{"lab":{"_id":"69ad52a3de79e566650fb840","accr_number":"AB 1578","country":"PL","accr_body":"PCA","address":"Laboratorium Oceny Surowca, ul. Ogrodowa 17, 08-410 Wola Rębkowska","categories":["food","microbiology"],"city":"Wola Rębkowska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"OKRĘGOWA SPÓŁDZIELNIA MLECZARSKA GARWOLIN","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1578.pdf"],"scope_summary":"","search_text":"okręgowa spółdzielnia mleczarska garwolin laboratorium oceny surowca, ul. ogrodowa 17, 08-410 wola rębkowska food microbiology pharma","status":"active","updated_at":"2026-03-08T14:50:43.190Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:43.190Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201578,podmiot.html","parse_date":"2026-07-17T16:19:15.557Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"B/22","pl":"Badania biologiczne i biochemiczne żywności","en":"Biological and biochemical tests of food","de":"Biologische und biochemische Prüfungen von Lebensmitteln","zh":"食品的生物和生化检测","cs":"Biologické a biochemické zkoušky potravin"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food","de":"Chemische Prüfungen von Lebensmitteln","zh":"食品化学检测","cs":"Chemické zkoušky potravin"},{"codes":"K/ 22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food","de":"Mikrobiologische Prüfungen von Lebensmitteln","zh":"食品微生物检测","cs":"Mikrobiologické zkoušky potravin"}],"map_coord":[51.897356,21.554354],"map_geo":"nominatim-street","has_en":true,"category_counts":{"food":4,"microbiology":1},"category_scores":{"food":3.2,"microbiology":0.2},"has_zh":true,"has_de":true,"has_cs":true,"pelny_cs":true},"methods":[{"_id":"6a5a56039af9f73f3825452f","lab_id":"69ad52a3de79e566650fb840","country":"PL","accr_number":"AB 1578","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Ogólna liczba drobnoustrojów Zakres: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda cytometrii przepływowej","methodology_en":"Total viable count Range: (1,0 x 103 – 3,0 x 106) CFU/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów Zakres: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda cytometrii przepływowej","reference":"PB-01 wydanie 2 z dnia 18.05.2022 r. w oparciu o instrukcję aparatu BactoScan FC","norm_bases":["PB-01 wydanie 2 z dnia 18.05.2022 r. w oparciu o instrukcję aparatu BactoScan FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Ogólna liczba drobnoustrojów Zakres: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda cytometrii przepływowej PB-01 wydanie 2 z dnia 18.05.2022 r. w oparciu o instrukcję aparatu BactoScan FC Mleko surowe krowie Ogolna liczba drobnoustrojow Zakres: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda cytometrii przeplywowej PB-01 wydanie 2 z dnia 18.05.2022 r. w oparciu o instrukcje aparatu BactoScan FC","categories":["food","microbiology"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Total viable count Range: (1,0 x 103 – 3,0 x 106) CFU/ml Flow cytometry method PB-01 issue 2 of 18.05.2022 based on the instructions for the BactoScan FC instrument","search_zh":"生鲜牛乳 微生物总数 范围：(1,0 x 103 – 3,0 x 106) CFU/ml 流式细胞术 PB-01 第2版（2022年5月18日）依据BactoScan FC仪器说明书","test_object_zh":"生鲜牛乳","methodology_de":"Gesamtkeimzahl Bereich: (1,0 x 103 – 3,0 x 106) KBE/ml Durchflusszytometrisches Verfahren","search_de":"Kuhrohmilch Gesamtkeimzahl Bereich: (1,0 x 103 – 3,0 x 106) KBE/ml Durchflusszytometrisches Verfahren PB-01 Ausgabe 2 vom 18.05.2022 auf Grundlage der Anleitung des Geräts BactoScan FC","test_object_de":"Kuhrohmilch","methodology_zh":"微生物总数 范围：(1,0 x 103 – 3,0 x 106) CFU/ml 流式细胞术","reference_en":"PB-01 issue 2 of 18.05.2022 based on the instructions for the BactoScan FC instrument","reference_de":"PB-01 Ausgabe 2 vom 18.05.2022 auf Grundlage der Anleitung des Geräts BactoScan FC","reference_zh":"PB-01 第2版（2022年5月18日）依据BactoScan FC仪器说明书","search_cs":"Syrové kravské mléko Celkový počet mikroorganismů Rozsah: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda průtokové cytometrie PB-01 vydání 2 ze dne 18.05.2022 na základě návodu k přístroji BactoScan FC","test_object_cs":"Syrové kravské mléko","methodology_cs":"Celkový počet mikroorganismů Rozsah: (1,0 x 103 – 3,0 x 106) CFU/ml Metoda průtokové cytometrie","reference_cs":"PB-01 vydání 2 ze dne 18.05.2022 na základě návodu k přístroji BactoScan FC"},{"_id":"6a5a56039af9f73f38254530","lab_id":"69ad52a3de79e566650fb840","country":"PL","accr_number":"AB 1578","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Liczba komórek somatycznych Zakres: (7,0 x 103 – 2,0 x 106) komórek/ml Metoda cytometrii przepływowej","methodology_en":"Somatic cell count Range: (7,0 x 103 – 2,0 x 106) cells/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych Zakres: (7,0 x 103 – 2,0 x 106) komórek/ml Metoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Liczba komórek somatycznych Zakres: (7,0 x 103 – 2,0 x 106) komórek/ml Metoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000 Mleko surowe krowie Liczba komorek somatycznych Zakres: (7,0 x 103 – 2,0 x 106) komorek/ml Metoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Somatic cell count Range: (7,0 x 103 – 2,0 x 106) cells/ml Flow cytometry method PN-EN ISO 13366-2:2007 using the Fossomatic 5000 instrument","search_zh":"生鲜牛乳 体细胞计数 范围：(7,0 x 103 – 2,0 x 106) 细胞/ml 流式细胞术 PN-EN ISO 13366-2:2007 使用Fossomatic 5000仪器","test_object_zh":"生鲜牛乳","methodology_de":"Somatische Zellzahl Bereich: (7,0 x 103 – 2,0 x 106) Zellen/ml Durchflusszytometrisches Verfahren","search_de":"Kuhrohmilch Somatische Zellzahl Bereich: (7,0 x 103 – 2,0 x 106) Zellen/ml Durchflusszytometrisches Verfahren PN-EN ISO 13366-2:2007 unter Verwendung des Geräts Fossomatic 5000","test_object_de":"Kuhrohmilch","methodology_zh":"体细胞计数 范围：(7,0 x 103 – 2,0 x 106) 细胞/ml 流式细胞术","reference_en":"PN-EN ISO 13366-2:2007 using the Fossomatic 5000 instrument","reference_de":"PN-EN ISO 13366-2:2007 unter Verwendung des Geräts Fossomatic 5000","reference_zh":"PN-EN ISO 13366-2:2007 使用Fossomatic 5000仪器","search_cs":"Syrové kravské mléko Počet somatických buněk Rozsah: (7,0 x 103 – 2,0 x 106) buněk/ml Metoda průtokové cytometrie PN-EN ISO 13366-2:2007 s použitím přístroje Fossomatic 5000","test_object_cs":"Syrové kravské mléko","methodology_cs":"Počet somatických buněk Rozsah: (7,0 x 103 – 2,0 x 106) buněk/ml Metoda průtokové cytometrie","reference_cs":"PN-EN ISO 13366-2:2007 s použitím přístroje Fossomatic 5000"},{"_id":"6a5a56039af9f73f38254531","lab_id":"69ad52a3de79e566650fb840","country":"PL","accr_number":"AB 1578","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Zawartość tłuszczu Zakres: (1,50 – 6,50) % Metoda spektrometrii w podczerwieni","methodology_en":"Fat content Range: (1,50 – 6,50) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tłuszczu Zakres: (1,50 – 6,50) % Metoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Zawartość tłuszczu Zakres: (1,50 – 6,50) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000 Mleko surowe krowie Zawartosc tluszczu Zakres: (1,50 – 6,50) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Fat content Range: (1,50 – 6,50) % Infrared spectrometry method PN-ISO 9622:2015-09 using the Milkoscan 4000 instrument","search_zh":"生鲜牛乳 脂肪含量 范围：(1,50 – 6,50) % 红外光谱法 PN-ISO 9622:2015-09 使用Milkoscan 4000仪器","test_object_zh":"生鲜牛乳","methodology_de":"Fettgehalt Bereich: (1,50 – 6,50) % Infrarotspektrometrie","search_de":"Kuhrohmilch Fettgehalt Bereich: (1,50 – 6,50) % Infrarotspektrometrie PN-ISO 9622:2015-09 unter Verwendung des Geräts Milkoscan 4000","test_object_de":"Kuhrohmilch","methodology_zh":"脂肪含量 范围：(1,50 – 6,50) % 红外光谱法","reference_en":"PN-ISO 9622:2015-09 using the Milkoscan 4000 instrument","reference_de":"PN-ISO 9622:2015-09 unter Verwendung des Geräts Milkoscan 4000","reference_zh":"PN-ISO 9622:2015-09 使用Milkoscan 4000仪器","search_cs":"Syrové kravské mléko Obsah tuku Rozsah: (1,50 – 6,50) % Metoda infračervené spektrometrie PN-ISO 9622:2015-09 s použitím přístroje Milkoscan 4000","test_object_cs":"Syrové kravské mléko","methodology_cs":"Obsah tuku Rozsah: (1,50 – 6,50) % Metoda infračervené spektrometrie","reference_cs":"PN-ISO 9622:2015-09 s použitím přístroje Milkoscan 4000"},{"_id":"6a5a56039af9f73f38254532","lab_id":"69ad52a3de79e566650fb840","country":"PL","accr_number":"AB 1578","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Zawartość białka Zakres: (2,00 – 5,00) % Metoda spektrometrii w podczerwieni","methodology_en":"Protein content Range: (2,00 – 5,00) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość białka Zakres: (2,00 – 5,00) % Metoda spektrometrii w podczerwieni","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Zawartość białka Zakres: (2,00 – 5,00) % Metoda spektrometrii w podczerwieni Mleko surowe krowie Zawartosc bialka Zakres: (2,00 – 5,00) % Metoda spektrometrii w podczerwieni","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Protein content Range: (2,00 – 5,00) % Infrared spectrometry method","search_zh":"生鲜牛乳 蛋白质含量 范围：(2,00 – 5,00) % 红外光谱法","test_object_zh":"生鲜牛乳","methodology_de":"Proteingehalt Bereich: (2,00 – 5,00) % Infrarotspektrometrie","search_de":"Kuhrohmilch Proteingehalt Bereich: (2,00 – 5,00) % Infrarotspektrometrie","test_object_de":"Kuhrohmilch","methodology_zh":"蛋白质含量 范围：(2,00 – 5,00) % 红外光谱法","search_cs":"Syrové kravské mléko Obsah bílkovin Rozsah: (2,00 – 5,00) % Metoda infračervené spektrometrie","test_object_cs":"Syrové kravské mléko","methodology_cs":"Obsah bílkovin Rozsah: (2,00 – 5,00) % Metoda infračervené spektrometrie"}],"has_pdf":true}