{"lab":{"_id":"69ad52a3de79e566650fb76c","accr_number":"AB 1437","country":"PL","accr_body":"PCA","address":"LABORATORIUM OCENY SUROWCA, ul. Żytnia 3, 08-500 Ryki","categories":["food","microbiology"],"city":"Ryki","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"SPÓŁDZIELNIA MLECZARSKA RYKI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1437.pdf"],"scope_summary":"","search_text":"spółdzielnia mleczarska ryki laboratorium oceny surowca, ul. żytnia 3, 08-500 ryki food microbiology pharma other","status":"active","updated_at":"2026-03-08T14:50:35.897Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:35.897Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201437,podmiot.html","parse_date":"2026-07-17T16:19:07.430Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"B/22","pl":"Badanie biochemiczne żywności","en":"Biochemical tests of food","de":"Biochemische Prüfung von Lebensmitteln","zh":"食品生化检测","cs":"Biochemické zkoušení potravin"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food","de":"Chemische Prüfungen von Lebensmitteln","zh":"食品化学检测","cs":"Chemické zkoušky potravin"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food","de":"Mikrobiologische Prüfungen von Lebensmitteln","zh":"食品微生物检测","cs":"Mikrobiologické zkoušky potravin"}],"issue":{"no":"9","date":"22.04.2025"},"map_coord":[51.620161,21.936856],"map_geo":"nominatim-street","has_en":true,"category_counts":{"food":4,"microbiology":1},"category_scores":{"food":3.2,"microbiology":0.2},"has_zh":true,"has_de":true,"has_cs":true,"pelny_cs":true},"methods":[{"_id":"6a5a55fb9af9f73f38252c6d","lab_id":"69ad52a3de79e566650fb76c","country":"PL","accr_number":"AB 1437","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Ogólna liczba drobnoustrojów Zakres: od 1 x 103 do 3 x 106 jtk/ml Metoda cytometrii przepływowej","methodology_en":"Total viable count Range: from 1 x 103 to 3 x 106 CFU/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów Zakres: od 1 x 103 do 3 x 106 jtk/ml Metoda cytometrii przepływowej","reference":"PB-01 wydanie 2 z dnia 01-05-2019 w oparciu o instrukcję aparatu Bactoscan FC","norm_bases":["PB-01 wydanie 2 z dnia 01-05-2019 w oparciu o instrukcję aparatu Bactoscan FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Ogólna liczba drobnoustrojów Zakres: od 1 x 103 do 3 x 106 jtk/ml Metoda cytometrii przepływowej PB-01 wydanie 2 z dnia 01-05-2019 w oparciu o instrukcję aparatu Bactoscan FC Mleko surowe krowie Ogolna liczba drobnoustrojow Zakres: od 1 x 103 do 3 x 106 jtk/ml Metoda cytometrii przeplywowej PB-01 wydanie 2 z dnia 01-05-2019 w oparciu o instrukcje aparatu Bactoscan FC","categories":["food","microbiology"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Total viable count Range: from 1 x 103 to 3 x 106 CFU/ml Flow cytometry method PB-01 issue 2 of 01.05.2019 based on the instructions for the Bactoscan FC instrument","search_zh":"生鲜牛乳 微生物总数 范围：自 1 x 103 至 3 x 106 cfu/ml 流式细胞术 PB-01 第2版（2019年5月1日）依据Bactoscan FC仪器说明书","test_object_zh":"生鲜牛乳","methodology_de":"Gesamtkeimzahl Bereich: von 1 x 103 bis 3 x 106 KBE/ml Durchflusszytometrisches Verfahren","search_de":"Kuhrohmilch Gesamtkeimzahl Bereich: von 1 x 103 bis 3 x 106 KBE/ml Durchflusszytometrisches Verfahren PB-01 Ausgabe 2 vom 01.05.2019 auf Grundlage der Anleitung des Geräts Bactoscan FC","test_object_de":"Kuhrohmilch","methodology_zh":"微生物总数 范围：自 1 x 103 至 3 x 106 cfu/ml 流式细胞术","reference_en":"PB-01 issue 2 of 01.05.2019 based on the instructions for the Bactoscan FC instrument","reference_de":"PB-01 Ausgabe 2 vom 01.05.2019 auf Grundlage der Anleitung des Geräts Bactoscan FC","reference_zh":"PB-01 第2版（2019年5月1日）依据Bactoscan FC仪器说明书","search_cs":"Syrové kravské mléko Celkový počet mikroorganismů Rozsah: od 1 x 103 do 3 x 106 KTJ/ml Metoda průtokové cytometrie PB-01 vydání 2 ze dne 01-05-2019 na základě návodu k přístroji Bactoscan FC","test_object_cs":"Syrové kravské mléko","methodology_cs":"Celkový počet mikroorganismů Rozsah: od 1 x 103 do 3 x 106 KTJ/ml Metoda průtokové cytometrie","reference_cs":"PB-01 vydání 2 ze dne 01-05-2019 na základě návodu k přístroji Bactoscan FC"},{"_id":"6a5a55fb9af9f73f38252c6e","lab_id":"69ad52a3de79e566650fb76c","country":"PL","accr_number":"AB 1437","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Liczba komórek somatycznych Zakres: od 1 x 103 do 5 x 106 komórek somatycznych/ml Metoda cytometrii przepływowej","methodology_en":"Somatic cell count Range: from 1 x 103 to 5 x 106 somatic cells/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych Zakres: od 1 x 103 do 5 x 106 komórek somatycznych/ml Metoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 7","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Liczba komórek somatycznych Zakres: od 1 x 103 do 5 x 106 komórek somatycznych/ml Metoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 7 Mleko surowe krowie Liczba komorek somatycznych Zakres: od 1 x 103 do 5 x 106 komorek somatycznych/ml Metoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 7","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Somatic cell count Range: from 1 x 103 to 5 x 106 somatic cells/ml Flow cytometry method PN-EN ISO 13366-2:2007 using the Fossomatic 7 instrument","search_zh":"生鲜牛乳 体细胞计数 范围：1 x 103 至 5 x 106 体细胞/ml 流式细胞术 PN-EN ISO 13366-2:2007 使用Fossomatic 7仪器","test_object_zh":"生鲜牛乳","methodology_de":"Somatische Zellzahl Bereich: von 1 x 103 bis 5 x 106 somatische Zellen/ml Durchflusszytometrisches Verfahren","search_de":"Kuhrohmilch Somatische Zellzahl Bereich: von 1 x 103 bis 5 x 106 somatische Zellen/ml Durchflusszytometrisches Verfahren PN-EN ISO 13366-2:2007 unter Verwendung des Geräts Fossomatic 7","test_object_de":"Kuhrohmilch","methodology_zh":"体细胞计数 范围：1 x 103 至 5 x 106 体细胞/ml 流式细胞术","reference_en":"PN-EN ISO 13366-2:2007 using the Fossomatic 7 instrument","reference_de":"PN-EN ISO 13366-2:2007 unter Verwendung des Geräts Fossomatic 7","reference_zh":"PN-EN ISO 13366-2:2007 使用Fossomatic 7仪器","search_cs":"Syrové kravské mléko Počet somatických buněk Rozsah: od 1 x 103 do 5 x 106 somatických buněk/ml Metoda průtokové cytometrie PN-EN ISO 13366-2:2007 s použitím přístroje Fossomatic 7","test_object_cs":"Syrové kravské mléko","methodology_cs":"Počet somatických buněk Rozsah: od 1 x 103 do 5 x 106 somatických buněk/ml Metoda průtokové cytometrie","reference_cs":"PN-EN ISO 13366-2:2007 s použitím přístroje Fossomatic 7"},{"_id":"6a5a55fb9af9f73f38252c6f","lab_id":"69ad52a3de79e566650fb76c","country":"PL","accr_number":"AB 1437","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Zawartość tłuszczu Zakres: (1,5 – 6,0) % Metoda spektrometrii w podczerwieni","methodology_en":"Fat content Range: (1,5 – 6,0) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tłuszczu Zakres: (1,5 – 6,0) % Metoda spektrometrii w podczerwieni","reference":"PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7","norm_bases":["PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Zawartość tłuszczu Zakres: (1,5 – 6,0) % Metoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7 Mleko surowe krowie Zawartosc tluszczu Zakres: (1,5 – 6,0) % Metoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Fat content Range: (1,5 – 6,0) % Infrared spectrometry method PN-ISO 9622: 2015-09 using the Milkoscan 7 instrument","search_zh":"生鲜牛乳 脂肪含量 范围：(1,5 – 6,0) % 红外光谱法 PN-ISO 9622: 2015-09 使用Milkoscan 7仪器","test_object_zh":"生鲜牛乳","methodology_de":"Fettgehalt Bereich: (1,5 – 6,0) % Infrarotspektrometrie","search_de":"Kuhrohmilch Fettgehalt Bereich: (1,5 – 6,0) % Infrarotspektrometrie PN-ISO 9622: 2015-09 unter Verwendung des Geräts Milkoscan 7","test_object_de":"Kuhrohmilch","methodology_zh":"脂肪含量 范围：(1,5 – 6,0) % 红外光谱法","reference_en":"PN-ISO 9622: 2015-09 using the Milkoscan 7 instrument","reference_de":"PN-ISO 9622: 2015-09 unter Verwendung des Geräts Milkoscan 7","reference_zh":"PN-ISO 9622: 2015-09 使用Milkoscan 7仪器","search_cs":"Syrové kravské mléko Obsah tuku Rozsah: (1,5 – 6,0) % Metoda infračervené spektrometrie PN-ISO 9622: 2015-09 s použitím přístroje Milkoscan 7","test_object_cs":"Syrové kravské mléko","methodology_cs":"Obsah tuku Rozsah: (1,5 – 6,0) % Metoda infračervené spektrometrie","reference_cs":"PN-ISO 9622: 2015-09 s použitím přístroje Milkoscan 7"},{"_id":"6a5a55fb9af9f73f38252c70","lab_id":"69ad52a3de79e566650fb76c","country":"PL","accr_number":"AB 1437","accr_body":"PCA","test_object":"Mleko surowe krowie","test_object_en":"Raw cows' milk","methodology":"Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni","methodology_en":"Protein content Range: (2,0 – 5,0) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni","reference":"PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7","norm_bases":["PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe krowie Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7 Mleko surowe krowie Zawartosc bialka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu Milkoscan 7","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw cows' milk Protein content Range: (2,0 – 5,0) % Infrared spectrometry method PN-ISO 9622: 2015-09 using the Milkoscan 7 instrument","search_zh":"生鲜牛乳 蛋白质含量 范围：(2,0 – 5,0) % 红外光谱法 PN-ISO 9622: 2015-09 使用Milkoscan 7仪器","test_object_zh":"生鲜牛乳","methodology_de":"Proteingehalt Bereich: (2,0 – 5,0) % Infrarotspektrometrie","search_de":"Kuhrohmilch Proteingehalt Bereich: (2,0 – 5,0) % Infrarotspektrometrie PN-ISO 9622: 2015-09 unter Verwendung des Geräts Milkoscan 7","test_object_de":"Kuhrohmilch","methodology_zh":"蛋白质含量 范围：(2,0 – 5,0) % 红外光谱法","reference_en":"PN-ISO 9622: 2015-09 using the Milkoscan 7 instrument","reference_de":"PN-ISO 9622: 2015-09 unter Verwendung des Geräts Milkoscan 7","reference_zh":"PN-ISO 9622: 2015-09 使用Milkoscan 7仪器","search_cs":"Syrové kravské mléko Obsah bílkovin Rozsah: (2,0 – 5,0) % Metoda infračervené spektrometrie PN-ISO 9622: 2015-09 s použitím přístroje Milkoscan 7","test_object_cs":"Syrové kravské mléko","methodology_cs":"Obsah bílkovin Rozsah: (2,0 – 5,0) % Metoda infračervené spektrometrie","reference_cs":"PN-ISO 9622: 2015-09 s použitím přístroje Milkoscan 7"}],"has_pdf":true}