{"lab":{"_id":"69ad52a3de79e566650fb83e","accr_number":"AB 1577","country":"PL","accr_body":"PCA","address":"ZAKŁAD NAUKOWY - CENTRUM RADIOBIOLOGII I DOZYMETRII BIOLOGICZNEJ, ul. Dorodna 16, 03-195 Warszawa","categories":["other"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":1,"name":"INSTYTUT CHEMII I TECHNIKI JĄDROWEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1577.pdf"],"scope_summary":"","search_text":"instytut chemii i techniki jądrowej zakład naukowy - centrum radiobiologii i dozymetrii biologicznej, ul. dorodna 16, 03-195 warszawa other","status":"active","updated_at":"2026-03-08T14:50:43.143Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:43.143Z","email_confidence":"high","email_mx":true,"email_source":"https://rapid.ichtj.waw.pl/kontakt/","parse_date":"2026-07-17T16:19:15.549Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"O/3","pl":"Badania radiochemiczne i promieniowania – w tym nuklearne w obiektach i materiałach biologicznych przeznaczonych do badań","en":"Radiochemical tests and tests of radiation – including nuclear radiation in the biological items and materials for testing"}],"issue":{"no":"6","date":"09.08.2024"},"map_coord":[52.301186,20.980767],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":1},"category_scores":{"other":1}},"methods":[{"_id":"6a5a56039af9f73f3825452e","lab_id":"69ad52a3de79e566650fb83e","country":"PL","accr_number":"AB 1577","accr_body":"PCA","test_object":"Limfocyty krwi obwodowej człowieka","test_object_en":"Human peripheral blood lymphocytes","methodology":"Dawka pochłonięta promieniowania gamma 60Co i promieniowania X o energii 200 keV na podstawie oceny częstości występowania chromosomów dicentrycznych Zakres: 0,2 Gy – 4 Gy. Metoda cytogenetycznej dozymetrii biologicznej","methodology_en":"Absorbed dose of 60Co gamma radiation and of X radiation with an energy of 200 keV based on the assessment of the frequency of dicentric chromosomes Range: 0,2 Gy – 4 Gy. Cytogenetic biological dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co i promieniowania X o energii 200 keV na podstawie oceny częstości występowania chromosomów dicentrycznych Zakres: 0,2 Gy – 4 Gy. Metoda cytogenetycznej dozymetrii biologicznej","reference":"PN-EN ISO 19238:2017-02 Procedura badawcza PB-1","norm_bases":["PN-EN ISO 19238:2017-02 Procedura badawcza PB-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Limfocyty krwi obwodowej człowieka Dawka pochłonięta promieniowania gamma 60Co i promieniowania X o energii 200 keV na podstawie oceny częstości występowania chromosomów dicentrycznych Zakres: 0,2 Gy – 4 Gy. Metoda cytogenetycznej dozymetrii biologicznej PN-EN ISO 19238:2017-02 Procedura badawcza PB-1 Limfocyty krwi obwodowej czlowieka Dawka pochlonieta promieniowania gamma 60Co i promieniowania X o energii 200 keV na podstawie oceny czestosci wystepowania chromosomow dicentrycznych Zakres: 0,2 Gy – 4 Gy. Metoda cytogenetycznej dozymetrii biologicznej PN-EN ISO 19238:2017-02 Procedura badawcza PB-1","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Human peripheral blood lymphocytes Absorbed dose of 60Co gamma radiation and of X radiation with an energy of 200 keV based on the assessment of the frequency of dicentric chromosomes Range: 0,2 Gy – 4 Gy. Cytogenetic biological dosimetry method PN-EN ISO 19238:2017-02 Procedura badawcza PB-1"}],"has_pdf":true}