{"lab":{"_id":"69ad52a3de79e566650fb6fa","accr_number":"AB 1360","country":"PL","accr_body":"PCA","address":"ul. Czempińska 2, 64-000 Kościan, LABORATORIUM „WODOCIĄGÓW KOŚCIAŃSKICH” Sp. z o.o., ul. Kanałowa 1, 64-000 Kościan","categories":["water"],"city":"Kościan","imported_at":"2026-03-08T10:42:43.265Z","methods_count":45,"name":"„WODOCIĄGI KOŚCIAŃSKIE” Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1360.pdf"],"scope_summary":"","search_text":"„wodociągi kościańskie” sp. z o.o. ul. czempińska 2, 64-000 kościan, laboratorium „wodociągów kościańskich” sp. z o.o., ul. kanałowa 1, 64-000 kościan water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:32.092Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:00:06.497Z","email_confidence":"high","email_mx":true,"email_source":"https://www.wodociagi-koscian.pl/index.php/dla-klientow/adresy-i-telefony.html","parse_date":"2026-08-13T08:00:06.497Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"17","date":"26.06.2026"},"map_coord":[52.094913,16.658876],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM „WODOCIĄGÓW KOŚCIAŃSKICH” Sp. z o.o.","address":"ul. Kanałowa 1","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/a21db5d52521846b1b9f7eb82a289492/AB%201360.pdf","has_en":true,"category_counts":{"water":45},"category_scores":{"water":45},"has_zh":true},"methods":[{"_id":"6a7d79860636ba417e41aaa6","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 15) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 15) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 15) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaa7","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaa8","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(90 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (90 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (90 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (90 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(90 – 2500) μS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(90 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaa9","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda, woda do spozycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 60) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 60) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaaa","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,02 – 0,70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,02 – 0,70) mg/l\nMetoda spektrofotometryczna","reference":"PB-02/W z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 91860","norm_bases":["PB-02/W z dn. 25.04.2022 wydanie 9","na podstawie testu kuwetowego Nanocolor nr 91860"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,02 – 0,70) mg/l\nMetoda spektrofotometryczna PB-02/W z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 91860 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,02 – 0,70) mg/l\nMetoda spektrofotometryczna PB-02/W z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 91860","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,02 – 0,70) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PB-02/W z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 91860","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 0,70) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PB-02/W z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 91860","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaab","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaac","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 500) mg/l"}],"search_en":"Water, water intended for human consumption Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 500) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaad","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,033 – 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,033 – 15) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,033 – 15) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,033 – 15) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,033 – 15) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,033 – 15) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaae","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,20 – 150) mg/l"}],"search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 150) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aaaf","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","norm_bases":["PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna PB-01/W,S z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,04 – 15,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 15,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aab0","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(25 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (25 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"P N -ISO 6059:1999","norm_bases":["P N -ISO 6059:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (25 – 1000) mg/l CaCO3\nMetoda miareczkowa P N -ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (25 – 1000) mg/l CaCO3\nMetoda miareczkowa P N -ISO 6059:1999","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(25 – 1000) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range P N -ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(25 – 1000) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 P N -ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aab1","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aab2","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(3,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (3,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (3,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (3,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(3,0 – 250) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(3,0 – 250) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a7d79860636ba417e41aab3","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999, Załącznik A","norm_bases":["PN-C-04554-4:1999, Załącznik A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999, Załącznik A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999, Zalacznik A","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999, Załącznik A","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999, Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a7d79860636ba417e41aab4","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonów amonowych","parameters":[{"name":"Zakres","range":"(0,13 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonów amonowych\nZakres (0,13 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonów amonowych\nZakres (0,13 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonow amonowych\nZakres (0,13 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,13 – 10,0) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,13 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a7d79860636ba417e41aab5","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06 z wył. pkt.7.1.2","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06 z wył. pkt.7.1.2"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 z wył. pkt.7.1.2 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 z wyl. pkt.7.1.2","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 – 20,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06 z wył. pkt.7.1.2","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 20,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06 z wył. pkt.7.1.2","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79860636ba417e41aab6","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d79860636ba417e41aab7","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda na pływalniach","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 – 2,2) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna","reference":"PB-05/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8021 DPD Hach Lange","norm_bases":["PB-05/W z dn. 25.04.2022 wydanie 3","na podstawie testu 8021 DPD Hach Lange"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda na pływalniach Stężenie chloru wolnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna PB-05/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8021 DPD Hach Lange Woda do spozycia przez ludzi, woda na plywalniach Stezenie chloru wolnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna PB-05/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8021 DPD Hach Lange","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,2) mg/l"}],"search_en":"Water intended for human consumption, swimming pool water Free chlorine concentration Colorimetric method Range PB-05/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8021 DPD Hach Lange","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption, swimming pool water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,2) mg/l"}],"search_zh":"生活饮用水、游泳池水 游离氯浓度 比色法 范围 PB-05/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8021 DPD Hach Lange","technique_zh":"比色法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7d79860636ba417e41aab8","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C","reference":"PB-13/W z dn. 26.04.2023 wydanie 5 | PN-77/C-04584","norm_bases":["PB-13/W z dn. 26.04.2023 wydanie 5","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C PB-13/W z dn. 26.04.2023 wydanie 5 | PN-77/C-04584 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (2,0 – 50,0) °C PB-13/W z dn. 26.04.2023 wydanie 5 | PN-77/C-04584","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Swimming pool water Sampling for chemical and physical testing Temperature Range PB-13/W z dn. 26.04.2023 wydanie 5 | PN-77/C-04584","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"游泳池水 化学和物理检测采样 温度 范围 PB-13/W z dn. 26.04.2023 wydanie 5 | PN-77/C-04584","test_object_zh":"游泳池水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d79860636ba417e41aab9","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a7d79860636ba417e41aaba","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(220 – 800) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 800) mV\nMetoda potencjometryczna","reference":"PB-12/W z dn. 25.04.2022 wydanie 3","norm_bases":["PB-12/W z dn. 25.04.2022 wydanie 3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 800) mV\nMetoda potencjometryczna PB-12/W z dn. 25.04.2022 wydanie 3 Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 800) mV\nMetoda potencjometryczna PB-12/W z dn. 25.04.2022 wydanie 3","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(220 – 800) mV"}],"search_en":"Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-12/W z dn. 25.04.2022 wydanie 3","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(220 – 800) mV"}],"search_zh":"游泳池水 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 PB-12/W z dn. 25.04.2022 wydanie 3","technique_zh":"电位法","test_object_zh":"游泳池水","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a7d79860636ba417e41aabb","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 2,2) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna","reference":"PB-09/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8167 DPD Hach Lange","norm_bases":["PB-09/W z dn. 25.04.2022 wydanie 3","na podstawie testu 8167 DPD Hach Lange"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru ogólnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna PB-09/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8167 DPD Hach Lange Woda na plywalniach Stezenie chloru ogolnego\nZakres (0,10 – 2,2) mg/l\nMetoda kolorymetryczna PB-09/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8167 DPD Hach Lange","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,2) mg/l"}],"search_en":"Swimming pool water Total chlorine concentration Colorimetric method Range PB-09/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8167 DPD Hach Lange","technique_en":"Colorimetric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,10 – 2,2) mg/l"}],"search_zh":"游泳池水 总氯浓度 比色法 范围 PB-09/W z dn. 25.04.2022 wydanie 3 | na podstawie testu 8167 DPD Hach Lange","technique_zh":"比色法","test_object_zh":"游泳池水","methodology_zh":"总氯浓度"},{"_id":"6a7d79860636ba417e41aabc","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-04/W z dn. 01.03.2019 wydanie 3","norm_bases":["PB-04/W z dn. 01.03.2019 wydanie 3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) PB-04/W z dn. 01.03.2019 wydanie 3 Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) PB-04/W z dn. 01.03.2019 wydanie 3","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Swimming pool water Combined chlorine concentration (calculated) PB-04/W z dn. 01.03.2019 wydanie 3","test_object_en":"Swimming pool water","search_zh":"游泳池水 化合氯浓度（计算值） PB-04/W z dn. 01.03.2019 wydanie 3","test_object_zh":"游泳池水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a7d79860636ba417e41aabd","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 15) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Mętność\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,30 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 15) NTU"}],"search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Swimming pool water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 15) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a7d79860636ba417e41aabe","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Swimming pool water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a7d79860636ba417e41aabf","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda na plywalniach Stezenie azotanow\nZakres (0,20 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,20 – 150) mg/l"}],"search_en":"Swimming pool water Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 150) mg/l"}],"search_zh":"游泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a7d79860636ba417e41aac0","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac1","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac2","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Titrimetric method Range PN-EN ISO 5815-1:2019-12","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 滴定法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d79860636ba417e41aac3","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(15 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(15 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(15 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac4","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,2 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,2 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-07/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079","norm_bases":["PB-07/Ś z dn. 25.04.2022 wydanie 9","na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,2 – 50) mg/l\nMetoda spektrofotometryczna PB-07/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079 Scieki Stezenie fosforu ogolnego\nZakres (0,2 – 50) mg/l\nMetoda spektrofotometryczna PB-07/S z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,2 – 50) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB-07/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 50) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB-07/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985076, 985080, 985079","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac5","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(3,0 – 220) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (3,0 – 220) mg/l\nMetoda spektrofotometryczna","reference":"PB-08/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985088","norm_bases":["PB-08/Ś z dn. 25.04.2022 wydanie 9","na podstawie testu kuwetowego Nanocolor nr 985088"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (3,0 – 220) mg/l\nMetoda spektrofotometryczna PB-08/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985088 Scieki Stezenie azotu ogolnego\nZakres (3,0 – 220) mg/l\nMetoda spektrofotometryczna PB-08/S z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985088","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,0 – 220) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-08/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985088","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 – 220) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-08/Ś z dn. 25.04.2022 wydanie 9 | na podstawie testu kuwetowego Nanocolor nr 985088","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac6","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 700) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 700) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 700) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 700) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 700) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 700) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac7","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac8","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aac9","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,05 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 50) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aaca","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (3,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (3,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,0 – 1000) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 – 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aacb","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-10/Ś z dn. 01.03.2019 wydanie 4","norm_bases":["PB-10/Ś z dn. 01.03.2019 wydanie 4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB-10/Ś z dn. 01.03.2019 wydanie 4 Scieki Stezenie azotu ogolnego (z obliczen) PB-10/S z dn. 01.03.2019 wydanie 4","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) PB-10/Ś z dn. 01.03.2019 wydanie 4","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB-10/Ś z dn. 01.03.2019 wydanie 4","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aacc","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","norm_bases":["PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836 Scieki Stezenie zelaza ogolnego\nZakres (0,04 – 15,0) mg/l\nMetoda spektrofotometryczna PB-01/W,S z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,04 – 15,0) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 15,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PB-01/W,Ś z dn. 25.04.2022 wydanie 10 na podstawie testu kuwetowego Nanocolor nr 91836","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aacd","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(30 – 800) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (30 – 800) mg/l\nMetoda turbidymetryczna","reference":"PB-11/Ś z dn. 28.09.2022 wydanie 4 | na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063","norm_bases":["PB-11/Ś z dn. 28.09.2022 wydanie 4","na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (30 – 800) mg/l\nMetoda turbidymetryczna PB-11/Ś z dn. 28.09.2022 wydanie 4 | na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063 Scieki Stezenie siarczanow\nZakres (30 – 800) mg/l\nMetoda turbidymetryczna PB-11/S z dn. 28.09.2022 wydanie 4 | na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(30 – 800) mg/l"}],"search_en":"Wastewater Sulfate concentration Turbidimetric method Range PB-11/Ś z dn. 28.09.2022 wydanie 4 | na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063","technique_en":"Turbidimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(30 – 800) mg/l"}],"search_zh":"污水 硫酸盐浓度 浊度法 范围 PB-11/Ś z dn. 28.09.2022 wydanie 4 | na podstawie testu kuwetowego Nanocolor nr 985 062, 985 063","test_object_zh":"污水","technique_zh":"浊度法"},{"_id":"6a7d79860636ba417e41aace","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 80) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 80) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79860636ba417e41aacf","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PB-14/Ś z dn. 25.04.2022 wydanie 4","norm_bases":["PB-14/Ś z dn. 25.04.2022 wydanie 4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-14/Ś z dn. 25.04.2022 wydanie 4 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-14/S z dn. 25.04.2022 wydanie 4","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-14/Ś z dn. 25.04.2022 wydanie 4","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 PB-14/Ś z dn. 25.04.2022 wydanie 4","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7d79860636ba417e41aad0","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d79860636ba417e41aad1","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a7d79860636ba417e41aad2","lab_id":"69ad52a3de79e566650fb6fa","country":"PL","accr_number":"AB 1360","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 700) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 700) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 700) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 700) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 700) mg/l"}],"search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 700) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水"}],"has_pdf":true}