{"lab":{"_id":"69ad52a3de79e566650fb887","accr_number":"AB 1624","country":"PL","accr_body":"PCA","address":"ENERGOTHERM Sp. z o.o., LABORATORIUM BADAWCZE, ul. Poznańska 5, 62 – 081 Przeźmierowo","categories":["environment"],"city":"Przeźmierowo","imported_at":"2026-03-08T10:42:43.265Z","methods_count":100,"name":"Przedsiębiorstwo Badań i Analiz Energetycznych","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1624.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo badań i analiz energetycznych energotherm sp. z o.o., laboratorium badawcze, ul. poznańska 5, 62 – 081 przeźmierowo metrology environment other materials automotive food","status":"active","updated_at":"2026-03-08T14:50:45.449Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:57:33.040Z","email_confidence":"high","email_mx":true,"email_source":"https://energotherm.pl/contact/","parse_date":"2026-08-17T10:57:33.040Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne – maszyny i urządzenia","en":"Acoustic tests of machinery and devices"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33, G/34, G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe, hałas w środowisku pracy, hałas w środowisku ogólnym","en":"Tests concerning environmental engineering (environmental and climatic) - waste gases, noise in the workplace, noise at general environment"},{"codes":"M/13, M/58","pl":"Badania inne - QAL2 i AST automatycznych systemów monitoringu (AMS)","en":"Other tests - QAL2 and AST of automated measuring systems (AMS)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"16","date":"24.07.2026"},"map_coord":[52.434351,16.791397],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Poznańska 5","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/31098f1097d64413b81e28aeacbf4f1d/AB%201624.pdf","has_en":true,"category_counts":{"other":56,"environment":40,"materials":3,"metrology":2},"category_scores":{"other":31.05,"environment":15.84,"materials":0.09,"metrology":0.04},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Poznańska 5","city":null,"postal":null}]},"methods":[{"_id":"6a82e91d884ede9a1b2c4306","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa","parameters":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"computed":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07","norm_bases":["PN-EN ISO 16911-1:2013-07"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych > 5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Gas velocity and volume flow rate for differential pressures > 5 Pa","search_en":"Waste gases Gas velocity and volume flow rate for differential pressures > 5 Pa Differential pressure measurement method Testing Laboratory PN-EN ISO 16911-1:2013-07","technique_en":"Differential pressure measurement method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 压差 > 5 Pa 时的气体流速与体积流量 差压测量法 检测实验室 PN-EN ISO 16911-1:2013-07","test_object_zh":"废气","technique_zh":"差压测量法","methodology_zh":"压差 > 5 Pa 时的气体流速与体积流量"},{"_id":"6a82e91d884ede9a1b2c4307","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method Testing Laboratory PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 检测实验室 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a82e91d884ede9a1b2c4308","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration Testing Laboratory PN-Z-04030-7:1994","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘浓度测定采样 检测实验室 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c4309","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Testing Laboratory Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 检测实验室 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c430a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) Testing Laboratory PN-Z-04030-7:1994","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘排放量（计算值） 检测实验室 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c430b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration Testing Laboratory PN-EN 13284-1:2018-02","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘浓度测定采样 检测实验室 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c430c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,48 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,48 – 50) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Testing Laboratory Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,48 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 检测实验室 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c430d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) Testing Laboratory PN-EN 13284-1:2018-02","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘排放量（计算值） 检测实验室 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c430e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki","parameters":[{"name":"SO2","range":"(8,0 – 5100) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie dwutlenku siarki\nSO2 (8,0 – 5100) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 10396:2007 | PN-ISO 7935:2000","norm_bases":["ISO 10396:2007","PN-ISO 7935:2000"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki\nSO2 (8,0 – 5100) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007 | PN-ISO 7935:2000 Gazy odlotowe Stezenie dwutlenku siarki\nSO2 (8,0 – 5100) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007 | PN-ISO 7935:2000","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sulphur dioxide concentration","parameters_en":[{"name":"SO2","range":"(8,0 – 5100) mg/m3"}],"search_en":"Waste gases Sulphur dioxide concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory SO2 ISO 10396:2007 | PN-ISO 7935:2000","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 二氧化硫浓度 非分散红外光谱法（NDIR） 检测实验室 SO2 ISO 10396:2007 | PN-ISO 7935:2000","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","parameters_zh":[{"name":"SO2","range":"(8,0 – 5100) mg/m3"}],"methodology_zh":"二氧化硫浓度"},{"_id":"6a82e91d884ede9a1b2c430f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"ISO 10396:2007 | PN-ISO 7935:2000","norm_bases":["ISO 10396:2007","PN-ISO 7935:2000"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) ISO 10396:2007 | PN-ISO 7935:2000 Gazy odlotowe Emisja SO2 (z obliczen) ISO 10396:2007 | PN-ISO 7935:2000","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 emission (calculated)","search_en":"Waste gases SO2 emission (calculated) Testing Laboratory ISO 10396:2007 | PN-ISO 7935:2000","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 SO2 排放量（计算值） 检测实验室 ISO 10396:2007 | PN-ISO 7935:2000","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c4310","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017 | ISO 10396:2007","norm_bases":["PN-EN 14792:2017","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017 | ISO 10396:2007 Gazy odlotowe Stezenie tlenku azotu, dwutlenku azotu, tlenkow azotu\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017 | ISO 10396:2007","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides Chemiluminescence method Testing Laboratory NO NO2 NOx PN-EN 14792:2017 | ISO 10396:2007","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 化学发光法 检测实验室 NO NO2 NOx PN-EN 14792:2017 | ISO 10396:2007","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"technique_zh":"化学发光法"},{"_id":"6a82e91d884ede9a1b2c4311","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017 | ISO 10396:2007","norm_bases":["PN-EN 14792:2017","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017 | ISO 10396:2007 Gazy odlotowe Emisja NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017 | ISO 10396:2007","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Testing Laboratory PN-EN 14792:2017 | ISO 10396:2007","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN 14792:2017 | ISO 10396:2007","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4312","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku węgla","parameters":[{"name":"CO2","range":"(0,6 – 18) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie dwutlenku węgla\nCO2 (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019 | ISO 10396:2007","norm_bases":["ISO 12039:2019","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla\nCO2 (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 | ISO 10396:2007 Gazy odlotowe Stezenie dwutlenku wegla\nCO2 (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 | ISO 10396:2007","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"CO2","range":"(0,6 – 18) %"}],"search_en":"Waste gases Carbon dioxide concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory CO2 ISO 12039:2019 | ISO 10396:2007","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 二氧化碳浓度 非分散红外光谱法（NDIR） 检测实验室 CO2 ISO 12039:2019 | ISO 10396:2007","test_object_zh":"废气","parameters_zh":[{"name":"CO2","range":"(0,6 – 18) %"}],"technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"二氧化碳浓度"},{"_id":"6a82e91d884ede9a1b2c4313","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku węgla (z obliczeń)","reference":"ISO 12039:2019 | ISO 10396:2007","norm_bases":["ISO 12039:2019","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku węgla (z obliczeń) ISO 12039:2019 | ISO 10396:2007 Gazy odlotowe Emisja dwutlenku wegla (z obliczen) ISO 12039:2019 | ISO 10396:2007","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon dioxide emission (calculated)","search_en":"Waste gases Carbon dioxide emission (calculated) Testing Laboratory ISO 12039:2019 | ISO 10396:2007","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 二氧化碳排放（由计算得出） 检测实验室 ISO 12039:2019 | ISO 10396:2007","test_object_zh":"废气","methodology_zh":"二氧化碳排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4314","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla","parameters":[{"name":"CO","range":"(3,0 – 1200) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla\nCO (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017 | ISO 10396:2007","norm_bases":["PN-EN 15058:2017","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nCO (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017 | ISO 10396:2007 Gazy odlotowe Stezenie tlenku wegla\nCO (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017 | ISO 10396:2007","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"CO","range":"(3,0 – 1200) mg/m3"}],"search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory CO PN-EN 15058:2017 | ISO 10396:2007","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 检测实验室 CO PN-EN 15058:2017 | ISO 10396:2007","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","parameters_zh":[{"name":"CO","range":"(3,0 – 1200) mg/m3"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a82e91d884ede9a1b2c4315","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja tlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-EN 15058:2017 | ISO 10396:2007","norm_bases":["PN-EN 15058:2017","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-EN 15058:2017 | ISO 10396:2007 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-EN 15058:2017 | ISO 10396:2007","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon monoxide emission (calculated)","search_en":"Waste gases Carbon monoxide emission (calculated) Testing Laboratory PN-EN 15058:2017 | ISO 10396:2007","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 一氧化碳排放（由计算得出） 检测实验室 PN-EN 15058:2017 | ISO 10396:2007","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4316","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"O2","range":"(0,7 – 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie tlenu\nO2 (0,7 – 21,0) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017 | ISO 10396:2007","norm_bases":["PN-EN 14789:2017","ISO 10396:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nO2 (0,7 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017 | ISO 10396:2007 Gazy odlotowe Stezenie tlenu\nO2 (0,7 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017 | ISO 10396:2007","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Oxygen concentration","parameters_en":[{"name":"O2","range":"(0,7 – 21,0) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method Testing Laboratory O2 PN-EN 14789:2017 | ISO 10396:2007","technique_en":"Paramagnetic method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氧浓度 顺磁法 检测实验室 O2 PN-EN 14789:2017 | ISO 10396:2007","test_object_zh":"废气","parameters_zh":[{"name":"O2","range":"(0,7 – 21,0) %"}],"methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a82e91d884ede9a1b2c4317","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla","parameters":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"computed":[],"activity":"Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Stezenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku wegla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"search_en":"Waste gases Fourier transform infrared spectroscopy (FTIR) Testing Laboratory NO NO2 SO2 CO2 CO ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Fourier transform infrared spectroscopy (FTIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 傅里叶变换红外光谱法（FTIR） 检测实验室 NO NO2 SO2 CO2 CO ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a82e91d884ede9a1b2c4318","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(0,9 – 21,0) %"}],"technique":"Metoda celi cyrkonowej","techniques":["Metoda celi cyrkonowej"],"computed":[],"activity":"Stężenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Stezenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(0,9 – 21,0) %"}],"search_en":"Waste gases Oxygen concentration Zirconia cell method Testing Laboratory Range ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Zirconia cell method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,9 – 21,0) %"}],"search_zh":"废气 氧浓度 检测实验室 范围 ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","methodology_zh":"氧浓度"},{"_id":"6a82e91d884ede9a1b2c4319","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NO2, SO2, CO2, CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NO2, SO2, CO2, CO (z obliczeń)","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NO2, SO2, CO2, CO (z obliczeń) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Emisja NO, NO2, SO2, CO2, CO (z obliczen) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Testing Laboratory ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c431a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4,0 − 40) % obj."},{"name":"Zakres","range":"(3,14 – 57,41) %"}],"technique":"Metoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","techniques":["Metoda kondensacyjno- adsorpcyjna","Metoda temperaturowa"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4,0 − 40) % obj."},{"name":"Range","range":"(3,14 – 57,41) %"}],"search_en":"Waste gases Water vapour concentration (H2O) Condensation- adsorption method; Temperature method Testing Laboratory Range Range PN-EN 14790:2017-04","technique_en":"Condensation- adsorption method; Temperature method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(4,0 − 40) % obj."},{"name":"范围","range":"(3,14 – 57,41) %"}],"search_zh":"废气 水蒸气浓度（H2O） 检测实验室 范围 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a82e91d884ede9a1b2c431b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of SO2 concentration","search_en":"Waste gases Sampling for determination of SO2 concentration Testing Laboratory PN-EN 14791:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 用于测定 SO2 浓度的采样 检测实验室 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a82e91d884ede9a1b2c431c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(5 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(5 – 2000) mg/m3"}],"search_en":"Waste gases SO2 concentration Thoron method Testing Laboratory Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(5 – 2000) mg/m3"}],"search_zh":"废气 SO2 浓度 钍射气法 检测实验室 范围 PN-EN 14791:2017-04","test_object_zh":"废气","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a82e91d884ede9a1b2c431d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 emission (calculated)","search_en":"Waste gases SO2 emission (calculated) Testing Laboratory PN-EN 14791:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 SO2 排放量（计算值） 检测实验室 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c431e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration Testing Laboratory PN-EN 1911:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氯化氢浓度测定采样 检测实验室 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c431f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja chlorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja chlorowodoru (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen chloride emission (calculated)","search_en":"Waste gases Hydrogen chloride emission (calculated) Testing Laboratory PN-EN 1911:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氯化氢排放量（计算值） 检测实验室 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c4320","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Testing Laboratory ISO 15713:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢浓度测定采样 检测实验室 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c4321","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja fluorowodoru (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja fluorowodoru (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen fluoride emission (calculated)","search_en":"Waste gases Hydrogen fluoride emission (calculated) Testing Laboratory ISO 15713:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢排放（由计算得出） 检测实验室 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4322","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211:2006","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of total mercury concentration","search_en":"Waste gases Sampling for determination of total mercury concentration Testing Laboratory PN-EN 13211:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 总汞浓度测定采样 检测实验室 PN-EN 13211:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c4323","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211:2006","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Total mercury emission (calculated)","search_en":"Waste gases Total mercury emission (calculated) Testing Laboratory PN-EN 13211:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 总汞排放量（计算值） 检测实验室 PN-EN 13211:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c4324","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczanie stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczanie stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczanie stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczanie stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","categories":["materials"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Testing Laboratory PN-EN 14385:2025-05","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4325","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Testing Laboratory PN-EN 14385:2025-05","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出） 检测实验室 PN-EN 14385:2025-05","test_object_zh":"废气","methodology_zh":"As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4326","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(1,9 – 290,0) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(1,9 – 290,0) mg/m3"}],"search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Testing Laboratory Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,9 – 290,0) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 检测实验室 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a82e91d884ede9a1b2c4327","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Testing Laboratory PN-EN 12619:2013-05","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） 检测实验室 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c4328","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF","parameters":[],"technique":"Metoda filtracyjno-kondensacyjna","techniques":["Metoda filtracyjno-kondensacyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF\nMetoda filtracyjno-kondensacyjna","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCDD/PCDF\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCDD/PCDF\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for the determination of PCDD/PCDF concentration","search_en":"Waste gases Sampling for the determination of PCDD/PCDF concentration Filtration-condensation method Testing Laboratory PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","technique_en":"Filtration-condensation method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 用于测定 PCDD/PCDF 浓度的采样 过滤-冷凝法 检测实验室 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","technique_zh":"过滤-冷凝法","methodology_zh":"用于测定 PCDD/PCDF 浓度的采样"},{"_id":"6a82e91d884ede9a1b2c4329","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCDD/PCDF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCDD/PCDF (z obliczeń)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja PCDD/PCDF (z obliczeń) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCDD/PCDF (z obliczen) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"PCDD/PCDF emission (calculated)","search_en":"Waste gases PCDD/PCDF emission (calculated) Testing Laboratory PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 PCDD/PCDF 排放（由计算得出） 检测实验室 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","methodology_zh":"PCDD/PCDF 排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c432a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":"Metoda z zastosowaniem węgla aktywnego","techniques":["Metoda z zastosowaniem węgla aktywnego"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda z zastosowaniem węgla aktywnego","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda z zastosowaniem węgla aktywnego PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych\nMetoda z zastosowaniem wegla aktywnego PN-EN 13649:2005","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Method using activated carbon Testing Laboratory PN-EN 13649:2005","technique_en":"Method using activated carbon","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 单项气态有机化合物浓度测定采样 检测实验室 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c432b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Testing Laboratory PN-EN 13649:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 单项气态有机化合物排放量（计算值） 检测实验室 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c432c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","norm_bases":["PN-Z-04030-7:1994","Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the dust fraction","search_en":"Waste gases Sampling for determination of the dust fraction Testing Laboratory PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 用于测定粉尘分级的采样 检测实验室 PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a82e91d884ede9a1b2c432d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja frakcji pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","norm_bases":["PN-Z-04030-7:1994","Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of the dust fraction (calculated)","search_en":"Waste gases Emission of the dust fraction (calculated) Testing Laboratory PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘分级排放（由计算得出） 检测实验室 PN-Z-04030-7:1994 | Instrukcja badawcza ILB/5.6/1 wersja 2 z dnia 15.06.2016 roku","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c432e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie amoniaku (NH3)","parameters":[{"name":"Zakres","range":"(1,1 – 36) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"computed":[],"activity":"Stężenie amoniaku (NH3)\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie amoniaku (NH3)\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Stezenie amoniaku (NH3)\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia (NH3) concentration","parameters_en":[{"name":"Range","range":"(1,1 – 36) mg/m3"}],"search_en":"Waste gases Ammonia (NH3) concentration Fourier transform infrared spectroscopy (FTIR) Testing Laboratory Range ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Fourier transform infrared spectroscopy (FTIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,1 – 36) mg/m3"}],"search_zh":"废气 傅里叶变换红外光谱法（FTIR） 检测实验室 范围 ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a82e91d884ede9a1b2c432f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (NH3) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (NH3) (z obliczeń)","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (NH3) (z obliczeń) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Emisja amoniaku (NH3) (z obliczen) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia (NH3) emission (calculated)","search_en":"Waste gases Ammonia (NH3) emission (calculated) Testing Laboratory ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氨（NH3）排放（由计算得出） 检测实验室 ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","methodology_zh":"氨（NH3）排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4330","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku (NH3) PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku (NH3) PN-EN ISO 21877:2020-03","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for the determination of ammonia (NH3) concentration","search_en":"Waste gases Sampling for the determination of ammonia (NH3) concentration Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN ISO 21877:2020-03","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4331","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (NH3) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (NH3) (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (NH3) (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (NH3) (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia (NH3) emission (calculated)","search_en":"Waste gases Ammonia (NH3) emission (calculated) Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氨（NH3）排放（由计算得出） 检测实验室 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨（NH3）排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4332","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO3, H2SO4","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO3, H2SO4","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO3, H2SO4 VDI 2462-2:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO3, H2SO4 VDI 2462-2:2011","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Testing Laboratory VDI 2462-2:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 VDI 2462-2:2011","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4333","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO3, H2SO4","parameters":[{"name":"SO3","range":"(5,0 – 50) mg/m3"},{"name":"H2SO4","range":"(3,6 – 50) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO3, H2SO4\nZakres:\nSO3 (5,0 – 50) mg/m3\nH2SO4 (3,6 – 50) mg/m3\nMetoda toronowa","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie SO3, H2SO4\nZakres:\nSO3 (5,0 – 50) mg/m3\nH2SO4 (3,6 – 50) mg/m3\nMetoda toronowa VDI 2462-2:2011 Gazy odlotowe Stezenie SO3, H2SO4\nZakres:\nSO3 (5,0 – 50) mg/m3\nH2SO4 (3,6 – 50) mg/m3\nMetoda toronowa VDI 2462-2:2011","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"SO3","range":"(5,0 – 50) mg/m3"},{"name":"H2SO4","range":"(3,6 – 50) mg/m3"}],"search_en":"Waste gases Thoron method Testing Laboratory SO3 VDI 2462-2:2011","technique_en":"Thoron method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 钍射气法 检测实验室 VDI 2462-2:2011","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a82e91d884ede9a1b2c4334","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO3, H2SO4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO3, H2SO4 (z obliczeń)","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja SO3, H2SO4 (z obliczeń) VDI 2462-2:2011 Gazy odlotowe Emisja SO3, H2SO4 (z obliczen) VDI 2462-2:2011","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of SO3, H2SO4 (calculated)","search_en":"Waste gases Emission of SO3, H2SO4 (calculated) Testing Laboratory VDI 2462-2:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 VDI 2462-2:2011","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4335","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(8,0 – 2400) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie SO2\nZakres (8,0 – 2400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","norm_bases":["PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (8,0 – 2400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku Gazy odlotowe Stezenie SO2\nZakres (8,0 – 2400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(8,0 – 2400) mg/m3"}],"search_en":"Waste gases SO2 concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(8,0 – 2400) mg/m3"}],"search_zh":"废气 SO2 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"SO2 浓度"},{"_id":"6a82e91d884ede9a1b2c4336","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NO, NOx","parameters":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"technique":"Metoda chemiluminescencyjna CLD","techniques":["Metoda chemiluminescencyjna CLD"],"computed":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna CLD","reference":"PN-EN 14792:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","norm_bases":["PN-EN 14792:2017","PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie NO, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna CLD PN-EN 14792:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku Gazy odlotowe Stezenie NO, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna CLD PN-EN 14792:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"NO, NOx concentration","parameters_en":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"search_en":"Waste gases NO, NOx concentration Chemiluminescence method CLD Testing Laboratory NO NOx PN-EN 14792:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","technique_en":"Chemiluminescence method CLD","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 NO、NOx 浓度 检测实验室 NO NOx PN-EN 14792:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"methodology_zh":"NO、NOx 浓度"},{"_id":"6a82e91d884ede9a1b2c4337","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(3,0 – 1200) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO\nZakres (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","norm_bases":["PN-EN 15058:2017","PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie CO\nZakres (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku Gazy odlotowe Stezenie CO\nZakres (3,0 – 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(3,0 – 1200) mg/m3"}],"search_en":"Waste gases CO concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-EN 15058:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(3,0 – 1200) mg/m3"}],"search_zh":"废气 CO 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-EN 15058:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO 浓度"},{"_id":"6a82e91d884ede9a1b2c4338","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(0,7 – 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (0,7 – 21,0) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","norm_bases":["PN-EN 14789:2017","PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie O2\nZakres (0,7 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku Gazy odlotowe Stezenie O2\nZakres (0,7 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(0,7 – 21,0) %"}],"search_en":"Waste gases O2 concentration Paramagnetic method Testing Laboratory Range PN-EN 14789:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","technique_en":"Paramagnetic method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,7 – 21,0) %"}],"search_zh":"废气 O2 浓度 顺磁法 检测实验室 范围 PN-EN 14789:2017 | PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","test_object_zh":"废气","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a82e91d884ede9a1b2c4339","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,6 – 18) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","norm_bases":["PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku Gazy odlotowe Stezenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,6 – 18) %"}],"search_en":"Waste gases CO2 concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,6 – 18) %"}],"search_zh":"废气 CO2 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/5 wersja 2 z dnia 29.05.2018 roku","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a82e91d884ede9a1b2c433a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla","parameters":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"NH3","range":"(1,1 – 36) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"computed":[],"activity":"Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nNH3 (1,1 – 36) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nNH3 (1,1 – 36) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Stezenie tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku wegla\nZakres:\nNO (5,9 – 1050) mg/m3\nNO2 (4,4 – 100) mg/m3\nSO2 (13,2 – 5100) mg/m3\nNH3 (1,1 – 36) mg/m3\nCO2 (1,0 – 22,0) %\nCO (2,1 – 1800) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"NH3","range":"(1,1 – 36) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"search_en":"Waste gases Fourier transform infrared spectroscopy (FTIR) Testing Laboratory NO NO2 SO2 NH3 CO2 CO PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Fourier transform infrared spectroscopy (FTIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 傅里叶变换红外光谱法（FTIR） 检测实验室 NO NO2 SO2 CO2 CO PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(5,9 – 1050) mg/m3"},{"name":"NO2","range":"(4,4 – 100) mg/m3"},{"name":"SO2","range":"(13,2 – 5100) mg/m3"},{"name":"NH3","range":"(1,1 – 36) mg/m3"},{"name":"CO2","range":"(1,0 – 22,0) %"},{"name":"CO","range":"(2,1 – 1800) mg/m3"}],"technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a82e91d884ede9a1b2c433b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(0,9 – 21,0) %"}],"technique":"Metoda celi cyrkonowej","techniques":["Metoda celi cyrkonowej"],"computed":[],"activity":"Stężenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej","reference":"PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Stezenie tlenu\nZakres (0,9 – 21,0) %\nMetoda celi cyrkonowej PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(0,9 – 21,0) %"}],"search_en":"Waste gases Oxygen concentration Zirconia cell method Testing Laboratory Range PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Zirconia cell method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,9 – 21,0) %"}],"search_zh":"废气 氧浓度 检测实验室 范围 PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气","methodology_zh":"氧浓度"},{"_id":"6a82e91d884ede9a1b2c433c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NO2, SO2, NH3, CO2, CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NO2, SO2, NH3, CO2, CO (z obliczeń)","reference":"PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["PN-ISO 10396:2001","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NO, NO2, SO2, NH3, CO2, CO (z obliczeń) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Gazy odlotowe Emisja NO, NO2, SO2, NH3, CO2, CO (z obliczen) PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Testing Laboratory PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-ISO 10396:2001 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c433d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: Se, Zn","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: Se, Zn","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: Se, Zn PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: Se, Zn PN-EN 14385:2025-05","categories":["materials"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of metal concentrations: Se, Zn","search_en":"Waste gases Sampling for determination of metal concentrations: Se, Zn Testing Laboratory PN-EN 14385:2025-05","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c433e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: Se, Zn (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: Se, Zn (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali: Se, Zn (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja metali: Se, Zn (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of metals: Se, Zn (calculated)","search_en":"Waste gases Emission of metals: Se, Zn (calculated) Testing Laboratory PN-EN 14385:2025-05","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c433f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCB typu dioksyn","parameters":[],"technique":"Metoda filtracyjno-kondensacyjna","techniques":["Metoda filtracyjno-kondensacyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Filtration-condensation method Testing Laboratory PN-EN 1948-4+A1:2014-03","technique_en":"Filtration-condensation method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 过滤-冷凝法 检测实验室 PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","technique_zh":"过滤-冷凝法"},{"_id":"6a82e91d884ede9a1b2c4340","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCB typu dioksyn (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCB typu dioksyn (z obliczeń)","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja PCB typu dioksyn (z obliczeń) PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCB typu dioksyn (z obliczen) PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of dioxin-like PCB (calculated)","search_en":"Waste gases Emission of dioxin-like PCB (calculated) Testing Laboratory PN-EN 1948-4+A1:2014-03","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-EN 1948-4+A1:2014-03","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4341","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania masowego stężenia WWA","parameters":[],"technique":"Metoda filtracyjno-kondensacyjno-absorpcyjna","techniques":["Metoda filtracyjno-kondensacyjno-absorpcyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczania masowego stężenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna","reference":"ISO 11338-1:2003","norm_bases":["ISO 11338-1:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego stężenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna ISO 11338-1:2003 Gazy odlotowe Pobieranie probek do oznaczania masowego stezenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna ISO 11338-1:2003","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Waste gases Testing Laboratory ISO 11338-1:2003","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 ISO 11338-1:2003","test_object_zh":"废气"},{"_id":"6a82e91d884ede9a1b2c4342","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja WWA (z obliczeń)","reference":"ISO 11338-1:2003","norm_bases":["ISO 11338-1:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja WWA (z obliczeń) ISO 11338-1:2003 Gazy odlotowe Emisja WWA (z obliczen) ISO 11338-1:2003","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"PAH emission (calculated)","search_en":"Waste gases PAH emission (calculated) Testing Laboratory ISO 11338-1:2003","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 多环芳烃排放（由计算得出） 检测实验室 ISO 11338-1:2003","test_object_zh":"废气","methodology_zh":"多环芳烃排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4343","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie N2O","parameters":[{"name":"Zakres","range":"(1,4 – 285,0) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Gazy odlotowe Stezenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"N2O concentration","parameters_en":[{"name":"Range","range":"(1,4 – 285,0) mg/m3"}],"search_en":"Waste gases N2O concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-EN ISO 21258:2010","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,4 – 285,0) mg/m3"}],"search_zh":"废气 N2O 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-EN ISO 21258:2010","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a82e91d884ede9a1b2c4344","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja N2O (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 Gazy odlotowe Emisja N2O (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"N2O emission (calculated)","search_en":"Waste gases N2O emission (calculated) Testing Laboratory PN-EN ISO 21258:2010","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 N2O 排放（由计算得出） 检测实验室 PN-EN ISO 21258:2010","test_object_zh":"废气","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4345","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"CEN/TS 17340:2020-09","norm_bases":["CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru CEN/TS 17340:2020-09 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru CEN/TS 17340:2020-09","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Testing Laboratory CEN/TS 17340:2020-09","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢浓度测定采样 检测实验室 CEN/TS 17340:2020-09","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c4346","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"CEN/TS 17340:2020-09","norm_bases":["CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja fluorowodoru (z obliczeń) CEN/TS 17340:2020-09 Gazy odlotowe Emisja fluorowodoru (z obliczen) CEN/TS 17340:2020-09","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen fluoride emission (calculated)","search_en":"Waste gases Hydrogen fluoride emission (calculated) Testing Laboratory CEN/TS 17340:2020-09","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢排放（由计算得出） 检测实验室 CEN/TS 17340:2020-09","test_object_zh":"废气","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4347","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru (H2S)","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworu pochłaniającego","techniques":["Metoda aspiracyjna z zastosowaniem roztworu pochłaniającego"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru (H2S)\nMetoda aspiracyjna z zastosowaniem roztworu pochłaniającego","reference":"VDI 3486 Blatt 2:1979","norm_bases":["VDI 3486 Blatt 2:1979"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia siarkowodoru (H2S)\nMetoda aspiracyjna z zastosowaniem roztworu pochłaniającego VDI 3486 Blatt 2:1979 Gazy odlotowe Pobieranie probek do oznaczania stezenia siarkowodoru (H2S)\nMetoda aspiracyjna z zastosowaniem roztworu pochlaniajacego VDI 3486 Blatt 2:1979","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen sulfide concentration (H2S)","search_en":"Waste gases Sampling for determination of hydrogen sulfide concentration (H2S) Aspiration method using an absorbing solution Testing Laboratory VDI 3486 Blatt 2:1979","technique_en":"Aspiration method using an absorbing solution","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 使用吸收液的抽气采样法 检测实验室 VDI 3486 Blatt 2:1979","test_object_zh":"废气","technique_zh":"使用吸收液的抽气采样法"},{"_id":"6a82e91d884ede9a1b2c4348","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja siarkowodoru (H2S) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja siarkowodoru (H2S) (z obliczeń)","reference":"VDI 3486 Blatt 2:1979","norm_bases":["VDI 3486 Blatt 2:1979"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja siarkowodoru (H2S) (z obliczeń) VDI 3486 Blatt 2:1979 Gazy odlotowe Emisja siarkowodoru (H2S) (z obliczen) VDI 3486 Blatt 2:1979","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen sulfide (H2S) emission (calculated)","search_en":"Waste gases Hydrogen sulfide (H2S) emission (calculated) Testing Laboratory VDI 3486 Blatt 2:1979","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 硫化氢（H2S）排放（由计算得出） 检测实验室 VDI 3486 Blatt 2:1979","test_object_zh":"废气","methodology_zh":"硫化氢（H2S）排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4349","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg PN-EN 14181:2015 Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny, HCl, HF, Hg PN-EN 14181:2015","categories":["metrology"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Automated Measuring Systems (AMS) Testing Laboratory PN-EN 14181:2015","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 检测实验室 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c434a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, HCl, HF, Hg PN-EN 14181:2015 Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pylu, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny, HCl, HF, Hg PN-EN 14181:2015","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Automated Measuring Systems (AMS) Testing Laboratory PN-EN 14181:2015","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 检测实验室 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c434b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Testing Laboratory Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 检测实验室 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c434c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,48 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu\nZakres (0,48 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,48 – 50) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Testing Laboratory Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,48 – 50) mg/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 检测实验室 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c434d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(5 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(5 – 2000) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Testing Laboratory Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(5 – 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 检测实验室 范围 PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a82e91d884ede9a1b2c434e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie NO, NO2, NOx","parameters":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie NO, NO2, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017","norm_bases":["PN-EN 14792:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie NO, NO2, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017 Automatyczne Systemy Monitoringu (AMS) Stezenie NO, NO2, NOx\nZakres:\nNO (2,3 – 620) mg/m3\nNO2 (3,6 – 950) mg/m3\nNOx (3,6 – 950) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"NO, NO2, NOx concentration","parameters_en":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) NO, NO2, NOx concentration Chemiluminescence method Testing Laboratory NO NO2 NOx PN-EN 14792:2017","technique_en":"Chemiluminescence method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） NO、NO2、NOx 浓度 化学发光法 检测实验室 NO NO2 NOx PN-EN 14792:2017","parameters_zh":[{"name":"NO","range":"(2,3 – 620) mg/m3"},{"name":"NO2","range":"(3,6 – 950) mg/m3"},{"name":"NOx","range":"(3,6 – 950) mg/m3"}],"test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法","methodology_zh":"NO、NO2、NOx 浓度"},{"_id":"6a82e91d884ede9a1b2c434f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(3,0 - 1200) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO\nZakres (3,0 - 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017","norm_bases":["PN-EN 15058:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie CO\nZakres (3,0 - 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017 Automatyczne Systemy Monitoringu (AMS) Stezenie CO\nZakres (3,0 - 1200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(3,0 - 1200) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) CO concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-EN 15058:2017","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(3,0 - 1200) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-EN 15058:2017","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO 浓度"},{"_id":"6a82e91d884ede9a1b2c4350","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(0,7 – 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (0,7 – 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017","norm_bases":["PN-EN 14789:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie O2\nZakres (0,7 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017 Automatyczne Systemy Monitoringu (AMS) Stezenie O2\nZakres (0,7 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(0,7 – 21) %"}],"search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Testing Laboratory Range PN-EN 14789:2017","technique_en":"Paramagnetic method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,7 – 21) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 检测实验室 范围 PN-EN 14789:2017","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a82e91d884ede9a1b2c4351","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4,0 − 40) % obj."},{"name":"Zakres","range":"(3,14 – 57,41) %"}],"technique":"Metoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","techniques":["Metoda kondensacyjno- adsorpcyjna","Metoda temperaturowa"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres:\nZakres (4,0 − 40) % obj.\nZakres (3,14 – 57,41) %\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4,0 − 40) % obj."},{"name":"Range","range":"(3,14 – 57,41) %"}],"search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Condensation- adsorption method; Temperature method Testing Laboratory Range Range PN-EN 14790:2017-04","technique_en":"Condensation- adsorption method; Temperature method","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(4,0 − 40) % obj."},{"name":"范围","range":"(3,14 – 57,41) %"}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 检测实验室 范围 范围 PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a82e91d884ede9a1b2c4352","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(1,9 – 290,0) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Automatyczne Systemy Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,9 – 290,0) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(1,9 – 290,0) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Testing Laboratory Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,9 – 290,0) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 检测实验室 范围 PN-EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a82e91d884ede9a1b2c4353","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O PN-EN 14181:2015 Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O PN-EN 14181:2015","categories":["metrology"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Calibration of AMS (QAL2) for: NH3, N2O","search_en":"Automated Measuring Systems (AMS) Calibration of AMS (QAL2) for: NH3, N2O Testing Laboratory PN-EN 14181:2015","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 检测实验室 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c4354","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: NH3, N2O","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: NH3, N2O","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: NH3, N2O PN-EN 14181:2015 Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: NH3, N2O PN-EN 14181:2015","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Annual surveillance test (AST) for: NH3, N2O","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: NH3, N2O Testing Laboratory PN-EN 14181:2015","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 检测实验室 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a82e91d884ede9a1b2c4355","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie NH3","parameters":[{"name":"Zakres","range":"(1,1 – 36) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"computed":[],"activity":"Stężenie NH3\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","norm_bases":["ISO 10396:2007","Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie NH3\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku Automatyczne Systemy Monitoringu (AMS) Stezenie NH3\nZakres (1,1 – 36) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"NH3 concentration","parameters_en":[{"name":"Range","range":"(1,1 – 36) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) NH3 concentration Fourier transform infrared spectroscopy (FTIR) Testing Laboratory Range ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","technique_en":"Fourier transform infrared spectroscopy (FTIR)","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,1 – 36) mg/m3"}],"search_zh":"自动测量系统（AMS） NH3 浓度 傅里叶变换红外光谱法（FTIR） 检测实验室 范围 ISO 10396:2007 | Instrukcja badawcza ILB/5.4/.4 wersja 4 z dnia 09.06.2018 roku","test_object_zh":"自动测量系统（AMS）","methodology_zh":"NH3 浓度","technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a82e91d884ede9a1b2c4356","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie N2O","parameters":[{"name":"Zakres","range":"(1,4 – 285,0) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Automatyczne Systemy Monitoringu (AMS) Stezenie N2O\nZakres (1,4 – 285,0) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"N2O concentration","parameters_en":[{"name":"Range","range":"(1,4 – 285,0) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) N2O concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PN-EN ISO 21258:2010","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1,4 – 285,0) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 PN-EN ISO 21258:2010","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"自动测量系统（AMS）","methodology_zh":"N2O 浓度"},{"_id":"6a82e91d884ede9a1b2c4357","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Emisja N2O (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 Automatyczne Systemy Monitoringu (AMS) Emisja N2O (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"N2O emission (calculated)","search_en":"Automated Measuring Systems (AMS) N2O emission (calculated) Testing Laboratory PN-EN ISO 21258:2010","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） N2O 排放（由计算得出） 检测实验室 PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c4358","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Automated Measuring Systems (AMS) Sampling for determination of hydrogen chloride concentration Testing Laboratory PN-EN 1911:2011","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氯化氢浓度测定采样 检测实验室 PN-EN 1911:2011","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c4359","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Emisja chlorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Emisja chlorowodoru (z obliczeń) PN-EN 1911:2011 Automatyczne Systemy Monitoringu (AMS) Emisja chlorowodoru (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen chloride emission (calculated)","search_en":"Automated Measuring Systems (AMS) Hydrogen chloride emission (calculated) Testing Laboratory PN-EN 1911:2011","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氯化氢排放量（计算值） 检测实验室 PN-EN 1911:2011","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c435a","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006 | CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006","CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 | CEN/TS 17340:2020-09 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006 | CEN/TS 17340:2020-09","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Automated Measuring Systems (AMS) Sampling for determination of hydrogen fluoride concentration Testing Laboratory ISO 15713:2006 | CEN/TS 17340:2020-09","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氟化氢浓度测定采样 检测实验室 ISO 15713:2006 | CEN/TS 17340:2020-09","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c435b","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Emisja fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"ISO 15713:2006 | CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006","CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Emisja fluorowodoru (z obliczeń) ISO 15713:2006 | CEN/TS 17340:2020-09 Automatyczne Systemy Monitoringu (AMS) Emisja fluorowodoru (z obliczen) ISO 15713:2006 | CEN/TS 17340:2020-09","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen fluoride emission (calculated)","search_en":"Automated Measuring Systems (AMS) Hydrogen fluoride emission (calculated) Testing Laboratory ISO 15713:2006 | CEN/TS 17340:2020-09","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氟化氢排放（由计算得出） 检测实验室 ISO 15713:2006 | CEN/TS 17340:2020-09","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a82e91d884ede9a1b2c435c","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211:2006 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211:2006","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of total mercury concentration","search_en":"Automated Measuring Systems (AMS) Sampling for determination of total mercury concentration Testing Laboratory PN-EN 13211:2006","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 总汞浓度测定采样 检测实验室 PN-EN 13211:2006","test_object_zh":"自动测量系统（AMS）","methodology_zh":"总汞浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c435d","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Emisja rtęci ogólnej (z obliczeń) PN-EN 13211:2006 Automatyczne Systemy Monitoringu (AMS) Emisja rteci ogolnej (z obliczen) PN-EN 13211:2006","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Total mercury emission (calculated)","search_en":"Automated Measuring Systems (AMS) Total mercury emission (calculated) Testing Laboratory PN-EN 13211:2006","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 总汞排放量（计算值） 检测实验室 PN-EN 13211:2006","test_object_zh":"自动测量系统（AMS）","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c435e","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Automated Measuring Systems (AMS) Sampling for determination of ammonia concentration Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氨浓度测定采样 检测实验室 PN-EN ISO 21877:2020-03","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨浓度测定采样"},{"_id":"6a82e91d884ede9a1b2c435f","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Automatyczne Systemy Monitoringu (AMS) Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia emission (calculated)","search_en":"Automated Measuring Systems (AMS) Ammonia emission (calculated) Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","search_zh":"自动测量系统（AMS） 氨排放量（计算值） 检测实验室 PN-EN ISO 21877:2020-03","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨排放量（计算值）"},{"_id":"6a82e91d884ede9a1b2c4360","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,6 – 18) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 10396:2007 | ISO 12039:2019","norm_bases":["ISO 10396:2007","ISO 12039:2019"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007 | ISO 12039:2019 Automatyczne Systemy Monitoringu (AMS) Stezenie CO2\nZakres (0,6 – 18) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007 | ISO 12039:2019","categories":["other"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,6 – 18) %"}],"search_en":"Automated Measuring Systems (AMS) CO2 concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range ISO 10396:2007 | ISO 12039:2019","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Automated Measuring Systems (AMS)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,6 – 18) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外光谱法（NDIR） 检测实验室 范围 ISO 10396:2007 | ISO 12039:2019","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO2 浓度"},{"_id":"6a82e91d884ede9a1b2c4361","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas","methodology":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A","parameters":[{"name":"Zakres","range":"(26,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4","PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3","DIN 45635-46:1985-06","DIN 45635-47:1985-06","ISO 10494:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 Maszyny i urzadzenia w tym wieze chlodnicze, kominy, turbiny i turbozespoly – halas Poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wylaczeniem punktu 8.4 | PN-EN ISO 3744:2011 z wylaczeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-frequency-weighted sound pressure level","parameters_en":[{"name":"Range","range":"(26,0 – 136,0) dB"}],"search_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise A-frequency-weighted sound pressure level Direct measurement method Testing Laboratory Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(26,0 – 136,0) dB"}],"search_zh":"直接测量法 检测实验室 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","technique_zh":"直接测量法"},{"_id":"6a82e91d884ede9a1b2c4362","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas","methodology":"Poziom ciśnienia akustycznego w pasmach 1/1 i 1/3 oktawowych w zakresie częstotliwości środkowych","parameters":[{"name":"Zakres","range":"(20 – 20 000) Hz"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego w pasmach 1/1 i 1/3 oktawowych w zakresie częstotliwości środkowych\nZakres (20 – 20 000) Hz\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4","PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3","DIN 45635-46:1985-06","DIN 45635-47:1985-06","ISO 10494:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas Poziom ciśnienia akustycznego w pasmach 1/1 i 1/3 oktawowych w zakresie częstotliwości środkowych\nZakres (20 – 20 000) Hz\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 Maszyny i urzadzenia w tym wieze chlodnicze, kominy, turbiny i turbozespoly – halas Poziom cisnienia akustycznego w pasmach 1/1 i 1/3 oktawowych w zakresie czestotliwosci srodkowych\nZakres (20 – 20 000) Hz\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wylaczeniem punktu 8.4 | PN-EN ISO 3744:2011 z wylaczeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"(20 – 20 000) Hz"}],"search_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise Direct measurement method Testing Laboratory Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(20 – 20 000) Hz"}],"search_zh":"直接测量法 检测实验室 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","technique_zh":"直接测量法"},{"_id":"6a82e91d884ede9a1b2c4363","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4","PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3","DIN 45635-46:1985-06","DIN 45635-47:1985-06","ISO 10494:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespoły – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 Maszyny i urzadzenia w tym wieze chlodnicze, kominy, turbiny i turbozespoly – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wylaczeniem punktu 8.4 | PN-EN ISO 3744:2011 z wylaczeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise Sound power level (calculated) Testing Laboratory PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","test_object_en":"Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise","lab_section_zh":"检测实验室","search_zh":"声功率级（计算值） 检测实验室 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem punktu 8.4 | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018","methodology_zh":"声功率级（计算值）"},{"_id":"6a82e91d884ede9a1b2c4364","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(26,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(26,0 – 136,0) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(26,0 – 136,0) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 检测实验室 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a82e91d884ede9a1b2c4365","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda obliczeniowa","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) | PN ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706)","PN ISO 9613-2:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda obliczeniowa Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) | PN ISO 9613-2:2002 Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)\nMetoda obliczeniowa Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) | PN ISO 9613-2:2002","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Calculation method Testing Laboratory Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) | PN ISO 9613-2:2002","technique_en":"Calculation method","test_object_en":"General environment - noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 计算法 检测实验室 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706) | PN ISO 9613-2:2002","technique_zh":"计算法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a82e91d884ede9a1b2c4366","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(26,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(26,0 – 136,0) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(26,0 – 136,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 直接测量法 检测实验室 范围 PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82e91d884ede9a1b2c4367","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(26,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Maksymalny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Maksymalny poziom dźwięku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Maksymalny poziom dzwieku A\nZakres (26,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Maximum A-weighted sound pressure level","parameters_en":[{"name":"Range","range":"(26,0 – 136,0) dB"}],"search_en":"Workplace environment - noise Maximum A-weighted sound pressure level Direct measurement method Testing Laboratory Range PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(26,0 – 136,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权最大声级 直接测量法 检测实验室 范围 PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权最大声级"},{"_id":"6a82e91d884ede9a1b2c4368","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(40,0 – 138,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (40,0 – 138,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Szczytowy poziom dźwięku C\nZakres (40,0 – 138,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Szczytowy poziom dzwieku C\nZakres (40,0 – 138,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(40,0 – 138,0) dB"}],"search_en":"Workplace environment - noise C-weighted peak sound pressure level Direct measurement method Testing Laboratory Range PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"检测实验室","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(40,0 – 138,0) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 检测实验室 范围 PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82e91d884ede9a1b2c4369","lab_id":"69ad52a3de79e566650fb887","country":"PL","accr_number":"AB 1624","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy, - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy, - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy, - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy, - przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Noise exposure level referred to: - an 8-hour daily working time, - an average weekly working time (calculated)","search_en":"Workplace environment - noise Noise exposure level referred to: - an 8-hour daily working time, - an average weekly working time (calculated) Testing Laboratory PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","test_object_en":"Workplace environment - noise","lab_section_zh":"检测实验室","search_zh":"工作场所环境 — 噪声 检测实验室 PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","test_object_zh":"工作场所环境 — 噪声"}],"has_pdf":true}