{"lab":{"_id":"69ad52a3de79e566650fb77a","accr_number":"AB 1448","country":"PL","accr_body":"PCA","address":"DZIAŁ LABORATORYJNY, ul. Wierzbowa 52, 90-133 Łódź","categories":["water","microbiology","materials"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":135,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1448.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji sp. z o.o. dział laboratoryjny, ul. wierzbowa 52, 90-133 łódź water other pharma electronics microbiology automotive environment materials food","status":"active","updated_at":"2026-03-08T14:50:36.382Z","valid_from":"","valid_until":"26.08.2029","website":"","parsed_at":"2026-08-17T10:43:40.840Z","email_confidence":"high","email_mx":true,"email_source":"https://zwik.lodz.pl/pl/artykuly/229/badanie-wody","parse_date":"2026-08-17T10:43:40.840Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"N/28/P, N/29/P, N/30/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"Q/28","pl":"Badania sensoryczne wody","en":"Sensory tests of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"15","date":"31.07.2026"},"map_coord":[51.769374,19.47972],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","address":"ul. Wierzbowa 52","city":null,"postal":null},{"name":"DZIAŁ LABORATORYJNY","address":"ul. Wierzbowa 52","city":null,"postal":null},{"name":"Laboratorium Badania Wody","address":"ul. Graniczna 54, 93-428 Łódź","city":"Łódź","postal":"93-428"},{"name":"Laboratorium Ochrony Środowiska","address":"ul. Wierzbowa 52, 90-133 Łódź","city":"Łódź","postal":"90-133"},{"name":"Laboratorium Badania Ścieków","address":"ul. Sanitariuszek 70/72, 93-469 Łódź","city":"Łódź","postal":"93-469"},{"name":"Laboratorium Pobierania Próbek i Badań Terenowych","address":"ul. Sanitariuszek 70/72, 93-469 Łódź","city":"Łódź","postal":"93-469"},{"name":"Laboratorium Badania Wody – Oddział Tomaszów","address":"ul. Jana Pawła II 45/47, 97-200 Tomaszów Mazowiecki","city":"Tomaszów Mazowiecki","postal":"97-200"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/c95e1bf0391a2d7d14693f00e5eb2fb3/AB%201448.pdf","has_en":true,"category_counts":{"water":135,"microbiology":10,"materials":10,"petro":1},"category_scores":{"water":116.83,"microbiology":0.64,"materials":0.64,"petro":0.01},"has_zh":true,"lab_locations_zh":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","address":"ul. Wierzbowa 52","city":null,"postal":null},{"name":"DZIAŁ LABORATORYJNY","address":"ul. Wierzbowa 52","city":null,"postal":null},{"name":"水检测实验室","address":"ul. Graniczna 54, 93-428 Łódź","city":"Łódź","postal":"93-428"},{"name":"环境保护实验室","address":"ul. Wierzbowa 52, 90-133 Łódź","city":"Łódź","postal":"90-133"},{"name":"废水检测实验室","address":"ul. Sanitariuszek 70/72, 93-469 Łódź","city":"Łódź","postal":"93-469"},{"name":"Laboratorium Pobierania Próbek i Badań Terenowych","address":"ul. Sanitariuszek 70/72, 93-469 Łódź","city":"Łódź","postal":"93-469"},{"name":"Laboratorium Badania Wody – Oddział Tomaszów","address":"ul. Jana Pawła II 45/47, 97-200 Tomaszów Mazowiecki","city":"Tomaszów Mazowiecki","postal":"97-200"}]},"methods":[{"_id":"6a82e5dd884ede9a1b2c3f3e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie lotnych związków organicznych","parameters":[{"name":"benzen","range":"(0,10 – 5,0) µg/l"},{"name":"bromodichlorometan","range":"(0,10 – 50,0) µg/l"},{"name":"chlorek winylu","range":"(0,10 – 5,0) µg/l"},{"name":"chlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"dibromochlorometan","range":"0,10 – 50,0) µg/l"},{"name":"tribromometan","range":"(0,10 – 50,0) µg/l"},{"name":"trichlorometan (chloroform)","range":"(0,10 – 50,0) µg/l"},{"name":"trichloroeten","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachloroeten","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-dichloroetan","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"etylobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"o-ksylen","range":"(0,10 – 5,0) µg/l"},{"name":"m+p ksylen","range":"(0,20 –10,0) µg/l"},{"name":"toluen","range":"(0,10 – 5,0) µg/l"},{"name":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)"},{"name":"Suma THM (z obliczeń)"},{"name":"Suma trichlorobenzenów (z obliczeń)"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Suma ksylenów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek węgla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nSuma THM (z obliczeń)\nSuma trichlorobenzenów (z obliczeń)\nSuma metaksylenu i paraksylenu (z obliczeń)\nSuma ksylenów (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek węgla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nSuma THM (z obliczeń)\nSuma trichlorobenzenów (z obliczeń)\nSuma metaksylenu i paraksylenu (z obliczeń)\nSuma ksylenów (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Stezenie lotnych zwiazkow organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek wegla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczen)\nSuma THM (z obliczen)\nSuma trichlorobenzenow (z obliczen)\nSuma metaksylenu i paraksylenu (z obliczen)\nSuma ksylenow (z obliczen)\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Concentration of volatile organic compounds","parameters_en":[{"name":"benzene","range":"(0,10 – 5,0) µg/l"},{"name":"bromodichloromethane","range":"(0,10 – 50,0) µg/l"},{"name":"vinyl chloride","range":"(0,10 – 5,0) µg/l"},{"name":"chlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"dibromochloromethane","range":"0,10 – 50,0) µg/l"},{"name":"tribromomethane","range":"(0,10 – 50,0) µg/l"},{"name":"trichloromethane (chloroform)","range":"(0,10 – 50,0) µg/l"},{"name":"trichloroethene","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachloroethene","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-dichloroethane","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"ethylbenzene","range":"(0,10 – 5,0) µg/l"},{"name":"o-xylene","range":"(0,10 – 5,0) µg/l"},{"name":"m+p xylene","range":"(0,20 –10,0) µg/l"},{"name":"toluene","range":"(0,10 – 5,0) µg/l"},{"name":"Sum of trichloroethene and tetrachloroethene (calculated)"},{"name":"Sum of THM (calculated)"},{"name":"Sum of trichlorobenzenes (calculated)"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Sum of xylenes (calculated)"}],"search_en":"Water intended for human consumption Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Water Testing Laboratory benzene bromodichloromethane vinyl chloride chlorobenzene dibromochloromethane tribromomethane trichloromethane (chloroform) trichloroethene tetrachloroethene 1,2-dichloroethane 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene ethylbenzene o-xylene m+p xylene toluene Sum of trichloroethene and tetrachloroethene (calculated) Sum of THM (calculated) Sum of trichlorobenzenes (calculated) Sum of xylenes (calculated) PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 挥发性有机物浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 水检测实验室 苯 一溴二氯甲烷 氯乙烯 氯苯 二溴一氯甲烷 三溴甲烷 三氯甲烷（氯仿） 三氯乙烯 四氯乙烯 1,2-二氯乙烷 1,2,3-三氯苯 1,2,4-三氯苯 乙苯 邻二甲苯 甲苯 三氯乙烯与四氯乙烯总量（由计算得出） 三卤甲烷总量（由计算得出） 三氯苯总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"生活饮用水","parameters_zh":[{"name":"苯","range":"(0,10 – 5,0) µg/l"},{"name":"一溴二氯甲烷","range":"(0,10 – 50,0) µg/l"},{"name":"氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"二溴一氯甲烷","range":"0,10 – 50,0) µg/l"},{"name":"三溴甲烷","range":"(0,10 – 50,0) µg/l"},{"name":"三氯甲烷（氯仿）","range":"(0,10 – 50,0) µg/l"},{"name":"三氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"四氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-二氯乙烷","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-三氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-三氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"乙苯","range":"(0,10 – 5,0) µg/l"},{"name":"邻二甲苯","range":"(0,10 – 5,0) µg/l"},{"name":"m+p ksylen","range":"(0,20 –10,0) µg/l"},{"name":"甲苯","range":"(0,10 – 5,0) µg/l"},{"name":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"name":"三卤甲烷总量（由计算得出）"},{"name":"三氯苯总量（由计算得出）"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Suma ksylenów (z obliczeń)"}],"lab_section_zh":"水检测实验室","methodology_zh":"挥发性有机物浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a82e5dd884ede9a1b2c3f3f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Water Testing Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 水检测实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f40","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1 – 8"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1 – 8\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 8\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 8\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1 – 8"}],"search_en":"Water intended for human consumption Taste threshold number TFN Full paired method, non-forced choice Water Testing Laboratory Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 8"}],"search_zh":"生活饮用水 味阈值 TFN 完全法、成对法、非强制选择 水检测实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值 TFN","lab_section_zh":"水检测实验室","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82e5dd884ede9a1b2c3f41","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water, water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Water Testing Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 水检测实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f42","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1 – 16"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1 – 16\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 16\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 16\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1 – 16"}],"search_en":"Water, water intended for human consumption Odour threshold number TON Full paired method, non-forced choice Water Testing Laboratory Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 16"}],"search_zh":"水、生活饮用水 嗅阈值 TON 完全法、成对法、非强制选择 水检测实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值 TON","lab_section_zh":"水检测实验室","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82e5dd884ede9a1b2c3f43","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 − 1,29) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 − 1,29) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,06 − 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,06 − 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 − 1,29) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Water Testing Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 − 1,29) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 水检测实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f44","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,040 − 0,820) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,040 − 0,820) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,040 − 0,820) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,040 − 0,820) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,040 − 0,820) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Water Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,040 − 0,820) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 水检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f45","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Free chlorine concentration Colorimetric method Water Testing Laboratory Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 比色法 水检测实验室 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f46","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru ogólnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru ogolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Total chlorine concentration Colorimetric method Water Testing Laboratory Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 总氯浓度 比色法 水检测实验室 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水","methodology_zh":"总氯浓度","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f47","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru związanego (chloraminy) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (chloraminy) (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru związanego (chloraminy) (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru zwiazanego (chloraminy) (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","search_en":"Water, water intended for human consumption Water Testing Laboratory PN-EN ISO 7393-2:2018-04","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 水检测实验室 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f48","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 − 5000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna","reference":"PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","norm_bases":["PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 − 5000) µg/l"}],"search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Water Testing Laboratory Range PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 − 5000) µg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 水检测实验室 范围 PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f49","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(5 − 200) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (5 − 200) µg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01 z wyłączeniem pkt 7a i 7b","norm_bases":["PN-80/C-04603/01 z wyłączeniem pkt 7a i 7b"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie cyjanków ogólnych\nZakres (5 − 200) µg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wyłączeniem pkt 7a i 7b Woda, woda do spozycia przez ludzi Stezenie cyjankow ogolnych\nZakres (5 − 200) µg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wylaczeniem pkt 7a i 7b","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(5 − 200) µg/l"}],"search_en":"Water, water intended for human consumption Total cyanide concentration Spectrophotometric method Water Testing Laboratory Range PN-80/C-04603/01 z wyłączeniem pkt 7a i 7b","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5 − 200) µg/l"}],"search_zh":"水、生活饮用水 总氰化物浓度 分光光度法 水检测实验室 范围 PN-80/C-04603/01 z wyłączeniem pkt 7a i 7b","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"总氰化物浓度"},{"_id":"6a82e5dd884ede9a1b2c3f4a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 − 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda D","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 − 40) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Visual method Water Testing Laboratory Range PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 40) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 水检测实验室 范围 PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f4b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 4,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 4,0) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Water Testing Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 4,0) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水检测实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f4c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 − 10,0"}],"search_en":"Water, water intended for human consumption pH Potentiometric method Water Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 − 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f4d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(150 – 1410) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (150 – 1410) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (150 – 1410) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (150 – 1410) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(150 – 1410) µS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Water Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(150 – 1410) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f4e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,00 − 10,00) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 − 10,00) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 − 10,00) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,00 − 10,00) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,00 − 10,00) mg/l"}],"search_en":"Water, water intended for human consumption Total organic carbon concentration (TOC) High-temperature combustion with IR detection Water Testing Laboratory Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,00 − 10,00) mg/l"}],"search_zh":"水、生活饮用水 总有机碳浓度（TOC） 高温燃烧红外检测法 水检测实验室 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、生活饮用水","methodology_zh":"总有机碳浓度（TOC）","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f4f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 − 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 − 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 − 500) mg/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczne stezenie wapnia i magnezu (twardosc ogolna)\nZakres (5,0 − 500) mg/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total concentration of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 − 500) mg/l"}],"search_en":"Water, water intended for human consumption Total concentration of calcium and magnesium (total hardness) Titrimetric method Water Testing Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,0 − 500) mg/l"}],"search_zh":"水、生活饮用水 钙与镁的总浓度（总硬度） 滴定法 水检测实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"钙与镁的总浓度（总硬度）"},{"_id":"6a82e5dd884ede9a1b2c3f50","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(4,0 – 150,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (4,0 – 150,0) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (4,0 – 150,0) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (4,0 – 150,0) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(4,0 – 150,0) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Water Testing Laboratory Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(4,0 – 150,0) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 水检测实验室 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f51","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C/04554-4:1999 zał. A","norm_bases":["PN-C/04554-4:1999 zał. A"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C/04554-4:1999 zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C/04554-4:1999 zal. A","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) Water Testing Laboratory PN-C/04554-4:1999 zał. A","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） 水检测实验室 PN-C/04554-4:1999 zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f52","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 − 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 − 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 − 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 − 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 − 10,0) mg/l"}],"search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Water Testing Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 − 10,0) mg/l"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 水检测实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f53","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(20 − 300) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (20 − 300) µg/l\nMetoda spektrofotometryczna","reference":"PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","norm_bases":["PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie glinu\nZakres (20 − 300) µg/l\nMetoda spektrofotometryczna PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301 Woda, woda do spozycia przez ludzi Stezenie glinu\nZakres (20 − 300) µg/l\nMetoda spektrofotometryczna PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(20 − 300) µg/l"}],"search_en":"Water, water intended for human consumption Aluminium concentration Spectrophotometric method Water Testing Laboratory Range PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(20 − 300) µg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 水检测实验室 范围 PB-31 wydanie 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f54","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(6 − 1500) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (6 − 1500) µg/l\nMetoda spektrofotometryczna","reference":"PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","norm_bases":["PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (6 − 1500) µg/l\nMetoda spektrofotometryczna PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (6 − 1500) µg/l\nMetoda spektrofotometryczna PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(6 − 1500) µg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Water Testing Laboratory Range PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(6 − 1500) µg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 水检测实验室 范围 PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f55","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie boru","parameters":[{"name":"Zakres","range":"(0,05 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie boru\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307","norm_bases":["PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie boru\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307 Woda, woda do spozycia przez ludzi Stezenie boru\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Boron concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,5) mg/l"}],"search_en":"Water, water intended for human consumption Boron concentration Spectrophotometric method Water Testing Laboratory Range PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 1,5) mg/l"}],"search_zh":"水、生活饮用水 硼浓度 分光光度法 水检测实验室 范围 PB-42 wyd. 02 z dnia 03.01.2022 r. na podstawie testu kuwetowego HACH Nr LCK 307","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"硼浓度"},{"_id":"6a82e5dd884ede9a1b2c3f56","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(1,00 − 10,00) µg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)"],"computed":[],"activity":"Stężenie bromianów\nZakres (1,00 − 10,00) µg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromianów\nZakres (1,00 − 10,00) µg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis) PN-EN ISO 11206:2013-07 Woda, woda do spozycia przez ludzi Stezenie bromianow\nZakres (1,00 − 10,00) µg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/Vis) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(1,00 − 10,00) µg/l"}],"search_en":"Water, water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/Vis) Water Testing Laboratory Range PN-EN ISO 11206:2013-07","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/Vis)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,00 − 10,00) µg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/Vis） 水检测实验室 范围 PN-EN ISO 11206:2013-07","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/Vis）"},{"_id":"6a82e5dd884ede9a1b2c3f57","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"chlorany","range":"(0,025 − 0,700) mg/l"},{"name":"chloryny","range":"(0,025 − 0,700) mg/l"},{"name":"Suma chlorynów i chloranów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorany (0,025 − 0,700) mg/l\nchloryny (0,025 − 0,700) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchlorany (0,025 − 0,700) mg/l\nchloryny (0,025 − 0,700) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchlorany (0,025 − 0,700) mg/l\nchloryny (0,025 − 0,700) mg/l\nSuma chlorynow i chloranow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorates","range":"(0,025 − 0,700) mg/l"},{"name":"chlorites","range":"(0,025 − 0,700) mg/l"},{"name":"Sum of chlorites and chlorates (calculated)"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Water Testing Laboratory chlorates chlorites Sum of chlorites and chlorates (calculated) PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 水检测实验室 氯酸盐 亚氯酸盐 亚氯酸盐与氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","parameters_zh":[{"name":"氯酸盐","range":"(0,025 − 0,700) mg/l"},{"name":"亚氯酸盐","range":"(0,025 − 0,700) mg/l"},{"name":"亚氯酸盐与氯酸盐总量（由计算得出）"}]},{"_id":"6a82e5dd884ede9a1b2c3f58","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"azotany","range":"(0,50 – 50,00) mg/l"},{"name":"chlorki","range":"(2,00 – 90,00) mg/l"},{"name":"siarczany","range":"(2,00 – 150,00) mg/l"},{"name":"fluorki","range":"(0,10 – 1,60) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotany (0,50 – 50,00) mg/l\nchlorki (2,00 – 90,00) mg/l\nsiarczany (2,00 – 150,00) mg/l\nfluorki (0,10 – 1,60) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nazotany (0,50 – 50,00) mg/l\nchlorki (2,00 – 90,00) mg/l\nsiarczany (2,00 – 150,00) mg/l\nfluorki (0,10 – 1,60) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nazotany (0,50 – 50,00) mg/l\nchlorki (2,00 – 90,00) mg/l\nsiarczany (2,00 – 150,00) mg/l\nfluorki (0,10 – 1,60) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrates","range":"(0,50 – 50,00) mg/l"},{"name":"chlorides","range":"(2,00 – 90,00) mg/l"},{"name":"sulfates","range":"(2,00 – 150,00) mg/l"},{"name":"fluorides","range":"(0,10 – 1,60) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Water Testing Laboratory nitrates chlorides sulfates fluorides PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 水检测实验室 硝酸盐 氯化物 硫酸盐 氟化物 PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"硝酸盐","range":"(0,50 – 50,00) mg/l"},{"name":"氯化物","range":"(2,00 – 90,00) mg/l"},{"name":"硫酸盐","range":"(2,00 – 150,00) mg/l"},{"name":"氟化物","range":"(0,10 – 1,60) mg/l"}],"lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f59","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA):","parameters":[{"name":"Benzo(b)fluoranten"},{"name":"Benzo(k)fluoranten"},{"name":"Benzo(a)piren"},{"name":"Benzo(g,h,i)perylen"},{"name":"Indeno(1,2,3-cd)piren"},{"name":"Zakres","range":"(0,003 − 0,040) µg/l"},{"name":"Suma WWA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA):\nZakres:\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nBenzo(g,h,i)perylen\nIndeno(1,2,3-cd)piren\nZakres (0,003 − 0,040) µg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA):\nZakres:\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nBenzo(g,h,i)perylen\nIndeno(1,2,3-cd)piren\nZakres (0,003 − 0,040) µg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA):\nZakres:\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nBenzo(g,h,i)perylen\nIndeno(1,2,3-cd)piren\nZakres (0,003 − 0,040) µg/l\nSuma WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH):","parameters_en":[{"name":"Benzo(b)fluoranthene"},{"name":"Benzo(k)fluoranthene"},{"name":"Benzo(a)pyrene"},{"name":"Benzo(g,h,i)perylene"},{"name":"Indeno(1,2,3-cd)pyrene"},{"name":"Range","range":"(0,003 − 0,040) µg/l"},{"name":"Sum of PAH (calculated)"}],"search_en":"Water, water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH): High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Water Testing Laboratory Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Benzo(g,h,i)perylene Indeno(1,2,3-cd)pyrene Range Sum of PAH (calculated) PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"苯并(b)荧蒽"},{"name":"苯并(k)荧蒽"},{"name":"苯并(a)芘"},{"name":"苯并(g,h,i)苝"},{"name":"茚并(1,2,3-cd)芘"},{"name":"范围","range":"(0,003 − 0,040) µg/l"},{"name":"多环芳烃总量（计算值）"}],"search_zh":"水、生活饮用水 高效液相色谱-荧光检测法（HPLC-FLD） 水检测实验室 苯并(b)荧蒽 苯并(k)荧蒽 苯并(a)芘 苯并(g,h,i)苝 茚并(1,2,3-cd)芘 范围 多环芳烃总量（计算值） PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f5a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie lotnych związków organicznych","parameters":[{"name":"benzen","range":"(0,10 – 5,0) µg/l"},{"name":"bromodichlorometan","range":"(0,10 – 50,0) µg/l"},{"name":"chlorek winylu","range":"(0,10 – 5,0) µg/l"},{"name":"chlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"dibromochlorometan","range":"0,10 – 50,0) µg/l"},{"name":"tribromometan","range":"(0,10 – 50,0) µg/l"},{"name":"trichlorometan (chloroform)","range":"(0,10 – 50,0) µg/l"},{"name":"trichloroeten","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachloroeten","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-dichloroetan","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"etylobenzen","range":"(0,10 – 5,0) µg/l"},{"name":"o-ksylen","range":"(0,10 – 5,0) µg/l"},{"name":"m+p ksylen","range":"(0,20 –10,0) µg/l"},{"name":"toluen","range":"(0,10 – 5,0) µg/l"},{"name":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)"},{"name":"Suma THM (z obliczeń)"},{"name":"Suma trichlorobenzenów (z obliczeń)"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Suma ksylenów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek węgla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nSuma THM (z obliczeń)\nSuma trichlorobenzenów (z obliczeń)\nSuma metaksylenu i paraksylenu (z obliczeń)\nSuma ksylenów (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek węgla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nSuma THM (z obliczeń)\nSuma trichlorobenzenów (z obliczeń)\nSuma metaksylenu i paraksylenu (z obliczeń)\nSuma ksylenów (z obliczeń)\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda Stezenie lotnych zwiazkow organicznych\nZakres:\nbenzen (0,10 – 5,0) µg/l\nbromodichlorometan (0,10 – 50,0) µg/l\nchlorek winylu (0,10 – 5,0) µg/l\nchlorobenzen (0,10 – 5,0) µg/l\ndibromochlorometan 0,10 – 50,0) µg/l\ntribromometan (0,10 – 50,0) µg/l\ntrichlorometan (chloroform) (0,10 – 50,0) µg/l\ntrichloroeten (0,10 – 5,0) µg/l\ntetrachloroeten (0,10 – 5,0) µg/l\ntetrachlorometan (tetrachlorek wegla) (0,10 – 5,0) µg/l\n1,2-dichloroetan (0,10 – 5,0) µg/l\n1,2,3-trichlorobenzen (0,10 – 5,0) µg/l\n1,2,4-trichlorobenzen (0,10 – 5,0) µg/l\netylobenzen (0,10 – 5,0) µg/l\no-ksylen (0,10 – 5,0) µg/l\nm+p ksylen (0,20 –10,0) µg/l\ntoluen (0,10 – 5,0) µg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczen)\nSuma THM (z obliczen)\nSuma trichlorobenzenow (z obliczen)\nSuma metaksylenu i paraksylenu (z obliczen)\nSuma ksylenow (z obliczen)\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Concentration of volatile organic compounds","parameters_en":[{"name":"benzene","range":"(0,10 – 5,0) µg/l"},{"name":"bromodichloromethane","range":"(0,10 – 50,0) µg/l"},{"name":"vinyl chloride","range":"(0,10 – 5,0) µg/l"},{"name":"chlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"dibromochloromethane","range":"0,10 – 50,0) µg/l"},{"name":"tribromomethane","range":"(0,10 – 50,0) µg/l"},{"name":"trichloromethane (chloroform)","range":"(0,10 – 50,0) µg/l"},{"name":"trichloroethene","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachloroethene","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-dichloroethane","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,10 – 5,0) µg/l"},{"name":"ethylbenzene","range":"(0,10 – 5,0) µg/l"},{"name":"o-xylene","range":"(0,10 – 5,0) µg/l"},{"name":"m+p xylene","range":"(0,20 –10,0) µg/l"},{"name":"toluene","range":"(0,10 – 5,0) µg/l"},{"name":"Sum of trichloroethene and tetrachloroethene (calculated)"},{"name":"Sum of THM (calculated)"},{"name":"Sum of trichlorobenzenes (calculated)"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Sum of xylenes (calculated)"}],"search_en":"Water Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Water Testing Laboratory benzene bromodichloromethane vinyl chloride chlorobenzene dibromochloromethane tribromomethane trichloromethane (chloroform) trichloroethene tetrachloroethene 1,2-dichloroethane 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene ethylbenzene o-xylene m+p xylene toluene Sum of trichloroethene and tetrachloroethene (calculated) Sum of THM (calculated) Sum of trichlorobenzenes (calculated) Sum of xylenes (calculated) PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water","search_zh":"水 挥发性有机物浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 水检测实验室 苯 一溴二氯甲烷 氯乙烯 氯苯 二溴一氯甲烷 三溴甲烷 三氯甲烷（氯仿） 三氯乙烯 四氯乙烯 1,2-二氯乙烷 1,2,3-三氯苯 1,2,4-三氯苯 乙苯 邻二甲苯 甲苯 三氯乙烯与四氯乙烯总量（由计算得出） 三卤甲烷总量（由计算得出） 三氯苯总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水","parameters_zh":[{"name":"苯","range":"(0,10 – 5,0) µg/l"},{"name":"一溴二氯甲烷","range":"(0,10 – 50,0) µg/l"},{"name":"氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"二溴一氯甲烷","range":"0,10 – 50,0) µg/l"},{"name":"三溴甲烷","range":"(0,10 – 50,0) µg/l"},{"name":"三氯甲烷（氯仿）","range":"(0,10 – 50,0) µg/l"},{"name":"三氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"四氯乙烯","range":"(0,10 – 5,0) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla)","range":"(0,10 – 5,0) µg/l"},{"name":"1,2-二氯乙烷","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,3-三氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"1,2,4-三氯苯","range":"(0,10 – 5,0) µg/l"},{"name":"乙苯","range":"(0,10 – 5,0) µg/l"},{"name":"邻二甲苯","range":"(0,10 – 5,0) µg/l"},{"name":"m+p ksylen","range":"(0,20 –10,0) µg/l"},{"name":"甲苯","range":"(0,10 – 5,0) µg/l"},{"name":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"name":"三卤甲烷总量（由计算得出）"},{"name":"三氯苯总量（由计算得出）"},{"name":"Suma metaksylenu i paraksylenu (z obliczeń)"},{"name":"Suma ksylenów (z obliczeń)"}],"lab_section_zh":"水检测实验室","methodology_zh":"挥发性有机物浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a82e5dd884ede9a1b2c3f5b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) Water Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） 水检测实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"36 °C 微生物总数"},{"_id":"6a82e5dd884ede9a1b2c3f5c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) Water Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） 水检测实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"22 °C 微生物总数"},{"_id":"6a82e5dd884ede9a1b2c3f5d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method Water Testing Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 水检测实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f5e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method Water Testing Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 水检测实验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f5f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method Water Testing Laboratory PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水检测实验室 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f60","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method Water Testing Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） 水检测实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f61","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Testing Laboratory","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, water intended for human consumption Most probable number of Escherichia coli MPN method Water Testing Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） 水检测实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a82e5dd884ede9a1b2c3f62","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method Environmental Protection Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 环境保护实验室 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f63","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieku","parameters":[{"name":"Zakres","range":"(5,0 – 40,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieku\nZakres (5,0 – 40,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieku\nZakres (5,0 – 40,0) °C PN-77/C-04584 Scieki Temperatura pobranej probki scieku\nZakres (5,0 – 40,0) °C PN-77/C-04584","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(5,0 – 40,0) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Environmental Protection Laboratory Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 40,0) °C"}],"search_zh":"污水 环境保护实验室 范围 PN-77/C-04584","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f64","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 − 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 − 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5 − 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 − 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 − 2000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Environmental Protection Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 2000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 环境保护实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f65","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 − 1100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 − 1100) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 − 1100) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 − 1100) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 − 1100) mg/l"}],"search_en":"Wastewater Sulfate concentration Gravimetric method Environmental Protection Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 1100) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 环境保护实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f66","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 280) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 280) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,20 – 280) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,20 – 280) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 280) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Environmental Protection Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 280) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 环境保护实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f67","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(10,0 − 3000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 − 3000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN- ISO 15705:2005","norm_bases":["PN- ISO 15705:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 − 3000) mg/l O2\nMetoda spektrofotometryczna PN- ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 − 3000) mg/l O2\nMetoda spektrofotometryczna PN- ISO 15705:2005","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(10,0 − 3000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Environmental Protection Laboratory Range PN- ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(10,0 − 3000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 环境保护实验室 范围 PN- ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f68","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,070 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,070 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,070 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,070 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,070 – 50,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Environmental Protection Laboratory Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,070 – 50,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 环境保护实验室 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+ Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f69","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Surfaktanty anionowe","parameters":[{"name":"Zakres","range":"(0,300 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Surfaktanty anionowe\nZakres (0,300 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Surfaktanty anionowe\nZakres (0,300 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Scieki Surfaktanty anionowe\nZakres (0,300 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"Range","range":"(0,300 – 80,0) mg/l"}],"search_en":"Wastewater Spectrophotometric method Environmental Protection Laboratory Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,300 – 80,0) mg/l"}],"search_zh":"污水 分光光度法 环境保护实验室 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Environmental Protection Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 环境保护实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Titrimetric method Environmental Protection Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 滴定法 环境保护实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (5 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Environmental Protection Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 环境保护实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"Ni","range":"(0,07 – 8,0) mg/l"},{"name":"Cu","range":"(0,05 – 5,0) mg/l"},{"name":"Zn","range":"(0,02 – 5,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nNi (0,07 – 8,0) mg/l\nCu (0,05 – 5,0) mg/l\nZn (0,02 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002, metoda A","norm_bases":["PN-ISO 8288:2002, metoda A"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nNi (0,07 – 8,0) mg/l\nCu (0,05 – 5,0) mg/l\nZn (0,02 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A Scieki Stezenie metali\nZakres:\nNi (0,07 – 8,0) mg/l\nCu (0,05 – 5,0) mg/l\nZn (0,02 – 5,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A","categories":["materials","water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Ni","range":"(0,07 – 8,0) mg/l"},{"name":"Cu","range":"(0,05 – 5,0) mg/l"},{"name":"Zn","range":"(0,02 – 5,0) mg/l"}],"search_en":"Wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory Ni Cu Zn PN-ISO 8288:2002, metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ni","range":"(0,07 – 8,0) mg/l"},{"name":"Cu","range":"(0,05 – 5,0) mg/l"},{"name":"Zn","range":"(0,02 – 5,0) mg/l"}],"search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 环境保护实验室 Ni Cu Zn PN-ISO 8288:2002, metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"Cr ogólny","range":"(2,0 – 2000) µg/l"},{"name":"Cd","range":"(0,3 – 400) µg/l"},{"name":"Pb","range":"(2,0 – 2000) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr ogólny (2,0 – 2000) µg/l\nCd (0,3 – 400) µg/l\nPb (2,0 – 2000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nCr ogólny (2,0 – 2000) µg/l\nCd (0,3 – 400) µg/l\nPb (2,0 – 2000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie metali\nZakres:\nCr ogolny (2,0 – 2000) µg/l\nCd (0,3 – 400) µg/l\nPb (2,0 – 2000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Total Cr","range":"(2,0 – 2000) µg/l"},{"name":"Cd","range":"(0,3 – 400) µg/l"},{"name":"Pb","range":"(2,0 – 2000) µg/l"}],"search_en":"Wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) Environmental Protection Laboratory Total Cr Cd Pb PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Cr ogólny","range":"(2,0 – 2000) µg/l"},{"name":"Cd","range":"(0,3 – 400) µg/l"},{"name":"Pb","range":"(2,0 – 2000) µg/l"}],"search_zh":"污水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 环境保护实验室 Cd Pb PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f6f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie wanadu","parameters":[{"name":"Zakres","range":"(5,0 – 350,0) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"Range","range":"(5,0 – 350,0) µg/l"}],"search_en":"Wastewater Electrothermal atomization atomic absorption spectrometry (ETAAS) Environmental Protection Laboratory Range PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 350,0) µg/l"}],"search_zh":"污水 电热原子化原子吸收光谱法（ETAAS） 环境保护实验室 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f70","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(10,0 − 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (10,0 − 200) mg/l\nMetoda wagowa","reference":"PB-04 wydanie 04 z dnia 01.02.2024 r.","norm_bases":["PB-04 wydanie 04 z dnia 01.02.2024 r."],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (10,0 − 200) mg/l\nMetoda wagowa PB-04 wydanie 04 z dnia 01.02.2024 r. Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (10,0 − 200) mg/l\nMetoda wagowa PB-04 wydanie 04 z dnia 01.02.2024 r.","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10,0 − 200) mg/l"}],"search_en":"Wastewater Substances extractable with petroleum ether Gravimetric method Environmental Protection Laboratory Range PB-04 wydanie 04 z dnia 01.02.2024 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 − 200) mg/l"}],"search_zh":"污水 石油醚可萃取物 重量法 环境保护实验室 范围 PB-04 wydanie 04 z dnia 01.02.2024 r.","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"环境保护实验室","methodology_zh":"石油醚可萃取物"},{"_id":"6a82e5dd884ede9a1b2c3f71","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (1,0 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (1,0 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Scieki Stezenie zelaza ogolnego\nZakres (1,0 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Environmental Protection Laboratory Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 环境保护实验室 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f72","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5 − 800) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5 − 800) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe, wody roztopowe, woda Zawiesiny ogólne\nZakres (5 − 800) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, wody opadowe, wody roztopowe, woda Zawiesiny ogolne\nZakres (5 − 800) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5 − 800) mg/l"}],"search_en":"Wastewater, rainwater, snowmelt water, water Total suspended solids (TSS) Gravimetric method Environmental Protection Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, rainwater, snowmelt water, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5 − 800) mg/l"}],"search_zh":"废水、雨水、融雪水、水 总悬浮物 重量法 环境保护实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","lab_section_zh":"环境保护实验室","test_object_zh":"废水、雨水、融雪水、水"},{"_id":"6a82e5dd884ede9a1b2c3f73","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe, woda","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,20 – 30) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe, wody roztopowe, woda Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki, wody opadowe, wody roztopowe, woda Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,20 – 30) mg/l"}],"search_en":"Wastewater, rainwater, snowmelt water, water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Environmental Protection Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Wastewater, rainwater, snowmelt water, water","parameters_zh":[{"name":"范围","range":"(0,20 – 30) mg/l"}],"search_zh":"废水、雨水、融雪水、水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 环境保护实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数","lab_section_zh":"环境保护实验室","test_object_zh":"废水、雨水、融雪水、水"},{"_id":"6a82e5dd884ede9a1b2c3f74","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wanadu","parameters":[{"name":"Zakres","range":"(5,0 – 350,0) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda Stezenie wanadu\nZakres (5,0 – 350,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"Range","range":"(5,0 – 350,0) µg/l"}],"search_en":"Water Electrothermal atomization atomic absorption spectrometry (ETAAS) Environmental Protection Laboratory Range PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,0 – 350,0) µg/l"}],"search_zh":"水 电热原子化原子吸收光谱法（ETAAS） 环境保护实验室 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f75","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (0,20 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994","norm_bases":["PN-ISO 9964-1:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie sodu\nZakres (0,20 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 Woda, woda do spozycia przez ludzi Stezenie sodu\nZakres (0,20 – 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg/l"}],"search_en":"Water, water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory Range PN-ISO 9964-1:1994","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg/l"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 环境保护实验室 范围 PN-ISO 9964-1:1994","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f76","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie potasu","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie potasu\nZakres (0,05 – 25,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994","norm_bases":["PN-ISO 9964-2:1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie potasu\nZakres (0,05 – 25,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994 Woda, woda do spozycia przez ludzi Stezenie potasu\nZakres (0,05 – 25,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Potassium concentration","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/l"}],"search_en":"Water, water intended for human consumption Potassium concentration Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory Range PN-ISO 9964-2:1994","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/l"}],"search_zh":"水、生活饮用水 钾浓度 火焰原子吸收光谱法（FAAS） 环境保护实验室 范围 PN-ISO 9964-2:1994","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钾浓度","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f77","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"Cr ogólny","range":"(2,0 – 55,0) µg/l"},{"name":"Ag","range":"(0,001 – 0,050) mg/l"},{"name":"Ni","range":"(4,0 – 200,0) µg/l"},{"name":"Cd","range":"(0,3 – 10,0) µg/l"},{"name":"Pb","range":"(2,0 – 200,0) µg/l"},{"name":"Cu","range":"(0,004 – 0,100) mg/l"},{"name":"Sb","range":"(1,5 - 30,0) µg/l"},{"name":"As","range":"(2,5 - 40,0) µg/l"},{"name":"Se","range":"(3,0 - 30,0) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr ogólny (2,0 – 55,0) µg/l\nAg (0,001 – 0,050) mg/l\nNi (4,0 – 200,0) µg/l\nCd (0,3 – 10,0) µg/l\nPb (2,0 – 200,0) µg/l\nCu (0,004 – 0,100) mg/l\nSb (1,5 - 30,0) µg/l\nAs (2,5 - 40,0) µg/l\nSe (3,0 - 30,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie metali\nZakres:\nCr ogólny (2,0 – 55,0) µg/l\nAg (0,001 – 0,050) mg/l\nNi (4,0 – 200,0) µg/l\nCd (0,3 – 10,0) µg/l\nPb (2,0 – 200,0) µg/l\nCu (0,004 – 0,100) mg/l\nSb (1,5 - 30,0) µg/l\nAs (2,5 - 40,0) µg/l\nSe (3,0 - 30,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, woda do spozycia przez ludzi Stezenie metali\nZakres:\nCr ogolny (2,0 – 55,0) µg/l\nAg (0,001 – 0,050) mg/l\nNi (4,0 – 200,0) µg/l\nCd (0,3 – 10,0) µg/l\nPb (2,0 – 200,0) µg/l\nCu (0,004 – 0,100) mg/l\nSb (1,5 - 30,0) µg/l\nAs (2,5 - 40,0) µg/l\nSe (3,0 - 30,0) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Total Cr","range":"(2,0 – 55,0) µg/l"},{"name":"Ag","range":"(0,001 – 0,050) mg/l"},{"name":"Ni","range":"(4,0 – 200,0) µg/l"},{"name":"Cd","range":"(0,3 – 10,0) µg/l"},{"name":"Pb","range":"(2,0 – 200,0) µg/l"},{"name":"Cu","range":"(0,004 – 0,100) mg/l"},{"name":"Sb","range":"(1,5 - 30,0) µg/l"},{"name":"As","range":"(2,5 - 40,0) µg/l"},{"name":"Se","range":"(3,0 - 30,0) µg/l"}],"search_en":"Water, water intended for human consumption Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) Environmental Protection Laboratory Total Cr Ag Ni Cd Pb Cu Sb As Se PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, water intended for human consumption","methodology_zh":"金属浓度","parameters_zh":[{"name":"Cr ogólny","range":"(2,0 – 55,0) µg/l"},{"name":"Ag","range":"(0,001 – 0,050) mg/l"},{"name":"Ni","range":"(4,0 – 200,0) µg/l"},{"name":"Cd","range":"(0,3 – 10,0) µg/l"},{"name":"Pb","range":"(2,0 – 200,0) µg/l"},{"name":"Cu","range":"(0,004 – 0,100) mg/l"},{"name":"Sb","range":"(1,5 - 30,0) µg/l"},{"name":"As","range":"(2,5 - 40,0) µg/l"},{"name":"Se","range":"(3,0 - 30,0) µg/l"}],"search_zh":"水、生活饮用水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 环境保护实验室 Ag Ni Cd Pb Cu Sb As Se PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f78","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie pestycydów chloroorganicznych:","parameters":[{"name":"Alachlor"},{"name":"Aldryna"},{"name":"Dieldryna"},{"name":"Heptachlor"},{"name":"Epoksyd heptachloru A"},{"name":"Metoksychlor"},{"name":"Lindan"},{"name":"Heksachlorobenzen"},{"name":"Zakres","range":"(0,010 – 0,120) µg/l"},{"name":"Suma pestycydów chloroorganicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pestycydów chloroorganicznych:\nZakres:\nAlachlor\nAldryna\nDieldryna\nHeptachlor\nEpoksyd heptachloru A\nMetoksychlor\nLindan\nHeksachlorobenzen\nZakres (0,010 – 0,120) µg/l\nSuma pestycydów chloroorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pestycydów chloroorganicznych:\nZakres:\nAlachlor\nAldryna\nDieldryna\nHeptachlor\nEpoksyd heptachloru A\nMetoksychlor\nLindan\nHeksachlorobenzen\nZakres (0,010 – 0,120) µg/l\nSuma pestycydów chloroorganicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, woda do spozycia przez ludzi Stezenie pestycydow chloroorganicznych:\nZakres:\nAlachlor\nAldryna\nDieldryna\nHeptachlor\nEpoksyd heptachloru A\nMetoksychlor\nLindan\nHeksachlorobenzen\nZakres (0,010 – 0,120) µg/l\nSuma pestycydow chloroorganicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","parameters_en":[{"name":"Alachlor"},{"name":"Aldrin"},{"name":"Dieldrin"},{"name":"Heptachlor"},{"name":"Epoksyd heptachloru A"},{"name":"Methoxychlor"},{"name":"Lindan"},{"name":"Hexachlorobenzene"},{"name":"Range","range":"(0,010 – 0,120) µg/l"},{"name":"Sum of organochlorine pesticides (calculated)"}],"search_en":"Water, water intended for human consumption Gas chromatography with electron capture detection (GC-ECD) Environmental Protection Laboratory Alachlor Aldrin Dieldrin Heptachlor Methoxychlor Hexachlorobenzene Range Sum of organochlorine pesticides (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"Alachlor"},{"name":"艾氏剂"},{"name":"狄氏剂"},{"name":"七氯"},{"name":"Epoksyd heptachloru A"},{"name":"Metoksychlor"},{"name":"Lindan"},{"name":"六氯苯"},{"name":"范围","range":"(0,010 – 0,120) µg/l"},{"name":"有机氯农药总量（由计算得出）"}],"search_zh":"水、生活饮用水 气相色谱-电子捕获检测法（GC-ECD） 环境保护实验室 艾氏剂 狄氏剂 七氯 六氯苯 范围 有机氯农药总量（由计算得出） PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水","lab_section_zh":"环境保护实验室"},{"_id":"6a82e5dd884ede9a1b2c3f79","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 50 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 50 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 50 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 50 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(10,0 – 50 000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD Spectrophotometric method Wastewater Testing Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(10,0 – 50 000) mg/l O2"}],"search_zh":"水、污水 化学需氧量 ChZT（COD） 分光光度法 废水检测实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6 000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6 000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Optical method Wastewater Testing Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6 000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 光学法 废水检测实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,80 – 500) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,80 – 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (1,80 – 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda, Scieki Stezenie azotu ogolnego\nZakres (1,80 – 500) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,80 – 500) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Wastewater Testing Laboratory Range PN-EN ISO 11905-1:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,80 – 500) mg/l"}],"search_zh":"水、污水 总氮浓度 连续流动分析（CFA）分光光度检测法 废水检测实验室 范围 PN-EN ISO 11905-1:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 250) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,10 – 250) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 250) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Wastewater Testing Laboratory Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 250) mg/l"}],"search_zh":"水、污水 总磷浓度 连续流动分析（CFA）分光光度检测法 废水检测实验室 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,005 – 50,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 Woda, Scieki Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,005 – 50,0) mg/l"}],"search_en":"Water, Wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Wastewater Testing Laboratory Range PN-EN ISO 14402:2004","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,005 – 50,0) mg/l"}],"search_zh":"水、污水 酚指数 连续流动分析（CFA）分光光度检测法 废水检测实验室 范围 PN-EN ISO 14402:2004","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"酚指数","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Surfaktanty anionowe (indeks MBAS)","parameters":[{"name":"Zakres","range":"(0,05 – 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Surfaktanty anionowe (indeks MBAS)\nZakres (0,05 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 16265:2012","norm_bases":["PN-EN ISO 16265:2012"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Surfaktanty anionowe (indeks MBAS)\nZakres (0,05 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 16265:2012 Woda, Scieki Surfaktanty anionowe (indeks MBAS)\nZakres (0,05 – 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 16265:2012","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","parameters_en":[{"name":"Range","range":"(0,05 – 50) mg/l"}],"search_en":"Water, Wastewater Continuous flow analysis (CFA) with spectrophotometric detection Wastewater Testing Laboratory Range PN-EN ISO 16265:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 废水检测实验室 范围 PN-EN ISO 16265:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f7f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(1,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (1,0 – 5000) mg/l\nMetoda wagowa","reference":"PB -04 wydanie 04 z dnia 01.02.2024 r.","norm_bases":["PB -04 wydanie 04 z dnia 01.02.2024 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (1,0 – 5000) mg/l\nMetoda wagowa PB -04 wydanie 04 z dnia 01.02.2024 r. Woda, Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (1,0 – 5000) mg/l\nMetoda wagowa PB -04 wydanie 04 z dnia 01.02.2024 r.","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(1,0 – 5000) mg/l"}],"search_en":"Water, Wastewater Substances extractable with petroleum ether Gravimetric method Wastewater Testing Laboratory Range PB -04 wydanie 04 z dnia 01.02.2024 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 5000) mg/l"}],"search_zh":"水、污水 石油醚可萃取物 重量法 废水检测实验室 范围 PB -04 wydanie 04 z dnia 01.02.2024 r.","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室","methodology_zh":"石油醚可萃取物"},{"_id":"6a82e5dd884ede9a1b2c3f80","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 50 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 50 000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Wastewater Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 50 000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 废水检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f81","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(4 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (4 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (4 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (4 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(4 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Wastewater Testing Laboratory Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(4 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 废水检测实验室 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f82","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(200,0 – 80000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (200,0 – 80000) mg/l\nMetoda wagowa","reference":"PB-48 wyd. 01 z dnia 13.02.2026 r.","norm_bases":["PB-48 wyd. 01 z dnia 13.02.2026 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Sucha pozostałość\nZakres (200,0 – 80000) mg/l\nMetoda wagowa PB-48 wyd. 01 z dnia 13.02.2026 r. Scieki Sucha pozostalosc\nZakres (200,0 – 80000) mg/l\nMetoda wagowa PB-48 wyd. 01 z dnia 13.02.2026 r.","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(200,0 – 80000) mg/l"}],"search_en":"Wastewater Dry residue Gravimetric method Wastewater Testing Laboratory Range PB-48 wyd. 01 z dnia 13.02.2026 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(200,0 – 80000) mg/l"}],"search_zh":"污水 干残渣 重量法 废水检测实验室 范围 PB-48 wyd. 01 z dnia 13.02.2026 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"干残渣","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f83","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(150 – 30000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (150 – 30000) mg/l\nMetoda wagowa","reference":"PB-48 wyd. 01 z dnia 13.02.2026 r.","norm_bases":["PB-48 wyd. 01 z dnia 13.02.2026 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje rozpuszczone\nZakres (150 – 30000) mg/l\nMetoda wagowa PB-48 wyd. 01 z dnia 13.02.2026 r. Scieki Substancje rozpuszczone\nZakres (150 – 30000) mg/l\nMetoda wagowa PB-48 wyd. 01 z dnia 13.02.2026 r.","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(150 – 30000) mg/l"}],"search_en":"Wastewater Dissolved solids Gravimetric method Wastewater Testing Laboratory Range PB-48 wyd. 01 z dnia 13.02.2026 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(150 – 30000) mg/l"}],"search_zh":"污水 溶解性固体 重量法 废水检测实验室 范围 PB-48 wyd. 01 z dnia 13.02.2026 r.","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"废水检测实验室","methodology_zh":"溶解性固体"},{"_id":"6a82e5dd884ede9a1b2c3f84","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Cynk","range":"(0,050 – 64,0) mg/l"},{"name":"Miedź","range":"(0,050 – 62,5) mg/l"},{"name":"Nikiel","range":"(0,050 – 62,5) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nCynk (0,050 – 64,0) mg/l\nMiedź (0,050 – 62,5) mg/l\nNikiel (0,050 – 62,5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN ISO 8288:2002, metoda A","norm_bases":["PN ISO 8288:2002, metoda A"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali:\nZakres:\nCynk (0,050 – 64,0) mg/l\nMiedź (0,050 – 62,5) mg/l\nNikiel (0,050 – 62,5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002, metoda A Woda, Scieki Stezenie metali:\nZakres:\nCynk (0,050 – 64,0) mg/l\nMiedz (0,050 – 62,5) mg/l\nNikiel (0,050 – 62,5) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002, metoda A","categories":["materials","water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Zinc","range":"(0,050 – 64,0) mg/l"},{"name":"Copper","range":"(0,050 – 62,5) mg/l"},{"name":"Nickel","range":"(0,050 – 62,5) mg/l"}],"search_en":"Water, Wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) Wastewater Testing Laboratory Zinc Copper Nickel PN ISO 8288:2002, metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"锌","range":"(0,050 – 64,0) mg/l"},{"name":"铜","range":"(0,050 – 62,5) mg/l"},{"name":"镍","range":"(0,050 – 62,5) mg/l"}],"search_zh":"水、污水 金属浓度： 火焰原子吸收光谱法（FAAS） 废水检测实验室 锌 铜 镍 PN ISO 8288:2002, metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室","methodology_zh":"金属浓度："},{"_id":"6a82e5dd884ede9a1b2c3f85","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Mangan","range":"(0,050 – 125) mg/l"},{"name":"Żelazo","range":"(0,200 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nMangan (0,050 – 125) mg/l\nŻelazo (0,200 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-46 wydanie 01 z dnia 26.03.2025 r.","norm_bases":["PB-46 wydanie 01 z dnia 26.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali:\nZakres:\nMangan (0,050 – 125) mg/l\nŻelazo (0,200 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-46 wydanie 01 z dnia 26.03.2025 r. Woda, Scieki Stezenie metali:\nZakres:\nMangan (0,050 – 125) mg/l\nZelazo (0,200 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-46 wydanie 01 z dnia 26.03.2025 r.","categories":["water","materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Manganese","range":"(0,050 – 125) mg/l"},{"name":"Iron","range":"(0,200 – 250) mg/l"}],"search_en":"Water, Wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) Wastewater Testing Laboratory Manganese Iron PB-46 wydanie 01 z dnia 26.03.2025 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","search_zh":"水、污水 金属浓度： 火焰原子吸收光谱法（FAAS） 废水检测实验室 锰 铁 PB-46 wydanie 01 z dnia 26.03.2025 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","parameters_zh":[{"name":"锰","range":"(0,050 – 125) mg/l"},{"name":"铁","range":"(0,200 – 250) mg/l"}],"lab_section_zh":"废水检测实验室","methodology_zh":"金属浓度："},{"_id":"6a82e5dd884ede9a1b2c3f86","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,50 – 500) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,50 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-45 wydanie 01 z dnia 26.03.2025 r.","norm_bases":["PB-45 wydanie 01 z dnia 26.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,50 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-45 wydanie 01 z dnia 26.03.2025 r. Woda, Scieki Stezenie rteci\nZakres (0,50 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-45 wydanie 01 z dnia 26.03.2025 r.","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,50 – 500) µg/l"}],"search_en":"Water, Wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Wastewater Testing Laboratory Range PB-45 wydanie 01 z dnia 26.03.2025 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 500) µg/l"}],"search_zh":"水、污水 汞浓度 原子吸收光谱法（汞齐化技术） 废水检测实验室 范围 PB-45 wydanie 01 z dnia 26.03.2025 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f87","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie arsenu","parameters":[{"name":"Zakres","range":"(1,0 – 1 000) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"computed":[],"activity":"Stężenie arsenu\nZakres (1,0 – 1 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-EN ISO 11969:1999","norm_bases":["PN-EN ISO 11969:1999"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie arsenu\nZakres (1,0 – 1 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-EN ISO 11969:1999 Woda, Scieki Stezenie arsenu\nZakres (1,0 – 1 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-EN ISO 11969:1999","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Arsenic concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1 000) µg/l"}],"search_en":"Water, Wastewater Arsenic concentration Hydride generation atomic absorption spectrometry (HGAAS) Wastewater Testing Laboratory Range PN-EN ISO 11969:1999","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 1 000) µg/l"}],"search_zh":"水、污水 砷浓度 氢化物发生原子吸收光谱法（HGAAS） 废水检测实验室 范围 PN-EN ISO 11969:1999","test_object_zh":"水、污水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","lab_section_zh":"废水检测实验室","methodology_zh":"砷浓度"},{"_id":"6a82e5dd884ede9a1b2c3f88","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Chrom","range":"(2,0 – 2 000) µg/l"},{"name":"Kadm","range":"(0,50 – 400) µg/l"},{"name":"Ołów","range":"(4,0 – 2 500) µg/l"},{"name":"Srebro","range":"(1,0 – 500) µg/l"},{"name":"Wanad","range":"(10 – 5 000) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nChrom (2,0 – 2 000) µg/l\nKadm (0,50 – 400) µg/l\nOłów (4,0 – 2 500) µg/l\nSrebro (1,0 – 500) µg/l\nWanad (10 – 5 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali:\nZakres:\nChrom (2,0 – 2 000) µg/l\nKadm (0,50 – 400) µg/l\nOłów (4,0 – 2 500) µg/l\nSrebro (1,0 – 500) µg/l\nWanad (10 – 5 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Scieki Stezenie metali:\nZakres:\nChrom (2,0 – 2 000) µg/l\nKadm (0,50 – 400) µg/l\nOlow (4,0 – 2 500) µg/l\nSrebro (1,0 – 500) µg/l\nWanad (10 – 5 000) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water","materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Chromium","range":"(2,0 – 2 000) µg/l"},{"name":"Cadmium","range":"(0,50 – 400) µg/l"},{"name":"Lead","range":"(4,0 – 2 500) µg/l"},{"name":"Silver","range":"(1,0 – 500) µg/l"},{"name":"Vanadium","range":"(10 – 5 000) µg/l"}],"search_en":"Water, Wastewater Metal concentrations: Electrothermal atomization atomic absorption spectrometry (ETAAS) Wastewater Testing Laboratory Chromium Cadmium Lead Silver Vanadium PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"铬","range":"(2,0 – 2 000) µg/l"},{"name":"镉","range":"(0,50 – 400) µg/l"},{"name":"铅","range":"(4,0 – 2 500) µg/l"},{"name":"银","range":"(1,0 – 500) µg/l"},{"name":"钒","range":"(10 – 5 000) µg/l"}],"search_zh":"水、污水 金属浓度： 电热原子化原子吸收光谱法（ETAAS） 废水检测实验室 铬 镉 铅 银 钒 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室","methodology_zh":"金属浓度："},{"_id":"6a82e5dd884ede9a1b2c3f89","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie kationów:","parameters":[{"name":"amonowych","range":"(0,050 – 1 200) mg/l"},{"name":"sodowych","range":"(0,20 – 3 000) mg/l"},{"name":"potasowych","range":"(0,20 – 2 400) mg/l"},{"name":"magnezowych","range":"(0,10 – 1 200) mg/l"},{"name":"wapniowych","range":"(0,20 – 2 400) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów:\nZakres:\namonowych (0,050 – 1 200) mg/l\nsodowych (0,20 – 3 000) mg/l\npotasowych (0,20 – 2 400) mg/l\nmagnezowych (0,10 – 1 200) mg/l\nwapniowych (0,20 – 2 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie kationów:\nZakres:\namonowych (0,050 – 1 200) mg/l\nsodowych (0,20 – 3 000) mg/l\npotasowych (0,20 – 2 400) mg/l\nmagnezowych (0,10 – 1 200) mg/l\nwapniowych (0,20 – 2 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, Scieki Stezenie kationow:\nZakres:\namonowych (0,050 – 1 200) mg/l\nsodowych (0,20 – 3 000) mg/l\npotasowych (0,20 – 2 400) mg/l\nmagnezowych (0,10 – 1 200) mg/l\nwapniowych (0,20 – 2 400) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Cation concentrations:","search_en":"Water, Wastewater Cation concentrations: Ion chromatography with conductometric detection (IC-CD) Wastewater Testing Laboratory PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","search_zh":"水、污水 阳离子浓度： 离子色谱-电导检测法（IC-CD） 废水检测实验室 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室","methodology_zh":"阳离子浓度："},{"_id":"6a82e5dd884ede9a1b2c3f8a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"fluorkowych","range":"(0,10– 100) mg/l"},{"name":"chlorkowych","range":"(0,10 – 2 000) mg/l"},{"name":"azotynowych","range":"(0,10 – 100) mg/l"},{"name":"azotanowych","range":"(0,10 – 500) mg/l"},{"name":"fosforanowych","range":"(0,10 – 200) mg/l"},{"name":"siarczanowych","range":"(0,10 – 2 000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nfluorkowych (0,10– 100) mg/l\nchlorkowych (0,10 – 2 000) mg/l\nazotynowych (0,10 – 100) mg/l\nazotanowych (0,10 – 500) mg/l\nfosforanowych (0,10 – 200) mg/l\nsiarczanowych (0,10 – 2 000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie anionów:\nZakres:\nfluorkowych (0,10– 100) mg/l\nchlorkowych (0,10 – 2 000) mg/l\nazotynowych (0,10 – 100) mg/l\nazotanowych (0,10 – 500) mg/l\nfosforanowych (0,10 – 200) mg/l\nsiarczanowych (0,10 – 2 000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow:\nZakres:\nfluorkowych (0,10– 100) mg/l\nchlorkowych (0,10 – 2 000) mg/l\nazotynowych (0,10 – 100) mg/l\nazotanowych (0,10 – 500) mg/l\nfosforanowych (0,10 – 200) mg/l\nsiarczanowych (0,10 – 2 000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Anion concentrations:","search_en":"Water, Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) Wastewater Testing Laboratory PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","methodology_zh":"阴离子浓度：","search_zh":"水、污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 废水检测实验室 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f8b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie Laboratorium","flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Wastewater pH Potentiometric method Wastewater Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 废水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f8c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość arsenu","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-EN ISO 11969:1999 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","norm_bases":["PN-EN ISO 11969:1999","IU-01/IL-G wydanie z dnia 03.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość arsenu\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-EN ISO 11969:1999 | IU-01/IL-G wydanie z dnia 03.03.2025 r. Osady sciekowe Zawartosc arsenu\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-EN ISO 11969:1999 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Arsenic content","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) mg/kg"}],"search_en":"Sewage sludge Arsenic content Hydride generation atomic absorption spectrometry (HGAAS) Wastewater Testing Laboratory Range PN-EN ISO 11969:1999 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) mg/kg"}],"search_zh":"污泥 砷含量 氢化物发生原子吸收光谱法（HGAAS） 废水检测实验室 范围 PN-EN ISO 11969:1999 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","test_object_zh":"污泥","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"砷含量","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f8d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,05 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-45 wydanie 01 z dnia 26.03.2025 r.","norm_bases":["PB-45 wydanie 01 z dnia 26.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,05 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-45 wydanie 01 z dnia 26.03.2025 r. Osady sciekowe Zawartosc rteci\nZakres (0,05 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-45 wydanie 01 z dnia 26.03.2025 r.","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/kg"}],"search_en":"Sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Wastewater Testing Laboratory Range PB-45 wydanie 01 z dnia 26.03.2025 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Sewage sludge","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/kg"}],"search_zh":"污泥 汞含量 原子吸收光谱法（汞齐化技术） 废水检测实验室 范围 PB-45 wydanie 01 z dnia 26.03.2025 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污泥","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f8e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali:","parameters":[{"name":"Magnez","range":"(24 – 300 000) mg/kg"},{"name":"Wapń","range":"(160 – 500 000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nMagnez (24 – 300 000) mg/kg\nWapń (160 – 500 000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","norm_bases":["PN-EN ISO 7980:2002","IU-01/IL-G wydanie z dnia 03.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali:\nZakres:\nMagnez (24 – 300 000) mg/kg\nWapń (160 – 500 000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | IU-01/IL-G wydanie z dnia 03.03.2025 r. Osady sciekowe Zawartosc metali:\nZakres:\nMagnez (24 – 300 000) mg/kg\nWapn (160 – 500 000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","categories":["water","materials"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"Magnesium","range":"(24 – 300 000) mg/kg"},{"name":"Calcium","range":"(160 – 500 000) mg/kg"}],"search_en":"Sewage sludge Metal content: Flame atomic absorption spectrometry (FAAS) Wastewater Testing Laboratory Magnesium Calcium PN-EN ISO 7980:2002 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","search_zh":"污泥 金属含量： 火焰原子吸收光谱法（FAAS） 废水检测实验室 镁 钙 PN-EN ISO 7980:2002 | IU-01/IL-G wydanie z dnia 03.03.2025 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","parameters_zh":[{"name":"镁","range":"(24 – 300 000) mg/kg"},{"name":"钙","range":"(160 – 500 000) mg/kg"}],"lab_section_zh":"废水检测实验室","methodology_zh":"金属含量："},{"_id":"6a82e5dd884ede9a1b2c3f8f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali:","parameters":[{"name":"Mangan","range":"(25 – 62 500) mg/kg"},{"name":"Żelazo","range":"(100 – 250 000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nMangan (25 – 62 500) mg/kg\nŻelazo (100 – 250 000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-46 wydanie 01 z dnia 26.03.2025 r.","norm_bases":["PB-46 wydanie 01 z dnia 26.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali:\nZakres:\nMangan (25 – 62 500) mg/kg\nŻelazo (100 – 250 000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-46 wydanie 01 z dnia 26.03.2025 r. Osady sciekowe Zawartosc metali:\nZakres:\nMangan (25 – 62 500) mg/kg\nZelazo (100 – 250 000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-46 wydanie 01 z dnia 26.03.2025 r.","categories":["water","materials"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"Manganese","range":"(25 – 62 500) mg/kg"},{"name":"Iron","range":"(100 – 250 000) mg/kg"}],"search_en":"Sewage sludge Metal content: Flame atomic absorption spectrometry (FAAS) Wastewater Testing Laboratory Manganese Iron PB-46 wydanie 01 z dnia 26.03.2025 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","search_zh":"污泥 金属含量： 火焰原子吸收光谱法（FAAS） 废水检测实验室 锰 铁 PB-46 wydanie 01 z dnia 26.03.2025 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","parameters_zh":[{"name":"锰","range":"(25 – 62 500) mg/kg"},{"name":"铁","range":"(100 – 250 000) mg/kg"}],"lab_section_zh":"废水检测实验室","methodology_zh":"金属含量："},{"_id":"6a82e5dd884ede9a1b2c3f90","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali:","parameters":[{"name":"Cynk","range":"(25 – 64 000) mg/kg"},{"name":"Miedź","range":"(25 – 62 500) mg/kg"},{"name":"Nikiel","range":"(25 – 62 500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nCynk (25 – 64 000) mg/kg\nMiedź (25 – 62 500) mg/kg\nNikiel (25 – 62 500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN ISO 8288:2002. metoda A | IU-01/IL-G wydanie z dnia 03.03.2025 r.","norm_bases":["PN ISO 8288:2002. metoda A","IU-01/IL-G wydanie z dnia 03.03.2025 r."],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali:\nZakres:\nCynk (25 – 64 000) mg/kg\nMiedź (25 – 62 500) mg/kg\nNikiel (25 – 62 500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002. metoda A | IU-01/IL-G wydanie z dnia 03.03.2025 r. Osady sciekowe Zawartosc metali:\nZakres:\nCynk (25 – 64 000) mg/kg\nMiedz (25 – 62 500) mg/kg\nNikiel (25 – 62 500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002. metoda A | IU-01/IL-G wydanie z dnia 03.03.2025 r.","categories":["materials","water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"Zinc","range":"(25 – 64 000) mg/kg"},{"name":"Copper","range":"(25 – 62 500) mg/kg"},{"name":"Nickel","range":"(25 – 62 500) mg/kg"}],"search_en":"Sewage sludge Metal content: Flame atomic absorption spectrometry (FAAS) Wastewater Testing Laboratory Zinc Copper Nickel PN ISO 8288:2002. metoda A | IU-01/IL-G wydanie z dnia 03.03.2025 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"锌","range":"(25 – 64 000) mg/kg"},{"name":"铜","range":"(25 – 62 500) mg/kg"},{"name":"镍","range":"(25 – 62 500) mg/kg"}],"search_zh":"污泥 金属含量： 火焰原子吸收光谱法（FAAS） 废水检测实验室 锌 铜 镍 PN ISO 8288:2002. metoda A | IU-01/IL-G wydanie z dnia 03.03.2025 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"金属含量："},{"_id":"6a82e5dd884ede9a1b2c3f91","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali:","parameters":[{"name":"Chrom","range":"(1,0 – 1 000) mg/kg"},{"name":"Kadm","range":"(0,25 – 100) mg/kg"},{"name":"Ołów","range":"(2,0 – 500) mg/kg"},{"name":"Srebro","range":"(0,50 – 250) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nChrom (1,0 – 1 000) mg/kg\nKadm (0,25 – 100) mg/kg\nOłów (2,0 – 500) mg/kg\nSrebro (0,50 – 250) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali:\nZakres:\nChrom (1,0 – 1 000) mg/kg\nKadm (0,25 – 100) mg/kg\nOłów (2,0 – 500) mg/kg\nSrebro (0,50 – 250) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Osady sciekowe Zawartosc metali:\nZakres:\nChrom (1,0 – 1 000) mg/kg\nKadm (0,25 – 100) mg/kg\nOlow (2,0 – 500) mg/kg\nSrebro (0,50 – 250) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water","materials"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"Chromium","range":"(1,0 – 1 000) mg/kg"},{"name":"Cadmium","range":"(0,25 – 100) mg/kg"},{"name":"Lead","range":"(2,0 – 500) mg/kg"},{"name":"Silver","range":"(0,50 – 250) mg/kg"}],"search_en":"Sewage sludge Metal content: Electrothermal atomization atomic absorption spectrometry (ETAAS) Wastewater Testing Laboratory Chromium Cadmium Lead Silver PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"铬","range":"(1,0 – 1 000) mg/kg"},{"name":"镉","range":"(0,25 – 100) mg/kg"},{"name":"铅","range":"(2,0 – 500) mg/kg"},{"name":"银","range":"(0,50 – 250) mg/kg"}],"search_zh":"污泥 金属含量： 电热原子化原子吸收光谱法（ETAAS） 废水检测实验室 铬 镉 铅 银 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"金属含量："},{"_id":"6a82e5dd884ede9a1b2c3f92","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(5,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wyłączeniem p. 7.4, 8.2","norm_bases":["PN-EN 15935:2022-01 z wyłączeniem p. 7.4, 8.2"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wyłączeniem p. 7.4, 8.2 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wylaczeniem p. 7.4, 8.2","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(5,0 – 90,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Wastewater Testing Laboratory Range PN-EN 15935:2022-01 z wyłączeniem p. 7.4, 8.2","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 90,0) %"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 废水检测实验室 范围 PN-EN 15935:2022-01 z wyłączeniem p. 7.4, 8.2","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"废水检测实验室","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a82e5dd884ede9a1b2c3f93","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość i zawartość wody","parameters":[{"name":"Zakres","range":"(5,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość i zawartość wody\nZakres (5,0 – 30,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Laboratorium Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość i zawartość wody\nZakres (5,0 – 30,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe Sucha pozostalosc i zawartosc wody\nZakres (5,0 – 30,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory","methodology_en":"Dry residue and water content","parameters_en":[{"name":"Range","range":"(5,0 – 30,0) %"}],"search_en":"Sewage sludge Dry residue and water content Gravimetric method Wastewater Testing Laboratory Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 30,0) %"}],"search_zh":"污泥 重量法 废水检测实验室 范围 PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"废水检测实验室"},{"_id":"6a82e5dd884ede9a1b2c3f94","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2003 p. 4.1.6 | PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2003 p. 4.1.6","PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2003 p. 4.1.6 | PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2003 p. 4.1.6 | PN-ISO 5667-5:2017-10","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2003 p. 4.1.6 | PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2003 p. 4.1.6 | PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a82e5dd884ede9a1b2c3f95","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura wody","parameters":[{"name":"Zakres","range":"(2,0 − 22,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura wody\nZakres (2,0 − 22,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura wody\nZakres (2,0 − 22,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura wody\nZakres (2,0 − 22,0) °C PN-77/C-04584","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water temperature","parameters_en":[{"name":"Range","range":"(2,0 − 22,0) °C"}],"search_en":"Water intended for human consumption Water temperature Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 − 22,0) °C"}],"search_zh":"生活饮用水 水温 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"水温"},{"_id":"6a82e5dd884ede9a1b2c3f96","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt od 4.4.3. do 4.4.6","categories":["water","microbiology"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3f97","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Free chlorine concentration Colorimetric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 比色法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3f98","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru ogólnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru ogolnego\nZakres (0,03 – 1,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Total chlorine concentration Colorimetric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 总氯浓度 比色法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水","methodology_zh":"总氯浓度"},{"_id":"6a82e5dd884ede9a1b2c3f99","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru związanego (chloraminy) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (chloraminy) (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru związanego (chloraminy) (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru zwiazanego (chloraminy) (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, water intended for human consumption PN-EN ISO 7393-2:2018-04","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3f9a","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 − 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 − 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3f9b","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6, 8.2, 9.4","PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem p. 7.3, 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a82e5dd884ede9a1b2c3f9c","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PB-47 wydanie 02 z dnia 22.05.2025 r.","norm_bases":["PB-47 wydanie 02 z dnia 22.05.2025 r."],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C PB-47 wydanie 02 z dnia 22.05.2025 r. Woda Temperatura pobranej probki wody\nZakres (0,0 – 50,0) °C PB-47 wydanie 02 z dnia 22.05.2025 r.","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Temperature of the collected water sample Range PB-47 wydanie 02 z dnia 22.05.2025 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 所采水样的温度 范围 PB-47 wydanie 02 z dnia 22.05.2025 r.","test_object_zh":"水","methodology_zh":"所采水样的温度"},{"_id":"6a82e5dd884ede9a1b2c3f9d","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a82e5dd884ede9a1b2c3f9e","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura ścieków / pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura ścieków / pobranej próbki ścieków\nZakres (0,0 – 50,0) °C","reference":"PB-47 wydanie 02 z dnia 22.05.2025 r.","norm_bases":["PB-47 wydanie 02 z dnia 22.05.2025 r."],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura ścieków / pobranej próbki ścieków\nZakres (0,0 – 50,0) °C PB-47 wydanie 02 z dnia 22.05.2025 r. Scieki Temperatura sciekow / pobranej probki sciekow\nZakres (0,0 – 50,0) °C PB-47 wydanie 02 z dnia 22.05.2025 r.","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of wastewater / collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Temperature of wastewater / collected wastewater sample Range PB-47 wydanie 02 z dnia 22.05.2025 r.","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 废水/所采废水样品的温度 范围 PB-47 wydanie 02 z dnia 22.05.2025 r.","test_object_zh":"污水","methodology_zh":"废水/所采废水样品的温度"},{"_id":"6a82e5dd884ede9a1b2c3f9f","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 50 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 50 000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 50 000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a82e5dd884ede9a1b2c3fa0","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a82e5dd884ede9a1b2c3fa1","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.7, 6.3.9","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.7, 6.3.9"],"lab_section":"Laboratorium Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.7, 6.3.9 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.3, 6.3.7, 6.3.9","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.7, 6.3.9","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.7, 6.3.9","test_object_zh":"污泥"},{"_id":"6a82e5dd884ede9a1b2c3fa2","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fa3","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura wody / pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 30,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura wody / pobranej próbki wody\nZakres (0,0 – 30,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura wody / pobranej próbki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura wody / pobranej probki wody\nZakres (0,0 – 30,0) °C PN-77/C-04584","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of water / of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 30,0) °C"}],"search_en":"Water intended for human consumption Temperature of water / of the collected water sample Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 30,0) °C"}],"search_zh":"生活饮用水 水/所采水样的温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"水/所采水样的温度"},{"_id":"6a82e5dd884ede9a1b2c3fa4","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda *)","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 − 100) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 − 100) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda *) Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 − 100) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda *) Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 − 100) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 − 100) mg/l O2"}],"search_en":"Water *) Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water *)","parameters_zh":[{"name":"范围","range":"(10 − 100) mg/l O2"}],"search_zh":"化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a82e5dd884ede9a1b2c3fa5","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda *)","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda *) Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda *) Zawiesiny ogolne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Water *) Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water *)","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a82e5dd884ede9a1b2c3fa6","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 − 6,44) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 − 6,44) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie jonu amonowego\nZakres (0,06 − 6,44) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi *) Stezenie jonu amonowego\nZakres (0,06 − 6,44) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 − 6,44) mg/l"}],"search_en":"Water, water intended for human consumption *) Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 − 6,44) mg/l"}],"search_zh":"水、生活饮用水 *) 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fa7","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,040 − 0,800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,040 − 0,800) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie azotynów\nZakres (0,040 − 0,800) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi *) Stezenie azotynow\nZakres (0,040 − 0,800) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,040 − 0,800) mg/l"}],"search_en":"Water, water intended for human consumption *) Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,040 − 0,800) mg/l"}],"search_zh":"水、生活饮用水 *) 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fa8","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie chlorków\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi *) Stezenie chlorkow\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 150) mg/l"}],"search_en":"Water, water intended for human consumption *) Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 150) mg/l"}],"search_zh":"水、生活饮用水 *) 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fa9","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3 − 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3 − 70) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Barwa\nZakres (3 − 70) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, woda do spozycia przez ludzi *) Barwa\nZakres (3 − 70) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(3 − 70) mg/l"}],"search_en":"Water, water intended for human consumption *) Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 − 70) mg/l"}],"search_zh":"水、生活饮用水 *) 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3faa","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 − 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda D","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, woda do spozycia przez ludzi *) Barwa\nZakres (5 − 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 − 40) mg/l Pt"}],"search_en":"Water, water intended for human consumption *) Colour Visual method Range PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 40) mg/l Pt"}],"search_zh":"水、生活饮用水 *) 色度 目视法 范围 PN-EN ISO 7887:2012 metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fab","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(20 − 1000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (20 − 1000) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie żelaza ogólnego\nZakres (20 − 1000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, woda do spozycia przez ludzi *) Stezenie zelaza ogolnego\nZakres (20 − 1000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(20 − 1000) µg/l"}],"search_en":"Water, water intended for human consumption *) Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(20 − 1000) µg/l"}],"search_zh":"水、生活饮用水 *) 总铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fac","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 − 5000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna","reference":"PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","norm_bases":["PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008 Woda, woda do spozycia przez ludzi *) Stezenie zelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 − 5000) µg/l"}],"search_en":"Water, water intended for human consumption *) Iron concentration Spectrophotometric method Range PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 − 5000) µg/l"}],"search_zh":"水、生活饮用水 *) 铁浓度 分光光度法 范围 PB-32 wydanie 02 z dnia 11.02.2016 r. na podstawie metody HACH Nr 8008","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fad","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,40 − 55) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,40 − 55) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie azotanów\nZakres (0,40 − 55) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi *) Stezenie azotanow\nZakres (0,40 − 55) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,40 − 55) mg/l"}],"search_en":"Water, water intended for human consumption *) Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,40 − 55) mg/l"}],"search_zh":"水、生活饮用水 *) 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fae","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 15,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 15,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Indeks nadmanganianowy\nZakres (0,50 – 15,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi *) Indeks nadmanganianowy\nZakres (0,50 – 15,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 15,0) mg/l"}],"search_en":"Water, water intended for human consumption *) Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 15,0) mg/l"}],"search_zh":"水、生活饮用水 *) 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3faf","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 − 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 − 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi *) Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 − 500) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption *) Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 − 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 *) 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb0","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 − 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 − 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie wapnia\nZakres (2 − 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi *) Stezenie wapnia\nZakres (2 − 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 − 200) mg/l"}],"search_en":"Water, water intended for human consumption *) Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption *)","parameters_zh":[{"name":"范围","range":"(2 − 200) mg/l"}],"search_zh":"水、生活饮用水 *) 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","methodology_zh":"钙浓度","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb1","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 zał. A","norm_bases":["PN-C-04554-4:1999 zał. A"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 zał. A Woda, woda do spozycia przez ludzi *) Stezenie magnezu (z obliczen) PN-C-04554-4:1999 zal. A","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption *) Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"镁浓度（计算值）","search_zh":"水、生活饮用水 *) 镁浓度（计算值） PN-C-04554-4:1999 zał. A","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb2","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 − 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 − 100) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie siarczanów\nZakres (10 − 100) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi *) Stezenie siarczanow\nZakres (10 − 100) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 − 100) mg/l"}],"search_en":"Water, water intended for human consumption *) Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 100) mg/l"}],"search_zh":"水、生活饮用水 *) 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb3","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(30 – 500) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (30 – 500) µg/l\nMetoda spektrofotometryczna","reference":"PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","norm_bases":["PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie glinu\nZakres (30 – 500) µg/l\nMetoda spektrofotometryczna PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301 Woda, woda do spozycia przez ludzi *) Stezenie glinu\nZakres (30 – 500) µg/l\nMetoda spektrofotometryczna PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(30 – 500) µg/l"}],"search_en":"Water, water intended for human consumption *) Aluminium concentration Spectrophotometric method Range PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","parameters_zh":[{"name":"范围","range":"(30 – 500) µg/l"}],"search_zh":"水、生活饮用水 *) 铝浓度 分光光度法 范围 PB-31 wyd. 02 z dnia 15.01.2019 r. na podstawie testu kuwetowego HACH Nr LCK 301","technique_zh":"分光光度法","methodology_zh":"铝浓度","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb4","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 700) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 700) µg/l\nMetoda spektrofotometryczna","reference":"PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","norm_bases":["PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie manganu\nZakres (15 – 700) µg/l\nMetoda spektrofotometryczna PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149 Woda, woda do spozycia przez ludzi *) Stezenie manganu\nZakres (15 – 700) µg/l\nMetoda spektrofotometryczna PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","categories":["water"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 700) µg/l"}],"search_en":"Water, water intended for human consumption *) Manganese concentration Spectrophotometric method Range PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 700) µg/l"}],"search_zh":"水、生活饮用水 *) 锰浓度 分光光度法 范围 PB-33 wyd. 03 z dnia 15.12.2021 r. na podstawie metody HACH Nr 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb5","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(147 − 1500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 − 1500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Przewodność elektryczna właściwa\nZakres (147 − 1500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi *) Przewodnosc elektryczna wlasciwa\nZakres (147 − 1500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(147 − 1500) µS/cm"}],"search_en":"Water, water intended for human consumption *) Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 − 1500) µS/cm"}],"search_zh":"水、生活饮用水 *) 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb6","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 4,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Mętność\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi *) Metnosc\nZakres (0,20 – 4,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 4,0) NTU"}],"search_en":"Water, water intended for human consumption *) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 4,0) NTU"}],"search_zh":"水、生活饮用水 *) 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb7","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi *) pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption *) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 *) pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb8","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna","reference":"PB-29 wyd. 03 z dnia 13.03.2017 r.","norm_bases":["PB-29 wyd. 03 z dnia 13.03.2017 r."],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-29 wyd. 03 z dnia 13.03.2017 r. Woda, woda do spozycia przez ludzi *) Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-29 wyd. 03 z dnia 13.03.2017 r.","categories":["water"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption *) Free chlorine concentration Colorimetric method Range PB-29 wyd. 03 z dnia 13.03.2017 r.","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 *) 游离氯浓度 比色法 范围 PB-29 wyd. 03 z dnia 13.03.2017 r.","technique_zh":"比色法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fb9","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna","reference":"PB-29 wyd. 03 z dnia 13.03.2017 r.","norm_bases":["PB-29 wyd. 03 z dnia 13.03.2017 r."],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-29 wyd. 03 z dnia 13.03.2017 r. Woda, woda do spozycia przez ludzi *) Stezenie chloru ogolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-29 wyd. 03 z dnia 13.03.2017 r.","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption *) Total chlorine concentration Colorimetric method Range PB-29 wyd. 03 z dnia 13.03.2017 r.","technique_en":"Colorimetric method","test_object_en":"Water, water intended for human consumption *)","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 *) 总氯浓度 比色法 范围 PB-29 wyd. 03 z dnia 13.03.2017 r.","technique_zh":"比色法","methodology_zh":"总氯浓度","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fba","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi *)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167","norm_bases":["PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":"badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi *) Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167 Woda, woda do spozycia przez ludzi *) Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption *) Free chlorine concentration Spectrophotometric method Range PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption *)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 *) 游离氯浓度 分光光度法 范围 PB-39 wyd. 01 z dnia 15.01.2019 r. na podstawie metody HACH Nr 8021, Nr 8167","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水 *)"},{"_id":"6a82e5dd884ede9a1b2c3fbb","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. od 4.4.3 do 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. od 4.4.3 do 4.4.6"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. od 4.4.3 do 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. od 4.4.3 do 4.4.6","categories":["water","microbiology"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. od 4.4.3 do 4.4.6","test_object_en":"Water, water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. od 4.4.3 do 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fbc","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2: 2004","norm_bases":["PN-EN ISO 7899-2: 2004"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2: 2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2: 2004","categories":["water"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2: 2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2: 2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fbd","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fbe","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fbf","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a82e5dd884ede9a1b2c3fc0","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a82e5dd884ede9a1b2c3fc1","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a82e5dd884ede9a1b2c3fc2","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a82e5dd884ede9a1b2c3fc3","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a82e5dd884ede9a1b2c3fc4","lab_id":"69ad52a3de79e566650fb77a","country":"PL","accr_number":"AB 1448","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL","reference":"PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX","norm_bases":["PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX"],"lab_section":"Laboratorium Badania Wody – Oddział Tomaszów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX","categories":["water"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Pseudomonas aeruginosa","search_en":"Water, water intended for human consumption Most probable number of Pseudomonas aeruginosa MPN method PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 最可能数法（MPN） PB-38 wyd. 02 z dnia 08.04.2019 r. na podstawie testu PseudalertTM firmy IDEXX","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"}],"has_pdf":true}