{"lab":{"_id":"69ad52a3de79e566650fb854","accr_number":"AB 1592","country":"PL","accr_body":"PCA","address":"Laboratorium Oceny Surowca, ul. Przemysłowa 3, 99-400 Łowicz","categories":["food","microbiology"],"city":"Łowicz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":5,"name":"OKRĘGOWA SPÓŁDZIELNIA MLECZARSKA W ŁOWICZU","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1592.pdf"],"scope_summary":"","search_text":"okręgowa spółdzielnia mleczarska w łowiczu laboratorium oceny surowca, ul. przemysłowa 3, 99-400 łowicz food microbiology pharma other","status":"active","updated_at":"2026-03-08T14:50:43.785Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:43.785Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201592,podmiot.html","parse_date":"2026-07-17T16:19:15.910Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"}],"issue":{"no":"9","date":"16.02.2024"},"map_coord":[52.115762,19.954065],"map_geo":"nominatim-street","has_en":true,"category_counts":{"food":5,"microbiology":1},"category_scores":{"food":4.17,"microbiology":0.17},"has_zh":true},"methods":[{"_id":"6a5a56039af9f73f382545f0","lab_id":"69ad52a3de79e566650fb854","country":"PL","accr_number":"AB 1592","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Ogólna liczba drobnoustrojów Zakres: (5 x 103 – 5 x 106) jtk w 1 ml Metoda cytometrii przepływowej","methodology_en":"Total viable count Range: (5 x 103 – 5 x 106) CFU in 1 ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów Zakres: (5 x 103 – 5 x 106) jtk w 1 ml Metoda cytometrii przepływowej","reference":"PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcję producenta aparatu Bactoscan FC","norm_bases":["PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcję producenta aparatu Bactoscan FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów Zakres: (5 x 103 – 5 x 106) jtk w 1 ml Metoda cytometrii przepływowej PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcję producenta aparatu Bactoscan FC Mleko surowe Ogolna liczba drobnoustrojow Zakres: (5 x 103 – 5 x 106) jtk w 1 ml Metoda cytometrii przeplywowej PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcje producenta aparatu Bactoscan FC","categories":["food","microbiology"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Total viable count Range: (5 x 103 – 5 x 106) CFU in 1 ml Flow cytometry method PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcję producenta aparatu Bactoscan FC","search_zh":"生乳 PB-01.00 wydanie 2 z dnia 01.09.2016 r. w oparciu o instrukcję producenta aparatu Bactoscan FC","test_object_zh":"生乳"},{"_id":"6a5a56039af9f73f382545f1","lab_id":"69ad52a3de79e566650fb854","country":"PL","accr_number":"AB 1592","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Liczba komórek somatycznych Zakres: (5 x 104 – 5 x 106) komórek w 1 ml Metoda cytometrii przepływowej","methodology_en":"Somatic cell count Range: (5 x 104 – 5 x 106) cells in 1 ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych Zakres: (5 x 104 – 5 x 106) komórek w 1 ml Metoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Liczba komórek somatycznych Zakres: (5 x 104 – 5 x 106) komórek w 1 ml Metoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP Mleko surowe Liczba komorek somatycznych Zakres: (5 x 104 – 5 x 106) komorek w 1 ml Metoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Somatic cell count Range: (5 x 104 – 5 x 106) cells in 1 ml Flow cytometry method PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP","search_zh":"生乳 PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaScope LFC HP","test_object_zh":"生乳"},{"_id":"6a5a56039af9f73f382545f2","lab_id":"69ad52a3de79e566650fb854","country":"PL","accr_number":"AB 1592","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość tłuszczu, białka Zakres: - dla tłuszczu (1,50 – 5,50) % - dla białka (2,50 – 4,50) % Metoda spektrometrii w podczerwieni","methodology_en":"Content of fat, protein Range: - for fat (1,50 – 5,50) % - for protein (2,50 – 4,50) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tłuszczu, białka Zakres: - dla tłuszczu (1,50 – 5,50) % - dla białka (2,50 – 4,50) % Metoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość tłuszczu, białka Zakres: - dla tłuszczu (1,50 – 5,50) % - dla białka (2,50 – 4,50) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP Mleko surowe Zawartosc tluszczu, bialka Zakres: - dla tluszczu (1,50 – 5,50) % - dla bialka (2,50 – 4,50) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Content of fat, protein Range: - for fat (1,50 – 5,50) % - for protein (2,50 – 4,50) % Infrared spectrometry method PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP","search_zh":"生乳 PN-ISO 9622:2015-09 z zastosowaniem aparatu LactoScope FTIR HP","test_object_zh":"生乳"},{"_id":"6a5a56039af9f73f382545f3","lab_id":"69ad52a3de79e566650fb854","country":"PL","accr_number":"AB 1592","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni","methodology_en":"Urea content Range: (100 – 500) mg/l Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni","reference":"PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","norm_bases":["PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP Mleko surowe Zawartosc mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcje producenta aparatu LactoScope FTIR HP","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Urea content Range: (100 – 500) mg/l Infrared spectrometry method PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","search_zh":"生乳 PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","test_object_zh":"生乳"},{"_id":"6a5a56039af9f73f382545f4","lab_id":"69ad52a3de79e566650fb854","country":"PL","accr_number":"AB 1592","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Temperatura zamarzania Zakres: (-0,200 – -0,600)ºC Metoda spektrometrii w podczerwieni","methodology_en":"Freezing point Range: (-0,200 – -0,600)ºC Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura zamarzania Zakres: (-0,200 – -0,600)ºC Metoda spektrometrii w podczerwieni","reference":"PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","norm_bases":["PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Temperatura zamarzania Zakres: (-0,200 – -0,600)ºC Metoda spektrometrii w podczerwieni PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP Mleko surowe Temperatura zamarzania Zakres: (-0,200 – -0,600)ºC Metoda spektrometrii w podczerwieni PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcje producenta aparatu LactoScope FTIR HP","categories":["food"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Freezing point Range: (-0,200 – -0,600)ºC Infrared spectrometry method PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","search_zh":"生乳 PB-03.00 Wydanie 1 z dnia 02.06.2021 r. w oparciu o instrukcję producenta aparatu LactoScope FTIR HP","test_object_zh":"生乳"}],"has_pdf":true}