{"lab":{"_id":"69ad52a3de79e566650fb81e","accr_number":"AB 1555","country":"PL","accr_body":"PCA","address":"LABORATORIUM BEMC, ul. Przemysłowa 75; 32-765 Rzezawa","categories":["environment","electronics"],"city":"Rzezawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":38,"name":"„MAWI” Spółka z Ograniczoną Odpowiedzialnością","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1555.pdf"],"scope_summary":"","search_text":"„mawi” spółka z ograniczoną odpowiedzialnością laboratorium bemc, ul. przemysłowa 75; 32-765 rzezawa environment other pharma electronics metrology construction","status":"active","updated_at":"2026-03-08T14:50:42.069Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:01:39.406Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201555,podmiot.html","parse_date":"2026-08-13T08:01:39.406Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"F/6; F/14; F/53; F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, telekomunikacyjnego, elektronicznego i wyposażenia medycznego","en":"Electromagnetic compatibility (EMC) tests of electrical, telecommunication and electronic products and medical equipment"},{"codes":"E/6; E/14; E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, elektronicznego i wyposażenia medycznego","en":"Electric and electronic tests of electrical, electronic products and medical equipment"}],"issue":{"no":"16","date":"13.02.2026"},"map_coord":[50.006141,20.51255],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BEMC","address":"ul. Przemysłowa 75; 32-765 Rzezawa","city":"Rzezawa","postal":"32-765"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/6bfb5cf511fbbac1c37ffd0f1521bb21/AB%201555.pdf","has_en":true,"category_counts":{"other":17,"environment":11,"electronics":10,"construction":1},"category_scores":{"other":7.41,"environment":3.1,"electronics":2.56,"construction":0.03},"has_zh":true},"methods":[{"_id":"6a7d79e30636ba417e41af5c","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","methodology":"Emisja zaburzeń promieniowanych","parameters":[{"name":"Zakres","range":"9 kHz - 6 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016/A1:2017-06 | PN-EN 55011:2016/A11:2020-07 | PN-EN 55011:2016/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016/A1:2017-06","PN-EN 55011:2016/A11:2020-07","PN-EN 55011:2016/A2:2021-08"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55011:2016-05 | PN-EN 55011:2016/A1:2017-06 | PN-EN 55011:2016/A11:2020-07 | PN-EN 55011:2016/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne Emisja zaburzen promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55011:2016-05 | PN-EN 55011:2016/A1:2017-06 | PN-EN 55011:2016/A11:2020-07 | PN-EN 55011:2016/A2:2021-08","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Radiated disturbance emission","parameters_en":[{"name":"Range","range":"9 kHz - 6 GHz"}],"search_en":"Industrial, scientific and medical equipment Radiated disturbance emission BEMC Laboratory Range PN-EN 55011:2016-05 | PN-EN 55011:2016/A1:2017-06 | PN-EN 55011:2016/A11:2020-07 | PN-EN 55011:2016/A2:2021-08","test_object_en":"Industrial, scientific and medical equipment","parameters_zh":[{"name":"范围","range":"9 kHz - 6 GHz"}],"search_zh":"工业、科学与医疗设备 辐射骚扰发射 BEMC 实验室 范围 PN-EN 55011:2016-05 | PN-EN 55011:2016/A1:2017-06 | PN-EN 55011:2016/A11:2020-07 | PN-EN 55011:2016/A2:2021-08","lab_section_zh":"BEMC 实验室","test_object_zh":"工业、科学与医疗设备","methodology_zh":"辐射骚扰发射"},{"_id":"6a7d79e30636ba417e41af5d","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń promieniowanych","parameters":[{"name":"Zakres","range":"9 kHz - 6 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz","reference":"PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","norm_bases":["PN-EN 55014-1:2017-06","PN-EN IEC 55014-1:2021-08"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Radiated disturbance emission","parameters_en":[{"name":"Range","range":"9 kHz - 6 GHz"}],"search_en":"Household appliances, electric tools and similar apparatus Radiated disturbance emission BEMC Laboratory Range PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","test_object_en":"Household appliances, electric tools and similar apparatus","parameters_zh":[{"name":"范围","range":"9 kHz - 6 GHz"}],"search_zh":"家用器具、电动工具及类似设备 辐射骚扰发射 BEMC 实验室 范围 PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","lab_section_zh":"BEMC 实验室","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"辐射骚扰发射"},{"_id":"6a7d79e30636ba417e41af5e","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Aparatura pomiarowa","methodology":"Emisja zaburzeń promieniowanych","parameters":[{"name":"Zakres","range":"9 kHz - 6 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017/ A1:2020-01","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017/ A1:2020-01"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Aparatura pomiarowa Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017/ A1:2020-01 Aparatura pomiarowa Emisja zaburzen promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017/ A1:2020-01","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Radiated disturbance emission","parameters_en":[{"name":"Range","range":"9 kHz - 6 GHz"}],"search_en":"Measuring apparatus Radiated disturbance emission BEMC Laboratory Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017/ A1:2020-01","test_object_en":"Measuring apparatus","parameters_zh":[{"name":"范围","range":"9 kHz - 6 GHz"}],"search_zh":"辐射骚扰发射 BEMC 实验室 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017/ A1:2020-01","lab_section_zh":"BEMC 实验室","methodology_zh":"辐射骚扰发射"},{"_id":"6a7d79e30636ba417e41af5f","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Emisja zaburzeń promieniowanych","parameters":[{"name":"Zakres","range":"9 kHz - 6 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Emisja zaburzen promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Radiated disturbance emission","parameters_en":[{"name":"Range","range":"9 kHz - 6 GHz"}],"search_en":"Medical electrical equipment Radiated disturbance emission BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"9 kHz - 6 GHz"}],"search_zh":"医用电气设备 辐射骚扰发射 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","test_object_zh":"医用电气设备","methodology_zh":"辐射骚扰发射"},{"_id":"6a7d79e30636ba417e41af60","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Emisja zaburzeń promieniowanych","parameters":[{"name":"Zakres","range":"9 kHz - 6 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11-2020-07","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013/A1:2015-08","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019/A11-2020-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Emisja zaburzeń promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55015:2013-10 | PN-EN 55015:2013/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11-2020-07 Sprzet oswietleniowy Emisja zaburzen promieniowanych\nZakres 9 kHz - 6 GHz PN-EN 55015:2013-10 | PN-EN 55015:2013/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11-2020-07","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Radiated disturbance emission","parameters_en":[{"name":"Range","range":"9 kHz - 6 GHz"}],"search_en":"Lighting equipment Radiated disturbance emission BEMC Laboratory Range PN-EN 55015:2013-10 | PN-EN 55015:2013/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11-2020-07","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"9 kHz - 6 GHz"}],"search_zh":"照明器材 辐射骚扰发射 BEMC 实验室 范围 PN-EN 55015:2013-10 | PN-EN 55015:2013/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11-2020-07","lab_section_zh":"BEMC 实验室","methodology_zh":"辐射骚扰发射","test_object_zh":"照明器材"},{"_id":"6a7d79e30636ba417e41af61","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","methodology":"Emisja zaburzeń przewodzonych – napięcie zaburzeń","parameters":[{"name":"Zakres","range":"9 kHz – 30 MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne Emisja zaburzen przewodzonych – napiecie zaburzen\nZakres 9 kHz – 30 MHz PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Conducted disturbance emission – disturbance voltage","parameters_en":[{"name":"Range","range":"9 kHz – 30 MHz"}],"search_en":"Industrial, scientific and medical equipment Conducted disturbance emission – disturbance voltage BEMC Laboratory Range PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_en":"Industrial, scientific and medical equipment","parameters_zh":[{"name":"范围","range":"9 kHz – 30 MHz"}],"search_zh":"工业、科学与医疗设备 传导骚扰发射 － 骚扰电压 BEMC 实验室 范围 PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","lab_section_zh":"BEMC 实验室","test_object_zh":"工业、科学与医疗设备","methodology_zh":"传导骚扰发射 － 骚扰电压"},{"_id":"6a7d79e30636ba417e41af62","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń przewodzonych – napięcie zaburzeń","parameters":[{"name":"Zakres","range":"9 kHz – 30 MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz","reference":"PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","norm_bases":["PN-EN 55014-1:2017-06","PN-EN IEC 55014-1:2021-08"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen przewodzonych – napiecie zaburzen\nZakres 9 kHz – 30 MHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Conducted disturbance emission – disturbance voltage","parameters_en":[{"name":"Range","range":"9 kHz – 30 MHz"}],"search_en":"Household appliances, electric tools and similar apparatus Conducted disturbance emission – disturbance voltage BEMC Laboratory Range PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","test_object_en":"Household appliances, electric tools and similar apparatus","parameters_zh":[{"name":"范围","range":"9 kHz – 30 MHz"}],"search_zh":"家用器具、电动工具及类似设备 传导骚扰发射 － 骚扰电压 BEMC 实验室 范围 PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08","lab_section_zh":"BEMC 实验室","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"传导骚扰发射 － 骚扰电压"},{"_id":"6a7d79e30636ba417e41af63","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Aparatura pomiarowa","methodology":"Emisja zaburzeń przewodzonych – napięcie zaburzeń","parameters":[{"name":"Zakres","range":"9 kHz – 30 MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz","reference":"PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014/A1:2017-12 | PN-EN 55016-2-1:2014/AC:2020-11","norm_bases":["PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014/A1:2017-12","PN-EN 55016-2-1:2014/AC:2020-11"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Aparatura pomiarowa Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014/A1:2017-12 | PN-EN 55016-2-1:2014/AC:2020-11 Aparatura pomiarowa Emisja zaburzen przewodzonych – napiecie zaburzen\nZakres 9 kHz – 30 MHz PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014/A1:2017-12 | PN-EN 55016-2-1:2014/AC:2020-11","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Conducted disturbance emission – disturbance voltage","parameters_en":[{"name":"Range","range":"9 kHz – 30 MHz"}],"search_en":"Measuring apparatus Conducted disturbance emission – disturbance voltage BEMC Laboratory Range PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014/A1:2017-12 | PN-EN 55016-2-1:2014/AC:2020-11","test_object_en":"Measuring apparatus","parameters_zh":[{"name":"范围","range":"9 kHz – 30 MHz"}],"search_zh":"传导骚扰发射 － 骚扰电压 BEMC 实验室 范围 PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014/A1:2017-12 | PN-EN 55016-2-1:2014/AC:2020-11","lab_section_zh":"BEMC 实验室","methodology_zh":"传导骚扰发射 － 骚扰电压"},{"_id":"6a7d79e30636ba417e41af64","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Emisja zaburzeń przewodzonych – napięcie zaburzeń","parameters":[{"name":"Zakres","range":"9 kHz – 30 MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Emisja zaburzen przewodzonych – napiecie zaburzen\nZakres 9 kHz – 30 MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Conducted disturbance emission – disturbance voltage","parameters_en":[{"name":"Range","range":"9 kHz – 30 MHz"}],"search_en":"Medical electrical equipment Conducted disturbance emission – disturbance voltage BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"9 kHz – 30 MHz"}],"search_zh":"医用电气设备 传导骚扰发射 － 骚扰电压 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","test_object_zh":"医用电气设备","methodology_zh":"传导骚扰发射 － 骚扰电压"},{"_id":"6a7d79e30636ba417e41af65","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Emisja zaburzeń przewodzonych – napięcie zaburzeń","parameters":[{"name":"Zakres","range":"9 kHz – 30 MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11:2020-07","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013-10/A1:2015-08","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019/A11:2020-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Emisja zaburzeń przewodzonych – napięcie zaburzeń\nZakres 9 kHz – 30 MHz PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11:2020-07 Sprzet oswietleniowy Emisja zaburzen przewodzonych – napiecie zaburzen\nZakres 9 kHz – 30 MHz PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11:2020-07","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Conducted disturbance emission – disturbance voltage","parameters_en":[{"name":"Range","range":"9 kHz – 30 MHz"}],"search_en":"Lighting equipment Conducted disturbance emission – disturbance voltage BEMC Laboratory Range PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11:2020-07","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"9 kHz – 30 MHz"}],"search_zh":"照明器材 传导骚扰发射 － 骚扰电压 BEMC 实验室 范围 PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019/A11:2020-07","lab_section_zh":"BEMC 实验室","test_object_zh":"照明器材","methodology_zh":"传导骚扰发射 － 骚扰电压"},{"_id":"6a7d79e30636ba417e41af66","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","reference":"PN-EN 61000-3-3:2013:10 | PN-EN 61000-3-3:2013/A1:2019-10 | PN-EN 61000-3-3:2013/A2:2022-04","norm_bases":["PN-EN 61000-3-3:2013:10","PN-EN 61000-3-3:2013/A1:2019-10","PN-EN 61000-3-3:2013/A2:2022-04"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia PN-EN 61000-3-3:2013:10 | PN-EN 61000-3-3:2013/A1:2019-10 | PN-EN 61000-3-3:2013/A2:2022-04 Urzadzenia elektryczne i elektroniczne Zmiany napiecia, wahania napiecia i migotania swiatla w publicznych sieciach zasilajacych niskiego napiecia PN-EN 61000-3-3:2013:10 | PN-EN 61000-3-3:2013/A1:2019-10 | PN-EN 61000-3-3:2013/A2:2022-04","categories":["electronics"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems","search_en":"Electrical and electronic equipment Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems BEMC Laboratory PN-EN 61000-3-3:2013:10 | PN-EN 61000-3-3:2013/A1:2019-10 | PN-EN 61000-3-3:2013/A2:2022-04","test_object_en":"Electrical and electronic equipment","lab_section_zh":"BEMC 实验室","search_zh":"电气与电子设备 公用低压供电网中的电压变化、电压波动与闪烁 BEMC 实验室 PN-EN 61000-3-3:2013:10 | PN-EN 61000-3-3:2013/A1:2019-10 | PN-EN 61000-3-3:2013/A2:2022-04","test_object_zh":"电气与电子设备","methodology_zh":"公用低压供电网中的电压变化、电压波动与闪烁"},{"_id":"6a7d79e30636ba417e41af67","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na wyładowania","parameters":[{"name":"elektrostatyczne Zakres","range":"(2 – 15) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV","reference":"PN-EN 61000-4-2:2011","norm_bases":["PN-EN 61000-4-2:2011"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 61000-4-2:2011 Urzadzenia elektryczne i elektroniczne Odpornosc na wyladowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 61000-4-2:2011","categories":["electronics"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to discharges","parameters_en":[{"name":"electrostatic Range","range":"(2 – 15) kV"}],"search_en":"Electrical and electronic equipment Immunity to discharges BEMC Laboratory electrostatic Range PN-EN 61000-4-2:2011","test_object_en":"Electrical and electronic equipment","lab_section_zh":"BEMC 实验室","search_zh":"电气与电子设备 放电抗扰度 BEMC 实验室 静电 范围 PN-EN 61000-4-2:2011","test_object_zh":"电气与电子设备","methodology_zh":"放电抗扰度","parameters_zh":[{"name":"静电 范围","range":"(2 – 15) kV"}]},{"_id":"6a7d79e30636ba417e41af68","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na wyładowania","parameters":[{"name":"elektrostatyczne Zakres","range":"(2 – 15) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na wyladowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to discharges","parameters_en":[{"name":"electrostatic Range","range":"(2 – 15) kV"}],"search_en":"Medical electrical equipment Immunity to discharges BEMC Laboratory electrostatic Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","lab_section_zh":"BEMC 实验室","search_zh":"医用电气设备 放电抗扰度 BEMC 实验室 静电 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_zh":"医用电气设备","methodology_zh":"放电抗扰度","parameters_zh":[{"name":"静电 范围","range":"(2 – 15) kV"}]},{"_id":"6a7d79e30636ba417e41af69","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Odporność na wyładowania","parameters":[{"name":"elektrostatyczne Zakres","range":"(2 – 15) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV","reference":"PN-EN 61547:2009","norm_bases":["PN-EN 61547:2009"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Odporność na wyładowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 61547:2009 Sprzet oswietleniowy Odpornosc na wyladowania\nelektrostatyczne Zakres (2 – 15) kV PN-EN 61547:2009","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to discharges","parameters_en":[{"name":"electrostatic Range","range":"(2 – 15) kV"}],"search_en":"Lighting equipment Immunity to discharges BEMC Laboratory electrostatic Range PN-EN 61547:2009","test_object_en":"Lighting equipment","lab_section_zh":"BEMC 实验室","search_zh":"照明器材 放电抗扰度 BEMC 实验室 静电 范围 PN-EN 61547:2009","test_object_zh":"照明器材","methodology_zh":"放电抗扰度","parameters_zh":[{"name":"静电 范围","range":"(2 – 15) kV"}]},{"_id":"6a7d79e30636ba417e41af6a","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","parameters":[{"name":"Zakres","range":"(80 - 6000) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz","reference":"PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 | PN-EN IEC 61000-4-3:2021-06 | PN-EN 55016-2-4:2005","norm_bases":["PN-EN 61000-4-3:2007","PN-EN 61000-4-3:2007/A1:2008","PN-EN 61000-4-3:2007/A2:2011","PN-EN IEC 61000-4-3:2021-06","PN-EN 55016-2-4:2005"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 | PN-EN IEC 61000-4-3:2021-06 | PN-EN 55016-2-4:2005 Urzadzenia elektryczne i elektroniczne Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nZakres (80 - 6000) MHz PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 | PN-EN IEC 61000-4-3:2021-06 | PN-EN 55016-2-4:2005","categories":["electronics"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters_en":[{"name":"Range","range":"(80 - 6000) MHz"}],"search_en":"Electrical and electronic equipment Immunity to radiated radio-frequency electromagnetic field BEMC Laboratory Range PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 | PN-EN IEC 61000-4-3:2021-06 | PN-EN 55016-2-4:2005","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"(80 - 6000) MHz"}],"search_zh":"电气与电子设备 射频辐射电磁场抗扰度 BEMC 实验室 范围 PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 | PN-EN IEC 61000-4-3:2021-06 | PN-EN 55016-2-4:2005","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"射频辐射电磁场抗扰度"},{"_id":"6a7d79e30636ba417e41af6b","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","parameters":[{"name":"Zakres","range":"(80 - 6000) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nZakres (80 - 6000) MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters_en":[{"name":"Range","range":"(80 - 6000) MHz"}],"search_en":"Medical electrical equipment Immunity to radiated radio-frequency electromagnetic field BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"(80 - 6000) MHz"}],"search_zh":"医用电气设备 射频辐射电磁场抗扰度 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","methodology_zh":"射频辐射电磁场抗扰度","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af6c","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","parameters":[{"name":"Zakres","range":"(80 - 6000) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz","reference":"PN-EN 61547:2009","norm_bases":["PN-EN 61547:2009"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres (80 - 6000) MHz PN-EN 61547:2009 Sprzet oswietleniowy Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nZakres (80 - 6000) MHz PN-EN 61547:2009","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters_en":[{"name":"Range","range":"(80 - 6000) MHz"}],"search_en":"Lighting equipment Immunity to radiated radio-frequency electromagnetic field BEMC Laboratory Range PN-EN 61547:2009","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"(80 - 6000) MHz"}],"search_zh":"照明器材 射频辐射电磁场抗扰度 BEMC 实验室 范围 PN-EN 61547:2009","lab_section_zh":"BEMC 实验室","methodology_zh":"射频辐射电磁场抗扰度","test_object_zh":"照明器材"},{"_id":"6a7d79e30636ba417e41af6d","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","parameters":[{"name":"Zakres","range":"(0 - 30) A/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres (0 - 30) A/m","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres (0 - 30) A/m PN-EN 61000-4-8:2010 Urzadzenia elektryczne i elektroniczne Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nZakres (0 - 30) A/m PN-EN 61000-4-8:2010","categories":["electronics"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to power-frequency magnetic field","parameters_en":[{"name":"Range","range":"(0 - 30) A/m"}],"search_en":"Electrical and electronic equipment Immunity to power-frequency magnetic field BEMC Laboratory Range PN-EN 61000-4-8:2010","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"(0 - 30) A/m"}],"search_zh":"电气与电子设备 工频磁场抗扰度 BEMC 实验室 范围 PN-EN 61000-4-8:2010","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"工频磁场抗扰度"},{"_id":"6a7d79e30636ba417e41af6e","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","parameters":[{"name":"Zakres","range":"(0,5 – 4 ) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na serie szybkich elektrycznych stanow przejsciowych\nZakres (0,5 – 4 ) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to electrical fast transients/bursts","parameters_en":[{"name":"Range","range":"(0,5 – 4 ) kV"}],"search_en":"Medical electrical equipment Immunity to electrical fast transients/bursts BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4 ) kV"}],"search_zh":"医用电气设备 电快速瞬变脉冲群抗扰度 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","methodology_zh":"电快速瞬变脉冲群抗扰度","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af6f","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","parameters":[{"name":"Zakres","range":"(0,5 – 4 ) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV","reference":"PN-EN 61000-4-4:2013:05","norm_bases":["PN-EN 61000-4-4:2013:05"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV PN-EN 61000-4-4:2013:05 Urzadzenia elektryczne i elektroniczne Odpornosc na serie szybkich elektrycznych stanow przejsciowych\nZakres (0,5 – 4 ) kV PN-EN 61000-4-4:2013:05","categories":["electronics"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to electrical fast transients/bursts","parameters_en":[{"name":"Range","range":"(0,5 – 4 ) kV"}],"search_en":"Electrical and electronic equipment Immunity to electrical fast transients/bursts BEMC Laboratory Range PN-EN 61000-4-4:2013:05","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4 ) kV"}],"search_zh":"电气与电子设备 电快速瞬变脉冲群抗扰度 BEMC 实验室 范围 PN-EN 61000-4-4:2013:05","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"电快速瞬变脉冲群抗扰度"},{"_id":"6a7d79e30636ba417e41af70","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","parameters":[{"name":"Zakres","range":"(0,5 – 4 ) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV","reference":"PN-EN 61547:2009","norm_bases":["PN-EN 61547:2009"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres (0,5 – 4 ) kV PN-EN 61547:2009 Sprzet oswietleniowy Odpornosc na serie szybkich elektrycznych stanow przejsciowych\nZakres (0,5 – 4 ) kV PN-EN 61547:2009","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to electrical fast transients/bursts","parameters_en":[{"name":"Range","range":"(0,5 – 4 ) kV"}],"search_en":"Lighting equipment Immunity to electrical fast transients/bursts BEMC Laboratory Range PN-EN 61547:2009","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4 ) kV"}],"search_zh":"照明器材 电快速瞬变脉冲群抗扰度 BEMC 实验室 范围 PN-EN 61547:2009","lab_section_zh":"BEMC 实验室","methodology_zh":"电快速瞬变脉冲群抗扰度","test_object_zh":"照明器材"},{"_id":"6a7d79e30636ba417e41af71","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na udary","parameters":[{"name":"Zakres","range":"(0,5 – 4) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na udary\nZakres (0,5 – 4) kV","reference":"PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014/A1:2018-01","norm_bases":["PN-EN 61000-4-5:2014-10","PN-EN 61000-4-5:2014/A1:2018-01"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na udary\nZakres (0,5 – 4) kV PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014/A1:2018-01 Urzadzenia elektryczne i elektroniczne Odpornosc na udary\nZakres (0,5 – 4) kV PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014/A1:2018-01","categories":["electronics"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to surges","parameters_en":[{"name":"Range","range":"(0,5 – 4) kV"}],"search_en":"Electrical and electronic equipment Immunity to surges BEMC Laboratory Range PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014/A1:2018-01","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4) kV"}],"search_zh":"电气与电子设备 浪涌抗扰度 BEMC 实验室 范围 PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014/A1:2018-01","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"浪涌抗扰度"},{"_id":"6a7d79e30636ba417e41af72","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na udary","parameters":[{"name":"Zakres","range":"(0,5 – 4) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na udary\nZakres (0,5 – 4) kV","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na udary\nZakres (0,5 – 4) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na udary\nZakres (0,5 – 4) kV PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to surges","parameters_en":[{"name":"Range","range":"(0,5 – 4) kV"}],"search_en":"Medical electrical equipment Immunity to surges BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4) kV"}],"search_zh":"医用电气设备 浪涌抗扰度 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","methodology_zh":"浪涌抗扰度","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af73","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Odporność na udary","parameters":[{"name":"Zakres","range":"(0,5 – 4) kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na udary\nZakres (0,5 – 4) kV","reference":"PN-EN 61547:2009","norm_bases":["PN-EN 61547:2009"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Odporność na udary\nZakres (0,5 – 4) kV PN-EN 61547:2009 Sprzet oswietleniowy Odpornosc na udary\nZakres (0,5 – 4) kV PN-EN 61547:2009","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to surges","parameters_en":[{"name":"Range","range":"(0,5 – 4) kV"}],"search_en":"Lighting equipment Immunity to surges BEMC Laboratory Range PN-EN 61547:2009","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 4) kV"}],"search_zh":"照明器材 浪涌抗扰度 BEMC 实验室 范围 PN-EN 61547:2009","lab_section_zh":"BEMC 实验室","methodology_zh":"浪涌抗扰度","test_object_zh":"照明器材"},{"_id":"6a7d79e30636ba417e41af74","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","parameters":[{"name":"Zakres","range":"(0,15 - 230) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres (0,15 - 230) MHz","reference":"PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005","norm_bases":["PN-EN 61000-4-6:2014-04","PN-EN 61000-4-6:2024-03","PN-EN 55016-2-4:2005"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres (0,15 - 230) MHz PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005 Urzadzenia elektryczne i elektroniczne Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej\nZakres (0,15 - 230) MHz PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005","categories":["electronics"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters_en":[{"name":"Range","range":"(0,15 - 230) MHz"}],"search_en":"Electrical and electronic equipment Immunity to conducted disturbances induced by radio-frequency fields BEMC Laboratory Range PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"(0,15 - 230) MHz"}],"search_zh":"电气与电子设备 射频场感应的传导骚扰抗扰度 BEMC 实验室 范围 PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a7d79e30636ba417e41af75","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","parameters":[{"name":"Zakres","range":"(0,15 - 230) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres (0,15 - 230) MHz","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres (0,15 - 230) MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej\nZakres (0,15 - 230) MHz PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters_en":[{"name":"Range","range":"(0,15 - 230) MHz"}],"search_en":"Medical electrical equipment Immunity to conducted disturbances induced by radio-frequency fields BEMC Laboratory Range PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"(0,15 - 230) MHz"}],"search_zh":"医用电气设备 射频场感应的传导骚扰抗扰度 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","methodology_zh":"射频场感应的传导骚扰抗扰度","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af76","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","parameters":[{"name":"Zakres","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT","reference":"PN-EN 61000-4-11:2007 | PN-EN IEC 61000-4-11:2020-11 PN-EN | IEC 61000-4-11:2020 /AC:2020-12","norm_bases":["PN-EN 61000-4-11:2007","PN-EN IEC 61000-4-11:2020-11 PN-EN","IEC 61000-4-11:2020 /AC:2020-12"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 61000-4-11:2007 | PN-EN IEC 61000-4-11:2020-11 PN-EN | IEC 61000-4-11:2020 /AC:2020-12 Urzadzenia elektryczne i elektroniczne Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 61000-4-11:2007 | PN-EN IEC 61000-4-11:2020-11 PN-EN | IEC 61000-4-11:2020 /AC:2020-12","categories":["electronics"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters_en":[{"name":"Range","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_en":"Electrical and electronic equipment Immunity to voltage dips, short interruptions and voltage variations BEMC Laboratory Range 80 %UT PN-EN 61000-4-11:2007 | PN-EN IEC 61000-4-11:2020-11 PN-EN | IEC 61000-4-11:2020 /AC:2020-12","test_object_en":"Electrical and electronic equipment","parameters_zh":[{"name":"范围","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_zh":"电气与电子设备 电压暂降、短时中断与电压变化抗扰度 BEMC 实验室 范围 PN-EN 61000-4-11:2007 | PN-EN IEC 61000-4-11:2020-11 PN-EN | IEC 61000-4-11:2020 /AC:2020-12","lab_section_zh":"BEMC 实验室","test_object_zh":"电气与电子设备","methodology_zh":"电压暂降、短时中断与电压变化抗扰度"},{"_id":"6a7d79e30636ba417e41af77","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","parameters":[{"name":"Zakres","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT","reference":"PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","norm_bases":["PN-EN 60601-1-2:2015-11","PN-EN 60601-1-2:2015/A1:2021-07"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07 Elektryczne urzadzenia medyczne Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters_en":[{"name":"Range","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_en":"Medical electrical equipment Immunity to voltage dips, short interruptions and voltage variations BEMC Laboratory Range 80 %UT PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","test_object_en":"Medical electrical equipment","parameters_zh":[{"name":"范围","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_zh":"医用电气设备 电压暂降、短时中断与电压变化抗扰度 BEMC 实验室 范围 PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015/A1:2021-07","lab_section_zh":"BEMC 实验室","methodology_zh":"电压暂降、短时中断与电压变化抗扰度","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af78","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Sprzęt oświetleniowy","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","parameters":[{"name":"Zakres","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT","reference":"PN-EN 61547:2009","norm_bases":["PN-EN 61547:2009"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt oświetleniowy Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 61547:2009 Sprzet oswietleniowy Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia\nZakres:\nZakres 0 %UT, 40 %UT, 70 %UT,\n80 %UT PN-EN 61547:2009","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters_en":[{"name":"Range","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_en":"Lighting equipment Immunity to voltage dips, short interruptions and voltage variations BEMC Laboratory Range 80 %UT PN-EN 61547:2009","test_object_en":"Lighting equipment","parameters_zh":[{"name":"范围","range":"0 %UT, 40 %UT, 70 %UT,"},{"name":"80 %UT"}],"search_zh":"照明器材 电压暂降、短时中断与电压变化抗扰度 BEMC 实验室 范围 PN-EN 61547:2009","lab_section_zh":"BEMC 实验室","methodology_zh":"电压暂降、短时中断与电压变化抗扰度","test_object_zh":"照明器材"},{"_id":"6a7d79e30636ba417e41af79","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne, Sprzęt oświetleniowy","methodology":"Harmoniczne prądu wprowadzane do sieci zasilania","parameters":[{"name":"Zakres","range":"(2 - 40) harmonicznej"}],"technique":null,"techniques":[],"computed":[],"activity":"Harmoniczne prądu wprowadzane do sieci zasilania\nZakres (2 - 40) harmonicznej","reference":"PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019/A1:2021-08 | PN-EN 61000-3-2:2019/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011","norm_bases":["PN-EN 61000-3-2:2014-10","PN-EN 61000-3-2:2019-04","PN-EN 61000-3-2:2019/A1:2021-08","PN-EN 61000-3-2:2019/A2:2024-12","PN-EN 61000-4-7:2007","PN-EN 61000-4-7:2007/A1:2011"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne, Sprzęt oświetleniowy Harmoniczne prądu wprowadzane do sieci zasilania\nZakres (2 - 40) harmonicznej PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019/A1:2021-08 | PN-EN 61000-3-2:2019/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 Urzadzenia elektryczne i elektroniczne, Sprzet oswietleniowy Harmoniczne pradu wprowadzane do sieci zasilania\nZakres (2 - 40) harmonicznej PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019/A1:2021-08 | PN-EN 61000-3-2:2019/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011","categories":["electronics"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Current harmonics injected into the supply mains","parameters_en":[{"name":"Range","range":"(2 - 40) harmonicznej"}],"search_en":"Electrical and electronic equipment, Lighting equipment Current harmonics injected into the supply mains BEMC Laboratory Range PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019/A1:2021-08 | PN-EN 61000-3-2:2019/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011","test_object_en":"Electrical and electronic equipment, Lighting equipment","parameters_zh":[{"name":"范围","range":"(2 - 40) harmonicznej"}],"search_zh":"BEMC 实验室 范围 PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019/A1:2021-08 | PN-EN 61000-3-2:2019/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011","lab_section_zh":"BEMC 实验室"},{"_id":"6a7d79e30636ba417e41af7a","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne, Sprzęt oświetleniowy","methodology":"Emisja zaburzeń przewodzonych – moc zaburzeń","parameters":[{"name":"Zakres","range":"(30 - 300) MHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych – moc zaburzeń\nZakres (30 - 300) MHz","reference":"PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011","norm_bases":["PN-EN 55014-1:2017-06","PN-EN IEC 55014-1:2021-08","PN-EN 55016-2-2:2011"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne, Sprzęt oświetleniowy Emisja zaburzeń przewodzonych – moc zaburzeń\nZakres (30 - 300) MHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011 Urzadzenia elektryczne i elektroniczne, Sprzet oswietleniowy Emisja zaburzen przewodzonych – moc zaburzen\nZakres (30 - 300) MHz PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011","categories":["environment","electronics"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Emission of conducted disturbances – disturbance power","parameters_en":[{"name":"Range","range":"(30 - 300) MHz"}],"search_en":"Electrical and electronic equipment, Lighting equipment Emission of conducted disturbances – disturbance power BEMC Laboratory Range PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011","test_object_en":"Electrical and electronic equipment, Lighting equipment","parameters_zh":[{"name":"范围","range":"(30 - 300) MHz"}],"search_zh":"BEMC 实验室 范围 PN-EN 55014-1:2017-06 | PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011","lab_section_zh":"BEMC 实验室"},{"_id":"6a7d79e30636ba417e41af7b","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.7","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12 p. 8.7"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.7 Elektryczne urzadzenia medyczne Prad uplywu, Prad dotykowy, Prad uplywu uziomowy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.7","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Leakage current, Touch current, Earth leakage current","search_en":"Medical electrical equipment Leakage current, Touch current, Earth leakage current BEMC Laboratory PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.7","test_object_en":"Medical electrical equipment","lab_section_zh":"BEMC 实验室","search_zh":"医用电气设备 BEMC 实验室 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.7","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af7c","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczny sprzęt do użytku domowego i podobnego","methodology":"Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy","reference":"PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","norm_bases":["PN-EN 60335-1:2012 p. 13, p. 16","PN-EN 60335-1:2024-04 p. 13, p. 16"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczny sprzęt do użytku domowego i podobnego Prąd upływu, Prąd dotykowy, Prąd upływu uziomowy PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16 Elektryczny sprzet do uzytku domowego i podobnego Prad uplywu, Prad dotykowy, Prad uplywu uziomowy PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Leakage current, Touch current, Earth leakage current","search_en":"Electrical appliances for household and similar use Leakage current, Touch current, Earth leakage current BEMC Laboratory PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","test_object_en":"Electrical appliances for household and similar use","lab_section_zh":"BEMC 实验室","search_zh":"家用及类似用途电器 BEMC 实验室 PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","test_object_zh":"家用及类似用途电器"},{"_id":"6a7d79e30636ba417e41af7d","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Wytrzymałość elektryczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011A12:2014-12 p. 8.8","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011A12:2014-12 p. 8.8"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Wytrzymałość elektryczna PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011A12:2014-12 p. 8.8 Elektryczne urzadzenia medyczne Wytrzymalosc elektryczna PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011A12:2014-12 p. 8.8","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Electric strength","search_en":"Medical electrical equipment Electric strength BEMC Laboratory PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011A12:2014-12 p. 8.8","test_object_en":"Medical electrical equipment","lab_section_zh":"BEMC 实验室","search_zh":"医用电气设备 介电强度 BEMC 实验室 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011A12:2014-12 p. 8.8","test_object_zh":"医用电气设备","methodology_zh":"介电强度"},{"_id":"6a7d79e30636ba417e41af7e","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczny sprzęt do użytku domowego i podobnego","methodology":"Wytrzymałość elektryczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna","reference":"PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","norm_bases":["PN-EN 60335-1:2012 p. 13, p. 16","PN-EN 60335-1:2024-04 p. 13, p. 16"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczny sprzęt do użytku domowego i podobnego Wytrzymałość elektryczna PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16 Elektryczny sprzet do uzytku domowego i podobnego Wytrzymalosc elektryczna PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Electric strength","search_en":"Electrical appliances for household and similar use Electric strength BEMC Laboratory PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","test_object_en":"Electrical appliances for household and similar use","lab_section_zh":"BEMC 实验室","search_zh":"家用及类似用途电器 介电强度 BEMC 实验室 PN-EN 60335-1:2012 p. 13, p. 16 | PN-EN 60335-1:2024-04 p. 13, p. 16","test_object_zh":"家用及类似用途电器","methodology_zh":"介电强度"},{"_id":"6a7d79e30636ba417e41af7f","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Rezystancja uziemienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja uziemienia","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.6","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12 p. 8.6"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Rezystancja uziemienia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.6 Elektryczne urzadzenia medyczne Rezystancja uziemienia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.6","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Earthing resistance","search_en":"Medical electrical equipment Earthing resistance BEMC Laboratory PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.6","test_object_en":"Medical electrical equipment","lab_section_zh":"BEMC 实验室","search_zh":"医用电气设备 BEMC 实验室 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.6","test_object_zh":"医用电气设备"},{"_id":"6a7d79e30636ba417e41af80","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczny sprzęt do użytku domowego i podobnego","methodology":"Rezystancja uziemienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja uziemienia","reference":"PN-EN 60335-1:2012 p. 27 | PN-EN 60335-1:2024-04 p. 27","norm_bases":["PN-EN 60335-1:2012 p. 27","PN-EN 60335-1:2024-04 p. 27"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczny sprzęt do użytku domowego i podobnego Rezystancja uziemienia PN-EN 60335-1:2012 p. 27 | PN-EN 60335-1:2024-04 p. 27 Elektryczny sprzet do uzytku domowego i podobnego Rezystancja uziemienia PN-EN 60335-1:2012 p. 27 | PN-EN 60335-1:2024-04 p. 27","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Earthing resistance","search_en":"Electrical appliances for household and similar use Earthing resistance BEMC Laboratory PN-EN 60335-1:2012 p. 27 | PN-EN 60335-1:2024-04 p. 27","test_object_en":"Electrical appliances for household and similar use","lab_section_zh":"BEMC 实验室","search_zh":"家用及类似用途电器 BEMC 实验室 PN-EN 60335-1:2012 p. 27 | PN-EN 60335-1:2024-04 p. 27","test_object_zh":"家用及类似用途电器"},{"_id":"6a7d79e30636ba417e41af81","lab_id":"69ad52a3de79e566650fb81e","country":"PL","accr_number":"AB 1555","accr_body":"PCA","test_object":"Elektryczne urządzenia medyczne","methodology":"Rezystancja izolacji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja izolacji","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.8","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12 p. 8.8"],"lab_section":"Laboratorium BEMC","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia medyczne Rezystancja izolacji PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.8 Elektryczne urzadzenia medyczne Rezystancja izolacji PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.8","categories":["construction"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BEMC Laboratory","methodology_en":"Insulation resistance","search_en":"Medical electrical equipment Insulation resistance BEMC Laboratory PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.8","test_object_en":"Medical electrical equipment","lab_section_zh":"BEMC 实验室","search_zh":"医用电气设备 绝缘电阻 BEMC 实验室 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 p. 8.8","test_object_zh":"医用电气设备","methodology_zh":"绝缘电阻"}],"has_pdf":true}