{"lab":{"_id":"69ad52a3de79e566650fb7ec","accr_number":"AB 1520","country":"PL","accr_body":"PCA","address":"LABORATORIUM CHEMICZNE ITPL, Jankowice, ul. Przemysłowa 1, 62-080 Tarnowo Podgórne","categories":["water"],"city":"Tarnowo Podgórne","imported_at":"2026-03-08T10:42:43.265Z","methods_count":16,"name":"IMPERIAL TOBACCO POLSKA S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1520.pdf"],"scope_summary":"","search_text":"imperial tobacco polska s.a. laboratorium chemiczne itpl, jankowice, ul. przemysłowa 1, 62-080 tarnowo podgórne other water metrology","status":"active","updated_at":"2026-03-08T14:50:40.116Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:43:48.146Z","email_confidence":"high","email_mx":true,"email_source":"https://imperial-tobacco.pl/kontakt/","parse_date":"2026-08-17T10:43:48.146Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/24","pl":"Badania chemiczne, wyrobów tytoniowych","en":"Chemical tests of tobacco products"},{"codes":"N/24","pl":"Badania właściwości fizycznych wyrobów tytoniowych","en":"Tests of physical properties of tobacco products"}],"issue":{"no":"12","date":"24.06.2026"},"map_coord":[52.453057,16.647427],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM CHEMICZNE ITPL","address":"Jankowice, ul. Przemysłowa 1","city":"Tarnowo Podgórne","postal":"62-080"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/106ea1f109b81c1b214ecc7b475efc6d/AB%201520.pdf","has_en":true,"category_counts":{"other":14,"water":2},"category_scores":{"other":12.25,"water":0.25},"has_zh":true},"methods":[{"_id":"6a82e5e4884ede9a1b2c3fd1","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zawartość tlenku węgla w fazie gazowej dymu / Carbon Monoxide in vapour phase from the smoke","parameters":[{"name":"Zakres","range":"(0,50 – 15,0) mg/papieros"},{"name":"Scope","range":"(0,50 – 15,0) mg/cigarette"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) / NDIR Method","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","NDIR Method"],"computed":[],"activity":"Zawartość tlenku węgla w fazie gazowej dymu / Carbon Monoxide in vapour phase from the smoke\nZakres:\nZakres (0,50 – 15,0) mg/papieros\nScope (0,50 – 15,0) mg/cigarette\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) / NDIR Method","reference":"ISO 8454:2024-4","norm_bases":["ISO 8454:2024-4"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zawartość tlenku węgla w fazie gazowej dymu / Carbon Monoxide in vapour phase from the smoke\nZakres:\nZakres (0,50 – 15,0) mg/papieros\nScope (0,50 – 15,0) mg/cigarette\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) / NDIR Method ISO 8454:2024-4 Papierosy / Cigarettes Zawartosc tlenku wegla w fazie gazowej dymu / Carbon Monoxide in vapour phase from the smoke\nZakres:\nZakres (0,50 – 15,0) mg/papieros\nScope (0,50 – 15,0) mg/cigarette\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) / NDIR Method ISO 8454:2024-4","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,50 – 15,0) mg/papieros"},{"name":"Scope","range":"(0,50 – 15,0) mg/cigarette"}],"search_en":"Range Scope ISO 8454:2024-4","parameters_zh":[{"name":"范围","range":"(0,50 – 15,0) mg/papieros"},{"name":"范围","range":"(0,50 – 15,0) mg/cigarette"}],"search_zh":"范围 范围 ISO 8454:2024-4"},{"_id":"6a82e5e4884ede9a1b2c3fd2","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zawartość nikotyny w kondensacie dymu / Nicotine in total particular matter from the smoke","parameters":[{"name":"Zakres","range":"(0,030 – 1,40) mg/papieros"},{"name":"Scope","range":"(0,030 – 1,40) mg/cigarette"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC – FID) / GC- FID Method","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC – FID)","GC- FID Method"],"computed":[],"activity":"Zawartość nikotyny w kondensacie dymu / Nicotine in total particular matter from the smoke\nZakres:\nZakres (0,030 – 1,40) mg/papieros\nScope (0,030 – 1,40) mg/cigarette\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC – FID) / GC- FID Method","reference":"ISO 10315:2021-06","norm_bases":["ISO 10315:2021-06"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zawartość nikotyny w kondensacie dymu / Nicotine in total particular matter from the smoke\nZakres:\nZakres (0,030 – 1,40) mg/papieros\nScope (0,030 – 1,40) mg/cigarette\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC – FID) / GC- FID Method ISO 10315:2021-06 Papierosy / Cigarettes Zawartosc nikotyny w kondensacie dymu / Nicotine in total particular matter from the smoke\nZakres:\nZakres (0,030 – 1,40) mg/papieros\nScope (0,030 – 1,40) mg/cigarette\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC – FID) / GC- FID Method ISO 10315:2021-06","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,030 – 1,40) mg/papieros"},{"name":"Scope","range":"(0,030 – 1,40) mg/cigarette"}],"search_en":"Range Scope ISO 10315:2021-06","parameters_zh":[{"name":"范围","range":"(0,030 – 1,40) mg/papieros"},{"name":"范围","range":"(0,030 – 1,40) mg/cigarette"}],"search_zh":"范围 范围 ISO 10315:2021-06"},{"_id":"6a82e5e4884ede9a1b2c3fd3","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zawartość wody w kondensacie dymu / Water in total particular matter from the smoke","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) mg/papieros"},{"name":"Scope","range":"(0,1 – 5,0) mg/cigarette"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC – TCD) / GC- TCD Method","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC – TCD)","GC- TCD Method"],"computed":[],"activity":"Zawartość wody w kondensacie dymu / Water in total particular matter from the smoke\nZakres:\nZakres (0,1 – 5,0) mg/papieros\nScope (0,1 – 5,0) mg/cigarette\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC – TCD) / GC- TCD Method","reference":"ISO 10362-1:2019-07","norm_bases":["ISO 10362-1:2019-07"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zawartość wody w kondensacie dymu / Water in total particular matter from the smoke\nZakres:\nZakres (0,1 – 5,0) mg/papieros\nScope (0,1 – 5,0) mg/cigarette\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC – TCD) / GC- TCD Method ISO 10362-1:2019-07 Papierosy / Cigarettes Zawartosc wody w kondensacie dymu / Water in total particular matter from the smoke\nZakres:\nZakres (0,1 – 5,0) mg/papieros\nScope (0,1 – 5,0) mg/cigarette\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC – TCD) / GC- TCD Method ISO 10362-1:2019-07","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,1 – 5,0) mg/papieros"},{"name":"Scope","range":"(0,1 – 5,0) mg/cigarette"}],"search_en":"Range Scope ISO 10362-1:2019-07","parameters_zh":[{"name":"范围","range":"(0,1 – 5,0) mg/papieros"},{"name":"范围","range":"(0,1 – 5,0) mg/cigarette"}],"search_zh":"范围 范围 ISO 10362-1:2019-07"},{"_id":"6a82e5e4884ede9a1b2c3fd4","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zawartość surowego kondensatu dymu / Total Particulate Matter from the smoke","parameters":[{"name":"Zakres","range":"(0,50 – 20,00) mg/papieros"},{"name":"Scope","range":"(0,50 – 20,00) mg/cigarette"}],"technique":"Metoda wagowa / Gravimetric method","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość surowego kondensatu dymu / Total Particulate Matter from the smoke\nZakres:\nZakres (0,50 – 20,00) mg/papieros\nScope (0,50 – 20,00) mg/cigarette\nMetoda wagowa / Gravimetric method","reference":"ISO 4387:2019-09","norm_bases":["ISO 4387:2019-09"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zawartość surowego kondensatu dymu / Total Particulate Matter from the smoke\nZakres:\nZakres (0,50 – 20,00) mg/papieros\nScope (0,50 – 20,00) mg/cigarette\nMetoda wagowa / Gravimetric method ISO 4387:2019-09 Papierosy / Cigarettes Zawartosc surowego kondensatu dymu / Total Particulate Matter from the smoke\nZakres:\nZakres (0,50 – 20,00) mg/papieros\nScope (0,50 – 20,00) mg/cigarette\nMetoda wagowa / Gravimetric method ISO 4387:2019-09","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,50 – 20,00) mg/papieros"},{"name":"Scope","range":"(0,50 – 20,00) mg/cigarette"}],"search_en":"Range Scope ISO 4387:2019-09","parameters_zh":[{"name":"范围","range":"(0,50 – 20,00) mg/papieros"},{"name":"范围","range":"(0,50 – 20,00) mg/cigarette"}],"search_zh":"范围 范围 ISO 4387:2019-09"},{"_id":"6a82e5e4884ede9a1b2c3fd5","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zawartość substancji smolistych w kondensacie dymu / Nicotine-free dry particulate matter from the smoke","parameters":[],"technique":"Z obliczeń / Calculated","techniques":["Z obliczeń","Calculated"],"computed":[],"activity":"Zawartość substancji smolistych w kondensacie dymu / Nicotine-free dry particulate matter from the smoke\nZ obliczeń / Calculated","reference":"ISO 4387:2019-09","norm_bases":["ISO 4387:2019-09"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zawartość substancji smolistych w kondensacie dymu / Nicotine-free dry particulate matter from the smoke\nZ obliczeń / Calculated ISO 4387:2019-09 Papierosy / Cigarettes Zawartosc substancji smolistych w kondensacie dymu / Nicotine-free dry particulate matter from the smoke\nZ obliczen / Calculated ISO 4387:2019-09","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a82e5e4884ede9a1b2c3fd6","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Zdolność zapłonu papierosów / Ignition propensity of cigarettes","parameters":[{"name":"Zakres","range":"(0,0 – 100,0) %"},{"name":"Scope","range":"(0,0 – 100,0) %"}],"technique":"Metoda spalania w komorze testowej / Combustion method in a test chamber","techniques":["Metoda spalania w komorze testowej","Combustion method in a test chamber"],"computed":[],"activity":"Zdolność zapłonu papierosów / Ignition propensity of cigarettes\nZakres:\nZakres (0,0 – 100,0) %\nScope (0,0 – 100,0) %\nMetoda spalania w komorze testowej / Combustion method in a test chamber","reference":"ISO 12863: 2022-04","norm_bases":["ISO 12863: 2022-04"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Zdolność zapłonu papierosów / Ignition propensity of cigarettes\nZakres:\nZakres (0,0 – 100,0) %\nScope (0,0 – 100,0) %\nMetoda spalania w komorze testowej / Combustion method in a test chamber ISO 12863: 2022-04 Papierosy / Cigarettes Zdolnosc zaplonu papierosow / Ignition propensity of cigarettes\nZakres:\nZakres (0,0 – 100,0) %\nScope (0,0 – 100,0) %\nMetoda spalania w komorze testowej / Combustion method in a test chamber ISO 12863: 2022-04","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0 – 100,0) %"},{"name":"Scope","range":"(0,0 – 100,0) %"}],"search_en":"Range Scope ISO 12863: 2022-04","parameters_zh":[{"name":"范围","range":"(0,0 – 100,0) %"},{"name":"范围","range":"(0,0 – 100,0) %"}],"search_zh":"范围 范围 ISO 12863: 2022-04"},{"_id":"6a82e5e4884ede9a1b2c3fd7","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Masa / Mass","parameters":[{"name":"Zakres","range":"(400 – 1200) mg"},{"name":"Scope","range":"(400 – 1200) mg"}],"technique":"Metoda wagowa / Gravimetric method","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Masa / Mass\nZakres:\nZakres (400 – 1200) mg\nScope (400 – 1200) mg\nMetoda wagowa / Gravimetric method","reference":"TM061, ed. 1 z 30.09.2019","norm_bases":["TM061, ed. 1 z 30.09.2019"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Masa / Mass\nZakres:\nZakres (400 – 1200) mg\nScope (400 – 1200) mg\nMetoda wagowa / Gravimetric method TM061, ed. 1 z 30.09.2019 Papierosy / Cigarettes Masa / Mass\nZakres:\nZakres (400 – 1200) mg\nScope (400 – 1200) mg\nMetoda wagowa / Gravimetric method TM061, ed. 1 z 30.09.2019","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(400 – 1200) mg"},{"name":"Scope","range":"(400 – 1200) mg"}],"search_en":"Mass Range Scope TM061, ed. 1 z 30.09.2019","parameters_zh":[{"name":"范围","range":"(400 – 1200) mg"},{"name":"范围","range":"(400 – 1200) mg"}],"search_zh":"范围 范围 TM061, ed. 1 z 30.09.2019"},{"_id":"6a82e5e4884ede9a1b2c3fd8","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Średnica / Nominal diamater","parameters":[{"name":"Zakres","range":"(5,000 – 8,500) mm"},{"name":"Scope","range":"(5,000 – 8,500) mm"}],"technique":"Metoda pomiaru laserowego / Method using a non-contact optical measuring apparatus","techniques":["Metoda pomiaru laserowego","Method using a non-contact optical measuring apparatus"],"computed":[],"activity":"Średnica / Nominal diamater\nZakres:\nZakres (5,000 – 8,500) mm\nScope (5,000 – 8,500) mm\nMetoda pomiaru laserowego / Method using a non-contact optical measuring apparatus","reference":"ISO 2971:2013-04","norm_bases":["ISO 2971:2013-04"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Średnica / Nominal diamater\nZakres:\nZakres (5,000 – 8,500) mm\nScope (5,000 – 8,500) mm\nMetoda pomiaru laserowego / Method using a non-contact optical measuring apparatus ISO 2971:2013-04 Papierosy / Cigarettes Srednica / Nominal diamater\nZakres:\nZakres (5,000 – 8,500) mm\nScope (5,000 – 8,500) mm\nMetoda pomiaru laserowego / Method using a non-contact optical measuring apparatus ISO 2971:2013-04","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(5,000 – 8,500) mm"},{"name":"Scope","range":"(5,000 – 8,500) mm"}],"search_en":"Range Scope ISO 2971:2013-04","parameters_zh":[{"name":"范围","range":"(5,000 – 8,500) mm"},{"name":"范围","range":"(5,000 – 8,500) mm"}],"search_zh":"范围 范围 ISO 2971:2013-04"},{"_id":"6a82e5e4884ede9a1b2c3fd9","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Wentylacja / Ventilation","parameters":[{"name":"Zakres","range":"(1,5 – 90) %"},{"name":"Scope","range":"(1,5 – 90) %"}],"technique":"Metoda pomiaru podciśnienia / Pressure differential measurement method","techniques":["Metoda pomiaru podciśnienia","Pressure differential measurement method"],"computed":[],"activity":"Wentylacja / Ventilation\nZakres:\nZakres (1,5 – 90) %\nScope (1,5 – 90) %\nMetoda pomiaru podciśnienia / Pressure differential measurement method","reference":"ISO 9512:2019-06","norm_bases":["ISO 9512:2019-06"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Wentylacja / Ventilation\nZakres:\nZakres (1,5 – 90) %\nScope (1,5 – 90) %\nMetoda pomiaru podciśnienia / Pressure differential measurement method ISO 9512:2019-06 Papierosy / Cigarettes Wentylacja / Ventilation\nZakres:\nZakres (1,5 – 90) %\nScope (1,5 – 90) %\nMetoda pomiaru podcisnienia / Pressure differential measurement method ISO 9512:2019-06","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,5 – 90) %"},{"name":"Scope","range":"(1,5 – 90) %"}],"search_en":"Range Scope ISO 9512:2019-06","parameters_zh":[{"name":"范围","range":"(1,5 – 90) %"},{"name":"范围","range":"(1,5 – 90) %"}],"search_zh":"范围 范围 ISO 9512:2019-06"},{"_id":"6a82e5e4884ede9a1b2c3fda","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Oporność otwarta, oporność zamknięta / Pressure Drop (open), Pressure drop (closed)","parameters":[{"name":"Zakres","range":"(30 – 400) mm WG"},{"name":"Scope","range":"(30 – 400) mm WG"}],"technique":"Metoda pomiaru różnicy ciśnienia / Pressure differential measurement method","techniques":["Metoda pomiaru różnicy ciśnienia","Pressure differential measurement method"],"computed":[],"activity":"Oporność otwarta, oporność zamknięta / Pressure Drop (open), Pressure drop (closed)\nZakres:\nZakres (30 – 400) mm WG\nScope (30 – 400) mm WG\nMetoda pomiaru różnicy ciśnienia / Pressure differential measurement method","reference":"ISO 6565:2015-12","norm_bases":["ISO 6565:2015-12"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Oporność otwarta, oporność zamknięta / Pressure Drop (open), Pressure drop (closed)\nZakres:\nZakres (30 – 400) mm WG\nScope (30 – 400) mm WG\nMetoda pomiaru różnicy ciśnienia / Pressure differential measurement method ISO 6565:2015-12 Papierosy / Cigarettes Opornosc otwarta, opornosc zamknieta / Pressure Drop (open), Pressure drop (closed)\nZakres:\nZakres (30 – 400) mm WG\nScope (30 – 400) mm WG\nMetoda pomiaru roznicy cisnienia / Pressure differential measurement method ISO 6565:2015-12","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(30 – 400) mm WG"},{"name":"Scope","range":"(30 – 400) mm WG"}],"search_en":"Range Scope ISO 6565:2015-12","parameters_zh":[{"name":"范围","range":"(30 – 400) mm WG"},{"name":"范围","range":"(30 – 400) mm WG"}],"search_zh":"范围 范围 ISO 6565:2015-12"},{"_id":"6a82e5e4884ede9a1b2c3fdb","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Pomiar ilości zaciągnięć papierosa / Cigarette puff count measurement","parameters":[{"name":"Zakres","range":"(4 – 12) zaciągnięć / papieros"},{"name":"Scope","range":"(4 –12) puffs / cigarette"}],"technique":"Metoda kontrolowanego zaciągu o stałej objętości / Method of controlled constant-volume puffing","techniques":["Metoda kontrolowanego zaciągu o stałej objętości","Method of controlled constant-volume puffing"],"computed":[],"activity":"Pomiar ilości zaciągnięć papierosa / Cigarette puff count measurement\nZakres:\nZakres (4 – 12) zaciągnięć / papieros\nScope (4 –12) puffs / cigarette\nMetoda kontrolowanego zaciągu o stałej objętości / Method of controlled constant-volume puffing","reference":"ISO 4387:2019-09","norm_bases":["ISO 4387:2019-09"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Pomiar ilości zaciągnięć papierosa / Cigarette puff count measurement\nZakres:\nZakres (4 – 12) zaciągnięć / papieros\nScope (4 –12) puffs / cigarette\nMetoda kontrolowanego zaciągu o stałej objętości / Method of controlled constant-volume puffing ISO 4387:2019-09 Papierosy / Cigarettes Pomiar ilosci zaciagniec papierosa / Cigarette puff count measurement\nZakres:\nZakres (4 – 12) zaciagniec / papieros\nScope (4 –12) puffs / cigarette\nMetoda kontrolowanego zaciagu o stalej objetosci / Method of controlled constant-volume puffing ISO 4387:2019-09","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(4 – 12) zaciągnięć / papieros"},{"name":"Scope","range":"(4 –12) puffs / cigarette"}],"search_en":"Range Scope ISO 4387:2019-09","parameters_zh":[{"name":"范围","range":"(4 – 12) zaciągnięć / papieros"},{"name":"范围","range":"(4 –12) puffs / cigarette"}],"search_zh":"范围 范围 ISO 4387:2019-09"},{"_id":"6a82e5e4884ede9a1b2c3fdc","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Papierosy / Cigarettes","methodology":"Pomiar długości papierosa za pomocą urządzenia LML / Determination of cigarette length using an LML device","parameters":[{"name":"Zakres","range":"(12 – 110) mm"},{"name":"Scope","range":"(12 – 110) mm"}],"technique":"Metoda pomiaru długości / Length measurement method","techniques":["Metoda pomiaru długości","Length measurement method"],"computed":[],"activity":"Pomiar długości papierosa za pomocą urządzenia LML / Determination of cigarette length using an LML device\nZakres:\nZakres (12 – 110) mm\nScope (12 – 110) mm\nMetoda pomiaru długości / Length measurement method","reference":"TM059, ed. 1 z 23.09.2022","norm_bases":["TM059, ed. 1 z 23.09.2022"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy / Cigarettes Pomiar długości papierosa za pomocą urządzenia LML / Determination of cigarette length using an LML device\nZakres:\nZakres (12 – 110) mm\nScope (12 – 110) mm\nMetoda pomiaru długości / Length measurement method TM059, ed. 1 z 23.09.2022 Papierosy / Cigarettes Pomiar dlugosci papierosa za pomoca urzadzenia LML / Determination of cigarette length using an LML device\nZakres:\nZakres (12 – 110) mm\nScope (12 – 110) mm\nMetoda pomiaru dlugosci / Length measurement method TM059, ed. 1 z 23.09.2022","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(12 – 110) mm"},{"name":"Scope","range":"(12 – 110) mm"}],"search_en":"Range Scope TM059, ed. 1 z 23.09.2022","parameters_zh":[{"name":"范围","range":"(12 – 110) mm"},{"name":"范围","range":"(12 – 110) mm"}],"search_zh":"范围 范围 TM059, ed. 1 z 23.09.2022"},{"_id":"6a82e5e4884ede9a1b2c3fdd","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Wyroby tytoniowe / Tobacco products","methodology":"Zawartość propylenoglikolu i glicerolu / Content of propylene glycol and glycerol","parameters":[{"name":"Zakres","range":"(0,3 – 5,0) % suchej masy"},{"name":"Scope","range":"((0,3 – 5,0) % dwb"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","HPLC-RID Method"],"computed":[],"activity":"Zawartość propylenoglikolu i glicerolu / Content of propylene glycol and glycerol\nZakres:\nZakres (0,3 – 5,0) % suchej masy\nScope ((0,3 – 5,0) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method","reference":"DIN 10372:2001-01","norm_bases":["DIN 10372:2001-01"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe / Tobacco products Zawartość propylenoglikolu i glicerolu / Content of propylene glycol and glycerol\nZakres:\nZakres (0,3 – 5,0) % suchej masy\nScope ((0,3 – 5,0) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method DIN 10372:2001-01 Wyroby tytoniowe / Tobacco products Zawartosc propylenoglikolu i glicerolu / Content of propylene glycol and glycerol\nZakres:\nZakres (0,3 – 5,0) % suchej masy\nScope ((0,3 – 5,0) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) / HPLC-RID Method DIN 10372:2001-01","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,3 – 5,0) % suchej masy"},{"name":"Scope","range":"((0,3 – 5,0) % dwb"}],"search_en":"Range Scope DIN 10372:2001-01","parameters_zh":[{"name":"范围","range":"(0,3 – 5,0) % suchej masy"},{"name":"范围","range":"((0,3 – 5,0) % dwb"}],"search_zh":"范围 范围 DIN 10372:2001-01"},{"_id":"6a82e5e4884ede9a1b2c3fde","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Wyroby tytoniowe / Tobacco products","methodology":"Zawartość sacharozy, glukozy i fruktozy / Content of sucrose, glucose and fructose","parameters":[{"name":"Zakres","range":"(0,3 – 12,5) % suchej masy"},{"name":"Scope","range":"(0,3 – 12,5) % dwb"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","HPLC-RID Method"],"computed":[],"activity":"Zawartość sacharozy, glukozy i fruktozy / Content of sucrose, glucose and fructose\nZakres:\nZakres (0,3 – 12,5) % suchej masy\nScope (0,3 – 12,5) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method","reference":"DIN 10371:2001-01","norm_bases":["DIN 10371:2001-01"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe / Tobacco products Zawartość sacharozy, glukozy i fruktozy / Content of sucrose, glucose and fructose\nZakres:\nZakres (0,3 – 12,5) % suchej masy\nScope (0,3 – 12,5) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) / HPLC-RID Method DIN 10371:2001-01 Wyroby tytoniowe / Tobacco products Zawartosc sacharozy, glukozy i fruktozy / Content of sucrose, glucose and fructose\nZakres:\nZakres (0,3 – 12,5) % suchej masy\nScope (0,3 – 12,5) % dwb\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) / HPLC-RID Method DIN 10371:2001-01","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,3 – 12,5) % suchej masy"},{"name":"Scope","range":"(0,3 – 12,5) % dwb"}],"search_en":"Range Scope DIN 10371:2001-01","parameters_zh":[{"name":"范围","range":"(0,3 – 12,5) % suchej masy"},{"name":"范围","range":"(0,3 – 12,5) % dwb"}],"search_zh":"范围 范围 DIN 10371:2001-01"},{"_id":"6a82e5e4884ede9a1b2c3fdf","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Wyroby tytoniowe / Tobacco products","methodology":"Zawartość jonu amonowego / Ammonium ion content","parameters":[{"name":"Zakres","range":"(0,06 – 0,50) % suchej masy"},{"name":"Scope","range":"(0,06 – 0,50)% dwb"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną / Continuous flow analysis method with spectrophotometric detection (CFA)","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","Continuous flow analysis method with spectrophotometric detection (CFA)"],"computed":[],"activity":"Zawartość jonu amonowego / Ammonium ion content\nZakres:\nZakres (0,06 – 0,50) % suchej masy\nScope (0,06 – 0,50)% dwb\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną / Continuous flow analysis method with spectrophotometric detection (CFA)","reference":"TM048, ed. 1 z 23.09.2019","norm_bases":["TM048, ed. 1 z 23.09.2019"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe / Tobacco products Zawartość jonu amonowego / Ammonium ion content\nZakres:\nZakres (0,06 – 0,50) % suchej masy\nScope (0,06 – 0,50)% dwb\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną / Continuous flow analysis method with spectrophotometric detection (CFA) TM048, ed. 1 z 23.09.2019 Wyroby tytoniowe / Tobacco products Zawartosc jonu amonowego / Ammonium ion content\nZakres:\nZakres (0,06 – 0,50) % suchej masy\nScope (0,06 – 0,50)% dwb\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna / Continuous flow analysis method with spectrophotometric detection (CFA) TM048, ed. 1 z 23.09.2019","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,06 – 0,50) % suchej masy"},{"name":"Scope","range":"(0,06 – 0,50)% dwb"}],"search_en":"Range Scope TM048, ed. 1 z 23.09.2019","parameters_zh":[{"name":"范围","range":"(0,06 – 0,50) % suchej masy"},{"name":"范围","range":"(0,06 – 0,50)% dwb"}],"search_zh":"范围 范围 TM048, ed. 1 z 23.09.2019"},{"_id":"6a82e5e4884ede9a1b2c3fe0","lab_id":"69ad52a3de79e566650fb7ec","country":"PL","accr_number":"AB 1520","accr_body":"PCA","test_object":"Wyroby tytoniowe / Tobacco products","methodology":"Zawartość wody / Water content","parameters":[{"name":"Zakres","range":"(7 – 22) %"},{"name":"Scope","range":"(7 – 22) %"}],"technique":"Metoda miareczkowa / Titration method","techniques":["Metoda miareczkowa","Titration method"],"computed":[],"activity":"Zawartość wody / Water content\nZakres:\nZakres (7 – 22) %\nScope (7 – 22) %\nMetoda miareczkowa / Titration method","reference":"ISO 6488:2021-06 | ISO 6488:2021/Cor.1:2021-10","norm_bases":["ISO 6488:2021-06","ISO 6488:2021/Cor.1:2021-10"],"lab_section":"Laboratorium Chemiczne ITPL; Jankowice ul. Przemysłowa 1; 62-080-Tarnowo Podgórne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe / Tobacco products Zawartość wody / Water content\nZakres:\nZakres (7 – 22) %\nScope (7 – 22) %\nMetoda miareczkowa / Titration method ISO 6488:2021-06 | ISO 6488:2021/Cor.1:2021-10 Wyroby tytoniowe / Tobacco products Zawartosc wody / Water content\nZakres:\nZakres (7 – 22) %\nScope (7 – 22) %\nMetoda miareczkowa / Titration method ISO 6488:2021-06 | ISO 6488:2021/Cor.1:2021-10","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(7 – 22) %"},{"name":"Scope","range":"(7 – 22) %"}],"search_en":"Range Scope ISO 6488:2021-06 | ISO 6488:2021/Cor.1:2021-10","parameters_zh":[{"name":"范围","range":"(7 – 22) %"},{"name":"范围","range":"(7 – 22) %"}],"search_zh":"范围 范围 ISO 6488:2021-06 | ISO 6488:2021/Cor.1:2021-10"}],"has_pdf":true}