{"lab":{"_id":"69ad52a3de79e566650fb891","accr_number":"AB 1630","country":"PL","accr_body":"PCA","address":"Urbański, Pawelak, ul. Jasna 1, 00-013 Warszawa","categories":["environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"Laboratorium EMVO Spółka Jawna","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1630.pdf"],"scope_summary":"","search_text":"laboratorium emvo spółka jawna urbański, pawelak, ul. jasna 1, 00-013 warszawa environment metrology pharma electronics other","status":"active","updated_at":"2026-03-08T14:50:45.874Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:00:35.589Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201630,podmiot.html","parse_date":"2026-08-17T11:00:35.589Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"20","date":"29.06.2026"},"map_coord":[52.233743,21.012018],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak","address":"ul. Jasna 1, 00-013 Warszawa","city":"Warszawa","postal":"00-013"},{"name":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak","address":"ul. Mostowa 1, 80-778 Gdańsk","city":"Gdańsk","postal":"80-778"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/fb6d3ec8add792d7a5f69068def37da5/AB%201630.pdf","has_en":true,"category_counts":{"environment":15},"category_scores":{"environment":15},"has_zh":true},"methods":[{"_id":"6a82e9d3884ede9a1b2c45e1","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 27 MHz do 90 GHz"},{"name":"Zakres","range":"(0,8 – 260) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 27 MHz do 90 GHz"},{"name":"Range","range":"(0,8 – 260) V/m"}],"search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Electric field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 27 MHz do 90 GHz"},{"name":"范围","range":"(0,8 – 260) V/m"}],"search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场 电场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场"},{"_id":"6a82e9d3884ede9a1b2c45e2","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 27 MHz do 1 GHz"},{"name":"Zakres","range":"(0,01 – 14) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 27 MHz do 1 GHz"},{"name":"Range","range":"(0,01 – 14) A/m"}],"search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 27 MHz do 1 GHz"},{"name":"范围","range":"(0,01 – 14) A/m"}],"search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场 磁场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场"},{"_id":"6a82e9d3884ede9a1b2c45e3","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 90 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 800 MHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 90 GHz"}],"search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength: (calculated) in the frequency range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"(calculated)","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 90 GHz"}],"search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场 磁场强度： （计算得出） 频率范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"（计算得出）","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场"},{"_id":"6a82e9d3884ede9a1b2c45e4","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 41 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii *) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 41 kV/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Electric field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 41 kV/m"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *) 电场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45e5","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *)","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"1 µT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *) Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii *) Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"1 µT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Magnetic flux density: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *)","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"1 µT – 19 mT"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *) 磁感应强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45e6","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii *) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii *) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Magnetic field strength: (calculated) in the frequency range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"(calculated)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *) 磁场强度： （计算得出） 频率范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_zh":"（计算得出）","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45e7","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne *)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 41 kV/m"},{"name":"w zakresie częstotliwości","range":"od 400 kHz do 27 MHz"},{"name":"Zakres","range":"(0,8 – 1000) V/m"},{"name":"w zakresie częstotliwości","range":"od 27 MHz do 90 GHz"},{"name":"Zakres","range":"(0,8 – 260) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nw zakresie częstotliwości od 400 kHz do 27 MHz\nZakres (0,8 – 1000) V/m\nw zakresie częstotliwości od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne *) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nw zakresie częstotliwości od 400 kHz do 27 MHz\nZakres (0,8 – 1000) V/m\nw zakresie częstotliwości od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pole elektromagnetyczne *) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 1 V/m – 41 kV/m\nw zakresie czestotliwosci od 400 kHz do 27 MHz\nZakres (0,8 – 1000) V/m\nw zakresie czestotliwosci od 27 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 41 kV/m"},{"name":"in the frequency range","range":"od 400 kHz do 27 MHz"},{"name":"Range","range":"(0,8 – 1000) V/m"},{"name":"in the frequency range","range":"od 27 MHz do 90 GHz"},{"name":"Range","range":"(0,8 – 260) V/m"}],"search_en":"Workplace environment – electromagnetic field *) Electric field strength: Direct measurement method in the frequency range Range in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field *)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 41 kV/m"},{"name":"频率范围","range":"od 400 kHz do 27 MHz"},{"name":"范围","range":"(0,8 – 1000) V/m"},{"name":"频率范围","range":"od 27 MHz do 90 GHz"},{"name":"范围","range":"(0,8 – 260) V/m"}],"search_zh":"工作环境 － 电磁场 *) 电场强度： 直接测量法 频率范围 范围 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45e8","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne *)","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"1 µT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne *) Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pole elektromagnetyczne *) Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 1 µT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"1 µT – 19 mT"}],"search_en":"Workplace environment – electromagnetic field *) Magnetic flux density: Direct measurement method in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field *)","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"1 µT – 19 mT"}],"search_zh":"工作环境 － 电磁场 *) 磁感应强度： 直接测量法 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45e9","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne *)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 400 kHz do 27 MHz"},{"name":"Zakres","range":"(0,012 – 16) A/m"},{"name":"w zakresie częstotliwości","range":"od 27 MHz do 1 GHz"},{"name":"Zakres","range":"(0,01 – 14) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 400 kHz do 27 MHz\nZakres (0,012 – 16) A/m\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne *) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 400 kHz do 27 MHz\nZakres (0,012 – 16) A/m\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pole elektromagnetyczne *) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 400 kHz do 27 MHz\nZakres (0,012 – 16) A/m\nw zakresie czestotliwosci od 27 MHz do 1 GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 400 kHz do 27 MHz"},{"name":"Range","range":"(0,012 – 16) A/m"},{"name":"in the frequency range","range":"od 27 MHz do 1 GHz"},{"name":"Range","range":"(0,01 – 14) A/m"}],"search_en":"Workplace environment – electromagnetic field *) Magnetic field strength: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field *)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 400 kHz do 27 MHz"},{"name":"范围","range":"(0,012 – 16) A/m"},{"name":"频率范围","range":"od 27 MHz do 1 GHz"},{"name":"范围","range":"(0,01 – 14) A/m"}],"search_zh":"工作环境 － 电磁场 *) 磁场强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45ea","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne *)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"w zakresie częstotliwości","range":"od 800 MHz do 90 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne *) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pole elektromagnetyczne *) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nw zakresie czestotliwosci od 800 MHz do 90 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"in the frequency range","range":"od 800 MHz do 90 GHz"}],"search_en":"Workplace environment – electromagnetic field *) Magnetic field strength: (calculated) in the frequency range in the frequency range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"(calculated)","test_object_en":"Workplace environment – electromagnetic field *)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"频率范围","range":"od 800 MHz do 90 GHz"}],"search_zh":"工作环境 － 电磁场 *) 磁场强度： （计算得出） 频率范围 频率范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"（计算得出）","test_object_zh":"工作环境 － 电磁场 *)"},{"_id":"6a82e9d3884ede9a1b2c45eb","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 MHz do 90 GHz"},{"name":"Zakres","range":"(0,8 – 260) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 90 GHz\nZakres (0,8 – 260) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 MHz do 90 GHz"},{"name":"Range","range":"(0,8 – 260) V/m"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 MHz do 90 GHz"},{"name":"范围","range":"(0,8 – 260) V/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82e9d3884ede9a1b2c45ec","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości:","range":"od 27 MHz do 1GHz"},{"name":"Zakres","range":"(0,01 – 14) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: od 27 MHz do 1GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: od 27 MHz do 1GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci: od 27 MHz do 1GHz\nZakres (0,01 – 14) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"w zakresie częstotliwości:","range":"od 27 MHz do 1GHz"},{"name":"Range","range":"(0,01 – 14) A/m"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości:","range":"od 27 MHz do 1GHz"},{"name":"范围","range":"(0,01 – 14) A/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82e9d3884ede9a1b2c45ed","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości:","range":"od 10 MHz do 90 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości: od 10 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nw zakresie częstotliwości: od 10 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nw zakresie czestotliwosci: od 10 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: (calculated) Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"(calculated)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"磁场强度：","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： （计算得出） Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"（计算得出）","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82e9d3884ede9a1b2c45ee","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości:","range":"od 420 MHz do 6 GHz"},{"name":"Zakres","range":"(0,1 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości: od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości: od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci: od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości:","range":"od 420 MHz do 6 GHz"},{"name":"Range","range":"(0,1 – 200) V/m"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości:","range":"od 420 MHz do 6 GHz"},{"name":"范围","range":"(0,1 – 200) V/m"}],"search_zh":"电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a82e9d3884ede9a1b2c45ef","lab_id":"69ad52a3de79e566650fb891","country":"PL","accr_number":"AB 1630","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 420 MHz do 6 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 420 MHz do 6 GHz\n(z obliczeń)","reference":"Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium EMVO Spółka Jawna Urbański, Pawelak, ul. Mostowa 1, 80-778 Gdańsk","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 420 MHz do 6 GHz\n(z obliczeń) Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 420 MHz do 6 GHz\n(z obliczen) Punkt 3 zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 420 MHz do 6 GHz"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength: (calculated) in the frequency range Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"(calculated)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 420 MHz do 6 GHz"}],"search_zh":"磁场强度： （计算得出） 频率范围 Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"（计算得出）"}],"has_pdf":true}