{"lab":{"_id":"69ad52a3de79e566650fb71c","accr_number":"AB 1383","country":"PL","accr_body":"PCA","address":"LABORATORIUM JAKOŚCI, Al. Tysiąclecia Państwa Polskiego 13, 24-110 Puławy","categories":["petro","environment"],"city":"Puławy","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"GRUPA AZOTY ZAKŁADY AZOTOWE „PUŁAWY” S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1383.pdf"],"scope_summary":"","search_text":"grupa azoty zakłady azotowe „puławy” s.a. laboratorium jakości, al. tysiąclecia państwa polskiego 13, 24-110 puławy materials petro other environment","status":"active","updated_at":"2026-03-08T14:50:33.273Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:33.273Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201383,podmiot.html","parse_date":"2026-07-17T16:19:05.446Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych i odpadów","en":"Chemical tests of solid fuels and waste"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"}],"issue":{"no":"13","date":"29.11.2024"},"map_coord":[51.450645,21.984209],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":11,"environment":1},"category_scores":{"petro":10.08,"environment":0.08},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f3825271f","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci I stopnia (wilgoci przemijającej) Zakres: (1,0 - 16,0) % Metoda wagowa","methodology_en":"First-stage moisture content (transient moisture) Range: (1,0 - 16,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci I stopnia (wilgoci przemijającej) Zakres: (1,0 - 16,0) % Metoda wagowa","reference":"PN-80/G-04511 PN-ISO 589:2006","norm_bases":["PN-80/G-04511 PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci I stopnia (wilgoci przemijającej) Zakres: (1,0 - 16,0) % Metoda wagowa PN-80/G-04511 PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci I stopnia (wilgoci przemijajacej) Zakres: (1,0 - 16,0) % Metoda wagowa PN-80/G-04511 PN-ISO 589:2006","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal First-stage moisture content (transient moisture) Range: (1,0 - 16,0) % Gravimetric method PN-80/G-04511 PN-ISO 589:2006","search_zh":"固体燃料：烟煤 PN-80/G-04511 PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252720","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci II stopnia Zakres: (0,5 - 12,0)% Metoda wagowa","methodology_en":"Second-stage moisture content Range: (0,5 - 12,0)% Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci II stopnia Zakres: (0,5 - 12,0)% Metoda wagowa","reference":"PN-ISO 589:2006 metoda A1 i metoda A2","norm_bases":["PN-ISO 589:2006 metoda A1 i metoda A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci II stopnia Zakres: (0,5 - 12,0)% Metoda wagowa PN-ISO 589:2006 metoda A1 i metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci II stopnia Zakres: (0,5 - 12,0)% Metoda wagowa PN-ISO 589:2006 metoda A1 i metoda A2","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second-stage moisture content Range: (0,5 - 12,0)% Gravimetric method PN-ISO 589:2006 metoda A1 i metoda A2","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 metoda A1 i metoda A2","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252721","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 - 12,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,5 - 12,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 - 12,0) % Metoda wagowa","reference":"PN-80/G-04511 PN-ISO 11722:2009","norm_bases":["PN-80/G-04511 PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,5 - 12,0) % Metoda wagowa PN-80/G-04511 PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,5 - 12,0) % Metoda wagowa PN-80/G-04511 PN-ISO 11722:2009","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,5 - 12,0) % Gravimetric method PN-80/G-04511 PN-ISO 11722:2009","search_zh":"固体燃料：烟煤 PN-80/G-04511 PN-ISO 11722:2009","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252722","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej Zakres: (1,0 - 25,0) % Metoda wagowa","methodology_en":"Total moisture content Range: (1,0 - 25,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (1,0 - 25,0) % Metoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej Zakres: (1,0 - 25,0) % Metoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej Zakres: (1,0 - 25,0) % Metoda wagowa PN-80/G-04511","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content Range: (1,0 - 25,0) % Gravimetric method PN-80/G-04511","search_zh":"固体燃料：烟煤 PN-80/G-04511","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252723","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 metoda A1 i metoda A2","norm_bases":["PN-ISO 589:2006 metoda A1 i metoda A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 metoda A1 i metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 metoda A1 i metoda A2","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 metoda A1 i metoda A2","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 metoda A1 i metoda A2","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55f99af9f73f38252724","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (1,0 - 40,0) % Metoda wagowa","methodology_en":"Ash content Range: (1,0 - 40,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,0 - 40,0) % Metoda wagowa","reference":"PN-80/G-04512+Az1:2002 pkt.2.4.1","norm_bases":["PN-80/G-04512+Az1:2002 pkt.2.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (1,0 - 40,0) % Metoda wagowa PN-80/G-04512+Az1:2002 pkt.2.4.1 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (1,0 - 40,0) % Metoda wagowa PN-80/G-04512+Az1:2002 pkt.2.4.1","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (1,0 - 40,0) % Gravimetric method PN-80/G-04512+Az1:2002 pkt.2.4.1","search_zh":"固体燃料：烟煤 PN-80/G-04512+Az1:2002 pkt.2.4.1","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252725","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (3,5 - 40,0) % Metoda wagowa","methodology_en":"Ash content Range: (3,5 - 40,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (3,5 - 40,0) % Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (3,5 - 40,0) % Metoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (3,5 - 40,0) % Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (3,5 - 40,0) % Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252726","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania Zakres: (17000 - 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (17000 - 35000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (17000 - 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513 PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513 PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania Zakres: (17000 - 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-81/G-04513 PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania Zakres: (17000 - 35000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-81/G-04513 PN-ISO 1928:2020-05","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Gross calorific value Range: (17000 - 35000) kJ/kg Calorimetric method Net calorific value (calculated) PN-81/G-04513 PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤 PN-81/G-04513 PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252727","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,10 – 1,70) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulphur content Range: (0,10 – 1,70) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,10 – 1,70) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,10 – 1,70) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,10 – 1,70) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulphur content Range: (0,10 – 1,70) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252728","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego Zakres: (45,0 - 92,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (45,0 - 92,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (45,0 - 92,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego Zakres: (45,0 - 92,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego Zakres: (45,0 - 92,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total carbon content Range: (45,0 - 92,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f38252729","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru Zakres: (1,50 – 6,00)% Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Hydrogen content Range: (1,50 – 6,00)% High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (1,50 – 6,00)% Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru Zakres: (1,50 – 6,00)% Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru Zakres: (1,50 – 6,00)% Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Hydrogen content Range: (1,50 – 6,00)% High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f99af9f73f3825272a","lab_id":"69ad52a3de79e566650fb71c","country":"PL","accr_number":"AB 1383","accr_body":"PCA","test_object":"Odpadyo): kod 10 01 02 Popiół lotny z węgla kamiennego","test_object_en":"Wasteo): code 10 01 02 Hard coal fly ash","methodology":"Zawartość węgla całkowitego Zakres: (0,3 - 8,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (0,3 - 8,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,3 - 8,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpadyo): kod 10 01 02 Popiół lotny z węgla kamiennego Zawartość węgla całkowitego Zakres: (0,3 - 8,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpadyo): kod 10 01 02 Popiol lotny z wegla kamiennego Zawartosc wegla calkowitego Zakres: (0,3 - 8,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wasteo): code 10 01 02 Hard coal fly ash Total carbon content Range: (0,3 - 8,0) % High-temperature combustion method with IR detection PN-G-04571:1998"}],"has_pdf":true}