{"lab":{"_id":"69ad52a3de79e566650fb702","accr_number":"AB 1364","country":"PL","accr_body":"PCA","address":"ul. Karola Olszewskiego 25, 32-566 Alwernia","categories":["water","environment","materials"],"city":"Alwernia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":45,"name":"„ALVENTA” S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1364.pdf"],"scope_summary":"","search_text":"„alventa” s.a. ul. karola olszewskiego 25, 32-566 alwernia environment materials other construction electronics pharma metrology water","status":"active","updated_at":"2026-03-08T14:50:32.329Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T08:54:22.611Z","email_confidence":"high","email_mx":true,"email_source":"https://alventa.com/kontakt/","parse_date":"2026-08-18T08:54:22.611Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling – working environment (harmful factors – air)"},{"codes":"C/28/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, lighting)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"N/28/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"}],"issue":{"no":"24","date":"11.08.2026"},"map_coord":[50.053714,19.524792],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM OCHRONY ŚRODOWISKA","address":"ul. Karola Olszewskiego 25, 32-566 Alwernia","city":"Alwernia","postal":"32-566"},{"name":"PRACOWNIA ICP","address":"ul. Karola Olszewskiego 25, 32-566 Alwernia","city":"Alwernia","postal":"32-566"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/18/6977433a0151f0931e7eedebe96512b5/AB%201364.pdf","has_en":true,"category_counts":{"water":25,"environment":20,"materials":4,"construction":2},"category_scores":{"water":12.25,"environment":7.84,"materials":0.31,"construction":0.08},"has_zh":true},"methods":[{"_id":"6a841dbeaf14b9c0e7b2144f","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna -substancje nieorganiczne, w tym"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna -substancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna -substancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna -substancje nieorganiczne, w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"frakcja respirabilna -substancje nieorganiczne, w tym"},{"name":"respirable fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"frakcja respirabilna -substancje nieorganiczne, w tym"},{"name":"呼吸性组分"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a841dbeaf14b9c0e7b21450","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method inorganic substances PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 无机物质 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"无机物质"}],"technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a841dbeaf14b9c0e7b21451","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a841dbeaf14b9c0e7b21452","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Cement portlandzki"},{"name":"Kaolin"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,17- 22,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nCement portlandzki\nKaolin\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17- 22,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nCement portlandzki\nKaolin\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17- 22,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nCement portlandzki\nKaolin\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,17- 22,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Portland cement"},{"name":"Kaolin"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,17- 22,0) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Portland cement Kaolin Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"高岭土"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,17- 22,0) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 硅酸盐水泥 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a841dbeaf14b9c0e7b21453","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Cement portlandzki"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,12-16,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nCement portlandzki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,12-16,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nCement portlandzki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,12-16,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nCement portlandzki\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,12-16,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Portland cement"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,12-16,0) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents - respirable fraction: Gravimetric method Portland cement Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,12-16,0) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 硅酸盐水泥 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a841dbeaf14b9c0e7b21454","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie / zawartość dekatlenku tetrafosforu","parameters":[{"name":"Zakres","range":"(0,1– 4,0) mg/m3"},{"name":"Zakres","range":"(0,0009 – 0,021) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,1– 4,0) mg/m3\nZakres (0,0009 – 0,021) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie / zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,1– 4,0) mg/m3\nZakres (0,0009 – 0,021) mg w próbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy − powietrze Stezenie / zawartosc dekatlenku tetrafosforu\nZakres:\nZakres (0,1– 4,0) mg/m3\nZakres (0,0009 – 0,021) mg w probce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of tetraphosphorus decaoxide","parameters_en":[{"name":"Range","range":"(0,1– 4,0) mg/m3"},{"name":"Range","range":"(0,0009 – 0,021) mg w próbce"}],"search_en":"Workplace environment − air Concentration / content of tetraphosphorus decaoxide Spectrophotometric method Range Range PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,1– 4,0) mg/m3"},{"name":"范围","range":"(0,0009 – 0,021) mg w próbce"}],"search_zh":"工作环境 − 空气 分光光度法 范围 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气"},{"_id":"6a841dbeaf14b9c0e7b21455","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,0005 – 0,05) mg/m3"},{"name":"Zakres","range":"(0,0002 – 0,02) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,0005 – 0,05) mg/m3\nZakres (0,0002 – 0,02) mg w próbce\nMetoda spektrofotometryczna","reference":"Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","norm_bases":["Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość związków chromu (VI) – w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,0005 – 0,05) mg/m3\nZakres (0,0002 – 0,02) mg w próbce\nMetoda spektrofotometryczna Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r. Srodowisko pracy − powietrze Stezenie/zawartosc zwiazkow chromu (VI) – w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,0005 – 0,05) mg/m3\nZakres (0,0002 – 0,02) mg w probce\nMetoda spektrofotometryczna Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chromium (VI) compounds – calculated as Cr (VI)","parameters_en":[{"name":"Range","range":"(0,0005 – 0,05) mg/m3"},{"name":"Range","range":"(0,0002 – 0,02) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of chromium (VI) compounds – calculated as Cr (VI) Spectrophotometric method Range Range Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,05) mg/m3"},{"name":"范围","range":"(0,0002 – 0,02) mg w próbce"}],"search_zh":"工作环境 − 空气 铬(VI)化合物的浓度/含量 － 以 Cr(VI) 计 分光光度法 范围 范围 Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"铬(VI)化合物的浓度/含量 － 以 Cr(VI) 计"},{"_id":"6a841dbeaf14b9c0e7b21456","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,009 – 0,500) mg/m3"},{"name":"Zakres","range":"(10 – 400) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,500) mg/m3\nZakres (10 – 400) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","reference":"Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","norm_bases":["Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,500) mg/m3\nZakres (10 – 400) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR) Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r. Srodowisko pracy − powietrze Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,500) mg/m3\nZakres (10 – 400) μg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT- IR) Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(0,009 – 0,500) mg/m3"},{"name":"Range","range":"(10 – 400) μg w próbce"}],"search_en":"Workplace environment − air Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction Fourier transform infrared spectrometry (FT- IR) Range Range Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","technique_en":"Fourier transform infrared spectrometry (FT- IR)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,009 – 0,500) mg/m3"},{"name":"范围","range":"(10 – 400) μg w próbce"}],"search_zh":"工作环境 − 空气 傅里叶变换红外光谱法（FT-IR） 范围 范围 Metodyka NIOSH nr 7600 wydanie 3:20.10.2015 r.","test_object_zh":"工作环境 − 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a841dbeaf14b9c0e7b21457","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 122) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 122) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 122) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 – 122) dB\nSzczytowy poziom dzwieku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 pkt. 10 i strategie 3 pkt. 11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25 – 122) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35 – 138) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 – 122) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 – 138) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a841dbeaf14b9c0e7b21458","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy (z obliczeń)"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń)\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń)\nprzeciętnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy (z obliczen)\nprzecietnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 pkt. 10 i strategie 3 pkt. 11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time (calculated)"},{"name":"average weekly working time"}],"search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time (calculated) average weekly working time PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","test_object_en":"Workplace environment − noise","methodology_zh":"噪声暴露级，参照：","search_zh":"工作环境 − 噪声 噪声暴露级，参照： 每日 8 小时工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 pkt. 10 i strategię 3 pkt. 11","test_object_zh":"工作环境 − 噪声","parameters_zh":[{"name":"每日 8 小时工作时间（由计算得出）"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}]},{"_id":"6a841dbeaf14b9c0e7b21459","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","norm_bases":["PB/LO/13 wydanie 6 z dnia 14.04.2022 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PB/LO/13 wydanie 6 z dnia 14.04.2022 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a841dbeaf14b9c0e7b2145a","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","norm_bases":["PB/LO/13 wydanie 6 z dnia 14.04.2022 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PB/LO/13 wydanie 6 z dnia 14.04.2022 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PB/LO/13 wydanie 6 z dnia 14.04.2022 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a841dbeaf14b9c0e7b2145b","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i właściwości fizycznych","parameters":[{"name":"Temperatura ścieków/ pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i właściwości fizycznych\nZakres:\nTemperatura ścieków/ pobranej próbki ścieków\nZakres (0,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i właściwości fizycznych\nZakres:\nTemperatura ścieków/ pobranej próbki ścieków\nZakres (0,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i wlasciwosci fizycznych\nZakres:\nTemperatura sciekow/ pobranej probki sciekow\nZakres (0,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical testing and physical properties","parameters_en":[{"name":"Temperature of wastewater/ collected wastewater sample"},{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Wastewater Sampling for chemical testing and physical properties Manual method; Automatic method Temperature of wastewater/ collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学检测与物理性能检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"污水 化学检测与物理性能检测用样品采集 手动法；自动法 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a841dbeaf14b9c0e7b2145c","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0-50) oC"},{"name":"Pomiar poziomu zwierciadła wody"},{"name":"Zakres","range":"(0-50) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres:\nZakres (0-50) oC\nPomiar poziomu zwierciadła wody\nZakres (0-50) m","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2,6.3 | PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2,6.3","PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres:\nZakres (0-50) oC\nPomiar poziomu zwierciadła wody\nZakres (0-50) m PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2,6.3 | PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres:\nZakres (0-50) oC\nPomiar poziomu zwierciadla wody\nZakres (0-50) m PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2, 6.1.2, 6.2,6.3 | PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0-50) oC"},{"name":"Measurement of the water table level"},{"name":"Range","range":"(0-50) m"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range Measurement of the water table level Range PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2,6.3 | PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0-50) oC"},{"name":"Pomiar poziomu zwierciadła wody"},{"name":"范围","range":"(0-50) m"}],"search_zh":"地下水 化学和物理检测采样 所采水样的温度 范围 范围 PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2,6.3 | PN-77/C-04584 PB/LO/32 wyd.4 02.03.2020","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地下水"},{"_id":"6a841dbeaf14b9c0e7b2145d","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"zakres","range":"(4,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nzakres (4,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nzakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nzakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"range","range":"(4,0 – 12,0)"}],"search_en":"Water, wastewater pH Potentiometric method range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","parameters_zh":[{"name":"范围","range":"(4,0 – 12,0)"}]},{"_id":"6a841dbeaf14b9c0e7b2145e","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 50000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 50000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (100 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 50000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 50000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b2145f","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21460","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem 7.2.1, 7.2.2 | ISO 17289:2014","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem 7.2.1, 7.2.2","ISO 17289:2014"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem 7.2.1, 7.2.2 | ISO 17289:2014 Woda, scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem 7.2.1, 7.2.2 | ISO 17289:2014","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand BOD5 Optical method Range PN-EN 1899-2:2002 z wyłączeniem 7.2.1, 7.2.2 | ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 BZT5（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wyłączeniem 7.2.1, 7.2.2 | ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21461","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(3 – 300) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 300) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 300) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 300) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand BOD5","parameters_en":[{"name":"Range","range":"(3 – 300) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(3 – 300) mg/l O2"}],"search_zh":"水、废水 生化需氧量 BZT5（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21462","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,150 – 360) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,150 – 360) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 z wyłączeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 z wyłączeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,150 – 360) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 z wyłączeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,150 – 360) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 z wylaczeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,150 – 360) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 z wyłączeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,150 – 360) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 z wyłączeniem pkt. 5 i 6 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a841dbeaf14b9c0e7b21463","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 z wyłączeniem pkt 8 + Ap1:2010 + Ap 2:2010","norm_bases":["PN-EN ISO 6878:2006 z wyłączeniem pkt 8 + Ap1:2010 + Ap 2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 z wyłączeniem pkt 8 + Ap1:2010 + Ap 2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 z wylaczeniem pkt 8 + Ap1:2010 + Ap 2:2010","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 40,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 z wyłączeniem pkt 8 + Ap1:2010 + Ap 2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 40,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 z wyłączeniem pkt 8 + Ap1:2010 + Ap 2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21464","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (5,00 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (5,00 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (5,00 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a841dbeaf14b9c0e7b21465","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21466","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 8000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 8000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,00 – 8000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,00 – 8000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 8000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 8000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21467","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 40,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 40,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21468","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a841dbeaf14b9c0e7b21469","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b2146a","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration (calculated)","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN 26777:1999","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a841dbeaf14b9c0e7b2146b","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50,0) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50,0) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b2146c","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów (z obliczeń) PN-82/C-04576/08 Woda, scieki Stezenie azotanow (z obliczen) PN-82/C-04576/08","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration (calculated)","search_en":"Water, wastewater Nitrate concentration (calculated) PN-82/C-04576/08","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐浓度（由计算得出） PN-82/C-04576/08","test_object_zh":"水、废水","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a841dbeaf14b9c0e7b2146d","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 40,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 40,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 40,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b2146e","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","norm_bases":["PB/LO/29 wydanie 4 z dnia 1.07.2020 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu organicznego (z obliczeń) PB/LO/29 wydanie 4 z dnia 1.07.2020 r. Woda, scieki Stezenie azotu organicznego (z obliczen) PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic nitrogen concentration (calculated)","search_en":"Water, wastewater Organic nitrogen concentration (calculated) PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","test_object_en":"Water, wastewater","search_zh":"水、废水 有机氮浓度（由计算得出） PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","test_object_zh":"水、废水","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a841dbeaf14b9c0e7b2146f","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","norm_bases":["PB/LO/29 wydanie 4 z dnia 1.07.2020 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB/LO/29 wydanie 4 z dnia 1.07.2020 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB/LO/29 wydanie 4 z dnia 1.07.2020 r.","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21470","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testów Hach LCK138, LCK 238, LCK 338","norm_bases":["PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testów Hach LCK138, LCK 238, LCK 338"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testów Hach LCK138, LCK 238, LCK 338 Woda, scieki Stezenie azotu ogolnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testow Hach LCK138, LCK 238, LCK 338","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100,0) mg/l"}],"search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testów Hach LCK138, LCK 238, LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100,0) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 PB/LO/23 wydanie 3 z dnia 1.07.2020 r. na podstawie testów Hach LCK138, LCK 238, LCK 338","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a841dbeaf14b9c0e7b21471","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,020 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604.08","norm_bases":["PN-77/C-04604.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08 Woda, scieki Stezenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,020 – 5,0) mg/l"}],"search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604.08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,020 – 5,0) mg/l"}],"search_zh":"水、废水 六价铬浓度 分光光度法 范围 PN-77/C-04604.08","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a841dbeaf14b9c0e7b21472","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,020 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (0,020 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,020 – 5,0) mg/l"}],"search_en":"Water Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,020 – 5,0) mg/l"}],"search_zh":"水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a841dbeaf14b9c0e7b21473","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu; chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr (0,00014 – 1,39) mg/m3 (0,00010– 1,00) mg w próbce","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu; chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr (0,00014 – 1,39) mg/m3 (0,00010– 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość chromu metalicznego, związków chromu; chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr (0,00014 – 1,39) mg/m3 (0,00010– 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc chromu metalicznego, zwiazkow chromu; chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr (0,00014 – 1,39) mg/m3 (0,00010– 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["materials","environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21474","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość chromu metalicznego związki chromu (II) – w przeliczeniu na Cr (II) związki chromu (III) – w przeliczeniu na Cr (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego związki chromu (II) – w przeliczeniu na Cr (II) związki chromu (III) – w przeliczeniu na Cr (III) (z obliczeń)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość chromu metalicznego związki chromu (II) – w przeliczeniu na Cr (II) związki chromu (III) – w przeliczeniu na Cr (III) (z obliczeń) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc chromu metalicznego zwiazki chromu (II) – w przeliczeniu na Cr (II) zwiazki chromu (III) – w przeliczeniu na Cr (III) (z obliczen) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["materials","environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of metallic chromium chromium (II) compounds – calculated as Cr (II) chromium (III) compounds – calculated as Cr (III) (calculated)","search_en":"Workplace environment – air Concentration/content of metallic chromium chromium (II) compounds – calculated as Cr (II) chromium (III) compounds – calculated as Cr (III) (calculated) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21475","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu (0,00028 – 1,39) mg/m3 (0,00020 – 1,00) mg w próbce","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu (0,00028 – 1,39) mg/m3 (0,00020 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu (0,00028 – 1,39) mg/m3 (0,00020 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc miedzi i jej zwiazkow nieorganicznych – w przeliczeniu na Cu (0,00028 – 1,39) mg/m3 (0,00020 – 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21476","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość niklu i jego związków w przeliczeniu na Ni","parameters":[{"name":"frakcja wdychalna:","range":"(0,00014 – 1,39) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"},{"name":"frakcja respirabilna:","range":"(0,00015 – 1,46) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość niklu i jego związków w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna: (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w próbce\nfrakcja respirabilna: (0,00015 – 1,46) mg/m3\n(0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość niklu i jego związków w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna: (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w próbce\nfrakcja respirabilna: (0,00015 – 1,46) mg/m3\n(0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc niklu i jego zwiazkow w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna: (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w probce\nfrakcja respirabilna: (0,00015 – 1,46) mg/m3\n(0,00010 – 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction:","range":"(0,00014 – 1,39) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"},{"name":"frakcja respirabilna:","range":"(0,00015 – 1,46) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"}],"search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction: PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21477","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna","range":"(0,00014 – 1,39) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc olowiu i jego zwiazkow nieorganicznych w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna (0,00014 – 1,39) mg/m3\n(0,00010 – 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction","range":"(0,00014 – 1,39) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"}],"search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分","range":"(0,00014 – 1,39) mg/m3"},{"name":"(0,00010 – 1,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21478","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/ zawartość manganu i jego związków nieorganicznych, w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00014 – 1,39) mg/m3"},{"name":"Zakres","range":"(0,00010 – 1,00) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,00015 – 1,46) mg/m3"},{"name":"Zakres","range":"(0,00010 – 1,00) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/ zawartość manganu i jego związków nieorganicznych, w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,00014 – 1,39) mg/m3\nZakres (0,00010 – 1,00) mg w próbce\nfrakcja respirabilna\nZakres (0,00015 – 1,46) mg/m3\nZakres (0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/ zawartość manganu i jego związków nieorganicznych, w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,00014 – 1,39) mg/m3\nZakres (0,00010 – 1,00) mg w próbce\nfrakcja respirabilna\nZakres (0,00015 – 1,46) mg/m3\nZakres (0,00010 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/ zawartosc manganu i jego zwiazkow nieorganicznych, w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,00014 – 1,39) mg/m3\nZakres (0,00010 – 1,00) mg w probce\nfrakcja respirabilna\nZakres (0,00015 – 1,46) mg/m3\nZakres (0,00010 – 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,00014 – 1,39) mg/m3"},{"name":"Range","range":"(0,00010 – 1,00) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,00015 – 1,46) mg/m3"},{"name":"Range","range":"(0,00010 – 1,00) mg w próbce"}],"search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Range respirable fraction Range Range PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00014 – 1,39) mg/m3"},{"name":"范围","range":"(0,00010 – 1,00) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,00015 – 1,46) mg/m3"},{"name":"范围","range":"(0,00010 – 1,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b21479","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość kadmu i jego związków nieorganicznych, w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00028 – 1,39) mg/m3"},{"name":"Zakres","range":"(0,00020 – 1,00) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość kadmu i jego związków nieorganicznych, w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00028 – 1,39) mg/m3\nZakres (0,00020 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość kadmu i jego związków nieorganicznych, w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00028 – 1,39) mg/m3\nZakres (0,00020 – 1,00) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc kadmu i jego zwiazkow nieorganicznych, w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00028 – 1,39) mg/m3\nZakres (0,00020 – 1,00) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,00028 – 1,39) mg/m3"},{"name":"Range","range":"(0,00020 – 1,00) mg w próbce"}],"search_en":"Workplace environment – air Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Range PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00028 – 1,39) mg/m3"},{"name":"范围","range":"(0,00020 – 1,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 范围 PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b2147a","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014 – 20,83) mg/m3"},{"name":"Zakres","range":"(0,0010 – 15,0) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0015 – 21,93) mg/m3"},{"name":"Zakres","range":"(0,0010 – 15,0) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 20,83) mg/m3\nZakres (0,0010 – 15,0) mg w próbce\nfrakcja respirabilna\nZakres (0,0015 – 21,93) mg/m3\nZakres (0,0010 – 15,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","norm_bases":["PB/LO/09 wydanie 9 z dnia 14.04.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 20,83) mg/m3\nZakres (0,0010 – 15,0) mg w próbce\nfrakcja respirabilna\nZakres (0,0015 – 21,93) mg/m3\nZakres (0,0010 – 15,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r. Srodowisko pracy – powietrze Stezenie/zawartosc tlenkow zelaza – w przeliczeniu na Fe Tlenek zelaza (III) Tlenek zelaza (II) Tetratlenek trizelaza\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 20,83) mg/m3\nZakres (0,0010 – 15,0) mg w probce\nfrakcja respirabilna\nZakres (0,0015 – 21,93) mg/m3\nZakres (0,0010 – 15,0) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of iron oxides – calculated as Fe Iron(III) oxide Iron(II) oxide Triiron tetraoxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014 – 20,83) mg/m3"},{"name":"Range","range":"(0,0010 – 15,0) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0015 – 21,93) mg/m3"},{"name":"Range","range":"(0,0010 – 15,0) mg w próbce"}],"search_en":"Workplace environment – air Concentration/content of iron oxides – calculated as Fe Iron(III) oxide Iron(II) oxide Triiron tetraoxide Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Range respirable fraction Range Range PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0014 – 20,83) mg/m3"},{"name":"范围","range":"(0,0010 – 15,0) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0015 – 21,93) mg/m3"},{"name":"范围","range":"(0,0010 – 15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB/LO/09 wydanie 9 z dnia 14.04.2025 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a841dbeaf14b9c0e7b2147b","lab_id":"69ad52a3de79e566650fb702","country":"PL","accr_number":"AB 1364","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Cr, Pb, Zn, Ni, Mn","range":"(0,010 – 5,0) mg/l"},{"name":"As","range":"(0,020 – 1,0) mg/l"},{"name":"Cu, Cd, Ag","range":"(0,020 – 5,0) mg/l"},{"name":"Fe","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nCr, Pb, Zn, Ni, Mn (0,010 – 5,0) mg/l\nAs (0,020 – 1,0) mg/l\nCu, Cd, Ag (0,020 – 5,0) mg/l\nFe (0,10 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nCr, Pb, Zn, Ni, Mn (0,010 – 5,0) mg/l\nAs (0,020 – 1,0) mg/l\nCu, Cd, Ag (0,020 – 5,0) mg/l\nFe (0,10 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali:\nZakres:\nCr, Pb, Zn, Ni, Mn (0,010 – 5,0) mg/l\nAs (0,020 – 1,0) mg/l\nCu, Cd, Ag (0,020 – 5,0) mg/l\nFe (0,10 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Cr, Pb, Zn, Ni, Mn","range":"(0,010 – 5,0) mg/l"},{"name":"As","range":"(0,020 – 1,0) mg/l"},{"name":"Cu, Cd, Ag","range":"(0,020 – 5,0) mg/l"},{"name":"Fe","range":"(0,10 – 20,0) mg/l"}],"search_en":"Water, wastewater Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) As Fe PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","search_zh":"水、废水 金属浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） As Fe PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","parameters_zh":[{"name":"Cr, Pb, Zn, Ni, Mn","range":"(0,010 – 5,0) mg/l"},{"name":"As","range":"(0,020 – 1,0) mg/l"},{"name":"Cu, Cd, Ag","range":"(0,020 – 5,0) mg/l"},{"name":"Fe","range":"(0,10 – 20,0) mg/l"}],"methodology_zh":"金属浓度："}],"has_pdf":true}