{"lab":{"_id":"69ad52a3de79e566650fb7ea","accr_number":"AB 1518","country":"PL","accr_body":"PCA","address":"ul. Sienkiewicza 65, 15-003 Białystok, LABORATORIUM KRYMINALISTYCZNE, ul. Gen. Józefa Bema 4","categories":["other"],"city":"Białystok","imported_at":"2026-03-08T10:42:43.265Z","methods_count":2,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1518.pdf"],"scope_summary":"","search_text":"komenda wojewódzka policji w białymstoku ul. sienkiewicza 65, 15-003 białystok, laboratorium kryminalistyczne, ul. gen. józefa bema 4 materials automotive pharma other food","status":"active","updated_at":"2026-03-08T14:50:40.065Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:42:42.179Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201518,podmiot.html","parse_date":"2026-08-17T10:42:42.179Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"I/17","pl":"Badania w dziedzinie nauk sądowych wyrobów innych","en":"Forensic tests of and other products","de":"Forensische Untersuchungen sonstiger Erzeugnisse","zh":"其他产品的法庭科学检测","cs":"Forenzní zkoušky jiných výrobků"}],"issue":{"no":"11","date":"27.05.2026"},"map_coord":[53.139063,23.169132],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","street":"ul. Sienkiewicza 65","postal_code":"15-003","city":"Białystok","is_hq":true,"address":"ul. Sienkiewicza 65, 15-003 Białystok","site":"15-003|sienkiewicza65"},{"code":null,"name":"LABORATORIUM KRYMINALISTYCZNE","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"},{"code":null,"name":"Pracownia Daktyloskopii","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/0c07ba89cb18f8f657c5eb2cc7ac7e5d/AB%201518.pdf","has_en":true,"category_counts":{"other":2},"category_scores":{"other":2},"has_zh":true,"lab_locations_en":[{"code":null,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","street":"ul. Sienkiewicza 65","postal_code":"15-003","city":"Białystok","is_hq":true,"address":"ul. Sienkiewicza 65, 15-003 Białystok","site":"15-003|sienkiewicza65"},{"code":null,"name":"FORENSIC LABORATORY","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"},{"code":null,"name":"Dactyloscopy Laboratory","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"}],"has_de":true,"lab_locations_de":[{"code":null,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","street":"ul. Sienkiewicza 65","postal_code":"15-003","city":"Białystok","is_hq":true,"address":"ul. Sienkiewicza 65, 15-003 Białystok","site":"15-003|sienkiewicza65"},{"code":null,"name":"KRIMINALTECHNISCHES LABOR","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"},{"code":null,"name":"Labor für Daktyloskopie","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"}],"lab_locations_zh":[{"code":null,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","street":"ul. Sienkiewicza 65","postal_code":"15-003","city":"Białystok","is_hq":true,"address":"ul. Sienkiewicza 65, 15-003 Białystok","site":"15-003|sienkiewicza65"},{"code":null,"name":"刑事技术实验室","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"},{"code":null,"name":"指纹鉴定实验室","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"}],"has_cs":true,"pelny_cs":true,"lab_locations_cs":[{"code":null,"name":"KOMENDA WOJEWÓDZKA POLICJI W BIAŁYMSTOKU","street":"ul. Sienkiewicza 65","postal_code":"15-003","city":"Białystok","is_hq":true,"address":"ul. Sienkiewicza 65, 15-003 Białystok","site":"15-003|sienkiewicza65"},{"code":null,"name":"KRIMINALISTICKÁ LABORATOŘ","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"},{"code":null,"name":"Daktyloskopická laboratoř","street":"ul. Gen. Józefa Bema 4","postal_code":"15-369","city":"Białystok","is_hq":false,"address":"ul. Gen. Józefa Bema 4, 15-369 Białystok","site":"15-369|genjózefabema4"}]},"methods":[{"_id":"6a82e5a2884ede9a1b2c3f15","lab_id":"69ad52a3de79e566650fb7ea","country":"PL","accr_number":"AB 1518","accr_body":"PCA","test_object":"Podłoża – nośniki śladów linii papilarnych","methodology":"Wizualizacja śladów daktyloskopijnych","parameters":[],"technique":null,"techniques":["Badania wizualne","DFO","Ninhydryna","1,2-IND","Polimeryzacja cyjanoakrylanów","Basic Yellow 40","Proszki daktyloskopijne typu: ferromagnetyczne, lekkie, specjalne","Wet Powder","Small Particle Reagent (SPR)","Amido Black","Acid Yellow 7","Hungarian Red","DMAC","Sudan Black"],"computed":[],"activity":"Wizualizacja śladów daktyloskopijnych","reference":"PB-01/DAK wydanie 13 z dnia 19.03.2026","norm_bases":["PB-01/DAK wydanie 13 z dnia 19.03.2026"],"lab_section":"Pracownia Daktyloskopii","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego postanowieniami Decyzji Ramowej Rady 2009/905/WSiSW z dnia 30 listopada 2009 r.","flexible":false,"search_text":"Podłoża – nośniki śladów linii papilarnych Wizualizacja śladów daktyloskopijnych PB-01/DAK wydanie 13 z dnia 19.03.2026 Podloza – nosniki sladow linii papilarnych Wizualizacja sladow daktyloskopijnych PB-01/DAK wydanie 13 z dnia 19.03.2026","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Visualisation of fingerprint traces","search_en":"Substrates – carriers of papillary line traces Visualisation of fingerprint traces Dactyloscopy Laboratory Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009. Visual testing DFO Ninhydrin 1,2-IND Cyanoacrylate polymerisation Basic Yellow 40 Fingerprint powders of the type: ferromagnetic, light, special Wet Powder Small Particle Reagent (SPR) Amido Black Acid Yellow 7 Hungarian Red DMAC Sudan Black PB-01/DAK issue 13 of 19.03.2026","test_object_en":"Substrates – carriers of papillary line traces","search_zh":"承痕体 － 指纹痕迹载体 指纹痕迹的显现 指纹鉴定实验室 为理事会 2009 年 11 月 30 日第 2009/905/JHA 号框架决定规定的法定管制领域开展的检测 目视检验 DFO 茚三酮 1,2-IND 氰基丙烯酸酯聚合 碱性黄 40 (Basic Yellow 40) 指纹显现粉，类型：铁磁性、轻质、特殊 湿粉 (Wet Powder) 小颗粒试剂 (SPR) 氨基黑 (Amido Black) 酸性黄 7 (Acid Yellow 7) 匈牙利红 (Hungarian Red) DMAC 苏丹黑 PB-01/DAK 第13版（2026年3月19日）","test_object_zh":"承痕体 － 指纹痕迹载体","methodology_zh":"指纹痕迹的显现","lab_section_en":"Dactyloscopy Laboratory","regulatory_area_en":"Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009.","techniques_en":["Visual testing","DFO","Ninhydrin","1,2-IND","Cyanoacrylate polymerisation","Basic Yellow 40","Fingerprint powders of the type: ferromagnetic, light, special","Wet Powder","Small Particle Reagent (SPR)","Amido Black","Acid Yellow 7","Hungarian Red","DMAC","Sudan Black"],"lab_section_de":"Labor für Daktyloskopie","methodology_de":"Sichtbarmachung daktyloskopischer Spuren","regulatory_area_de":"Prüfungen für Zwecke des geregelten Bereichs gemäß den Bestimmungen des Rahmenbeschlusses 2009/905/JI des Rates vom 30. November 2009","search_de":"Untergründe – Träger von Papillarleistenspuren Sichtbarmachung daktyloskopischer Spuren Labor für Daktyloskopie Prüfungen für Zwecke des geregelten Bereichs gemäß den Bestimmungen des Rahmenbeschlusses 2009/905/JI des Rates vom 30. November 2009 Sichtprüfungen DFO Ninhydrin 1,2-IND Cyanacrylat-Polymerisation Basic Yellow 40 Daktyloskopische Pulver der Typen: ferromagnetisch, leicht, speziell Nasspulver Small Particle Reagent (SPR) Amidoschwarz Acid Yellow 7 Hungarian Red DMAC Sudanschwarz PB-01/DAK Ausgabe 13 vom 19.03.2026","techniques_de":["Sichtprüfungen","DFO","Ninhydrin","1,2-IND","Cyanacrylat-Polymerisation","Basic Yellow 40","Daktyloskopische Pulver der Typen: ferromagnetisch, leicht, speziell","Nasspulver","Small Particle Reagent (SPR)","Amidoschwarz","Acid Yellow 7","Hungarian Red","DMAC","Sudanschwarz"],"test_object_de":"Untergründe – Träger von Papillarleistenspuren","lab_section_zh":"指纹鉴定实验室","regulatory_area_zh":"为理事会 2009 年 11 月 30 日第 2009/905/JHA 号框架决定规定的法定管制领域开展的检测","techniques_zh":["目视检验","DFO","茚三酮","1,2-IND","氰基丙烯酸酯聚合","碱性黄 40 (Basic Yellow 40)","指纹显现粉，类型：铁磁性、轻质、特殊","湿粉 (Wet Powder)","小颗粒试剂 (SPR)","氨基黑 (Amido Black)","酸性黄 7 (Acid Yellow 7)","匈牙利红 (Hungarian Red)","DMAC","苏丹黑"],"reference_en":"PB-01/DAK issue 13 of 19.03.2026","reference_de":"PB-01/DAK Ausgabe 13 vom 19.03.2026","reference_zh":"PB-01/DAK 第13版（2026年3月19日）","regulatory_area_cs":"Zkoušky prováděné pro účely oblasti regulované ustanoveními rámcového rozhodnutí Rady 2009/905/SVV ze dne 30. listopadu 2009.","search_cs":"Podklady – nosiče stop papilárních linií Zviditelnění daktyloskopických stop Daktyloskopická laboratoř Zkoušky prováděné pro účely oblasti regulované ustanoveními rámcového rozhodnutí Rady 2009/905/SVV ze dne 30. listopadu 2009. Vizuální zkoušky DFO Ninhydrin 1,2-IND Polymerace kyanoakrylátů Basic Yellow 40 Daktyloskopické prášky typu: feromagnetické, lehké, speciální Wet Powder Small Particle Reagent (SPR) Amido Black Acid Yellow 7 Hungarian Red DMAC Sudan Black PB-01/DAK vydání 13 ze dne 19.03.2026","techniques_cs":["Vizuální zkoušky","DFO","Ninhydrin","1,2-IND","Polymerace kyanoakrylátů","Basic Yellow 40","Daktyloskopické prášky typu: feromagnetické, lehké, speciální","Wet Powder","Small Particle Reagent (SPR)","Amido Black","Acid Yellow 7","Hungarian Red","DMAC","Sudan Black"],"test_object_cs":"Podklady – nosiče stop papilárních linií","lab_section_cs":"Daktyloskopická laboratoř","methodology_cs":"Zviditelnění daktyloskopických stop","reference_cs":"PB-01/DAK vydání 13 ze dne 19.03.2026"},{"_id":"6a82e5a2884ede9a1b2c3f16","lab_id":"69ad52a3de79e566650fb7ea","country":"PL","accr_number":"AB 1518","accr_body":"PCA","test_object":"Odwzorowania linii papilarnych palców, dłoni i stóp","methodology":"Identyfikacja odwzorowań linii papilarnych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Identyfikacja odwzorowań linii papilarnych","reference":"PB-01/DAK wydanie 13 z dnia 19.03.2026","norm_bases":["PB-01/DAK wydanie 13 z dnia 19.03.2026"],"lab_section":"Pracownia Daktyloskopii","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego postanowieniami Decyzji Ramowej Rady 2009/905/WSiSW z dnia 30 listopada 2009 r.","flexible":false,"search_text":"Odwzorowania linii papilarnych palców, dłoni i stóp Identyfikacja odwzorowań linii papilarnych PB-01/DAK wydanie 13 z dnia 19.03.2026 Odwzorowania linii papilarnych palcow, dloni i stop Identyfikacja odwzorowan linii papilarnych PB-01/DAK wydanie 13 z dnia 19.03.2026","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Identification of fingerprint impressions","search_en":"Impressions of finger, palm and foot friction ridges Identification of fingerprint impressions Dactyloscopy Laboratory Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009. PB-01/DAK issue 13 of 19.03.2026","test_object_en":"Impressions of finger, palm and foot friction ridges","methodology_zh":"指纹纹线图像的鉴定","search_zh":"手指、手掌与足部纹线印痕 指纹纹线图像的鉴定 指纹鉴定实验室 为理事会 2009 年 11 月 30 日第 2009/905/JHA 号框架决定规定的法定管制领域开展的检测 PB-01/DAK 第13版（2026年3月19日）","test_object_zh":"手指、手掌与足部纹线印痕","lab_section_en":"Dactyloscopy Laboratory","regulatory_area_en":"Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009.","lab_section_de":"Labor für Daktyloskopie","methodology_de":"Identifizierung von Fingerabdruckspuren","regulatory_area_de":"Prüfungen für Zwecke des geregelten Bereichs gemäß den Bestimmungen des Rahmenbeschlusses 2009/905/JI des Rates vom 30. November 2009","search_de":"Abdrücke der Papillarleisten von Fingern, Handflächen und Füßen Identifizierung von Fingerabdruckspuren Labor für Daktyloskopie Prüfungen für Zwecke des geregelten Bereichs gemäß den Bestimmungen des Rahmenbeschlusses 2009/905/JI des Rates vom 30. November 2009 PB-01/DAK Ausgabe 13 vom 19.03.2026","test_object_de":"Abdrücke der Papillarleisten von Fingern, Handflächen und Füßen","lab_section_zh":"指纹鉴定实验室","regulatory_area_zh":"为理事会 2009 年 11 月 30 日第 2009/905/JHA 号框架决定规定的法定管制领域开展的检测","reference_en":"PB-01/DAK issue 13 of 19.03.2026","reference_de":"PB-01/DAK Ausgabe 13 vom 19.03.2026","reference_zh":"PB-01/DAK 第13版（2026年3月19日）","methodology_cs":"Identifikace otisků papilárních linií","regulatory_area_cs":"Zkoušky prováděné pro účely oblasti regulované ustanoveními rámcového rozhodnutí Rady 2009/905/SVV ze dne 30. listopadu 2009.","search_cs":"Otisky papilárních linií prstů, dlaní a chodidel Identifikace otisků papilárních linií Daktyloskopická laboratoř Zkoušky prováděné pro účely oblasti regulované ustanoveními rámcového rozhodnutí Rady 2009/905/SVV ze dne 30. listopadu 2009. PB-01/DAK vydání 13 ze dne 19.03.2026","lab_section_cs":"Daktyloskopická laboratoř","reference_cs":"PB-01/DAK vydání 13 ze dne 19.03.2026","test_object_cs":"Otisky papilárních linií prstů, dlaní a chodidel"}],"has_pdf":true}