{"lab":{"_id":"69ad52a3de79e566650fb850","accr_number":"AB 1590","country":"PL","accr_body":"PCA","address":"ul. Św. Faustyny Kowalskiej 9, 97- 400 Bełchatów, LABORATORIUM, ul. Piotrkowska 110","categories":["water","microbiology"],"city":"","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"ZAKŁAD WODOCIĄGÓW i KANALIZACJI „WOD.-KAN.” Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1590.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji „wod.-kan.” sp. z o.o. ul. św. faustyny kowalskiej 9, 97- 400 bełchatów, laboratorium, ul. piotrkowska 110 microbiology water other pharma electronics automotive","status":"active","updated_at":"2026-03-08T14:50:43.680Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:43.680Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201590,podmiot.html","parse_date":"2026-07-17T16:19:15.874Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"}],"issue":{"no":"10","date":"19.01.2024"},"has_zh":true,"has_en":true,"category_counts":{"water":24,"microbiology":3},"category_scores":{"water":21.33,"microbiology":0.33}},"methods":[{"_id":"6a5a56039af9f73f382545d0","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobierania próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobierania próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobierania próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobierania probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007"},{"_id":"6a5a56039af9f73f382545d1","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobierania próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobierania próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobierania próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobierania probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10"},{"_id":"6a5a56039af9f73f382545d2","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,30 – 20) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,30 – 20) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,30 – 20) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,30 – 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,30 – 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"浊度 范围：(0,30 – 20) NTU 浊度法（散射法）","search_zh":"水 浊度 范围：(0,30 – 20) NTU 浊度法（散射法） PN-EN ISO 7027-1:2016-09","test_object_zh":"水","search_en":"Water Turbidity Range: (0,30 – 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09"},{"_id":"6a5a56039af9f73f382545d3","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda D +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D +Ap1:2015-06 Woda Barwa Zakres: (5 – 70) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 metoda D +Ap1:2015-06","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 目视法","search_zh":"水 色度 范围：(5 – 70) mg/l Pt 目视法 PN-EN ISO 7887:2012 metoda D +Ap1:2015-06","test_object_zh":"水","search_en":"Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 metoda D +Ap1:2015-06"},{"_id":"6a5a56039af9f73f382545d4","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH Zakres: 4,0 – 9,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 9,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 9,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH Zakres: 4,0 – 9,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda pH Zakres: 4,0 – 9,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"pH 值 范围：4,0 – 9,0 电位法","search_zh":"水 pH 值 范围：4,0 – 9,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水","search_en":"Water pH Range: 4,0 – 9,0 Potentiometric method PN-EN ISO 10523:2012"},{"_id":"6a5a56039af9f73f382545d5","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (20 – 1413) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (20 – 1413) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (20 – 1413) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (20 – 1413) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (20 – 1413) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"电导率 范围：(20 – 1413) μS/cm 电导法","search_zh":"水 电导率 范围：(20 – 1413) μS/cm 电导法 PN-EN 27888:1999","test_object_zh":"水","search_en":"Water Electrical conductivity Range: (20 – 1413) μS/cm Conductometric method PN-EN 27888:1999"},{"_id":"6a5a56039af9f73f382545d6","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow Zakres: (5,00 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"氯化物浓度 范围：(5,00 – 300) mg/l 滴定法","search_zh":"水 氯化物浓度 范围：(5,00 – 300) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水","search_en":"Water Chloride concentration Range: (5,00 – 300) mg/l Titrimetric method PN-ISO 9297:1994"},{"_id":"6a5a56039af9f73f382545d7","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego Zakres: (20 – 4000) µg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (20 – 4000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (20 – 4000) µg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego Zakres: (20 – 4000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06 Woda Stezenie zelaza ogolnego Zakres: (20 – 4000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"总铁浓度 范围：(20 – 4000) µg/l 分光光度法","search_zh":"水 总铁浓度 范围：(20 – 4000) µg/l 分光光度法 PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06","test_object_zh":"水","search_en":"Water Total iron concentration Range: (20 – 4000) µg/l Spectrophotometric method PN-ISO 6332:2001 pkt. 7.1.1 PN-ISO 6332:2001/Ap1:2016-06"},{"_id":"6a5a56039af9f73f382545d8","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego Zakres: (0,130 – 2,60) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,130 – 2,60) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,130 – 2,60) mg/l Metoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego Zakres: (0,130 – 2,60) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994 Woda Stezenie jonu amonowego Zakres: (0,130 – 2,60) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"铵离子浓度 范围：(0,130 – 2,60) mg/l 分光光度法","search_zh":"水 铵离子浓度 范围：(0,130 – 2,60) mg/l 分光光度法 PN-C-04576-4:1994","test_object_zh":"水","search_en":"Water Ammonium ion concentration Range: (0,130 – 2,60) mg/l Spectrophotometric method PN-C-04576-4:1994"},{"_id":"6a5a56039af9f73f382545d9","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów Zakres: (0,010 – 0,66) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,010 – 0,66) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,010 – 0,66) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów Zakres: (0,010 – 0,66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow Zakres: (0,010 – 0,66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"亚硝酸盐浓度 范围：(0,010 – 0,66) mg/l 分光光度法","search_zh":"水 亚硝酸盐浓度 范围：(0,010 – 0,66) mg/l 分光光度法 PN-EN 26777:1999","test_object_zh":"水","search_en":"Water Nitrite concentration Range: (0,010 – 0,66) mg/l Spectrophotometric method PN-EN 26777:1999"},{"_id":"6a5a56039af9f73f382545da","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (15 – 400) µg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (15 – 400) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (15 – 400) µg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (15 – 400) µg/l Metoda spektrofotometryczna PN-92/C-04590/03 Woda Stezenie manganu Zakres: (15 – 400) µg/l Metoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"锰浓度 范围：(15 – 400) µg/l 分光光度法","search_zh":"水 锰浓度 范围：(15 – 400) µg/l 分光光度法 PN-92/C-04590/03","test_object_zh":"水","search_en":"Water Manganese concentration Range: (15 – 400) µg/l Spectrophotometric method PN-92/C-04590/03"},{"_id":"6a5a56039af9f73f382545db","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 22ºC Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 22ºC Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22ºC Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 22ºC Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22ºC Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"22 °C 微生物总数 平板法（倾注培养）","search_zh":"水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","test_object_zh":"水","search_en":"Water Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004"},{"_id":"6a5a56039af9f73f382545dc","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 36ºC Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 36ºC Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36ºC Metoda płytkowa (posiew wgłębny)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 36ºC Metoda płytkowa (posiew wgłębny) Woda Ogolna liczba mikroorganizmow w 36ºC Metoda plytkowa (posiew wglebny)","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"36 °C 微生物总数 平板法（倾注培养）","search_zh":"水 36 °C 微生物总数 平板法（倾注培养）","test_object_zh":"水","search_en":"Water Total count of microorganisms at 36ºC Plate method (pour plate)"},{"_id":"6a5a56039af9f73f382545dd","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12 +A1:2017-04"},{"_id":"6a5a56039af9f73f382545de","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli Metoda filtracji membranowej Woda Liczba bakterii grupy coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水 大肠菌群计数 膜过滤法","test_object_zh":"水","search_en":"Water Coliform bacteria count Membrane filtration method"},{"_id":"6a5a56039af9f73f382545df","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba Enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"粪肠球菌计数 膜过滤法","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004"},{"_id":"6a5a56039af9f73f382545e0","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"化学与物理检测用样品采集 手动法 自动法","search_zh":"污水 化学与物理检测用样品采集 手动法 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11"},{"_id":"6a5a56039af9f73f382545e1","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: 4,0 – 9,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 9,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 9,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: 4,0 – 9,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: 4,0 – 9,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"pH 值 范围：4,0 – 9,0 电位法","search_zh":"污水 pH 值 范围：4,0 – 9,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","search_en":"Wastewater pH Range: 4,0 – 9,0 Potentiometric method PN-EN ISO 10523:2012"},{"_id":"6a5a56039af9f73f382545e2","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Cr Zakres: (30,0 – 10000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD Cr Range: (30,0 – 10000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Cr Zakres: (30,0 – 10000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT Cr Zakres: (30,0 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT Cr Zakres: (30,0 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"化学需氧量 ChZT-Cr（CODCr） 范围：(30,0 – 10000) mg/l O2 分光光度法","search_zh":"污水 化学需氧量 ChZT-Cr（CODCr） 范围：(30,0 – 10000) mg/l O2 分光光度法 PN-ISO 15705:2005","test_object_zh":"污水","search_en":"Wastewater Chemical oxygen demand - COD Cr Range: (30,0 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005"},{"_id":"6a5a56039af9f73f382545e3","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"生化需氧量 BZT5（BOD5） 范围：(1 – 6000) mg/l O2 电化学法","search_zh":"污水 生化需氧量 BZT5（BOD5） 范围：(1 – 6000) mg/l O2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12"},{"_id":"6a5a56039af9f73f382545e4","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"总悬浮物 范围：(5,0 – 2000) mg/l 重量法","search_zh":"污水 总悬浮物 范围：(5,0 – 2000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水","search_en":"Wastewater Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007"},{"_id":"6a5a56039af9f73f382545e5","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5,00 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5,00 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"氯化物浓度 范围：(5,00 – 300) mg/l 滴定法","search_zh":"污水 氯化物浓度 范围：(5,00 – 300) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"污水","search_en":"Wastewater Chloride concentration Range: (5,00 – 300) mg/l Titrimetric method PN-ISO 9297:1994"},{"_id":"6a5a56039af9f73f382545e6","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,080 – 30,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,080 – 30,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,080 – 30,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,080 – 30,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,080 – 30,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"总磷浓度 范围：(0,080 – 30,0) mg/l 分光光度法","search_zh":"污水 总磷浓度 范围：(0,080 – 30,0) mg/l 分光光度法 PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","test_object_zh":"污水","search_en":"Wastewater Total phosphorus concentration Range: (0,080 – 30,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010"},{"_id":"6a5a56039af9f73f382545e7","lab_id":"69ad52a3de79e566650fb850","country":"PL","accr_number":"AB 1590","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,080 – 30,0) mg/l P Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,080 – 30,0) mg/l P Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,080 – 30,0) mg/l P Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ortofosforanów Zakres: (0,080 – 30,0) mg/l P Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010 Scieki Stezenie ortofosforanow Zakres: (0,080 – 30,0) mg/l P Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"正磷酸盐浓度 范围：(0,080 – 30,0) mg/l P 分光光度法","search_zh":"污水 正磷酸盐浓度 范围：(0,080 – 30,0) mg/l P 分光光度法 PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","test_object_zh":"污水","search_en":"Wastewater Orthophosphate concentration Range: (0,080 – 30,0) mg/l P Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"}],"has_pdf":true}