{"lab":{"_id":"69ad52a3de79e566650fb774","accr_number":"AB 1443","country":"PL","accr_body":"PCA","address":"I KANALIZACJI S.A., DZIAŁ LABORATORIUM, ul. Nowodworska 1, 59-220 Legnica","categories":["water","materials"],"city":"Legnica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":31,"name":"LEGNICKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1443.pdf"],"scope_summary":"","search_text":"legnickie przedsiębiorstwo wodociągów i kanalizacji s.a., dział laboratorium, ul. nowodworska 1, 59-220 legnica water other materials pharma electronics","status":"active","updated_at":"2026-03-08T14:50:36.097Z","valid_from":"","valid_until":"21.07.2029","website":"","parsed_at":"2026-08-17T10:33:59.568Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201443,podmiot.html","parse_date":"2026-08-17T10:33:59.568Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"14","date":"08.06.2026"},"map_coord":[51.165369,16.147462],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ LABORATORIUM","address":"ul. Nowodworska 1","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/b0fca10cce9eeae0fe348970b50197dc/AB%201443.pdf","has_en":true,"category_counts":{"water":31,"materials":2},"category_scores":{"water":29.12,"materials":0.12},"has_zh":true},"methods":[{"_id":"6a82e397884ede9a1b2c39b1","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,4 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,4 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,4 − 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi, Woda, Scieki Stezenie azotu azotanowego\nZakres (0,4 − 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,4 − 50) mg/l"}],"search_en":"Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,4 − 50) mg/l"}],"search_zh":"硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法"},{"_id":"6a82e397884ede9a1b2c39b2","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 − 0,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 − 0,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda, Ścieki Stężenie azotynów\nZakres (0,010 − 0,30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, Woda, Scieki Stezenie azotynow\nZakres (0,010 − 0,30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 − 0,30) mg/l"}],"search_en":"Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 0,30) mg/l"}],"search_zh":"亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法"},{"_id":"6a82e397884ede9a1b2c39b3","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda, Ścieki Stężenie chlorków\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, Woda, Scieki Stezenie chlorkow\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 − 1000) mg/l"}],"search_en":"Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 − 1000) mg/l"}],"search_zh":"氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法"},{"_id":"6a82e397884ede9a1b2c39b4","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, Woda, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a82e397884ede9a1b2c39b5","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20 − 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20 − 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (20 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (20 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(20 − 500) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 − 500) mg/l"}],"search_zh":"生活饮用水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"生活饮用水、废水"},{"_id":"6a82e397884ede9a1b2c39b6","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e397884ede9a1b2c39b7","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (1,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura pobranej próbki wody\nZakres (1,0 – 35,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura pobranej probki wody\nZakres (1,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(1,0 – 35,0) °C"}],"search_en":"Water intended for human consumption Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 – 35,0) °C"}],"search_zh":"生活饮用水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"所采水样的温度"},{"_id":"6a82e397884ede9a1b2c39b8","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 8,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 8,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 pkt 5.3","norm_bases":["PN-EN ISO 7027-1:2016-09 pkt 5.3"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 8,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 pkt 5.3 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 8,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 pkt 5.3","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 8,0) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 pkt 5.3","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 8,0) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 pkt 5.3","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a82e397884ede9a1b2c39b9","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 0,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 0,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,02 – 0,5) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,02 – 0,5) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 0,5) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 0,5) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a82e397884ede9a1b2c39ba","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7","norm_bases":["PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-6:2016-12 z wylaczeniem punktow 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7","test_object_zh":"水"},{"_id":"6a82e397884ede9a1b2c39bb","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (1,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura pobranej próbki wody\nZakres (1,0 – 35,0) °C PN-77/C-04584 Woda Temperatura pobranej probki wody\nZakres (1,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(1,0 – 35,0) °C"}],"search_en":"Water Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 35,0) °C"}],"search_zh":"水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"所采水样的温度"},{"_id":"6a82e397884ede9a1b2c39bc","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr","parameters":[{"name":"Zakres","range":"(9 – 120) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 120) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 120) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 120) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(9 – 120) mg/l O2"}],"search_en":"Water Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(9 – 120) mg/l O2"}],"search_zh":"水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82e397884ede9a1b2c39bd","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20− 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20− 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie siarczanów\nZakres (20− 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow\nZakres (20− 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(20− 500) mg/l"}],"search_en":"Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20− 500) mg/l"}],"search_zh":"水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a82e397884ede9a1b2c39be","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,10 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu\nZakres (0,10 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie fosforu\nZakres (0,10 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) mg/l"}],"search_en":"Water Phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) mg/l"}],"search_zh":"水 磷浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水","methodology_zh":"磷浓度"},{"_id":"6a82e397884ede9a1b2c39bf","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 − 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (2,0 − 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (2,0 − 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 − 1000) mg/l"}],"search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 1000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a82e397884ede9a1b2c39c0","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie fenoli (indeks fenolowy)","parameters":[{"name":"Zakres","range":"(0,002 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fenoli (indeks fenolowy)\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie fenoli (indeks fenolowy)\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Scieki, Woda Stezenie fenoli (indeks fenolowy)\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,002 – 0,10) mg/l"}],"search_en":"Wastewater, Water Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"范围","range":"(0,002 – 0,10) mg/l"}],"search_zh":"废水、水 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a82e397884ede9a1b2c39c1","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 80) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 80) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu Kjeldahla\nZakres (1,0 – 80) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, Woda Stezenie azotu Kjeldahla\nZakres (1,0 – 80) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 80) mg/l"}],"search_en":"Wastewater, Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater, Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 80) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a82e397884ede9a1b2c39c2","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(1 – 2000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 2000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(1 – 2000) mg/l O2"}],"search_en":"Wastewater, Water Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"范围","range":"(1 – 2000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82e397884ede9a1b2c39c3","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki, Woda Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater, Water Total nitrogen concentration (calculated) PN-73/C-04576/14","test_object_en":"Wastewater, Water","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"废水、水"},{"_id":"6a82e397884ede9a1b2c39c4","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a82e397884ede9a1b2c39c5","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(1,0 – 35,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieków\nZakres (1,0 – 35,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieków\nZakres (1,0 – 35,0) °C PN-77/C-04584 Scieki Temperatura pobranej probki sciekow\nZakres (1,0 – 35,0) °C PN-77/C-04584","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(1,0 – 35,0) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 35,0) °C"}],"search_zh":"污水 所采废水样品的温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"所采废水样品的温度"},{"_id":"6a82e397884ede9a1b2c39c6","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"chrom","range":"(0,10 – 2,0) mg/l"},{"name":"cynk","range":"(0,10 – 5,0) mg/l"},{"name":"fosfor","range":"0,10 – 50,0) mg/l"},{"name":"kadm","range":"(0,10 – 2,0) mg/l"},{"name":"miedź","range":"(0,10 – 5,0) mg/l"},{"name":"nikiel","range":"(0,10 – 2,0) mg/l"},{"name":"ołów","range":"(0,10 – 5,0) mg/l"},{"name":"arsen","range":"(0,050 – 0,50) mg/l"},{"name":"wanad","range":"(0,50 – 5,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nchrom (0,10 – 2,0) mg/l\ncynk (0,10 – 5,0) mg/l\nfosfor 0,10 – 50,0) mg/l\nkadm (0,10 – 2,0) mg/l\nmiedź (0,10 – 5,0) mg/l\nnikiel (0,10 – 2,0) mg/l\nołów (0,10 – 5,0) mg/l\narsen (0,050 – 0,50) mg/l\nwanad (0,50 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nchrom (0,10 – 2,0) mg/l\ncynk (0,10 – 5,0) mg/l\nfosfor 0,10 – 50,0) mg/l\nkadm (0,10 – 2,0) mg/l\nmiedź (0,10 – 5,0) mg/l\nnikiel (0,10 – 2,0) mg/l\nołów (0,10 – 5,0) mg/l\narsen (0,050 – 0,50) mg/l\nwanad (0,50 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nchrom (0,10 – 2,0) mg/l\ncynk (0,10 – 5,0) mg/l\nfosfor 0,10 – 50,0) mg/l\nkadm (0,10 – 2,0) mg/l\nmiedz (0,10 – 5,0) mg/l\nnikiel (0,10 – 2,0) mg/l\nolow (0,10 – 5,0) mg/l\narsen (0,050 – 0,50) mg/l\nwanad (0,50 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"chromium","range":"(0,10 – 2,0) mg/l"},{"name":"zinc","range":"(0,10 – 5,0) mg/l"},{"name":"phosphorus","range":"0,10 – 50,0) mg/l"},{"name":"cadmium","range":"(0,10 – 2,0) mg/l"},{"name":"copper","range":"(0,10 – 5,0) mg/l"},{"name":"nickel","range":"(0,10 – 2,0) mg/l"},{"name":"lead","range":"(0,10 – 5,0) mg/l"},{"name":"arsenic","range":"(0,050 – 0,50) mg/l"},{"name":"vanadium","range":"(0,50 – 5,0) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) chromium zinc phosphorus cadmium copper nickel lead arsenic vanadium PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"铬","range":"(0,10 – 2,0) mg/l"},{"name":"锌","range":"(0,10 – 5,0) mg/l"},{"name":"磷","range":"0,10 – 50,0) mg/l"},{"name":"镉","range":"(0,10 – 2,0) mg/l"},{"name":"铜","range":"(0,10 – 5,0) mg/l"},{"name":"镍","range":"(0,10 – 2,0) mg/l"},{"name":"铅","range":"(0,10 – 5,0) mg/l"},{"name":"砷","range":"(0,050 – 0,50) mg/l"},{"name":"钒","range":"(0,50 – 5,0) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 锌 磷 镉 铜 镍 铅 砷 钒 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a82e397884ede9a1b2c39c7","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr","parameters":[{"name":"Zakres","range":"(9 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - CHZT-Cr\nZakres (9 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(9 – 5000) mg/l O2"}],"search_en":"Wastewater Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(9 – 5000) mg/l O2"}],"search_zh":"污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a82e397884ede9a1b2c39c8","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 − 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 − 250) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 − 250) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 − 250) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 − 250) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 250) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a82e397884ede9a1b2c39c9","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 − 50) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 − 50) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Barwa\nZakres (2 − 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda do spozycia przez ludzi, Woda Barwa\nZakres (2 − 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 − 50) mg/l Pt"}],"search_en":"Water intended for human consumption, Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 − 50) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39ca","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(20 − 500) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (20 − 500) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt 7.1. | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 pkt 7.1.","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie żelaza ogólnego\nZakres (20 − 500) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1. | PN-ISO 6332:2001/Ap1:2016-06 Woda do spozycia przez ludzi, Woda Stezenie zelaza ogolnego\nZakres (20 − 500) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1. | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(20 − 500) µg/l"}],"search_en":"Water intended for human consumption, Water Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 pkt 7.1. | PN-ISO 6332:2001/Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(20 − 500) µg/l"}],"search_zh":"生活饮用水、水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 pkt 7.1. | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39cb","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,03 − 0,3) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,03 − 0,3) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie manganu\nZakres (0,03 − 0,3) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda do spozycia przez ludzi, Woda Stezenie manganu\nZakres (0,03 − 0,3) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,03 − 0,3) mg/l"}],"search_en":"Water intended for human consumption, Water Manganese concentration Spectrophotometric method Range PN-92/C-04590/02","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,03 − 0,3) mg/l"}],"search_zh":"生活饮用水、水 锰浓度 分光光度法 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39cc","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100,0 − 1999) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100,0 − 1999) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Przewodność elektryczna właściwa\nZakres (100,0 − 1999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, Woda Przewodnosc elektryczna wlasciwa\nZakres (100,0 − 1999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100,0 − 1999) μS/cm"}],"search_en":"Water intended for human consumption, Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100,0 − 1999) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39cd","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie metali","parameters":[{"name":"mangan","range":"(15 – 1000) µg/l"},{"name":"żelazo","range":"(15 – 1000) µg/l"},{"name":"chrom","range":"(10 –100) ) µg/l"},{"name":"kadm","range":"(1,5 – 25) µg/l"},{"name":"miedź","range":"(0,10 – 2,5) mg/l"},{"name":"nikiel","range":"(5,0 – 25) µg/l"},{"name":"ołów","range":"(3,0 – 25) µg/l"},{"name":"srebro","range":"(0,003 – 0,025) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nmangan (15 – 1000) µg/l\nżelazo (15 – 1000) µg/l\nchrom (10 –100) ) µg/l\nkadm (1,5 – 25) µg/l\nmiedź (0,10 – 2,5) mg/l\nnikiel (5,0 – 25) µg/l\nołów (3,0 – 25) µg/l\nsrebro (0,003 – 0,025) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie metali\nZakres:\nmangan (15 – 1000) µg/l\nżelazo (15 – 1000) µg/l\nchrom (10 –100) ) µg/l\nkadm (1,5 – 25) µg/l\nmiedź (0,10 – 2,5) mg/l\nnikiel (5,0 – 25) µg/l\nołów (3,0 – 25) µg/l\nsrebro (0,003 – 0,025) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda do spozycia przez ludzi, Woda Stezenie metali\nZakres:\nmangan (15 – 1000) µg/l\nzelazo (15 – 1000) µg/l\nchrom (10 –100) ) µg/l\nkadm (1,5 – 25) µg/l\nmiedz (0,10 – 2,5) mg/l\nnikiel (5,0 – 25) µg/l\nolow (3,0 – 25) µg/l\nsrebro (0,003 – 0,025) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"manganese","range":"(15 – 1000) µg/l"},{"name":"iron","range":"(15 – 1000) µg/l"},{"name":"chromium","range":"(10 –100) ) µg/l"},{"name":"cadmium","range":"(1,5 – 25) µg/l"},{"name":"copper","range":"(0,10 – 2,5) mg/l"},{"name":"nickel","range":"(5,0 – 25) µg/l"},{"name":"lead","range":"(3,0 – 25) µg/l"},{"name":"silver","range":"(0,003 – 0,025) mg/l"}],"search_en":"Water intended for human consumption, Water Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) manganese iron chromium cadmium copper nickel lead silver PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water intended for human consumption, Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"锰","range":"(15 – 1000) µg/l"},{"name":"铁","range":"(15 – 1000) µg/l"},{"name":"铬","range":"(10 –100) ) µg/l"},{"name":"镉","range":"(1,5 – 25) µg/l"},{"name":"铜","range":"(0,10 – 2,5) mg/l"},{"name":"镍","range":"(5,0 – 25) µg/l"},{"name":"铅","range":"(3,0 – 25) µg/l"},{"name":"银","range":"(0,003 – 0,025) mg/l"}],"search_zh":"生活饮用水、水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锰 铁 铬 镉 铜 镍 铅 银 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39ce","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(100 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (100 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (100 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (100 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(100 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption, Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(100 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水、水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、水"},{"_id":"6a82e397884ede9a1b2c39cf","lab_id":"69ad52a3de79e566650fb774","country":"PL","accr_number":"AB 1443","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 − 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 − 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotu amonowego\nZakres (0,05 − 0,80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, Woda Stezenie azotu amonowego\nZakres (0,05 − 0,80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 − 0,80) mg/l"}],"search_en":"Water intended for human consumption, Water Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 0,80) mg/l"}],"search_zh":"生活饮用水、水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"}],"has_pdf":true}