886:2008","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Thermal properties of the enclosure Range U from 0,15 W/(m2K) to 6 W/(m2K) PN-EN 1886:2008","search_zh":"通风与空调机组 PN-EN 1886:2008","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e5","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Izolacyjność akustyczna obudowy Zakres tłumienia hałasu Dp od 5,0 dB do 70,0 dB","methodology_en":"Sound insulation of the enclosure Noise attenuation range Dp from 5,0 dB to 70,0 dB","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna obudowy Zakres tłumienia hałasu Dp od 5,0 dB do 70,0 dB","reference":"PN-EN 1886:2008","norm_bases":["PN-EN 1886:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Izolacyjność akustyczna obudowy Zakres tłumienia hałasu Dp od 5,0 dB do 70,0 dB PN-EN 1886:2008 Centrale wentylacyjne i klimatyzacyjne Izolacyjnosc akustyczna obudowy Zakres tlumienia halasu Dp od 5,0 dB do 70,0 dB PN-EN 1886:2008","categories":["environment","construction"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Sound insulation of the enclosure Noise attenuation range Dp from 5,0 dB to 70,0 dB PN-EN 1886:2008","search_zh":"通风与空调机组 PN-EN 1886:2008","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e6","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Bezpieczeństwo mechaniczne","methodology_en":"Mechanical safety","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bezpieczeństwo mechaniczne","reference":"PN-EN 1886:2008","norm_bases":["PN-EN 1886:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Bezpieczeństwo mechaniczne PN-EN 1886:2008 Centrale wentylacyjne i klimatyzacyjne Bezpieczenstwo mechaniczne PN-EN 1886:2008","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Mechanical safety PN-EN 1886:2008","search_zh":"通风与空调机组 PN-EN 1886:2008","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e7","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Aerodynamiczna charakterystyka centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","methodology_en":"Aerodynamic characteristics of the air handling unit Air flow range of the unit: from 200 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Aerodynamiczna charakterystyka centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","reference":"PN-EN 13053:2020","norm_bases":["PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Aerodynamiczna charakterystyka centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Aerodynamiczna charakterystyka centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Aerodynamic characteristics of the air handling unit Air flow range of the unit: from 200 m3/h to 18000 m3/h PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e8","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Sekcja odzysku ciepła / sprawność odzysku ciepła Zakres strumienia powietrza sekcji: od 200 m3/h do 3000 m3/h","methodology_en":"Heat recovery section / heat recovery efficiency Air flow range of the section: from 200 m3/h to 3000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sekcja odzysku ciepła / sprawność odzysku ciepła Zakres strumienia powietrza sekcji: od 200 m3/h do 3000 m3/h","reference":"PN-EN 13053:2020","norm_bases":["PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Sekcja odzysku ciepła / sprawność odzysku ciepła Zakres strumienia powietrza sekcji: od 200 m3/h do 3000 m3/h PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Sekcja odzysku ciepla / sprawnosc odzysku ciepla Zakres strumienia powietrza sekcji: od 200 m3/h do 3000 m3/h PN-EN 13053:2020","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Heat recovery section / heat recovery efficiency Air flow range of the section: from 200 m3/h to 3000 m3/h PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548e9","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Średnia prędkość powietrza w obudowie Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","methodology_en":"Average air velocity in the enclosure Range of the air handling unit air flow: from 200 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnia prędkość powietrza w obudowie Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","reference":"PN-EN 13053:2020","norm_bases":["PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Średnia prędkość powietrza w obudowie Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Srednia predkosc powietrza w obudowie Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Average air velocity in the enclosure Range of the air handling unit air flow: from 200 m3/h to 18000 m3/h PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548ea","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Centrale wentylacyjne i klimatyzacyjne","test_object_en":"Ventilation and air conditioning units","methodology":"Moc napędowa wentylatora w centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","methodology_en":"Fan drive power in the air handling unit Air flow range of the unit: from 200 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc napędowa wentylatora w centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h","reference":"PN-EN 13053:2020","norm_bases":["PN-EN 13053:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Centrale wentylacyjne i klimatyzacyjne Moc napędowa wentylatora w centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020 Centrale wentylacyjne i klimatyzacyjne Moc napedowa wentylatora w centrali Zakres strumienia powietrza centrali: od 200 m3/h do 18000 m3/h PN-EN 13053:2020","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ventilation and air conditioning units Fan drive power in the air handling unit Air flow range of the unit: from 200 m3/h to 18000 m3/h PN-EN 13053:2020","search_zh":"通风与空调机组 PN-EN 13053:2020","test_object_zh":"通风与空调机组"},{"_id":"6a5a56049af9f73f382548eb","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Urządzenia wentylacyjne końcowe Kraty żaluzjowe","test_object_en":"Air terminal devices Louvre grilles","methodology":"Aerodynamiczna charakterystyka kraty Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h","methodology_en":"Aerodynamic characteristics of the grille Air flow range: from 200 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Aerodynamiczna charakterystyka kraty Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h","reference":"PN-EN 13030:2002","norm_bases":["PN-EN 13030:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wentylacyjne końcowe Kraty żaluzjowe Aerodynamiczna charakterystyka kraty Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h PN-EN 13030:2002 Urzadzenia wentylacyjne koncowe Kraty zaluzjowe Aerodynamiczna charakterystyka kraty Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h PN-EN 13030:2002","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Air terminal devices Louvre grilles Aerodynamic characteristics of the grille Air flow range: from 200 m3/h to 18000 m3/h PN-EN 13030:2002"},{"_id":"6a5a56049af9f73f382548ec","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Urządzenia wentylacyjne końcowe Kraty żaluzjowe","test_object_en":"Air terminal devices Louvre grilles","methodology":"Przenikanie wody opadowej Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h","methodology_en":"Rainwater penetration Air flow range: from 200 m3/h to 18000 m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenikanie wody opadowej Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h","reference":"PN-EN 13030:2002","norm_bases":["PN-EN 13030:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia wentylacyjne końcowe Kraty żaluzjowe Przenikanie wody opadowej Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h PN-EN 13030:2002 Urzadzenia wentylacyjne koncowe Kraty zaluzjowe Przenikanie wody opadowej Zakres strumienia powietrza: od 200 m3/h do 18000 m3/h PN-EN 13030:2002","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Air terminal devices Louvre grilles Rainwater penetration Air flow range: from 200 m3/h to 18000 m3/h PN-EN 13030:2002"},{"_id":"6a5a56049af9f73f382548ed","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody proste i kształtki wentylacyjne o przekroju prostokątnym","test_object_en":"Straight ventilation ducts and fittings of rectangular cross-section","methodology":"Wymiary Zakres wymiaru: od 10 mm do 5000 mm","methodology_en":"Dimensions Dimension range: from 10 mm to 5000 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary Zakres wymiaru: od 10 mm do 5000 mm","reference":"PN-EN 1505:2001","norm_bases":["PN-EN 1505:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody proste i kształtki wentylacyjne o przekroju prostokątnym Wymiary Zakres wymiaru: od 10 mm do 5000 mm PN-EN 1505:2001 Przewody proste i ksztaltki wentylacyjne o przekroju prostokatnym Wymiary Zakres wymiaru: od 10 mm do 5000 mm PN-EN 1505:2001","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Straight ventilation ducts and fittings of rectangular cross-section Dimensions Dimension range: from 10 mm to 5000 mm PN-EN 1505:2001"},{"_id":"6a5a56049af9f73f382548ee","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody proste i kształtki wentylacyjne o przekroju kołowym","test_object_en":"Straight ventilation ducts and fittings of circular cross-section","methodology":"Wymiary Zakres wymiaru: od 10 mm do 5000 mm","methodology_en":"Dimensions Dimension range: from 10 mm to 5000 mm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary Zakres wymiaru: od 10 mm do 5000 mm","reference":"PN-EN 1506:2007","norm_bases":["PN-EN 1506:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody proste i kształtki wentylacyjne o przekroju kołowym Wymiary Zakres wymiaru: od 10 mm do 5000 mm PN-EN 1506:2007 Przewody proste i ksztaltki wentylacyjne o przekroju kolowym Wymiary Zakres wymiaru: od 10 mm do 5000 mm PN-EN 1506:2007","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Straight ventilation ducts and fittings of circular cross-section Dimensions Dimension range: from 10 mm to 5000 mm PN-EN 1506:2007"},{"_id":"6a5a56049af9f73f382548ef","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Oszklenia","test_object_en":"Glazing","methodology":"Właściwości świetlne i słoneczne Metoda obliczeniowa","methodology_en":"Light and solar properties Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości świetlne i słoneczne Metoda obliczeniowa","reference":"PN-EN 410:2011 „N”","norm_bases":["PN-EN 410:2011 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Oszklenia Właściwości świetlne i słoneczne Metoda obliczeniowa PN-EN 410:2011 „N” Oszklenia Wlasciwosci swietlne i sloneczne Metoda obliczeniowa PN-EN 410:2011 „N”","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Glazing Light and solar properties Calculation method PN-EN 410:2011 „N”"},{"_id":"6a5a56049af9f73f382548f0","lab_id":"69ad52a3de79e566650fb895","country":"PL","accr_number":"AB 1632","accr_body":"PCA","test_object":"Przewody wentylacyjne niemetalowe","test_object_en":"Non-metallic ventilation ducts","methodology":"Opór cieplny Metoda obliczeniowa","methodology_en":"Thermal resistance Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór cieplny Metoda obliczeniowa","reference":"Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r.","norm_bases":["Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody wentylacyjne niemetalowe Opór cieplny Metoda obliczeniowa Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r. Przewody wentylacyjne niemetalowe Opor cieplny Metoda obliczeniowa Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r.","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Non-metallic ventilation ducts Thermal resistance Calculation method Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r.","search_zh":"非金属通风风管 Procedura Badawcza PB 12 wydanie 1 z 13.01.2023 r.","test_object_zh":"非金属通风风管"}],"has_pdf":true}