{"lab":{"_id":"69ad52a3de79e566650fb881","accr_number":"AB 1621","country":"PL","accr_body":"PCA","address":"ul. Wrocławska 33B lok. 1, 55-095 Długołęka","categories":["environment","metrology","construction"],"city":"Długołęka","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"ECO-NOISE PAWEŁ NIŻNIOWSKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1621.pdf"],"scope_summary":"","search_text":"eco-noise paweł niżniowski ul. wrocławska 33b lok. 1, 55-095 długołęka environment metrology other construction","status":"active","updated_at":"2026-03-08T14:50:45.220Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:45.220Z","email_confidence":"high","email_mx":true,"email_source":"https://eco-noise.pl/kontakt/","parse_date":"2026-07-17T16:19:16.395Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"A/5, A/13","pl":"Badania akustyczne i drgań - obiekty budowlane, maszyny i urządzenia","en":"Acoustic and vibration tests of building items, machinery and devices,"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska- środowisko pracy (czynniki szkodliwe – hałas), środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) of workplace (harmful factors – noise), general environment (physical factors - noise)"}],"issue":{"no":"12","date":"20.08.2025"},"map_coord":[51.174617,17.174847],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":22,"metrology":6,"construction":5,"other":2},"category_scores":{"environment":13.83,"metrology":1.03,"construction":0.71,"other":0.11},"has_zh":true},"methods":[{"_id":"6a5a56049af9f73f38254794","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","norm_bases":["nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.)","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 范围：(24 – 135) dB 直接测量法 nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"A 计权等效声级 范围：(24 – 135) dB 直接测量法"},{"_id":"6a5a56049af9f73f38254795","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5a56049af9f73f38254796","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa","methodology_en":"A-weighted equivalent sound level for reference time T expressed as LAeqD and LAeqN indices Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN Metoda obliczeniowa","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as LAeqD and LAeqN indices Calculation method","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级 计算法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级 计算法"},{"_id":"6a5a56049af9f73f38254797","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń","test_object_en":"General environment − impulse noise from installations and equipment","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002","norm_bases":["nr 8","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002 Srodowisko ogolne − halas impulsowy pochodzacy od instalacji i urzadzen Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia nr 8 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations and equipment A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002","search_zh":"一般环境 － 来自装置与设备的脉冲噪声 nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 10843:2002","test_object_zh":"一般环境 － 来自装置与设备的脉冲噪声"},{"_id":"6a5a56049af9f73f38254798","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń","test_object_en":"General environment − impulse noise from installations and equipment","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne − halas impulsowy pochodzacy od instalacji i urzadzen Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations and equipment A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置与设备的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 － 来自装置与设备的脉冲噪声"},{"_id":"6a5a56049af9f73f38254799","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","test_object_en":"General environment – noise from airports","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"nr 2 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140","norm_bases":["nr 2","enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia nr 2 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140 Srodowisko ogolne – halas pochodzacy od lotnisk Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia nr 2 | enia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. nr 140","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from airports A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method nr 2 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140","search_zh":"一般环境 — 来自机场的噪声 A 计权等效声级 A 计权声暴露级 范围：(24 – 135) dB 直接测量法 nr 2 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140","test_object_zh":"一般环境 — 来自机场的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级 范围：(24 – 135) dB 直接测量法"},{"_id":"6a5a56049af9f73f3825479a","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","test_object_en":"General environment – noise from airports","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od lotnisk Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自机场的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 — 来自机场的噪声"},{"_id":"6a5a56049af9f73f3825479b","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 135) dB Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 范围：(24 – 135) dB 直接测量法 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i Nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) NMPB-Routes-2008 NMPB-Routes-96/ NFS 31-133 (XPS 31-133) RLS 90 RMR/SRM II Schall 03","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级 范围：(24 – 135) dB 直接测量法"},{"_id":"6a5a56049af9f73f3825479c","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a56049af9f73f3825479d","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa","methodology_en":"A-weighted equivalent sound level for reference time T expressed as LAeqD and LAeqN indices Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Metoda obliczeniowa Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN Metoda obliczeniowa","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level for reference time T expressed as LAeqD and LAeqN indices Calculation method","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级 计算法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级 计算法"},{"_id":"6a5a56049af9f73f3825479e","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne: ekrany akustyczne „in situ”","test_object_en":"General environment: noise barriers „in situ”","methodology":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne: ekrany akustyczne „in situ” Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia PN-ISO 10847:2002 Srodowisko ogolne: ekrany akustyczne „in situ” Rownowazny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia PN-ISO 10847:2002","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment: noise barriers „in situ” A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method PN-ISO 10847:2002","methodology_zh":"A 计权等效声级 范围：(24 – 135) dB 直接测量法","search_zh":"A 计权等效声级 范围：(24 – 135) dB 直接测量法 PN-ISO 10847:2002"},{"_id":"6a5a56049af9f73f3825479f","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko ogólne: ekrany akustyczne „in situ”","test_object_en":"General environment: noise barriers „in situ”","methodology":"Skuteczność ekranów (z obliczeń)","methodology_en":"Effectiveness of screens (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ekranów (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne: ekrany akustyczne „in situ” Skuteczność ekranów (z obliczeń) Srodowisko ogolne: ekrany akustyczne „in situ” Skutecznosc ekranow (z obliczen)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment: noise barriers „in situ” Effectiveness of screens (calculated)","methodology_zh":"屏蔽效能（由计算得出）","search_zh":"屏蔽效能（由计算得出）"},{"_id":"6a5a56049af9f73f382547a0","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A Zakres: (24 – 135) dB Metoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A Zakres: (24 – 135) dB Metoda pomiarowa bezposrednia PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise A-weighted equivalent sound level Range: (24 – 135) dB Direct measurement method PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09","search_zh":"机器与设备 – 噪声 A 计权等效声级 范围：(24 – 135) dB 直接测量法 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"A 计权等效声级 范围：(24 – 135) dB 直接测量法"},{"_id":"6a5a56049af9f73f382547a1","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Poziom mocy akustycznej (z obliczeń)","methodology_en":"Sound power level (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment – noise Sound power level (calculated)","search_zh":"机器与设备 – 噪声 声功率级（计算值）","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a5a56049af9f73f382547a2","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (24 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 138) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (24 – 135) dB C-weighted peak sound level Range: (40 – 138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (24 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 138) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (24 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 138) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (24 – 135) dB Szczytowy poziom dzwieku C Zakres: (40 – 138) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 p. 10 i Strategie 3 p. 11","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (24 – 135) dB C-weighted peak sound level Range: (40 – 138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a56049af9f73f382547a3","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","methodology_zh":"噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","search_zh":"工作场所环境 — 噪声 噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a56049af9f73f382547a4","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (21 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (21 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (21 – 135) dB Metoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (21 – 135) dB Metoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (21 – 135) dB Metoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (21 – 135) dB Direct measurement method PN-87/B-02156","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a5a56049af9f73f382547a5","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated)","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出）","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a5a56049af9f73f382547a6","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego","test_object_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment","methodology":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres: (21 – 136) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range: (21 – 136) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres: (21 – 136) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres: (21 – 136) dB Metoda pomiarowa bezpośrednia PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas od urzadzen wyposazenia technicznego Rownowazny poziom dzwieku A, C Maksymalny poziom dzwieku A, C Zakres: (21 – 136) dB Metoda pomiarowa bezposrednia PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range: (21 – 136) dB Direct measurement method PN-EN ISO 10052:2021-12","search_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声 PN-EN ISO 10052:2021-12","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声"},{"_id":"6a5a56049af9f73f382547a7","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego","test_object_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment","methodology":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","methodology_en":"Reference equivalent A, C sound level for the operating cycle Reference maximum A, C sound level for the operating cycle (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń) Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas od urzadzen wyposazenia technicznego Wzorcowy rownowazny poziom dzwieku A, C dla cyklu pracy Wzorcowy maksymalny poziom dzwieku A, C dla cyklu pracy (z obliczen)","categories":["environment","metrology"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment Reference equivalent A, C sound level for the operating cycle Reference maximum A, C sound level for the operating cycle (calculated)","search_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声"},{"_id":"6a5a56049af9f73f382547a8","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego","test_object_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment","methodology":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres (24-135) dB Poziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych: (31,5 – 8 000 Hz) Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range (24-135) dB Sound pressure level in 1/1 octave bands Centre frequency range: (31,5 – 8 000 Hz) Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres (24-135) dB Poziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych: (31,5 – 8 000 Hz) Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 16032:2006","norm_bases":["PN-EN ISO 16032:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C Zakres (24-135) dB Poziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych: (31,5 – 8 000 Hz) Metoda pomiarowa bezpośrednia PN-EN ISO 16032:2006 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas od urzadzen wyposazenia technicznego Rownowazny poziom dzwieku A, C Maksymalny poziom dzwieku A, C Zakres (24-135) dB Poziom cisnienia akustycznego w pasmach 1/1 oktawowych Zakres czestotliwosci srodkowych: (31,5 – 8 000 Hz) Metoda pomiarowa bezposrednia PN-EN ISO 16032:2006","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range (24-135) dB Sound pressure level in 1/1 octave bands Centre frequency range: (31,5 – 8 000 Hz) Direct measurement method PN-EN ISO 16032:2006","search_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声 PN-EN ISO 16032:2006","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声"},{"_id":"6a5a56049af9f73f382547a9","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego","test_object_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment","methodology":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy Znormalizowany równoważny poziom dźwięku A, C dla cyklu pracy Znormalizowany maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","methodology_en":"Reference equivalent A, C sound level for the operating cycle Reference maximum A, C sound level for the operating cycle Standardized equivalent A, C sound level for the operating cycle Standardized maximum A, C sound level for the operating cycle (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy Znormalizowany równoważny poziom dźwięku A, C dla cyklu pracy Znormalizowany maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas od urządzeń wyposażenia technicznego Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy Znormalizowany równoważny poziom dźwięku A, C dla cyklu pracy Znormalizowany maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń) Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas od urzadzen wyposazenia technicznego Wzorcowy rownowazny poziom dzwieku A, C dla cyklu pracy Wzorcowy maksymalny poziom dzwieku A, C dla cyklu pracy Znormalizowany rownowazny poziom dzwieku A, C dla cyklu pracy Znormalizowany maksymalny poziom dzwieku A, C dla cyklu pracy (z obliczen)","categories":["environment","metrology"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public buildings – noise from building service equipment Reference equivalent A, C sound level for the operating cycle Reference maximum A, C sound level for the operating cycle Standardized equivalent A, C sound level for the operating cycle Standardized maximum A, C sound level for the operating cycle (calculated)","search_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 来自技术设备装置的噪声"},{"_id":"6a5a56049af9f73f382547aa","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Obiekty i elementy budowlane","test_object_en":"Construction works and building elements","methodology":"Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz","methodology_en":"Apparent sound reduction index R’ and standardized level difference DnT in 1/1 and 1/3 octave bands. Frequency range of the 1/3 octave centre bands: (50 – 5 000) Hz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz","reference":"PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i elementy budowlane Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06 Obiekty i elementy budowlane Izolacyjnosc akustyczna wlasciwa przyblizona R’ i wzorcowa roznica poziomow DnT w pasmach 1/1 oraz 1/3 oktawowych. Zakres czestotliwosci srodkowych pasm 1/3 oktawowych: (50 – 5 000) Hz PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wylaczeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction works and building elements Apparent sound reduction index R’ and standardized level difference DnT in 1/1 and 1/3 octave bands. Frequency range of the 1/3 octave centre bands: (50 – 5 000) Hz PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","search_zh":"建筑物与建筑构件 PN-EN ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与建筑构件"},{"_id":"6a5a56049af9f73f382547ab","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Obiekty i elementy budowlane","test_object_en":"Construction works and building elements","methodology":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)","methodology_en":"Weighted apparent sound reduction index R’w, and weighted standardized level difference DnT,w, and spectrum adaptation terms C and Ctr (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i elementy budowlane Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń) Obiekty i elementy budowlane Wskaznik wazony izolacyjnosci akustycznej wlasciwej przyblizonej R’w, i wskaznik wazony wzorcowej roznicy poziomow DnT,w, oraz widmowe wskazniki adaptacyjne C i Ctr (z obliczen)","categories":["construction","metrology"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction works and building elements Weighted apparent sound reduction index R’w, and weighted standardized level difference DnT,w, and spectrum adaptation terms C and Ctr (calculated)","methodology_zh":"表观计权隔声量 R’w、计权标准化声压级差 DnT,w 以及频谱修正量 C 与 Ctr（计算得出）","search_zh":"建筑物与建筑构件 表观计权隔声量 R’w、计权标准化声压级差 DnT,w 以及频谱修正量 C 与 Ctr（计算得出）","test_object_zh":"建筑物与建筑构件"},{"_id":"6a5a56049af9f73f382547ac","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Obiekty i elementy budowlane","test_object_en":"Construction works and building elements","methodology":"Czas pogłosu T20 oraz T30 w pasmach 1/1 lub 1/3-oktawowych Zakres częstotliwości środkowych pasm 1/3-oktawowych: (50 – 10 000) Hz Metoda szumu przerywanego","methodology_en":"Reverberation time T20 and T30 in 1/1 or 1/3-octave bands Centre frequency range of 1/3-octave bands: (50 – 10 000) Hz Interrupted noise method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas pogłosu T20 oraz T30 w pasmach 1/1 lub 1/3-oktawowych Zakres częstotliwości środkowych pasm 1/3-oktawowych: (50 – 10 000) Hz Metoda szumu przerywanego","reference":"PN-EN ISO 3382-2:2010","norm_bases":["PN-EN ISO 3382-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i elementy budowlane Czas pogłosu T20 oraz T30 w pasmach 1/1 lub 1/3-oktawowych Zakres częstotliwości środkowych pasm 1/3-oktawowych: (50 – 10 000) Hz Metoda szumu przerywanego PN-EN ISO 3382-2:2010 Obiekty i elementy budowlane Czas poglosu T20 oraz T30 w pasmach 1/1 lub 1/3-oktawowych Zakres czestotliwosci srodkowych pasm 1/3-oktawowych: (50 – 10 000) Hz Metoda szumu przerywanego PN-EN ISO 3382-2:2010","categories":["construction"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction works and building elements Reverberation time T20 and T30 in 1/1 or 1/3-octave bands Centre frequency range of 1/3-octave bands: (50 – 10 000) Hz Interrupted noise method PN-EN ISO 3382-2:2010","search_zh":"建筑物与建筑构件 PN-EN ISO 3382-2:2010","test_object_zh":"建筑物与建筑构件"},{"_id":"6a5a56049af9f73f382547ad","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Obiekty i elementy budowlane","test_object_en":"Construction works and building elements","methodology":"Znormalizowana różnica poziomów Dls,2m,n, wzorcowa różnica poziomów Dls,2m,nT oraz izolacyjność akustyczna przybliżona R`45° w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz, metoda pomiaru terenowego","methodology_en":"Normalized level difference Dls,2m,n, standardized level difference Dls,2m,nT and approximate sound insulation R`45° in 1/1 and 1/3 octave bands. Range of centre frequencies of 1/3 octave bands: (50 – 5 000) Hz, field measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Znormalizowana różnica poziomów Dls,2m,n, wzorcowa różnica poziomów Dls,2m,nT oraz izolacyjność akustyczna przybliżona R`45° w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz, metoda pomiaru terenowego","reference":"PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i elementy budowlane Znormalizowana różnica poziomów Dls,2m,n, wzorcowa różnica poziomów Dls,2m,nT oraz izolacyjność akustyczna przybliżona R`45° w pasmach 1/1 oraz 1/3 oktawowych. Zakres częstotliwości środkowych pasm 1/3 oktawowych: (50 – 5 000) Hz, metoda pomiaru terenowego PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06 Obiekty i elementy budowlane Znormalizowana roznica poziomow Dls,2m,n, wzorcowa roznica poziomow Dls,2m,nT oraz izolacyjnosc akustyczna przyblizona R`45° w pasmach 1/1 oraz 1/3 oktawowych. Zakres czestotliwosci srodkowych pasm 1/3 oktawowych: (50 – 5 000) Hz, metoda pomiaru terenowego PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction works and building elements Normalized level difference Dls,2m,n, standardized level difference Dls,2m,nT and approximate sound insulation R`45° in 1/1 and 1/3 octave bands. Range of centre frequencies of 1/3 octave bands: (50 – 5 000) Hz, field measurement method PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","search_zh":"建筑物与建筑构件 PN-EN ISO 140-5:1999 PN-EN ISO 16283-3:2016-04 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与建筑构件"},{"_id":"6a5a56049af9f73f382547ae","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Obiekty i elementy budowlane","test_object_en":"Construction works and building elements","methodology":"Wskaźnik ważony znormalizowanej różnicy poziomów, wzorcowej różnicy poziomów oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)","methodology_en":"Weighted normalized level difference, standardized level difference and spectrum adaptation terms C and Ctr (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ważony znormalizowanej różnicy poziomów, wzorcowej różnicy poziomów oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i elementy budowlane Wskaźnik ważony znormalizowanej różnicy poziomów, wzorcowej różnicy poziomów oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń) Obiekty i elementy budowlane Wskaznik wazony znormalizowanej roznicy poziomow, wzorcowej roznicy poziomow oraz widmowe wskazniki adaptacyjne C i Ctr (z obliczen)","categories":["construction","metrology"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Construction works and building elements Weighted normalized level difference, standardized level difference and spectrum adaptation terms C and Ctr (calculated)","search_zh":"建筑物与建筑构件","test_object_zh":"建筑物与建筑构件"},{"_id":"6a5a56049af9f73f382547af","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Pomieszczenia w budynkach","test_object_en":"Rooms in buildings","methodology":"Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 80) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia","methodology_en":"RMS value of vibration acceleration in 1/3 octave bands Centre frequencies of 1/3 octave bands: (0,5 – 80) Hz Acceleration range: ±4,9 m/s2 pk Indirect method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 80) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia","reference":"PN-88/B-02171 PN-B-02171:2017-06","norm_bases":["PN-88/B-02171 PN-B-02171:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 80) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia PN-88/B-02171 PN-B-02171:2017-06 Pomieszczenia w budynkach Wartosc skuteczna przyspieszenia drgan w pasmach 1/3 oktawowych Czestotliwosci srodkowe pasm 1/3 oktawowych: (0,5 – 80) Hz Zakres przyspieszen: ±4,9 m/s2 pk Metoda posrednia PN-88/B-02171 PN-B-02171:2017-06","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in buildings RMS value of vibration acceleration in 1/3 octave bands Centre frequencies of 1/3 octave bands: (0,5 – 80) Hz Acceleration range: ±4,9 m/s2 pk Indirect method PN-88/B-02171 PN-B-02171:2017-06","search_zh":"建筑物内的房间 PN-88/B-02171 PN-B-02171:2017-06","test_object_zh":"建筑物内的房间"},{"_id":"6a5a56049af9f73f382547b0","lab_id":"69ad52a3de79e566650fb881","country":"PL","accr_number":"AB 1621","accr_body":"PCA","test_object":"Budynki i budowle","test_object_en":"Buildings and structures","methodology":"Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 100) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia","methodology_en":"Maximum value of vibration acceleration in 1/3 octave bands Centre frequencies of 1/3 octave bands: (0,5 – 100) Hz Acceleration range: ±4,9 m/s2 pk Indirect method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 100) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia","reference":"PN-85/B-02170 PN-B-02170:2016-12","norm_bases":["PN-85/B-02170 PN-B-02170:2016-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Budynki i budowle Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych Częstotliwości środkowe pasm 1/3 oktawowych: (0,5 – 100) Hz Zakres przyspieszeń: ±4,9 m/s2 pk Metoda pośrednia PN-85/B-02170 PN-B-02170:2016-12 Budynki i budowle Wartosc maksymalna przyspieszenia drgan w pasmach 1/3 oktawowych Czestotliwosci srodkowe pasm 1/3 oktawowych: (0,5 – 100) Hz Zakres przyspieszen: ±4,9 m/s2 pk Metoda posrednia PN-85/B-02170 PN-B-02170:2016-12","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Buildings and structures Maximum value of vibration acceleration in 1/3 octave bands Centre frequencies of 1/3 octave bands: (0,5 – 100) Hz Acceleration range: ±4,9 m/s2 pk Indirect method PN-85/B-02170 PN-B-02170:2016-12","search_zh":"建筑物与构筑物 PN-85/B-02170 PN-B-02170:2016-12","test_object_zh":"建筑物与构筑物"}],"has_pdf":true}