{"lab":{"_id":"69ad52a3de79e566650fb7d4","accr_number":"AB 1503","country":"PL","accr_body":"PCA","address":"ul. Sokołowska 29/37, 01-142 Warszawa, LABORATORIUM NANOSTRUKTUR, Al. Prymasa Tysiąclecia 98","categories":["materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":5,"name":"INSTYTUT WYSOKICH CIŚNIEŃ POLSKIEJ AKADEMII NAUK","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1503.pdf"],"scope_summary":"","search_text":"instytut wysokich ciśnień polskiej akademii nauk ul. sokołowska 29/37, 01-142 warszawa, laboratorium nanostruktur, al. prymasa tysiąclecia 98 other materials","status":"active","updated_at":"2026-03-08T14:50:39.418Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:01:02.285Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201503,podmiot.html","parse_date":"2026-08-13T08:01:02.285Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"N/4; N/8; N/12; N/21","pl":"Badania właściwości fizycznych wyrobów chemicznych, wyrobów i materiałów konstrukcyjnych, szkła i ceramiki, wyrobów z tworzyw sztucznych","en":"Tests of physical properties of chemical products; construction products and materials; glass and ceramics; plastic and rubber products"}],"issue":{"no":"12","date":"06.03.2026"},"map_coord":[52.238804,20.958881],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM NANOSTRUKTUR","address":"Al. Prymasa Tysiąclecia 98","city":null,"postal":null},{"name":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/d2f99e22252a59223735944f53819a43/AB%201503.pdf","has_en":true,"category_counts":{"materials":5},"category_scores":{"materials":5},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM NANOSTRUKTUR","address":"Al. Prymasa Tysiąclecia 98","city":null,"postal":null},{"name":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79be0636ba417e41acd9","lab_id":"69ad52a3de79e566650fb7d4","country":"PL","accr_number":"AB 1503","accr_body":"PCA","test_object":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika","methodology":"Średnia wielkość cząstek/ aglomeratów w cieczach","parameters":[{"name":"Zakres","range":"(20 - 450) nm"}],"technique":"Metoda dynamicznego rozpraszania światła (DLS)","techniques":["Metoda dynamicznego rozpraszania światła (DLS)"],"computed":[],"activity":"Średnia wielkość cząstek/ aglomeratów w cieczach\nZakres (20 - 450) nm\nMetoda dynamicznego rozpraszania światła (DLS)","reference":"ISO 22412:2008","norm_bases":["ISO 22412:2008"],"lab_section":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Średnia wielkość cząstek/ aglomeratów w cieczach\nZakres (20 - 450) nm\nMetoda dynamicznego rozpraszania światła (DLS) ISO 22412:2008 Probki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Srednia wielkosc czastek/ aglomeratow w cieczach\nZakres (20 - 450) nm\nMetoda dynamicznego rozpraszania swiatla (DLS) ISO 22412:2008","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","methodology_en":"Average size of particles/ agglomerates in liquids","parameters_en":[{"name":"Range","range":"(20 - 450) nm"}],"search_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics Average size of particles/ agglomerates in liquids Dynamic light scattering method (DLS) Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa Range ISO 22412:2008","technique_en":"Dynamic light scattering method (DLS)","test_object_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics","parameters_zh":[{"name":"范围","range":"(20 - 450) nm"}],"search_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷 纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙 范围 ISO 22412:2008","lab_section_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙","test_object_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷"},{"_id":"6a7d79be0636ba417e41acda","lab_id":"69ad52a3de79e566650fb7d4","country":"PL","accr_number":"AB 1503","accr_body":"PCA","test_object":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika","methodology":"Średnia wielkość cząstek/ aglomeratów i rozkład wielkości cząstek/ aglomeratów w cieczach","parameters":[{"name":"Zakres","range":"(20 - 450) nm"}],"technique":"Metoda detekcji i analizy toru ruchu nanocząstek (NTA)","techniques":["Metoda detekcji i analizy toru ruchu nanocząstek (NTA)"],"computed":[],"activity":"Średnia wielkość cząstek/ aglomeratów i rozkład wielkości cząstek/ aglomeratów w cieczach\nZakres (20 - 450) nm\nMetoda detekcji i analizy toru ruchu nanocząstek (NTA)","reference":"ASTM E2834-12","norm_bases":["ASTM E2834-12"],"lab_section":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Średnia wielkość cząstek/ aglomeratów i rozkład wielkości cząstek/ aglomeratów w cieczach\nZakres (20 - 450) nm\nMetoda detekcji i analizy toru ruchu nanocząstek (NTA) ASTM E2834-12 Probki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Srednia wielkosc czastek/ aglomeratow i rozklad wielkosci czastek/ aglomeratow w cieczach\nZakres (20 - 450) nm\nMetoda detekcji i analizy toru ruchu nanoczastek (NTA) ASTM E2834-12","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","methodology_en":"Average size of particles/ agglomerates and size distribution of particles/ agglomerates in liquids","parameters_en":[{"name":"Range","range":"(20 - 450) nm"}],"search_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics Average size of particles/ agglomerates and size distribution of particles/ agglomerates in liquids Nanoparticle tracking analysis method (NTA) Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa Range ASTM E2834-12","technique_en":"Nanoparticle tracking analysis method (NTA)","test_object_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics","parameters_zh":[{"name":"范围","range":"(20 - 450) nm"}],"search_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷 纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙 范围 ASTM E2834-12","lab_section_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙","test_object_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷"},{"_id":"6a7d79be0636ba417e41acdb","lab_id":"69ad52a3de79e566650fb7d4","country":"PL","accr_number":"AB 1503","accr_body":"PCA","test_object":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika","methodology":"Potencjał zeta","parameters":[{"name":"Zakres","range":"od -40 mV do 40 mV"},{"name":"Dopplerowskiej (LDE)"}],"technique":"Metoda laserowej elektroforezy","techniques":["Metoda laserowej elektroforezy"],"computed":[],"activity":"Potencjał zeta\nZakres:\nZakres od -40 mV do 40 mV\nDopplerowskiej (LDE)\nMetoda laserowej elektroforezy","reference":"ISO 13099-1:2012 | ISO 13099-2:2012","norm_bases":["ISO 13099-1:2012","ISO 13099-2:2012"],"lab_section":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Potencjał zeta\nZakres:\nZakres od -40 mV do 40 mV\nDopplerowskiej (LDE)\nMetoda laserowej elektroforezy ISO 13099-1:2012 | ISO 13099-2:2012 Probki zawiesin: chemikalia, metale, kompozyty, polimery i ceramika Potencjal zeta\nZakres:\nZakres od -40 mV do 40 mV\nDopplerowskiej (LDE)\nMetoda laserowej elektroforezy ISO 13099-1:2012 | ISO 13099-2:2012","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","methodology_en":"Zeta potential","parameters_en":[{"name":"Range","range":"od -40 mV do 40 mV"},{"name":"Doppler (LDE)"}],"search_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics Zeta potential Laser electrophoresis method Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa Range Doppler (LDE) ISO 13099-1:2012 | ISO 13099-2:2012","technique_en":"Laser electrophoresis method","test_object_en":"Suspension samples: chemicals, metals, composites, polymers and ceramics","parameters_zh":[{"name":"范围","range":"od -40 mV do 40 mV"},{"name":"Dopplerowskiej (LDE)"}],"search_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷 纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙 范围 ISO 13099-1:2012 | ISO 13099-2:2012","lab_section_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙","test_object_zh":"悬浮液样品：化学品、金属、复合材料、聚合物与陶瓷"},{"_id":"6a7d79be0636ba417e41acdc","lab_id":"69ad52a3de79e566650fb7d4","country":"PL","accr_number":"AB 1503","accr_body":"PCA","test_object":"Próbki stałe: chemikalia w tym farby; materiały konstrukcyjne w tym metale, kompozyty, szkło, ceramika, tworzywa syntetyczne","methodology":"Gęstość szkieletowa","parameters":[{"name":"objętość próbki","range":"(0,72 - 6,37) cm3"}],"technique":"Metoda piknometrii helowej","techniques":["Metoda piknometrii helowej"],"computed":[],"activity":"Gęstość szkieletowa\nobjętość próbki (0,72 - 6,37) cm3\nMetoda piknometrii helowej","reference":"ISO 12154:2014","norm_bases":["ISO 12154:2014"],"lab_section":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki stałe: chemikalia w tym farby; materiały konstrukcyjne w tym metale, kompozyty, szkło, ceramika, tworzywa syntetyczne Gęstość szkieletowa\nobjętość próbki (0,72 - 6,37) cm3\nMetoda piknometrii helowej ISO 12154:2014 Probki stale: chemikalia w tym farby; materialy konstrukcyjne w tym metale, kompozyty, szklo, ceramika, tworzywa syntetyczne Gestosc szkieletowa\nobjetosc probki (0,72 - 6,37) cm3\nMetoda piknometrii helowej ISO 12154:2014","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","methodology_en":"Skeletal density","parameters_en":[{"name":"sample volume","range":"(0,72 - 6,37) cm3"}],"search_en":"Solid samples: chemicals including paints; construction materials including metals, composites, glass, ceramics, synthetic plastics Skeletal density Helium pycnometry method Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa sample volume ISO 12154:2014","technique_en":"Helium pycnometry method","test_object_en":"Solid samples: chemicals including paints; construction materials including metals, composites, glass, ceramics, synthetic plastics","lab_section_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙","search_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙 ISO 12154:2014"},{"_id":"6a7d79be0636ba417e41acdd","lab_id":"69ad52a3de79e566650fb7d4","country":"PL","accr_number":"AB 1503","accr_body":"PCA","test_object":"Próbki stałe: chemikalia w tym farby; materiały konstrukcyjne w tym metale, kompozyty, szkło, ceramika","methodology":"Powierzchnia właściwa BET","parameters":[{"name":"Zakres","range":"powierzchnia właściwa"},{"name":"Zakres","range":"(1 - 550) m2/g"}],"technique":"Metoda sorpcji fizycznej","techniques":["Metoda sorpcji fizycznej"],"computed":[],"activity":"Powierzchnia właściwa BET\nZakres:\nZakres powierzchnia właściwa\nZakres (1 - 550) m2/g\nMetoda sorpcji fizycznej","reference":"ISO 9277:2010","norm_bases":["ISO 9277:2010"],"lab_section":"Laboratorium Nanostruktur; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki stałe: chemikalia w tym farby; materiały konstrukcyjne w tym metale, kompozyty, szkło, ceramika Powierzchnia właściwa BET\nZakres:\nZakres powierzchnia właściwa\nZakres (1 - 550) m2/g\nMetoda sorpcji fizycznej ISO 9277:2010 Probki stale: chemikalia w tym farby; materialy konstrukcyjne w tym metale, kompozyty, szklo, ceramika Powierzchnia wlasciwa BET\nZakres:\nZakres powierzchnia wlasciwa\nZakres (1 - 550) m2/g\nMetoda sorpcji fizycznej ISO 9277:2010","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa","methodology_en":"BET specific surface area","parameters_en":[{"name":"Range","range":"powierzchnia właściwa"},{"name":"Range","range":"(1 - 550) m2/g"}],"search_en":"Solid samples: chemicals including paints; construction materials including metals, composites, glass, ceramics BET specific surface area Physical sorption method Nanostructures Laboratory; Al. Prymasa Tysiąclecia 98, 01-424 Warszawa Range Range ISO 9277:2010","technique_en":"Physical sorption method","test_object_en":"Solid samples: chemicals including paints; construction materials including metals, composites, glass, ceramics","parameters_zh":[{"name":"范围","range":"powierzchnia właściwa"},{"name":"范围","range":"(1 - 550) m2/g"}],"search_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙 范围 范围 ISO 9277:2010","lab_section_zh":"纳米结构实验室；Al. Prymasa Tysiąclecia 98, 01-424 华沙"}],"has_pdf":true}