{"lab":{"_id":"69ad52a3de79e566650fb7f8","accr_number":"AB 1527","country":"PL","accr_body":"PCA","address":"ul. Kazimierza Drewnowskiego 2B, 61-248 Poznań","categories":["construction","water"],"city":"Poznań","imported_at":"2026-03-08T10:42:43.265Z","methods_count":58,"name":"BARG ZACHÓD Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1527.pdf"],"scope_summary":"","search_text":"barg zachód sp. z o.o. ul. kazimierza drewnowskiego 2b, 61-248 poznań construction other materials water electronics","status":"active","updated_at":"2026-03-08T14:50:40.533Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:01:24.400Z","email_confidence":"high","email_mx":true,"email_source":"https://barg.pl/en/contact/laboratory/wielkopolskie/","parse_date":"2026-08-13T08:01:24.400Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych","en":"Mechanical tests and sampling of building products"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów i obiektów budowlanych","en":"Mechanical tests of building products and items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Tests of physical properties ad sampling of building products,materials and items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych","en":"Tests of physical properties of building products"}],"issue":{"no":"17","date":"27.07.2026"},"map_coord":[52.37221,16.97134],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Poznań","address":"ul. Kazimierza Drewnowskiego 2B, 61-248 Poznań","city":"Poznań","postal":"61-248"},{"name":"Laboratorium Sulechów","address":"ul. G. Narutowicza 8, 66-100 Sulechów","city":"Sulechów","postal":"66-100"},{"name":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","address":null,"city":null,"postal":null},{"name":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/101ba72a555db7f5b95b5b0133d3feec/AB%201527.pdf","has_en":true,"category_counts":{"other":39,"construction":18,"water":3},"category_scores":{"other":25.35,"construction":5.4,"water":0.15},"has_zh":true,"lab_locations_zh":[{"name":"Laboratorium Poznań","address":"ul. Kazimierza Drewnowskiego 2B, 61-248 Poznań","city":"Poznań","postal":"61-248"},{"name":"Laboratorium Sulechów","address":"ul. G. Narutowicza 8, 66-100 Sulechów","city":"Sulechów","postal":"66-100"},{"name":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","address":null,"city":null,"postal":null},{"name":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79d40636ba417e41ae12","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a7d79d40636ba417e41ae13","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a7d79d40636ba417e41ae14","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0 - 10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nZakres (0 - 10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air content","parameters_en":[{"name":"Range","range":"(0 - 10) %"}],"search_en":"Fresh concrete Air content Pressure gauge method Range PN-EN 12350-7:2019-08","technique_en":"Pressure gauge method","test_object_en":"Fresh concrete","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"(0 - 10) %"}],"search_zh":"混凝土拌合物 含气量 压力计法 范围 PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物"},{"_id":"6a7d79d40636ba417e41ae15","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Concrete in structures Sampling PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a7d79d40636ba417e41ae16","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.8","norm_bases":["PN-EN 932-1:1999 p. 8.8"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p. 8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p. 8.8","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Aggregates Sampling PN-EN 932-1:1999 p. 8.8","test_object_en":"Aggregates","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999 p. 8.8","test_object_zh":"骨料"},{"_id":"6a7d79d40636ba417e41ae17","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.8","norm_bases":["PN-EN 932-1:1999 p. 8.8"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Pobieranie próbek PN-EN 932-1:1999 p. 8.8 Grunty Pobieranie probek PN-EN 932-1:1999 p. 8.8","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Ground Sampling PN-EN 932-1:1999 p. 8.8","test_object_en":"Ground","methodology_zh":"样品采集","search_zh":"土体 样品采集 PN-EN 932-1:1999 p. 8.8","test_object_zh":"土体"},{"_id":"6a7d79d40636ba417e41ae18","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Stopień zagęszczenia (Id)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (Id)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p. 6","norm_bases":["PN-B-04452:2002 p. 6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Stopień zagęszczenia (Id)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p. 6 Grunty Stopien zageszczenia (Id)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p. 6","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density index (Id)","search_en":"Ground Density index (Id) Light probe with conical tip method PN-B-04452:2002 p. 6","technique_en":"Light probe with conical tip method","test_object_en":"Ground","search_zh":"土体 密实度指数（Id） 轻型圆锥头触探仪法 PN-B-04452:2002 p. 6","test_object_zh":"土体","methodology_zh":"密实度指数（Id）","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a7d79d40636ba417e41ae19","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Podłoże","methodology":"Moduł odkształcenia","parameters":[],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Moduł odkształcenia\nMetoda obciążeń płytą VSS PN-S 02205:1998 Podloze Modul odksztalcenia\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Deformation modulus","search_en":"Growing medium Deformation modulus VSS plate loading method PN-S 02205:1998","technique_en":"VSS plate loading method","test_object_en":"Growing medium","search_zh":"栽培基质 变形模量 VSS 平板荷载法 PN-S 02205:1998","test_object_zh":"栽培基质","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a7d79d40636ba417e41ae1a","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Podłoże","methodology":"Dynamiczny moduł odkształcenia","parameters":[{"name":"Zakres","range":"(15-70) MN/m2"}],"technique":"Metoda lekką płytą dynamiczną","techniques":["Metoda lekką płytą dynamiczną"],"computed":[],"activity":"Dynamiczny moduł odkształcenia\nZakres (15-70) MN/m2\nMetoda lekką płytą dynamiczną","reference":"PO-PD/PQ7.2","norm_bases":["PO-PD/PQ7.2"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Dynamiczny moduł odkształcenia\nZakres (15-70) MN/m2\nMetoda lekką płytą dynamiczną PO-PD/PQ7.2 Podloze Dynamiczny modul odksztalcenia\nZakres (15-70) MN/m2\nMetoda lekka plyta dynamiczna PO-PD/PQ7.2","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dynamic deformation modulus","parameters_en":[{"name":"Range","range":"(15-70) MN/m2"}],"search_en":"Growing medium Dynamic deformation modulus Light dynamic plate method Range PO-PD/PQ7.2","technique_en":"Light dynamic plate method","test_object_en":"Growing medium","parameters_zh":[{"name":"范围","range":"(15-70) MN/m2"}],"search_zh":"栽培基质 动态变形模量 范围 PO-PD/PQ7.2","test_object_zh":"栽培基质","methodology_zh":"动态变形模量"},{"_id":"6a7d79d40636ba417e41ae1b","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Podłoże","methodology":"Stopień zagęszczenia (Id)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (Id)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p. 6","norm_bases":["PN-B-04452:2002 p. 6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Stopień zagęszczenia (Id)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p. 6 Podloze Stopien zageszczenia (Id)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p. 6","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density index (Id)","search_en":"Growing medium Density index (Id) Light probe with conical tip method PN-B-04452:2002 p. 6","technique_en":"Light probe with conical tip method","test_object_en":"Growing medium","search_zh":"栽培基质 密实度指数（Id） 轻型圆锥头触探仪法 PN-B-04452:2002 p. 6","test_object_zh":"栽培基质","methodology_zh":"密实度指数（Id）","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a7d79d40636ba417e41ae1c","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres","range":"(0,02-0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres (0,02-0,45) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres (0,02-0,45) MPa\nMetoda obciążeń płytą VSS PN-S 02205:1998 Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres (0,02-0,45) MPa\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Deformation modulus","parameters_en":[{"name":"Range","range":"(0,02-0,45) MPa"}],"search_en":"Pavement structural layers Deformation modulus VSS plate loading method Range PN-S 02205:1998","technique_en":"VSS plate loading method","test_object_en":"Pavement structural layers","parameters_zh":[{"name":"范围","range":"(0,02-0,45) MPa"}],"search_zh":"路面结构层 变形模量 VSS 平板荷载法 范围 PN-S 02205:1998","test_object_zh":"路面结构层","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a7d79d40636ba417e41ae1d","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych","methodology":"Wytrzymałość na odrywanie","parameters":[{"name":"Zakres","range":"(0,4 - 10) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"computed":[],"activity":"Wytrzymałość na odrywanie\nZakres (0,4 - 10) kN\nMetoda pull-off","reference":"PN-EN 1542:2000","norm_bases":["PN-EN 1542:2000"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymałość na odrywanie\nZakres (0,4 - 10) kN\nMetoda pull-off PN-EN 1542:2000 Wyroby i systemy do ochrony i napraw konstrukcji betonowych Wytrzymalosc na odrywanie\nZakres (0,4 - 10) kN\nMetoda pull-off PN-EN 1542:2000","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pull-off strength","parameters_en":[{"name":"Range","range":"(0,4 - 10) kN"}],"search_en":"Products and systems for the protection and repair of concrete structures Pull-off strength Pull-off method Range PN-EN 1542:2000","technique_en":"Pull-off method","test_object_en":"Products and systems for the protection and repair of concrete structures","parameters_zh":[{"name":"范围","range":"(0,4 - 10) kN"}],"search_zh":"混凝土结构防护与修复制品与系统 拉拔强度 拉拔法 范围 PN-EN 1542:2000","technique_zh":"拉拔法","test_object_zh":"混凝土结构防护与修复制品与系统","methodology_zh":"拉拔强度"},{"_id":"6a7d79d40636ba417e41ae1e","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 – 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 – 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 – 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(100 – 3000) kN"}],"search_en":"Concrete Compressive strength BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 – 3000) kN"}],"search_zh":"混凝土 抗压强度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae1f","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość, Określenie objętości na podstawie wymiarów próbki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość, Określenie objętości na podstawie wymiarów próbki","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość, Określenie objętości na podstawie wymiarów próbki PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc, Okreslenie objetosci na podstawie wymiarow probki PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Density, Determination of volume from the sample dimensions","search_en":"Concrete Density, Determination of volume from the sample dimensions BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_en":"Concrete","search_zh":"混凝土 密度，依据试样尺寸确定体积 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"密度，依据试样尺寸确定体积"},{"_id":"6a7d79d40636ba417e41ae20","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(10 – 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (10 – 100) kN","reference":"PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2019-08"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres (10 – 100) kN PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres (10 – 100) kN PN-EN 12390-5:2019-08","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Flexural strength","parameters_en":[{"name":"Range","range":"(10 – 100) kN"}],"search_en":"Concrete Flexural strength BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-EN 12390-5:2019-08","test_object_en":"Concrete","parameters_zh":[{"name":"范围","range":"(10 – 100) kN"}],"search_zh":"混凝土 抗弯强度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae21","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres","range":"(100 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (100 – 3000) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (100 – 3000) kN PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (100 – 3000) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Range","range":"(100 – 3000) kN"}],"search_en":"Concrete Splitting tensile strength BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-EN 12390-6:2024-04","test_object_en":"Concrete","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(100 – 3000) kN"}],"search_zh":"混凝土 劈裂抗拉强度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-EN 12390-6:2024-04","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae22","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete Depth of penetration of water under pressure BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12390-8:2019-08","test_object_en":"Concrete","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12390-8:2019-08","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae23","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Water absorption","search_en":"Concrete Water absorption BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae24","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Water permeability","search_en":"Concrete Water permeability BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"透水性","search_zh":"混凝土 透水性 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae25","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250 | PN-B-06265:2018-10 Zał. N | PN-B-06265:2022-08 Zał. N","norm_bases":["PN-88/B-06250","PN-B-06265:2018-10 Zał. N","PN-B-06265:2022-08 Zał. N"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 | PN-B-06265:2018-10 Zał. N | PN-B-06265:2022-08 Zał. N Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250 | PN-B-06265:2018-10 Zal. N | PN-B-06265:2022-08 Zal. N","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing Ordinary method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-06250 | PN-B-06265:2018-10 Zał. N | PN-B-06265:2022-08 Zał. N","technique_en":"Ordinary method","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-06250 | PN-B-06265:2018-10 Zał. N | PN-B-06265:2022-08 Zał. N","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","technique_zh":"常规法"},{"_id":"6a7d79d40636ba417e41ae26","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(20 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (20 - 3000) kN","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres (20 - 3000) kN PN-EN 12504-1:2019-08 Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres (20 - 3000) kN PN-EN 12504-1:2019-08","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(20 - 3000) kN"}],"search_en":"Concrete in structures Compressive strength BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(20 - 3000) kN"}],"search_zh":"结构中的混凝土 抗压强度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-EN 12504-1:2019-08","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","test_object_zh":"结构中的混凝土"},{"_id":"6a7d79d40636ba417e41ae27","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 90) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 - 90) mm"}],"search_en":"Aggregates Particle size distribution Sieving method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,063 - 90) mm"}],"search_zh":"骨料 粒度分布 筛分法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","technique_zh":"筛分法"},{"_id":"6a7d79d40636ba417e41ae28","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Dust content","search_en":"Aggregates Dust content Sieving method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","search_zh":"骨料 粉尘含量 筛分法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 933-1:2012","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","technique_zh":"筛分法","methodology_zh":"粉尘含量"},{"_id":"6a7d79d40636ba417e41ae29","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Sand equivalent value","search_en":"Aggregates Sand equivalent value BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 933-8+A1:2015-07","test_object_en":"Aggregates","search_zh":"骨料 砂当量 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"砂当量"},{"_id":"6a7d79d40636ba417e41ae2a","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09 | PN-EN 13450:2004 zał. C","norm_bases":["PN-EN 1097-2:2020-09","PN-EN 13450:2004 zał. C"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 | PN-EN 13450:2004 zał. C Kruszywa Odpornosc na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 | PN-EN 13450:2004 zal. C","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Resistance to fragmentation","search_en":"Aggregates Resistance to fragmentation Los Angeles method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 1097-2:2020-09 | PN-EN 13450:2004 zał. C","technique_en":"Los Angeles method","test_object_en":"Aggregates","search_zh":"骨料 抗破碎性 洛杉矶法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 1097-2:2020-09 | PN-EN 13450:2004 zał. C","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a7d79d40636ba417e41ae2b","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nMetoda wagowa","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość wody\nMetoda wagowa PN-EN 1097-5:2008 Kruszywa Zawartosc wody\nMetoda wagowa PN-EN 1097-5:2008","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Water content","search_en":"Aggregates Water content Gravimetric method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 1097-5:2008","technique_en":"Gravimetric method","test_object_en":"Aggregates","methodology_zh":"水分含量","search_zh":"骨料 水分含量 重量法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 1097-5:2008","technique_zh":"重量法","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae2c","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość i nasiąkliwość ziarn","parameters":[],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość i nasiąkliwość ziarn\nMetoda piknometryczna","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość i nasiąkliwość ziarn\nMetoda piknometryczna PN-EN 1097-6:2022-07 Kruszywa Gestosc i nasiakliwosc ziarn\nMetoda piknometryczna PN-EN 1097-6:2022-07","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Particle density and water absorption","search_en":"Aggregates Particle density and water absorption Pycnometric method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 1097-6:2022-07","technique_en":"Pycnometric method","test_object_en":"Aggregates","search_zh":"骨料 比重瓶法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 1097-6:2022-07","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","technique_zh":"比重瓶法"},{"_id":"6a7d79d40636ba417e41ae2d","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność w wodzie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność w wodzie","reference":"PN-EN 1367-1:2007 | PN-EN 13450:2004 zał. F","norm_bases":["PN-EN 1367-1:2007","PN-EN 13450:2004 zał. F"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność w wodzie PN-EN 1367-1:2007 | PN-EN 13450:2004 zał. F Kruszywa Mrozoodpornosc w wodzie PN-EN 1367-1:2007 | PN-EN 13450:2004 zal. F","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Frost resistance in water","search_en":"Aggregates Frost resistance in water BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 1367-1:2007 | PN-EN 13450:2004 zał. F","test_object_en":"Aggregates","search_zh":"骨料 水中抗冻性 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 1367-1:2007 | PN-EN 13450:2004 zał. F","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"水中抗冻性"},{"_id":"6a7d79d40636ba417e41ae2e","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Kalifornijski wskaźnik nośności CBR","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalifornijski wskaźnik nośności CBR","reference":"PN-EN 13286-47:2022-04","norm_bases":["PN-EN 13286-47:2022-04"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Kalifornijski wskaźnik nośności CBR PN-EN 13286-47:2022-04 Kruszywa Kalifornijski wskaznik nosnosci CBR PN-EN 13286-47:2022-04","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"California Bearing Ratio CBR","search_en":"Aggregates California Bearing Ratio CBR BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 13286-47:2022-04","test_object_en":"Aggregates","search_zh":"骨料 加州承载比 CBR BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 13286-47:2022-04","test_object_zh":"骨料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"加州承载比 CBR"},{"_id":"6a7d79d40636ba417e41ae2f","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa – zawartość frakcji","parameters":[{"name":"Zakres","range":"(0,063 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1 Grunty Analiza sitowa – zawartosc frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Sieve analysis – fraction content","parameters_en":[{"name":"Range","range":"(0,063 - 40) mm"}],"search_en":"Ground Sieve analysis – fraction content BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-88/B-04481 p.4.1","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,063 - 40) mm"}],"search_zh":"土体 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-88/B-04481 p.4.1","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae30","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji < 0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji < 0,063 mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji < 0,063 mm PN-88/B-04481 p.4.1 Grunty Zawartosc frakcji < 0,063 mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Content of the < 0,063 mm fraction","search_en":"Ground Content of the < 0,063 mm fraction BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-04481 p.4.1","test_object_en":"Ground","search_zh":"土体 < 0,063 mm 组分含量 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-04481 p.4.1","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"< 0,063 mm 组分含量"},{"_id":"6a7d79d40636ba417e41ae31","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora (metoda I i II)","techniques":["Metoda Proctora (metoda I i II)"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II)","reference":"PN-88/B-04481 p.8","norm_bases":["PN-88/B-04481 p.8"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8 Grunty Wilgotnosc optymalna, Maksymalna gestosc objetosciowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Ground Optimum moisture content, Maximum dry density of the soil skeleton Proctor method (method I and II) BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-04481 p.8","technique_en":"Proctor method (method I and II)","test_object_en":"Ground","search_zh":"土体 最佳含水率、土骨架最大干密度 普氏击实法（方法 I 与 II） BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-04481 p.8","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"最佳含水率、土骨架最大干密度","technique_zh":"普氏击实法（方法 I 与 II）"},{"_id":"6a7d79d40636ba417e41ae32","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Kapilarność bierna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kapilarność bierna","reference":"PN-60/B-04493","norm_bases":["PN-60/B-04493"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Kapilarność bierna PN-60/B-04493 Grunty Kapilarnosc bierna PN-60/B-04493","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Passive capillarity","search_en":"Ground Passive capillarity BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-60/B-04493","test_object_en":"Ground","search_zh":"土体 被动毛细吸水性 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-60/B-04493","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"被动毛细吸水性"},{"_id":"6a7d79d40636ba417e41ae33","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik nośności gruntu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności gruntu","reference":"PN-S-02205:1998","norm_bases":["PN-S-02205:1998"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik nośności gruntu PN-S-02205:1998 Grunty Wskaznik nosnosci gruntu PN-S-02205:1998","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Soil bearing ratio","search_en":"Ground Soil bearing ratio BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-S-02205:1998","test_object_en":"Ground","search_zh":"土体 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-S-02205:1998","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）"},{"_id":"6a7d79d40636ba417e41ae34","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4 Grunty Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Degree of compaction index (ls)","search_en":"Ground Degree of compaction index (ls) Driven cylinder method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Ground","search_zh":"土体 压实指数（ls） 压入圆筒法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"},{"_id":"6a7d79d40636ba417e41ae35","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunt stabilizowany cementem","methodology":"Wytrzymałość na ściskanie stabilizacji","parameters":[{"name":"Zakres","range":"(1-250) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie stabilizacji\nZakres (1-250) kN","reference":"PN-S 96012:1997","norm_bases":["PN-S 96012:1997"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunt stabilizowany cementem Wytrzymałość na ściskanie stabilizacji\nZakres (1-250) kN PN-S 96012:1997 Grunt stabilizowany cementem Wytrzymalosc na sciskanie stabilizacji\nZakres (1-250) kN PN-S 96012:1997","categories":["construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Compressive strength of the stabilised mixture","parameters_en":[{"name":"Range","range":"(1-250) kN"}],"search_en":"Cement-stabilized soil Compressive strength of the stabilised mixture BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) Range PN-S 96012:1997","test_object_en":"Cement-stabilized soil","parameters_zh":[{"name":"范围","range":"(1-250) kN"}],"search_zh":"水泥稳定土 稳定土抗压强度 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） 范围 PN-S 96012:1997","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","test_object_zh":"水泥稳定土","methodology_zh":"稳定土抗压强度"},{"_id":"6a7d79d40636ba417e41ae36","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Podłoże","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4 Podloze Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Degree of compaction index (ls)","search_en":"Growing medium Degree of compaction index (ls) Driven cylinder method BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Growing medium","search_zh":"栽培基质 压实指数（ls） 压入圆筒法 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","test_object_zh":"栽培基质","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"},{"_id":"6a7d79d40636ba417e41ae37","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanki mineralno - asfaltowe","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego","reference":"PN-EN 12697-1:2020-08","norm_bases":["PN-EN 12697-1:2020-08"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno - asfaltowe Zawartość lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08 Mieszanki mineralno - asfaltowe Zawartosc lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Soluble binder content","search_en":"Bituminous mixtures Soluble binder content BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-1:2020-08","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 可溶性胶结料含量 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-1:2020-08","test_object_zh":"沥青混合料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"可溶性胶结料含量"},{"_id":"6a7d79d40636ba417e41ae38","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanki mineralno - asfaltowe","methodology":"Uziarnienie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uziarnienie","reference":"PN-EN 12697-2:2025-06","norm_bases":["PN-EN 12697-2:2025-06"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno - asfaltowe Uziarnienie PN-EN 12697-2:2025-06 Mieszanki mineralno - asfaltowe Uziarnienie PN-EN 12697-2:2025-06","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Grading","search_en":"Bituminous mixtures Grading BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-2:2025-06","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 级配 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-2:2025-06","test_object_zh":"沥青混合料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"级配"},{"_id":"6a7d79d40636ba417e41ae39","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanki mineralno - asfaltowe","methodology":"Gęstość w wodzie","parameters":[],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Gęstość w wodzie\nMetoda A","reference":"PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2019-01"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno - asfaltowe Gęstość w wodzie\nMetoda A PN-EN 12697-5:2019-01 Mieszanki mineralno - asfaltowe Gestosc w wodzie\nMetoda A PN-EN 12697-5:2019-01","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Density in water","search_en":"Bituminous mixtures Density in water Method A BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-5:2019-01","technique_en":"Method A","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 水中密度 方法 A BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-5:2019-01","test_object_zh":"沥青混合料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"水中密度","technique_zh":"方法 A"},{"_id":"6a7d79d40636ba417e41ae3a","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanki mineralno - asfaltowe","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda B","techniques":["Metoda B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda B","reference":"PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2020-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno - asfaltowe Gęstość objętościowa\nMetoda B PN-EN 12697-6:2020-07 Mieszanki mineralno - asfaltowe Gestosc objetosciowa\nMetoda B PN-EN 12697-6:2020-07","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Bulk density","search_en":"Bituminous mixtures Bulk density Method B BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-6:2020-07","technique_en":"Method B","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 堆积密度 方法 B BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-6:2020-07","test_object_zh":"沥青混合料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"堆积密度","technique_zh":"方法 B"},{"_id":"6a7d79d40636ba417e41ae3b","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Mieszanki mineralno - asfaltowe","methodology":"Zawartość wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2019-01 p.4","norm_bases":["PN-EN 12697-8:2019-01 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno - asfaltowe Zawartość wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2019-01 p.4 Mieszanki mineralno - asfaltowe Zawartosc wolnej przestrzeni (z obliczen) PN-EN 12697-8:2019-01 p.4","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Air void content (calculated)","search_en":"Bituminous mixtures Air void content (calculated) BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-8:2019-01 p.4","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 空隙率（计算值） BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-8:2019-01 p.4","test_object_zh":"沥青混合料","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"空隙率（计算值）"},{"_id":"6a7d79d40636ba417e41ae3c","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego","reference":"PN-EN 12697-1:2020-08 p.B.1.7","norm_bases":["PN-EN 12697-1:2020-08 p.B.1.7"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Zawartość lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08 p.B.1.7 Nawierzchnie drogowe (asfaltowe) Zawartosc lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08 p.B.1.7","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Soluble binder content","search_en":"Road pavements (asphalt) Soluble binder content BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-1:2020-08 p.B.1.7","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","search_zh":"路面（沥青） 可溶性胶结料含量 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-1:2020-08 p.B.1.7","methodology_zh":"可溶性胶结料含量","test_object_zh":"路面（沥青）"},{"_id":"6a7d79d40636ba417e41ae3d","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Uziarnienie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uziarnienie","reference":"PN-EN 12697-2:2025-06","norm_bases":["PN-EN 12697-2:2025-06"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Uziarnienie PN-EN 12697-2:2025-06 Nawierzchnie drogowe (asfaltowe) Uziarnienie PN-EN 12697-2:2025-06","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Grading","search_en":"Road pavements (asphalt) Grading BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-2:2025-06","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"级配","search_zh":"路面（沥青） 级配 BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-2:2025-06","test_object_zh":"路面（沥青）"},{"_id":"6a7d79d40636ba417e41ae3e","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Gęstość w wodzie","parameters":[],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Gęstość w wodzie\nMetoda A","reference":"PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2019-01"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Gęstość w wodzie\nMetoda A PN-EN 12697-5:2019-01 Nawierzchnie drogowe (asfaltowe) Gestosc w wodzie\nMetoda A PN-EN 12697-5:2019-01","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Density in water","search_en":"Road pavements (asphalt) Density in water Method A BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-5:2019-01","technique_en":"Method A","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","search_zh":"路面（沥青） 水中密度 方法 A BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-5:2019-01","methodology_zh":"水中密度","test_object_zh":"路面（沥青）","technique_zh":"方法 A"},{"_id":"6a7d79d40636ba417e41ae3f","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda B","techniques":["Metoda B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda B","reference":"PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2020-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Gęstość objętościowa\nMetoda B PN-EN 12697-6:2020-07 Nawierzchnie drogowe (asfaltowe) Gestosc objetosciowa\nMetoda B PN-EN 12697-6:2020-07","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Bulk density","search_en":"Road pavements (asphalt) Bulk density Method B BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-6:2020-07","technique_en":"Method B","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","methodology_zh":"堆积密度","search_zh":"路面（沥青） 堆积密度 方法 B BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-6:2020-07","test_object_zh":"路面（沥青）","technique_zh":"方法 B"},{"_id":"6a7d79d40636ba417e41ae40","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Zawartość wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2019-01 p.4","norm_bases":["PN-EN 12697-8:2019-01 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Zawartość wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2019-01 p.4 Nawierzchnie drogowe (asfaltowe) Zawartosc wolnej przestrzeni (z obliczen) PN-EN 12697-8:2019-01 p.4","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Air void content (calculated)","search_en":"Road pavements (asphalt) Air void content (calculated) BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 12697-8:2019-01 p.4","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","search_zh":"路面（沥青） 空隙率（计算值） BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 12697-8:2019-01 p.4","methodology_zh":"空隙率（计算值）","test_object_zh":"路面（沥青）"},{"_id":"6a7d79d40636ba417e41ae41","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Wskaźnik zagęszczenia warstwy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik zagęszczenia warstwy (z obliczeń)","reference":"PN-EN 13108-20:2016-07 Zał. C.4","norm_bases":["PN-EN 13108-20:2016-07 Zał. C.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Poznań; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Wskaźnik zagęszczenia warstwy (z obliczeń) PN-EN 13108-20:2016-07 Zał. C.4 Nawierzchnie drogowe (asfaltowe) Wskaznik zageszczenia warstwy (z obliczen) PN-EN 13108-20:2016-07 Zal. C.4","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity)","methodology_en":"Layer compaction index (calculated)","search_en":"Road pavements (asphalt) Layer compaction index (calculated) BARG ZACHÓD Sp. z o.o.; Poznań Laboratory; (stationary technical activity) PN-EN 13108-20:2016-07 Zał. C.4","test_object_en":"Road pavements (asphalt)","lab_section_zh":"BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动）","search_zh":"路面（沥青） BARG ZACHÓD Sp. z o.o.；Poznań 实验室；（固定技术活动） PN-EN 13108-20:2016-07 Zał. C.4","test_object_zh":"路面（沥青）"},{"_id":"6a7d79d40636ba417e41ae42","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 – 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 – 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 – 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(100 – 3000) kN"}],"search_en":"Concrete Compressive strength BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 – 3000) kN"}],"search_zh":"混凝土 抗压强度 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）"},{"_id":"6a7d79d40636ba417e41ae43","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość, Określenie objętości na podstawie wymiarów próbki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość, Określenie objętości na podstawie wymiarów próbki","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość, Określenie objętości na podstawie wymiarów próbki PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc, Okreslenie objetosci na podstawie wymiarow probki PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Density, Determination of volume from the sample dimensions","search_en":"Concrete Density, Determination of volume from the sample dimensions BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_en":"Concrete","search_zh":"混凝土 密度，依据试样尺寸确定体积 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","methodology_zh":"密度，依据试样尺寸确定体积"},{"_id":"6a7d79d40636ba417e41ae44","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Water absorption","search_en":"Concrete Water absorption BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）"},{"_id":"6a7d79d40636ba417e41ae45","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 - 63) mm"}],"search_en":"Aggregates Particle size distribution Sieving method BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,063 - 63) mm"}],"search_zh":"骨料 粒度分布 筛分法 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）"},{"_id":"6a7d79d40636ba417e41ae46","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Dust content","search_en":"Aggregates Dust content Sieving method BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","search_zh":"骨料 粉尘含量 筛分法 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-EN 933-1:2012","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"粉尘含量","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）"},{"_id":"6a7d79d40636ba417e41ae47","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa – zawartość frakcji","parameters":[{"name":"Zakres","range":"(0,063 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1 Grunty Analiza sitowa – zawartosc frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Sieve analysis – fraction content","parameters_en":[{"name":"Range","range":"(0,063 - 40) mm"}],"search_en":"Ground Sieve analysis – fraction content BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) Range PN-88/B-04481 p.4.1","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,063 - 40) mm"}],"search_zh":"土体 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） 范围 PN-88/B-04481 p.4.1","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）"},{"_id":"6a7d79d40636ba417e41ae48","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji < 0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji < 0,063 mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji < 0,063 mm PN-88/B-04481 p.4.1 Grunty Zawartosc frakcji < 0,063 mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Content of the < 0,063 mm fraction","search_en":"Ground Content of the < 0,063 mm fraction BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-88/B-04481 p.4.1","test_object_en":"Ground","search_zh":"土体 < 0,063 mm 组分含量 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-88/B-04481 p.4.1","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","methodology_zh":"< 0,063 mm 组分含量"},{"_id":"6a7d79d40636ba417e41ae49","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora (metoda I i II)","techniques":["Metoda Proctora (metoda I i II)"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II)","reference":"PN-88/B-04481 p.8","norm_bases":["PN-88/B-04481 p.8"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8 Grunty Wilgotnosc optymalna, Maksymalna gestosc objetosciowa szkieletu gruntowego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Ground Optimum moisture content, Maximum dry density of the soil skeleton Proctor method (method I and II) BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-88/B-04481 p.8","technique_en":"Proctor method (method I and II)","test_object_en":"Ground","search_zh":"土体 最佳含水率、土骨架最大干密度 普氏击实法（方法 I 与 II） BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-88/B-04481 p.8","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","methodology_zh":"最佳含水率、土骨架最大干密度","technique_zh":"普氏击实法（方法 I 与 II）"},{"_id":"6a7d79d40636ba417e41ae4a","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4 Grunty Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Degree of compaction index (ls)","search_en":"Ground Degree of compaction index (ls) Driven cylinder method BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Ground","search_zh":"土体 压实指数（ls） 压入圆筒法 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","test_object_zh":"土体","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"},{"_id":"6a7d79d40636ba417e41ae4b","lab_id":"69ad52a3de79e566650fb7f8","country":"PL","accr_number":"AB 1527","accr_body":"PCA","test_object":"Podłoże","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4"],"lab_section":"BARG ZACHÓD Sp. z o.o.; Laboratorium Sulechów; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4 Podloze Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity)","methodology_en":"Degree of compaction index (ls)","search_en":"Growing medium Degree of compaction index (ls) Driven cylinder method BARG ZACHÓD Sp. z o.o.; Laboratory Sulechów; (stationary technical activity) PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","technique_en":"Driven cylinder method","test_object_en":"Growing medium","search_zh":"栽培基质 压实指数（ls） 压入圆筒法 BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动） PN-88/B-04481 p.5.2.6 BN-77/8931-12 p.4","test_object_zh":"栽培基质","lab_section_zh":"BARG ZACHÓD 有限责任公司；苏莱胡夫实验室；（固定场所技术活动）","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"}],"has_pdf":true}