{"lab":{"_id":"69ad52a3de79e566650fb6f0","accr_number":"AB 1354","country":"PL","accr_body":"PCA","address":"ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki","categories":["construction","water"],"city":"Ożarów Mazowiecki","imported_at":"2026-03-08T10:42:43.265Z","methods_count":84,"name":"BARG CENTRUM Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1354.pdf"],"scope_summary":"","search_text":"barg centrum sp. z o.o. ul. kazimierza kamińskiego 28, 05-850 ożarów mazowiecki construction other materials pharma water environment electronics","status":"active","updated_at":"2026-03-08T14:50:31.767Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-20T00:38:36.031Z","email_confidence":"high","email_mx":true,"email_source":"https://barg.pl/en/contact/laboratory/mazowieckie/","parse_date":"2026-08-20T00:38:36.031Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów i materiałów budowlanych","en":"Mechanical tests and sampling of building products and building materials"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów i obiektów budowlanych","en":"Mechanical tests of building products and building items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów budowlanych, materiałów budowlanych i obiektów budowlanych","en":"Tests of physical properties and sampling of building products, building mterials and building items"},{"codes":"C/5/P","pl":"Badania chemiczne i pobieranie próbek materiałów budowlanych","en":"Chemical tests and sampling of building materials"}],"issue":{"no":"23","date":"18.08.2026"},"map_coord":[52.207996,20.801264],"map_geo":"nominatim-street","has_en":true,"lab_locations":[{"name":"Laboratorium Warszawa-Ożarów","address":"ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki","city":"Ożarów Mazowiecki","postal":"05-850"},{"name":"Laboratorium Warszawa-Delfina","address":"Ul. Delfina 4B, 03-196 Warszawa","city":"Warszawa","postal":"03-196"},{"name":"Laboratorium Łódź","address":"ul. Puszkina 80, 92-516 Łódź","city":"Łódź","postal":"92-516"},{"name":"Laboratorium Białystok","address":"Kolonia Koplany 29, 16-061 Juchnowiec Kościelny","city":"Juchnowiec Kościelny","postal":"16-061"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/19/ccdffa9de55a50177ceccb3b67bcfa38/AB%201354.pdf","category_counts":{"other":44,"construction":38,"water":8,"materials":1},"category_scores":{"other":21.27,"construction":15.87,"water":0.7,"materials":0.01},"has_zh":true},"methods":[{"_id":"6a864c8cfbf98dd0af9b1f6d","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a864c8cfbf98dd0af9b1f6e","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a864c8cfbf98dd0af9b1f6f","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda stolika rozpływowego","techniques":["Metoda stolika rozpływowego"],"computed":[],"activity":"Konsystencja\nMetoda stolika rozpływowego","reference":"PN-EN 12350-5:2019-08","norm_bases":["PN-EN 12350-5:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda stolika rozpływowego PN-EN 12350-5:2019-08 Mieszanka betonowa Konsystencja\nMetoda stolika rozplywowego PN-EN 12350-5:2019-08","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 跳桌法 PN-EN 12350-5:2019-08","test_object_zh":"混凝土拌合物","technique_zh":"跳桌法"},{"_id":"6a864c8cfbf98dd0af9b1f70","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0 - 10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nZakres (0 - 10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"(0 - 10) %"}],"search_zh":"混凝土拌合物 含气量 压力计法 范围 PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物"},{"_id":"6a864c8cfbf98dd0af9b1f71","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f72","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p.8.8","norm_bases":["PN-EN 932-1:1999 p.8.8"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p.8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p.8.8","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999 p.8.8","test_object_zh":"骨料"},{"_id":"6a864c8cfbf98dd0af9b1f73","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Stopień zagęszczenia (ld)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p.6 Grunty Stopien zageszczenia (ld)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p.6","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 轻型圆锥头触探仪法 PN-B-04452:2002 p.6","test_object_zh":"土体","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a864c8cfbf98dd0af9b1f74","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Podłoże","methodology":"Moduł odkształcenia","parameters":[],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Moduł odkształcenia\nMetoda obciążeń płytą VSS PN-S 02205:1998 Podloze Modul odksztalcenia\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"栽培基质 变形模量 VSS 平板荷载法 PN-S 02205:1998","test_object_zh":"栽培基质","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a864c8cfbf98dd0af9b1f75","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Podłoże","methodology":"Stopień zagęszczenia (ld)","parameters":[],"technique":"Metoda sondą lekką z końcówką stożkową","techniques":["Metoda sondą lekką z końcówką stożkową"],"computed":[],"activity":"Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową","reference":"PN-B-04452:2002 p.6","norm_bases":["PN-B-04452:2002 p.6"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Stopień zagęszczenia (ld)\nMetoda sondą lekką z końcówką stożkową PN-B-04452:2002 p.6 Podloze Stopien zageszczenia (ld)\nMetoda sonda lekka z koncowka stozkowa PN-B-04452:2002 p.6","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"栽培基质 轻型圆锥头触探仪法 PN-B-04452:2002 p.6","test_object_zh":"栽培基质","technique_zh":"轻型圆锥头触探仪法"},{"_id":"6a864c8cfbf98dd0af9b1f76","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Podłoże","methodology":"Dynamiczny moduł odkształcenia","parameters":[{"name":"Zakres","range":"(15-70) MN/m2"}],"technique":"Metoda lekką płytą dynamiczną","techniques":["Metoda lekką płytą dynamiczną"],"computed":[],"activity":"Dynamiczny moduł odkształcenia\nZakres (15-70) MN/m2\nMetoda lekką płytą dynamiczną","reference":"BC-PB-PD/PQ7.2","norm_bases":["BC-PB-PD/PQ7.2"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Dynamiczny moduł odkształcenia\nZakres (15-70) MN/m2\nMetoda lekką płytą dynamiczną BC-PB-PD/PQ7.2 Podloze Dynamiczny modul odksztalcenia\nZakres (15-70) MN/m2\nMetoda lekka plyta dynamiczna BC-PB-PD/PQ7.2","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(15-70) MN/m2"}],"search_zh":"栽培基质 动态变形模量 范围 BC-PB-PD/PQ7.2","test_object_zh":"栽培基质","methodology_zh":"动态变形模量"},{"_id":"6a864c8cfbf98dd0af9b1f77","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres","range":"(0,02 - 0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciążeń płytą VSS PN-S 02205:1998 Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciazen plyta VSS PN-S 02205:1998","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,02 - 0,45) MPa"}],"search_zh":"路面结构层 变形模量 VSS 平板荷载法 范围 PN-S 02205:1998","test_object_zh":"路面结构层","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a864c8cfbf98dd0af9b1f78","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Wyroby i systemy do ochrony i na-praw konstrukcji betonowych","methodology":"Przyczepność przez odrywanie","parameters":[{"name":"Zakres","range":"(1 - 16) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"computed":[],"activity":"Przyczepność przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off","reference":"PN-EN 1542:2000","norm_bases":["PN-EN 1542:2000"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i systemy do ochrony i na-praw konstrukcji betonowych Przyczepność przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN 1542:2000 Wyroby i systemy do ochrony i na-praw konstrukcji betonowych Przyczepnosc przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN 1542:2000","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1 - 16) kN"}],"search_zh":"拉拔法 范围 PN-EN 1542:2000","technique_zh":"拉拔法"},{"_id":"6a864c8cfbf98dd0af9b1f79","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Powłoki na podłożu betonowym i metalowym","methodology":"Przyczepność przez odrywanie","parameters":[{"name":"Zakres","range":"(1 - 16) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"computed":[],"activity":"Przyczepność przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off","reference":"PN-EN ISO 4624:2016-05 p.8.4.2","norm_bases":["PN-EN ISO 4624:2016-05 p.8.4.2"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powłoki na podłożu betonowym i metalowym Przyczepność przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN ISO 4624:2016-05 p.8.4.2 Powloki na podlozu betonowym i metalowym Przyczepnosc przez odrywanie\nZakres (1 - 16) kN\nMetoda pull-off PN-EN ISO 4624:2016-05 p.8.4.2","categories":["materials","construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1 - 16) kN"}],"search_zh":"拉拔法 范围 PN-EN ISO 4624:2016-05 p.8.4.2","technique_zh":"拉拔法"},{"_id":"6a864c8cfbf98dd0af9b1f7a","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12697-27:2017-07 p.4.7","norm_bases":["PN-EN 12697-27:2017-07 p.4.7"],"lab_section":"BARG Centrum Sp. z o.o.; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (działalność prowadzona w miejscu wskazanym przez Zleceniodawcę)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Pobieranie próbek PN-EN 12697-27:2017-07 p.4.7 Nawierzchnie drogowe (asfaltowe) Pobieranie probek PN-EN 12697-27:2017-07 p.4.7","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"样品采集","search_zh":"路面（沥青） 样品采集 PN-EN 12697-27:2017-07 p.4.7","test_object_zh":"路面（沥青）"},{"_id":"6a864c8cfbf98dd0af9b1f7b","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(50 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (50 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (50 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (50 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(50 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f7c","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(10 - 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (10 - 100) kN","reference":"PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres (10 - 100) kN PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres (10 - 100) kN PN-EN 12390-5:2019-08","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10 - 100) kN"}],"search_zh":"混凝土 抗弯强度 范围 PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度"},{"_id":"6a864c8cfbf98dd0af9b1f7d","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres","range":"(50 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (50 - 3000) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (50 - 3000) kN PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (50 - 3000) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(50 - 3000) kN"}],"search_zh":"混凝土 劈裂抗拉强度 范围 PN-EN 12390-6:2024-04","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f7e","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 p. 6.6","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f7f","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ci-śnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ci-śnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ci-śnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod ci-snieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f80","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu w obecności soli odladzającej","parameters":[],"technique":"Metoda slab test","techniques":["Metoda slab test"],"computed":[],"activity":"Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test","reference":"PKN-CEN/TS 12390-9:2017-07","norm_bases":["PKN-CEN/TS 12390-9:2017-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test PKN-CEN/TS 12390-9:2017-07 Beton Odpornosc na dzialanie mrozu w obecnosci soli odladzajacej\nMetoda slab test PKN-CEN/TS 12390-9:2017-07","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PKN-CEN/TS 12390-9:2017-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f81","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obec-no-ści soli odladzających","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obec-no-ści soli odladzających","reference":"PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08 Zał. O","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obec-no-ści soli odladzających PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc betonu na cykliczne za-mrazanie-rozmrazanie w obec-no-sci soli odladzajacych PN-B-06265:2022-08 Zal. O | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f82","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f83","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f84","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08 Zał. N","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-B-06265:2022-08 Zal. N | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a864c8cfbf98dd0af9b1f85","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(5 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (5 - 3000) kN","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres (5 - 3000) kN PN-EN 12504-1:2019-08 Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres (5 - 3000) kN PN-EN 12504-1:2019-08","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(5 - 3000) kN"}],"search_zh":"结构中的混凝土 抗压强度 范围 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a864c8cfbf98dd0af9b1f86","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 90) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 - 90) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a864c8cfbf98dd0af9b1f87","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 粉尘含量 筛分法 PN-EN 933-1:2012","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"粉尘含量"},{"_id":"6a864c8cfbf98dd0af9b1f88","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik płaskości","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik płaskości","reference":"PN-EN 933-3:2012","norm_bases":["PN-EN 933-3:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik płaskości PN-EN 933-3:2012 Kruszywa Wskaznik plaskosci PN-EN 933-3:2012","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 片状指数 PN-EN 933-3:2012","test_object_zh":"骨料","methodology_zh":"片状指数"},{"_id":"6a864c8cfbf98dd0af9b1f89","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn o powierzchni prze-kruszonej i łamanej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn o powierzchni prze-kruszonej i łamanej","reference":"PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","norm_bases":["PN-EN 933-5:2000","PN-EN 933-5:2000/A1:2005"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn o powierzchni prze-kruszonej i łamanej PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005 Kruszywa Zawartosc ziarn o powierzchni prze-kruszonej i lamanej PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 PN-EN 933-5:2000 | PN-EN 933-5:2000/A1:2005","test_object_zh":"骨料"},{"_id":"6a864c8cfbf98dd0af9b1f8a","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn przekruszonych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn przekruszonych","reference":"PN-EN 933-5:2023-05","norm_bases":["PN-EN 933-5:2023-05"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn przekruszonych PN-EN 933-5:2023-05 Kruszywa Zawartosc ziarn przekruszonych PN-EN 933-5:2023-05","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 压碎颗粒含量 PN-EN 933-5:2023-05","test_object_zh":"骨料","methodology_zh":"压碎颗粒含量"},{"_id":"6a864c8cfbf98dd0af9b1f8b","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 砂当量 PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","methodology_zh":"砂当量"},{"_id":"6a864c8cfbf98dd0af9b1f8c","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 抗破碎性 洛杉矶法 PN-EN 1097-2:2020-09","test_object_zh":"骨料","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a864c8cfbf98dd0af9b1f8d","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość nasypowa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa","reference":"PN-EN 1097-3:2000 z wył. Zał. A","norm_bases":["PN-EN 1097-3:2000 z wył. Zał. A"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość nasypowa PN-EN 1097-3:2000 z wył. Zał. A Kruszywa Gestosc nasypowa PN-EN 1097-3:2000 z wyl. Zal. A","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 堆积密度 PN-EN 1097-3:2000 z wył. Zał. A","test_object_zh":"骨料","methodology_zh":"堆积密度"},{"_id":"6a864c8cfbf98dd0af9b1f8e","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nMetoda wagowa","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość wody\nMetoda wagowa PN-EN 1097-5:2008 Kruszywa Zawartosc wody\nMetoda wagowa PN-EN 1097-5:2008","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"水分含量","search_zh":"骨料 水分含量 重量法 PN-EN 1097-5:2008","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a864c8cfbf98dd0af9b1f8f","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Nasiąkliwość PN-EN 1097-6:2022-07 Kruszywa Nasiakliwosc PN-EN 1097-6:2022-07","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"吸水率","search_zh":"骨料 吸水率 PN-EN 1097-6:2022-07","test_object_zh":"骨料"},{"_id":"6a864c8cfbf98dd0af9b1f90","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność w wodzie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność w wodzie","reference":"PN-EN 1367-1:2007","norm_bases":["PN-EN 1367-1:2007"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność w wodzie PN-EN 1367-1:2007 Kruszywa Mrozoodpornosc w wodzie PN-EN 1367-1:2007","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 水中抗冻性 PN-EN 1367-1:2007","test_object_zh":"骨料","methodology_zh":"水中抗冻性"},{"_id":"6a864c8cfbf98dd0af9b1f91","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym (Kruszywa)","methodology":"Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu\nMetoda Proctora","reference":"PN-EN 13286-2:2010 z wył. p.7.3 i p.7.6 | PN-EN 13286-2:2010/AC:2014-07","norm_bases":["PN-EN 13286-2:2010 z wył. p.7.3 i p.7.6","PN-EN 13286-2:2010/AC:2014-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym (Kruszywa) Optymalna zawartość wody oraz maksymalna gęstość objętościowa szkieletu\nMetoda Proctora PN-EN 13286-2:2010 z wył. p.7.3 i p.7.6 | PN-EN 13286-2:2010/AC:2014-07 Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym (Kruszywa) Optymalna zawartosc wody oraz maksymalna gestosc objetosciowa szkieletu\nMetoda Proctora PN-EN 13286-2:2010 z wyl. p.7.3 i p.7.6 | PN-EN 13286-2:2010/AC:2014-07","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"未结合与水硬性胶结料结合的混合料（集料） 普氏击实法 PN-EN 13286-2:2010 z wył. p.7.3 i p.7.6 | PN-EN 13286-2:2010/AC:2014-07","technique_zh":"普氏击实法","test_object_zh":"未结合与水硬性胶结料结合的混合料（集料）"},{"_id":"6a864c8cfbf98dd0af9b1f92","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa – zawartość frakcji","parameters":[{"name":"Zakres","range":"(0,063 – 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa – zawartość frakcji\nZakres (0,063 – 40) mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa – zawartość frakcji\nZakres (0,063 – 40) mm PN-88/B-04481 p.4.1 Grunty Analiza sitowa – zawartosc frakcji\nZakres (0,063 – 40) mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 – 40) mm"}],"search_zh":"土体 范围 PN-88/B-04481 p.4.1","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1f93","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji <0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji <0,063 mm","reference":"PN-88/B-04481 p.4.1","norm_bases":["PN-88/B-04481 p.4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji <0,063 mm PN-88/B-04481 p.4.1 Grunty Zawartosc frakcji <0,063 mm PN-88/B-04481 p.4.1","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 PN-88/B-04481 p.4.1","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1f94","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność\nMetoda wagowa","reference":"PN-88/B-04481 p.5.1","norm_bases":["PN-88/B-04481 p.5.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność\nMetoda wagowa PN-88/B-04481 p.5.1 Grunty Wilgotnosc\nMetoda wagowa PN-88/B-04481 p.5.1","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 湿度 重量法 PN-88/B-04481 p.5.1","technique_zh":"重量法","test_object_zh":"土体","methodology_zh":"湿度"},{"_id":"6a864c8cfbf98dd0af9b1f95","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu grun-towego","parameters":[],"technique":"Metoda Proctora (metoda I i II)","techniques":["Metoda Proctora (metoda I i II)"],"computed":[],"activity":"Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu grun-towego\nMetoda Proctora (metoda I i II)","reference":"PN-88/B-04481 p.8","norm_bases":["PN-88/B-04481 p.8"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu grun-towego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8 Grunty Wilgotnosc optymalna Maksymalna gestosc objetosciowa szkieletu grun-towego\nMetoda Proctora (metoda I i II) PN-88/B-04481 p.8","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 普氏击实法（方法 I 与 II） PN-88/B-04481 p.8","test_object_zh":"土体","technique_zh":"普氏击实法（方法 I 与 II）"},{"_id":"6a864c8cfbf98dd0af9b1f96","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość części organicznych","parameters":[],"technique":"Metoda wagowa (utleniania)","techniques":["Metoda wagowa (utleniania)"],"computed":[],"activity":"Zawartość części organicznych\nMetoda wagowa (utleniania)","reference":"PN-88/B-04481 p.4.4","norm_bases":["PN-88/B-04481 p.4.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość części organicznych\nMetoda wagowa (utleniania) PN-88/B-04481 p.4.4 Grunty Zawartosc czesci organicznych\nMetoda wagowa (utleniania) PN-88/B-04481 p.4.4","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 有机组分含量 PN-88/B-04481 p.4.4","test_object_zh":"土体","methodology_zh":"有机组分含量"},{"_id":"6a864c8cfbf98dd0af9b1f97","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Kapilarność bierna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kapilarność bierna","reference":"PN-60/B-04493","norm_bases":["PN-60/B-04493"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Kapilarność bierna PN-60/B-04493 Grunty Kapilarnosc bierna PN-60/B-04493","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 被动毛细吸水性 PN-60/B-04493","test_object_zh":"土体","methodology_zh":"被动毛细吸水性"},{"_id":"6a864c8cfbf98dd0af9b1f98","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik nośności wnoś","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności wnoś","reference":"PN-S 02205:1998","norm_bases":["PN-S 02205:1998"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik nośności wnoś PN-S 02205:1998 Grunty Wskaznik nosnosci wnos PN-S 02205:1998","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 PN-S 02205:1998","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1f99","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6","BN-77/8931-12 p.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4 Grunty Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 压实指数（ls） 压入圆筒法 PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","test_object_zh":"土体","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"},{"_id":"6a864c8cfbf98dd0af9b1f9a","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunt stabilizowany cementem","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(2 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (2 - 50) kN","reference":"PN-S 96012:1997","norm_bases":["PN-S 96012:1997"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunt stabilizowany cementem Wytrzymałość na ściskanie\nZakres (2 - 50) kN PN-S 96012:1997 Grunt stabilizowany cementem Wytrzymalosc na sciskanie\nZakres (2 - 50) kN PN-S 96012:1997","categories":["construction"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(2 - 50) kN"}],"search_zh":"水泥稳定土 抗压强度 范围 PN-S 96012:1997","test_object_zh":"水泥稳定土"},{"_id":"6a864c8cfbf98dd0af9b1f9b","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Podłoże","methodology":"Wskaźnik zagęszczenia (ls)","parameters":[],"technique":"Metoda cylindra wciskanego","techniques":["Metoda cylindra wciskanego"],"computed":[],"activity":"Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego","reference":"PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","norm_bases":["PN-88/B-04481 p.5.2.6","BN-77/8931-12 p.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Wskaźnik zagęszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4 Podloze Wskaznik zageszczenia (ls)\nMetoda cylindra wciskanego PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"栽培基质 压实指数（ls） 压入圆筒法 PN-88/B-04481 p.5.2.6 | BN-77/8931-12 p.4","test_object_zh":"栽培基质","methodology_zh":"压实指数（ls）","technique_zh":"压入圆筒法"},{"_id":"6a864c8cfbf98dd0af9b1f9c","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego","reference":"PN-EN 12697-1:2020-08 p.B.1.7","norm_bases":["PN-EN 12697-1:2020-08 p.B.1.7"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Zawartość lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08 p.B.1.7 Mieszanki mineralno-asfaltowe Zawartosc lepiszcza rozpuszczalnego PN-EN 12697-1:2020-08 p.B.1.7","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"沥青混合料 可溶性胶结料含量 PN-EN 12697-1:2020-08 p.B.1.7","test_object_zh":"沥青混合料","methodology_zh":"可溶性胶结料含量"},{"_id":"6a864c8cfbf98dd0af9b1f9d","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Uziarnienie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uziarnienie","reference":"PN-EN 12697-2:2025-06","norm_bases":["PN-EN 12697-2:2025-06"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Uziarnienie PN-EN 12697-2:2025-06 Mieszanki mineralno-asfaltowe Uziarnienie PN-EN 12697-2:2025-06","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"沥青混合料 级配 PN-EN 12697-2:2025-06","test_object_zh":"沥青混合料","methodology_zh":"级配"},{"_id":"6a864c8cfbf98dd0af9b1f9e","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość w wodzie","parameters":[],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Gęstość w wodzie\nMetoda A","reference":"PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2019-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość w wodzie\nMetoda A PN-EN 12697-5:2019-01 Mieszanki mineralno-asfaltowe Gestosc w wodzie\nMetoda A PN-EN 12697-5:2019-01","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"沥青混合料 水中密度 方法 A PN-EN 12697-5:2019-01","test_object_zh":"沥青混合料","methodology_zh":"水中密度","technique_zh":"方法 A"},{"_id":"6a864c8cfbf98dd0af9b1f9f","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda B","techniques":["Metoda B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda B","reference":"PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2020-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość objętościowa\nMetoda B PN-EN 12697-6:2020-07 Mieszanki mineralno-asfaltowe Gestosc objetosciowa\nMetoda B PN-EN 12697-6:2020-07","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"沥青混合料 堆积密度 方法 B PN-EN 12697-6:2020-07","test_object_zh":"沥青混合料","methodology_zh":"堆积密度","technique_zh":"方法 B"},{"_id":"6a864c8cfbf98dd0af9b1fa0","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Zawartość wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2019-07 p.4","norm_bases":["PN-EN 12697-8:2019-07 p.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Zawartość wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2019-07 p.4 Mieszanki mineralno-asfaltowe Zawartosc wolnej przestrzeni (z obliczen) PN-EN 12697-8:2019-07 p.4","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"沥青混合料 空隙率（计算值） PN-EN 12697-8:2019-07 p.4","test_object_zh":"沥青混合料","methodology_zh":"空隙率（计算值）"},{"_id":"6a864c8cfbf98dd0af9b1fa1","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Gęstość w wodzie","parameters":[],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Gęstość w wodzie\nMetoda A","reference":"PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2019-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Gęstość w wodzie\nMetoda A PN-EN 12697-5:2019-01 Nawierzchnie drogowe (asfaltowe) Gestosc w wodzie\nMetoda A PN-EN 12697-5:2019-01","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"水中密度","search_zh":"路面（沥青） 水中密度 方法 A PN-EN 12697-5:2019-01","test_object_zh":"路面（沥青）","technique_zh":"方法 A"},{"_id":"6a864c8cfbf98dd0af9b1fa2","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda B","techniques":["Metoda B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda B","reference":"PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2020-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Gęstość objętościowa\nMetoda B PN-EN 12697-6:2020-07 Nawierzchnie drogowe (asfaltowe) Gestosc objetosciowa\nMetoda B PN-EN 12697-6:2020-07","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"堆积密度","search_zh":"路面（沥青） 堆积密度 方法 B PN-EN 12697-6:2020-07","test_object_zh":"路面（沥青）","technique_zh":"方法 B"},{"_id":"6a864c8cfbf98dd0af9b1fa3","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Zawartość wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2019-07 p.4","norm_bases":["PN-EN 12697-8:2019-07 p.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Zawartość wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2019-07 p.4 Nawierzchnie drogowe (asfaltowe) Zawartosc wolnej przestrzeni (z obliczen) PN-EN 12697-8:2019-07 p.4","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空隙率（计算值）","search_zh":"路面（沥青） 空隙率（计算值） PN-EN 12697-8:2019-07 p.4","test_object_zh":"路面（沥青）"},{"_id":"6a864c8cfbf98dd0af9b1fa4","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Nawierzchnie drogowe (asfaltowe)","methodology":"Wskaźnik zagęszczenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik zagęszczenia (z obliczeń)","reference":"PN-EN 13108-20:2016-07 Zał. C.4","norm_bases":["PN-EN 13108-20:2016-07 Zał. C.4"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Ożarów; ul. Kazimierza Kamińskiego 28, 05-850 Ożarów Mazowiecki; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe (asfaltowe) Wskaźnik zagęszczenia (z obliczeń) PN-EN 13108-20:2016-07 Zał. C.4 Nawierzchnie drogowe (asfaltowe) Wskaznik zageszczenia (z obliczen) PN-EN 13108-20:2016-07 Zal. C.4","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"路面（沥青） 压实指数（由计算得出） PN-EN 13108-20:2016-07 Zał. C.4","test_object_zh":"路面（沥青）","methodology_zh":"压实指数（由计算得出）"},{"_id":"6a864c8cfbf98dd0af9b1fa5","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(100 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Delfina; Ul. Delfina 4B, 03-196 Warszawa; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fa6","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 p. 6.6","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Warszawa-Delfina; Ul. Delfina 4B, 03-196 Warszawa; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fa7","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(30 - 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (30 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (30 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (30 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(30 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fa8","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 p. 6.6","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fa9","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(2 - 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (2 - 100) kN","reference":"PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres (2 - 100) kN PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres (2 - 100) kN PN-EN 12390-5:2019-08","categories":["construction"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2 - 100) kN"}],"search_zh":"混凝土 抗弯强度 范围 PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度"},{"_id":"6a864c8cfbf98dd0af9b1faa","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres","range":"(30 - 500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (30 - 500) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (30 - 500) kN PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (30 - 500) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(30 - 500) kN"}],"search_zh":"混凝土 劈裂抗拉强度 范围 PN-EN 12390-6:2024-04","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fab","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ci-śnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ci-śnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ci-śnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod ci-snieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fac","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu w obecności soli odladzającej","parameters":[],"technique":"Metoda slab test","techniques":["Metoda slab test"],"computed":[],"activity":"Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test","reference":"PKN-CEN/TS 12390-9:2017-07","norm_bases":["PKN-CEN/TS 12390-9:2017-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu w obecności soli odladzającej\nMetoda slab test PKN-CEN/TS 12390-9:2017-07 Beton Odpornosc na dzialanie mrozu w obecnosci soli odladzajacej\nMetoda slab test PKN-CEN/TS 12390-9:2017-07","categories":["construction"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PKN-CEN/TS 12390-9:2017-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fad","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obecności soli odladzających","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obecności soli odladzających","reference":"PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08 Zał. O","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność betonu na cykliczne za-mrażanie-rozmrażanie w obecności soli odladzających PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc betonu na cykliczne za-mrazanie-rozmrazanie w obecnosci soli odladzajacych PN-B-06265:2022-08 Zal. O | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PN-B-06265:2022-08 Zał. O | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fae","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1faf","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fb0","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08","norm_bases":["PN-B-06265:2022-08 Zał. N","PN-B-06265:2022-08/Az1:2025-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08 Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-B-06265:2022-08 Zal. N | PN-B-06265:2022-08/Az1:2025-08","categories":["construction"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-B-06265:2022-08 Zał. N | PN-B-06265:2022-08/Az1:2025-08","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a864c8cfbf98dd0af9b1fb1","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 - 63) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a864c8cfbf98dd0af9b1fb2","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 粉尘含量 筛分法 PN-EN 933-1:2012","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"粉尘含量"},{"_id":"6a864c8cfbf98dd0af9b1fb3","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa – zawartość frakcji","parameters":[{"name":"Zakres","range":"(0,063 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm","reference":"PN-88/B-04481 p. 4.1","norm_bases":["PN-88/B-04481 p. 4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p. 4.1 Grunty Analiza sitowa – zawartosc frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p. 4.1","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 - 40) mm"}],"search_zh":"土体 范围 PN-88/B-04481 p. 4.1","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1fb4","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji <0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji <0,063 mm","reference":"PN-88/B-04481 p. 4.1","norm_bases":["PN-88/B-04481 p. 4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji <0,063 mm PN-88/B-04481 p. 4.1 Grunty Zawartosc frakcji <0,063 mm PN-88/B-04481 p. 4.1","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 PN-88/B-04481 p. 4.1","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1fb5","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunt stabilizowany cementem","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(2 - 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (2 - 50) kN","reference":"PN-S 96012:1997","norm_bases":["PN-S 96012:1997"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Łódź; ul. Puszkina 80, 92-516 Łódź; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunt stabilizowany cementem Wytrzymałość na ściskanie\nZakres (2 - 50) kN PN-S 96012:1997 Grunt stabilizowany cementem Wytrzymalosc na sciskanie\nZakres (2 - 50) kN PN-S 96012:1997","categories":["construction"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(2 - 50) kN"}],"search_zh":"水泥稳定土 抗压强度 范围 PN-S 96012:1997","test_object_zh":"水泥稳定土"},{"_id":"6a864c8cfbf98dd0af9b1fb6","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(50 – 2800) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (50 – 2800) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (50 – 2800) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (50 – 2800) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(50 – 2800) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fb7","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda określenia objętości próbki na podstawie wymiarów","techniques":["Metoda określenia objętości próbki na podstawie wymiarów"],"computed":[],"activity":"Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów","reference":"PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 p. 6.6","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda określenia objętości próbki na podstawie wymiarów PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda okreslenia objetosci probki na podstawie wymiarow PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 p. 6.6 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fb8","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ci-śnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ci-śnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ci-śnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod ci-snieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"混凝土 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fb9","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fba","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土"},{"_id":"6a864c8cfbf98dd0af9b1fbb","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-B-06265:2022-08 Zał. N","norm_bases":["PN-B-06265:2022-08 Zał. N"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-B-06265:2022-08 Zał. N Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-B-06265:2022-08 Zal. N","categories":["construction"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-B-06265:2022-08 Zał. N","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a864c8cfbf98dd0af9b1fbc","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 - 90) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 - 90) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 - 90) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a864c8cfbf98dd0af9b1fbd","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość pyłów","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Zawartość pyłów\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość pyłów\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Zawartosc pylow\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 粉尘含量 筛分法 PN-EN 933-1:2012","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"粉尘含量"},{"_id":"6a864c8cfbf98dd0af9b1fbe","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na ścieranie","parameters":[],"technique":"Metoda mikro-Deval","techniques":["Metoda mikro-Deval"],"computed":[],"activity":"Odporność na ścieranie\nMetoda mikro-Deval","reference":"PN-EN 1097-1:2011","norm_bases":["PN-EN 1097-1:2011"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na ścieranie\nMetoda mikro-Deval PN-EN 1097-1:2011 Kruszywa Odpornosc na scieranie\nMetoda mikro-Deval PN-EN 1097-1:2011","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"骨料 耐磨性 微 Deval 法 PN-EN 1097-1:2011","test_object_zh":"骨料","methodology_zh":"耐磨性","technique_zh":"微 Deval 法"},{"_id":"6a864c8cfbf98dd0af9b1fbf","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Analiza sitowa – zawartość frakcji","parameters":[{"name":"Zakres","range":"(0,063 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm","reference":"PN-88/B-04481 p. 4.1","norm_bases":["PN-88/B-04481 p. 4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Analiza sitowa – zawartość frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p. 4.1 Grunty Analiza sitowa – zawartosc frakcji\nZakres (0,063 - 40) mm PN-88/B-04481 p. 4.1","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 - 40) mm"}],"search_zh":"土体 范围 PN-88/B-04481 p. 4.1","test_object_zh":"土体"},{"_id":"6a864c8cfbf98dd0af9b1fc0","lab_id":"69ad52a3de79e566650fb6f0","country":"PL","accr_number":"AB 1354","accr_body":"PCA","test_object":"Grunty","methodology":"Zawartość frakcji <0,063 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji <0,063 mm","reference":"PN-88/B-04481 p. 4.1","norm_bases":["PN-88/B-04481 p. 4.1"],"lab_section":"BARG Centrum Sp. z o.o.; Laboratorium Białystok; Kolonia Koplany 29, 16-061 Juchnowiec Kościelny; (stacjonarna działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Zawartość frakcji <0,063 mm PN-88/B-04481 p. 4.1 Grunty Zawartosc frakcji <0,063 mm PN-88/B-04481 p. 4.1","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"土体 PN-88/B-04481 p. 4.1","test_object_zh":"土体"}],"has_pdf":true}