{"lab":{"_id":"69ad52a3de79e566650fb73c","accr_number":"AB 1407","country":"PL","accr_body":"PCA","address":"ul. Akademicka 2a, 44-100 Gliwice, ZESPÓŁ BADAŃ TERENOWYCH, ul. Akademicka 5","categories":["environment","construction"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"POLITECHNIKA ŚLĄSKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1407.pdf"],"scope_summary":"","search_text":"politechnika śląska ul. akademicka 2a, 44-100 gliwice, zespół badań terenowych, ul. akademicka 5 construction metrology food other pharma environment","status":"active","updated_at":"2026-03-08T14:50:34.229Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:25:02.138Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201407,podmiot.html","parse_date":"2026-08-17T10:25:02.138Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/5","pl":"Badania drgań ­ obiekty budowlane","en":"Vibration tests ­ building items"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"J/5","pl":"Badania mechaniczne obiektów budowlanych","en":"Mechanical tests of building items"}],"issue":{"no":"13","date":"26.03.2026"},"map_coord":[50.290102,18.676813],"map_geo":"nominatim-street","lab_locations":[{"name":"ZESPÓŁ BADAŃ TERENOWYCH","address":"ul. Akademicka 5","city":"Gliwice","postal":"44-100"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/776fd8758fd86bcf1005037ec5b01ad9/AB%201407.pdf","has_en":true,"category_counts":{"environment":8,"construction":7,"other":2},"category_scores":{"environment":3.76,"construction":2.88,"other":0.24},"has_zh":true},"methods":[{"_id":"6a82e17e884ede9a1b2c37a5","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przemieszczeń przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"do 100 mm"},{"name":"Pomiar z zastosowaniem czujników mechanicznych i indukcyjnych"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przemieszczeń przy obciążeniu statycznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujników mechanicznych i indukcyjnych","reference":"PB­01 wydanie 7 z dnia 15.03.2015 r.","norm_bases":["PB­01 wydanie 7 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń przy obciążeniu statycznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujników mechanicznych i indukcyjnych PB­01 wydanie 7 z dnia 15.03.2015 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen przy obciazeniu statycznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujnikow mechanicznych i indukcyjnych PB­01 wydanie 7 z dnia 15.03.2015 r.","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"do 100 mm"},{"name":"Pomiar z zastosowaniem czujników mechanicznych i indukcyjnych"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Range PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"do 100 mm"},{"name":"Pomiar z zastosowaniem czujników mechanicznych i indukcyjnych"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 范围 PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）"},{"_id":"6a82e17e884ede9a1b2c37a6","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar osiadań i przemieszczeń przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"do 300 mm"},{"name":"Pomiar z zastosowaniem niwelacji precyzyjnej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar osiadań i przemieszczeń przy obciążeniu statycznym\nZakres:\nZakres do 300 mm\nPomiar z zastosowaniem niwelacji precyzyjnej","reference":"PB­01 wydanie 7 z dnia 15.03.2015 r.","norm_bases":["PB­01 wydanie 7 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar osiadań i przemieszczeń przy obciążeniu statycznym\nZakres:\nZakres do 300 mm\nPomiar z zastosowaniem niwelacji precyzyjnej PB­01 wydanie 7 z dnia 15.03.2015 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar osiadan i przemieszczen przy obciazeniu statycznym\nZakres:\nZakres do 300 mm\nPomiar z zastosowaniem niwelacji precyzyjnej PB­01 wydanie 7 z dnia 15.03.2015 r.","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"do 300 mm"},{"name":"Measurement using precise levelling"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Range Measurement using precise levelling PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"do 300 mm"},{"name":"采用精密水准测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 范围 采用精密水准测量的测定 PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）"},{"_id":"6a82e17e884ede9a1b2c37a7","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar osiadania podpór przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"do 50 mm"},{"name":"Pomiar z zastosowaniem niwelacji precyzyjnej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar osiadania podpór przy obciążeniu statycznym\nZakres:\nZakres do 50 mm\nPomiar z zastosowaniem niwelacji precyzyjnej","reference":"PB­01 wydanie 7 z dnia 15.03.2015 r.","norm_bases":["PB­01 wydanie 7 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar osiadania podpór przy obciążeniu statycznym\nZakres:\nZakres do 50 mm\nPomiar z zastosowaniem niwelacji precyzyjnej PB­01 wydanie 7 z dnia 15.03.2015 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar osiadania podpor przy obciazeniu statycznym\nZakres:\nZakres do 50 mm\nPomiar z zastosowaniem niwelacji precyzyjnej PB­01 wydanie 7 z dnia 15.03.2015 r.","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Measurement of support settlement under static load","parameters_en":[{"name":"Range","range":"do 50 mm"},{"name":"Measurement using precise levelling"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of support settlement under static load Range Measurement using precise levelling PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"do 50 mm"},{"name":"采用精密水准测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静荷载下支座沉降的测量 范围 采用精密水准测量的测定 PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"静荷载下支座沉降的测量"},{"_id":"6a82e17e884ede9a1b2c37a8","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar ugięcia przęseł przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"(0 ­ 300) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar ugięcia przęseł przy obciążeniu statycznym\nZakres (0 ­ 300) mm","reference":"PB­01 wydanie 7 z dnia 15.03.2015 r.","norm_bases":["PB­01 wydanie 7 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar ugięcia przęseł przy obciążeniu statycznym\nZakres (0 ­ 300) mm PB­01 wydanie 7 z dnia 15.03.2015 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar ugiecia przesel przy obciazeniu statycznym\nZakres (0 ­ 300) mm PB­01 wydanie 7 z dnia 15.03.2015 r.","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 ­ 300) mm"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Range PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"(0 ­ 300) mm"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 范围 PB­01 wydanie 7 z dnia 15.03.2015 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）"},{"_id":"6a82e17e884ede9a1b2c37a9","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym","parameters":[{"name":"Zakres","range":"do 100 mm"},{"name":"Pomiar z zastosowaniem czujników przemieszczeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujników przemieszczeń","reference":"PN­89/S­10050 | PN­S­10040:1999","norm_bases":["PN­89/S­10050","PN­S­10040:1999"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujników przemieszczeń PN­89/S­10050 | PN­S­10040:1999 Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu dynamicznym\nZakres:\nZakres do 100 mm\nPomiar z zastosowaniem czujnikow przemieszczen PN­89/S­10050 | PN­S­10040:1999","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Measurement of vertical displacements under dynamic loading","parameters_en":[{"name":"Range","range":"do 100 mm"},{"name":"Measurement using displacement sensors"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under dynamic loading Range Measurement using displacement sensors PN­89/S­10050 | PN­S­10040:1999","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"do 100 mm"},{"name":"采用位移传感器的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下的竖向位移测量 范围 采用位移传感器的测定 PN­89/S­10050 | PN­S­10040:1999","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"动荷载下的竖向位移测量"},{"_id":"6a82e17e884ede9a1b2c37aa","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane","methodology":"Pomiar przyspieszeń","parameters":[{"name":"Zakres","range":"amplituda ±50 m/s2"},{"name":"częstotliwość","range":"0,5÷200 Hz"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przyspieszeń\nZakres:\nZakres amplituda ±50 m/s2\nczęstotliwość 0,5÷200 Hz","reference":"PB­02 wydanie 1 z dnia 15.03.2015 r.","norm_bases":["PB­02 wydanie 1 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane Pomiar przyspieszeń\nZakres:\nZakres amplituda ±50 m/s2\nczęstotliwość 0,5÷200 Hz PB­02 wydanie 1 z dnia 15.03.2015 r. Obiekty budowlane Pomiar przyspieszen\nZakres:\nZakres amplituda ±50 m/s2\nczestotliwosc 0,5÷200 Hz PB­02 wydanie 1 z dnia 15.03.2015 r.","categories":["construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"amplituda ±50 m/s2"},{"name":"frequency","range":"0,5÷200 Hz"}],"search_en":"Construction works Range frequency PB­02 wydanie 1 z dnia 15.03.2015 r.","test_object_en":"Construction works","parameters_zh":[{"name":"范围","range":"amplituda ±50 m/s2"},{"name":"częstotliwość","range":"0,5÷200 Hz"}],"search_zh":"建筑物与构筑物 范围 PB­02 wydanie 1 z dnia 15.03.2015 r.","test_object_zh":"建筑物与构筑物"},{"_id":"6a82e17e884ede9a1b2c37ab","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Obiekty budowlane","methodology":"Pomiar odkształceń i naprężeń za pomocą tensometrii elektrooporowej","parameters":[{"name":"Zakres","range":"amplituda ±2000 µm/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar odkształceń i naprężeń za pomocą tensometrii elektrooporowej\nZakres amplituda ±2000 µm/m","reference":"PB­03 wydanie 1 z dnia 15.03.2015 r.","norm_bases":["PB­03 wydanie 1 z dnia 15.03.2015 r."],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane Pomiar odkształceń i naprężeń za pomocą tensometrii elektrooporowej\nZakres amplituda ±2000 µm/m PB­03 wydanie 1 z dnia 15.03.2015 r. Obiekty budowlane Pomiar odksztalcen i naprezen za pomoca tensometrii elektrooporowej\nZakres amplituda ±2000 µm/m PB­03 wydanie 1 z dnia 15.03.2015 r.","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"amplituda ±2000 µm/m"}],"search_en":"Construction works Range PB­03 wydanie 1 z dnia 15.03.2015 r.","test_object_en":"Construction works","parameters_zh":[{"name":"范围","range":"amplituda ±2000 µm/m"}],"search_zh":"建筑物与构筑物 范围 PB­03 wydanie 1 z dnia 15.03.2015 r.","test_object_zh":"建筑物与构筑物"},{"_id":"6a82e17e884ede9a1b2c37ac","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Budynki i budowle","methodology":"Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych","parameters":[{"name":"Zakres częstotliwości","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"technique":null,"techniques":[],"computed":[],"activity":"Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości (0,5 – 200)Hz\nZakres przyśpieszeń ±10 m/s2 pk","reference":"PN­B­02170:1985 | PN­B­02170:2016­12","norm_bases":["PN­B­02170:1985","PN­B­02170:2016­12"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Budynki i budowle Wartość maksymalna przyspieszenia drgań w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości (0,5 – 200)Hz\nZakres przyśpieszeń ±10 m/s2 pk PN­B­02170:1985 | PN­B­02170:2016­12 Budynki i budowle Wartosc maksymalna przyspieszenia drgan w pasmach 1/3 oktawowych\nZakres:\nZakres czestotliwosci (0,5 – 200)Hz\nZakres przyspieszen ±10 m/s2 pk PN­B­02170:1985 | PN­B­02170:2016­12","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Maximum value of vibration acceleration in 1/3 octave bands","parameters_en":[{"name":"Frequency range","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"search_en":"Buildings and structures Maximum value of vibration acceleration in 1/3 octave bands Frequency range PN­B­02170:1985 | PN­B­02170:2016­12","test_object_en":"Buildings and structures","parameters_zh":[{"name":"频率范围","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"search_zh":"建筑物与构筑物 频率范围 PN­B­02170:1985 | PN­B­02170:2016­12","test_object_zh":"建筑物与构筑物"},{"_id":"6a82e17e884ede9a1b2c37ad","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Pomieszczenia w budynkach","methodology":"Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych","parameters":[{"name":"Zakres częstotliwości","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"technique":null,"techniques":[],"computed":[],"activity":"Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości (0,5 – 200)Hz\nZakres przyśpieszeń ±10 m/s2 pk","reference":"PN­B­02171:1988 | PN­B­02171:2017­06","norm_bases":["PN­B­02171:1988","PN­B­02171:2017­06"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach Wartość skuteczna przyspieszenia drgań w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości (0,5 – 200)Hz\nZakres przyśpieszeń ±10 m/s2 pk PN­B­02171:1988 | PN­B­02171:2017­06 Pomieszczenia w budynkach Wartosc skuteczna przyspieszenia drgan w pasmach 1/3 oktawowych\nZakres:\nZakres czestotliwosci (0,5 – 200)Hz\nZakres przyspieszen ±10 m/s2 pk PN­B­02171:1988 | PN­B­02171:2017­06","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"RMS value of vibration acceleration in 1/3 octave bands","parameters_en":[{"name":"Frequency range","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"search_en":"Rooms in buildings RMS value of vibration acceleration in 1/3 octave bands Frequency range PN­B­02171:1988 | PN­B­02171:2017­06","test_object_en":"Rooms in buildings","parameters_zh":[{"name":"频率范围","range":"(0,5 – 200)Hz"},{"name":"Zakres przyśpieszeń","range":"±10 m/s2 pk"}],"search_zh":"建筑物内的房间 频率范围 PN­B­02171:1988 | PN­B­02171:2017­06","test_object_zh":"建筑物内的房间"},{"_id":"6a82e17e884ede9a1b2c37ae","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – ekrany akustyczne „in situ”","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"PN­ISO 10847:2002","norm_bases":["PN­ISO 10847:2002"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – ekrany akustyczne „in situ” Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia PN­ISO 10847:2002 Srodowisko ogolne – ekrany akustyczne „in situ” Rownowazny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia PN­ISO 10847:2002","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"search_en":"General environment – noise barriers „in situ” A-weighted equivalent sound pressure level Direct measurement method Range PN­ISO 10847:2002","technique_en":"Direct measurement method","test_object_en":"General environment – noise barriers „in situ”","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 － 声屏障「现场」 A 计权等效声级 直接测量法 范围 PN­ISO 10847:2002","technique_zh":"直接测量法","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a82e17e884ede9a1b2c37af","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – ekrany akustyczne „in situ”","methodology":"Skuteczność ekranów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność ekranów (z obliczeń)","reference":"PN­ISO 10847:2002","norm_bases":["PN­ISO 10847:2002"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – ekrany akustyczne „in situ” Skuteczność ekranów (z obliczeń) PN­ISO 10847:2002 Srodowisko ogolne – ekrany akustyczne „in situ” Skutecznosc ekranow (z obliczen) PN­ISO 10847:2002","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effectiveness of screens (calculated)","search_en":"General environment – noise barriers „in situ” Effectiveness of screens (calculated) PN­ISO 10847:2002","test_object_en":"General environment – noise barriers „in situ”","methodology_zh":"屏蔽效能（由计算得出）","search_zh":"一般环境 － 声屏障「现场」 屏蔽效能（由计算得出） PN­ISO 10847:2002","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a82e17e884ede9a1b2c37b0","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a82e17e884ede9a1b2c37b1","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ekspozycyjny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权声暴露级"},{"_id":"6a82e17e884ede9a1b2c37b2","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from roads, railway lines, tram lines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","test_object_en":"General environment – noise from roads, railway lines, tram lines","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. nr 140, poz. 824 i nr 288, poz. 1697)","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"},{"_id":"6a82e17e884ede9a1b2c37b3","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"PN ISO 9613­2:2002","norm_bases":["PN ISO 9613­2:2002"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613­2:2002 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613­2:2002","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from roads, railway lines, tram lines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method PN ISO 9613­2:2002","technique_en":"Calculation method","test_object_en":"General environment – noise from roads, railway lines, tram lines","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 PN ISO 9613­2:2002","technique_zh":"计算法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"},{"_id":"6a82e17e884ede9a1b2c37b4","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7 wrzesnia 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82e17e884ede9a1b2c37b5","lab_id":"69ad52a3de79e566650fb73c","country":"PL","accr_number":"AB 1407","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Zespół Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7 wrzesnia 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (tj. Dz.U. z 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"}],"has_pdf":true}