{"lab":{"_id":"69ad52a3de79e566650fb7ba","accr_number":"AB 1488","country":"PL","accr_body":"PCA","address":"ul. Warkocz 3-5, 25-253 Kielce, LABORATORIUM BADAŃ ŚRODOWISKOWYCH BARWA, ul. Cedzyńska 40","categories":["water","environment","microbiology"],"city":"Kielce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":90,"name":"F.H. BARWA JAROSŁAW CZAJKOWSKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1488.pdf"],"scope_summary":"","search_text":"f.h. barwa jarosław czajkowski ul. warkocz 3-5, 25-253 kielce, laboratorium badań środowiskowych barwa, ul. cedzyńska 40 other environment water pharma electronics materials food microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:38.507Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:38.507Z","email_confidence":"high","email_mx":true,"email_source":"https://www.barwa.kielce.pl/en/contact","parse_date":"2026-07-17T16:19:08.495Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/24","pl":"Badania chemiczne wyrobów tytoniowych","en":"Chemical tests of tobacco products"},{"codes":"C/28/P","pl":"Badania chemiczne i pobieranie próbek wody","en":"Chemical tests and sampling of water"},{"codes":"C/29/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests and sampling of drinking water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"K/29/P","pl":"Badania właściwości mikrobiologicznych i pobieranie próbek wody do spożycia","en":""},{"codes":"N/28P","pl":"Badania właściwości fizycznych i pobieranie próbek wody","en":"Tests of physical properties and sampling of water"},{"codes":"N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of drinking water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/30","pl":"Pobieranie próbek ścieków","en":"Sampling of sewage"},{"codes":"P/31","pl":"Pobieranie próbek gleby","en":"Sampling of soil"},{"codes":"P/32","pl":"Pobieranie próbek osadów, odpadów","en":"Sampling of sediments, waste"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"},{"codes":"Q/28","pl":"Badania sensoryczne wody","en":"Sensory tests of water"}],"issue":{"no":"14","date":"08.01.2026"},"map_coord":[50.862077,20.705406],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":50,"other":22,"environment":17,"microbiology":5,"materials":4,"electronics":1},"category_scores":{"water":25.25,"other":4.89,"environment":2.92,"microbiology":0.25,"materials":0.16,"electronics":0.01},"has_zh":true},"methods":[{"_id":"6a5a55fc9af9f73f38252fca","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych >10Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures >10Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych >10Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych >10Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych >10Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures >10Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fcb","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość Zakres: (0,50 - 20) m/s Metoda anemometryczna","methodology_en":"Velocity Range: (0,50 - 20) m/s Anemometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość Zakres: (0,50 - 20) m/s Metoda anemometryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość Zakres: (0,50 - 20) m/s Metoda anemometryczna Gazy odlotowe Predkosc Zakres: (0,50 - 20) m/s Metoda anemometryczna","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Velocity Range: (0,50 - 20) m/s Anemometric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fcc","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55fc9af9f73f38252fcd","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,00030 – 7,0) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,00030 – 7,0) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,00030 – 7,0) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,00030 – 7,0) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,00030 – 7,0) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,00030 – 7,0) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fce","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55fc9af9f73f38252fcf","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55fc9af9f73f38252fd0","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,00030 – 0,050) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,00030 – 0,050) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,00030 – 0,050) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,00030 – 0,050) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,00030 – 0,050) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,00030 – 0,050) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd1","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie całkowite węgla organicznego (TVOC) Zakres: (1,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej FID","methodology_en":"Total organic carbon concentration (TVOC) Range: (1,0 – 1000) mg/m3 Continuous flame ionisation detection method FID","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie całkowite węgla organicznego (TVOC) Zakres: (1,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej FID","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie całkowite węgla organicznego (TVOC) Zakres: (1,0 – 1000) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej FID PN-EN 12619:2013-05 Gazy odlotowe Stezenie calkowite wegla organicznego (TVOC) Zakres: (1,0 – 1000) mg/m3 Metoda ciaglej detekcji plomieniowo-jonizacyjnej FID PN-EN 12619:2013-05","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Total organic carbon concentration (TVOC) Range: (1,0 – 1000) mg/m3 Continuous flame ionisation detection method FID PN-EN 12619:2013-05","search_zh":"废气 PN-EN 12619:2013-05","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd2","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja (TVOC) (z obliczeń)","methodology_en":"Emission (TVOC) (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja (TVOC) (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja (TVOC) (z obliczeń) Gazy odlotowe Emisja (TVOC) (z obliczen)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission (TVOC) (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd3","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Metoda chemiluminescencyjna","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides Range: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Metoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 PN ISO 10396:2001","norm_bases":["PN-EN 14792:2017-04 PN ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu Zakres: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Metoda chemiluminescencyjna PN-EN 14792:2017-04 PN ISO 10396:2001 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu Zakres: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Metoda chemiluminescencyjna PN-EN 14792:2017-04 PN ISO 10396:2001","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: NO (4 – 1205) mg/m3 NOx (6 – 1848) mg/m3 Chemiluminescence method PN-EN 14792:2017-04 PN ISO 10396:2001","search_zh":"废气 PN-EN 14792:2017-04 PN ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd4","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO i NOx w przeliczeniu na NO2(z obliczeń)","methodology_en":"Emission of NO and NOx calculated as NO2(calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO i NOx w przeliczeniu na NO2(z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO i NOx w przeliczeniu na NO2(z obliczeń) Gazy odlotowe Emisja NO i NOx w przeliczeniu na NO2(z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO and NOx calculated as NO2(calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd5","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki Zakres: (6 – 2572) mg/m3 Metoda NDIR","methodology_en":"Sulphur dioxide concentration Range: (6 – 2572) mg/m3 NDIR method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki Zakres: (6 – 2572) mg/m3 Metoda NDIR","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki Zakres: (6 – 2572) mg/m3 Metoda NDIR PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki Zakres: (6 – 2572) mg/m3 Metoda NDIR PN-ISO 10396:2001","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sulphur dioxide concentration Range: (6 – 2572) mg/m3 NDIR method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd6","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja dwutlenku siarki (z obliczeń)","methodology_en":"Sulphur dioxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja dwutlenku siarki (z obliczeń) Gazy odlotowe Emisja dwutlenku siarki (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sulphur dioxide emission (calculated)","search_zh":"废气 二氧化硫排放（由计算得出）","test_object_zh":"废气","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fd7","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla Zakres: (4 – 2200) mg/m3 Metoda NDIR","methodology_en":"Carbon monoxide concentration Range: (4 – 2200) mg/m3 NDIR method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (4 – 2200) mg/m3 Metoda NDIR","reference":"PN-EN 15058:2017-04 PN ISO 10396:2001","norm_bases":["PN-EN 15058:2017-04 PN ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla Zakres: (4 – 2200) mg/m3 Metoda NDIR PN-EN 15058:2017-04 PN ISO 10396:2001 Gazy odlotowe Stezenie tlenku wegla Zakres: (4 – 2200) mg/m3 Metoda NDIR PN-EN 15058:2017-04 PN ISO 10396:2001","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide concentration Range: (4 – 2200) mg/m3 NDIR method PN-EN 15058:2017-04 PN ISO 10396:2001","search_zh":"废气 PN-EN 15058:2017-04 PN ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fd8","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku węgla (z obliczeń)","methodology_en":"Carbon monoxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) Gazy odlotowe Emisja tlenku wegla (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide emission (calculated)","search_zh":"废气 一氧化碳排放（由计算得出）","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fd9","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu Zakres: (1 – 21,1) % Metoda paramagnetyczna","methodology_en":"Oxygen concentration Range: (1 – 21,1) % Paramagnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu Zakres: (1 – 21,1) % Metoda paramagnetyczna","reference":"PN-EN 14789:2017-04 PN ISO 10396:2001","norm_bases":["PN-EN 14789:2017-04 PN ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu Zakres: (1 – 21,1) % Metoda paramagnetyczna PN-EN 14789:2017-04 PN ISO 10396:2001 Gazy odlotowe Stezenie tlenu Zakres: (1 – 21,1) % Metoda paramagnetyczna PN-EN 14789:2017-04 PN ISO 10396:2001","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Range: (1 – 21,1) % Paramagnetic method PN-EN 14789:2017-04 PN ISO 10396:2001","search_zh":"废气 PN-EN 14789:2017-04 PN ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fda","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla Zakres: (1 - 21,1) % Metoda NDIR","methodology_en":"Carbon dioxide concentration Range: (1 - 21,1) % NDIR method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla Zakres: (1 - 21,1) % Metoda NDIR","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla Zakres: (1 - 21,1) % Metoda NDIR PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla Zakres: (1 - 21,1) % Metoda NDIR PN-ISO 10396:2001","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon dioxide concentration Range: (1 - 21,1) % NDIR method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fdb","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja dwutlenku węgla (z obliczeń)","methodology_en":"Carbon dioxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja dwutlenku węgla (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja dwutlenku węgla (z obliczeń) Gazy odlotowe Emisja dwutlenku wegla (z obliczen)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon dioxide emission (calculated)","search_zh":"废气 二氧化碳排放（由计算得出）","test_object_zh":"废气","methodology_zh":"二氧化碳排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fdc","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5a55fc9af9f73f38252fdd","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated)","search_zh":"废气 单项气态有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5a55fc9af9f73f38252fde","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru (HCl)","methodology_en":"Sampling for determination of hydrogen chloride (HCl) concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru (HCl)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru (HCl) PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru (HCl) PN-EN 1911:2011","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of hydrogen chloride (HCl) concentration PN-EN 1911:2011","search_zh":"废气 PN-EN 1911:2011","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fdf","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Zawartość chlorowodoru Zakres: (0,080 - 15,0) mg w próbce Metoda spektrofotometryczna","methodology_en":"Hydrogen chloride content Range: (0,080 - 15,0) mg in sample Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorowodoru Zakres: (0,080 - 15,0) mg w próbce Metoda spektrofotometryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Zawartość chlorowodoru Zakres: (0,080 - 15,0) mg w próbce Metoda spektrofotometryczna Gazy odlotowe Zawartosc chlorowodoru Zakres: (0,080 - 15,0) mg w probce Metoda spektrofotometryczna","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Hydrogen chloride content Range: (0,080 - 15,0) mg in sample Spectrophotometric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe0","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja chlorowodoru (z obliczeń)","methodology_en":"Hydrogen chloride emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) Gazy odlotowe Emisja chlorowodoru (z obliczen)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Hydrogen chloride emission (calculated)","search_zh":"废气 氯化氢排放量（计算值）","test_object_zh":"废气","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a5a55fc9af9f73f38252fe1","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania zawartości fluorowodoru (HF)","methodology_en":"Sampling for determination of hydrogen fluoride content (HF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania zawartości fluorowodoru (HF)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania zawartości fluorowodoru (HF) ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania zawartosci fluorowodoru (HF) ISO 15713:2006","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of hydrogen fluoride content (HF) ISO 15713:2006","search_zh":"废气 ISO 15713:2006","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe2","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Zawartość fluorowodoru Zakres: (0,0100 - 100) mg w próbce Metoda potencjometryczna – jonoselektywna","methodology_en":"Hydrogen fluoride content Range: (0,0100 - 100) mg in sample Potentiometric method – ion-selective","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fluorowodoru Zakres: (0,0100 - 100) mg w próbce Metoda potencjometryczna – jonoselektywna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Zawartość fluorowodoru Zakres: (0,0100 - 100) mg w próbce Metoda potencjometryczna – jonoselektywna Gazy odlotowe Zawartosc fluorowodoru Zakres: (0,0100 - 100) mg w probce Metoda potencjometryczna – jonoselektywna","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Hydrogen fluoride content Range: (0,0100 - 100) mg in sample Potentiometric method – ion-selective","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe3","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja fluorowodoru (z obliczeń)","methodology_en":"Hydrogen fluoride emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja fluorowodoru (z obliczeń) Gazy odlotowe Emisja fluorowodoru (z obliczen)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Hydrogen fluoride emission (calculated)","search_zh":"废气 氟化氢排放（由计算得出）","test_object_zh":"废气","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fe4","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania zawartości metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Metoda aspiracyjna","methodology_en":"Sampling for determination of metal content in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Aspiration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania zawartości metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Metoda aspiracyjna","reference":"PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r.","norm_bases":["PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania zawartości metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Metoda aspiracyjna PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r. Gazy odlotowe Pobieranie probek do oznaczania zawartosci metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Metoda aspiracyjna PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r.","categories":["materials"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of metal content in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti, V Aspiration method PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r.","search_zh":"废气 PN-Z-04030-7:1994, PT-1 wydanie 7 z dnia 02.09.2019 r.","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe5","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali w pyle (z obliczeń)","methodology_en":"Emission of metals in dust (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali w pyle (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali w pyle (z obliczeń) Gazy odlotowe Emisja metali w pyle (z obliczen)","categories":["materials","environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of metals in dust (calculated)","search_zh":"废气 粉尘中的金属排放（由计算得出）","test_object_zh":"废气","methodology_zh":"粉尘中的金属排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fe6","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do oznaczenia granulometrycznego","methodology_en":"Dust sampling for particle size determination","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do oznaczenia granulometrycznego","reference":"PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r.","norm_bases":["PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczenia granulometrycznego PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r. Gazy odlotowe Pobieranie probek pylu do oznaczenia granulometrycznego PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r.","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust sampling for particle size determination PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r.","search_zh":"废气 PN-Z-04030-7:1994 PT-1 wydanie 7 z dnia 02.09.2019 r.","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe7","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu (z obliczeń)","methodology_en":"Emission of the dust fraction (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) Gazy odlotowe Emisja frakcji pylu (z obliczen)","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of the dust fraction (calculated)","search_zh":"废气 粉尘分级排放（由计算得出）","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252fe8","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru i kwasu siarkowego (VI)","methodology_en":"Sampling for determination of the concentration of hydrogen sulfide and sulfuric (VI) acid","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru i kwasu siarkowego (VI)","reference":"PT-21 wydanie 2 z dnia 30.10.2023 r.","norm_bases":["PT-21 wydanie 2 z dnia 30.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia siarkowodoru i kwasu siarkowego (VI) PT-21 wydanie 2 z dnia 30.10.2023 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia siarkowodoru i kwasu siarkowego (VI) PT-21 wydanie 2 z dnia 30.10.2023 r.","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of hydrogen sulfide and sulfuric (VI) acid PT-21 wydanie 2 z dnia 30.10.2023 r.","search_zh":"废气 PT-21 wydanie 2 z dnia 30.10.2023 r.","test_object_zh":"废气"},{"_id":"6a5a55fc9af9f73f38252fe9","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","methodology_en":"Sampling for determination of ammonia concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","search_zh":"废气 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨浓度测定采样"},{"_id":"6a5a55fc9af9f73f38252fea","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Środowisko ogólne – gazy składowiskowe","test_object_en":"General environment – landfill gases","methodology":"Stężenie metanu (CH4), ditlenku węgla (CO2) Zakres: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Metoda absorpcji promieniowania w podczerwieni (IR)","methodology_en":"Methane (CH4), carbon dioxide (CO2) concentration Range: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Infrared radiation absorption method (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metanu (CH4), ditlenku węgla (CO2) Zakres: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Metoda absorpcji promieniowania w podczerwieni (IR)","reference":"PT-14 wydanie 1 z dnia 12.05.2020 r.","norm_bases":["PT-14 wydanie 1 z dnia 12.05.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – gazy składowiskowe Stężenie metanu (CH4), ditlenku węgla (CO2) Zakres: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Metoda absorpcji promieniowania w podczerwieni (IR) PT-14 wydanie 1 z dnia 12.05.2020 r. Srodowisko ogolne – gazy skladowiskowe Stezenie metanu (CH4), ditlenku wegla (CO2) Zakres: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Metoda absorpcji promieniowania w podczerwieni (IR) PT-14 wydanie 1 z dnia 12.05.2020 r.","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – landfill gases Methane (CH4), carbon dioxide (CO2) concentration Range: CH4 (0,5 - 65) % CO2 (0,5 - 35) % Infrared radiation absorption method (IR) PT-14 wydanie 1 z dnia 12.05.2020 r.","search_zh":"一般环境 － 填埋气 PT-14 wydanie 1 z dnia 12.05.2020 r.","test_object_zh":"一般环境 － 填埋气"},{"_id":"6a5a55fc9af9f73f38252feb","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Środowisko ogólne – gazy składowiskowe","test_object_en":"General environment – landfill gases","methodology":"Stężenie tlenu (O2) Zakres: (0,5 - 21) % Metoda elektrochemiczna","methodology_en":"Oxygen (O2) concentration Range: (0,5 - 21) % Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu (O2) Zakres: (0,5 - 21) % Metoda elektrochemiczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – gazy składowiskowe Stężenie tlenu (O2) Zakres: (0,5 - 21) % Metoda elektrochemiczna Srodowisko ogolne – gazy skladowiskowe Stezenie tlenu (O2) Zakres: (0,5 - 21) % Metoda elektrochemiczna","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – landfill gases Oxygen (O2) concentration Range: (0,5 - 21) % Electrochemical method","search_zh":"一般环境 － 填埋气","test_object_zh":"一般环境 － 填埋气"},{"_id":"6a5a55fc9af9f73f38252fec","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Środowisko ogólne – gazy składowiskowe","test_object_en":"General environment – landfill gases","methodology":"Emisja ditlenku węgla (CO2), metanu (CH4) (z obliczeń)","methodology_en":"Emission of carbon dioxide (CO2), methane (CH4) (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja ditlenku węgla (CO2), metanu (CH4) (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – gazy składowiskowe Emisja ditlenku węgla (CO2), metanu (CH4) (z obliczeń) Srodowisko ogolne – gazy skladowiskowe Emisja ditlenku wegla (CO2), metanu (CH4) (z obliczen)","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – landfill gases Emission of carbon dioxide (CO2), methane (CH4) (calculated)","search_zh":"一般环境 － 填埋气","test_object_zh":"一般环境 － 填埋气"},{"_id":"6a5a55fc9af9f73f38252fed","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH Zakres: 2,0 - 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 - 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 - 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH Zakres: 2,0 - 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH Zakres: 2,0 - 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater pH Range: 2,0 - 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、生活饮用水、污水 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252fee","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 - 20 000) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 - 20 000) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 - 20 000) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa Zakres: (10 - 20 000) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa Zakres: (10 - 20 000) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Range: (10 - 20 000) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水、污水 PN-EN 27888:1999","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252fef","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chloru wolnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna","methodology_en":"Free chlorine concentration Range: (0,05 - 4,50) mg/l Photometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna","reference":"PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597","norm_bases":["PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chloru wolnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597 Woda, woda do spozycia przez ludzi, scieki Stezenie chloru wolnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Free chlorine concentration Range: (0,05 - 4,50) mg/l Photometric method PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597","search_zh":"水、生活饮用水、污水 PT-5 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK nr 100 597","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff0","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chloru ogólnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna","methodology_en":"Total chlorine concentration Range: (0,05 - 4,50) mg/l Photometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chloru ogólnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna Woda, woda do spozycia przez ludzi, scieki Stezenie chloru ogolnego Zakres: (0,05 - 4,50) mg/l Metoda fotometryczna","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Total chlorine concentration Range: (0,05 - 4,50) mg/l Photometric method","search_zh":"水、生活饮用水、污水","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff1","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chloru związanego, chloraminy (z obliczeń)","methodology_en":"Combined chlorine concentration, chloramines (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego, chloraminy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chloru związanego, chloraminy (z obliczeń) Woda, woda do spozycia przez ludzi, scieki Stezenie chloru zwiazanego, chloraminy (z obliczen)","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Combined chlorine concentration, chloramines (calculated)","search_zh":"水、生活饮用水、污水","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff2","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Indeks nadmanganianowy Zakres: (1,0 - 100) mg/l O2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (1,0 - 100) mg/l O2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (1,0 - 100) mg/l O2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Indeks nadmanganianowy Zakres: (1,0 - 100) mg/l O2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi, scieki Indeks nadmanganianowy Zakres: (1,0 - 100) mg/l O2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Permanganate index Range: (1,0 - 100) mg/l O2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水、生活饮用水、污水 PN-EN ISO 8467:2001","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff3","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,16 - 2,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,16 - 2,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,16 - 2,00) mg/l Metoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego Zakres: (0,16 - 2,00) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego Zakres: (0,16 - 2,00) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Range: (0,16 - 2,00) mg/l Spectrophotometric method PN-C-04576-4:1994","search_zh":"水、生活饮用水、污水 PN-C-04576-4:1994","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff4","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 - 90,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 - 90,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 - 90,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego Zakres: (0,10 - 90,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego Zakres: (0,10 - 90,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Range: (0,10 - 90,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水、生活饮用水、污水 PN-82/C-04576.08","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff5","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,002 - 20,0) mg /l NO2 Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,002 - 20,0) mg /l NO2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,002 - 20,0) mg /l NO2 Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotynowego Zakres: (0,002 - 20,0) mg /l NO2 Metoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotynowego Zakres: (0,002 - 20,0) mg /l NO2 Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Nitrite nitrogen concentration Range: (0,002 - 20,0) mg /l NO2 Spectrophotometric method PN-EN 26777:1999","search_zh":"水、生活饮用水、污水 PN-EN 26777:1999","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff6","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie ortofosforanów Zakres: (0,020 - 60,0) mg/l PO4 Metoda spektrofotometryczna","methodology_en":"Orthophosphate concentration Range: (0,020 - 60,0) mg/l PO4 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów Zakres: (0,020 - 60,0) mg/l PO4 Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ortofosforanów Zakres: (0,020 - 60,0) mg/l PO4 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4 Woda, woda do spozycia przez ludzi, scieki Stezenie ortofosforanow Zakres: (0,020 - 60,0) mg/l PO4 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Orthophosphate concentration Range: (0,020 - 60,0) mg/l PO4 Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4","search_zh":"水、生活饮用水、污水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt. 4","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff7","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chlorków Zakres: (10 - 7000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (10 - 7000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (10 - 7000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków Zakres: (10 - 7000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow Zakres: (10 - 7000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Chloride concentration Range: (10 - 7000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、生活饮用水、污水 PN-ISO 9297:1994","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff8","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie siarczanów Zakres: (10 - 5000) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (10 - 5000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 - 5000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów Zakres: (10 - 5000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow Zakres: (10 - 5000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Sulphate concentration Range: (10 - 5000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水、生活饮用水、污水 PN-ISO 9280:2002","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ff9","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie fluorków Zakres: (0,100 - 100) mg/l Metoda potencjometryczna","methodology_en":"Fluoride concentration Range: (0,100 - 100) mg/l Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,100 - 100) mg/l Metoda potencjometryczna","reference":"PN-78/C-04588.03","norm_bases":["PN-78/C-04588.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fluorków Zakres: (0,100 - 100) mg/l Metoda potencjometryczna PN-78/C-04588.03 Woda, woda do spozycia przez ludzi, scieki Stezenie fluorkow Zakres: (0,100 - 100) mg/l Metoda potencjometryczna PN-78/C-04588.03","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Fluoride concentration Range: (0,100 - 100) mg/l Potentiometric method PN-78/C-04588.03","search_zh":"水、生活饮用水、污水 PN-78/C-04588.03","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ffa","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie żelaza ogólnego Zakres: (0,010 - 10,00) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,010 - 10,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,010 - 10,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie żelaza ogólnego Zakres: (0,010 - 10,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, woda do spozycia przez ludzi, scieki Stezenie zelaza ogolnego Zakres: (0,010 - 10,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Total iron concentration Range: (0,010 - 10,00) mg/l Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06","search_zh":"水、生活饮用水、污水 PN-ISO 6332:2001 + Ap1:2016-06","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ffb","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie boru Zakres: (0,05 - 2,50) mg/l Metoda spektrofotometryczna","methodology_en":"Boron concentration Range: (0,05 - 2,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie boru Zakres: (0,05 - 2,50) mg/l Metoda spektrofotometryczna","reference":"PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE","norm_bases":["PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie boru Zakres: (0,05 - 2,50) mg/l Metoda spektrofotometryczna PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE Woda, woda do spozycia przez ludzi, scieki Stezenie boru Zakres: (0,05 - 2,50) mg/l Metoda spektrofotometryczna PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Boron concentration Range: (0,05 - 2,50) mg/l Spectrophotometric method PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE","search_zh":"水、生活饮用水、污水 PT-7 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu HACH LANGE","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ffc","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO Zakres: (0,30 - 1000) mg/l Metoda spektrometrii w zakresie podczerwieni IR.","methodology_en":"Total organic carbon concentration (TOC Range: (0,30 - 1000) mg/l Infrared range spectrometry method IR.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO Zakres: (0,30 - 1000) mg/l Metoda spektrometrii w zakresie podczerwieni IR.","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ogólnego węgla organicznego (OWO Zakres: (0,30 - 1000) mg/l Metoda spektrometrii w zakresie podczerwieni IR. PN-EN 1484:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie ogolnego wegla organicznego (OWO Zakres: (0,30 - 1000) mg/l Metoda spektrometrii w zakresie podczerwieni IR. PN-EN 1484:1999","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Total organic carbon concentration (TOC Range: (0,30 - 1000) mg/l Infrared range spectrometry method IR. PN-EN 1484:1999","search_zh":"水、生活饮用水、污水 PN-EN 1484:1999","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ffd","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie rtęci Zakres: (0,25 - 5,0) µg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury concentration Range: (0,25 - 5,0) µg/l Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,25 - 5,0) µg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07E","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie rtęci Zakres: (0,25 - 5,0) µg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PN-EN ISO 12846:2012 +Ap1:2016-07E Woda, woda do spozycia przez ludzi, scieki Stezenie rteci Zakres: (0,25 - 5,0) µg/l Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PN-EN ISO 12846:2012 +Ap1:2016-07E","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Mercury concentration Range: (0,25 - 5,0) µg/l Atomic absorption spectrometry with amalgamation technique PN-EN ISO 12846:2012 +Ap1:2016-07E","search_zh":"水、生活饮用水、污水 PN-EN ISO 12846:2012 +Ap1:2016-07E","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252ffe","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX) Zakres: benzen (0,5 - 5000) µg/l etylobenzen (0,5 - 5000) µg/l toluen (0,5 - 5000) µg/l o-ksylen (0,5 - 5000) µg/l m+p-ksylen (1,0 - 10000) µg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","methodology_en":"Monocyclic aromatic hydrocarbons (BTEX) concentration Range: benzene (0,5 - 5000) µg/l ethylbenzene (0,5 - 5000) µg/l toluene (0,5 - 5000) µg/l o-xylene (0,5 - 5000) µg/l m+p-xylene (1,0 - 10000) µg/l Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX) Zakres: benzen (0,5 - 5000) µg/l etylobenzen (0,5 - 5000) µg/l toluen (0,5 - 5000) µg/l o-ksylen (0,5 - 5000) µg/l m+p-ksylen (1,0 - 10000) µg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX) Zakres: benzen (0,5 - 5000) µg/l etylobenzen (0,5 - 5000) µg/l toluen (0,5 - 5000) µg/l o-ksylen (0,5 - 5000) µg/l m+p-ksylen (1,0 - 10000) µg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie jednopierscieniowych weglowodorow aromatycznych (BTEX) Zakres: benzen (0,5 - 5000) µg/l etylobenzen (0,5 - 5000) µg/l toluen (0,5 - 5000) µg/l o-ksylen (0,5 - 5000) µg/l m+p-ksylen (1,0 - 10000) µg/l Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Monocyclic aromatic hydrocarbons (BTEX) concentration Range: benzene (0,5 - 5000) µg/l ethylbenzene (0,5 - 5000) µg/l toluene (0,5 - 5000) µg/l o-xylene (0,5 - 5000) µg/l m+p-xylene (1,0 - 10000) µg/l Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-ISO 11423-1:2002","search_zh":"水、生活饮用水、污水 PN-ISO 11423-1:2002","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38252fff","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Suma BTEX (z obliczeń)","methodology_en":"Sum of BTEX (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Suma BTEX (z obliczeń) Woda, woda do spozycia przez ludzi, scieki Suma BTEX (z obliczen)","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Sum of BTEX (calculated)","search_zh":"水、生活饮用水、污水 BTEX 总量（由计算得出）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"BTEX 总量（由计算得出）"},{"_id":"6a5a55fc9af9f73f38253000","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów Zakres: trichloroeten (1,00 – 200) μg/l tetrachloroeten (1,00 – 200) μg/l tetrachlorometan (1,00 – 200) μg/l 1,2-dichloroetan (1,00 – 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","methodology_en":"Concentration of highly volatile halogenated hydrocarbon derivatives Range: trichloroethene (1,00 – 200) μg/l tetrachloroethene (1,00 – 200) μg/l tetrachloromethane (1,00 – 200) μg/l 1,2-dichloroethane (1,00 – 200) μg/l Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów Zakres: trichloroeten (1,00 – 200) μg/l tetrachloroeten (1,00 – 200) μg/l tetrachlorometan (1,00 – 200) μg/l 1,2-dichloroetan (1,00 – 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów Zakres: trichloroeten (1,00 – 200) μg/l tetrachloroeten (1,00 – 200) μg/l tetrachlorometan (1,00 – 200) μg/l 1,2-dichloroetan (1,00 – 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie latwo lotnych chlorowcowych pochodnych weglowodorow Zakres: trichloroeten (1,00 – 200) μg/l tetrachloroeten (1,00 – 200) μg/l tetrachlorometan (1,00 – 200) μg/l 1,2-dichloroetan (1,00 – 200) μg/l Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Concentration of highly volatile halogenated hydrocarbon derivatives Range: trichloroethene (1,00 – 200) μg/l tetrachloroethene (1,00 – 200) μg/l tetrachloromethane (1,00 – 200) μg/l 1,2-dichloroethane (1,00 – 200) μg/l Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-EN ISO 10301:2002","search_zh":"水、生活饮用水、污水 PN-EN ISO 10301:2002","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38253001","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Suma trichloroetenu i tetrachloroetenu (z obliczeń) Woda, woda do spozycia przez ludzi, scieki Suma trichloroetenu i tetrachloroetenu (z obliczen)","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Sum of trichloroethene and tetrachloroethene (calculated)","search_zh":"水、生活饮用水、污水 三氯乙烯与四氯乙烯总量（由计算得出）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"_id":"6a5a55fc9af9f73f38253002","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie pierwiastków Zakres: antymon (0,004 – 5,00) mg/l arsen (0,002 – 5,00) mg/l bar (0,010 – 5,00) mg/l beryl (0,002 – 5,00) mg/l bor (0,050 – 10,0) mg/l chrom (0,002 – 5,00) mg/l cyna (0,050 – 10,0) mg/l cynk (0,020 – 10,0) mg/l fosfor (0,010 – 50,0) mg/l glin (0,020 – 5,00) mg/l kadm (0,001 – 5,00) mg/l kobalt (0,002 – 5,00) mg/l magnez (0,500 – 500) mg/l mangan (0,010 – 50,0) mg/l miedź (0,010 – 5,00) mg/l molibden (0,002 – 5,00) mg/l nikiel (0,002 – 5,00) mg/l ołów (0,002 – 5,00) mg/l potas (0,300 – 100) mg/l selen (0,002 – 5,00) mg/l sód (0,500 – 100) mg/l srebro (0,002 – 5,00) mg/l stront (0,002 – 10,0) mg/l tal (0,010 – 5,00) mg/l tytan (0,002 – 5,00) mg/l wanad (0,002 – 5,00) mg/l wapń (2,00 – 500) mg/l żelazo (0,010 – 50,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: antimony (0,004 – 5,00) mg/l arsenic (0,002 – 5,00) mg/l barium (0,010 – 5,00) mg/l beryllium (0,002 – 5,00) mg/l boron (0,050 – 10,0) mg/l chromium (0,002 – 5,00) mg/l tin (0,050 – 10,0) mg/l zinc (0,020 – 10,0) mg/l phosphorus (0,010 – 50,0) mg/l aluminium (0,020 – 5,00) mg/l cadmium (0,001 – 5,00) mg/l cobalt (0,002 – 5,00) mg/l magnesium (0,500 – 500) mg/l manganese (0,010 – 50,0) mg/l copper (0,010 – 5,00) mg/l molybdenum (0,002 – 5,00) mg/l nickel (0,002 – 5,00) mg/l lead (0,002 – 5,00) mg/l potassium (0,300 – 100) mg/l selenium (0,002 – 5,00) mg/l sodium (0,500 – 100) mg/l silver (0,002 – 5,00) mg/l strontium (0,002 – 10,0) mg/l thallium (0,010 – 5,00) mg/l titanium (0,002 – 5,00) mg/l vanadium (0,002 – 5,00) mg/l calcium (2,00 – 500) mg/l iron (0,010 – 50,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: antymon (0,004 – 5,00) mg/l arsen (0,002 – 5,00) mg/l bar (0,010 – 5,00) mg/l beryl (0,002 – 5,00) mg/l bor (0,050 – 10,0) mg/l chrom (0,002 – 5,00) mg/l cyna (0,050 – 10,0) mg/l cynk (0,020 – 10,0) mg/l fosfor (0,010 – 50,0) mg/l glin (0,020 – 5,00) mg/l kadm (0,001 – 5,00) mg/l kobalt (0,002 – 5,00) mg/l magnez (0,500 – 500) mg/l mangan (0,010 – 50,0) mg/l miedź (0,010 – 5,00) mg/l molibden (0,002 – 5,00) mg/l nikiel (0,002 – 5,00) mg/l ołów (0,002 – 5,00) mg/l potas (0,300 – 100) mg/l selen (0,002 – 5,00) mg/l sód (0,500 – 100) mg/l srebro (0,002 – 5,00) mg/l stront (0,002 – 10,0) mg/l tal (0,010 – 5,00) mg/l tytan (0,002 – 5,00) mg/l wanad (0,002 – 5,00) mg/l wapń (2,00 – 500) mg/l żelazo (0,010 – 50,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie pierwiastków Zakres: antymon (0,004 – 5,00) mg/l arsen (0,002 – 5,00) mg/l bar (0,010 – 5,00) mg/l beryl (0,002 – 5,00) mg/l bor (0,050 – 10,0) mg/l chrom (0,002 – 5,00) mg/l cyna (0,050 – 10,0) mg/l cynk (0,020 – 10,0) mg/l fosfor (0,010 – 50,0) mg/l glin (0,020 – 5,00) mg/l kadm (0,001 – 5,00) mg/l kobalt (0,002 – 5,00) mg/l magnez (0,500 – 500) mg/l mangan (0,010 – 50,0) mg/l miedź (0,010 – 5,00) mg/l molibden (0,002 – 5,00) mg/l nikiel (0,002 – 5,00) mg/l ołów (0,002 – 5,00) mg/l potas (0,300 – 100) mg/l selen (0,002 – 5,00) mg/l sód (0,500 – 100) mg/l srebro (0,002 – 5,00) mg/l stront (0,002 – 10,0) mg/l tal (0,010 – 5,00) mg/l tytan (0,002 – 5,00) mg/l wanad (0,002 – 5,00) mg/l wapń (2,00 – 500) mg/l żelazo (0,010 – 50,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi, scieki Stezenie pierwiastkow Zakres: antymon (0,004 – 5,00) mg/l arsen (0,002 – 5,00) mg/l bar (0,010 – 5,00) mg/l beryl (0,002 – 5,00) mg/l bor (0,050 – 10,0) mg/l chrom (0,002 – 5,00) mg/l cyna (0,050 – 10,0) mg/l cynk (0,020 – 10,0) mg/l fosfor (0,010 – 50,0) mg/l glin (0,020 – 5,00) mg/l kadm (0,001 – 5,00) mg/l kobalt (0,002 – 5,00) mg/l magnez (0,500 – 500) mg/l mangan (0,010 – 50,0) mg/l miedz (0,010 – 5,00) mg/l molibden (0,002 – 5,00) mg/l nikiel (0,002 – 5,00) mg/l olow (0,002 – 5,00) mg/l potas (0,300 – 100) mg/l selen (0,002 – 5,00) mg/l sod (0,500 – 100) mg/l srebro (0,002 – 5,00) mg/l stront (0,002 – 10,0) mg/l tal (0,010 – 5,00) mg/l tytan (0,002 – 5,00) mg/l wanad (0,002 – 5,00) mg/l wapn (2,00 – 500) mg/l zelazo (0,010 – 50,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Element concentrations Range: antimony (0,004 – 5,00) mg/l arsenic (0,002 – 5,00) mg/l barium (0,010 – 5,00) mg/l beryllium (0,002 – 5,00) mg/l boron (0,050 – 10,0) mg/l chromium (0,002 – 5,00) mg/l tin (0,050 – 10,0) mg/l zinc (0,020 – 10,0) mg/l phosphorus (0,010 – 50,0) mg/l aluminium (0,020 – 5,00) mg/l cadmium (0,001 – 5,00) mg/l cobalt (0,002 – 5,00) mg/l magnesium (0,500 – 500) mg/l manganese (0,010 – 50,0) mg/l copper (0,010 – 5,00) mg/l molybdenum (0,002 – 5,00) mg/l nickel (0,002 – 5,00) mg/l lead (0,002 – 5,00) mg/l potassium (0,300 – 100) mg/l selenium (0,002 – 5,00) mg/l sodium (0,500 – 100) mg/l silver (0,002 – 5,00) mg/l strontium (0,002 – 10,0) mg/l thallium (0,010 – 5,00) mg/l titanium (0,002 – 5,00) mg/l vanadium (0,002 – 5,00) mg/l calcium (2,00 – 500) mg/l iron (0,010 – 50,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、生活饮用水、污水 PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55fc9af9f73f38253003","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie glinu (aluminium) Zakres: (0,050 - 3,00) mg/l Metoda spektrofotometryczna","methodology_en":"Aluminium concentration Range: (0,050 - 3,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie glinu (aluminium) Zakres: (0,050 - 3,00) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04605.02","norm_bases":["PN-92/C-04605.02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie glinu (aluminium) Zakres: (0,050 - 3,00) mg/l Metoda spektrofotometryczna PN-92/C-04605.02 Woda, woda do spozycia przez ludzi Stezenie glinu (aluminium) Zakres: (0,050 - 3,00) mg/l Metoda spektrofotometryczna PN-92/C-04605.02","categories":["water","materials"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Aluminium concentration Range: (0,050 - 3,00) mg/l Spectrophotometric method PN-92/C-04605.02","search_zh":"水、生活饮用水 PN-92/C-04605.02","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253004","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie cyjanków wolnych Zakres: (0,01 - 0,30) mg/l Metoda fotometryczna","methodology_en":"Free cyanide concentration Range: (0,01 - 0,30) mg/l Photometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych Zakres: (0,01 - 0,30) mg/l Metoda fotometryczna","reference":"PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK","norm_bases":["PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie cyjanków wolnych Zakres: (0,01 - 0,30) mg/l Metoda fotometryczna PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK Woda, woda do spozycia przez ludzi Stezenie cyjankow wolnych Zakres: (0,01 - 0,30) mg/l Metoda fotometryczna PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Free cyanide concentration Range: (0,01 - 0,30) mg/l Photometric method PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK","search_zh":"水、生活饮用水 PT-6 wydanie nr 1 z dnia 01.07.2019 r. na podstawie testu MERCK","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253005","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (5 - 100) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 - 100) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 - 100) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (5 - 100) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda, woda do spozycia przez ludzi Barwa Zakres: (5 - 100) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (5 - 100) mg/l Pt Visual method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","search_zh":"水、生活饮用水 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253006","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność Zakres: (0,20 - 1000) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,20 - 1000) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 - 1000) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność Zakres: (0,20 - 1000) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc Zakres: (0,20 - 1000) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Turbidity Range: (0,20 - 1000) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水、生活饮用水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253007","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 - 2000) mg /l CaCO3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5,0 - 2000) mg /l CaCO3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 - 2000) mg /l CaCO3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 - 2000) mg /l CaCO3 Metoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5,0 - 2000) mg /l CaCO3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5,0 - 2000) mg /l CaCO3 Titrimetric method PN-ISO 6059:1999","search_zh":"水、生活饮用水 PN-ISO 6059:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253008","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wolnego ditlenku węgla Zakres: (2,2 - 220) mg/l Metoda miareczkowa","methodology_en":"Free carbon dioxide concentration Range: (2,2 - 220) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wolnego ditlenku węgla Zakres: (2,2 - 220) mg/l Metoda miareczkowa","reference":"PN-74/C-04547.01","norm_bases":["PN-74/C-04547.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wolnego ditlenku węgla Zakres: (2,2 - 220) mg/l Metoda miareczkowa PN-74/C-04547.01 Woda, woda do spozycia przez ludzi Stezenie wolnego ditlenku wegla Zakres: (2,2 - 220) mg/l Metoda miareczkowa PN-74/C-04547.01","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Free carbon dioxide concentration Range: (2,2 - 220) mg/l Titrimetric method PN-74/C-04547.01","search_zh":"水、生活饮用水 PN-74/C-04547.01","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f38253009","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie ditlenku węgla agresywnego (z obliczeń)","methodology_en":"Aggressive carbon dioxide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku węgla agresywnego (z obliczeń)","reference":"PN-74/C-04547.03 pkt. 2.2","norm_bases":["PN-74/C-04547.03 pkt. 2.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ditlenku węgla agresywnego (z obliczeń) PN-74/C-04547.03 pkt. 2.2 Woda, woda do spozycia przez ludzi Stezenie ditlenku wegla agresywnego (z obliczen) PN-74/C-04547.03 pkt. 2.2","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Aggressive carbon dioxide concentration (calculated) PN-74/C-04547.03 pkt. 2.2","search_zh":"水、生活饮用水 PN-74/C-04547.03 pkt. 2.2","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f3825300a","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa smaku (TFN) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony","methodology_en":"Threshold flavour number (TFN) Range: (1 - 8) Simplified and full method, paired, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa smaku (TFN) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa smaku (TFN) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa smaku (TFN) Zakres: (1 - 8) Metoda uproszczona i pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Threshold flavour number (TFN) Range: (1 - 8) Simplified and full method, paired, non-forced choice PN-EN 1622:2006","search_zh":"水、生活饮用水 PN-EN 1622:2006","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f3825300b","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa zapachu (TON) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony","methodology_en":"Threshold odour number (TON) Range: (1 - 8) Simplified and full method, paired, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu (TON) Zakres: (1 - 8) Metoda uproszczona i pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu (TON) Zakres: (1 - 8) Metoda uproszczona i pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Threshold odour number (TON) Range: (1 - 8) Simplified and full method, paired, non-forced choice PN-EN 1622:2006","search_zh":"水、生活饮用水 PN-EN 1622:2006","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f3825300c","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie ozonu Zakres: (0,01 - 1,50) mg/l Metoda spektrofotometryczna","methodology_en":"Ozone concentration Range: (0,01 - 1,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ozonu Zakres: (0,01 - 1,50) mg/l Metoda spektrofotometryczna","reference":"PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls","norm_bases":["PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ozonu Zakres: (0,01 - 1,50) mg/l Metoda spektrofotometryczna PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls Woda, woda do spozycia przez ludzi Stezenie ozonu Zakres: (0,01 - 1,50) mg/l Metoda spektrofotometryczna PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ozone concentration Range: (0,01 - 1,50) mg/l Spectrophotometric method PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls","search_zh":"水、生活饮用水 PT-12 wydanie nr 1 z dnia 04.05.2020 r. na podstawie testu HACH nr 8311 AccuVac Ampuls","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f3825300d","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie trihalogenometanów (THM) Zakres: trichlorometan (chloroform) (1,00 - 200) μg/l bromodichlorometan (1,00 - 200) μg/l dibromochlorometan (1,00 - 200) μg/l tribromometan (bromoform) (1,00 - 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrii mas (HS-GC-MS)","methodology_en":"Trihalomethane (THM) concentration Range: trichloromethane (chloroform) (1,00 - 200) μg/l bromodichloromethane (1,00 - 200) μg/l dibromochloromethane (1,00 - 200) μg/l tribromomethane (bromoform) (1,00 - 200) μg/l Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie trihalogenometanów (THM) Zakres: trichlorometan (chloroform) (1,00 - 200) μg/l bromodichlorometan (1,00 - 200) μg/l dibromochlorometan (1,00 - 200) μg/l tribromometan (bromoform) (1,00 - 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrii mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie trihalogenometanów (THM) Zakres: trichlorometan (chloroform) (1,00 - 200) μg/l bromodichlorometan (1,00 - 200) μg/l dibromochlorometan (1,00 - 200) μg/l tribromometan (bromoform) (1,00 - 200) μg/l Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrii mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda, woda do spozycia przez ludzi Stezenie trihalogenometanow (THM) Zakres: trichlorometan (chloroform) (1,00 - 200) μg/l bromodichlorometan (1,00 - 200) μg/l dibromochlorometan (1,00 - 200) μg/l tribromometan (bromoform) (1,00 - 200) μg/l Metoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometrii mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Trihalomethane (THM) concentration Range: trichloromethane (chloroform) (1,00 - 200) μg/l bromodichloromethane (1,00 - 200) μg/l dibromochloromethane (1,00 - 200) μg/l tribromomethane (bromoform) (1,00 - 200) μg/l Gas chromatography method with headspace analysis and mass spectrometry detection (HS-GC-MS) PN-EN ISO 10301:2002","search_zh":"水、生活饮用水 PN-EN ISO 10301:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fc9af9f73f3825300e","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma THM (z obliczeń)","methodology_en":"Sum of THM (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma THM (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma THM (z obliczeń) Woda, woda do spozycia przez ludzi Suma THM (z obliczen)","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sum of THM (calculated)","search_zh":"水、生活饮用水 三卤甲烷总量（由计算得出）","test_object_zh":"水、生活饮用水","methodology_zh":"三卤甲烷总量（由计算得出）"},{"_id":"6a5a55fc9af9f73f3825300f","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Twardość węglanowa (z obliczeń)","methodology_en":"Carbonate hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość węglanowa (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Twardość węglanowa (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 Woda Twardosc weglanowa (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2","search_zh":"水 碳酸盐硬度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2","test_object_zh":"水","methodology_zh":"碳酸盐硬度（由计算得出）"},{"_id":"6a5a55fc9af9f73f38253010","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Twardość niewęglanowa (z obliczeń)","methodology_en":"Non-carbonate hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość niewęglanowa (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Twardość niewęglanowa (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999 Woda Twardosc nieweglanowa (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Non-carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999","search_zh":"水 非碳酸盐硬度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004 pkt. 8.2 PN-ISO 6059:1999","test_object_zh":"水","methodology_zh":"非碳酸盐硬度（由计算得出）"},{"_id":"6a5a55fc9af9f73f38253011","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,50 - 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C","reference":"PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,50 - 50) °C PN-EN ISO 5667-6:2016-12 z wyl. pkt. 7.2 | PN-77/C-04584","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,50 - 50) °C PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2 | PN-77/C-04584","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a55fc9af9f73f38253012","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C Poziom lustra wody Zakres: (0,1 - 50) m.p.p.t.","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,50 - 50) °C Water table level Range: (0,1 - 50) m below ground level","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C Poziom lustra wody Zakres: (0,1 - 50) m.p.p.t.","reference":"PN-ISO 5667-11:2017-10 z wył. pkt. 5.2 | PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r.","norm_bases":["PN-ISO 5667-11:2017-10 z wył. pkt. 5.2","PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C Poziom lustra wody Zakres: (0,1 - 50) m.p.p.t. PN-ISO 5667-11:2017-10 z wył. pkt. 5.2 | PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r. Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,50 - 50) °C Poziom lustra wody Zakres: (0,1 - 50) m.p.p.t. PN-ISO 5667-11:2017-10 z wyl. pkt. 5.2 | PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r.","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,50 - 50) °C Water table level Range: (0,1 - 50) m below ground level PN-ISO 5667-11:2017-10 z wył. pkt. 5.2 | PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r.","search_zh":"水 PN-ISO 5667-11:2017-10 z wył. pkt. 5.2 | PN-77/C-04584 PT-16 wydanie 2 z dnia 08.10.2021 r.","test_object_zh":"水"},{"_id":"6a5a55fc9af9f73f38253013","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,50 - 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C","reference":"PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,50 - 50) °C PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,50 - 50) °C PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,50 - 50) °C PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10+Ap1:2019-07 PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a5a55fc9af9f73f38253014","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (0,50 - 70) °C","methodology_en":"Sampling for microbiological testing Temperature of the water sample taken Range: (0,50 - 70) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (0,50 - 70) °C","reference":"PN-EN ISO 19458:2007 PN-77/C-04584","norm_bases":["PN-EN ISO 19458:2007 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (0,50 - 70) °C PN-EN ISO 19458:2007 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych Temperatura pobranej probki wody Zakres: (0,50 - 70) °C PN-EN ISO 19458:2007 PN-77/C-04584","categories":["water","microbiology"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing Temperature of the water sample taken Range: (0,50 - 70) °C PN-EN ISO 19458:2007 PN-77/C-04584","search_zh":"生活饮用水 PN-EN ISO 19458:2007 PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a5a55fc9af9f73f38253015","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny łatwo opadające Zakres: (0,2 - 100) ml/l Metoda objętościowa","methodology_en":"Settleable solids Range: (0,2 - 100) ml/l Volumetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny łatwo opadające Zakres: (0,2 - 100) ml/l Metoda objętościowa","reference":"PN-72/C-04559.03","norm_bases":["PN-72/C-04559.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny łatwo opadające Zakres: (0,2 - 100) ml/l Metoda objętościowa PN-72/C-04559.03 Scieki Zawiesiny latwo opadajace Zakres: (0,2 - 100) ml/l Metoda objetosciowa PN-72/C-04559.03","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Settleable solids Range: (0,2 - 100) ml/l Volumetric method PN-72/C-04559.03","search_zh":"污水 PN-72/C-04559.03","test_object_zh":"污水"},{"_id":"6a5a55fc9af9f73f38253016","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe","test_object_en":"Wastewater, rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (0,50 - 50) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (0,50 - 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (0,50 - 50) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (0,50 - 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki, wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej probki sciekow Zakres: (0,50 - 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (0,50 - 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水、雨水、融雪水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水、雨水、融雪水"},{"_id":"6a5a55fc9af9f73f38253017","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997","norm_bases":["PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997","categories":["environment"],"row_index":77,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 PN-ISO 10381-5:2009 PN-R-04031:1997","test_object_zh":"土壤"},{"_id":"6a5a55fc9af9f73f38253018","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","test_object_en":"Sewage sludge Waste O) code: 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","methodology_en":"Sampling for chemical, physical and microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011 p. 6.3.6","norm_bases":["PN-EN ISO 5667-13:2011 p. 6.3.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011 p. 6.3.6 Osady sciekowe Odpady O) kod: 19 08 05 Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011 p. 6.3.6","categories":["water","environment","microbiology"],"row_index":78,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Waste O) code: 19 08 05 Sampling for chemical, physical and microbiological testing PN-EN ISO 5667-13:2011 p. 6.3.6","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"用于化学、物理与微生物检验的采样 PN-EN ISO 5667-13:2011 p. 6.3.6"},{"_id":"6a5a55fc9af9f73f38253019","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 01, 19 08 02, 19 02 99","test_object_en":"Waste O) code: 19 08 01, 19 08 02, 19 02 99","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","methodology_en":"Sampling for chemical, physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"PN-EN ISO 5667-13:2011 p. 6.3.6","norm_bases":["PN-EN ISO 5667-13:2011 p. 6.3.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 19 08 01, 19 08 02, 19 02 99 Pobieranie próbek do badań chemicznych, fizycznych PN-EN ISO 5667-13:2011 p. 6.3.6 Odpady O) kod: 19 08 01, 19 08 02, 19 02 99 Pobieranie probek do badan chemicznych, fizycznych PN-EN ISO 5667-13:2011 p. 6.3.6","categories":["environment"],"row_index":79,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 19 08 01, 19 08 02, 19 02 99 Sampling for chemical, physical testing PN-EN ISO 5667-13:2011 p. 6.3.6","methodology_zh":"用于化学、物理检验的采样","search_zh":"用于化学、物理检验的采样 PN-EN ISO 5667-13:2011 p. 6.3.6"},{"_id":"6a5a55fc9af9f73f3825301a","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":80,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"饮用水"},{"_id":"6a5a55fc9af9f73f3825301b","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba Escherichia coli Metoda filtracji membranowej Woda do spozycia Liczba Escherichia coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":81,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Escherichia coli count Membrane filtration method","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法","test_object_zh":"饮用水"},{"_id":"6a5a55fc9af9f73f3825301c","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba Enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba Enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia Liczba Enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数 膜过滤法","search_zh":"饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"饮用水"},{"_id":"6a5a55fc9af9f73f3825301d","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total microorganism count at 36 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Ogólna liczba mikroorganizmów w temp. 36 °C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia Ogolna liczba mikroorganizmow w temp. 36 °C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"饮用水 36 °C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"饮用水","methodology_zh":"36 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fc9af9f73f3825301e","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total microorganism count at 22 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C Metoda płytkowa (posiew wgłębny)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Ogólna liczba mikroorganizmów w temp. 22 °C Metoda płytkowa (posiew wgłębny) Woda do spozycia Ogolna liczba mikroorganizmow w temp. 22 °C Metoda plytkowa (posiew wglebny)","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Total microorganism count at 22 °C Plate method (pour plate)","search_zh":"饮用水 22 °C 微生物总数 平板法（倾注平板）","test_object_zh":"饮用水","methodology_zh":"22 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fc9af9f73f3825301f","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba Clostridium perfringers, łącznie ze sporami Metoda filtracji membranowej","methodology_en":"Clostridium perfringers count, including spores Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringers, łącznie ze sporami Metoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba Clostridium perfringers, łącznie ze sporami Metoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia Liczba Clostridium perfringers, lacznie ze sporami Metoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Clostridium perfringers count, including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"饮用水 PN-EN ISO 14189:2016-10","test_object_zh":"饮用水"},{"_id":"6a5a55fc9af9f73f38253020","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Metoda filtracji membranowej","methodology_en":"Count of bacteria of the genus Legionella Matrix A: Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Metoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (pozywka BCYE) Procedura 7 (pozywka GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":86,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Drinking water Count of bacteria of the genus Legionella Matrix A: Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"饮用水 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"饮用水"},{"_id":"6a5a55fc9af9f73f38253021","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Wyroby tytoniowe: - włókna roślinne nasączone roztworem nikotyny (mieszanka OND)","test_object_en":"Tobacco products: - plant fibres impregnated with nicotine solution (OND mixture)","methodology":"Zawartość nikotyny Zakres: (0,024 - 38,4) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Nicotine content Range: (0,024 - 38,4) mg/g Gas chromatography method with flame ionization detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość nikotyny Zakres: (0,024 - 38,4) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ended Method No. 62 2021-12","norm_bases":["ended Method No. 62 2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: - włókna roślinne nasączone roztworem nikotyny (mieszanka OND) Zawartość nikotyny Zakres: (0,024 - 38,4) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ended Method No. 62 2021-12 Wyroby tytoniowe: - wlokna roslinne nasaczone roztworem nikotyny (mieszanka OND) Zawartosc nikotyny Zakres: (0,024 - 38,4) mg/g Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ended Method No. 62 2021-12","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tobacco products: - plant fibres impregnated with nicotine solution (OND mixture) Nicotine content Range: (0,024 - 38,4) mg/g Gas chromatography method with flame ionization detection (GC-FID) ended Method No. 62 2021-12"},{"_id":"6a5a55fc9af9f73f38253022","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Wyroby tytoniowe: - włókna roślinne nasączone roztworem nikotyny (mieszanka OND)","test_object_en":"Tobacco products: - plant fibres impregnated with nicotine solution (OND mixture)","methodology":"Stężenie glikolu 1,2-propylenowego, glicerolu Zakres: (0,3 - 5,0) % Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Concentration of 1,2-propylene glycol, glycerol Range: (0,3 - 5,0) % Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie glikolu 1,2-propylenowego, glicerolu Zakres: (0,3 - 5,0) % Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ended Method No. 60 2019-06","norm_bases":["ended Method No. 60 2019-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: - włókna roślinne nasączone roztworem nikotyny (mieszanka OND) Stężenie glikolu 1,2-propylenowego, glicerolu Zakres: (0,3 - 5,0) % Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ended Method No. 60 2019-06 Wyroby tytoniowe: - wlokna roslinne nasaczone roztworem nikotyny (mieszanka OND) Stezenie glikolu 1,2-propylenowego, glicerolu Zakres: (0,3 - 5,0) % Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ended Method No. 60 2019-06","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tobacco products: - plant fibres impregnated with nicotine solution (OND mixture) Concentration of 1,2-propylene glycol, glycerol Range: (0,3 - 5,0) % Gas chromatography with flame ionisation detection (GC-FID) ended Method No. 60 2019-06"},{"_id":"6a5a55fc9af9f73f38253023","lab_id":"69ad52a3de79e566650fb7ba","country":"PL","accr_number":"AB 1488","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","methodology":"Stężenie związków organicznych Zakres: nikotyna (2 - 40) mg/ml nikotyna (0,5 - 200) mg/g glicerol (100 - 1000) mg/ml glicerol (100 - 1000) mg/g glikol propylenowy (100 – 1000) mg/ml glikol propylenowy (100 – 1000) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Concentration of organic compounds Range: nicotine (2 - 40) mg/ml nicotine (0,5 - 200) mg/g glycerol (100 - 1000) mg/ml glycerol (100 - 1000) mg/g propylene glycol (100 – 1000) mg/ml propylene glycol (100 – 1000) mg/g Gas chromatography method with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie związków organicznych Zakres: nikotyna (2 - 40) mg/ml nikotyna (0,5 - 200) mg/g glicerol (100 - 1000) mg/ml glicerol (100 - 1000) mg/g glikol propylenowy (100 – 1000) mg/ml glikol propylenowy (100 – 1000) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ISO 20714:2019 PN-EN ISO 20714:2022-05","norm_bases":["ISO 20714:2019 PN-EN ISO 20714:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Stężenie związków organicznych Zakres: nikotyna (2 - 40) mg/ml nikotyna (0,5 - 200) mg/g glicerol (100 - 1000) mg/ml glicerol (100 - 1000) mg/g glikol propylenowy (100 – 1000) mg/ml glikol propylenowy (100 – 1000) mg/g Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ISO 20714:2019 PN-EN ISO 20714:2022-05 Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Stezenie zwiazkow organicznych Zakres: nikotyna (2 - 40) mg/ml nikotyna (0,5 - 200) mg/g glicerol (100 - 1000) mg/ml glicerol (100 - 1000) mg/g glikol propylenowy (100 – 1000) mg/ml glikol propylenowy (100 – 1000) mg/g Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ISO 20714:2019 PN-EN ISO 20714:2022-05","categories":["electronics"],"row_index":89,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Tobacco products: nicotine liquid for electronic cigarettes Concentration of organic compounds Range: nicotine (2 - 40) mg/ml nicotine (0,5 - 200) mg/g glycerol (100 - 1000) mg/ml glycerol (100 - 1000) mg/g propylene glycol (100 – 1000) mg/ml propylene glycol (100 – 1000) mg/g Gas chromatography method with flame ionisation detection (GC-FID) ISO 20714:2019 PN-EN ISO 20714:2022-05","search_zh":"烟草制品：电子烟用尼古丁液 ISO 20714:2019 PN-EN ISO 20714:2022-05","test_object_zh":"烟草制品：电子烟用尼古丁液"}],"has_pdf":true}