{"lab":{"_id":"69ad52a3de79e566650fb6f8","accr_number":"AB 1359","country":"PL","accr_body":"PCA","address":"ul. Chopina 96, 43-600 Jaworzno","categories":["construction"],"city":"Jaworzno","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"ASPEKT Laboratorium Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1359.pdf"],"scope_summary":"","search_text":"aspekt laboratorium sp. z o.o. ul. chopina 96, 43-600 jaworzno construction metrology food other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:32.026Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:59:58.576Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201359,podmiot.html","parse_date":"2026-08-13T07:59:58.576Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"A/5","pl":"­ Badania drgań obiektów budowlanych","en":"Vibration tests of building items"},{"codes":"J/5","pl":"­ Badania mechaniczne obiektów budowlanych","en":"Mechanical tests of building items"}],"issue":{"no":"16","date":"28.07.2026"},"map_coord":[50.188438,19.256571],"map_geo":"nominatim-street","lab_locations":[{"name":"Aspekt Laboratorium Sp. z o.o.","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/78d60235acc1a1bbd79e14db7231ad0b/AB%201359.pdf","has_en":true,"category_counts":{"construction":9},"category_scores":{"construction":9},"has_zh":true,"lab_locations_zh":[{"name":"Aspekt Laboratorium 有限责任公司","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d797e0636ba417e41aa4a","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"± 100 mm"},{"name":"Pomiar z zastosowaniem czujników przemieszczeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujników przemieszczeń","reference":"PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","norm_bases":["PN-S-10040:1999","PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujników przemieszczeń PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu statycznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujnikow przemieszczen PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of vertical displacements under static load","parameters_en":[{"name":"Range","range":"± 100 mm"},{"name":"Measurement using displacement sensors"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under static load Aspekt Laboratorium Sp. z o.o. Range Measurement using displacement sensors PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 100 mm"},{"name":"采用位移传感器的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静载荷下的竖向位移测量 Aspekt Laboratorium 有限责任公司 范围 采用位移传感器的测定 PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"静载荷下的竖向位移测量"},{"_id":"6a7d797e0636ba417e41aa4b","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"± 250 mm"},{"name":"Lokalizacja punktu odniesienia:","range":"do 100 m"},{"name":"Pomiar z zastosowaniem niwelacji precyzyjnej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres ± 250 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej","reference":"PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","norm_bases":["PN-S-10040:1999","PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres ± 250 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu statycznym\nZakres:\nZakres ± 250 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of vertical displacements under static load","parameters_en":[{"name":"Range","range":"± 250 mm"},{"name":"Location of the reference point:","range":"do 100 m"},{"name":"Measurement using precise levelling"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under static load Aspekt Laboratorium Sp. z o.o. Range Location of the reference point: Measurement using precise levelling PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 250 mm"},{"name":"Lokalizacja punktu odniesienia:","range":"do 100 m"},{"name":"采用精密水准测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静载荷下的竖向位移测量 Aspekt Laboratorium 有限责任公司 范围 采用精密水准测量的测定 PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"静载荷下的竖向位移测量"},{"_id":"6a7d797e0636ba417e41aa4c","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar osiadania podpór przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"± 50 mm"},{"name":"Lokalizacja punktu odniesienia:","range":"do 100 m"},{"name":"Pomiar z zastosowaniem niwelacji precyzyjnej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar osiadania podpór przy obciążeniu statycznym\nZakres:\nZakres ± 50 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej","reference":"PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","norm_bases":["PN-S-10040:1999","PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar osiadania podpór przy obciążeniu statycznym\nZakres:\nZakres ± 50 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar osiadania podpor przy obciazeniu statycznym\nZakres:\nZakres ± 50 mm\nLokalizacja punktu odniesienia: do 100 m\nPomiar z zastosowaniem niwelacji precyzyjnej PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of support settlement under static load","parameters_en":[{"name":"Range","range":"± 50 mm"},{"name":"Location of the reference point:","range":"do 100 m"},{"name":"Measurement using precise levelling"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of support settlement under static load Aspekt Laboratorium Sp. z o.o. Range Location of the reference point: Measurement using precise levelling PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 50 mm"},{"name":"Lokalizacja punktu odniesienia:","range":"do 100 m"},{"name":"采用精密水准测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静荷载下支座沉降的测量 Aspekt Laboratorium 有限责任公司 范围 采用精密水准测量的测定 PN-S-10040:1999 | PN-89/S-10050 PB1 wyd.14 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"静荷载下支座沉降的测量"},{"_id":"6a7d797e0636ba417e41aa4d","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar odkształceń jednostkowych przy obciążeniu statycznym","parameters":[{"name":"Zakres","range":"± 2000 μm/m"},{"name":"Pomiar z zastosowaniem elektrycznej tensometrii oporowej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar odkształceń jednostkowych przy obciążeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej","reference":"PB5 wyd.6 z dnia 17.07.2026 r.","norm_bases":["PB5 wyd.6 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar odkształceń jednostkowych przy obciążeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar odksztalcen jednostkowych przy obciazeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r.","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of unit strains under static load","parameters_en":[{"name":"Range","range":"± 2000 μm/m"},{"name":"Measurement using electrical resistance strain gauges"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of unit strains under static load Aspekt Laboratorium Sp. z o.o. Range Measurement using electrical resistance strain gauges PB5 wyd.6 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 2000 μm/m"},{"name":"采用电阻应变测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静荷载下单位变形的测量 Aspekt Laboratorium 有限责任公司 范围 采用电阻应变测量的测定 PB5 wyd.6 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"静荷载下单位变形的测量"},{"_id":"6a7d797e0636ba417e41aa4e","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym","parameters":[{"name":"Zakres","range":"± 100 mm"},{"name":"Pomiar z zastosowaniem czujników przemieszczeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujników przemieszczeń","reference":"PN-S-10040:1999 | PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r.","norm_bases":["PN-S-10040:1999","PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujników przemieszczeń PN-S-10040:1999 | PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu dynamicznym\nZakres:\nZakres ± 100 mm\nPomiar z zastosowaniem czujnikow przemieszczen PN-S-10040:1999 | PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r.","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of vertical displacements under dynamic loading","parameters_en":[{"name":"Range","range":"± 100 mm"},{"name":"Measurement using displacement sensors"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under dynamic loading Aspekt Laboratorium Sp. z o.o. Range Measurement using displacement sensors PN-S-10040:1999 | PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 100 mm"},{"name":"采用位移传感器的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下的竖向位移测量 Aspekt Laboratorium 有限责任公司 范围 采用位移传感器的测定 PN-S-10040:1999 | PN-89/S-10050 PB2 wyd.12 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"动荷载下的竖向位移测量"},{"_id":"6a7d797e0636ba417e41aa4f","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym","parameters":[{"name":"Zakres","range":"± 2000 μm/m"},{"name":"Pomiar z zastosowaniem elektrycznej tensometrii oporowej"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej","reference":"PB5 wyd.6 z dnia 17.07.2026 r.","norm_bases":["PB5 wyd.6 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar odksztalcen jednostkowych przy obciazeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r.","categories":["construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of unit strains under dynamic load","parameters_en":[{"name":"Range","range":"± 2000 μm/m"},{"name":"Measurement using electrical resistance strain gauges"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of unit strains under dynamic load Aspekt Laboratorium Sp. z o.o. Range Measurement using electrical resistance strain gauges PB5 wyd.6 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","parameters_zh":[{"name":"范围","range":"± 2000 μm/m"},{"name":"采用电阻应变测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下单位变形的测量 Aspekt Laboratorium 有限责任公司 范围 采用电阻应变测量的测定 PB5 wyd.6 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"动荷载下单位变形的测量"},{"_id":"6a7d797e0636ba417e41aa50","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","methodology":"Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym","parameters":[{"name":"amplitud: ± 10 m/s2"},{"name":"częstotliwości","range":"(0.5 ÷ 100) Hz"},{"name":"Pomiar za pomocą akcelerometrów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczęstotliwości (0.5 ÷ 100) Hz\nPomiar za pomocą akcelerometrów","reference":"PB6 wyd.6 z dnia 17.07.2026 r.","norm_bases":["PB6 wyd.6 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczęstotliwości (0.5 ÷ 100) Hz\nPomiar za pomocą akcelerometrów PB6 wyd.6 z dnia 17.07.2026 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przyspieszen drgan elementow konstrukcji przy obciazeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczestotliwosci (0.5 ÷ 100) Hz\nPomiar za pomoca akcelerometrow PB6 wyd.6 z dnia 17.07.2026 r.","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of vibration accelerations of structural elements under dynamic loading","parameters_en":[{"name":"amplitudes: ± 10 m/s2"},{"name":"frequency","range":"(0.5 ÷ 100) Hz"},{"name":"Measurement using accelerometers"}],"search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vibration accelerations of structural elements under dynamic loading Aspekt Laboratorium Sp. z o.o. amplitudes: ± 10 m/s2 frequency Measurement using accelerometers PB6 wyd.6 z dnia 17.07.2026 r.","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下结构构件振动加速度的测量 Aspekt Laboratorium 有限责任公司 幅值：± 10 m/s2 频率 PB6 wyd.6 z dnia 17.07.2026 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","lab_section_zh":"Aspekt Laboratorium 有限责任公司","methodology_zh":"动荷载下结构构件振动加速度的测量","parameters_zh":[{"name":"幅值：± 10 m/s2"},{"name":"频率","range":"(0.5 ÷ 100) Hz"},{"name":"Pomiar za pomocą akcelerometrów"}]},{"_id":"6a7d797e0636ba417e41aa51","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane","methodology":"Pomiar odkształceń, Zakres pomiarowy: ± 2000 μm/m, Pomiar z zastosowaniem elektrycznej tensometrii oporowej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar odkształceń, Zakres pomiarowy: ± 2000 μm/m, Pomiar z zastosowaniem elektrycznej tensometrii oporowej","reference":"PB5 wyd.6 z dnia 17.07.2026 r.","norm_bases":["PB5 wyd.6 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane Pomiar odkształceń, Zakres pomiarowy: ± 2000 μm/m, Pomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r. Obiekty budowlane Pomiar odksztalcen, Zakres pomiarowy: ± 2000 μm/m, Pomiar z zastosowaniem elektrycznej tensometrii oporowej PB5 wyd.6 z dnia 17.07.2026 r.","categories":["construction"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Strain measurement, Measuring range: ± 2000 μm/m, Measurement using electrical resistance strain gauging","search_en":"Construction works Strain measurement, Measuring range: ± 2000 μm/m, Measurement using electrical resistance strain gauging Aspekt Laboratorium Sp. z o.o. PB5 wyd.6 z dnia 17.07.2026 r.","test_object_en":"Construction works","lab_section_zh":"Aspekt Laboratorium 有限责任公司","search_zh":"建筑物与构筑物 Aspekt Laboratorium 有限责任公司 PB5 wyd.6 z dnia 17.07.2026 r.","test_object_zh":"建筑物与构筑物"},{"_id":"6a7d797e0636ba417e41aa52","lab_id":"69ad52a3de79e566650fb6f8","country":"PL","accr_number":"AB 1359","accr_body":"PCA","test_object":"Obiekty budowlane","methodology":"Pomiar przyspieszeń drgań","parameters":[{"name":"amplituda: ± 10 m/s2"},{"name":"częstotliwość","range":"(0.5 ÷ 100) Hz"},{"name":"Pomiar za pomocą akcelerometrów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar przyspieszeń drgań\nZakres:\namplituda: ± 10 m/s2\nczęstotliwość (0.5 ÷ 100) Hz\nPomiar za pomocą akcelerometrów","reference":"PB6 wyd.6 z dnia 17.07.2026 r.","norm_bases":["PB6 wyd.6 z dnia 17.07.2026 r."],"lab_section":"Aspekt Laboratorium Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obiekty budowlane Pomiar przyspieszeń drgań\nZakres:\namplituda: ± 10 m/s2\nczęstotliwość (0.5 ÷ 100) Hz\nPomiar za pomocą akcelerometrów PB6 wyd.6 z dnia 17.07.2026 r. Obiekty budowlane Pomiar przyspieszen drgan\nZakres:\namplituda: ± 10 m/s2\nczestotliwosc (0.5 ÷ 100) Hz\nPomiar za pomoca akcelerometrow PB6 wyd.6 z dnia 17.07.2026 r.","categories":["construction"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Aspekt Laboratorium Sp. z o.o.","methodology_en":"Measurement of vibration accelerations","parameters_en":[{"name":"amplitude: ± 10 m/s2"},{"name":"frequency","range":"(0.5 ÷ 100) Hz"},{"name":"Measurement using accelerometers"}],"search_en":"Construction works Measurement of vibration accelerations Aspekt Laboratorium Sp. z o.o. amplitude: ± 10 m/s2 frequency Measurement using accelerometers PB6 wyd.6 z dnia 17.07.2026 r.","test_object_en":"Construction works","lab_section_zh":"Aspekt Laboratorium 有限责任公司","search_zh":"建筑物与构筑物 Aspekt Laboratorium 有限责任公司 PB6 wyd.6 z dnia 17.07.2026 r.","test_object_zh":"建筑物与构筑物"}],"has_pdf":true}