{"lab":{"_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","address":"ul. Mostowa 9a, 64-800 Chodzież","categories":["water","environment","materials","microbiology"],"city":"Chodzież","imported_at":"2026-03-08T10:42:43.265Z","methods_count":95,"name":"ARQUES Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1539.pdf"],"scope_summary":"","search_text":"arques sp. z o.o. ul. mostowa 9a, 64-800 chodzież environment other materials water microbiology food pharma electronics automotive construction","status":"active","updated_at":"2026-03-08T14:50:41.061Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:49:44.555Z","email_confidence":"high","email_mx":true,"email_source":"https://arques.pl/laboratorium-badawcze/","parse_date":"2026-08-17T10:49:44.555Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, osadów, odpadów","en":"Microbiological tests and sampling of water, drinking water, sediments, waste"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"15","date":"07.07.2026"},"map_coord":[52.998072,16.90849],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/4bc8cf95f2d097e36572cb0e4ae22716/AB%201539.pdf","has_en":true,"category_counts":{"water":73,"environment":37,"materials":7,"microbiology":6,"petro":1,"food":1,"construction":1},"category_scores":{"water":42.29,"environment":10.87,"materials":0.39,"microbiology":0.29,"petro":0.01,"food":0.01,"construction":0.01},"has_zh":true},"methods":[{"_id":"6a82e748884ede9a1b2c40d4","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007 z wył. p. 8 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007 z wył. p. 8","PN-ISO 10381-5:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 z wył. p. 8 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 z wyl. p. 8 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007 z wył. p. 8 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-4:2007 z wył. p. 8 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a82e748884ede9a1b2c40d5","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w KCl, w H2O","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w KCl, w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w KCl, w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w KCl, w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Soil Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a82e748884ede9a1b2c40d6","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(1,0 – 100) mg/kg"},{"name":"Cd","range":"(0,50 – 7,0) mg/kg"},{"name":"Ni","range":"(1,0 – 100) mg/kg"},{"name":"Zn","range":"(1,0 – 500) mg/kg"},{"name":"Cu","range":"(1,0 – 150) mg/kg"},{"name":"Cr","range":"(1,0 – 250) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (1,0 – 100) mg/kg\nCd (0,50 – 7,0) mg/kg\nNi (1,0 – 100) mg/kg\nZn (1,0 – 500) mg/kg\nCu (1,0 – 150) mg/kg\nCr (1,0 – 250) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 11047:2001","norm_bases":["PN-ISO 11047:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali\nZakres:\nPb (1,0 – 100) mg/kg\nCd (0,50 – 7,0) mg/kg\nNi (1,0 – 100) mg/kg\nZn (1,0 – 500) mg/kg\nCu (1,0 – 150) mg/kg\nCr (1,0 – 250) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 Gleba Zawartosc metali\nZakres:\nPb (1,0 – 100) mg/kg\nCd (0,50 – 7,0) mg/kg\nNi (1,0 – 100) mg/kg\nZn (1,0 – 500) mg/kg\nCu (1,0 – 150) mg/kg\nCr (1,0 – 250) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001","categories":["materials","environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(1,0 – 100) mg/kg"},{"name":"Cd","range":"(0,50 – 7,0) mg/kg"},{"name":"Ni","range":"(1,0 – 100) mg/kg"},{"name":"Zn","range":"(1,0 – 500) mg/kg"},{"name":"Cu","range":"(1,0 – 150) mg/kg"},{"name":"Cr","range":"(1,0 – 250) mg/kg"}],"search_en":"Soil Metal content Flame atomic absorption spectrometry (FAAS) Pb Cd Ni Zn Cu Cr PN-ISO 11047:2001","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Soil","parameters_zh":[{"name":"Pb","range":"(1,0 – 100) mg/kg"},{"name":"Cd","range":"(0,50 – 7,0) mg/kg"},{"name":"Ni","range":"(1,0 – 100) mg/kg"},{"name":"Zn","range":"(1,0 – 500) mg/kg"},{"name":"Cu","range":"(1,0 – 150) mg/kg"},{"name":"Cr","range":"(1,0 – 250) mg/kg"}],"search_zh":"土壤 金属含量 火焰原子吸收光谱法（FAAS） Pb Cd Ni Zn Cu Cr PN-ISO 11047:2001","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"土壤","methodology_zh":"金属含量"},{"_id":"6a82e748884ede9a1b2c40d7","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,050 – 2,50) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,050 – 2,50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-ISO 16772:2009","norm_bases":["PN-ISO 16772:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość rtęci\nZakres (0,050 – 2,50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009 Gleba Zawartosc rteci\nZakres (0,050 – 2,50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,050 – 2,50) mg/kg"}],"search_en":"Soil Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-ISO 16772:2009","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Soil","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,050 – 2,50) mg/kg"}],"search_zh":"土壤 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-ISO 16772:2009","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤"},{"_id":"6a82e748884ede9a1b2c40d8","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (1,0 – 50,0) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PB-01 edycja 2 z dnia 25.01.2021 r.","norm_bases":["PB-01 edycja 2 z dnia 25.01.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fosforu przyswajalnego\nZakres (1,0 – 50,0) mg/100g P2O5\nMetoda spektrofotometryczna PB-01 edycja 2 z dnia 25.01.2021 r. Gleba Zawartosc fosforu przyswajalnego\nZakres (1,0 – 50,0) mg/100g P2O5\nMetoda spektrofotometryczna PB-01 edycja 2 z dnia 25.01.2021 r.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) mg/100g P2O5"}],"search_en":"Soil Available phosphorus content Spectrophotometric method Range PB-01 edycja 2 z dnia 25.01.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) mg/100g P2O5"}],"search_zh":"土壤 有效磷含量 分光光度法 范围 PB-01 edycja 2 z dnia 25.01.2021 r.","technique_zh":"分光光度法","test_object_zh":"土壤","methodology_zh":"有效磷含量"},{"_id":"6a82e748884ede9a1b2c40d9","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(20,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (20,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość suchej masy\nZakres (20,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Gleba Zawartosc suchej masy\nZakres (20,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(20,0 – 99,9) %"}],"search_en":"Soil Dry matter content Gravimetric method Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(20,0 – 99,9) %"}],"search_zh":"土壤 干物质含量 重量法 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量"},{"_id":"6a82e748884ede9a1b2c40da","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Straty przy prażeniu","parameters":[{"name":"Zakres","range":"(5,0 – 75,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu\nZakres (5,0 – 75,0) %\nMetoda wagowa","reference":"PB-10 edycja 2 z dnia 25.01.2021 r.","norm_bases":["PB-10 edycja 2 z dnia 25.01.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Straty przy prażeniu\nZakres (5,0 – 75,0) %\nMetoda wagowa PB-10 edycja 2 z dnia 25.01.2021 r. Gleba Straty przy prazeniu\nZakres (5,0 – 75,0) %\nMetoda wagowa PB-10 edycja 2 z dnia 25.01.2021 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(5,0 – 75,0) %"}],"search_en":"Soil Loss on ignition Gravimetric method Range PB-10 edycja 2 z dnia 25.01.2021 r.","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(5,0 – 75,0) %"}],"search_zh":"土壤 烧失量 重量法 范围 PB-10 edycja 2 z dnia 25.01.2021 r.","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"烧失量"},{"_id":"6a82e748884ede9a1b2c40db","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(1,0 – 1000) mg/kg"},{"name":"Cd","range":"(0,50 – 10,0) mg/kg"},{"name":"Ni","range":"(1,0 – 200) mg/kg"},{"name":"Zn","range":"(1,0 – 2000) mg/kg"},{"name":"Cu","range":"(1,0 – 250) mg/kg"},{"name":"Cr","range":"(1,0 – 500) mg/kg"},{"name":"Hg","range":"(0,050 – 2,50) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (1,0 – 1000) mg/kg\nCd (0,50 – 10,0) mg/kg\nNi (1,0 – 200) mg/kg\nZn (1,0 – 2000) mg/kg\nCu (1,0 – 250) mg/kg\nCr (1,0 – 500) mg/kg\nHg (0,050 – 2,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","norm_bases":["PN-EN 16174:2012","PN-EN ISO 22036:2024-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali\nZakres:\nPb (1,0 – 1000) mg/kg\nCd (0,50 – 10,0) mg/kg\nNi (1,0 – 200) mg/kg\nZn (1,0 – 2000) mg/kg\nCu (1,0 – 250) mg/kg\nCr (1,0 – 500) mg/kg\nHg (0,050 – 2,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07 Gleba Zawartosc metali\nZakres:\nPb (1,0 – 1000) mg/kg\nCd (0,50 – 10,0) mg/kg\nNi (1,0 – 200) mg/kg\nZn (1,0 – 2000) mg/kg\nCu (1,0 – 250) mg/kg\nCr (1,0 – 500) mg/kg\nHg (0,050 – 2,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","categories":["materials","environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(1,0 – 1000) mg/kg"},{"name":"Cd","range":"(0,50 – 10,0) mg/kg"},{"name":"Ni","range":"(1,0 – 200) mg/kg"},{"name":"Zn","range":"(1,0 – 2000) mg/kg"},{"name":"Cu","range":"(1,0 – 250) mg/kg"},{"name":"Cr","range":"(1,0 – 500) mg/kg"},{"name":"Hg","range":"(0,050 – 2,50) mg/kg"}],"search_en":"Soil Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Cd Ni Zn Cu Cr Hg PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","parameters_zh":[{"name":"Pb","range":"(1,0 – 1000) mg/kg"},{"name":"Cd","range":"(0,50 – 10,0) mg/kg"},{"name":"Ni","range":"(1,0 – 200) mg/kg"},{"name":"Zn","range":"(1,0 – 2000) mg/kg"},{"name":"Cu","range":"(1,0 – 250) mg/kg"},{"name":"Cr","range":"(1,0 – 500) mg/kg"},{"name":"Hg","range":"(0,050 – 2,50) mg/kg"}],"search_zh":"土壤 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） Pb Cd Ni Zn Cu Cr PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤","methodology_zh":"金属含量"},{"_id":"6a82e748884ede9a1b2c40dc","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (1,0 – 100) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość fosforu przyswajalnego\nZakres (1,0 – 100) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc fosforu przyswajalnego\nZakres (1,0 – 100) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/100g P2O5"}],"search_en":"Mineral soil Available phosphorus content Spectrophotometric method Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/100g P2O5"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"矿质土壤","methodology_zh":"有效磷含量"},{"_id":"6a82e748884ede9a1b2c40dd","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) mg/100g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04020:1994+Az1:2004","norm_bases":["PN-R-04020:1994+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994+Az1:2004 Gleba mineralna Zawartosc magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994+Az1:2004","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) mg/100g"}],"search_en":"Mineral soil Available magnesium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04020:1994+Az1:2004","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) mg/100g"}],"search_zh":"矿质土壤 有效镁含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04020:1994+Az1:2004","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","methodology_zh":"有效镁含量"},{"_id":"6a82e748884ede9a1b2c40de","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) mg/100g K2O"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04022:1996","norm_bases":["PN-R-04022:1996"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04022:1996 Gleba mineralna Zawartosc potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04022:1996","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) mg/100g K2O"}],"search_en":"Mineral soil Available potassium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04022:1996","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) mg/100g K2O"}],"search_zh":"矿质土壤 速效钾含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04022:1996","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","methodology_zh":"速效钾含量"},{"_id":"6a82e748884ede9a1b2c40df","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) mg/100g"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04020:1994+Az1:2004","PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009 Gleba mineralna Zawartosc magnezu przyswajalnego\nZakres (1,0 – 30,0) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) mg/100g"}],"search_en":"Mineral soil Available magnesium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) mg/100g"}],"search_zh":"矿质土壤 有效镁含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"矿质土壤","methodology_zh":"有效镁含量"},{"_id":"6a82e748884ede9a1b2c40e0","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) mg/100g K2O"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04022:1996 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04022:1996","PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04022:1996 | PN-EN ISO 11885:2009 Gleba mineralna Zawartosc potasu przyswajalnego\nZakres (1,0 – 50,0) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04022:1996 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) mg/100g K2O"}],"search_en":"Mineral soil Available potassium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04022:1996 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) mg/100g K2O"}],"search_zh":"矿质土壤 速效钾含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04022:1996 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"矿质土壤","methodology_zh":"速效钾含量"},{"_id":"6a82e748884ede9a1b2c40e1","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(12,5 – 450) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (12,5 – 450) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość fosforu przyswajalnego\nZakres (12,5 – 450) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997 Gleba organiczna Zawartosc fosforu przyswajalnego\nZakres (12,5 – 450) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(12,5 – 450) mg/100g P2O5"}],"search_en":"Organic soil Available phosphorus content Spectrophotometric method Range PN-R-04024:1997","technique_en":"Spectrophotometric method","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(12,5 – 450) mg/100g P2O5"}],"search_zh":"有机土壤 有效磷含量 分光光度法 范围 PN-R-04024:1997","technique_zh":"分光光度法","test_object_zh":"有机土壤","methodology_zh":"有效磷含量"},{"_id":"6a82e748884ede9a1b2c40e2","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(10,0 – 200,0) mg/100g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (10,0 – 200,0) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość magnezu przyswajalnego\nZakres (10,0 – 200,0) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997 Gleba organiczna Zawartosc magnezu przyswajalnego\nZakres (10,0 – 200,0) mg/100g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(10,0 – 200,0) mg/100g"}],"search_en":"Organic soil Available magnesium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04024:1997","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10,0 – 200,0) mg/100g"}],"search_zh":"有机土壤 有效镁含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04024:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"有机土壤","methodology_zh":"有效镁含量"},{"_id":"6a82e748884ede9a1b2c40e3","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(10,0 – 200,0) mg/100g K2O"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (10,0 – 200,0) mg/100g K2O\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość potasu przyswajalnego\nZakres (10,0 – 200,0) mg/100g K2O\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997 Gleba organiczna Zawartosc potasu przyswajalnego\nZakres (10,0 – 200,0) mg/100g K2O\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(10,0 – 200,0) mg/100g K2O"}],"search_en":"Organic soil Available potassium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04024:1997","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10,0 – 200,0) mg/100g K2O"}],"search_zh":"有机土壤 速效钾含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04024:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"有机土壤","methodology_zh":"速效钾含量"},{"_id":"6a82e748884ede9a1b2c40e4","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(10,0 – 200) mg/100g K2O"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (10,0 – 200) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04024:1997 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04024:1997","PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość potasu przyswajalnego\nZakres (10,0 – 200) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009 Gleba organiczna Zawartosc potasu przyswajalnego\nZakres (10,0 – 200) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(10,0 – 200) mg/100g K2O"}],"search_en":"Organic soil Available potassium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10,0 – 200) mg/100g K2O"}],"search_zh":"有机土壤 速效钾含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"有机土壤","methodology_zh":"速效钾含量"},{"_id":"6a82e748884ede9a1b2c40e5","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(10,0 – 200) mg/100g"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (10,0 – 200) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04024:1997 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04024:1997","PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość magnezu przyswajalnego\nZakres (10,0 – 200) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009 Gleba organiczna Zawartosc magnezu przyswajalnego\nZakres (10,0 – 200) mg/100g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(10,0 – 200) mg/100g"}],"search_en":"Organic soil Available magnesium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10,0 – 200) mg/100g"}],"search_zh":"有机土壤 有效镁含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"有机土壤","methodology_zh":"有效镁含量"},{"_id":"6a82e748884ede9a1b2c40e6","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10 Osady sciekowe, Odpady O) kod: 19 08 05; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10","categories":["environment","water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10"},{"_id":"6a82e748884ede9a1b2c40e7","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PB-13 edycja 3 z dnia 07.04.2022 r.","norm_bases":["PB-13 edycja 3 z dnia 07.04.2022 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Pobieranie próbek do badań mikrobiologicznych PB-13 edycja 3 z dnia 07.04.2022 r. Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Pobieranie probek do badan mikrobiologicznych PB-13 edycja 3 z dnia 07.04.2022 r.","categories":["environment","water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Sampling for microbiological testing PB-13 edycja 3 z dnia 07.04.2022 r.","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PB-13 edycja 3 z dnia 07.04.2022 r."},{"_id":"6a82e748884ede9a1b2c40e8","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(1,0 – 2000) mg/kg"},{"name":"Cd","range":"(0,10 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 1000) mg/kg"},{"name":"Zn","range":"(5,0 – 9000) mg/kg"},{"name":"Cu","range":"(2,5 – 2500) mg/kg"},{"name":"Cr","range":"(2,5 – 4000) mg/kg"},{"name":"Hg","range":"(0,050 – 25,0) mg/kg"},{"name":"Ca","range":"(1,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"},{"name":"K","range":"(0,10 – 2,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (1,0 – 2000) mg/kg\nCd (0,10 – 50,0) mg/kg\nNi (2,5 – 1000) mg/kg\nZn (5,0 – 9000) mg/kg\nCu (2,5 – 2500) mg/kg\nCr (2,5 – 4000) mg/kg\nHg (0,050 – 25,0) mg/kg\nCa (1,0 – 50) %\nMg (0,20 – 5,0) %\nK (0,10 – 2,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","norm_bases":["PN-EN 16174:2012","PN-EN ISO 22036:2024-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość metali\nZakres:\nPb (1,0 – 2000) mg/kg\nCd (0,10 – 50,0) mg/kg\nNi (2,5 – 1000) mg/kg\nZn (5,0 – 9000) mg/kg\nCu (2,5 – 2500) mg/kg\nCr (2,5 – 4000) mg/kg\nHg (0,050 – 25,0) mg/kg\nCa (1,0 – 50) %\nMg (0,20 – 5,0) %\nK (0,10 – 2,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03, 19 08 02; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc metali\nZakres:\nPb (1,0 – 2000) mg/kg\nCd (0,10 – 50,0) mg/kg\nNi (2,5 – 1000) mg/kg\nZn (5,0 – 9000) mg/kg\nCu (2,5 – 2500) mg/kg\nCr (2,5 – 4000) mg/kg\nHg (0,050 – 25,0) mg/kg\nCa (1,0 – 50) %\nMg (0,20 – 5,0) %\nK (0,10 – 2,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","categories":["environment","water","materials"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(1,0 – 2000) mg/kg"},{"name":"Cd","range":"(0,10 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 1000) mg/kg"},{"name":"Zn","range":"(5,0 – 9000) mg/kg"},{"name":"Cu","range":"(2,5 – 2500) mg/kg"},{"name":"Cr","range":"(2,5 – 4000) mg/kg"},{"name":"Hg","range":"(0,050 – 25,0) mg/kg"},{"name":"Ca","range":"(1,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"},{"name":"K","range":"(0,10 – 2,0) %"}],"search_en":"Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Cd Ni Zn Cu Cr Hg Ca Mg K PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"Pb","range":"(1,0 – 2000) mg/kg"},{"name":"Cd","range":"(0,10 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 1000) mg/kg"},{"name":"Zn","range":"(5,0 – 9000) mg/kg"},{"name":"Cu","range":"(2,5 – 2500) mg/kg"},{"name":"Cr","range":"(2,5 – 4000) mg/kg"},{"name":"Hg","range":"(0,050 – 25,0) mg/kg"},{"name":"Ca","range":"(1,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"},{"name":"K","range":"(0,10 – 2,0) %"}],"search_zh":"金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） Pb Cd Ni Zn Cu Cr Ca Mg K PN-EN 16174:2012 | PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量"},{"_id":"6a82e748884ede9a1b2c40e9","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna","reference":"PN-ISO 12176:2004","norm_bases":["PN-ISO 12176:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-ISO 12176:2004 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-ISO 12176:2004","categories":["environment","water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 13,0"}],"search_en":"pH Potentiometric method Range PN-ISO 12176:2004","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 13,0"}],"search_zh":"pH 值 电位法 范围 PN-ISO 12176:2004","technique_zh":"电位法"},{"_id":"6a82e748884ede9a1b2c40ea","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(1,0 – 1500) mg/kg"},{"name":"Cd","range":"(0,25 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(5,0 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 2000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (1,0 – 1500) mg/kg\nCd (0,25 – 50,0) mg/kg\nNi (2,5 – 500) mg/kg\nZn (5,0 – 5000) mg/kg\nCu (2,5 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A | PN-EN 13346:2002 metoda B","norm_bases":["PN-ISO 8288:2002 metoda A","PN-EN 13346:2002 metoda B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość metali\nZakres:\nPb (1,0 – 1500) mg/kg\nCd (0,25 – 50,0) mg/kg\nNi (2,5 – 500) mg/kg\nZn (5,0 – 5000) mg/kg\nCu (2,5 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A | PN-EN 13346:2002 metoda B Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc metali\nZakres:\nPb (1,0 – 1500) mg/kg\nCd (0,25 – 50,0) mg/kg\nNi (2,5 – 500) mg/kg\nZn (5,0 – 5000) mg/kg\nCu (2,5 – 2000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A | PN-EN 13346:2002 metoda B","categories":["environment","water","materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(1,0 – 1500) mg/kg"},{"name":"Cd","range":"(0,25 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(5,0 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 2000) mg/kg"}],"search_en":"Metal content Flame atomic absorption spectrometry (FAAS) Pb Cd Ni Zn Cu PN-ISO 8288:2002 metoda A | PN-EN 13346:2002 metoda B","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"Pb","range":"(1,0 – 1500) mg/kg"},{"name":"Cd","range":"(0,25 – 50,0) mg/kg"},{"name":"Ni","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(5,0 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 2000) mg/kg"}],"search_zh":"金属含量 火焰原子吸收光谱法（FAAS） Pb Cd Ni Zn Cu PN-ISO 8288:2002 metoda A | PN-EN 13346:2002 metoda B","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"金属含量"},{"_id":"6a82e748884ede9a1b2c40eb","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość chromu","parameters":[{"name":"Zakres","range":"(2,5 – 2500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość chromu\nZakres (2,5 – 2500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 | PN-EN 13346:2002 metoda B","norm_bases":["PN-EN 1233:2000","PN-EN 13346:2002 metoda B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość chromu\nZakres (2,5 – 2500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 | PN-EN 13346:2002 metoda B Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc chromu\nZakres (2,5 – 2500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 | PN-EN 13346:2002 metoda B","categories":["environment","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium content","parameters_en":[{"name":"Range","range":"(2,5 – 2500) mg/kg"}],"search_en":"Chromium content Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000 | PN-EN 13346:2002 metoda B","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"范围","range":"(2,5 – 2500) mg/kg"}],"search_zh":"铬含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000 | PN-EN 13346:2002 metoda B","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"铬含量"},{"_id":"6a82e748884ede9a1b2c40ec","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość metali","parameters":[{"name":"Ca","range":"(2,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nCa (2,0 – 50) %\nMg (0,20 – 5,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | PN-EN 13346:2002 metoda B","norm_bases":["PN-EN ISO 7980:2002","PN-EN 13346:2002 metoda B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość metali\nZakres:\nCa (2,0 – 50) %\nMg (0,20 – 5,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002 metoda B Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc metali\nZakres:\nCa (2,0 – 50) %\nMg (0,20 – 5,0) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002 metoda B","categories":["environment","water","materials"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Ca","range":"(2,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"}],"search_en":"Metal content Flame atomic absorption spectrometry (FAAS) Ca Mg PN-EN ISO 7980:2002 | PN-EN 13346:2002 metoda B","technique_en":"Flame atomic absorption spectrometry (FAAS)","search_zh":"金属含量 火焰原子吸收光谱法（FAAS） Ca Mg PN-EN ISO 7980:2002 | PN-EN 13346:2002 metoda B","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"金属含量","parameters_zh":[{"name":"Ca","range":"(2,0 – 50) %"},{"name":"Mg","range":"(0,20 – 5,0) %"}]},{"_id":"6a82e748884ede9a1b2c40ed","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,050 – 15,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,050 – 15,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB-08 edycja 3 z dnia 25.01.2021 r. | PN-EN 13346:2002 metoda B","norm_bases":["PB-08 edycja 3 z dnia 25.01.2021 r.","PN-EN 13346:2002 metoda B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość rtęci\nZakres (0,050 – 15,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-08 edycja 3 z dnia 25.01.2021 r. | PN-EN 13346:2002 metoda B Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc rteci\nZakres (0,050 – 15,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-08 edycja 3 z dnia 25.01.2021 r. | PN-EN 13346:2002 metoda B","categories":["environment","water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,050 – 15,0) mg/kg"}],"search_en":"Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PB-08 edycja 3 z dnia 25.01.2021 r. | PN-EN 13346:2002 metoda B","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,050 – 15,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PB-08 edycja 3 z dnia 25.01.2021 r. | PN-EN 13346:2002 metoda B","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a82e748884ede9a1b2c40ee","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 4,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,50 – 4,0) %\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8 | PN-EN 13346:2002 p. 8.4","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8","PN-EN 13346:2002 p. 8.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość fosforu ogólnego\nZakres (0,50 – 4,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8 | PN-EN 13346:2002 p. 8.4 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc fosforu ogolnego\nZakres (0,50 – 4,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8 | PN-EN 13346:2002 p. 8.4","categories":["environment","water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,50 – 4,0) %"}],"search_en":"Total phosphorus content Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8 | PN-EN 13346:2002 p. 8.4","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,50 – 4,0) %"}],"search_zh":"总磷含量 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 p. 8 | PN-EN 13346:2002 p. 8.4","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a82e748884ede9a1b2c40ef","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(6,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["environment","water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(6,0 – 99,9) %"}],"search_en":"Dry matter content Gravimetric method Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(6,0 – 99,9) %"}],"search_zh":"干物质含量 重量法 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a82e748884ede9a1b2c40f0","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Straty przy prażeniu","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Straty przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Straty przy prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment","water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Loss on ignition Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量"},{"_id":"6a82e748884ede9a1b2c40f1","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment","water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a82e748884ede9a1b2c40f2","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 2,50) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 – 2,50) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość azotu amonowego\nZakres (0,10 – 2,50) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc azotu amonowego\nZakres (0,10 – 2,50) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["environment","water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 2,50) %"}],"search_en":"Ammonium nitrogen content Titrimetric method Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 2,50) %"}],"search_zh":"氨氮含量 滴定法 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a82e748884ede9a1b2c40f3","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Ni","range":"(0,10 – 5,0) mg/l"},{"name":"Zn","range":"(0,10 – 50,0) mg/l"},{"name":"Cu","range":"(0,050 – 10,0) mg/l"},{"name":"Pb","range":"(0,10 – 10,0) mg/l"},{"name":"Cd","range":"(0,050 – 1,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nNi (0,10 – 5,0) mg/l\nZn (0,10 – 50,0) mg/l\nCu (0,050 – 10,0) mg/l\nPb (0,10 – 10,0) mg/l\nCd (0,050 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nNi (0,10 – 5,0) mg/l\nZn (0,10 – 50,0) mg/l\nCu (0,050 – 10,0) mg/l\nPb (0,10 – 10,0) mg/l\nCd (0,050 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, scieki Stezenie metali\nZakres:\nNi (0,10 – 5,0) mg/l\nZn (0,10 – 50,0) mg/l\nCu (0,050 – 10,0) mg/l\nPb (0,10 – 10,0) mg/l\nCd (0,050 – 1,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Ni","range":"(0,10 – 5,0) mg/l"},{"name":"Zn","range":"(0,10 – 50,0) mg/l"},{"name":"Cu","range":"(0,050 – 10,0) mg/l"},{"name":"Pb","range":"(0,10 – 10,0) mg/l"},{"name":"Cd","range":"(0,050 – 1,0) mg/l"}],"search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Ni Zn Cu Pb Cd PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ni","range":"(0,10 – 5,0) mg/l"},{"name":"Zn","range":"(0,10 – 50,0) mg/l"},{"name":"Cu","range":"(0,050 – 10,0) mg/l"},{"name":"Pb","range":"(0,10 – 10,0) mg/l"},{"name":"Cd","range":"(0,050 – 1,0) mg/l"}],"search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） Ni Zn Cu Pb Cd PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40f4","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(0,50 – 50,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (0,50 – 50,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 p. 3","norm_bases":["PN-EN 1233:2000 p. 3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu\nZakres (0,50 – 50,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p. 3 Woda, scieki Stezenie chromu\nZakres (0,50 – 50,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p. 3","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium concentration","parameters_en":[{"name":"Range","range":"(0,50 – 50,0) mg/l"}],"search_en":"Water, wastewater Chromium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000 p. 3","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 50,0) mg/l"}],"search_zh":"水、废水 铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000 p. 3","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"铬浓度"},{"_id":"6a82e748884ede9a1b2c40f5","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(6,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(6,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(6,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a82e748884ede9a1b2c40f6","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (5,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (5,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2500) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2500) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40f7","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012","norm_bases":["PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 40,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 40,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2012","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40f8","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 50,0) mg/l N-NO3"},{"name":"Zakres","range":"(0,44 – 221) mg/l NO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 50,0) mg/l N-NO3\nZakres (0,44 – 221) mg/l NO3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 50,0) mg/l N-NO3\nZakres (0,44 – 221) mg/l NO3\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,10 – 50,0) mg/l N-NO3\nZakres (0,44 – 221) mg/l NO3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50,0) mg/l N-NO3"},{"name":"Range","range":"(0,44 – 221) mg/l NO3"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50,0) mg/l N-NO3"},{"name":"范围","range":"(0,44 – 221) mg/l NO3"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40f9","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l N-NO2"},{"name":"Zakres","range":"(0,033 – 32,8) mg/l NO2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l N-NO2\nZakres (0,033 – 32,8) mg/l NO2\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l N-NO2\nZakres (0,033 – 32,8) mg/l NO2\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l N-NO2\nZakres (0,033 – 32,8) mg/l NO2\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l N-NO2"},{"name":"Range","range":"(0,033 – 32,8) mg/l NO2"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l N-NO2"},{"name":"范围","range":"(0,033 – 32,8) mg/l NO2"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40fa","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,00 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,00 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (2,00 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (2,00 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,00 – 500) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 500) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40fb","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40fc","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c40fd","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-12 edycja 2 z dnia 25.01.2021 r. przy użyciu testów kuwetowych Hach Lange LCK 323","norm_bases":["PB-12 edycja 2 z dnia 25.01.2021 r. przy użyciu testów kuwetowych Hach Lange LCK 323"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fluorków\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PB-12 edycja 2 z dnia 25.01.2021 r. przy użyciu testów kuwetowych Hach Lange LCK 323 Woda, scieki Stezenie fluorkow\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PB-12 edycja 2 z dnia 25.01.2021 r. przy uzyciu testow kuwetowych Hach Lange LCK 323","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 25,0) mg/l"}],"search_en":"Water, wastewater Fluoride concentration Spectrophotometric method Range PB-12 edycja 2 z dnia 25.01.2021 r. przy użyciu testów kuwetowych Hach Lange LCK 323","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 25,0) mg/l"}],"search_zh":"水、废水 氟化物浓度 分光光度法 范围 PB-12 edycja 2 z dnia 25.01.2021 r. przy użyciu testów kuwetowych Hach Lange LCK 323","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"氟化物浓度"},{"_id":"6a82e748884ede9a1b2c40fe","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604-08","norm_bases":["PN-77/C-04604-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604-08 Woda, scieki Stezenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604-08","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604-08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水、废水 六价铬浓度 分光光度法 范围 PN-77/C-04604-08","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a82e748884ede9a1b2c40ff","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, scieki Stezenie zelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Water, wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、废水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4100","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l CaCO3"}],"search_en":"Water, wastewater Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l CaCO3"}],"search_zh":"水、废水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4101","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3,0 – 4000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 4000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 4000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 4000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3,0 – 4000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 4000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82e748884ede9a1b2c4102","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82e748884ede9a1b2c4103","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4104","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a82e748884ede9a1b2c4105","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a82e748884ede9a1b2c4106","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 500) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 500) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4107","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4108","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru wolnego i ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 4,50) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego i ogólnego\nZakres (0,05 – 4,50) mg/l\nMetoda kolorymetryczna","reference":"PB-15 edycja 4 z dnia 13.02.2026 r. przy użyciu testów kuwetowych Merck 1.00599.0001","norm_bases":["PB-15 edycja 4 z dnia 13.02.2026 r. przy użyciu testów kuwetowych Merck 1.00599.0001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru wolnego i ogólnego\nZakres (0,05 – 4,50) mg/l\nMetoda kolorymetryczna PB-15 edycja 4 z dnia 13.02.2026 r. przy użyciu testów kuwetowych Merck 1.00599.0001 Woda, scieki Stezenie chloru wolnego i ogolnego\nZakres (0,05 – 4,50) mg/l\nMetoda kolorymetryczna PB-15 edycja 4 z dnia 13.02.2026 r. przy uzyciu testow kuwetowych Merck 1.00599.0001","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 4,50) mg/l"}],"search_en":"Water, wastewater Free and total chlorine concentration Colorimetric method Range PB-15 edycja 4 z dnia 13.02.2026 r. przy użyciu testów kuwetowych Merck 1.00599.0001","technique_en":"Colorimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 4,50) mg/l"}],"search_zh":"水、废水 游离氯与总氯浓度 比色法 范围 PB-15 edycja 4 z dnia 13.02.2026 r. przy użyciu testów kuwetowych Merck 1.00599.0001","technique_zh":"比色法","test_object_zh":"水、废水","methodology_zh":"游离氯与总氯浓度"},{"_id":"6a82e748884ede9a1b2c4109","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesina łatwoopadająca","parameters":[{"name":"Zakres","range":"(0,5 – 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesina łatwoopadająca\nZakres (0,5 – 100) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesina łatwoopadająca\nZakres (0,5 – 100) ml/l\nMetoda objętościowa PN-72/C-04559/03 Woda, scieki Zawiesina latwoopadajaca\nZakres (0,5 – 100) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,5 – 100) ml/l"}],"search_en":"Water, wastewater Settleable solids Volumetric method Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 100) ml/l"}],"search_zh":"水、废水 容量法 范围 PN-72/C-04559/03","test_object_zh":"水、废水","technique_zh":"容量法"},{"_id":"6a82e748884ede9a1b2c410a","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 6000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 6000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (100 – 6000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 6000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 6000) µS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 6000) µS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c410b","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 1,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-04 edycja 2 z dnia 25.01.2021 r.","norm_bases":["PB-04 edycja 2 z dnia 25.01.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie manganu\nZakres (0,010 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04 edycja 2 z dnia 25.01.2021 r. Woda, scieki Stezenie manganu\nZakres (0,010 – 1,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04 edycja 2 z dnia 25.01.2021 r.","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,0) mg/l"}],"search_en":"Water, wastewater Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PB-04 edycja 2 z dnia 25.01.2021 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1,0) mg/l"}],"search_zh":"水、废水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PB-04 edycja 2 z dnia 25.01.2021 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c410c","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Ni","range":"(0,010 – 10,0) mg/l"},{"name":"Zn","range":"(0,010 – 50,0) mg/l"},{"name":"Cu","range":"(0,010 – 10,0) mg/l"},{"name":"Pb","range":"(0,010 – 10,0) mg/l"},{"name":"Cd","range":"(0,010 – 1,0) mg/l"},{"name":"Cr","range":"(0,010 – 50,0) mg/l"},{"name":"Mn","range":"(0,005 – 2,0) mg/l"},{"name":"Ca","range":"(0,25 – 600) mg/l"},{"name":"Al","range":"(0,010 – 50,0) mg/l"},{"name":"Mg","range":"(0,25 – 250) mg/l"},{"name":"Na","range":"(0,25 – 500) mg/l"},{"name":"Sn","range":"(0,010 – 10,0) mg/l"},{"name":"V","range":"(0,010 – 5,00) mg/l"},{"name":"As","range":"(0,010 – 2,0) mg/l"},{"name":"Ti","range":"(0,010 – 2,0) mg/l"},{"name":"Se","range":"(0,050– 2,0) mg/l"},{"name":"Mo","range":"(0,010 – 5,0) mg/l"},{"name":"B","range":"(0,010 – 5,00) mg/l"},{"name":"Be","range":"(0,010 – 2,00) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 2,0) mg/l"},{"name":"Sb","range":"(0,050 – 2,0) mg/l"},{"name":"K","range":"(0,50 – 1000) mg/l"},{"name":"Ag","range":"(0,010 – 2,00) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nNi (0,010 – 10,0) mg/l\nZn (0,010 – 50,0) mg/l\nCu (0,010 – 10,0) mg/l\nPb (0,010 – 10,0) mg/l\nCd (0,010 – 1,0) mg/l\nCr (0,010 – 50,0) mg/l\nMn (0,005 – 2,0) mg/l\nCa (0,25 – 600) mg/l\nAl (0,010 – 50,0) mg/l\nMg (0,25 – 250) mg/l\nNa (0,25 – 500) mg/l\nSn (0,010 – 10,0) mg/l\nV (0,010 – 5,00) mg/l\nAs (0,010 – 2,0) mg/l\nTi (0,010 – 2,0) mg/l\nSe (0,050– 2,0) mg/l\nMo (0,010 – 5,0) mg/l\nB (0,010 – 5,00) mg/l\nBe (0,010 – 2,00) mg/l\nBa (0,010 – 5,0) mg/l\nCo (0,010 – 2,0) mg/l\nSb (0,050 – 2,0) mg/l\nK (0,50 – 1000) mg/l\nAg (0,010 – 2,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nNi (0,010 – 10,0) mg/l\nZn (0,010 – 50,0) mg/l\nCu (0,010 – 10,0) mg/l\nPb (0,010 – 10,0) mg/l\nCd (0,010 – 1,0) mg/l\nCr (0,010 – 50,0) mg/l\nMn (0,005 – 2,0) mg/l\nCa (0,25 – 600) mg/l\nAl (0,010 – 50,0) mg/l\nMg (0,25 – 250) mg/l\nNa (0,25 – 500) mg/l\nSn (0,010 – 10,0) mg/l\nV (0,010 – 5,00) mg/l\nAs (0,010 – 2,0) mg/l\nTi (0,010 – 2,0) mg/l\nSe (0,050– 2,0) mg/l\nMo (0,010 – 5,0) mg/l\nB (0,010 – 5,00) mg/l\nBe (0,010 – 2,00) mg/l\nBa (0,010 – 5,0) mg/l\nCo (0,010 – 2,0) mg/l\nSb (0,050 – 2,0) mg/l\nK (0,50 – 1000) mg/l\nAg (0,010 – 2,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali\nZakres:\nNi (0,010 – 10,0) mg/l\nZn (0,010 – 50,0) mg/l\nCu (0,010 – 10,0) mg/l\nPb (0,010 – 10,0) mg/l\nCd (0,010 – 1,0) mg/l\nCr (0,010 – 50,0) mg/l\nMn (0,005 – 2,0) mg/l\nCa (0,25 – 600) mg/l\nAl (0,010 – 50,0) mg/l\nMg (0,25 – 250) mg/l\nNa (0,25 – 500) mg/l\nSn (0,010 – 10,0) mg/l\nV (0,010 – 5,00) mg/l\nAs (0,010 – 2,0) mg/l\nTi (0,010 – 2,0) mg/l\nSe (0,050– 2,0) mg/l\nMo (0,010 – 5,0) mg/l\nB (0,010 – 5,00) mg/l\nBe (0,010 – 2,00) mg/l\nBa (0,010 – 5,0) mg/l\nCo (0,010 – 2,0) mg/l\nSb (0,050 – 2,0) mg/l\nK (0,50 – 1000) mg/l\nAg (0,010 – 2,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Ni","range":"(0,010 – 10,0) mg/l"},{"name":"Zn","range":"(0,010 – 50,0) mg/l"},{"name":"Cu","range":"(0,010 – 10,0) mg/l"},{"name":"Pb","range":"(0,010 – 10,0) mg/l"},{"name":"Cd","range":"(0,010 – 1,0) mg/l"},{"name":"Cr","range":"(0,010 – 50,0) mg/l"},{"name":"Mn","range":"(0,005 – 2,0) mg/l"},{"name":"Ca","range":"(0,25 – 600) mg/l"},{"name":"Al","range":"(0,010 – 50,0) mg/l"},{"name":"Mg","range":"(0,25 – 250) mg/l"},{"name":"Na","range":"(0,25 – 500) mg/l"},{"name":"Sn","range":"(0,010 – 10,0) mg/l"},{"name":"V","range":"(0,010 – 5,00) mg/l"},{"name":"As","range":"(0,010 – 2,0) mg/l"},{"name":"Ti","range":"(0,010 – 2,0) mg/l"},{"name":"Se","range":"(0,050– 2,0) mg/l"},{"name":"Mo","range":"(0,010 – 5,0) mg/l"},{"name":"B","range":"(0,010 – 5,00) mg/l"},{"name":"Be","range":"(0,010 – 2,00) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 2,0) mg/l"},{"name":"Sb","range":"(0,050 – 2,0) mg/l"},{"name":"K","range":"(0,50 – 1000) mg/l"},{"name":"Ag","range":"(0,010 – 2,00) mg/l"}],"search_en":"Water, wastewater Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Ni Zn Cu Pb Cd Cr Mn Ca Al Mg Na Sn V As Ti Se Mo B Be Ba Co Sb K Ag PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ni","range":"(0,010 – 10,0) mg/l"},{"name":"Zn","range":"(0,010 – 50,0) mg/l"},{"name":"Cu","range":"(0,010 – 10,0) mg/l"},{"name":"Pb","range":"(0,010 – 10,0) mg/l"},{"name":"Cd","range":"(0,010 – 1,0) mg/l"},{"name":"Cr","range":"(0,010 – 50,0) mg/l"},{"name":"Mn","range":"(0,005 – 2,0) mg/l"},{"name":"Ca","range":"(0,25 – 600) mg/l"},{"name":"Al","range":"(0,010 – 50,0) mg/l"},{"name":"Mg","range":"(0,25 – 250) mg/l"},{"name":"Na","range":"(0,25 – 500) mg/l"},{"name":"Sn","range":"(0,010 – 10,0) mg/l"},{"name":"V","range":"(0,010 – 5,00) mg/l"},{"name":"As","range":"(0,010 – 2,0) mg/l"},{"name":"Ti","range":"(0,010 – 2,0) mg/l"},{"name":"Se","range":"(0,050– 2,0) mg/l"},{"name":"Mo","range":"(0,010 – 5,0) mg/l"},{"name":"B","range":"(0,010 – 5,00) mg/l"},{"name":"Be","range":"(0,010 – 2,00) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 2,0) mg/l"},{"name":"Sb","range":"(0,050 – 2,0) mg/l"},{"name":"K","range":"(0,50 – 1000) mg/l"},{"name":"Ag","range":"(0,010 – 2,00) mg/l"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Ni Zn Cu Pb Cd Cr Mn Ca Al Mg Na Sn V As Ti Se Mo B Be Ba Co Sb K Ag PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c410d","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 2,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,005 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PB-21 edycja 1 z dnia 23.02.2026 r.","norm_bases":["PN-EN ISO 11885:2009","PB-21 edycja 1 z dnia 23.02.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,005 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PB-21 edycja 1 z dnia 23.02.2026 r. Woda, scieki Stezenie rteci\nZakres (0,005 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PB-21 edycja 1 z dnia 23.02.2026 r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,005 – 2,0) mg/l"}],"search_en":"Water, wastewater Mercury concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009 | PB-21 edycja 1 z dnia 23.02.2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 2,0) mg/l"}],"search_zh":"水、废水 汞浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009 | PB-21 edycja 1 z dnia 23.02.2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c410e","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10 – 250 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10 – 250 000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 – 250 000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (10 – 250 000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10 – 250 000) mg/l"}],"search_en":"Water, wastewater Dry residue Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 250 000) mg/l"}],"search_zh":"水、废水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a82e748884ede9a1b2c410f","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie stałych związków rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(10 – 50 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10 – 50 000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10 – 50 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie stalych zwiazkow rozpuszczonych (TDS)\nZakres (10 – 50 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids concentration (TDS)","parameters_en":[{"name":"Range","range":"(10 – 50 000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids concentration (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 50 000) mg/l"}],"search_zh":"水、废水 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a82e748884ede9a1b2c4110","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6, 10.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6, 10.6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6, 10.6 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem p. 7.5, 7.6, 10.6","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6, 10.6","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6, 10.6","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4111","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584 Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 35,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,0 – 35,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a82e748884ede9a1b2c4112","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4113","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584 Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 35,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,0 – 35,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a82e748884ede9a1b2c4114","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Poziom zwierciadła wody","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom zwierciadła wody\nZakres (0,1 – 50,0) m","reference":"PB-17 edycja 1 z dnia 29.01.2025 r.","norm_bases":["PB-17 edycja 1 z dnia 29.01.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Poziom zwierciadła wody\nZakres (0,1 – 50,0) m PB-17 edycja 1 z dnia 29.01.2025 r. Woda Poziom zwierciadla wody\nZakres (0,1 – 50,0) m PB-17 edycja 1 z dnia 29.01.2025 r.","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,1 – 50,0) m"}],"search_en":"Water Range PB-17 edycja 1 z dnia 29.01.2025 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) m"}],"search_zh":"水 范围 PB-17 edycja 1 z dnia 29.01.2025 r.","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4115","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 z wyłączeniem p. 13, 14, 15","norm_bases":["PN-ISO 5667-4:2017-10 z wyłączeniem p. 13, 14, 15"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 z wyłączeniem p. 13, 14, 15 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 z wylaczeniem p. 13, 14, 15","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 z wyłączeniem p. 13, 14, 15","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 z wyłączeniem p. 13, 14, 15","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4116","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584 Woda Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 35,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,0 – 35,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a82e748884ede9a1b2c4117","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4118","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 3,00) mg/l N-NH4"},{"name":"Zakres","range":"(0,06 – 3,86) mg/l NH4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,05 – 3,00) mg/l N-NH4\nZakres (0,06 – 3,86) mg/l NH4\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie jonu amonowego\nZakres:\nZakres (0,05 – 3,00) mg/l N-NH4\nZakres (0,06 – 3,86) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie jonu amonowego\nZakres:\nZakres (0,05 – 3,00) mg/l N-NH4\nZakres (0,06 – 3,86) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 3,00) mg/l N-NH4"},{"name":"Range","range":"(0,06 – 3,86) mg/l NH4"}],"search_en":"Water Ammonium ion concentration Spectrophotometric method Range Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 3,00) mg/l N-NH4"},{"name":"范围","range":"(0,06 – 3,86) mg/l NH4"}],"search_zh":"水 铵离子浓度 分光光度法 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c4119","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 70,0) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 70,0) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C","norm_bases":["PN-EN ISO 7887:2012 metoda C"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5,0 – 70,0) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C Woda Barwa\nZakres (5,0 – 70,0) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5,0 – 70,0) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 – 70,0) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c411a","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 40) NTU"}],"search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 40) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c411b","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki, wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater, rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater, rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a82e748884ede9a1b2c411c","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584 Scieki, wody opadowe i roztopowe Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 35,0) °C"}],"search_en":"Wastewater, rainwater and snowmelt water Temperature Range PN-77/C-04584","test_object_en":"Wastewater, rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(5,0 – 35,0) °C"}],"search_zh":"废水、雨水与融雪水 温度 范围 PN-77/C-04584","methodology_zh":"温度","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a82e748884ede9a1b2c411d","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-20 edycja 1 z dnia 13.02.2026 r.","norm_bases":["PB-20 edycja 1 z dnia 13.02.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PB-20 edycja 1 z dnia 13.02.2026 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PB-20 edycja 1 z dnia 13.02.2026 r.","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing PB-20 edycja 1 z dnia 13.02.2026 r.","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PB-20 edycja 1 z dnia 13.02.2026 r.","test_object_zh":"游泳池水"},{"_id":"6a82e748884ede9a1b2c411e","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda z kąpielisk, woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda z kąpielisk, woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda z kapielisk, woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007"},{"_id":"6a82e748884ede9a1b2c411f","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 2,0) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,005 – 2,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,005 – 2,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 Scieki Stezenie rteci\nZakres (0,005 – 2,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,005 – 2,0) mg/l"}],"search_en":"Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 2,0) mg/l"}],"search_zh":"污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污水"},{"_id":"6a82e748884ede9a1b2c4120","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,150 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,150 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fosforanów\nZakres (0,150 – 100,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012 Woda, woda do spozycia przez ludzi, scieki Stezenie fosforanow\nZakres (0,150 – 100,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,150 – 100,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,150 – 100,0) mg/l"}],"search_zh":"水、生活饮用水、污水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2012","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"磷酸盐浓度"},{"_id":"6a82e748884ede9a1b2c4121","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a82e748884ede9a1b2c4122","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura\nZakres (5,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 35,0) °C"}],"search_en":"Water intended for human consumption Temperature Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,0 – 35,0) °C"}],"search_zh":"生活饮用水 温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a82e748884ede9a1b2c4123","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a82e748884ede9a1b2c4124","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN"},{"_id":"6a82e748884ede9a1b2c4125","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a82e748884ede9a1b2c4126","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a82e748884ede9a1b2c4127","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii z grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"大肠菌群计数"},{"_id":"6a82e748884ede9a1b2c4128","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a82e748884ede9a1b2c4129","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a82e748884ede9a1b2c412a","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water, water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36°C 微生物总数"},{"_id":"6a82e748884ede9a1b2c412b","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 800) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna","reference":"PB-19 edycja 1 z dnia 13.02.2026 r.","norm_bases":["PB-19 edycja 1 z dnia 13.02.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna PB-19 edycja 1 z dnia 13.02.2026 r. Woda, woda do spozycia przez ludzi Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna PB-19 edycja 1 z dnia 13.02.2026 r.","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(200 – 800) mV"}],"search_en":"Water, water intended for human consumption Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-19 edycja 1 z dnia 13.02.2026 r.","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(200 – 800) mV"}],"search_zh":"水、生活饮用水 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 PB-19 edycja 1 z dnia 13.02.2026 r.","technique_zh":"电位法","test_object_zh":"水、生活饮用水","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a82e748884ede9a1b2c412c","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a82e748884ede9a1b2c412d","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Obecność bakterii z rodzaju Salmonella w 100 g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-16 edycja 3 z dnia 01.06.2022 r.","norm_bases":["PB-16 edycja 3 z dnia 01.06.2022 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Obecność bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-16 edycja 3 z dnia 01.06.2022 r. Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Obecnosc bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-16 edycja 3 z dnia 01.06.2022 r.","categories":["environment","microbiology","water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method with biochemical and serological confirmation PB-16 edycja 3 z dnia 01.06.2022 r.","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"培养法结合生化与血清学确认 PB-16 edycja 3 z dnia 01.06.2022 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a82e748884ede9a1b2c412e","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.","parameters":[{"name":"Zakres","range":"od 1 jaja/50 g"},{"name":"Zakres","range":"od 1 jaja/kg s.m."}],"technique":"Metoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej","techniques":["Metoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej"],"computed":[],"activity":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres:\nZakres od 1 jaja/50 g\nZakres od 1 jaja/kg s.m.\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres:\nZakres od 1 jaja/50 g\nZakres od 1 jaja/kg s.m.\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej PN-Z-19005:2018-10 Osady sciekowe, Odpady O) kod: 19 08 05, 19 09 03; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres:\nZakres od 1 jaja/50 g\nZakres od 1 jaja/kg s.m.\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej PN-Z-19005:2018-10","categories":["environment","water","food","construction"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"od 1 jaja/50 g"},{"name":"Range","range":"od 1 jaja/kg s.m."}],"search_en":"Isolation, flotation, incubation and microscopic observation method Range Range PN-Z-19005:2018-10","technique_en":"Isolation, flotation, incubation and microscopic observation method","parameters_zh":[{"name":"范围","range":"od 1 jaja/50 g"},{"name":"范围","range":"od 1 jaja/kg s.m."}],"search_zh":"分离、浮选、培养与显微镜观察法 范围 范围 PN-Z-19005:2018-10","technique_zh":"分离、浮选、培养与显微镜观察法"},{"_id":"6a82e748884ede9a1b2c412f","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-03 edycja 5 z dnia 17.04.2023 r.","norm_bases":["PB-03 edycja 5 z dnia 17.04.2023 r."],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek i badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Pobieranie próbek do badań chemicznych i fizycznych PB-03 edycja 5 z dnia 17.04.2023 r. Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Pobieranie probek do badan chemicznych i fizycznych PB-03 edycja 5 z dnia 17.04.2023 r.","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PB-03 edycja 5 z dnia 17.04.2023 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-03 edycja 5 z dnia 17.04.2023 r."},{"_id":"6a82e748884ede9a1b2c4130","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-ISO 12176:2004","norm_bases":["PN-ISO 12176:2004"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek i badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-ISO 12176:2004 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-ISO 12176:2004","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"pH Potentiometric method Range PN-ISO 12176:2004","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"pH 值 电位法 范围 PN-ISO 12176:2004","technique_zh":"电位法"},{"_id":"6a82e748884ede9a1b2c4131","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(6,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek i badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc suchej masy\nZakres (6,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(6,0 – 99,9) %"}],"search_en":"Dry matter content Gravimetric method Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(6,0 – 99,9) %"}],"search_zh":"干物质含量 重量法 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a82e748884ede9a1b2c4132","lab_id":"69ad52a3de79e566650fb806","country":"PL","accr_number":"AB 1539","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Straty przy prażeniu","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_address":null,"regulatory_area":"Pobieranie próbek i badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Straty przy prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Straty przy prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Loss on ignition Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量"}],"has_pdf":true}