{"lab":{"_id":"69ad52a3de79e566650fb740","accr_number":"AB 1409","country":"PL","accr_body":"PCA","address":"ul. Dominikańska 8/2, 98-200 Sieradz","categories":["environment"],"city":"Sieradz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"TQMD DUDCZAK ARKADIUSZ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1409.pdf"],"scope_summary":"","search_text":"tqmd dudczak arkadiusz ul. dominikańska 8/2, 98-200 sieradz other environment metrology","status":"active","updated_at":"2026-03-08T14:50:34.384Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:34.384Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201409,podmiot.html","parse_date":"2026-07-17T16:19:05.884Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/36","pl":"Badania chemiczne gazów odlotowych","en":"Chemical tests of waste gases"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise),"},{"codes":"N/36","pl":"Badania właściwości fizycznych gazów odlotowych","en":"Tests of physical properties of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"13","date":"13.01.2025"},"map_coord":[51.595562,18.739372],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":5,"other":5},"category_scores":{"environment":2.5,"other":2.5},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f3825284d","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量 皮托管法"},{"_id":"6a5a55f99af9f73f3825284e","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f99af9f73f3825284f","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 - 9,0) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 - 9,0) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 - 9,0) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 - 9,0) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 - 9,0) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 - 9,0) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252850","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55f99af9f73f38252851","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla, tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, tlenu Zakres: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR - O (3 - 21) % 2 Metoda elektrochemiczna","methodology_en":"Concentration of carbon monoxide, nitrogen monoxide, nitrogen dioxide, sulphur dioxide, carbon dioxide, oxygen Range: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Non-dispersive infrared spectrometry method NDIR - O (3 - 21) % 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla, tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, tlenu Zakres: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR - O (3 - 21) % 2 Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla, tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, tlenu Zakres: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR - O (3 - 21) % 2 Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku wegla, tlenku azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku wegla, tlenu Zakres: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR - O (3 - 21) % 2 Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of carbon monoxide, nitrogen monoxide, nitrogen dioxide, sulphur dioxide, carbon dioxide, oxygen Range: - CO (5 - 600) mg/m3 - NO (5 - 600) mg/m3 - NO (8 - 40) mg/m3 2 - SO (10 - 1380) mg/m3 2 - CO (0,5 - 15) % 2 Non-dispersive infrared spectrometry method NDIR - O (3 - 21) % 2 Electrochemical method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252852","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO , SO , CO, NO, NO (NO 2 2 x i NO w przeliczeniu na NO ) 2 2 (z obliczeń)","methodology_en":"Emission of CO , SO , CO, NO, NO (NO 2 2 x and NO calculated as NO ) 2 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO , SO , CO, NO, NO (NO 2 2 x i NO w przeliczeniu na NO ) 2 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO , SO , CO, NO, NO (NO 2 2 x i NO w przeliczeniu na NO ) 2 2 (z obliczeń) Gazy odlotowe Emisja CO , SO , CO, NO, NO (NO 2 2 x i NO w przeliczeniu na NO ) 2 2 (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of CO , SO , CO, NO, NO (NO 2 2 x and NO calculated as NO ) 2 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252853","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego / żelu krzemionkowego","methodology_en":"Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon / silica gel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego / żelu krzemionkowego","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego / żelu krzemionkowego PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych Metoda aspiracyjna z zastosowaniem wegla aktywnego / zelu krzemionkowego PN-Z-04008-4:1999","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon / silica gel PN-Z-04008-4:1999","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252854","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated)","search_zh":"废气 有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5a55f99af9f73f38252855","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (25 - 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (25 - 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (25 - 135) dB Metoda pomiarowa bezpośrednia","reference":"nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem p. F","norm_bases":["nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem p. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (25 - 135) dB Metoda pomiarowa bezpośrednia nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem p. F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (25 - 135) dB Metoda pomiarowa bezposrednia nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem p. F","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (25 - 135) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem p. F","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 范围：(25 - 135) dB 直接测量法 nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem p. F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"A 计权等效声级 范围：(25 - 135) dB 直接测量法"},{"_id":"6a5a55f99af9f73f38252856","lab_id":"69ad52a3de79e566650fb740","country":"PL","accr_number":"AB 1409","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）"}],"has_pdf":true}