{"lab":{"_id":"69ad52a3de79e566650fb81c","accr_number":"AB 1552","country":"PL","accr_body":"PCA","address":"ul. Chwaszczyńska 180, 81-571 Gdynia, LABORATORIUM BADAWCZE, ul. Wyzwolenia 14, 41-103 Siemianowice Śląskie","categories":["construction","materials","environment"],"city":"Siemianowice Śląskie","imported_at":"2026-03-08T10:42:43.265Z","methods_count":197,"name":"J.S. HAMILTON POLAND Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1552.pdf"],"scope_summary":"","search_text":"j.s. hamilton poland sp. z o.o. ul. chwaszczyńska 180, 81-571 gdynia, laboratorium badawcze, ul. wyzwolenia 14, 41-103 siemianowice śląskie pharma electronics other metrology materials construction water automotive environment","status":"active","updated_at":"2026-03-08T14:50:42.002Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:51:59.772Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201552,podmiot.html","parse_date":"2026-08-17T10:51:59.772Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/5; A/13","pl":"Badania akustyczne i drgań - obiekty budowlane, maszyny","en":"Acoustic and vibration tests of building items, machinery"},{"codes":"C/6; C/8; C/18; C/21","pl":"Badania chemiczne sprzętu elektrycznego i elektronicznego oraz materiałów stosowanych do produkcji sprzętu elektrycznego i elektronicznego","en":"Chemical tests of electrical and electronic equipment, materials used in production of electrical and electronic equipment"},{"codes":"E/6; E/13; E/14; E/21; E/37; E/53","pl":"Badania elektryczne i elektroniczne dla maszyn, zakładów produkcyjnych, wyrobów i wyposażenia elektrycznego, telekomunikacyjnego, wyposażenia medycznego oraz wyrobów z tworzyw sztucznych i gumy","en":"Electrical and electronic tests of machines, production plants, electrical and telecommunication products and equipment, medical equipment, rubber and plastic products"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska – hałas, drgania, oświetlenie w środowisku pracy, hałas w środowisku ogólnym","en":"Environmental engineering tests: noise, vibration and lighting in the work environment; noise in general environment"},{"codes":"G5; G/6; G/8; G/13; G/18; G/21; G23; G25; G/35; G/37; G/49; G/53; G/54","pl":"Badania dotyczące inżynierii środowiska dla maszyn, zakładów produkcyjnych, wyposażenia i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyrobów i materiałów konstrukcyjnych – w tym metali i kompozytów, papieru, tektury, materiałów opakowaniowych, wyrobów z tworzyw sztucznych i gumy, tekstyliów i skór, tkanin, przędzy, odzieży, wyrobów finalnych oraz zabawek","en":"Environmental engineering tests for machines, productions plants, construction equipment and objetct, electrical, telecommunication and electronic products and equipment, structural products and materials including metals and composites, paper, cardboard, packaging materials, plastic and rubber products, textiles and leather, fabrics, yarn, clothing, final products, toys"}],"issue":{"no":"19","date":"28.07.2026"},"map_coord":[50.305203,19.027564],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Wyzwolenia 14","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/c6e0410f3e131fd997a4165903463fbd/AB%201552.pdf","has_en":true,"category_counts":{"other":131,"construction":30,"materials":29,"environment":18,"automotive":3,"water":2,"electronics":1},"category_scores":{"other":80.19,"construction":4.21,"materials":3.93,"environment":1.51,"automotive":0.04,"water":0.02,"electronics":0},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Wyzwolenia 14","city":null,"postal":null}]},"methods":[{"_id":"6a82e7cf884ede9a1b2c41bd","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Wielkości geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["P N -EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Wielkosci geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Direct method Testing Laboratory Range P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","technique_en":"Direct method","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"直接法 检测实验室 范围 P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","technique_zh":"直接法"},{"_id":"6a82e7cf884ede9a1b2c41be","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Wytrzymałość na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Wytrzymałość na uderzenie PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Wytrzymalosc na uderzenie PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact strength","search_en":"Impact strength Testing Laboratory PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","lab_section_zh":"检测实验室","search_zh":"抗冲击强度 检测实验室 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","methodology_zh":"抗冲击强度"},{"_id":"6a82e7cf884ede9a1b2c41bf","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Wytrzymałość na spadek swobodny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na spadek swobodny","reference":"P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["P N -EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Wytrzymałość na spadek swobodny P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Wytrzymalosc na spadek swobodny P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Free-fall drop resistance","search_en":"Free-fall drop resistance Testing Laboratory P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","lab_section_zh":"检测实验室","search_zh":"自由跌落强度 检测实验室 P N -EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","methodology_zh":"自由跌落强度"},{"_id":"6a82e7cf884ede9a1b2c41c0","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Pomiar temperatury","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar temperatury\nZakres 0°C – 450°C","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","PN-EN IEC 60079-0:2018-09/AC:2020-04","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Pomiar temperatury\nZakres 0°C – 450°C PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Pomiar temperatury\nZakres 0°C – 450°C PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Temperature measurement","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Temperature measurement Testing Laboratory Range PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"检测实验室 范围 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017"},{"_id":"6a82e7cf884ede9a1b2c41c1","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Odporność termiczna na gorąco","parameters":[{"name":"Zakres","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60068-2-78:2013-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Odporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Odpornosc termiczna na goraco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Testing Laboratory Range PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"检测实验室 范围 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11"},{"_id":"6a82e7cf884ede9a1b2c41c2","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Odporność termiczna na zimno","parameters":[{"name":"Zakres","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60068-2-1:2009"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Odpornosc termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Testing Laboratory Range PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"检测实验室 范围 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009"},{"_id":"6a82e7cf884ede9a1b2c41c3","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Odporność na nagłą zmianę temperatury","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na nagłą zmianę temperatury","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Odporność na nagłą zmianę temperatury PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Odpornosc na nagla zmiane temperatury PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Resistance to sudden temperature change","search_en":"Resistance to sudden temperature change Testing Laboratory PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017"},{"_id":"6a82e7cf884ede9a1b2c41c4","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Pomiar rezystancji powierzchniowej niemetalowych części obudów, R = 1 x 104 - 1 x 1012 Ω","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar rezystancji powierzchniowej niemetalowych części obudów, R = 1 x 104 - 1 x 1012 Ω","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60079-32-2:2015-08"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Pomiar rezystancji powierzchniowej niemetalowych części obudów, R = 1 x 104 - 1 x 1012 Ω PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Pomiar rezystancji powierzchniowej niemetalowych czesci obudow, R = 1 x 104 - 1 x 1012 Ω PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08"},{"_id":"6a82e7cf884ede9a1b2c41c5","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Stopień ochrony IP","parameters":[{"name":"Zakres","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Stopien ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"IP degree of protection","parameters_en":[{"name":"Range","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_en":"IP degree of protection Testing Laboratory Range PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_zh":"检测实验室 范围 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017"},{"_id":"6a82e7cf884ede9a1b2c41c6","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji","methodology":"Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie poprzez przyłożenie:","parameters":[{"name":"siły (próba wyciągania) w zakresie od 1N","range":"do 10kN"},{"name":"momentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2Nm","range":"do 400 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie poprzez przyłożenie:\nZakres:\nsiły (próba wyciągania) w zakresie od 1N do 10kN\nmomentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2Nm do 400 Nm","reference":"PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003","norm_bases":["PN-EN 60079-0:2013-03","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012","IEC 60079-0:2012","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-G-50003:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne do pracy w przestrzeniach zagrożonych wybuchem, Przykłady: - elektryczne maszyny wirujące, - transformatory elektryczne, - łączniki i aparatura rozdzielcza, - oprawy oświetleniowe stałe i przenośne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urządzenia łączności i sygnalizacji, - zasilacze sieciowe prądu stałego, - urządzenia automatyki, sterowania i transmisji Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie poprzez przyłożenie:\nZakres:\nsiły (próba wyciągania) w zakresie od 1N do 10kN\nmomentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2Nm do 400 Nm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003 Urzadzenia elektryczne do pracy w przestrzeniach zagrozonych wybuchem, Przyklady: - elektryczne maszyny wirujace, - transformatory elektryczne, - laczniki i aparatura rozdzielcza, - oprawy oswietleniowe stale i przenosne, - lampy bateryjne i akumulatorowe, - bezpieczniki, - czujniki, przetworniki pomiarowe i aparatura kontrolno-pomiarowa, - urzadzenia lacznosci i sygnalizacji, - zasilacze sieciowe pradu stalego, - urzadzenia automatyki, sterowania i transmisji Zadlawienie i mocowanie wpustow kablowych – badanie bezposrednie poprzez przylozenie:\nZakres:\nsily (proba wyciagania) w zakresie od 1N do 10kN\nmomentu obrotowego (proba wytrzymalosci mechanicznej) w zakresie od 2Nm do 400 Nm PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003"},{"_id":"6a82e7cf884ede9a1b2c41c7","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Wielkości geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13","norm_bases":["P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13","EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13","IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Wielkosci geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Direct method Testing Laboratory Range P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13","technique_en":"Direct method","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 直接法 检测实验室 范围 P N-EN 60079-1:2014-12 pkt. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 pkt. 5,6,7,8,9,10,11,12,13","technique_zh":"直接法","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41c8","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Ciśnienie wybuchu, ciśnienie odniesienia (bazowe)","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda: pomiar max. ciśnienia wybuchu","techniques":["Metoda: pomiar max. ciśnienia wybuchu"],"computed":[],"activity":"Ciśnienie wybuchu, ciśnienie odniesienia (bazowe)\nZakres do 3 MPa\nMetoda: pomiar max. ciśnienia wybuchu","reference":"PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","norm_bases":["PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Ciśnienie wybuchu, ciśnienie odniesienia (bazowe)\nZakres do 3 MPa\nMetoda: pomiar max. ciśnienia wybuchu PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Cisnienie wybuchu, cisnienie odniesienia (bazowe)\nZakres do 3 MPa\nMetoda: pomiar max. cisnienia wybuchu PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Testing Laboratory Range PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 检测实验室 范围 PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41c9","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Wytrzymałość osłony na działanie ciśnienia","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda: obciążenie ciśnieniem statycznym","techniques":["Metoda: obciążenie ciśnieniem statycznym"],"computed":[],"activity":"Wytrzymałość osłony na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem statycznym","reference":"PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","norm_bases":["PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Wytrzymałość osłony na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem statycznym PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Wytrzymalosc oslony na dzialanie cisnienia\nZakres do 3 MPa\nMetoda: obciazenie cisnieniem statycznym PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Testing Laboratory Range PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 检测实验室 范围 PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41ca","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Wytrzymałość osłony na działanie ciśnienia","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda: obciążenie ciśnieniem dynamicznym","techniques":["Metoda: obciążenie ciśnieniem dynamicznym"],"computed":[],"activity":"Wytrzymałość osłony na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem dynamicznym","reference":"PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","norm_bases":["PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Wytrzymałość osłony na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem dynamicznym PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Wytrzymalosc oslony na dzialanie cisnienia\nZakres do 3 MPa\nMetoda: obciazenie cisnieniem dynamicznym PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Testing Laboratory Range PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 检测实验室 范围 PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41cb","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Zabezpieczenie przed przeniesieniem się wybuchu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zabezpieczenie przed przeniesieniem się wybuchu","reference":"PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","norm_bases":["PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Zabezpieczenie przed przeniesieniem się wybuchu PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Zabezpieczenie przed przeniesieniem sie wybuchu PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Protection against explosion transmission","search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Protection against explosion transmission Testing Laboratory PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 检测实验室 PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41cc","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d”","methodology":"Szczelność i wytrzymałość ognioszczelnych wpustów kablowych – badanie bezpośrednie poprzez:","parameters":[{"name":"działanie ciśnieniem (próba szczelności) w zakresie od 100 Pa","range":"do 3 MPa"},{"name":"przyłożenie momentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2 Nm","range":"do 400 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność i wytrzymałość ognioszczelnych wpustów kablowych – badanie bezpośrednie poprzez:\nZakres:\ndziałanie ciśnieniem (próba szczelności) w zakresie od 100 Pa do 3 MPa\nprzyłożenie momentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2 Nm do 400 Nm","reference":"PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","norm_bases":["PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony ognioszczelne „d” Szczelność i wytrzymałość ognioszczelnych wpustów kablowych – badanie bezpośrednie poprzez:\nZakres:\ndziałanie ciśnieniem (próba szczelności) w zakresie od 100 Pa do 3 MPa\nprzyłożenie momentu obrotowego (próba wytrzymałości mechanicznej) w zakresie od 2 Nm do 400 Nm PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony ognioszczelne „d” Szczelnosc i wytrzymalosc ognioszczelnych wpustow kablowych – badanie bezposrednie poprzez:\nZakres:\ndzialanie cisnieniem (proba szczelnosci) w zakresie od 100 Pa do 3 MPa\nprzylozenie momentu obrotowego (proba wytrzymalosci mechanicznej) w zakresie od 2 Nm do 400 Nm PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Testing Laboratory PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」 检测实验室 PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014","test_object_zh":"爆炸性环境用电气设备 － 隔爆外壳「d」"},{"_id":"6a82e7cf884ede9a1b2c41cd","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony gazowe z nadciśnieniem „p”","methodology":"Wymiary geometryczne liniowe","parameters":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne liniowe\nMetoda bezpośrednia","reference":"PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","norm_bases":["PN-EN 60079-2:2015-02","PN-EN 60079-2:2015-02/AC1:2015-11","EN 60079-2:2014","IEC 60079-2:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony gazowe z nadciśnieniem „p” Wymiary geometryczne liniowe\nMetoda bezpośrednia PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony gazowe z nadcisnieniem „p” Wymiary geometryczne liniowe\nMetoda bezposrednia PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","search_en":"Electrical apparatus for explosive atmospheres - Pressurized enclosures „p” Linear geometric dimensions Direct method Testing Laboratory PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","technique_en":"Direct method","test_object_en":"Electrical apparatus for explosive atmospheres - Pressurized enclosures „p”","lab_section_zh":"检测实验室","search_zh":"几何线性尺寸 直接法 检测实验室 PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","technique_zh":"直接法","methodology_zh":"几何线性尺寸"},{"_id":"6a82e7cf884ede9a1b2c41ce","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony gazowe z nadciśnieniem „p”","methodology":"Wytrzymałość obudowy na działanie ciśnienia","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda obciążenie ciśnieniem statycznym","techniques":["Metoda obciążenie ciśnieniem statycznym"],"computed":[],"activity":"Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda obciążenie ciśnieniem statycznym","reference":"PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","norm_bases":["PN-EN 60079-2:2015-02","PN-EN 60079-2:2015-02/AC1:2015-11","EN 60079-2:2014","IEC 60079-2:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Osłony gazowe z nadciśnieniem „p” Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda obciążenie ciśnieniem statycznym PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Oslony gazowe z nadcisnieniem „p” Wytrzymalosc obudowy na dzialanie cisnienia\nZakres do 3 MPa\nMetoda obciazenie cisnieniem statycznym PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for explosive atmospheres - Pressurized enclosures „p” Testing Laboratory Range PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014","test_object_en":"Electrical apparatus for explosive atmospheres - Pressurized enclosures „p”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"检测实验室 范围 PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014"},{"_id":"6a82e7cf884ede9a1b2c41cf","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e”","methodology":"Wielkości geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","norm_bases":["PN-EN 60079-7:2010","PN-EN 60079-7:2016-02","PN-EN 60079-7:2016-02/A1:2018-03","EN 60079-7:2015","IEC 60079-7:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e” Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Budowa wzmocniona ”e” Wielkosci geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e” Direct method Testing Laboratory Range PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","technique_en":"Direct method","test_object_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"爆炸性环境用电气设备 － 增安型「e」 直接法 检测实验室 范围 PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","technique_zh":"直接法","test_object_zh":"爆炸性环境用电气设备 － 增安型「e」"},{"_id":"6a82e7cf884ede9a1b2c41d0","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e”","methodology":"Wytrzymałość elektryczna izolacji","parameters":[{"name":"napięcie przemienne 0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji\nnapięcie przemienne 0,5 kV - 40 kV","reference":"PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015","norm_bases":["PN-EN 60079-7:2010","PN-EN 60079-7:2016-02","PN-EN 60079-7:2016-02/A1:2018-03","PN-EN 60060-2:2011","EN 60079-7:2015","IEC 60079-7:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e” Wytrzymałość elektryczna izolacji\nnapięcie przemienne 0,5 kV - 40 kV PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Budowa wzmocniona ”e” Wytrzymalosc elektryczna izolacji\nnapiecie przemienne 0,5 kV - 40 kV PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dielectric strength of the insulation","search_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e” Dielectric strength of the insulation Testing Laboratory PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015","test_object_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 增安型「e」 绝缘介电强度 检测实验室 PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015","methodology_zh":"绝缘介电强度","test_object_zh":"爆炸性环境用电气设备 － 增安型「e」"},{"_id":"6a82e7cf884ede9a1b2c41d1","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e”","methodology":"Wytrzymałość na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie","reference":"PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","norm_bases":["PN-EN 60079-7:2010","PN-EN 60079-7:2016-02","PN-EN 60079-7:2016-02/A1:2018-03","EN 60079-7:2015","IEC 60079-7:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e” Wytrzymałość na uderzenie PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Budowa wzmocniona ”e” Wytrzymalosc na uderzenie PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact strength","search_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e” Impact strength Testing Laboratory PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","test_object_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 增安型「e」 抗冲击强度 检测实验室 PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","methodology_zh":"抗冲击强度","test_object_zh":"爆炸性环境用电气设备 － 增安型「e」"},{"_id":"6a82e7cf884ede9a1b2c41d2","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e”","methodology":"Wytrzymałość na spadek swobodny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na spadek swobodny","reference":"PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","norm_bases":["PN-EN 60079-7:2010","PN-EN 60079-7:2016-02","PN-EN 60079-7:2016-02/A1:2018-03","EN 60079-7:2015","IEC 60079-7:2015"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Budowa wzmocniona ”e” Wytrzymałość na spadek swobodny PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Budowa wzmocniona ”e” Wytrzymalosc na spadek swobodny PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Free-fall drop resistance","search_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e” Free-fall drop resistance Testing Laboratory PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","test_object_en":"Electrical apparatus for explosive atmospheres – Increased safety ”e”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 增安型「e」 自由跌落强度 检测实验室 PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015","methodology_zh":"自由跌落强度","test_object_zh":"爆炸性环境用电气设备 － 增安型「e」"},{"_id":"6a82e7cf884ede9a1b2c41d3","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Wielkości geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Wielkości geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Wielkosci geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Direct method Testing Laboratory Range PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","technique_en":"Direct method","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"爆炸性环境用电气设备。本质安全型「i」 直接法 检测实验室 范围 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","technique_zh":"直接法","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d4","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Wytrzymałość elektryczna izolacji","parameters":[{"name":"napięcie przemienne 0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji\nnapięcie przemienne 0,5 kV - 40 kV","reference":"PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","PN-EN 60060-2:2011","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Wytrzymałość elektryczna izolacji\nnapięcie przemienne 0,5 kV - 40 kV PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Wytrzymalosc elektryczna izolacji\nnapiecie przemienne 0,5 kV - 40 kV PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dielectric strength of the insulation","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Dielectric strength of the insulation Testing Laboratory PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 绝缘介电强度 检测实验室 PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","methodology_zh":"绝缘介电强度","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d5","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Odstępy izolacyjne, Pomiar bezpośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odstępy izolacyjne, Pomiar bezpośredni","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Odstępy izolacyjne, Pomiar bezpośredni PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Odstepy izolacyjne, Pomiar bezposredni PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d6","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Pojemnosc ogniw i baterii, Odpornosc na zwarcie ogniw i baterii PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d7","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Badanie transformatorów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie transformatorów","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Badanie transformatorów PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Badanie transformatorow PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Testing of transformers","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing of transformers Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d8","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Próba zapłonu inicjowanego iskrami","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba zapłonu inicjowanego iskrami","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Próba zapłonu inicjowanego iskrami PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Proba zaplonu inicjowanego iskrami PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Spark-initiated ignition test","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Spark-initiated ignition test Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41d9","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Pomiar temperatury","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar temperatury\nZakres 0°C – 450°C","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Pomiar temperatury\nZakres 0°C – 450°C PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Pomiar temperatury\nZakres 0°C – 450°C PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Temperature measurement","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Temperature measurement Testing Laboratory Range PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 范围 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41da","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Próba wyciągowa kabla lub przewodu","parameters":[{"name":"siły w zakresie 1N - 10kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Próba wyciągowa kabla lub przewodu\nsiły w zakresie 1N - 10kN","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Próba wyciągowa kabla lub przewodu\nsiły w zakresie 1N - 10kN PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Proba wyciagowa kabla lub przewodu\nsily w zakresie 1N - 10kN PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41db","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Próba zanurzenia w wodzie bezpieczników wymagających hermetyzacji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba zanurzenia w wodzie bezpieczników wymagających hermetyzacji","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Próba zanurzenia w wodzie bezpieczników wymagających hermetyzacji PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Proba zanurzenia w wodzie bezpiecznikow wymagajacych hermetyzacji PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water immersion test of fuses requiring sealing","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Water immersion test of fuses requiring sealing Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41dc","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Pomiar energii zmagazynowanej przez elementy piezoelektryczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar energii zmagazynowanej przez elementy piezoelektryczne","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Pomiar energii zmagazynowanej przez elementy piezoelektryczne PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Pomiar energii zmagazynowanej przez elementy piezoelektryczne PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Measurement of the energy stored by piezoelectric elements","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Measurement of the energy stored by piezoelectric elements Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41dd","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i”","methodology":"Badanie zalew i przegród poprzez oddziaływanie siłą od 1N do 500N","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zalew i przegród poprzez oddziaływanie siłą od 1N do 500N","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011","IEC 60079-11:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem. Wykonanie iskrobezpieczne ”i” Badanie zalew i przegród poprzez oddziaływanie siłą od 1N do 500N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem. Wykonanie iskrobezpieczne ”i” Badanie zalew i przegrod poprzez oddzialywanie sila od 1N do 500N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Testing of encapsulation compounds and barriers by applying a force from 1N to 500N","search_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing of encapsulation compounds and barriers by applying a force from 1N to 500N Testing Laboratory PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_en":"Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备。本质安全型「i」 检测实验室 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023","test_object_zh":"爆炸性环境用电气设备。本质安全型「i」"},{"_id":"6a82e7cf884ede9a1b2c41de","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n”","methodology":"Wymiary geometryczne liniowe","parameters":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne liniowe\nMetoda bezpośrednia","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010","PN-EN IEC 60079-15:2019-06","EN IEC 60079-15:2019","IEC 60079-15:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n” Wymiary geometryczne liniowe\nMetoda bezpośrednia PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia budowy przeciwwybuchowej ”n” Wymiary geometryczne liniowe\nMetoda bezposrednia PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","search_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n” Linear geometric dimensions Direct method Testing Laboratory PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","technique_en":"Direct method","test_object_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备 几何线性尺寸 直接法 检测实验室 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","technique_zh":"直接法","methodology_zh":"几何线性尺寸","test_object_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备"},{"_id":"6a82e7cf884ede9a1b2c41df","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n”","methodology":"Odporność termiczna na gorąco","parameters":[{"name":"Zakres","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010","PN-EN IEC 60079-15:2019-06","EN IEC 60079-15:2019","IEC 60079-15:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n” Odporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia budowy przeciwwybuchowej ”n” Odpornosc termiczna na goraco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n” Testing Laboratory Range PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","test_object_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备 检测实验室 范围 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","test_object_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备"},{"_id":"6a82e7cf884ede9a1b2c41e0","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n”","methodology":"Wytrzymałość na spadek swobodny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na spadek swobodny","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n” Wytrzymałość na spadek swobodny PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia budowy przeciwwybuchowej ”n” Wytrzymalosc na spadek swobodny PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Free-fall drop resistance","search_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n” Free-fall drop resistance Testing Laboratory PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010","test_object_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备 自由跌落强度 检测实验室 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010","methodology_zh":"自由跌落强度","test_object_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备"},{"_id":"6a82e7cf884ede9a1b2c41e1","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n”","methodology":"Wytrzymałość elektryczna izolacji","parameters":[{"name":"Zakres","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010","PN-EN IEC 60079-15:2019-06","EN IEC 60079-15:2019","IEC 60079-15:2017"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia budowy przeciwwybuchowej ”n” Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia budowy przeciwwybuchowej ”n” Wytrzymalosc elektryczna izolacji\nZakres:\nZakres napiecie przemienne\n0,5 kV - 40 kV PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","categories":["construction"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dielectric strength of the insulation","parameters_en":[{"name":"Range","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n” Dielectric strength of the insulation Testing Laboratory Range PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","test_object_en":"Electrical apparatus for explosive atmospheres – Type of protection ”n”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备 绝缘介电强度 检测实验室 范围 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017","methodology_zh":"绝缘介电强度","test_object_zh":"爆炸性环境用电气设备 － 「n」型防爆结构设备"},{"_id":"6a82e7cf884ede9a1b2c41e2","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Badania termiczne, temperatury i przyrosty","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Testing Laboratory Range PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 范围 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e3","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Odporność termiczna na gorąco","parameters":[{"name":"Zakres","range":"do +180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na gorąco\nZakres:\nZakres do +180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Odporność termiczna na gorąco\nZakres:\nZakres do +180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Odpornosc termiczna na goraco\nZakres:\nZakres do +180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do +180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Testing Laboratory Range PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do +180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 范围 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e4","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Odporność termiczna na zimno","parameters":[{"name":"Zakres","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Odpornosc termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Testing Laboratory Range PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 范围 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e5","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Wytrzymałość elektryczna izolacji","parameters":[{"name":"Zakres","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Wytrzymalosc elektryczna izolacji\nZakres:\nZakres napiecie przemienne\n0,5 kV - 40 kV PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["construction"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dielectric strength of the insulation","parameters_en":[{"name":"Range","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Dielectric strength of the insulation Testing Laboratory Range PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 绝缘介电强度 检测实验室 范围 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","methodology_zh":"绝缘介电强度","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e6","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Wytrzymałość obudowy na działanie ciśnienia","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda obciążenie ciśnieniem statycznym","techniques":["Metoda obciążenie ciśnieniem statycznym"],"computed":[],"activity":"Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda obciążenie ciśnieniem statycznym","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda obciążenie ciśnieniem statycznym PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Wytrzymalosc obudowy na dzialanie cisnienia\nZakres do 3 MPa\nMetoda obciazenie cisnieniem statycznym PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Testing Laboratory Range PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 范围 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e7","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Absorpcja wody przez zalewę – zmiana masy w zakresie od 0,02g do 500g","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Absorpcja wody przez zalewę – zmiana masy w zakresie od 0,02g do 500g","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Absorpcja wody przez zalewę – zmiana masy w zakresie od 0,02g do 500g PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Absorpcja wody przez zalewe – zmiana masy w zakresie od 0,02g do 500g PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water absorption by the sealing compound – change of mass in the range from 0,02g to 500g","search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Water absorption by the sealing compound – change of mass in the range from 0,02g to 500g Testing Laboratory PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e8","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Próba wyciągania kabla lub przewodu – siły w zakresie 1N-10kN","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba wyciągania kabla lub przewodu – siły w zakresie 1N-10kN","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Próba wyciągania kabla lub przewodu – siły w zakresie 1N-10kN PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Proba wyciagania kabla lub przewodu – sily w zakresie 1N-10kN PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Testing Laboratory PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41e9","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m”","methodology":"Próba zanurzenia w wodzie wbudowanych zabezpieczeń wymagających hermetyzacji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba zanurzenia w wodzie wbudowanych zabezpieczeń wymagających hermetyzacji","reference":"PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","norm_bases":["PN-EN 60079-18:2015-06","PN-EN 60079-18:2015-06/A1:2018-02","EN 60079-18:2015","IEC 60079-18:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Urządzenia z ochroną hermetyzowaną ”m” Próba zanurzenia w wodzie wbudowanych zabezpieczeń wymagających hermetyzacji PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Urzadzenia z ochrona hermetyzowana ”m” Proba zanurzenia w wodzie wbudowanych zabezpieczen wymagajacych hermetyzacji PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water immersion test of built-in protective devices requiring sealing","search_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Water immersion test of built-in protective devices requiring sealing Testing Laboratory PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 浇封型「m」设备 检测实验室 PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014","test_object_zh":"爆炸性环境用电气设备 － 浇封型「m」设备"},{"_id":"6a82e7cf884ede9a1b2c41ea","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne","methodology":"Wymiary geometryczne liniowe","parameters":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne liniowe\nMetoda bezpośrednia","reference":"PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","norm_bases":["PN-EN 60079-25:2011","PN-EN IEC 60079-25:2023-02","EN 60079-25:2010","IEC 60079-25:2010","EN IEC 60079-25:2022","IEC 60079-25:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne Wymiary geometryczne liniowe\nMetoda bezpośrednia PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Systemy iskrobezpieczne Wymiary geometryczne liniowe\nMetoda bezposrednia PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","search_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Linear geometric dimensions Direct method Testing Laboratory PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","technique_en":"Direct method","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 本质安全系统 几何线性尺寸 直接法 检测实验室 PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","technique_zh":"直接法","methodology_zh":"几何线性尺寸","test_object_zh":"爆炸性环境用电气设备 － 本质安全系统"},{"_id":"6a82e7cf884ede9a1b2c41eb","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne","methodology":"Odstępy izolacyjne, Pomiar bezpośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odstępy izolacyjne, Pomiar bezpośredni","reference":"PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","norm_bases":["PN-EN 60079-25:2011","PN-EN IEC 60079-25:2023-02","EN 60079-25:2010","IEC 60079-25:2010","EN IEC 60079-25:2022","IEC 60079-25:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne Odstępy izolacyjne, Pomiar bezpośredni PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Systemy iskrobezpieczne Odstepy izolacyjne, Pomiar bezposredni PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","categories":["construction"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Testing Laboratory PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 本质安全系统 检测实验室 PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_zh":"爆炸性环境用电气设备 － 本质安全系统"},{"_id":"6a82e7cf884ede9a1b2c41ec","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne","methodology":"Wytrzymałość elektryczna izolacji","parameters":[{"name":"Zakres","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV","reference":"P N -EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","norm_bases":["P N -EN 60079-25:2011","PN-EN IEC 60079-25:2023-02","EN 60079-25:2010","IEC 60079-25:2010","EN IEC 60079-25:2022","IEC 60079-25:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne Wytrzymałość elektryczna izolacji\nZakres:\nZakres napięcie przemienne\n0,5 kV - 40 kV P N -EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Systemy iskrobezpieczne Wytrzymalosc elektryczna izolacji\nZakres:\nZakres napiecie przemienne\n0,5 kV - 40 kV P N -EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","categories":["construction"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dielectric strength of the insulation","parameters_en":[{"name":"Range","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Dielectric strength of the insulation Testing Laboratory Range P N -EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"napięcie przemienne"},{"name":"0,5 kV - 40 kV"}],"search_zh":"爆炸性环境用电气设备 － 本质安全系统 绝缘介电强度 检测实验室 范围 P N -EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","methodology_zh":"绝缘介电强度","test_object_zh":"爆炸性环境用电气设备 － 本质安全系统"},{"_id":"6a82e7cf884ede9a1b2c41ed","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne","methodology":"Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii","reference":"PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","norm_bases":["PN-EN 60079-25:2011","PN-EN IEC 60079-25:2023-02","EN 60079-25:2010","IEC 60079-25:2010","EN IEC 60079-25:2022","IEC 60079-25:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne Pojemność ogniw i baterii, Odporność na zwarcie ogniw i baterii PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Systemy iskrobezpieczne Pojemnosc ogniw i baterii, Odpornosc na zwarcie ogniw i baterii PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Testing Laboratory PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 本质安全系统 检测实验室 PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_zh":"爆炸性环境用电气设备 － 本质安全系统"},{"_id":"6a82e7cf884ede9a1b2c41ee","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne","methodology":"Badanie transformatorów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie transformatorów","reference":"PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","norm_bases":["PN-EN 60079-25:2011","PN-EN IEC 60079-25:2023-02","EN 60079-25:2010","IEC 60079-25:2010","EN IEC 60079-25:2022","IEC 60079-25:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeni zagrożonych wybuchem – Systemy iskrobezpieczne Badanie transformatorów PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020 Urzadzenia elektryczne w przestrzeni zagrozonych wybuchem – Systemy iskrobezpieczne Badanie transformatorow PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Testing of transformers","search_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Testing of transformers Testing Laboratory PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_en":"Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 本质安全系统 检测实验室 PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020","test_object_zh":"爆炸性环境用电气设备 － 本质安全系统"},{"_id":"6a82e7cf884ede9a1b2c41ef","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Urządzenia o poziomie zabezpieczenie urządzenia (EPL) Ga","methodology":"Wytrzymałość na uderzenie","parameters":[{"name":"Zakres","range":"Energia uderzenia do"},{"name":"20 J"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie\nZakres:\nZakres Energia uderzenia do\n20 J","reference":"PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","norm_bases":["PN-EN 60079-26:2015-04","EN 60079-26:2015","IEC 60079-26:2014","IEC 60079-26:2021","PN-EN 60079-26:2024-09","EN IEC 60079-26:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Urządzenia o poziomie zabezpieczenie urządzenia (EPL) Ga Wytrzymałość na uderzenie\nZakres:\nZakres Energia uderzenia do\n20 J PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Urzadzenia o poziomie zabezpieczenie urzadzenia (EPL) Ga Wytrzymalosc na uderzenie\nZakres:\nZakres Energia uderzenia do\n20 J PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact strength","parameters_en":[{"name":"Range","range":"Energia uderzenia do"},{"name":"20 J"}],"search_en":"Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga Impact strength Testing Laboratory Range PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"Energia uderzenia do"},{"name":"20 J"}],"search_zh":"抗冲击强度 检测实验室 范围 PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","methodology_zh":"抗冲击强度"},{"_id":"6a82e7cf884ede9a1b2c41f0","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Urządzenia o poziomie zabezpieczenie urządzenia (EPL) Ga","methodology":"Badania termiczne, temperatury i przyrosty","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C","reference":"PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","norm_bases":["PN-EN 60079-26:2015-04","EN 60079-26:2015","IEC 60079-26:2014","IEC 60079-26:2021","PN-EN 60079-26:2024-09","EN IEC 60079-26:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Urządzenia o poziomie zabezpieczenie urządzenia (EPL) Ga Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Urzadzenia o poziomie zabezpieczenie urzadzenia (EPL) Ga Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga Testing Laboratory Range PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"检测实验室 范围 PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024"},{"_id":"6a82e7cf884ede9a1b2c41f1","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem wykorzystujące promieniowanie optyczne, zabezpieczenie – zabezpieczenie „op-is”","methodology":"Pomiar mocy optycznej do 1 W","parameters":[{"name":"pasmo","range":"(190 - 20000) nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar mocy optycznej do 1 W\npasmo (190 - 20000) nm","reference":"PN-EN 60079-28:2015-12 | IEC 60079-28 Ed. 2.0 2015-05","norm_bases":["PN-EN 60079-28:2015-12","IEC 60079-28 Ed. 2.0 2015-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem wykorzystujące promieniowanie optyczne, zabezpieczenie – zabezpieczenie „op-is” Pomiar mocy optycznej do 1 W\npasmo (190 - 20000) nm PN-EN 60079-28:2015-12 | IEC 60079-28 Ed. 2.0 2015-05 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem wykorzystujace promieniowanie optyczne, zabezpieczenie – zabezpieczenie „op-is” Pomiar mocy optycznej do 1 W\npasmo (190 - 20000) nm PN-EN 60079-28:2015-12 | IEC 60079-28 Ed. 2.0 2015-05","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical equipment for explosive atmospheres using optical radiation, protection – protection “op-is” Testing Laboratory PN-EN 60079-28:2015-12 | IEC 60079-28 Ed. 2.0 2015-05","test_object_en":"Electrical equipment for explosive atmospheres using optical radiation, protection – protection “op-is”","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60079-28:2015-12 | IEC 60079-28 Ed. 2.0 2015-05"},{"_id":"6a82e7cf884ede9a1b2c41f2","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t”","methodology":"Stopień ochrony IP","parameters":[{"name":"Zakres","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8","reference":"PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","norm_bases":["PN-EN 60079-31:2014-10","EN 60079-31:2014","IEC 60079-31:2013","IEC 60079-31:2022","PN-EN 60079-31:2024-08","EN IEC 60079-31:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t” Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Zabezpieczenie urzadzen przed zaplonem pylu obudowa typu „t” Stopien ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"IP degree of protection","parameters_en":[{"name":"Range","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” IP degree of protection Testing Laboratory Range PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳 检测实验室 范围 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳"},{"_id":"6a82e7cf884ede9a1b2c41f3","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t”","methodology":"Wytrzymałość obudowy na działanie ciśnienia","parameters":[{"name":"Zakres","range":"do 3 MPa"}],"technique":"Metoda: obciążenie ciśnieniem statycznym","techniques":["Metoda: obciążenie ciśnieniem statycznym"],"computed":[],"activity":"Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem statycznym","reference":"PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","norm_bases":["PN-EN 60079-31:2014-10","EN 60079-31:2014","IEC 60079-31:2013","IEC 60079-31:2022","PN-EN 60079-31:2024-08","EN IEC 60079-31:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t” Wytrzymałość obudowy na działanie ciśnienia\nZakres do 3 MPa\nMetoda: obciążenie ciśnieniem statycznym PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Zabezpieczenie urzadzen przed zaplonem pylu obudowa typu „t” Wytrzymalosc obudowy na dzialanie cisnienia\nZakres do 3 MPa\nMetoda: obciazenie cisnieniem statycznym PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 3 MPa"}],"search_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Testing Laboratory Range PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 3 MPa"}],"search_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳 检测实验室 范围 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳"},{"_id":"6a82e7cf884ede9a1b2c41f4","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t”","methodology":"Badania termiczne, temperatury i przyrosty","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C","reference":"PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","norm_bases":["PN-EN 60079-31:2014-10","EN 60079-31:2014","IEC 60079-31:2013","IEC 60079-31:2022","PN-EN 60079-31:2024-08","EN IEC 60079-31:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t” Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Zabezpieczenie urzadzen przed zaplonem pylu obudowa typu „t” Badania termiczne, temperatury i przyrosty\nZakres 0°C – 450°C PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Testing Laboratory Range PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t”","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳 检测实验室 范围 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳"},{"_id":"6a82e7cf884ede9a1b2c41f5","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t”","methodology":"Wytrzymałość na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie","reference":"PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","norm_bases":["PN-EN 60079-31:2014-10","EN 60079-31:2014","IEC 60079-31:2013","IEC 60079-31:2022","PN-EN 60079-31:2024-08","EN IEC 60079-31:2024"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne w przestrzeniach zagrożonych wybuchem - Zabezpieczenie urządzeń przed zapłonem pyłu obudowa typu „t” Wytrzymałość na uderzenie PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024 Urzadzenia elektryczne w przestrzeniach zagrozonych wybuchem - Zabezpieczenie urzadzen przed zaplonem pylu obudowa typu „t” Wytrzymalosc na uderzenie PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact strength","search_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Impact strength Testing Laboratory PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","test_object_en":"Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t”","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳 抗冲击强度 检测实验室 PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024","methodology_zh":"抗冲击强度","test_object_zh":"爆炸性环境用电气设备 － 粉尘点燃防护「t」型外壳"},{"_id":"6a82e7cf884ede9a1b2c41f6","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP)","methodology":"Stopień ochrony IP","parameters":[{"name":"Zakres","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8","reference":"PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020","norm_bases":["PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","EN 60529:1991+A1:2000","EN 60529:1991/A2:2013","IEC 60529:2001","IEC 60529:1989/AMD2:2013","PN-EN IEC 60034-5:2021-01","EN IEC 60034-5:2020","IEC 60034-5:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020 Maszyny i urzadzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopien ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"IP degree of protection","parameters_en":[{"name":"Range","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code) IP degree of protection Testing Laboratory Range PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020","test_object_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code)","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_zh":"机器与设备。外壳提供的防护等级（IP 代码） 检测实验室 范围 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020","test_object_zh":"机器与设备。外壳提供的防护等级（IP 代码）"},{"_id":"6a82e7cf884ede9a1b2c41f7","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP)","methodology":"Stopień ochrony IP: 1X, 2X, 3X, 4X, 5kX, 6kX, X1, X2, X3, X4, X5, X6, X7, X8","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IP: 1X, 2X, 3X, 4X, 5kX, 6kX, X1, X2, X3, X4, X5, X6, X7, X8","reference":"ISO 20653:2023 (E)","norm_bases":["ISO 20653:2023 (E)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopień ochrony IP: 1X, 2X, 3X, 4X, 5kX, 6kX, X1, X2, X3, X4, X5, X6, X7, X8 ISO 20653:2023 (E) Maszyny i urzadzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopien ochrony IP: 1X, 2X, 3X, 4X, 5kX, 6kX, X1, X2, X3, X4, X5, X6, X7, X8 ISO 20653:2023 (E)","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code) Testing Laboratory ISO 20653:2023 (E)","test_object_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code)","lab_section_zh":"检测实验室","search_zh":"机器与设备。外壳提供的防护等级（IP 代码） 检测实验室 ISO 20653:2023 (E)","test_object_zh":"机器与设备。外壳提供的防护等级（IP 代码）"},{"_id":"6a82e7cf884ede9a1b2c41f8","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych","methodology":"Stopień ochrony IK","parameters":[{"name":"Zakres","range":"(IK01 - IK10), IK 50J"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IK\nZakres (IK01 - IK10), IK 50J","reference":"PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (próba Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06","norm_bases":["PN-EN 50102:2001","PN-EN 50102:2001/AC:2011","PN-EN 60068-2-75:2015-01 (próba Ehc)","PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych Stopień ochrony IK\nZakres (IK01 - IK10), IK 50J PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (próba Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 Obudowy urzadzen elektrycznych Stopien ochrony IK\nZakres (IK01 - IK10), IK 50J PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (proba Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"(IK01 - IK10), IK 50J"}],"search_en":"Enclosures for electrical equipment Testing Laboratory Range PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (próba Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06","test_object_en":"Enclosures for electrical equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(IK01 - IK10), IK 50J"}],"search_zh":"检测实验室 范围 PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (próba Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06"},{"_id":"6a82e7cf884ede9a1b2c41f9","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych","methodology":"Odporność na uderzenie - próba młotem sprężynowym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenie - próba młotem sprężynowym","reference":"PN-EN 60068-2-75:2015-01 (próba Ehb)","norm_bases":["PN-EN 60068-2-75:2015-01 (próba Ehb)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowy urządzeń elektrycznych Odporność na uderzenie - próba młotem sprężynowym PN-EN 60068-2-75:2015-01 (próba Ehb) Obudowy urzadzen elektrycznych Odpornosc na uderzenie - proba mlotem sprezynowym PN-EN 60068-2-75:2015-01 (proba Ehb)","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact resistance - spring hammer test","search_en":"Enclosures for electrical equipment Impact resistance - spring hammer test Testing Laboratory PN-EN 60068-2-75:2015-01 (próba Ehb)","test_object_en":"Enclosures for electrical equipment","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60068-2-75:2015-01 (próba Ehb)"},{"_id":"6a82e7cf884ede9a1b2c41fa","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Wymiary geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["P N -EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Linear geometric dimensions Direct method Testing Laboratory Range P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","technique_en":"Direct method","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"爆炸性环境用非电气设备 几何线性尺寸 直接法 检测实验室 范围 P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","technique_zh":"直接法","methodology_zh":"几何线性尺寸","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c41fb","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Wytrzymałość na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na uderzenie","reference":"P N - E N ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["P N - E N ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Wytrzymałość na uderzenie P N - E N ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Wytrzymalosc na uderzenie P N - E N ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact strength","search_en":"Non-electrical equipment for use in potentially explosive atmospheres Impact strength Testing Laboratory P N - E N ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用非电气设备 抗冲击强度 检测实验室 P N - E N ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备","methodology_zh":"抗冲击强度"},{"_id":"6a82e7cf884ede9a1b2c41fc","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Wytrzymałość na spadek swobodny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na spadek swobodny","reference":"P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["P N -EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Wytrzymałość na spadek swobodny P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Wytrzymalosc na spadek swobodny P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Free-fall drop resistance","search_en":"Non-electrical equipment for use in potentially explosive atmospheres Free-fall drop resistance Testing Laboratory P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用非电气设备 自由跌落强度 检测实验室 P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备","methodology_zh":"自由跌落强度"},{"_id":"6a82e7cf884ede9a1b2c41fd","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Pomiar temperatury","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar temperatury\nZakres 0°C – 450°C","reference":"PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Pomiar temperatury\nZakres 0°C – 450°C PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Pomiar temperatury\nZakres 0°C – 450°C PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Temperature measurement","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Temperature measurement Testing Laboratory Range PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"爆炸性环境用非电气设备 检测实验室 范围 PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c41fe","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Odporność na szok termiczny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na szok termiczny","reference":"PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Odporność na szok termiczny PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Odpornosc na szok termiczny PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Resistance to thermal shock","search_en":"Non-electrical equipment for use in potentially explosive atmospheres Resistance to thermal shock Testing Laboratory PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","search_zh":"爆炸性环境用非电气设备 耐热震性 检测实验室 PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备","methodology_zh":"耐热震性"},{"_id":"6a82e7cf884ede9a1b2c41ff","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Rezystancja powierzchniowa RS","parameters":[{"name":"Zakres","range":"R = 1 x 104 - 1 x 1012 Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja powierzchniowa RS\nZakres R = 1 x 104 - 1 x 1012 Ω","reference":"PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Rezystancja powierzchniowa RS\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Rezystancja powierzchniowa RS\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Testing Laboratory Range PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_zh":"爆炸性环境用非电气设备 检测实验室 范围 PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c4200","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Oporność termiczna na gorąco","parameters":[{"name":"Zakres","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Oporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 80079-36:2016-07","PN-EN ISO 80079-36:2016-07/AC:2020-05","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Oporność termiczna na gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Opornosc termiczna na goraco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Testing Laboratory Range PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"爆炸性环境用非电气设备 检测实验室 范围 PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c4201","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Odporność termiczna na zimno","parameters":[{"name":"Zakres","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Odporność termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Odpornosc termiczna na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Testing Laboratory Range PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"爆炸性环境用非电气设备 检测实验室 范围 PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c4202","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem","methodology":"Wymiary geometryczne liniowe","parameters":[{"name":"Zakres","range":"0,01 mm - 30 m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia","reference":"P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["P N -EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezpośrednia P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem Wymiary geometryczne liniowe\nZakres 0,01 mm - 30 m\nMetoda bezposrednia P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","parameters_en":[{"name":"Range","range":"0,01 mm - 30 m"}],"search_en":"Non-electrical equipment for use in potentially explosive atmospheres Linear geometric dimensions Direct method Testing Laboratory Range P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","technique_en":"Direct method","test_object_en":"Non-electrical equipment for use in potentially explosive atmospheres","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,01 mm - 30 m"}],"search_zh":"爆炸性环境用非电气设备 几何线性尺寸 直接法 检测实验室 范围 P N -EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","technique_zh":"直接法","methodology_zh":"几何线性尺寸","test_object_zh":"爆炸性环境用非电气设备"},{"_id":"6a82e7cf884ede9a1b2c4203","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego","methodology":"Rezystancja powierzchniowa RS materiałów niemetalowych","parameters":[{"name":"Zakres","range":"R = 1 x 104 - 1 x 1012 Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja powierzchniowa RS materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω","reference":"PN-EN 61340-2-3:2016-11","norm_bases":["PN-EN 61340-2-3:2016-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego Rezystancja powierzchniowa RS materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11 Plaskie materialy stale uzywane do zapobiegania gromadzeniu sie ladunku elektrostatycznego Rezystancja powierzchniowa RS materialow niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11","categories":["materials"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_en":"Flat solid materials used to prevent electrostatic charge accumulation Testing Laboratory Range PN-EN 61340-2-3:2016-11","test_object_en":"Flat solid materials used to prevent electrostatic charge accumulation","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_zh":"用于防止静电荷积聚的平面固体材料 检测实验室 范围 PN-EN 61340-2-3:2016-11","test_object_zh":"用于防止静电荷积聚的平面固体材料"},{"_id":"6a82e7cf884ede9a1b2c4204","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego","methodology":"Rezystancja skrośna RV materiałów niemetalowych","parameters":[{"name":"Zakres","range":"R = 1 x 104 - 1 x 1012 Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja skrośna RV materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω","reference":"PN-EN 61340-2-3:2016-11","norm_bases":["PN-EN 61340-2-3:2016-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego Rezystancja skrośna RV materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11 Plaskie materialy stale uzywane do zapobiegania gromadzeniu sie ladunku elektrostatycznego Rezystancja skrosna RV materialow niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11","categories":["materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_en":"Flat solid materials used to prevent electrostatic charge accumulation Testing Laboratory Range PN-EN 61340-2-3:2016-11","test_object_en":"Flat solid materials used to prevent electrostatic charge accumulation","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_zh":"用于防止静电荷积聚的平面固体材料 检测实验室 范围 PN-EN 61340-2-3:2016-11","test_object_zh":"用于防止静电荷积聚的平面固体材料"},{"_id":"6a82e7cf884ede9a1b2c4205","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego","methodology":"Rezystancja między punktami RP materiałów niemetalowych","parameters":[{"name":"Zakres","range":"R = 1 x 104 - 1 x 1012 Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja między punktami RP materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω","reference":"PN-EN 61340-2-3:2016-11","norm_bases":["PN-EN 61340-2-3:2016-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płaskie materiały stałe używane do zapobiegania gromadzeniu się ładunku elektrostatycznego Rezystancja między punktami RP materiałów niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11 Plaskie materialy stale uzywane do zapobiegania gromadzeniu sie ladunku elektrostatycznego Rezystancja miedzy punktami RP materialow niemetalowych\nZakres R = 1 x 104 - 1 x 1012 Ω PN-EN 61340-2-3:2016-11","categories":["materials"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_en":"Flat solid materials used to prevent electrostatic charge accumulation Testing Laboratory Range PN-EN 61340-2-3:2016-11","test_object_en":"Flat solid materials used to prevent electrostatic charge accumulation","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"R = 1 x 104 - 1 x 1012 Ω"}],"search_zh":"用于防止静电荷积聚的平面固体材料 检测实验室 范围 PN-EN 61340-2-3:2016-11","test_object_zh":"用于防止静电荷积聚的平面固体材料"},{"_id":"6a82e7cf884ede9a1b2c4206","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe","methodology":"Czas palenia","parameters":[{"name":"Czas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)"}],"technique":"Metoda płomieniowa","techniques":["Metoda płomieniowa"],"computed":[],"activity":"Czas palenia\nCzas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)\nMetoda płomieniowa","reference":"PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02 p. 6.2","norm_bases":["PN-EN ISO 340:2022-12","PN-EN ISO/IEC 80079-38:2017-02 p. 6.2"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe Czas palenia\nCzas przyłożenia płomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)\nMetoda płomieniowa PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02 p. 6.2 Materialy niemetalowe Czas palenia\nCzas przylozenia plomienia 10 s (zgodnie z PN-EN ISO/IEC 80079-38:2017-02 p. 6.2)\nMetoda plomieniowa PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02 p. 6.2","categories":["materials"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Burning time","search_en":"Non-metallic materials Burning time Flame method Testing Laboratory PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02 p. 6.2","technique_en":"Flame method","test_object_en":"Non-metallic materials","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02 p. 6.2"},{"_id":"6a82e7cf884ede9a1b2c4207","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały stosowane w pojazdach","methodology":"Czas palenia, Zasięg płomienia, Szybkość spalania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas palenia, Zasięg płomienia, Szybkość spalania","reference":"PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zał. 6 | DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6","norm_bases":["PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zał. 6","DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały stosowane w pojazdach Czas palenia, Zasięg płomienia, Szybkość spalania PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zał. 6 | DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6 Materialy stosowane w pojazdach Czas palenia, Zasieg plomienia, Szybkosc spalania PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zal. 6 | DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6","categories":["materials","automotive"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Materials used in vehicles Testing Laboratory PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zał. 6 | DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6","test_object_en":"Materials used in vehicles","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-ISO 3795:1996 FMVSS 302 Regulamin EKG ONZ nr 118 – Zał. 6 | DIN 75200:1980-09 TL 1010:2008-01 PSA D45 1333:2020-01 GB 8410:2006 PTL 8501 (Porsche) D45 1333 (Renault) STD 5031.19 (Volvo) JIS D 1201 (J) / p.6"},{"_id":"6a82e7cf884ede9a1b2c4208","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Taśmy przenośnikowe","methodology":"Czas palenia","parameters":[],"technique":"Metoda płomieniowa","techniques":["Metoda płomieniowa"],"computed":[],"activity":"Czas palenia\nMetoda płomieniowa","reference":"PN-EN ISO 340:2022-12 | PN-93-C-05013","norm_bases":["PN-EN ISO 340:2022-12","PN-93-C-05013"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Taśmy przenośnikowe Czas palenia\nMetoda płomieniowa PN-EN ISO 340:2022-12 | PN-93-C-05013 Tasmy przenosnikowe Czas palenia\nMetoda plomieniowa PN-EN ISO 340:2022-12 | PN-93-C-05013","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Burning time","search_en":"Conveyor belts Burning time Flame method Testing Laboratory PN-EN ISO 340:2022-12 | PN-93-C-05013","technique_en":"Flame method","test_object_en":"Conveyor belts","lab_section_zh":"检测实验室","search_zh":"输送带 检测实验室 PN-EN ISO 340:2022-12 | PN-93-C-05013","test_object_zh":"输送带"},{"_id":"6a82e7cf884ede9a1b2c4209","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Taśmy przenośnikowe","methodology":"Rezystancja powierzchniowa, Wartość rezystancji od 1 x 103 Ω do 1 x 1012 Ω","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja powierzchniowa, Wartość rezystancji od 1 x 103 Ω do 1 x 1012 Ω","reference":"PN-EN ISO 284:2013-06","norm_bases":["PN-EN ISO 284:2013-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Taśmy przenośnikowe Rezystancja powierzchniowa, Wartość rezystancji od 1 x 103 Ω do 1 x 1012 Ω PN-EN ISO 284:2013-06 Tasmy przenosnikowe Rezystancja powierzchniowa, Wartosc rezystancji od 1 x 103 Ω do 1 x 1012 Ω PN-EN ISO 284:2013-06","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Conveyor belts Testing Laboratory PN-EN ISO 284:2013-06","test_object_en":"Conveyor belts","lab_section_zh":"检测实验室","search_zh":"输送带 检测实验室 PN-EN ISO 284:2013-06","test_object_zh":"输送带"},{"_id":"6a82e7cf884ede9a1b2c420a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Taśmy przenośnikowe","methodology":"Wytrzymałość na rozciąganie wydłużenie przy zerwaniu wydłużenie przy zadanym obciążeniu siła (1-1000) kN przemieszczenie (0-98) mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie wydłużenie przy zerwaniu wydłużenie przy zadanym obciążeniu siła (1-1000) kN przemieszczenie (0-98) mm","reference":"PN-EN ISO 283:2023-10","norm_bases":["PN-EN ISO 283:2023-10"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Taśmy przenośnikowe Wytrzymałość na rozciąganie wydłużenie przy zerwaniu wydłużenie przy zadanym obciążeniu siła (1-1000) kN przemieszczenie (0-98) mm PN-EN ISO 283:2023-10 Tasmy przenosnikowe Wytrzymalosc na rozciaganie wydluzenie przy zerwaniu wydluzenie przy zadanym obciazeniu sila (1-1000) kN przemieszczenie (0-98) mm PN-EN ISO 283:2023-10","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Tensile strength elongation at break elongation at a specified load force (1-1000) kN displacement (0-98) mm","search_en":"Conveyor belts Tensile strength elongation at break elongation at a specified load force (1-1000) kN displacement (0-98) mm Testing Laboratory PN-EN ISO 283:2023-10","test_object_en":"Conveyor belts","lab_section_zh":"检测实验室","search_zh":"输送带 检测实验室 PN-EN ISO 283:2023-10","test_object_zh":"输送带"},{"_id":"6a82e7cf884ede9a1b2c420b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Taśmy przenośnikowe","methodology":"Wytrzymałość złącza siła (1-1000) kN","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość złącza siła (1-1000) kN","reference":"PN-EN ISO 1120:2013-03","norm_bases":["PN-EN ISO 1120:2013-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Taśmy przenośnikowe Wytrzymałość złącza siła (1-1000) kN PN-EN ISO 1120:2013-03 Tasmy przenosnikowe Wytrzymalosc zlacza sila (1-1000) kN PN-EN ISO 1120:2013-03","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Strength of the joint force (1-1000) kN","search_en":"Conveyor belts Strength of the joint force (1-1000) kN Testing Laboratory PN-EN ISO 1120:2013-03","test_object_en":"Conveyor belts","lab_section_zh":"检测实验室","search_zh":"输送带 检测实验室 PN-EN ISO 1120:2013-03","test_object_zh":"输送带"},{"_id":"6a82e7cf884ede9a1b2c420c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Taśmy przenośnikowe","methodology":"Tarcie na bębnie, Maksymalna temperatura bębna, Obecność płomienia i/lub żaru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tarcie na bębnie, Maksymalna temperatura bębna, Obecność płomienia i/lub żaru","reference":"PN-EN ISO 20238:2019-05 z wyłączeniem metody: A.1.2, A.2.2, B.1.2, B.2.2","norm_bases":["PN-EN ISO 20238:2019-05 z wyłączeniem metody: A.1.2, A.2.2, B.1.2, B.2.2"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Taśmy przenośnikowe Tarcie na bębnie, Maksymalna temperatura bębna, Obecność płomienia i/lub żaru PN-EN ISO 20238:2019-05 z wyłączeniem metody: A.1.2, A.2.2, B.1.2, B.2.2 Tasmy przenosnikowe Tarcie na bebnie, Maksymalna temperatura bebna, Obecnosc plomienia i/lub zaru PN-EN ISO 20238:2019-05 z wylaczeniem metody: A.1.2, A.2.2, B.1.2, B.2.2","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Conveyor belts Testing Laboratory PN-EN ISO 20238:2019-05 z wyłączeniem metody: A.1.2, A.2.2, B.1.2, B.2.2","test_object_en":"Conveyor belts","lab_section_zh":"检测实验室","search_zh":"输送带 检测实验室 PN-EN ISO 20238:2019-05 z wyłączeniem metody: A.1.2, A.2.2, B.1.2, B.2.2","test_object_zh":"输送带"},{"_id":"6a82e7cf884ede9a1b2c420d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe","methodology":"Zagrożenie ogniowe (badania palności):","parameters":[],"technique":"Metody badań znamionowym płomieniem probierczym: 1 kW, 50 W","techniques":["Metody badań znamionowym płomieniem probierczym: 1 kW, 50 W"],"computed":[],"activity":"Zagrożenie ogniowe (badania palności):\nMetody badań znamionowym płomieniem probierczym: 1 kW, 50 W","reference":"PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)","norm_bases":["PN-EN 60695-11-2:2017-11","PN-EN 60332-1-2:2010","PN-EN 60332-1-2:2010/A1:2016-02","PN-EN 60332-1-2:2010/A11:2017-02","PN-EN 60332-1-2:2010/A12:2021-05","PN-EN 60332-2-2:2010","PN-EN 60695-11-10:2014-02","PN-EN 60695-11-10:2014-02/AC:2017-08","PN-EN ISO 9773:2003","PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe Zagrożenie ogniowe (badania palności):\nMetody badań znamionowym płomieniem probierczym: 1 kW, 50 W PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2) Materialy niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz swiatlowodowe Zagrozenie ogniowe (badania palnosci):\nMetody badan znamionowym plomieniem probierczym: 1 kW, 50 W PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)","categories":["materials"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Testing Laboratory PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)","test_object_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables","lab_section_zh":"检测实验室","search_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆 检测实验室 PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 UL 94 p. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)","test_object_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆"},{"_id":"6a82e7cf884ede9a1b2c420e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe","methodology":"Oznaczenie zapalności metodą wskaźnika tlenowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oznaczenie zapalności metodą wskaźnika tlenowego","reference":"PN-EN ISO 4589-2:2017-06","norm_bases":["PN-EN ISO 4589-2:2017-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe Oznaczenie zapalności metodą wskaźnika tlenowego PN-EN ISO 4589-2:2017-06 Materialy niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz swiatlowodowe Oznaczenie zapalnosci metoda wskaznika tlenowego PN-EN ISO 4589-2:2017-06","categories":["materials"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Determination of flammability by the oxygen index method","search_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Determination of flammability by the oxygen index method Testing Laboratory PN-EN ISO 4589-2:2017-06","test_object_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables","lab_section_zh":"检测实验室","search_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆 检测实验室 PN-EN ISO 4589-2:2017-06","test_object_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆"},{"_id":"6a82e7cf884ede9a1b2c420f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe","methodology":"Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym","reference":"PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","norm_bases":["PN-EN 60695-11-5:2017-08","IEC 60695-11-5:2016"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016 Materialy niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz swiatlowodowe Badanie zagrozenia ogniowego (badanie palnosci) plomieniem iglowym PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","categories":["materials"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Fire hazard testing (flammability test) with a needle flame","search_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing (flammability test) with a needle flame Testing Laboratory PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","test_object_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables","lab_section_zh":"检测实验室","search_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆 检测实验室 PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","test_object_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆"},{"_id":"6a82e7cf884ede9a1b2c4210","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe","methodology":"Badanie zagrożenia ogniowego – badanie gorącym drutem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zagrożenia ogniowego – badanie gorącym drutem","reference":"PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021","norm_bases":["PN-EN 60695-2-10:2013-12","PN-EN IEC 60695-2-10:2022-07","PN-EN 60695-2-11:2015-02","PN-EN IEC 60695-2-11:2022-07","PN-EN 60695-2-12:2011","PN-EN 60695-2-12:2011/A1:2014-10","PN-EN IEC 60695-2-12:2022-06","PN-EN 60695-2-13:2011","PN-EN 60695-2-13:2011/A1:2014-10","PN-EN IEC 60695-2-13:2022-05","IEC 60695-2-10:2021","IEC 60695-2-11:2021","IEC 60695-2-12:2021","IEC 60695-2-13:2021"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe Badanie zagrożenia ogniowego – badanie gorącym drutem PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021 Materialy niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz swiatlowodowe Badanie zagrozenia ogniowego – badanie goracym drutem PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021","categories":["materials"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Fire hazard testing – hot wire test","search_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing – hot wire test Testing Laboratory PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021","test_object_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables","lab_section_zh":"检测实验室","search_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆 检测实验室 PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021","test_object_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆"},{"_id":"6a82e7cf884ede9a1b2c4211","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe","methodology":"Badanie zagrożenia ogniowego – nadmierne gorąco","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zagrożenia ogniowego – nadmierne gorąco","reference":"PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014","norm_bases":["PN-EN 60695-10-2:2014-10","IEC 60695-10-2:2014"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz światłowodowe Badanie zagrożenia ogniowego – nadmierne gorąco PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014 Materialy niemetalowe, tworzywa sztuczne w tym: kable i przewody elektryczne oraz swiatlowodowe Badanie zagrozenia ogniowego – nadmierne goraco PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014","categories":["materials"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Fire hazard testing – abnormal heat","search_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing – abnormal heat Testing Laboratory PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014","test_object_en":"Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables","lab_section_zh":"检测实验室","search_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆 检测实验室 PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014","test_object_zh":"非金属材料、塑料，其中包括：电缆、电线与光缆"},{"_id":"6a82e7cf884ede9a1b2c4212","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych","methodology":"Stan powierzchni","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Stan powierzchni\nMetoda wizualna","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych Stan powierzchni\nMetoda wizualna PN-G-15050:2018-01 Siatki okladzinowe zgrzewane obudowy wyrobisk gorniczych Stan powierzchni\nMetoda wizualna PN-G-15050:2018-01","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Welded mesh linings for mine working supports Visual method Testing Laboratory PN-G-15050:2018-01","technique_en":"Visual method","test_object_en":"Welded mesh linings for mine working supports","lab_section_zh":"检测实验室","search_zh":"矿井巷道支护用焊接护网 目视法 检测实验室 PN-G-15050:2018-01","technique_zh":"目视法","test_object_zh":"矿井巷道支护用焊接护网"},{"_id":"6a82e7cf884ede9a1b2c4213","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych","methodology":"Wymiary geometryczne","parameters":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Wymiary geometryczne\nMetoda bezpośrednia","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych Wymiary geometryczne\nMetoda bezpośrednia PN-G-15050:2018-01 Siatki okladzinowe zgrzewane obudowy wyrobisk gorniczych Wymiary geometryczne\nMetoda bezposrednia PN-G-15050:2018-01","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Geometric dimensions","search_en":"Welded mesh linings for mine working supports Geometric dimensions Direct method Testing Laboratory PN-G-15050:2018-01","technique_en":"Direct method","test_object_en":"Welded mesh linings for mine working supports","lab_section_zh":"检测实验室","search_zh":"矿井巷道支护用焊接护网 几何尺寸 直接法 检测实验室 PN-G-15050:2018-01","methodology_zh":"几何尺寸","technique_zh":"直接法","test_object_zh":"矿井巷道支护用焊接护网"},{"_id":"6a82e7cf884ede9a1b2c4214","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych","methodology":"Wytrzymałość siatki na zginanie Sprawdzenie równoważnika Mg","parameters":[{"name":"Zakres obciążeń","range":"do 1000 kN"}],"technique":"Metoda obciążania siłą","techniques":["Metoda obciążania siłą"],"computed":[],"activity":"Wytrzymałość siatki na zginanie Sprawdzenie równoważnika Mg\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych Wytrzymałość siatki na zginanie Sprawdzenie równoważnika Mg\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą PN-G-15050:2018-01 Siatki okladzinowe zgrzewane obudowy wyrobisk gorniczych Wytrzymalosc siatki na zginanie Sprawdzenie rownowaznika Mg\nZakres obciazen do 1000 kN\nMetoda obciazania sila PN-G-15050:2018-01","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Load range","range":"do 1000 kN"}],"search_en":"Welded mesh linings for mine working supports Testing Laboratory Load range PN-G-15050:2018-01","test_object_en":"Welded mesh linings for mine working supports","lab_section_zh":"检测实验室","search_zh":"矿井巷道支护用焊接护网 检测实验室 载荷范围 PN-G-15050:2018-01","parameters_zh":[{"name":"载荷范围","range":"do 1000 kN"}],"test_object_zh":"矿井巷道支护用焊接护网"},{"_id":"6a82e7cf884ede9a1b2c4215","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych","methodology":"Wytrzymałość materiału pręta","parameters":[{"name":"Zakres obciążeń","range":"do 1000 kN"}],"technique":"Metoda obciążania siłą","techniques":["Metoda obciążania siłą"],"computed":[],"activity":"Wytrzymałość materiału pręta\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych Wytrzymałość materiału pręta\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą PN-G-15050:2018-01 Siatki okladzinowe zgrzewane obudowy wyrobisk gorniczych Wytrzymalosc materialu preta\nZakres obciazen do 1000 kN\nMetoda obciazania sila PN-G-15050:2018-01","categories":["materials"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Load range","range":"do 1000 kN"}],"search_en":"Welded mesh linings for mine working supports Testing Laboratory Load range PN-G-15050:2018-01","test_object_en":"Welded mesh linings for mine working supports","lab_section_zh":"检测实验室","search_zh":"矿井巷道支护用焊接护网 检测实验室 载荷范围 PN-G-15050:2018-01","parameters_zh":[{"name":"载荷范围","range":"do 1000 kN"}],"test_object_zh":"矿井巷道支护用焊接护网"},{"_id":"6a82e7cf884ede9a1b2c4216","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych","methodology":"Siła ścinająca zgrzeinę","parameters":[{"name":"Zakres obciążeń","range":"do 1000 kN"}],"technique":"Metoda obciążania siłą","techniques":["Metoda obciążania siłą"],"computed":[],"activity":"Siła ścinająca zgrzeinę\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą","reference":"PN-G-15050:2018-01","norm_bases":["PN-G-15050:2018-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Siatki okładzinowe zgrzewane obudowy wyrobisk górniczych Siła ścinająca zgrzeinę\nZakres obciążeń do 1000 kN\nMetoda obciążania siłą PN-G-15050:2018-01 Siatki okladzinowe zgrzewane obudowy wyrobisk gorniczych Sila scinajaca zgrzeine\nZakres obciazen do 1000 kN\nMetoda obciazania sila PN-G-15050:2018-01","categories":["other"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Load range","range":"do 1000 kN"}],"search_en":"Welded mesh linings for mine working supports Testing Laboratory Load range PN-G-15050:2018-01","test_object_en":"Welded mesh linings for mine working supports","lab_section_zh":"检测实验室","search_zh":"矿井巷道支护用焊接护网 检测实验室 载荷范围 PN-G-15050:2018-01","parameters_zh":[{"name":"载荷范围","range":"do 1000 kN"}],"test_object_zh":"矿井巷道支护用焊接护网"},{"_id":"6a82e7cf884ede9a1b2c4217","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Metale","methodology":"Wytrzymałość na rozciąganie","parameters":[{"name":"siła","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100 mm)"}],"technique":"Metoda obciążania siłą","techniques":["Metoda obciążania siłą"],"computed":[],"activity":"Wytrzymałość na rozciąganie\nZakres:\nsiła (0 - 1000) kN\nWydłużenie (0 - 100 mm)\nMetoda obciążania siłą","reference":"PN-EN ISO 6892-1:2020-05 metoda B","norm_bases":["PN-EN ISO 6892-1:2020-05 metoda B"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale Wytrzymałość na rozciąganie\nZakres:\nsiła (0 - 1000) kN\nWydłużenie (0 - 100 mm)\nMetoda obciążania siłą PN-EN ISO 6892-1:2020-05 metoda B Metale Wytrzymalosc na rozciaganie\nZakres:\nsila (0 - 1000) kN\nWydluzenie (0 - 100 mm)\nMetoda obciazania sila PN-EN ISO 6892-1:2020-05 metoda B","categories":["materials"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Tensile strength","parameters_en":[{"name":"force","range":"(0 - 1000) kN"},{"name":"Elongation","range":"(0 - 100 mm)"}],"search_en":"Metals Tensile strength Testing Laboratory force Elongation PN-EN ISO 6892-1:2020-05 metoda B","test_object_en":"Metals","lab_section_zh":"检测实验室","search_zh":"金属 抗拉强度 检测实验室 力 PN-EN ISO 6892-1:2020-05 metoda B","parameters_zh":[{"name":"力","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100 mm)"}],"methodology_zh":"抗拉强度","test_object_zh":"金属"},{"_id":"6a82e7cf884ede9a1b2c4218","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Metale","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"siła","range":"(0 - 1000) kN"}],"technique":"Metoda obciążania siłą","techniques":["Metoda obciążania siłą"],"computed":[],"activity":"Wytrzymałość na zginanie\nsiła (0 - 1000) kN\nMetoda obciążania siłą","reference":"PN-EN ISO 7438:2021-04","norm_bases":["PN-EN ISO 7438:2021-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale Wytrzymałość na zginanie\nsiła (0 - 1000) kN\nMetoda obciążania siłą PN-EN ISO 7438:2021-04 Metale Wytrzymalosc na zginanie\nsila (0 - 1000) kN\nMetoda obciazania sila PN-EN ISO 7438:2021-04","categories":["materials"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flexural strength","parameters_en":[{"name":"force","range":"(0 - 1000) kN"}],"search_en":"Metals Flexural strength Testing Laboratory force PN-EN ISO 7438:2021-04","test_object_en":"Metals","lab_section_zh":"检测实验室","search_zh":"金属 抗弯强度 检测实验室 力 PN-EN ISO 7438:2021-04","methodology_zh":"抗弯强度","parameters_zh":[{"name":"力","range":"(0 - 1000) kN"}],"test_object_zh":"金属"},{"_id":"6a82e7cf884ede9a1b2c4219","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Metale","methodology":"Praca łamania","parameters":[{"name":"Zakres","range":"KV2 ; KU2"},{"name":"Początkowa energia młota","range":"300J"},{"name":"Temperatura badania","range":"23±5° C"},{"name":"Obniżona","range":"do -50°C"},{"name":"Próba udarności sposobem Charpy’ego"}],"technique":null,"techniques":[],"computed":[],"activity":"Praca łamania\nZakres:\nZakres KV2 ; KU2\nPoczątkowa energia młota 300J\nTemperatura badania 23±5° C\nObniżona do -50°C\nPróba udarności sposobem Charpy’ego","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale Praca łamania\nZakres:\nZakres KV2 ; KU2\nPoczątkowa energia młota 300J\nTemperatura badania 23±5° C\nObniżona do -50°C\nPróba udarności sposobem Charpy’ego PN-EN ISO 148-1:2017-02 Metale Praca lamania\nZakres:\nZakres KV2 ; KU2\nPoczatkowa energia mlota 300J\nTemperatura badania 23±5° C\nObnizona do -50°C\nProba udarnosci sposobem Charpy’ego PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact energy","parameters_en":[{"name":"Range","range":"KV2 ; KU2"},{"name":"Initial hammer energy","range":"300J"},{"name":"Test temperature","range":"23±5° C"},{"name":"Obniżona","range":"do -50°C"},{"name":"Impact strength test by the Charpy method"}],"search_en":"Metals Impact energy Testing Laboratory Range Initial hammer energy Test temperature Impact strength test by the Charpy method PN-EN ISO 148-1:2017-02","test_object_en":"Metals","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"KV2 ; KU2"},{"name":"锤的初始能量","range":"300J"},{"name":"试验温度","range":"23±5° C"},{"name":"Obniżona","range":"do -50°C"},{"name":"夏比冲击试验"}],"search_zh":"金属 断裂功 检测实验室 范围 锤的初始能量 试验温度 夏比冲击试验 PN-EN ISO 148-1:2017-02","methodology_zh":"断裂功","test_object_zh":"金属"},{"_id":"6a82e7cf884ede9a1b2c421a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Jarzma strzemion","methodology":"Wymiary liniowe","parameters":[{"name":"Wytrzymałość na zginanie -siła","range":"do 1000 kN"},{"name":"strzałka ugięcia","range":"do 0,1 m"},{"name":"Rozciąganie śruby"},{"name":"siła","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100) mm"},{"name":"Próba obciążenia nakrętki i śruby kabłąkowej"},{"name":"siła","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100) mm"}],"technique":"Metoda pomiaru bezpośredniego; Metoda obciążenia siłą z pomiarem przemieszczenia; Metoda obciążania siłą; Metoda obciążania siłą","techniques":["Metoda pomiaru bezpośredniego","Metoda obciążenia siłą z pomiarem przemieszczenia","Metoda obciążania siłą","Metoda obciążania siłą"],"computed":[],"activity":"Wymiary liniowe\nZakres:\nWytrzymałość na zginanie -siła do 1000 kN\nstrzałka ugięcia do 0,1 m\nRozciąganie śruby\nsiła (0 - 1000) kN\nWydłużenie (0 - 100) mm\nPróba obciążenia nakrętki i śruby kabłąkowej\nsiła (0 - 1000) kN\nWydłużenie (0 - 100) mm\nMetoda pomiaru bezpośredniego; Metoda obciążenia siłą z pomiarem przemieszczenia; Metoda obciążania siłą; Metoda obciążania siłą","reference":"PN-G-15026:2017-04","norm_bases":["PN-G-15026:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Jarzma strzemion Wymiary liniowe\nZakres:\nWytrzymałość na zginanie -siła do 1000 kN\nstrzałka ugięcia do 0,1 m\nRozciąganie śruby\nsiła (0 - 1000) kN\nWydłużenie (0 - 100) mm\nPróba obciążenia nakrętki i śruby kabłąkowej\nsiła (0 - 1000) kN\nWydłużenie (0 - 100) mm\nMetoda pomiaru bezpośredniego; Metoda obciążenia siłą z pomiarem przemieszczenia; Metoda obciążania siłą; Metoda obciążania siłą PN-G-15026:2017-04 Jarzma strzemion Wymiary liniowe\nZakres:\nWytrzymalosc na zginanie -sila do 1000 kN\nstrzalka ugiecia do 0,1 m\nRozciaganie sruby\nsila (0 - 1000) kN\nWydluzenie (0 - 100) mm\nProba obciazenia nakretki i sruby kablakowej\nsila (0 - 1000) kN\nWydluzenie (0 - 100) mm\nMetoda pomiaru bezposredniego; Metoda obciazenia sila z pomiarem przemieszczenia; Metoda obciazania sila; Metoda obciazania sila PN-G-15026:2017-04","categories":["other"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear dimensions","parameters_en":[{"name":"Wytrzymałość na zginanie -siła","range":"do 1000 kN"},{"name":"deflection","range":"do 0,1 m"},{"name":"Rozciąganie śruby"},{"name":"force","range":"(0 - 1000) kN"},{"name":"Elongation","range":"(0 - 100) mm"},{"name":"Próba obciążenia nakrętki i śruby kabłąkowej"},{"name":"force","range":"(0 - 1000) kN"},{"name":"Elongation","range":"(0 - 100) mm"}],"search_en":"Stirrup yokes Linear dimensions Testing Laboratory deflection force Elongation force Elongation PN-G-15026:2017-04","test_object_en":"Stirrup yokes","lab_section_zh":"检测实验室","search_zh":"线性尺寸 检测实验室 力 力 PN-G-15026:2017-04","parameters_zh":[{"name":"Wytrzymałość na zginanie -siła","range":"do 1000 kN"},{"name":"strzałka ugięcia","range":"do 0,1 m"},{"name":"Rozciąganie śruby"},{"name":"力","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100) mm"},{"name":"Próba obciążenia nakrętki i śruby kabłąkowej"},{"name":"力","range":"(0 - 1000) kN"},{"name":"Wydłużenie","range":"(0 - 100) mm"}],"methodology_zh":"线性尺寸"},{"_id":"6a82e7cf884ede9a1b2c421b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Kotwie górnicze","methodology":"Wymiary liniowe, prostolinijność","parameters":[{"name":"Wytrzymałość żerdzi -na rozciąganie -na zginanie -na ścinanie Zakres","range":"do 1000kN"},{"name":"Wytrzymałość podkładek i nakrętek Zakres","range":"do 1000 kN"}],"technique":"Metoda pomiaru bezpośredniego; Metoda obciążania siłą; Metoda obciążania siłą","techniques":["Metoda pomiaru bezpośredniego","Metoda obciążania siłą","Metoda obciążania siłą"],"computed":[],"activity":"Wymiary liniowe, prostolinijność\nZakres:\nWytrzymałość żerdzi -na rozciąganie -na zginanie -na ścinanie Zakres do 1000kN\nWytrzymałość podkładek i nakrętek Zakres do 1000 kN\nMetoda pomiaru bezpośredniego; Metoda obciążania siłą; Metoda obciążania siłą","reference":"PN-G-15092:1999","norm_bases":["PN-G-15092:1999"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kotwie górnicze Wymiary liniowe, prostolinijność\nZakres:\nWytrzymałość żerdzi -na rozciąganie -na zginanie -na ścinanie Zakres do 1000kN\nWytrzymałość podkładek i nakrętek Zakres do 1000 kN\nMetoda pomiaru bezpośredniego; Metoda obciążania siłą; Metoda obciążania siłą PN-G-15092:1999 Kotwie gornicze Wymiary liniowe, prostolinijnosc\nZakres:\nWytrzymalosc zerdzi -na rozciaganie -na zginanie -na scinanie Zakres do 1000kN\nWytrzymalosc podkladek i nakretek Zakres do 1000 kN\nMetoda pomiaru bezposredniego; Metoda obciazania sila; Metoda obciazania sila PN-G-15092:1999","categories":["other"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Mining bolts Testing Laboratory PN-G-15092:1999","test_object_en":"Mining bolts","lab_section_zh":"检测实验室","search_zh":"矿用锚杆 检测实验室 PN-G-15092:1999","test_object_zh":"矿用锚杆"},{"_id":"6a82e7cf884ede9a1b2c421c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odstępy izolacyjne","parameters":[{"name":"Zakres","range":"0,5 mm - 300 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odstępy izolacyjne\nZakres 0,5 mm - 300 mm","reference":"PN-G-50003:2003","norm_bases":["PN-G-50003:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odstępy izolacyjne\nZakres 0,5 mm - 300 mm PN-G-50003:2003 Maszyny i urzadzenia elektryczne, w tym gornicze Odstepy izolacyjne\nZakres 0,5 mm - 300 mm PN-G-50003:2003","categories":["construction"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Clearances","parameters_en":[{"name":"Range","range":"0,5 mm - 300 mm"}],"search_en":"Electrical machines and equipment, including mining equipment Clearances Testing Laboratory Range PN-G-50003:2003","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0,5 mm - 300 mm"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c421d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Rezystancja izolacji","parameters":[{"name":"Zakres","range":"do 1 TΩ (przy U = 0,5 kV - 2,5 kV)"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja izolacji\nZakres do 1 TΩ (przy U = 0,5 kV - 2,5 kV)","reference":"PN-G-50003:2003 | PN-EN 60204-1:2018-12","norm_bases":["PN-G-50003:2003","PN-EN 60204-1:2018-12"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Rezystancja izolacji\nZakres do 1 TΩ (przy U = 0,5 kV - 2,5 kV) PN-G-50003:2003 | PN-EN 60204-1:2018-12 Maszyny i urzadzenia elektryczne, w tym gornicze Rezystancja izolacji\nZakres do 1 TΩ (przy U = 0,5 kV - 2,5 kV) PN-G-50003:2003 | PN-EN 60204-1:2018-12","categories":["construction"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Insulation resistance","parameters_en":[{"name":"Range","range":"do 1 TΩ (przy U = 0,5 kV - 2,5 kV)"}],"search_en":"Electrical machines and equipment, including mining equipment Insulation resistance Testing Laboratory Range PN-G-50003:2003 | PN-EN 60204-1:2018-12","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 1 TΩ (przy U = 0,5 kV - 2,5 kV)"}],"search_zh":"电气机器与设备，含矿用设备 绝缘电阻 检测实验室 范围 PN-G-50003:2003 | PN-EN 60204-1:2018-12","test_object_zh":"电气机器与设备，含矿用设备","methodology_zh":"绝缘电阻"},{"_id":"6a82e7cf884ede9a1b2c421e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Wytrzymałość elektryczna izolacji,","parameters":[{"name":"napięcie przemienne 0,5 kV - 40 kV"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elektryczna izolacji,\nnapięcie przemienne 0,5 kV - 40 kV","reference":"PN-G-50003:2003 | PN-EN 60204-1:2018-12","norm_bases":["PN-G-50003:2003","PN-EN 60204-1:2018-12"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Wytrzymałość elektryczna izolacji,\nnapięcie przemienne 0,5 kV - 40 kV PN-G-50003:2003 | PN-EN 60204-1:2018-12 Maszyny i urzadzenia elektryczne, w tym gornicze Wytrzymalosc elektryczna izolacji,\nnapiecie przemienne 0,5 kV - 40 kV PN-G-50003:2003 | PN-EN 60204-1:2018-12","categories":["construction"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory PN-G-50003:2003 | PN-EN 60204-1:2018-12","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-G-50003:2003 | PN-EN 60204-1:2018-12","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c421f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność na wilgotne gorąco stałe","parameters":[{"name":"Zakres","range":"do 95°C oraz do 98 % RH"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":"Metoda: próba Cab","techniques":["Metoda: próba Cab"],"computed":[],"activity":"Odporność na wilgotne gorąco stałe\nZakres:\nZakres do 95°C oraz do 98 % RH\nWymiary komory: 1000 mm x 1020 mm x 1413 mm\nMetoda: próba Cab","reference":"PN-G-50003:2003 | PN-EN 60068-2-78:2013-11","norm_bases":["PN-G-50003:2003","PN-EN 60068-2-78:2013-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność na wilgotne gorąco stałe\nZakres:\nZakres do 95°C oraz do 98 % RH\nWymiary komory: 1000 mm x 1020 mm x 1413 mm\nMetoda: próba Cab PN-G-50003:2003 | PN-EN 60068-2-78:2013-11 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc na wilgotne goraco stale\nZakres:\nZakres do 95°C oraz do 98 % RH\nWymiary komory: 1000 mm x 1020 mm x 1413 mm\nMetoda: proba Cab PN-G-50003:2003 | PN-EN 60068-2-78:2013-11","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 95°C oraz do 98 % RH"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory Range PN-G-50003:2003 | PN-EN 60068-2-78:2013-11","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 95°C oraz do 98 % RH"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003 | PN-EN 60068-2-78:2013-11","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4220","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność na zimno","parameters":[{"name":"Zakres","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-G-50003:2003 | PN-EN 60068-2-1:2009","norm_bases":["PN-G-50003:2003","PN-EN 60068-2-1:2009"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-G-50003:2003 | PN-EN 60068-2-1:2009 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc na zimno\nZakres:\nZakres do -50°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-G-50003:2003 | PN-EN 60068-2-1:2009","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Cold resistance","parameters_en":[{"name":"Range","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical machines and equipment, including mining equipment Cold resistance Testing Laboratory Range PN-G-50003:2003 | PN-EN 60068-2-1:2009","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do -50°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003 | PN-EN 60068-2-1:2009","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4221","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność na suche gorąco","parameters":[{"name":"Zakres","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na suche gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-G-50003:2003 | PN-EN 60068-2-2:2009","norm_bases":["PN-G-50003:2003","PN-EN 60068-2-2:2009"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność na suche gorąco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-G-50003:2003 | PN-EN 60068-2-2:2009 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc na suche goraco\nZakres:\nZakres do 180°C\nWymiary komory: 1000 mm x 1020 mm x 1413 mm PN-G-50003:2003 | PN-EN 60068-2-2:2009","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Resistance to dry heat","parameters_en":[{"name":"Range","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_en":"Electrical machines and equipment, including mining equipment Resistance to dry heat Testing Laboratory Range PN-G-50003:2003 | PN-EN 60068-2-2:2009","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 180°C"},{"name":"Wymiary komory: 1000 mm x 1020 mm x 1413 mm"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003 | PN-EN 60068-2-2:2009","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4222","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność na wilgotne gorąco cykliczne, Wymiary komory: 1000 mm x 1020 mm x 1413 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wilgotne gorąco cykliczne, Wymiary komory: 1000 mm x 1020 mm x 1413 mm","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność na wilgotne gorąco cykliczne, Wymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60068-2-30:2008 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc na wilgotne goraco cykliczne, Wymiary komory: 1000 mm x 1020 mm x 1413 mm PN-EN 60068-2-30:2008","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory PN-EN 60068-2-30:2008","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-EN 60068-2-30:2008","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4223","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność na zmianę temperatury, Próba: Na, Nb (do 4 K/min), Nc.","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zmianę temperatury, Próba: Na, Nb (do 4 K/min), Nc.","reference":"PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023","norm_bases":["PN-EN 60068-2-14:2009","PN-EN IEC 60068-2-14:2024-04","IEC 60068-2-14:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność na zmianę temperatury, Próba: Na, Nb (do 4 K/min), Nc. PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc na zmiane temperatury, Proba: Na, Nb (do 4 K/min), Nc. PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4224","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność wyrobów na szkodliwe działania środowiska wysokiej temperatury/wilgotności i zimna, Próba Z/AD: Próba złożona cykliczna temperatura/wilgotność, Wymiary komory: 950 mm x 950 mm x 1100 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność wyrobów na szkodliwe działania środowiska wysokiej temperatury/wilgotności i zimna, Próba Z/AD: Próba złożona cykliczna temperatura/wilgotność, Wymiary komory: 950 mm x 950 mm x 1100 mm","reference":"PN-EN IEC 60068-2-38:2021-12","norm_bases":["PN-EN IEC 60068-2-38:2021-12"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność wyrobów na szkodliwe działania środowiska wysokiej temperatury/wilgotności i zimna, Próba Z/AD: Próba złożona cykliczna temperatura/wilgotność, Wymiary komory: 950 mm x 950 mm x 1100 mm PN-EN IEC 60068-2-38:2021-12 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc wyrobow na szkodliwe dzialania srodowiska wysokiej temperatury/wilgotnosci i zimna, Proba Z/AD: Proba zlozona cykliczna temperatura/wilgotnosc, Wymiary komory: 950 mm x 950 mm x 1100 mm PN-EN IEC 60068-2-38:2021-12","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory PN-EN IEC 60068-2-38:2021-12","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-EN IEC 60068-2-38:2021-12","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4225","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Odporność małych elementów elektrotechnicznych na szkodliwe działanie wilgotnego gorąca, Próba Cy: wilgotne gorąco stałe, próba przyspieszona przeznaczona głównie dla podzespołów, Wymiary komory: 950 mm x 1100 mm x 1475 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność małych elementów elektrotechnicznych na szkodliwe działanie wilgotnego gorąca, Próba Cy: wilgotne gorąco stałe, próba przyspieszona przeznaczona głównie dla podzespołów, Wymiary komory: 950 mm x 1100 mm x 1475 mm","reference":"PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11","norm_bases":["PN-EN 60068-2-67:2004","PN-EN 60068-2-67:2004/A1:2019-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Odporność małych elementów elektrotechnicznych na szkodliwe działanie wilgotnego gorąca, Próba Cy: wilgotne gorąco stałe, próba przyspieszona przeznaczona głównie dla podzespołów, Wymiary komory: 950 mm x 1100 mm x 1475 mm PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11 Maszyny i urzadzenia elektryczne, w tym gornicze Odpornosc malych elementow elektrotechnicznych na szkodliwe dzialanie wilgotnego goraca, Proba Cy: wilgotne goraco stale, proba przyspieszona przeznaczona glownie dla podzespolow, Wymiary komory: 950 mm x 1100 mm x 1475 mm PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4226","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Pomiar temperatury","parameters":[{"name":"Zakres","range":"0°C – 450°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar temperatury\nZakres 0°C – 450°C","reference":"PN-G-50003:2003","norm_bases":["PN-G-50003:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Pomiar temperatury\nZakres 0°C – 450°C PN-G-50003:2003 Maszyny i urzadzenia elektryczne, w tym gornicze Pomiar temperatury\nZakres 0°C – 450°C PN-G-50003:2003","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Temperature measurement","parameters_en":[{"name":"Range","range":"0°C – 450°C"}],"search_en":"Electrical machines and equipment, including mining equipment Temperature measurement Testing Laboratory Range PN-G-50003:2003","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"0°C – 450°C"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4227","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Stopień ochrony IP","parameters":[{"name":"Zakres","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8","reference":"PN-G-50003:2003","norm_bases":["PN-G-50003:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Stopień ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-G-50003:2003 Maszyny i urzadzenia elektryczne, w tym gornicze Stopien ochrony IP\nZakres od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8 PN-G-50003:2003","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"IP degree of protection","parameters_en":[{"name":"Range","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_en":"Electrical machines and equipment, including mining equipment IP degree of protection Testing Laboratory Range PN-G-50003:2003","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"od IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 PN-G-50003:2003","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4228","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Zabezpieczenie przed napięciami szczątkowymi 60 V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zabezpieczenie przed napięciami szczątkowymi 60 V","reference":"PN-EN 60204-1:2018-12","norm_bases":["PN-EN 60204-1:2018-12"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Zabezpieczenie przed napięciami szczątkowymi 60 V PN-EN 60204-1:2018-12 Maszyny i urzadzenia elektryczne, w tym gornicze Zabezpieczenie przed napieciami szczatkowymi 60 V PN-EN 60204-1:2018-12","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Protection against residual voltages 60 V","search_en":"Electrical machines and equipment, including mining equipment Protection against residual voltages 60 V Testing Laboratory PN-EN 60204-1:2018-12","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","search_zh":"电气机器与设备，含矿用设备 检测实验室 PN-EN 60204-1:2018-12","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c4229","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia elektryczne, w tym górnicze","methodology":"Pomiar luminancji","parameters":[{"name":"Zakres","range":"(0,1-12000) cd/m2"},{"name":"Pomiar równomierności luminancji"},{"name":"Zakres","range":"(0-100%)"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar luminancji\nZakres:\nZakres (0,1-12000) cd/m2\nPomiar równomierności luminancji\nZakres (0-100%)","reference":"PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3","norm_bases":["PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia elektryczne, w tym górnicze Pomiar luminancji\nZakres:\nZakres (0,1-12000) cd/m2\nPomiar równomierności luminancji\nZakres (0-100%) PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3 Maszyny i urzadzenia elektryczne, w tym gornicze Pomiar luminancji\nZakres:\nZakres (0,1-12000) cd/m2\nPomiar rownomiernosci luminancji\nZakres (0-100%) PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3","categories":["other"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"(0,1-12000) cd/m2"},{"name":"Pomiar równomierności luminancji"},{"name":"Range","range":"(0-100%)"}],"search_en":"Electrical machines and equipment, including mining equipment Testing Laboratory Range Range PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3","test_object_en":"Electrical machines and equipment, including mining equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1-12000) cd/m2"},{"name":"Pomiar równomierności luminancji"},{"name":"范围","range":"(0-100%)"}],"search_zh":"电气机器与设备，含矿用设备 检测实验室 范围 范围 PN-EN ISO 9241-305:2009 pkt. 6.6.1; 6.6.3","test_object_zh":"电气机器与设备，含矿用设备"},{"_id":"6a82e7cf884ede9a1b2c422a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Odporność na działanie światła dziennego w kontrolowanych warunkach środowiskowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie światła dziennego w kontrolowanych warunkach środowiskowych","reference":"PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02","norm_bases":["PN-EN IEC 60068-2-5:2018","PN-EN ISO 4892-1:2016-06","PN-EN ISO 4892-2:2013-06","PN-EN ISO 4892-2:2013-06/A1:2022-01","PN-EN ISO 16474-1:2014-02","PN-EN ISO 16474-2:2014-02","PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Odporność na działanie światła dziennego w kontrolowanych warunkach środowiskowych PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Odpornosc na dzialanie swiatla dziennego w kontrolowanych warunkach srodowiskowych PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02","categories":["materials","environment","construction"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 PV 3929:2018-03 PV 3930:2017-11 SAE J2527:2004-02"},{"_id":"6a82e7cf884ede9a1b2c422b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Odporność na działanie światła ultrafioletowego w kontrolowanych warunkach środowiskowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie światła ultrafioletowego w kontrolowanych warunkach środowiskowych","reference":"PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02","norm_bases":["PN-EN ISO 4892-3:2016-04","PN-EN ISO 16474-3:2014-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Odporność na działanie światła ultrafioletowego w kontrolowanych warunkach środowiskowych PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Odpornosc na dzialanie swiatla ultrafioletowego w kontrolowanych warunkach srodowiskowych PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02","categories":["materials","environment","construction"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02"},{"_id":"6a82e7cf884ede9a1b2c422c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Odporność na działanie mgły solnej, Próba Ka","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie mgły solnej, Próba Ka","reference":"PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 z wyłączeniem 5.4","norm_bases":["PN-EN IEC 60068-2-11:2021-11","PN-EN 2591-307:2012 z wyłączeniem 5.4"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Odporność na działanie mgły solnej, Próba Ka PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 z wyłączeniem 5.4 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Odpornosc na dzialanie mgly solnej, Proba Ka PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 z wylaczeniem 5.4","categories":["materials","construction"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 z wyłączeniem 5.4","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 z wyłączeniem 5.4"},{"_id":"6a82e7cf884ede9a1b2c422d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Odporność na cykliczne działanie mgły solnej, Próba Kb","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na cykliczne działanie mgły solnej, Próba Kb","reference":"PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2","norm_bases":["PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Odporność na cykliczne działanie mgły solnej, Próba Kb PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Odpornosc na cykliczne dzialanie mgly solnej, Proba Kb PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2","categories":["materials","construction"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN IEC 60068-2-52:2018-05 Test NSS VW 75174:2018-10 Test L18.2"},{"_id":"6a82e7cf884ede9a1b2c422e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Odporność na korozję w sztucznej atmosferze korozyjnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję w sztucznej atmosferze korozyjnej","reference":"PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 BMW AA-0324:2018-04 z wyłączeniem oceny według standardu GS 90010 (pkt. 4.0) | PN-EN 1670:2008","norm_bases":["PN-EN ISO 9227:2023-02 Test NSS","ASTM B117-11 BMW AA-0324:2018-04 z wyłączeniem oceny według standardu GS 90010 (pkt. 4.0)","PN-EN 1670:2008"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Odporność na korozję w sztucznej atmosferze korozyjnej PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 BMW AA-0324:2018-04 z wyłączeniem oceny według standardu GS 90010 (pkt. 4.0) | PN-EN 1670:2008 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Odpornosc na korozje w sztucznej atmosferze korozyjnej PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 BMW AA-0324:2018-04 z wylaczeniem oceny wedlug standardu GS 90010 (pkt. 4.0) | PN-EN 1670:2008","categories":["materials","construction"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 BMW AA-0324:2018-04 z wyłączeniem oceny według standardu GS 90010 (pkt. 4.0) | PN-EN 1670:2008","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 BMW AA-0324:2018-04 z wyłączeniem oceny według standardu GS 90010 (pkt. 4.0) | PN-EN 1670:2008"},{"_id":"6a82e7cf884ede9a1b2c422f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Oznaczenie odporności na cykliczne warunki korozyjne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oznaczenie odporności na cykliczne warunki korozyjne","reference":"PN-EN ISO 11997-1:2017-10 VDA-621-415","norm_bases":["PN-EN ISO 11997-1:2017-10 VDA-621-415"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Oznaczenie odporności na cykliczne warunki korozyjne PN-EN ISO 11997-1:2017-10 VDA-621-415 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Oznaczenie odpornosci na cykliczne warunki korozyjne PN-EN ISO 11997-1:2017-10 VDA-621-415","categories":["materials","construction"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN ISO 11997-1:2017-10 VDA-621-415","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 11997-1:2017-10 VDA-621-415"},{"_id":"6a82e7cf884ede9a1b2c4230","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Ocena stopnia spęcherzenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ocena stopnia spęcherzenia","reference":"PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03","norm_bases":["PN-EN ISO 4628-1:2016-03","PN-EN ISO 4628-2:2016-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Ocena stopnia spęcherzenia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Ocena stopnia specherzenia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03","categories":["materials","construction"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Assessment of degree of blistering","search_en":"Assessment of degree of blistering Testing Laboratory PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03"},{"_id":"6a82e7cf884ede9a1b2c4231","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Ocena stopnia zardzewienia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ocena stopnia zardzewienia","reference":"PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03","norm_bases":["PN-EN ISO 4628-1:2016-03","PN-EN ISO 4628-3:2016-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Ocena stopnia zardzewienia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Ocena stopnia zardzewienia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03","categories":["materials","construction"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Assessment of degree of rusting","search_en":"Assessment of degree of rusting Testing Laboratory PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03"},{"_id":"6a82e7cf884ede9a1b2c4232","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Ocena stopnia spękania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ocena stopnia spękania","reference":"PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03","norm_bases":["PN-EN ISO 4628-1:2016-03","PN-EN ISO 4628-4:2016-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Ocena stopnia spękania PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Ocena stopnia spekania PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03","categories":["materials","construction"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Assessment of degree of cracking","search_en":"Assessment of degree of cracking Testing Laboratory PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03"},{"_id":"6a82e7cf884ede9a1b2c4233","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych","methodology":"Ocena stopnia złuszczenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ocena stopnia złuszczenia","reference":"PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01","norm_bases":["PN-EN ISO 4628-1:2016-03","PN-EN ISO 4628-5:2023-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne, okucia budowlane, elementy maszyn i urządzeń elektrycznych, w tym górniczych Ocena stopnia złuszczenia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01 Wyroby i materialy konstrukcyjne, okucia budowlane, elementy maszyn i urzadzen elektrycznych, w tym gorniczych Ocena stopnia zluszczenia PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01","categories":["materials","construction"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Assessment of degree of flaking","search_en":"Assessment of degree of flaking Testing Laboratory PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01"},{"_id":"6a82e7cf884ede9a1b2c4234","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskonapięciowych","methodology":"Trwałość znakowania, Stopnień ochrony przed zewnętrznymi uderzeniami mechanicznymi (kod IK), Stopień ochrony (kod IP), Stabilność termiczna, Wytrzymałość dielektryczna, Ciągłość obwodu ochronnego, Odporność na korozję","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość znakowania, Stopnień ochrony przed zewnętrznymi uderzeniami mechanicznymi (kod IK), Stopień ochrony (kod IP), Stabilność termiczna, Wytrzymałość dielektryczna, Ciągłość obwodu ochronnego, Odporność na korozję","reference":"PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN 62208:2011","PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Puste obudowy do rozdzielnic i sterownic niskonapięciowych Trwałość znakowania, Stopnień ochrony przed zewnętrznymi uderzeniami mechanicznymi (kod IK), Stopień ochrony (kod IP), Stabilność termiczna, Wytrzymałość dielektryczna, Ciągłość obwodu ochronnego, Odporność na korozję PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskonapieciowych Trwalosc znakowania, Stopnien ochrony przed zewnetrznymi uderzeniami mechanicznymi (kod IK), Stopien ochrony (kod IP), Stabilnosc termiczna, Wytrzymalosc dielektryczna, Ciaglosc obwodu ochronnego, Odpornosc na korozje PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Testing Laboratory PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023"},{"_id":"6a82e7cf884ede9a1b2c4235","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","methodology":"Trwałość znakowania, Stabilność termiczna, Odporność na suche gorąco, Kategoria palności, Wytrzymałość na uderzenie, Stopień ochrony (kod IP), Odstępy izolacyjne powietrzne i powierzchniowe, Skuteczna ciągłość połączeń między dostępnymi częściami przewodzącymi zestawu a obwodem ochronnym, Napięcie wytrzymywane o częstotliwości sieciowej, Graniczne przyrosty temperatur, Wytrzymałość dielektryczna, Odporność na korozję","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość znakowania, Stabilność termiczna, Odporność na suche gorąco, Kategoria palności, Wytrzymałość na uderzenie, Stopień ochrony (kod IP), Odstępy izolacyjne powietrzne i powierzchniowe, Skuteczna ciągłość połączeń między dostępnymi częściami przewodzącymi zestawu a obwodem ochronnym, Napięcie wytrzymywane o częstotliwości sieciowej, Graniczne przyrosty temperatur, Wytrzymałość dielektryczna, Odporność na korozję","reference":"PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN 61439-1:2011","PN-EN IEC 61439-1:2021-10","PN-EN 61439-5:2015-02","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rozdzielnice i sterownice niskonapięciowe Trwałość znakowania, Stabilność termiczna, Odporność na suche gorąco, Kategoria palności, Wytrzymałość na uderzenie, Stopień ochrony (kod IP), Odstępy izolacyjne powietrzne i powierzchniowe, Skuteczna ciągłość połączeń między dostępnymi częściami przewodzącymi zestawu a obwodem ochronnym, Napięcie wytrzymywane o częstotliwości sieciowej, Graniczne przyrosty temperatur, Wytrzymałość dielektryczna, Odporność na korozję PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Trwalosc znakowania, Stabilnosc termiczna, Odpornosc na suche goraco, Kategoria palnosci, Wytrzymalosc na uderzenie, Stopien ochrony (kod IP), Odstepy izolacyjne powietrzne i powierzchniowe, Skuteczna ciaglosc polaczen miedzy dostepnymi czesciami przewodzacymi zestawu a obwodem ochronnym, Napiecie wytrzymywane o czestotliwosci sieciowej, Graniczne przyrosty temperatur, Wytrzymalosc dielektryczna, Odpornosc na korozje PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["construction"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Low-voltage switchgear and controlgear assemblies Testing Laboratory PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_en":"Low-voltage switchgear and controlgear assemblies","lab_section_zh":"检测实验室","search_zh":"低压成套开关设备与控制设备 检测实验室 PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a82e7cf884ede9a1b2c4236","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Węże i przewody z gumy i tworzyw sztucznych","methodology":"Wymiary geometryczne liniowe","parameters":[{"name":"Zakres","range":"do 150 mm"},{"name":"Wytrzymałość na ciśnienie próbne"},{"name":"Zakres","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie rozrywające"},{"name":"Zakres","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie przeciekania"},{"name":"Zakres","range":"do 2500 bar"}],"technique":"Metoda pomiarowa: bezpośrednia; Metoda: obciążenie ciśnieniem statycznym; Metoda: obciążenie ciśnieniem statycznym","techniques":["Metoda pomiarowa: bezpośrednia","Metoda: obciążenie ciśnieniem statycznym","Metoda: obciążenie ciśnieniem statycznym"],"computed":[],"activity":"Wymiary geometryczne liniowe\nZakres:\nZakres do 150 mm\nWytrzymałość na ciśnienie próbne\nZakres do 2500 bar\nWytrzymałość na ciśnienie rozrywające\nZakres do 2500 bar\nWytrzymałość na ciśnienie przeciekania\nZakres do 2500 bar\nMetoda pomiarowa: bezpośrednia; Metoda: obciążenie ciśnieniem statycznym; Metoda: obciążenie ciśnieniem statycznym","reference":"PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012","norm_bases":["PN-EN ISO 4671:2022-09","PN-EN ISO 1402:2021-10","PN-G-32010:2012"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węże i przewody z gumy i tworzyw sztucznych Wymiary geometryczne liniowe\nZakres:\nZakres do 150 mm\nWytrzymałość na ciśnienie próbne\nZakres do 2500 bar\nWytrzymałość na ciśnienie rozrywające\nZakres do 2500 bar\nWytrzymałość na ciśnienie przeciekania\nZakres do 2500 bar\nMetoda pomiarowa: bezpośrednia; Metoda: obciążenie ciśnieniem statycznym; Metoda: obciążenie ciśnieniem statycznym PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012 Weze i przewody z gumy i tworzyw sztucznych Wymiary geometryczne liniowe\nZakres:\nZakres do 150 mm\nWytrzymalosc na cisnienie probne\nZakres do 2500 bar\nWytrzymalosc na cisnienie rozrywajace\nZakres do 2500 bar\nWytrzymalosc na cisnienie przeciekania\nZakres do 2500 bar\nMetoda pomiarowa: bezposrednia; Metoda: obciazenie cisnieniem statycznym; Metoda: obciazenie cisnieniem statycznym PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012","categories":["other"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Linear geometric dimensions","parameters_en":[{"name":"Range","range":"do 150 mm"},{"name":"Wytrzymałość na ciśnienie próbne"},{"name":"Range","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie rozrywające"},{"name":"Range","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie przeciekania"},{"name":"Range","range":"do 2500 bar"}],"search_en":"Rubber and plastics hoses and hose assemblies Linear geometric dimensions Testing Laboratory Range Range Range Range PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012","test_object_en":"Rubber and plastics hoses and hose assemblies","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 150 mm"},{"name":"Wytrzymałość na ciśnienie próbne"},{"name":"范围","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie rozrywające"},{"name":"范围","range":"do 2500 bar"},{"name":"Wytrzymałość na ciśnienie przeciekania"},{"name":"范围","range":"do 2500 bar"}],"search_zh":"橡胶与塑料软管及管路 几何线性尺寸 检测实验室 范围 范围 范围 范围 PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012","methodology_zh":"几何线性尺寸","test_object_zh":"橡胶与塑料软管及管路"},{"_id":"6a82e7cf884ede9a1b2c4237","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Węże i przewody z gumy i tworzyw sztucznych","methodology":"Rezystancja powierzchniowa - pomiar bezpośredni rezystancji","parameters":[{"name":"Zakres","range":"R=1 x 103 - 1 x 1012 Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja powierzchniowa - pomiar bezpośredni rezystancji\nZakres R=1 x 103 - 1 x 1012 Ω","reference":"PN-EN ISO 8031:2021-01","norm_bases":["PN-EN ISO 8031:2021-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węże i przewody z gumy i tworzyw sztucznych Rezystancja powierzchniowa - pomiar bezpośredni rezystancji\nZakres R=1 x 103 - 1 x 1012 Ω PN-EN ISO 8031:2021-01 Weze i przewody z gumy i tworzyw sztucznych Rezystancja powierzchniowa - pomiar bezposredni rezystancji\nZakres R=1 x 103 - 1 x 1012 Ω PN-EN ISO 8031:2021-01","categories":["other"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"R=1 x 103 - 1 x 1012 Ω"}],"search_en":"Rubber and plastics hoses and hose assemblies Testing Laboratory Range PN-EN ISO 8031:2021-01","test_object_en":"Rubber and plastics hoses and hose assemblies","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"R=1 x 103 - 1 x 1012 Ω"}],"search_zh":"橡胶与塑料软管及管路 检测实验室 范围 PN-EN ISO 8031:2021-01","test_object_zh":"橡胶与塑料软管及管路"},{"_id":"6a82e7cf884ede9a1b2c4238","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Węże i przewody z gumy i tworzyw sztucznych","methodology":"Palność","parameters":[{"name":"Czas przyłożenia płomienia 60 s"}],"technique":"Metoda płomieniowa","techniques":["Metoda płomieniowa"],"computed":[],"activity":"Palność\nCzas przyłożenia płomienia 60 s\nMetoda płomieniowa","reference":"PN-EN ISO 8030:2014-09","norm_bases":["PN-EN ISO 8030:2014-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węże i przewody z gumy i tworzyw sztucznych Palność\nCzas przyłożenia płomienia 60 s\nMetoda płomieniowa PN-EN ISO 8030:2014-09 Weze i przewody z gumy i tworzyw sztucznych Palnosc\nCzas przylozenia plomienia 60 s\nMetoda plomieniowa PN-EN ISO 8030:2014-09","categories":["other"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flammability","search_en":"Rubber and plastics hoses and hose assemblies Flammability Flame method Testing Laboratory PN-EN ISO 8030:2014-09","technique_en":"Flame method","test_object_en":"Rubber and plastics hoses and hose assemblies","lab_section_zh":"检测实验室","methodology_zh":"燃烧性","search_zh":"橡胶与塑料软管及管路 燃烧性 检测实验室 PN-EN ISO 8030:2014-09","test_object_zh":"橡胶与塑料软管及管路"},{"_id":"6a82e7cf884ede9a1b2c4239","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Górnicze napędy i sterowania hydrauliczne – złącza wtykowe","methodology":"Minimalne ciśnienie niszczące","parameters":[{"name":"Zakres","range":"do 2500 bar"},{"name":"Wymiary geometryczne"},{"name":"Zakres","range":"do 150 mm"}],"technique":"Metoda: obciążenie ciśnieniem statycznym; Metoda pomiarowa: bezpośrednia","techniques":["Metoda: obciążenie ciśnieniem statycznym","Metoda pomiarowa: bezpośrednia"],"computed":[],"activity":"Minimalne ciśnienie niszczące\nZakres:\nZakres do 2500 bar\nWymiary geometryczne\nZakres do 150 mm\nMetoda: obciążenie ciśnieniem statycznym; Metoda pomiarowa: bezpośrednia","reference":"PN-G-32000:2011 | PN-EN ISO 1402:2021-10","norm_bases":["PN-G-32000:2011","PN-EN ISO 1402:2021-10"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Górnicze napędy i sterowania hydrauliczne – złącza wtykowe Minimalne ciśnienie niszczące\nZakres:\nZakres do 2500 bar\nWymiary geometryczne\nZakres do 150 mm\nMetoda: obciążenie ciśnieniem statycznym; Metoda pomiarowa: bezpośrednia PN-G-32000:2011 | PN-EN ISO 1402:2021-10 Gornicze napedy i sterowania hydrauliczne – zlacza wtykowe Minimalne cisnienie niszczace\nZakres:\nZakres do 2500 bar\nWymiary geometryczne\nZakres do 150 mm\nMetoda: obciazenie cisnieniem statycznym; Metoda pomiarowa: bezposrednia PN-G-32000:2011 | PN-EN ISO 1402:2021-10","categories":["other"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 2500 bar"},{"name":"Geometric dimensions"},{"name":"Range","range":"do 150 mm"}],"search_en":"Mining hydraulic drives and controls – plug-in couplings Testing Laboratory Range Geometric dimensions Range PN-G-32000:2011 | PN-EN ISO 1402:2021-10","test_object_en":"Mining hydraulic drives and controls – plug-in couplings","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 2500 bar"},{"name":"几何尺寸"},{"name":"范围","range":"do 150 mm"}],"search_zh":"检测实验室 范围 几何尺寸 范围 PN-G-32000:2011 | PN-EN ISO 1402:2021-10"},{"_id":"6a82e7cf884ede9a1b2c423a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych","methodology":"Ładowanie elektrostatyczne","parameters":[{"name":"Zakres","range":"do 200 nC"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ładowanie elektrostatyczne\nZakres do 200 nC\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D","norm_bases":["PN-EN 60079-32-2:2015-08","PN-EN 80079-36:2016-07 Annex D"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby z tworzyw sztucznych Ładowanie elektrostatyczne\nZakres do 200 nC\nMetoda pomiarowa bezpośrednia PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D Wyroby z tworzyw sztucznych Ladowanie elektrostatyczne\nZakres do 200 nC\nMetoda pomiarowa bezposrednia PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D","categories":["other"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"Range","range":"do 200 nC"}],"search_en":"Plastic products Direct measurement method Testing Laboratory Range PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D","technique_en":"Direct measurement method","test_object_en":"Plastic products","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"do 200 nC"}],"search_zh":"塑料制品 直接测量法 检测实验室 范围 PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D","technique_zh":"直接测量法","test_object_zh":"塑料制品"},{"_id":"6a82e7cf884ede9a1b2c423b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach i na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach i na zewnątrz Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach i na zewnatrz Natezenie oswietlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10000) lx"}],"search_en":"Workplace environment – indoor and outdoor electric lighting Illuminance Direct measurement method Testing Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor and outdoor electric lighting","lab_section_zh":"检测实验室","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10000) lx"}],"search_zh":"照度 直接测量法 检测实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法"},{"_id":"6a82e7cf884ede9a1b2c423c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach i na zewnątrz","methodology":"Równomierność oświetlenia, Zróżnicowanie oświetlenia (na zewnątrz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia, Zróżnicowanie oświetlenia (na zewnątrz) (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach i na zewnątrz Równomierność oświetlenia, Zróżnicowanie oświetlenia (na zewnątrz) (z obliczeń) PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach i na zewnatrz Rownomiernosc oswietlenia, Zroznicowanie oswietlenia (na zewnatrz) (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Workplace environment – indoor and outdoor electric lighting Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment – indoor and outdoor electric lighting","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-83/E-04040.03"},{"_id":"6a82e7cf884ede9a1b2c423d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 137) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(30 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dźwięku C\nZakres (30 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dźwięku C\nZakres (30 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dzwieku C\nZakres (30 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 3 - punkt 11","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 – 137) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(30 – 140) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Testing Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 – 137) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(30 – 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 检测实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82e7cf884ede9a1b2c423e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas *)","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 137) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","norm_bases":["PN-EN ISO 11202:2012","PN-EN ISO 11202:2012/A1:2021-10","PN-EN ISO 11201:2012"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas *) Równoważny poziom dźwięku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012 Maszyny i urzadzenia – halas *) Rownowazny poziom dzwieku A\nZakres:\nZakres (24 – 137) dB\nSzczytowy poziom dzwieku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 137) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 – 140) dB"}],"search_en":"A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range C-weighted peak sound pressure level Range PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","technique_en":"Direct measurement method","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 137) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 – 140) dB"}],"search_zh":"A 计权等效声级 直接测量法 检测实验室 范围 C 计权峰值声级 范围 PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","technique_zh":"直接测量法"},{"_id":"6a82e7cf884ede9a1b2c423f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas *)","methodology":"Poziom ciśnienia akustycznego emisji (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ciśnienia akustycznego emisji (z obliczeń)","reference":"PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","norm_bases":["PN-EN ISO 11202:2012","PN-EN ISO 11202:2012/A1:2021-10","PN-EN ISO 11201:2012"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas *) Poziom ciśnienia akustycznego emisji (z obliczeń) PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012 Maszyny i urzadzenia – halas *) Poziom cisnienia akustycznego emisji (z obliczen) PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission sound pressure level (calculated)","search_en":"Emission sound pressure level (calculated) Testing Laboratory PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","lab_section_zh":"检测实验室","search_zh":"发射声压级（由计算得出） 检测实验室 PN-EN ISO 11202:2012 | PN-EN ISO 11202:2012/A1:2021-10 | PN-EN ISO 11201:2012","methodology_zh":"发射声压级（由计算得出）"},{"_id":"6a82e7cf884ede9a1b2c4240","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas *)","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09","PN-EN ISO 15744:2008"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas *) Równoważny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008 Maszyny i urzadzenia – halas *) Rownowazny poziom dzwieku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 137) dB"}],"search_en":"A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","technique_en":"Direct measurement method","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 137) dB"}],"search_zh":"A 计权等效声级 直接测量法 检测实验室 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","technique_zh":"直接测量法"},{"_id":"6a82e7cf884ede9a1b2c4241","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas *)","methodology":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09","PN-EN ISO 15744:2008"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas *) Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008 Maszyny i urzadzenia – halas *) Poziom mocy akustycznej, Poziom energii akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sound power level, Sound energy level (calculated)","search_en":"Sound power level, Sound energy level (calculated) Testing Laboratory PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","lab_section_zh":"检测实验室","search_zh":"声功率级、声能量级（由计算得出） 检测实验室 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 | PN-EN ISO 15744:2008","methodology_zh":"声功率级、声能量级（由计算得出）"},{"_id":"6a82e7cf884ede9a1b2c4242","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 137) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 137) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 检测实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a82e7cf884ede9a1b2c4243","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Testing Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment − noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 检测实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a82e7cf884ede9a1b2c4244","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (24 – 137) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 – 137) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Testing Laboratory Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 – 137) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 检测实验室 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a82e7cf884ede9a1b2c4245","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) Testing Laboratory PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） 检测实验室 PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a82e7cf884ede9a1b2c4246","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo przyśpieszenie"},{"name":"drgań"},{"name":"Zakres","range":"(0,1 – 316) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo przyśpieszenie\ndrgań\nZakres (0,1 – 316) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne Skuteczne ważone\nZakres:\nczęstotliwościowo przyśpieszenie\ndrgań\nZakres (0,1 – 316) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone\nZakres:\nczestotliwosciowo przyspieszenie\ndrgan\nZakres (0,1 – 316) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted acceleration"},{"name":"vibration"},{"name":"Range","range":"(0,1 – 316) m/s2"}],"search_en":"Workplace environment – hand-arm mechanical vibration R.m.s. weighted Direct measurement method Testing Laboratory frequency-weighted acceleration vibration Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm mechanical vibration","lab_section_zh":"检测实验室","parameters_zh":[{"name":"częstotliwościowo przyśpieszenie"},{"name":"振动"},{"name":"范围","range":"(0,1 – 316) m/s2"}],"search_zh":"工作环境 － 经上肢作用于人体的机械振动 有效计权 直接测量法 检测实验室 振动 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","methodology_zh":"有效计权","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a82e7cf884ede9a1b2c4247","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) Testing Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm mechanical vibration","lab_section_zh":"检测实验室","search_zh":"工作环境 － 经上肢作用于人体的机械振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） 检测实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a82e7cf884ede9a1b2c4248","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo przyśpieszenie"},{"name":"drgań"},{"name":"Zakres","range":"(0,01 – 316) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo przyśpieszenie\ndrgań\nZakres (0,01 – 316) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka Skuteczne ważone\nZakres:\nczęstotliwościowo przyśpieszenie\ndrgań\nZakres (0,01 – 316) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone\nZakres:\nczestotliwosciowo przyspieszenie\ndrgan\nZakres (0,01 – 316) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted acceleration"},{"name":"vibration"},{"name":"Range","range":"(0,01 – 316) m/s2"}],"search_en":"Workplace environment – whole-body mechanical vibration R.m.s. weighted Direct measurement method Testing Laboratory frequency-weighted acceleration vibration Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body mechanical vibration","lab_section_zh":"检测实验室","parameters_zh":[{"name":"częstotliwościowo przyśpieszenie"},{"name":"振动"},{"name":"范围","range":"(0,01 – 316) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的机械振动 有效计权 直接测量法 检测实验室 振动 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","methodology_zh":"有效计权","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动"},{"_id":"6a82e7cf884ede9a1b2c4249","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) Testing Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body mechanical vibration","lab_section_zh":"检测实验室","search_zh":"工作环境 － 对人体产生全身作用的机械振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） 检测实验室 PN-EN 14253+A1:2011","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动"},{"_id":"6a82e7cf884ede9a1b2c424a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wielkość zabawek lub odłączonych elementów","parameters":[],"technique":"Metoda: próba cylindra do badania małych części","techniques":["Metoda: próba cylindra do badania małych części"],"computed":[],"activity":"Wielkość zabawek lub odłączonych elementów\nMetoda: próba cylindra do badania małych części","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wielkość zabawek lub odłączonych elementów\nMetoda: próba cylindra do badania małych części PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wielkosc zabawek lub odlaczonych elementow\nMetoda: proba cylindra do badania malych czesci PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c424b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wytrzymałość na skręcanie","parameters":[],"technique":"Metoda: próba skręcania","techniques":["Metoda: próba skręcania"],"computed":[],"activity":"Wytrzymałość na skręcanie\nMetoda: próba skręcania","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wytrzymałość na skręcanie\nMetoda: próba skręcania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wytrzymalosc na skrecanie\nMetoda: proba skrecania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Torsional strength","search_en":"Toys Torsional strength Method: torsion test Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_en":"Method: torsion test","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c424c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wytrzymałość na rozciąganie","parameters":[],"technique":"Metoda: próba rozciągania","techniques":["Metoda: próba rozciągania"],"computed":[],"activity":"Wytrzymałość na rozciąganie\nMetoda: próba rozciągania","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wytrzymałość na rozciąganie\nMetoda: próba rozciągania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wytrzymalosc na rozciaganie\nMetoda: proba rozciagania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Tensile strength","search_en":"Toys Tensile strength Method: tensile test Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_en":"Method: tensile test","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 抗拉强度 方法：拉伸试验 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具","methodology_zh":"抗拉强度","technique_zh":"方法：拉伸试验"},{"_id":"6a82e7cf884ede9a1b2c424d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wytrzymałość spadowa","parameters":[],"technique":"Metoda: próba swobodnego spadku","techniques":["Metoda: próba swobodnego spadku"],"computed":[],"activity":"Wytrzymałość spadowa\nMetoda: próba swobodnego spadku","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wytrzymałość spadowa\nMetoda: próba swobodnego spadku PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wytrzymalosc spadowa\nMetoda: proba swobodnego spadku PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c424e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Odporność na uderzenie","parameters":[],"technique":"Metoda: próba uderzeniowa","techniques":["Metoda: próba uderzeniowa"],"computed":[],"activity":"Odporność na uderzenie\nMetoda: próba uderzeniowa","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Odporność na uderzenie\nMetoda: próba uderzeniowa PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Odpornosc na uderzenie\nMetoda: proba uderzeniowa PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact resistance","search_en":"Toys Impact resistance Method: impact test Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_en":"Method: impact test","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 耐冲击性 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具","methodology_zh":"耐冲击性"},{"_id":"6a82e7cf884ede9a1b2c424f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wytrzymałość na ściskanie Metoda: próba ściskania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie Metoda: próba ściskania","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wytrzymałość na ściskanie Metoda: próba ściskania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wytrzymalosc na sciskanie Metoda: proba sciskania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Compressive strength Method: compression test","search_en":"Toys Compressive strength Method: compression test Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4250","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Dostępność części lub elementu zabawki","parameters":[],"technique":"Metoda: próbników","techniques":["Metoda: próbników"],"computed":[],"activity":"Dostępność części lub elementu zabawki\nMetoda: próbników","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Dostępność części lub elementu zabawki\nMetoda: próbników PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Dostepnosc czesci lub elementu zabawki\nMetoda: probnikow PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4251","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Ostrość krawędzi","parameters":[],"technique":"Metoda: taśmy testowej","techniques":["Metoda: taśmy testowej"],"computed":[],"activity":"Ostrość krawędzi\nMetoda: taśmy testowej","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Ostrość krawędzi\nMetoda: taśmy testowej PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Ostrosc krawedzi\nMetoda: tasmy testowej PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sharpness of edges","search_en":"Toys Sharpness of edges Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4252","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Ostrość zakończeń","parameters":[],"technique":"Metoda: badanie głowicą testową","techniques":["Metoda: badanie głowicą testową"],"computed":[],"activity":"Ostrość zakończeń\nMetoda: badanie głowicą testową","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Ostrość zakończeń\nMetoda: badanie głowicą testową PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Ostrosc zakonczen\nMetoda: badanie glowica testowa PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sharpness of points","search_en":"Toys Sharpness of points Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4253","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Giętkość drutów","parameters":[],"technique":"Metoda: próba zginania","techniques":["Metoda: próba zginania"],"computed":[],"activity":"Giętkość drutów\nMetoda: próba zginania","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Giętkość drutów\nMetoda: próba zginania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Gietkosc drutow\nMetoda: proba zginania PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Toys Method: bend test Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_en":"Method: bend test","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 方法：弯曲试验 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具","technique_zh":"方法：弯曲试验"},{"_id":"6a82e7cf884ede9a1b2c4254","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Przeciekanie zabawek wypełnionych cieczą","parameters":[],"technique":"Metoda: test igły","techniques":["Metoda: test igły"],"computed":[],"activity":"Przeciekanie zabawek wypełnionych cieczą\nMetoda: test igły","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Przeciekanie zabawek wypełnionych cieczą\nMetoda: test igły PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Przeciekanie zabawek wypelnionych ciecza\nMetoda: test igly PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Leakage of liquid-filled toys","search_en":"Toys Leakage of liquid-filled toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4255","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Geometryczna forma określonych zabawek","parameters":[],"technique":"Metoda: wzorników kształtu","techniques":["Metoda: wzorników kształtu"],"computed":[],"activity":"Geometryczna forma określonych zabawek\nMetoda: wzorników kształtu","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Geometryczna forma określonych zabawek\nMetoda: wzorników kształtu PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Geometryczna forma okreslonych zabawek\nMetoda: wzornikow ksztaltu PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Geometric shape of certain toys","search_en":"Toys Geometric shape of certain toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4256","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Trwałość zabawek pobudzanych ustami","parameters":[],"technique":"Metoda: próba trwałości","techniques":["Metoda: próba trwałości"],"computed":[],"activity":"Trwałość zabawek pobudzanych ustami\nMetoda: próba trwałości","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Trwałość zabawek pobudzanych ustami\nMetoda: próba trwałości PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Trwalosc zabawek pobudzanych ustami\nMetoda: proba trwalosci PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Toys Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c4257","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Stabilność","parameters":[],"technique":"Metoda: próba stabilności","techniques":["Metoda: próba stabilności"],"computed":[],"activity":"Stabilność\nMetoda: próba stabilności","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Stabilność\nMetoda: próba stabilności PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Stabilnosc\nMetoda: proba stabilnosci PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Stability","search_en":"Toys Stability Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 稳定性 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具","methodology_zh":"稳定性"},{"_id":"6a82e7cf884ede9a1b2c4258","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Wytrzymałość statyczna","parameters":[],"technique":"Metoda: obciążenie statyczne masą","techniques":["Metoda: obciążenie statyczne masą"],"computed":[],"activity":"Wytrzymałość statyczna\nMetoda: obciążenie statyczne masą","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Wytrzymałość statyczna\nMetoda: obciążenie statyczne masą PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Wytrzymalosc statyczna\nMetoda: obciazenie statyczne masa PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["other"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Static strength","search_en":"Toys Static strength Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 静强度 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","test_object_zh":"玩具","methodology_zh":"静强度"},{"_id":"6a82e7cf884ede9a1b2c4259","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Grubość folii z tworzywa sztucznego","parameters":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"computed":[],"activity":"Grubość folii z tworzywa sztucznego\nMetoda: pomiar bezpośredni","reference":"PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","norm_bases":["PN-EN 71-1:2015-01","PN-EN 71-1+A1:2018-08","EN 71-1:2014+A1:2018"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Grubość folii z tworzywa sztucznego\nMetoda: pomiar bezpośredni PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018 Zabawki Grubosc folii z tworzywa sztucznego\nMetoda: pomiar bezposredni PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","categories":["materials"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Thickness of plastic film","search_en":"Toys Thickness of plastic film Method: direct measurement Testing Laboratory PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_en":"Method: direct measurement","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 方法：直接测量 检测实验室 PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018","technique_zh":"方法：直接测量","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c425a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Zabawki","methodology":"Palność:","parameters":[{"name":"czas spalania płomieniowego"},{"name":"maksymalna długość spalonego materiału powyżej punktu przyłożenia"},{"name":"prędkość rozprzestrzeniania płomienia"}],"technique":"Metoda: próba palności","techniques":["Metoda: próba palności"],"computed":[],"activity":"Palność:\nZakres:\nczas spalania płomieniowego\nmaksymalna długość spalonego materiału powyżej punktu przyłożenia\nprędkość rozprzestrzeniania płomienia\nMetoda: próba palności","reference":"PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020","norm_bases":["PN-EN 71-2+A1:2014-06","PN-EN 71-2:2021-05","EN 71-2:2020"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zabawki Palność:\nZakres:\nczas spalania płomieniowego\nmaksymalna długość spalonego materiału powyżej punktu przyłożenia\nprędkość rozprzestrzeniania płomienia\nMetoda: próba palności PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020 Zabawki Palnosc:\nZakres:\nczas spalania plomieniowego\nmaksymalna dlugosc spalonego materialu powyzej punktu przylozenia\npredkosc rozprzestrzeniania plomienia\nMetoda: proba palnosci PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020","categories":["materials"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flammability:","parameters_en":[{"name":"flaming combustion time"},{"name":"maximum length of burnt material above the point of application"},{"name":"flame spread rate"}],"search_en":"Toys Flammability: Method: flammability test Testing Laboratory flaming combustion time maximum length of burnt material above the point of application flame spread rate PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020","technique_en":"Method: flammability test","test_object_en":"Toys","lab_section_zh":"检测实验室","search_zh":"玩具 检测实验室 PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020","test_object_zh":"玩具"},{"_id":"6a82e7cf884ede9a1b2c425b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Sprzęt elektryczny i elektroniczny oraz jego elementy metalowe, polimerowe, ceramiczne, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cd","range":"(50 – 150) mg/kg"},{"name":"Pb","range":"(300 – 1500) mg/kg"},{"name":"Hg","range":"(300 – 1500) mg/kg"},{"name":"Brcałk","range":"(50 – 1500) mg/kg"},{"name":"Crcałk","range":"(300 – 1500) mg/kg"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCd (50 – 150) mg/kg\nPb (300 – 1500) mg/kg\nHg (300 – 1500) mg/kg\nBrcałk (50 – 1500) mg/kg\nCrcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","reference":"PN-EN 62321-3-1:2014-08","norm_bases":["PN-EN 62321-3-1:2014-08"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt elektryczny i elektroniczny oraz jego elementy metalowe, polimerowe, ceramiczne, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego Zawartość pierwiastków\nZakres:\nCd (50 – 150) mg/kg\nPb (300 – 1500) mg/kg\nHg (300 – 1500) mg/kg\nBrcałk (50 – 1500) mg/kg\nCrcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF) PN-EN 62321-3-1:2014-08 Sprzet elektryczny i elektroniczny oraz jego elementy metalowe, polimerowe, ceramiczne, tekstylne, papierowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego Zawartosc pierwiastkow\nZakres:\nCd (50 – 150) mg/kg\nPb (300 – 1500) mg/kg\nHg (300 – 1500) mg/kg\nBrcalk (50 – 1500) mg/kg\nCrcalk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (ED-XRF) PN-EN 62321-3-1:2014-08","categories":["materials","electronics"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Element content","parameters_en":[{"name":"Cd","range":"(50 – 150) mg/kg"},{"name":"Pb","range":"(300 – 1500) mg/kg"},{"name":"Hg","range":"(300 – 1500) mg/kg"},{"name":"Brcałk","range":"(50 – 1500) mg/kg"},{"name":"Crcałk","range":"(300 – 1500) mg/kg"}],"search_en":"Electrical and electronic equipment and its metal, polymer, ceramic, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment Element content Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) Testing Laboratory Cd Pb Hg PN-EN 62321-3-1:2014-08","technique_en":"Energy-dispersive X-ray fluorescence spectrometry (ED-XRF)","test_object_en":"Electrical and electronic equipment and its metal, polymer, ceramic, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment","lab_section_zh":"检测实验室","methodology_zh":"元素含量","parameters_zh":[{"name":"Cd","range":"(50 – 150) mg/kg"},{"name":"Pb","range":"(300 – 1500) mg/kg"},{"name":"Hg","range":"(300 – 1500) mg/kg"},{"name":"Brcałk","range":"(50 – 1500) mg/kg"},{"name":"Crcałk","range":"(300 – 1500) mg/kg"}],"search_zh":"元素含量 能量色散X射线荧光光谱法（ED-XRF） 检测实验室 Cd Pb PN-EN 62321-3-1:2014-08","technique_zh":"能量色散X射线荧光光谱法（ED-XRF）"},{"_id":"6a82e7cf884ede9a1b2c425c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe","methodology":"Badanie oznakowania, Oprzewodowanie wewnętrzne i zewnętrzne, Przystosowanie do uziemienia, Ochrona przed porażeniem prądem elektrycznym, Odporność na działanie pyłu, ciał stałych (IP1X-IP6X) i wody (IPX1-IPX4, IPX5-IPX7), Rezystancja i wytrzymałość elektryczna izolacji, prąd rażeniowy i prąd przewodu ochronnego., Odstępy izolacyjne powierzchniowe i powietrzne, Próba trwałości i próba termiczna, Zaciski gwintowe, Zaciski bezgwintowe i złącza elektryczne, Konstrukcja, Odporność na ciepło, ogień","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie oznakowania, Oprzewodowanie wewnętrzne i zewnętrzne, Przystosowanie do uziemienia, Ochrona przed porażeniem prądem elektrycznym, Odporność na działanie pyłu, ciał stałych (IP1X-IP6X) i wody (IPX1-IPX4, IPX5-IPX7), Rezystancja i wytrzymałość elektryczna izolacji, prąd rażeniowy i prąd przewodu ochronnego., Odstępy izolacyjne powierzchniowe i powietrzne, Próba trwałości i próba termiczna, Zaciski gwintowe, Zaciski bezgwintowe i złącza elektryczne, Konstrukcja, Odporność na ciepło, ogień","reference":"PN-EN IEC 60598-1:2021-07 (z wyłączeniem 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12","norm_bases":["PN-EN IEC 60598-1:2021-07 (z wyłączeniem 4.13.6, 4.20, 4.24)","PN-EN IEC 60598-1:2021-07/A11:2022-12"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe Badanie oznakowania, Oprzewodowanie wewnętrzne i zewnętrzne, Przystosowanie do uziemienia, Ochrona przed porażeniem prądem elektrycznym, Odporność na działanie pyłu, ciał stałych (IP1X-IP6X) i wody (IPX1-IPX4, IPX5-IPX7), Rezystancja i wytrzymałość elektryczna izolacji, prąd rażeniowy i prąd przewodu ochronnego., Odstępy izolacyjne powierzchniowe i powietrzne, Próba trwałości i próba termiczna, Zaciski gwintowe, Zaciski bezgwintowe i złącza elektryczne, Konstrukcja, Odporność na ciepło, ogień PN-EN IEC 60598-1:2021-07 (z wyłączeniem 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12 Oprawy oswietleniowe Badanie oznakowania, Oprzewodowanie wewnetrzne i zewnetrzne, Przystosowanie do uziemienia, Ochrona przed porazeniem pradem elektrycznym, Odpornosc na dzialanie pylu, cial stalych (IP1X-IP6X) i wody (IPX1-IPX4, IPX5-IPX7), Rezystancja i wytrzymalosc elektryczna izolacji, prad razeniowy i prad przewodu ochronnego., Odstepy izolacyjne powierzchniowe i powietrzne, Proba trwalosci i proba termiczna, Zaciski gwintowe, Zaciski bezgwintowe i zlacza elektryczne, Konstrukcja, Odpornosc na cieplo, ogien PN-EN IEC 60598-1:2021-07 (z wylaczeniem 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12","categories":["water","construction"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Luminaires Testing Laboratory PN-EN IEC 60598-1:2021-07 (z wyłączeniem 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12","test_object_en":"Luminaires","lab_section_zh":"检测实验室","search_zh":"灯具 检测实验室 PN-EN IEC 60598-1:2021-07 (z wyłączeniem 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12","test_object_zh":"灯具"},{"_id":"6a82e7cf884ede9a1b2c425d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe stałe ogólnego przeznaczenia","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000","norm_bases":["PN-IEC 598-2-1+A1:1994","PN-IEC 598-2-1+A1:1994/Ap1:2000"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe stałe ogólnego przeznaczenia Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000 Oprawy oswietleniowe stale ogolnego przeznaczenia Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000","categories":["other"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Fixed general purpose luminaires Testing Laboratory PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000","test_object_en":"Fixed general purpose luminaires","lab_section_zh":"检测实验室","search_zh":"通用固定式灯具 检测实验室 PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000","test_object_zh":"通用固定式灯具"},{"_id":"6a82e7cf884ede9a1b2c425e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe wbudowane","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06","norm_bases":["PN-EN 60598-2-2:2012","PN-EN IEC 60598-2-2:2024-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe wbudowane Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06 Oprawy oswietleniowe wbudowane Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06","categories":["other"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Recessed luminaires Testing Laboratory PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06","test_object_en":"Recessed luminaires","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06"},{"_id":"6a82e7cf884ede9a1b2c425f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe drogowe i uliczne","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012","norm_bases":["PN-EN 60598-2-3:2006","PN-EN 60598-2-3:2006/A1:2012"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe drogowe i uliczne Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012 Oprawy oswietleniowe drogowe i uliczne Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012","categories":["other"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Road and street lighting luminaires Testing Laboratory PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012","test_object_en":"Road and street lighting luminaires","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012"},{"_id":"6a82e7cf884ede9a1b2c4260","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy przenośne ogólnego przeznaczenia","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-4:2018-06","norm_bases":["PN-EN 60598-2-4:2018-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy przenośne ogólnego przeznaczenia Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-4:2018-06 Oprawy przenosne ogolnego przeznaczenia Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-4:2018-06","categories":["other"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60598-2-4:2018-06","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-4:2018-06"},{"_id":"6a82e7cf884ede9a1b2c4261","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe z wbudowanymi transformatorami lub przekształtnikami","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-6:2000","norm_bases":["PN-EN 60598-2-6:2000"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe z wbudowanymi transformatorami lub przekształtnikami Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-6:2000 Oprawy oswietleniowe z wbudowanymi transformatorami lub przeksztaltnikami Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-6:2000","categories":["other"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60598-2-6:2000","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-6:2000"},{"_id":"6a82e7cf884ede9a1b2c4262","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Przenośne oprawy oświetleniowe ogrodowe","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-7:2000","norm_bases":["PN-EN 60598-2-7:2000"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośne oprawy oświetleniowe ogrodowe Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-7:2000 Przenosne oprawy oswietleniowe ogrodowe Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-7:2000","categories":["other"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60598-2-7:2000","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-7:2000"},{"_id":"6a82e7cf884ede9a1b2c4263","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Przenośne oprawy oświetleniowe dla dzieci","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006","norm_bases":["PN-EN 60598-2-10:2005","PN-EN 60598-2-10:2005/AC:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośne oprawy oświetleniowe dla dzieci Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006 Przenosne oprawy oswietleniowe dla dzieci Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006","categories":["other"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006"},{"_id":"6a82e7cf884ede9a1b2c4264","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe wbudowane w podłoże","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09","norm_bases":["PN-EN 60598-2-13:2007","PN-EN 60598-2-13:2007/A1:2012","PN-EN 60598-2-13:2007/A2:2017-02","PN-EN 60598-2-13:2007/A11:2021-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe wbudowane w podłoże Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09 Oprawy oswietleniowe wbudowane w podloze Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09","categories":["other"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09"},{"_id":"6a82e7cf884ede9a1b2c4265","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe do oświetlenia awaryjnego","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (z wyłączeniem 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11","norm_bases":["PN-EN 60598-2-22:2015-01","PN-EN 60598-2-22:2015-01/A1:2020-08 (z wyłączeniem 22.17, 22.19)","PN-EN IEC 60598-2-22:2022-11"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe do oświetlenia awaryjnego Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (z wyłączeniem 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11 Oprawy oswietleniowe do oswietlenia awaryjnego Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (z wylaczeniem 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11","categories":["other"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Luminaires for emergency lighting Testing Laboratory PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (z wyłączeniem 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11","test_object_en":"Luminaires for emergency lighting","lab_section_zh":"检测实验室","search_zh":"应急照明用灯具 检测实验室 PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (z wyłączeniem 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11","test_object_zh":"应急照明用灯具"},{"_id":"6a82e7cf884ede9a1b2c4266","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Oprawy oświetleniowe o ograniczonych temperaturach powierzchni","methodology":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12","reference":"PN-EN 60598-2-24:2014-02","norm_bases":["PN-EN 60598-2-24:2014-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawy oświetleniowe o ograniczonych temperaturach powierzchni Cechy i właściwości wg normy przedmiotowej na oprawy oświetleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-24:2014-02 Oprawy oswietleniowe o ograniczonych temperaturach powierzchni Cechy i wlasciwosci wg normy przedmiotowej na oprawy oswietleniowe: PN-EN IEC 60598-1:2021-07 PN-EN IEC 60598-1:2021-07/A11:2022-12 PN-EN 60598-2-24:2014-02","categories":["other"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Luminaires with limited surface temperatures Testing Laboratory PN-EN 60598-2-24:2014-02","test_object_en":"Luminaires with limited surface temperatures","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60598-2-24:2014-02"},{"_id":"6a82e7cf884ede9a1b2c4267","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Elektryczny sprzęt do użytku domowego i podobnego","methodology":"Ochrona przed dostępem do części czynnych, Pobór mocy i prądu, Nagrzewanie, Prąd upływowy i wytrzymałość elektryczna w temperaturze roboczej, Udary napięciowe, Odporność na wilgoć (IPX1-IPX3, IPX4-IPX7), Prąd upływowy i wytrzymałość elektryczna, Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów, Stateczność i zagrożenie mechaniczne, Odstępy izolacyjne powietrzne i powierzchniowe oraz grubość izolacji stałej, Wytrzymałość mechaniczna, Odporność na wysoką temperaturę i żar","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ochrona przed dostępem do części czynnych, Pobór mocy i prądu, Nagrzewanie, Prąd upływowy i wytrzymałość elektryczna w temperaturze roboczej, Udary napięciowe, Odporność na wilgoć (IPX1-IPX3, IPX4-IPX7), Prąd upływowy i wytrzymałość elektryczna, Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów, Stateczność i zagrożenie mechaniczne, Odstępy izolacyjne powietrzne i powierzchniowe oraz grubość izolacji stałej, Wytrzymałość mechaniczna, Odporność na wysoką temperaturę i żar","reference":"PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","norm_bases":["PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","PN-EN 60335-1:2012/A11:2014-10","PN-EN 60335-1:2012/A13:2017-11","PN-EN 60335-1:2012/A1:2019-10","PN-EN 60335-1:2012/A2:2019-11","PN-EN 60335-1:2012/A14:2020-05","PN-EN 60335-1:2012/A15:2022-01","PN-EN IEC 60335-1:2024-04","IEC 60335-1:2020","PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczny sprzęt do użytku domowego i podobnego Ochrona przed dostępem do części czynnych, Pobór mocy i prądu, Nagrzewanie, Prąd upływowy i wytrzymałość elektryczna w temperaturze roboczej, Udary napięciowe, Odporność na wilgoć (IPX1-IPX3, IPX4-IPX7), Prąd upływowy i wytrzymałość elektryczna, Zabezpieczenie przed przeciążeniem transformatorów i obwodów zasilanych z transformatorów, Stateczność i zagrożenie mechaniczne, Odstępy izolacyjne powietrzne i powierzchniowe oraz grubość izolacji stałej, Wytrzymałość mechaniczna, Odporność na wysoką temperaturę i żar PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 Elektryczny sprzet do uzytku domowego i podobnego Ochrona przed dostepem do czesci czynnych, Pobor mocy i pradu, Nagrzewanie, Prad uplywowy i wytrzymalosc elektryczna w temperaturze roboczej, Udary napieciowe, Odpornosc na wilgoc (IPX1-IPX3, IPX4-IPX7), Prad uplywowy i wytrzymalosc elektryczna, Zabezpieczenie przed przeciazeniem transformatorow i obwodow zasilanych z transformatorow, Statecznosc i zagrozenie mechaniczne, Odstepy izolacyjne powietrzne i powierzchniowe oraz grubosc izolacji stalej, Wytrzymalosc mechaniczna, Odpornosc na wysoka temperature i zar PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","categories":["construction"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electrical appliances for household and similar use Testing Laboratory PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","test_object_en":"Electrical appliances for household and similar use","lab_section_zh":"检测实验室","search_zh":"家用及类似用途电器 检测实验室 PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","test_object_zh":"家用及类似用途电器"},{"_id":"6a82e7cf884ede9a1b2c4268","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Odkurzacze i sprzęt czyszczący zasysający wodę","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04","norm_bases":["PN-EN 60335-2-2:2010","PN-EN 60335-2-2:2010/A11:2013-05","PN-EN IEC 60335-2-2:2024-02","PN-EN IEC 60335-2-2:2024-02/A11:2024-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odkurzacze i sprzęt czyszczący zasysający wodę Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04 Odkurzacze i sprzet czyszczacy zasysajacy wode Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04","categories":["other"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Vacuum cleaners and water-suction cleaning equipment Testing Laboratory PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04","test_object_en":"Vacuum cleaners and water-suction cleaning equipment","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04"},{"_id":"6a82e7cf884ede9a1b2c4269","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Żelazka elektryczne","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-3:2016-03","norm_bases":["PN-EN 60335-2-3:2016-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żelazka elektryczne Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-3:2016-03 Zelazka elektryczne Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-3:2016-03","categories":["other"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60335-2-3:2016-03","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-3:2016-03"},{"_id":"6a82e7cf884ede9a1b2c426a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Golarki, maszynki do strzyżenia włosów i podobne urządzenia","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04","norm_bases":["PN-EN 60335-2-8:2015","PN-EN 60335-2-8:2015/A1:2016-04","PN-EN 60335-2-8:2015/A2:2023-02","PN-EN 60335-2-8:2015/A11:2023-01","PN-EN 60335-2-8:2015/A12:2023-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Golarki, maszynki do strzyżenia włosów i podobne urządzenia Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04 Golarki, maszynki do strzyzenia wlosow i podobne urzadzenia Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04","categories":["other"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04"},{"_id":"6a82e7cf884ede9a1b2c426b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Maszyny kuchenne","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06","norm_bases":["PN-EN 60335-2-14:2009","PN-EN 60335-2-14:2009/A1:2009","PN-EN 60335-2-14:2009/A11:2012","PN-EN 60335-2-14:2009/A12:2016-03","PN-EN IEC 60335-2-14:2024-03","PN-EN IEC 60335-2-14:2024-03/A1:2024-06"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny kuchenne Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06 Maszyny kuchenne Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06","categories":["other"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Kitchen machines Testing Laboratory PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06","test_object_en":"Kitchen machines","lab_section_zh":"检测实验室","search_zh":"厨房机械 检测实验室 PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06","test_object_zh":"厨房机械"},{"_id":"6a82e7cf884ede9a1b2c426c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Sprzęt do pielęgnacji skóry i włosów","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02","norm_bases":["PN-EN 60335-2-23:2006 +A1:2008","PN-EN 60335-2-23:2006/A2:2015","PN-EN 60335-2-23:2006/A11:2010E","PN-EN IEC 60335-2-23:2023-10","PN-EN IEC 60335-2-23:2023-10/A1:2023-10","PN-EN IEC 60335-2-23:2023-10/A11:2024-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt do pielęgnacji skóry i włosów Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02 Sprzet do pielegnacji skory i wlosow Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02","categories":["other"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02"},{"_id":"6a82e7cf884ede9a1b2c426d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Ładowarki akumulatorowe","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09","norm_bases":["PN-EN 60335-2-29:2005 +A2:2015-03","PN-EN 60335-2-29:2005/A11:2018-11","PN-EN IEC 60335-2-29:2022-05","PN-EN IEC 60335-2-29:2022-05/A1:2022-06","PN-EN IEC 60335-2-29:2022-05/A11:2024-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ładowarki akumulatorowe Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09 Ladowarki akumulatorowe Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09","categories":["other"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09"},{"_id":"6a82e7cf884ede9a1b2c426e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Ogrzewacze pomieszczeń","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04","norm_bases":["PN-EN 60335-2-30:2010","PN-EN 60335-2-30:2010/A11:2012","PN-EN 60335-2-30:2010/A1:2020-09","PN-EN 60335-2-30:2010/A12:2021-02","PN-EN 60335-2-30:2010/A2:2023-04","PN-EN 60335-2-30:2010/A13:2023-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogrzewacze pomieszczeń Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04 Ogrzewacze pomieszczen Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04","categories":["other"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Room heaters Testing Laboratory PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04","test_object_en":"Room heaters","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04"},{"_id":"6a82e7cf884ede9a1b2c426f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia czyszczące powierzchnię cieczą lub parą","methodology":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30","reference":"PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05","norm_bases":["PN-EN 60335-2-54:2009","PN-EN 60335-2-54:2009/A1:2015-11","PN-EN 60335-2-54:2009/A11:2013-05","PN-EN 60335-2-54:2010/A2:2022-06","PN-EN 60335-2-54:2010/A12:2022-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia czyszczące powierzchnię cieczą lub parą Cechy i właściwości wg normy przedmiotowej na elektryczny sprzęt do użytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05 Urzadzenia czyszczace powierzchnie ciecza lub para Cechy i wlasciwosci wg normy przedmiotowej na elektryczny sprzet do uzytku domowego i podobnego : PN-EN 60335-1:2012 pkt. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1:2012/A11:2014-10 PN-EN 60335-1:2012/A13:2017-11 PN-EN 60335-1:2012/A1:2019-10 PN-EN 60335-1:2012/A2:2019-11 PN-EN 60335-1:2012/A14:2020-05 PN-EN 60335-1:2012/A15:2022-01 PN-EN IEC 60335-1:2024-04 IEC 60335-1:2020 PN-EN IEC 60335-1:2024-04/A11:2024-10 pkt 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05","categories":["other"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05"},{"_id":"6a82e7cf884ede9a1b2c4270","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Badanie narażenia na światło łuku ksenonowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie narażenia na światło łuku ksenonowego","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie narażenia na światło łuku ksenonowego PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie narazenia na swiatlo luku ksenonowego PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Exposure test to xenon arc light","search_en":"Audio/video, information technology and telecommunications equipment Exposure test to xenon arc light Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4271","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Badanie trwałości znakowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie trwałości znakowania","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie trwałości znakowania PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie trwalosci znakowania PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Durability of marking test","search_en":"Audio/video, information technology and telecommunications equipment Durability of marking test Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4272","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Badanie wytrzymałości elektrycznej, Zakres napięcia 0,5 kV - 40 kV","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie wytrzymałości elektrycznej, Zakres napięcia 0,5 kV - 40 kV","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie wytrzymałości elektrycznej, Zakres napięcia 0,5 kV - 40 kV PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie wytrzymalosci elektrycznej, Zakres napiecia 0,5 kV - 40 kV PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Audio/video, information technology and telecommunications equipment Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4273","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Pomiar odstępów izolacyjnych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar odstępów izolacyjnych","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Pomiar odstępów izolacyjnych PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Pomiar odstepow izolacyjnych PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["construction"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Measurement of insulation clearances","search_en":"Audio/video, information technology and telecommunications equipment Measurement of insulation clearances Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4274","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Badanie stopnia ochrony obudowy (IP3X, IP4X, IPX1-IPX8)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie stopnia ochrony obudowy (IP3X, IP4X, IPX1-IPX8)","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie stopnia ochrony obudowy (IP3X, IP4X, IPX1-IPX8) PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie stopnia ochrony obudowy (IP3X, IP4X, IPX1-IPX8) PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Audio/video, information technology and telecommunications equipment Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4275","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie zagrożenia ogniowego (badanie palności) płomieniem igłowym PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Badanie zagrozenia ogniowego (badanie palnosci) plomieniem iglowym PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Fire hazard testing (flammability test) with a needle flame","search_en":"Audio/video, information technology and telecommunications equipment Fire hazard testing (flammability test) with a needle flame Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4276","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Klasyfikacja palności materiałów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Klasyfikacja palności materiałów","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Klasyfikacja palności materiałów PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Klasyfikacja palnosci materialow PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["materials"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flammability classification of materials","search_en":"Audio/video, information technology and telecommunications equipment Flammability classification of materials Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4277","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Wytrzymałości na działanie siłą","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałości na działanie siłą","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Wytrzymałości na działanie siłą PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Wytrzymalosci na dzialanie sila PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Strength under the action of a force","search_en":"Audio/video, information technology and telecommunications equipment Strength under the action of a force Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4278","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Próba udarności (udarowa) na obudowie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba udarności (udarowa) na obudowie","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Próba udarności (udarowa) na obudowie PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Proba udarnosci (udarowa) na obudowie PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Impact test on the enclosure","search_en":"Audio/video, information technology and telecommunications equipment Impact test on the enclosure Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c4279","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Próba spadowa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba spadowa","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Próba spadowa PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Proba spadowa PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Drop test","search_en":"Audio/video, information technology and telecommunications equipment Drop test Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c427a","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","methodology":"Nagrzewanie - pomiar temperatury","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nagrzewanie - pomiar temperatury","reference":"PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","norm_bases":["PN-EN IEC 62368-1:2020-11","PN-EN IEC 62368-1:2024-06","IEC 62368-1:2023","PN-EN 60950-1:2007","PN-EN 62368-1:2015-03","PN-EN 62368-1:2015-03/A11:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Nagrzewanie - pomiar temperatury PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Nagrzewanie - pomiar temperatury PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","categories":["other"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Heating - temperature measurement","search_en":"Audio/video, information technology and telecommunications equipment Heating - temperature measurement Testing Laboratory PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_en":"Audio/video, information technology and telecommunications equipment","lab_section_zh":"检测实验室","search_zh":"音频/视频、信息技术与电信设备 检测实验室 PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a82e7cf884ede9a1b2c427b","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Tworzywa sztuczne","methodology":"Oznaczanie właściwości mechanicznych przy statycznym rozciąganiu","parameters":[{"name":"wytrzymałość na rozciąganie"},{"name":"odkształcenie nominalne"}],"technique":null,"techniques":[],"computed":[],"activity":"Oznaczanie właściwości mechanicznych przy statycznym rozciąganiu\nZakres:\nwytrzymałość na rozciąganie\nodkształcenie nominalne","reference":"PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10","norm_bases":["PN-EN ISO 527-1:2020-01","PN-EN ISO 527-2:2012","PN-EN ISO 527-2:2012/Ap1:2013-09","PN-EN ISO 527-4:2022-06","PN-EN ISO 527-4:2023-10"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tworzywa sztuczne Oznaczanie właściwości mechanicznych przy statycznym rozciąganiu\nZakres:\nwytrzymałość na rozciąganie\nodkształcenie nominalne PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10 Tworzywa sztuczne Oznaczanie wlasciwosci mechanicznych przy statycznym rozciaganiu\nZakres:\nwytrzymalosc na rozciaganie\nodksztalcenie nominalne PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10","categories":["materials"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","parameters_en":[{"name":"tensile strength"},{"name":"odkształcenie nominalne"}],"search_en":"Plastics Testing Laboratory tensile strength PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10","test_object_en":"Plastics","lab_section_zh":"检测实验室","search_zh":"塑料 检测实验室 抗拉强度 PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10","test_object_zh":"塑料","parameters_zh":[{"name":"抗拉强度"},{"name":"odkształcenie nominalne"}]},{"_id":"6a82e7cf884ede9a1b2c427c","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","methodology":"Moc pobierana, Wilgotnościowe stabilizowanie wstępne, Trwałość oznakowania, Impedancja i zdolność przewodzenia prądu, Wytrzymałość elektryczna, Wytrzymałość mechaniczna i odporność na ciepło, Odstępy wypełnione masą izolacyjną, Pomiar odstępów izolacyjnych powierzchniowych i powietrznych, Niestabilność – utrata równowagi, Badanie stopnia ochrony IP, Prób nacisku, Próba udaru, Próba spadku, Wytrzymałość mechaniczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc pobierana, Wilgotnościowe stabilizowanie wstępne, Trwałość oznakowania, Impedancja i zdolność przewodzenia prądu, Wytrzymałość elektryczna, Wytrzymałość mechaniczna i odporność na ciepło, Odstępy wypełnione masą izolacyjną, Pomiar odstępów izolacyjnych powierzchniowych i powietrznych, Niestabilność – utrata równowagi, Badanie stopnia ochrony IP, Prób nacisku, Próba udaru, Próba spadku, Wytrzymałość mechaniczna","reference":"PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03","norm_bases":["PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2;","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Medyczne urządzenia elektryczne Moc pobierana, Wilgotnościowe stabilizowanie wstępne, Trwałość oznakowania, Impedancja i zdolność przewodzenia prądu, Wytrzymałość elektryczna, Wytrzymałość mechaniczna i odporność na ciepło, Odstępy wypełnione masą izolacyjną, Pomiar odstępów izolacyjnych powierzchniowych i powietrznych, Niestabilność – utrata równowagi, Badanie stopnia ochrony IP, Prób nacisku, Próba udaru, Próba spadku, Wytrzymałość mechaniczna PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 Medyczne urzadzenia elektryczne Moc pobierana, Wilgotnosciowe stabilizowanie wstepne, Trwalosc oznakowania, Impedancja i zdolnosc przewodzenia pradu, Wytrzymalosc elektryczna, Wytrzymalosc mechaniczna i odpornosc na cieplo, Odstepy wypelnione masa izolacyjna, Pomiar odstepow izolacyjnych powierzchniowych i powietrznych, Niestabilnosc – utrata rownowagi, Badanie stopnia ochrony IP, Prob nacisku, Proba udaru, Proba spadku, Wytrzymalosc mechaniczna PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03","categories":["construction"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Medical electrical equipment Testing Laboratory PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03","test_object_en":"Medical electrical equipment","lab_section_zh":"检测实验室","search_zh":"医用电气设备 检测实验室 PN-EN 60601-1:2011 pkt. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03","test_object_zh":"医用电气设备"},{"_id":"6a82e7cf884ede9a1b2c427d","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Stacje ładowania akumulatorów pojazdów elektrycznych przy zasilaniu z sieci prądu przemiennego","methodology":"Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania","reference":"PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002","norm_bases":["PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5","PN-EN IEC 61851-1:2019-10/AC:2024-02","PN-EN 61851-22:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje ładowania akumulatorów pojazdów elektrycznych przy zasilaniu z sieci prądu przemiennego Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002 Stacje ladowania akumulatorow pojazdow elektrycznych przy zasilaniu z sieci pradu przemiennego Opornosc izolacji, Prad dotykowy, Wytrzymywanie napiecia pradu zmiennego, Badanie trwalosci oznakowania PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002","categories":["construction","automotive"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Electric vehicle battery charging stations supplied from AC mains Testing Laboratory PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002","test_object_en":"Electric vehicle battery charging stations supplied from AC mains","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002"},{"_id":"6a82e7cf884ede9a1b2c427e","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Stacje ładowania pojazdów elektrycznych prądu stałego","methodology":"Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania","reference":"PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08","norm_bases":["PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5","PN-EN IEC 61851-1:2019-10/AC:2024-02","PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7","PN-EN 61851-23:2014-11/AC:2016-08"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stacje ładowania pojazdów elektrycznych prądu stałego Oporność izolacji, Prąd dotykowy, Wytrzymywanie napięcia prądu zmiennego, Badanie trwałości oznakowania PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08 Stacje ladowania pojazdow elektrycznych pradu stalego Opornosc izolacji, Prad dotykowy, Wytrzymywanie napiecia pradu zmiennego, Badanie trwalosci oznakowania PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08","categories":["construction","automotive"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN IEC 61851-1:2019-10 pkt: 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 Pkt: 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08"},{"_id":"6a82e7cf884ede9a1b2c427f","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Narzędzia o napędzie elektrycznym, ręczne, przenośne, do trawników i inne ogrodnicze","methodology":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","reference":"PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02","norm_bases":["PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28","PN-EN 62841-1:2015-11/AC:2016-01","PN-EN 62841-1:2015-11/A11:2023-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Narzędzia o napędzie elektrycznym, ręczne, przenośne, do trawników i inne ogrodnicze Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 Narzedzia o napedzie elektrycznym, reczne, przenosne, do trawnikow i inne ogrodnicze Prad wejsciowy, Nagrzewanie, Odpornosc na cieplo i ogien, Odpornosc mechaniczna, Ciaglosc uziemienia, Odstepy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02","categories":["construction"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02"},{"_id":"6a82e7cf884ede9a1b2c4280","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Ręczne wiertarki i wiertarki udarowe","methodology":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","reference":"PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05","norm_bases":["PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28","PN-EN 62841-1:2015-11/AC:2016-01","PN-EN 62841-1:2015-11/A11:2023-02","PN-EN 62841-1-2-1:2018-03","PN-EN 62841-1-2-1:2018-03/A11:2020-03","PN-EN 62841-1-2-1:2018-03/A1:2023-04","PN-EN 62841-1-2-1:2018-03/A12:2023-05"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ręczne wiertarki i wiertarki udarowe Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05 Reczne wiertarki i wiertarki udarowe Prad wejsciowy, Nagrzewanie, Odpornosc na cieplo i ogien, Odpornosc mechaniczna, Ciaglosc uziemienia, Odstepy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05","categories":["construction"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05"},{"_id":"6a82e7cf884ede9a1b2c4281","lab_id":"69ad52a3de79e566650fb81c","country":"PL","accr_number":"AB 1552","accr_body":"PCA","test_object":"Wkrętarki ręczne i klucze udarowe","methodology":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne","reference":"PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01","norm_bases":["PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28","PN-EN 62841-1:2015-11/AC:2016-01","PN-EN 62841-1:2015-11/A11:2023-02","PN-EN 62841-1-2-2:2015-03","PN-EN 62841-1-2-2:2015-03/AC:2016-01"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wkrętarki ręczne i klucze udarowe Prąd wejściowy, Nagrzewanie, Odporność na ciepło i ogień, Odporność mechaniczna, Ciągłość uziemienia, Odstępy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01 Wkretarki reczne i klucze udarowe Prad wejsciowy, Nagrzewanie, Odpornosc na cieplo i ogien, Odpornosc mechaniczna, Ciaglosc uziemienia, Odstepy izolacyjne PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01","categories":["construction"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"Testing Laboratory PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01","lab_section_zh":"检测实验室","search_zh":"检测实验室 PN-EN 62841-1:2015-11 Pkt: 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01"}],"has_pdf":true}