{"lab":{"_id":"69ad52a3de79e566650fb708","accr_number":"AB 1371","country":"PL","accr_body":"PCA","address":"STANISŁAW GOGOLIŃSKI, MIROSŁAW PTASZYK, ul. Wypoczynkowa 49/4, 64-300 Nowy Tomyśl, LABORATORIUM PRO-BIT, ul. 3 Stycznia 14","categories":["environment","construction","materials"],"city":"Nowy Tomyśl","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"PRZEDSIĘBIORSTWO PRODUKCYJNO-USŁUGOWE PRO-BIT S.C.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1371.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo produkcyjno-usługowe pro-bit s.c. stanisław gogoliński, mirosław ptaszyk, ul. wypoczynkowa 49/4, 64-300 nowy tomyśl, laboratorium pro-bit, ul. 3 stycznia 14 environment materials other construction electronics metrology","status":"active","updated_at":"2026-03-08T14:50:32.595Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:00:07.894Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201371,podmiot.html","parse_date":"2026-08-13T08:00:07.894Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne):- środowisko pracy (czynniki szkodliwe – hałas i drgania)","en":"Tests concerning environmental engineering (environmental and climatic) of working environment (harmful factors – noise and vibration),"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling of- working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling of working environment (harmful factors - air)"}],"issue":{"no":"16","date":"17.07.2026"},"map_coord":[52.310351,16.13491],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM PRO-BIT","address":"ul. 3 Stycznia 14","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/438b3f9439e9d346ea47fd7fb8e737ac/AB%201371.pdf","has_en":true,"category_counts":{"environment":11,"construction":2,"materials":1},"category_scores":{"environment":8.64,"construction":0.29,"materials":0.07},"has_zh":true},"methods":[{"_id":"6a7d79870636ba417e41aade","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 135,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40,0 – 135,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dzwieku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25,0 – 135,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40,0 – 135,0) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Pro-Bit Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25,0 – 135,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40,0 – 135,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 Pro-Bit 实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aadf","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Pro-Bit Laboratory an 8-hour daily working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： Pro-Bit 实验室 每日 8 小时工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"Pro-Bit 实验室","parameters_zh":[{"name":"每日 8 小时工作时间（由计算得出）"}]},{"_id":"6a7d79870636ba417e41aae0","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 +Az1:2004","norm_bases":["PN-Z-04008-7:2002 +Az1:2004"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 +Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 +Az1:2004","categories":["materials","environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"inorganic substances, including – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method Pro-Bit Laboratory dust agents – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – inhalable fraction – respirable fraction organic substances, including – inhalable fraction PN-Z-04008-7:2002 +Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 Pro-Bit 实验室 粉尘因素 — 可吸入组分 — 呼吸性组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 有机物质，包括 — 可吸入组分 PN-Z-04008-7:2002 +Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘"},{"name":"有机物质，包括 — 可吸入组分"}],"lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae1","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 +Az1:2004","norm_bases":["PN-Z-04008-7:2002 +Az1:2004"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 +Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 +Az1:2004","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method Pro-Bit Laboratory inorganic substances PN-Z-04008-7:2002 +Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 Pro-Bit 实验室 无机物质 PN-Z-04008-7:2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质"}],"technique_zh":"定点测定法","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae2","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 +Az1:2004","norm_bases":["PN-Z-04008-7:2002 +Az1:2004"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 +Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 +Az1:2004","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) Pro-Bit Laboratory PN-Z-04008-7:2002 +Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） Pro-Bit 实验室 PN-Z-04008-7:2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae3","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,17 – 17,00) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17 – 17,00) mg/m3\nMetoda grawimetryczna","reference":"PN-Z- 04507:2022:05 | PN-Z- 04507:2022:05/Ap1:2022:08","norm_bases":["PN-Z- 04507:2022:05","PN-Z- 04507:2022:05/Ap1:2022:08"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17 – 17,00) mg/m3\nMetoda grawimetryczna PN-Z- 04507:2022:05 | PN-Z- 04507:2022:05/Ap1:2022:08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,17 – 17,00) mg/m3\nMetoda grawimetryczna PN-Z- 04507:2022:05 | PN-Z- 04507:2022:05/Ap1:2022:08","categories":["environment","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,17 – 17,00) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Pro-Bit Laboratory Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z- 04507:2022:05 | PN-Z- 04507:2022:05/Ap1:2022:08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,17 – 17,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 Pro-Bit 实验室 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z- 04507:2022:05 | PN-Z- 04507:2022:05/Ap1:2022:08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae4","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny) Stężenie pyłu – frakcja wdychalna"},{"name":"Zakres","range":"(0,18 – 17,90) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny) Stężenie pyłu – frakcja wdychalna\nZakres (0,18 – 17,90) mg/m3\nMetoda grawimetryczna","reference":"PN-Z- 04508:2022:05 | PN-Z- 04508:2022:05/Ap1:2022:08","norm_bases":["PN-Z- 04508:2022:05","PN-Z- 04508:2022:05/Ap1:2022:08"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny) Stężenie pyłu – frakcja wdychalna\nZakres (0,18 – 17,90) mg/m3\nMetoda grawimetryczna PN-Z- 04508:2022:05 | PN-Z- 04508:2022:05/Ap1:2022:08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny) Stezenie pylu – frakcja wdychalna\nZakres (0,18 – 17,90) mg/m3\nMetoda grawimetryczna PN-Z- 04508:2022:05 | PN-Z- 04508:2022:05/Ap1:2022:08","categories":["environment","construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown) Dust concentration – inhalable fraction"},{"name":"Range","range":"(0,18 – 17,90) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Pro-Bit Laboratory Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Dust concentration – inhalable fraction Range PN-Z- 04508:2022:05 | PN-Z- 04508:2022:05/Ap1:2022:08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"Węgiel (kamienny, brunatny) Stężenie pyłu – frakcja wdychalna"},{"name":"范围","range":"(0,18 – 17,90) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 Pro-Bit 实验室 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 范围 PN-Z- 04508:2022:05 | PN-Z- 04508:2022:05/Ap1:2022:08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分：","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae5","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo"},{"name":"przyspieszenie drgań"},{"name":"Zakres","range":"(0,07 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,07 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,07 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone\nZakres:\nczestotliwosciowo\nprzyspieszenie drgan\nZakres (0,07 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted"},{"name":"vibration acceleration"},{"name":"Range","range":"(0,07 – 50) m/s2"}],"search_en":"Workplace environment – whole-body vibration R.m.s. weighted Direct measurement method Pro-Bit Laboratory frequency-weighted vibration acceleration Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","parameters_zh":[{"name":"频率计权"},{"name":"振动加速度"},{"name":"范围","range":"(0,07 – 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 有效计权 直接测量法 Pro-Bit 实验室 频率计权 振动加速度 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"Pro-Bit 实验室","methodology_zh":"有效计权"},{"_id":"6a7d79870636ba417e41aae6","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) Pro-Bit Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） Pro-Bit 实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","lab_section_zh":"Pro-Bit 实验室"},{"_id":"6a7d79870636ba417e41aae7","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo"},{"name":"przyspieszenie drgań"},{"name":"Zakres","range":"(0,07 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015:11"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone\nZakres:\nczestotliwosciowo\nprzyspieszenie drgan\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted"},{"name":"vibration acceleration"},{"name":"Range","range":"(0,07 – 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration R.m.s. weighted Direct measurement method Pro-Bit Laboratory frequency-weighted vibration acceleration Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","parameters_zh":[{"name":"频率计权"},{"name":"振动加速度"},{"name":"范围","range":"(0,07 – 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 有效计权 直接测量法 Pro-Bit 实验室 频率计权 振动加速度 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"Pro-Bit 实验室","methodology_zh":"有效计权"},{"_id":"6a7d79870636ba417e41aae8","lab_id":"69ad52a3de79e566650fb708","country":"PL","accr_number":"AB 1371","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015:11"],"lab_section":"Laboratorium Pro-Bit","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Pro-Bit Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) Pro-Bit Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） Pro-Bit 实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015:11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","lab_section_zh":"Pro-Bit 实验室"}],"has_pdf":true}