{"lab":{"_id":"69ad52a3de79e566650fb738","accr_number":"AB 1403","country":"PL","accr_body":"PCA","address":"ANNA SKOWROŃSKA-KANELLAKI, ul. Długa 28, 62-811 Kościelna Wieś, LABORATORIUM, ul. Dobrzecka 69/71, 62-800 Kalisz","categories":["environment","construction"],"city":"Kalisz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":19,"name":"HP.LAB","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1403.pdf"],"scope_summary":"","search_text":"hp.lab anna skowrońska-kanellaki, ul. długa 28, 62-811 kościelna wieś, laboratorium, ul. dobrzecka 69/71, 62-800 kalisz other environment metrology materials construction electronics","status":"active","updated_at":"2026-03-08T14:50:34.124Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:34.124Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201403,podmiot.html","parse_date":"2026-07-17T16:19:05.745Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling – working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors – air)"}],"issue":{"no":"13","date":"09.10.2025"},"map_coord":[51.782508,18.09542],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":19,"construction":2,"materials":1},"category_scores":{"environment":16.41,"construction":0.18,"materials":0.05},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f382527f1","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (50 – 140) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (50 – 140) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (50 – 140) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p.11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p.11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (50 – 140) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p.11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C Zakres: (50 – 140) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 p. 10 i Strategie 3 - p.11","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – noise A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (50 – 140) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p.11","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p.11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55f99af9f73f382527f2","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – noise Noise exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","search_zh":"工作场所环境 — 噪声","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55f99af9f73f382527f3","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (5 – 5000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (5 – 5000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (5 – 5000) lx Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r.","norm_bases":["PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (5 – 5000) lx Metoda pomiarowa bezpośrednia PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (5 – 5000) lx Metoda pomiarowa bezposrednia PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r.","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – indoor electric lighting Illuminance Range: (5 – 5000) lx Direct measurement method PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r.","search_zh":"工作场所环境 — 室内电气照明 照度 范围：(5 – 5000) lx 直接测量法 PN-83/E-04040.03 PB-05 wydanie 2 z dnia 02.02.2019 r.","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度 范围：(5 – 5000) lx 直接测量法"},{"_id":"6a5a55f99af9f73f382527f4","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55f99af9f73f382527f5","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe − frakcja wdychalna − frakcja respirabilna - substancje organiczne, w tym − frakcja wdychalna - substancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna - metale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - dust agents − inhalable fraction − respirable fraction - organic substances, including − inhalable fraction - inorganic substances, including − inhalable fraction − respirable fraction - metals and their compounds, including − inhalable fraction − respirable fraction Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe − frakcja wdychalna − frakcja respirabilna - substancje organiczne, w tym − frakcja wdychalna - substancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna - metale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe − frakcja wdychalna − frakcja respirabilna - substancje organiczne, w tym − frakcja wdychalna - substancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna - metale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na: - czynniki pylowe − frakcja wdychalna − frakcja respirabilna - substancje organiczne, w tym − frakcja wdychalna - substancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna - metale i ich zwiazki, w tym − frakcja wdychalna − frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Sampling for occupational exposure assessment to: - dust agents − inhalable fraction − respirable fraction - organic substances, including − inhalable fraction - inorganic substances, including − inhalable fraction − respirable fraction - metals and their compounds, including − inhalable fraction − respirable fraction Personal dosimetry method PN-Z-04008-7:2002+Az1:2004","search_zh":"工作场所环境 — 空气 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f99af9f73f382527f6","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f99af9f73f382527f7","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,1 – 20,4) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents - inhalable fraction: - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,1 – 20,4) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,1 – 20,4) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,1 – 20,4) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna: - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyly drewna - Pyly maki - Pyly niesklasyfikowane ze wzgledu na toksycznosc - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Wegiel (kamienny, brunatny) - Weglan magnezu wapnia (dolomit) - Weglik krzemu, niewloknisty Zakres: (0,1 – 20,4) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,1 – 20,4) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f99af9f73f382527f8","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,1 – 7,3) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents - respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) Range: (0,1 – 7,3) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,1 – 7,3) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,1 – 7,3) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Talk - Wegiel (kamienny, brunatny) Zakres: (0,1 – 7,3) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) Range: (0,1 – 7,3) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f99af9f73f382527f9","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie gazów: Zakres: - CO (2,32− 232) mg/m3 (2 - 200) ppm Metoda elektrochemiczna","methodology_en":"Gas concentration: Range: - CO (2,32− 232) mg/m3 (2 - 200) ppm Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie gazów: Zakres: - CO (2,32− 232) mg/m3 (2 - 200) ppm Metoda elektrochemiczna","reference":"PB-02 wydanie 3 z dnia 02.07.2025 r.","norm_bases":["PB-02 wydanie 3 z dnia 02.07.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie gazów: Zakres: - CO (2,32− 232) mg/m3 (2 - 200) ppm Metoda elektrochemiczna PB-02 wydanie 3 z dnia 02.07.2025 r. Srodowisko pracy – powietrze Stezenie gazow: Zakres: - CO (2,32− 232) mg/m3 (2 - 200) ppm Metoda elektrochemiczna PB-02 wydanie 3 z dnia 02.07.2025 r.","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Gas concentration: Range: - CO (2,32− 232) mg/m3 (2 - 200) ppm Electrochemical method PB-02 wydanie 3 z dnia 02.07.2025 r.","search_zh":"工作场所环境 — 空气 PB-02 wydanie 3 z dnia 02.07.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f99af9f73f382527fa","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,07 – 120) m/s2 Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted effective vibration acceleration Range: (0,07 – 120) m/s2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,07 – 120) m/s2 Metoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,07 – 120) m/s2 Metoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,07 – 120) m/s2 Metoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,07 – 120) m/s2 Direct measurement method PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5a55f99af9f73f382527fb","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a wx,, 1,4a , a ,) wy wz Ekspozycja trwająca 30 min i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a 1,4a , a ) wx, wy wz (z obliczeń)","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a wx,, 1,4a , a ,) wy wz Exposure lasting 30 min and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a 1,4a , a ) wx, wy wz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a wx,, 1,4a , a ,) wy wz Ekspozycja trwająca 30 min i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a 1,4a , a ) wx, wy wz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a wx,, 1,4a , a ,) wy wz Ekspozycja trwająca 30 min i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4a 1,4a , a ) wx, wy wz (z obliczeń) Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4a wx,, 1,4a , a ,) wy wz Ekspozycja trwajaca 30 min i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4a 1,4a , a ) wx, wy wz (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a wx,, 1,4a , a ,) wy wz Exposure lasting 30 min and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a 1,4a , a ) wx, wy wz (calculated)","search_zh":"工作场所环境 — 全身振动","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5a55f99af9f73f382527fc","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,3 – 500) m/s2 Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted r.m.s. vibration acceleration Range: (0,3 – 500) m/s2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,3 – 500) m/s2 Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,3 – 500) m/s2 Metoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,3 – 500) m/s2 Metoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Range: (0,3 – 500) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5a55f99af9f73f382527fd","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a hwx, a , a ) hwy hwz Ekspozycja trwajaca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a a , a ) hwx, hwy hwz (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (a hwx, a , a ) hwy hwz Exposure lasting 30 minutes or less expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a a , a ) hwx, hwy hwz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a hwx, a , a ) hwy hwz Ekspozycja trwajaca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a a , a ) hwx, hwy hwz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a hwx, a , a ) hwy hwz Ekspozycja trwajaca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a a , a ) hwx, hwy hwz (z obliczeń) Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a hwx, a , a ) hwy hwz Ekspozycja trwajaca 30 minut i krocej wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a a , a ) hwx, hwy hwz (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (a hwx, a , a ) hwy hwz Exposure lasting 30 minutes or less expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (a a , a ) hwx, hwy hwz (calculated)","search_zh":"工作场所环境 — 手传振动","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5a55f99af9f73f382527fe","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Temperatura powietrza Zakres: (20 – 55) °C Temperatura wilgotna naturalna Zakres: (20 – 55) °C Temperatura poczernionej kuli Zakres: (20 – 55) °C Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (20 – 55) °C Natural wet bulb temperature Range: (20 – 55) °C Blackened globe temperature Range: (20 – 55) °C Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (20 – 55) °C Temperatura wilgotna naturalna Zakres: (20 – 55) °C Temperatura poczernionej kuli Zakres: (20 – 55) °C Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza Zakres: (20 – 55) °C Temperatura wilgotna naturalna Zakres: (20 – 55) °C Temperatura poczernionej kuli Zakres: (20 – 55) °C Metoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza Zakres: (20 – 55) °C Temperatura wilgotna naturalna Zakres: (20 – 55) °C Temperatura poczernionej kuli Zakres: (20 – 55) °C Metoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − hot microclimate Air temperature Range: (20 – 55) °C Natural wet bulb temperature Range: (20 – 55) °C Blackened globe temperature Range: (20 – 55) °C Direct measurement method PN-EN ISO 7243:2018-01","search_zh":"工作场所环境 − 高温微气候 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a5a55f99af9f73f382527ff","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń) Srodowisko pracy − mikroklimat goracy Wskaznik WBGT Wskaznik WBGTeff (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − hot microclimate WBGT index WBGTeff index (calculated)","search_zh":"工作场所环境 − 高温微气候 WBGT 指数 WBGTeff 指数（由计算得出）","test_object_zh":"工作场所环境 − 高温微气候","methodology_zh":"WBGT 指数 WBGTeff 指数（由计算得出）"},{"_id":"6a5a55f99af9f73f38252800","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Temperatura powietrza Zakres: (10 - 30) °C Temperatura poczernionej kuli Zakres: (10 - 40) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 1) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 - 30) °C Blackened globe temperature Range: (10 - 40) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 1) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 - 30) °C Temperatura poczernionej kuli Zakres: (10 - 40) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 1) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza Zakres: (10 - 30) °C Temperatura poczernionej kuli Zakres: (10 - 40) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 1) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza Zakres: (10 - 30) °C Temperatura poczernionej kuli Zakres: (10 - 40) °C Wilgotnosc powietrza Zakres: (25 – 75) % Predkosc powietrza Zakres: (0,15 – 1) m/s Metoda pomiarowa bezposrednia PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − moderate microclimate Air temperature Range: (10 - 30) °C Blackened globe temperature Range: (10 - 40) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 1) m/s Direct measurement method PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","search_zh":"工作场所环境 − 中等微气候 PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a5a55f99af9f73f38252801","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV Wskaźnik PPD (z obliczeń) Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV Wskaznik PPD (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − moderate microclimate PMV index PPD index (calculated)","search_zh":"工作场所环境 − 中等微气候 PMV 指数 PPD 指数（计算值）","test_object_zh":"工作场所环境 − 中等微气候","methodology_zh":"PMV 指数 PPD 指数（计算值）"},{"_id":"6a5a55f99af9f73f38252802","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","test_object_en":"Workplace environment − cold microclimate","methodology":"Temperatura powietrza Zakres: (-20 - 10) °C Temperatura poczernionej kuli Zakres: (-20 - 10) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,4 – 5) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (-20 - 10) °C Blackened globe temperature Range: (-20 - 10) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,4 – 5) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (-20 - 10) °C Temperatura poczernionej kuli Zakres: (-20 - 10) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,4 – 5) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza Zakres: (-20 - 10) °C Temperatura poczernionej kuli Zakres: (-20 - 10) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,4 – 5) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza Zakres: (-20 - 10) °C Temperatura poczernionej kuli Zakres: (-20 - 10) °C Wilgotnosc powietrza Zakres: (25 – 75) % Predkosc powietrza Zakres: (0,4 – 5) m/s Metoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − cold microclimate Air temperature Range: (-20 - 10) °C Blackened globe temperature Range: (-20 - 10) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,4 – 5) m/s Direct measurement method PN-EN ISO 11079:2008","search_zh":"工作场所环境 − 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a5a55f99af9f73f38252803","lab_id":"69ad52a3de79e566650fb738","country":"PL","accr_number":"AB 1403","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","test_object_en":"Workplace environment − cold microclimate","methodology":"Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń)","methodology_en":"IREQ min index IREQ neutral index t wc index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń) Srodowisko pracy − mikroklimat zimny Wskaznik IREQ min Wskaznik IREQ neutral Wskaznik t wc (z obliczen)","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − cold microclimate IREQ min index IREQ neutral index t wc index (calculated)","search_zh":"工作场所环境 − 低温微气候 IREQ min 指数 IREQ neutral 指数 t wc 指数（由计算得出）","test_object_zh":"工作场所环境 − 低温微气候","methodology_zh":"IREQ min 指数 IREQ neutral 指数 t wc 指数（由计算得出）"}],"has_pdf":true}