{"lab":{"_id":"69ad52a3de79e566650fb879","accr_number":"AB 1617","country":"PL","accr_body":"PCA","address":"Spółka z ograniczoną odpowiedzialnością, Spółka komandytowa, Biała 122 d, 59-225 Chojnów","categories":["environment","construction"],"city":"Chojnów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"dB-lux Laboratorium Środowiska Pracy","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1617.pdf"],"scope_summary":"","search_text":"db-lux laboratorium środowiska pracy spółka z ograniczoną odpowiedzialnością, spółka komandytowa, biała 122 d, 59-225 chojnów environment metrology other materials construction electronics pharma","status":"active","updated_at":"2026-03-08T14:50:45.020Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T09:34:38.766Z","email_confidence":"high","email_mx":true,"email_source":"http://dblux.pl/","parse_date":"2026-08-18T09:34:38.766Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek - środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling – working environment (harmful factors – air)"},{"codes":"G/33, G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, mikroklimat), środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, microclimate), general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek - środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek - środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"issue":{"no":"21","date":"07.08.2026"},"map_coord":[51.272289,15.933524],"map_geo":"nominatim-city","lab_locations":[{"name":"Pracownia Analityczna","address":"Biała 122 d, 59-225 Chojnów","city":"Chojnów","postal":"59-225"},{"name":"Oddział Jelenia Góra","address":"ul. Sudecka 51, pomieszczenie 3/5, 58-500 Jelenia Góra","city":"Jelenia Góra","postal":"58-500"},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","address":null,"city":null,"postal":null},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","address":null,"city":null,"postal":null},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Pracownia Analityczna; Biała 122 d, 59-225 Chojnów","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/18/cc5a02a692684c6083e7c2f1f3a6ead1/AB%201617.pdf","has_en":true,"category_counts":{"environment":39,"construction":4,"materials":2},"category_scores":{"environment":33.8,"construction":0.36,"materials":0.09},"has_zh":true,"lab_locations_zh":[{"name":"Pracownia Analityczna","address":"Biała 122 d, 59-225 Chojnów","city":"Chojnów","postal":"59-225"},{"name":"Oddział Jelenia Góra","address":"ul. Sudecka 51, pomieszczenie 3/5, 58-500 Jelenia Góra","city":"Jelenia Góra","postal":"58-500"},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","address":null,"city":null,"postal":null},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部","address":null,"city":null,"postal":null},{"name":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Pracownia Analityczna; Biała 122 d, 59-225 Chojnów","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a84272e60efa824f4a6bf76","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(44 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(44 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(44 – 138) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(44 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf77","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf78","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(54 – 158) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54 – 158) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54 – 158) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (54 – 158) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(54 – 158) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(54 – 158) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a84272e60efa824f4a6bf79","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 8 小时日工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a84272e60efa824f4a6bf7a","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 105) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 105) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 105) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 105) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 105) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 105) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf7b","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf7c","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,1 – 300) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,1 – 300) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,1 – 300) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf7d","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf7e","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 100) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf7f","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf80","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf81","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf82","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 – 10,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30,0 – 15,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (25,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (25,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotnosc powietrza\nZakres (25,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 – 10,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30,0 – 15,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(25,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 – 10,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(-30,0 – 15,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(25,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf83","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf84","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów dust agents – inhalable fraction – respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 粉尘因素 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"}],"lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf85","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"respirabilne włókna azbestu"},{"name":"respirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne wlokna azbestu\nrespirabilne sztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – respirable fraction – thoracic fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"respirable asbestos fibres"},{"name":"respirable man-made mineral fibres, excluding refractory ceramic fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów organic substances, including – inhalable fraction inorganic substances, including – respirable fraction – thoracic fraction metals and their compounds, including – inhalable fraction – respirable fraction respirable asbestos fibres respirable man-made mineral fibres, excluding refractory ceramic fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 可吸入石棉纤维 呼吸性人造矿物纤维，耐火陶瓷纤维除外 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"有机物质，包括 — 可吸入组分"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"可吸入石棉纤维"},{"name":"呼吸性人造矿物纤维，耐火陶瓷纤维除外"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf86","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf87","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,15 – 40,8) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,15 – 40,8) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,15 – 40,8) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów"},{"_id":"6a84272e60efa824f4a6bf88","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 18,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,09 – 18,6) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,09 – 18,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a84272e60efa824f4a6bf89","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 – 238) mg/m3"},{"name":"Zakres","range":"(2 – 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 – 8,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 – 238) mg/m3\nZakres (2 – 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 – 8,0) ppm\nMetoda elektrochemiczna","reference":"PB-01 wydanie 4 z dnia 16.02.2026 r.","norm_bases":["PB-01 wydanie 4 z dnia 16.02.2026 r."],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów\nZakres:\nCO (2,3 – 238) mg/m3\nZakres (2 – 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 – 8,0) ppm\nMetoda elektrochemiczna PB-01 wydanie 4 z dnia 16.02.2026 r. Srodowisko pracy – powietrze Stezenie gazow\nZakres:\nCO (2,3 – 238) mg/m3\nZakres (2 – 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 – 8,0) ppm\nMetoda elektrochemiczna PB-01 wydanie 4 z dnia 16.02.2026 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 – 238) mg/m3"},{"name":"Range","range":"(2 – 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 – 8,0) ppm"}],"search_en":"Workplace environment – air Gas concentrations Electrochemical method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów CO Range NO (0,3 – 8,0) ppm PB-01 wydanie 4 z dnia 16.02.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"CO","range":"(2,3 – 238) mg/m3"},{"name":"范围","range":"(2 – 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 – 8,0) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度 电化学法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów CO 范围 NO PB-01 wydanie 4 z dnia 16.02.2026 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_zh":"气体浓度"},{"_id":"6a84272e60efa824f4a6bf8a","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,009 – 0,251) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy – powietrze Stezenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_en":"Crystalline silica (quartz, cristobalite) concentration – respirable fraction","parameters_en":[{"name":"Range","range":"(0,009 – 0,251) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Crystalline silica (quartz, cristobalite) concentration – respirable fraction dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów Range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,009 – 0,251) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów 范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Biała 122 d, 59-225 Chojnów","methodology_zh":"结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘"},{"_id":"6a84272e60efa824f4a6bf8b","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(7 – 200) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)"],"computed":[],"activity":"Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres (7 – 200) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Pracownia Analityczna; Biała 122 d, 59-225 Chojnów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres (7 – 200) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres (7 – 200) μg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT- IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Analytical Laboratory; Biała 122 d, 59-225 Chojnów","methodology_en":"Crystalline silica content (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(7 – 200) μg w próbce"}],"search_en":"Workplace environment – air samples collected on filters Crystalline silica content (quartz, cristobalite) – respirable fraction Fourier transform infrared spectrometry (FT- IR) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Analytical Laboratory; Biała 122 d, 59-225 Chojnów Range Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT- IR)","test_object_en":"Workplace environment – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(7 – 200) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a84272e60efa824f4a6bf8c","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(44 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (44 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(44 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(44 – 138) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(44 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf8d","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf8e","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,1 – 300) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,1 – 300) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,1 – 300) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,1 – 300) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf8f","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf90","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+1:2011","norm_bases":["PN-EN 14253+1:2011"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+1:2011","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 100) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range PN-EN 14253+1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 PN-EN 14253+1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf91","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+1:2011","norm_bases":["PN-EN 14253+1:2011"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+1:2011","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch PN-EN 14253+1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 PN-EN 14253+1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf92","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15,0 – 50,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (15,0 – 50,0) 0C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf93","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf94","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 – 10,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30,0 – 15,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (25,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (25,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotnosc powietrza\nZakres (25,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 – 10,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30,0 – 15,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(25,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 – 10,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(-30,0 – 15,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(25,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf95","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf96","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch dust agents – inhalable fraction – respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 粉尘因素 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"}],"lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf97","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"respirabilne włókna azbestu"},{"name":"respirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nrespirabilne wlokna azbestu\nrespirabilne sztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – respirable fraction – thoracic fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"respirable asbestos fibres"},{"name":"respirable man-made mineral fibres, excluding refractory ceramic fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch organic substances, including – inhalable fraction inorganic substances, including – respirable fraction – thoracic fraction metals and their compounds, including – inhalable fraction – respirable fraction respirable asbestos fibres respirable man-made mineral fibres, excluding refractory ceramic fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 可吸入石棉纤维 呼吸性人造矿物纤维，耐火陶瓷纤维除外 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"有机物质，包括 — 可吸入组分"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna – frakcja torakalna"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"可吸入石棉纤维"},{"name":"呼吸性人造矿物纤维，耐火陶瓷纤维除外"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf98","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf99","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,15 – 40,8) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,15 – 40,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,15 – 40,8) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,15 – 40,8) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部"},{"_id":"6a84272e60efa824f4a6bf9a","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 18,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,09 – 18,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,09 – 18,6) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04507:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,09 – 18,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04507:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a84272e60efa824f4a6bf9b","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 - 238) mg/m3"},{"name":"Zakres","range":"(2 - 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 - 8,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 - 238) mg/m3\nZakres (2 - 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 - 8,0) ppm\nMetoda elektrochemiczna","reference":"PB-01 Wydanie 4 z dnia 16.02.2026 r.","norm_bases":["PB-01 Wydanie 4 z dnia 16.02.2026 r."],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów\nZakres:\nCO (2,3 - 238) mg/m3\nZakres (2 - 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 - 8,0) ppm\nMetoda elektrochemiczna PB-01 Wydanie 4 z dnia 16.02.2026 r. Srodowisko pracy – powietrze Stezenie gazow\nZakres:\nCO (2,3 - 238) mg/m3\nZakres (2 - 205) ppm\nNO (0,38 – 10,0) mg/m3\n(0,3 - 8,0) ppm\nMetoda elektrochemiczna PB-01 Wydanie 4 z dnia 16.02.2026 r.","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 - 238) mg/m3"},{"name":"Range","range":"(2 - 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 - 8,0) ppm"}],"search_en":"Workplace environment – air Gas concentrations Electrochemical method dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch CO Range NO (0,3 - 8,0) ppm PB-01 Wydanie 4 z dnia 16.02.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"CO","range":"(2,3 - 238) mg/m3"},{"name":"范围","range":"(2 - 205) ppm"},{"name":"NO","range":"(0,38 – 10,0) mg/m3"},{"name":"(0,3 - 8,0) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度 电化学法 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 CO 范围 NO PB-01 Wydanie 4 z dnia 16.02.2026 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部","methodology_zh":"气体浓度"},{"_id":"6a84272e60efa824f4a6bf9c","lab_id":"69ad52a3de79e566650fb879","country":"PL","accr_number":"AB 1617","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,009 – 0,251) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Oddział Jelenia Góra","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy – powietrze Stezenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,251) mg/m3\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch","methodology_en":"Crystalline silica (quartz, cristobalite) concentration – respirable fraction","parameters_en":[{"name":"Range","range":"(0,009 – 0,251) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Crystalline silica (quartz, cristobalite) concentration – respirable fraction dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.; Jelenia Góra Branch Range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,009 – 0,251) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘 dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部 范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"dB-lux Laboratorium Środowiska Pracy Sp. z o.o. Sp.k.；Jelenia Góra 分部","methodology_zh":"结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘"}],"has_pdf":true}