{"lab":{"_id":"69ad52a3de79e566650fb137","accr_number":"AB 134","country":"PL","accr_body":"PCA","address":"LABORATORIUM POMIARÓW CIŚNIENIA, ul. Księcia Bolesława 6, 01-494 Warszawa","categories":["other"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":6,"name":"INSTYTUT TECHNICZNY WOJSK LOTNICZYCH","parse_status":"parsed","parse_version":2,"pdf_files":["AB_134.pdf"],"scope_summary":"","search_text":"instytut techniczny wojsk lotniczych laboratorium pomiarów ciśnienia, ul. księcia bolesława 6, 01-494 warszawa other","status":"active","updated_at":"2026-03-08T14:50:30.765Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:30.765Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20134,podmiot.html","parse_date":"2026-07-17T16:19:04.062Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"J/13","pl":"Badania mechaniczne wyposażenia","en":"Mechanical tests of equipment","de":"Mechanische Prüfungen von Ausrüstung","zh":"设备的力学检测","cs":"Mechanické zkoušky vybavení"},{"codes":"N/13","pl":"Badania właściwości fizycznych wyposażenia","en":"Tests of physical properties of equipment","de":"Prüfungen physikalischer Eigenschaften von Ausrüstung","zh":"设备的物理性能检测","cs":"Zkoušky fyzikálních vlastností vybavení"}],"issue":{"no":"13","date":"18.09.2023"},"map_coord":[52.252124,20.934482],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":6},"category_scores":{"other":6},"has_zh":true,"has_de":true,"has_cs":true,"pelny_cs":true},"methods":[{"_id":"6a5a55f89af9f73f382522e7","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Zbiorniki zamknięte","test_object_en":"Closed tanks","methodology":"Ciśnienie w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","methodology_en":"Pressure in the range: (-0,1 – +250) MPa Direct method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciśnienie w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","reference":"PB-43-04 edycja 3 z dnia 16.09.2021 r.","norm_bases":["PB-43-04 edycja 3 z dnia 16.09.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zbiorniki zamknięte Ciśnienie w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia PB-43-04 edycja 3 z dnia 16.09.2021 r. Zbiorniki zamkniete Cisnienie w zakresie: (-0,1 – +250) MPa Metoda bezposrednia PB-43-04 edycja 3 z dnia 16.09.2021 r.","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Closed tanks Pressure in the range: (-0,1 – +250) MPa Direct method PB-43-04 edition 3 of 16.09.2021","methodology_de":"Druck im Bereich: (-0,1 – +250) MPa Direktes Verfahren","search_de":"Geschlossene Behälter Druck im Bereich: (-0,1 – +250) MPa Direktes Verfahren PB-43-04 Ausgabe 3 vom 16.09.2021","test_object_de":"Geschlossene Behälter","methodology_zh":"压力，范围：(-0,1 – +250) MPa 直接法","search_zh":"封闭容器 压力，范围：(-0,1 – +250) MPa 直接法 PB-43-04 第3版（2021年9月16日）","test_object_zh":"封闭容器","reference_en":"PB-43-04 edition 3 of 16.09.2021","reference_de":"PB-43-04 Ausgabe 3 vom 16.09.2021","reference_zh":"PB-43-04 第3版（2021年9月16日）","methodology_cs":"Tlak v rozsahu: (-0,1 – +250) MPa Přímá metoda","reference_cs":"PB-43-04 vydání 3 ze dne 16.09.2021","search_cs":"Uzavřené nádrže Tlak v rozsahu: (-0,1 – +250) MPa Přímá metoda PB-43-04 vydání 3 ze dne 16.09.2021","test_object_cs":"Uzavřené nádrže"},{"_id":"6a5a55f89af9f73f382522e8","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Zbiorniki zamknięte","test_object_en":"Closed tanks","methodology":"Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","methodology_en":"Tightness in the range: (-0,1 – +250) MPa Direct method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zbiorniki zamknięte Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia Zbiorniki zamkniete Szczelnosc w zakresie: (-0,1 – +250) MPa Metoda bezposrednia","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Closed tanks Tightness in the range: (-0,1 – +250) MPa Direct method","methodology_de":"Dichtheit im Bereich: (-0,1 – +250) MPa Direktes Verfahren","search_de":"Geschlossene Behälter Dichtheit im Bereich: (-0,1 – +250) MPa Direktes Verfahren","test_object_de":"Geschlossene Behälter","methodology_zh":"密封性范围：(-0,1 – +250) MPa 直接法","search_zh":"封闭容器 密封性范围：(-0,1 – +250) MPa 直接法","test_object_zh":"封闭容器","methodology_cs":"Těsnost v rozsahu: (-0,1 – +250) MPa Přímá metoda","search_cs":"Uzavřené nádrže Těsnost v rozsahu: (-0,1 – +250) MPa Přímá metoda","test_object_cs":"Uzavřené nádrže"},{"_id":"6a5a55f89af9f73f382522e9","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe","test_object_en":"Bourdon tube pressure gauges","methodology":"Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","methodology_en":"Tightness in the range: (-0,1 – +250) MPa Direct method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia","reference":"PB-43-05 edycja 3 z dnia 16.09.2021 r.","norm_bases":["PB-43-05 edycja 3 z dnia 16.09.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciśnieniomierze sprężynowe Szczelność w zakresie: (-0,1 – +250) MPa Metoda bezpośrednia PB-43-05 edycja 3 z dnia 16.09.2021 r. Cisnieniomierze sprezynowe Szczelnosc w zakresie: (-0,1 – +250) MPa Metoda bezposrednia PB-43-05 edycja 3 z dnia 16.09.2021 r.","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bourdon tube pressure gauges Tightness in the range: (-0,1 – +250) MPa Direct method PB-43-05 edition 3 of 16.09.2021","search_zh":"弹簧管压力表 密封性范围：(-0,1 – +250) MPa 直接法 PB-43-05 第3版（2021年9月16日）","test_object_zh":"弹簧管压力表","methodology_de":"Dichtheit im Bereich: (-0,1 – +250) MPa Direktes Verfahren","search_de":"Federmanometer Dichtheit im Bereich: (-0,1 – +250) MPa Direktes Verfahren PB-43-05 Ausgabe 3 vom 16.09.2021","test_object_de":"Federmanometer","methodology_zh":"密封性范围：(-0,1 – +250) MPa 直接法","reference_en":"PB-43-05 edition 3 of 16.09.2021","reference_de":"PB-43-05 Ausgabe 3 vom 16.09.2021","reference_zh":"PB-43-05 第3版（2021年9月16日）","search_cs":"Deformační tlakoměry Těsnost v rozsahu: (-0,1 – +250) MPa Přímá metoda PB-43-05 vydání 3 ze dne 16.09.2021","test_object_cs":"Deformační tlakoměry","methodology_cs":"Těsnost v rozsahu: (-0,1 – +250) MPa Přímá metoda","reference_cs":"PB-43-05 vydání 3 ze dne 16.09.2021"},{"_id":"6a5a55f89af9f73f382522ea","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe","test_object_en":"Bourdon tube pressure gauges","methodology":"Wymiary geometryczne Zakres: (0 –150) mm Metoda bezpośrednia","methodology_en":"Geometric dimensions Range: (0 –150) mm Direct method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne Zakres: (0 –150) mm Metoda bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciśnieniomierze sprężynowe Wymiary geometryczne Zakres: (0 –150) mm Metoda bezpośrednia Cisnieniomierze sprezynowe Wymiary geometryczne Zakres: (0 –150) mm Metoda bezposrednia","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bourdon tube pressure gauges Geometric dimensions Range: (0 –150) mm Direct method","search_zh":"弹簧管压力表 几何尺寸 范围：(0 –150) mm 直接法","test_object_zh":"弹簧管压力表","methodology_de":"Geometrische Abmessungen Bereich: (0 –150) mm Direktes Verfahren","search_de":"Federmanometer Geometrische Abmessungen Bereich: (0 –150) mm Direktes Verfahren","test_object_de":"Federmanometer","methodology_zh":"几何尺寸 范围：(0 –150) mm 直接法","search_cs":"Deformační tlakoměry Geometrické rozměry Rozsah: (0 –150) mm Přímá metoda","test_object_cs":"Deformační tlakoměry","methodology_cs":"Geometrické rozměry Rozsah: (0 –150) mm Přímá metoda"},{"_id":"6a5a55f89af9f73f382522eb","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe","test_object_en":"Bourdon tube pressure gauges","methodology":"Przesłanianie kresek podziałki","methodology_en":"Obscuring of the scale marks","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przesłanianie kresek podziałki","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciśnieniomierze sprężynowe Przesłanianie kresek podziałki Cisnieniomierze sprezynowe Przeslanianie kresek podzialki","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bourdon tube pressure gauges Obscuring of the scale marks","search_zh":"弹簧管压力表 刻度线遮挡","test_object_zh":"弹簧管压力表","methodology_de":"Überdeckung der Teilstriche","search_de":"Federmanometer Überdeckung der Teilstriche","test_object_de":"Federmanometer","methodology_zh":"刻度线遮挡","search_cs":"Deformační tlakoměry Zakrývání rysek stupnice","test_object_cs":"Deformační tlakoměry","methodology_cs":"Zakrývání rysek stupnice"},{"_id":"6a5a55f89af9f73f382522ec","lab_id":"69ad52a3de79e566650fb137","country":"PL","accr_number":"AB 134","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe","test_object_en":"Bourdon tube pressure gauges","methodology":"Płynność ruchu wskazówki","methodology_en":"Smoothness of pointer movement","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Płynność ruchu wskazówki","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciśnieniomierze sprężynowe Płynność ruchu wskazówki Cisnieniomierze sprezynowe Plynnosc ruchu wskazowki","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Bourdon tube pressure gauges Smoothness of pointer movement","search_zh":"弹簧管压力表 指针运动平稳性","test_object_zh":"弹簧管压力表","methodology_de":"Gleichmäßigkeit der Zeigerbewegung","search_de":"Federmanometer Gleichmäßigkeit der Zeigerbewegung","test_object_de":"Federmanometer","methodology_zh":"指针运动平稳性","search_cs":"Deformační tlakoměry Plynulost pohybu ručky","test_object_cs":"Deformační tlakoměry","methodology_cs":"Plynulost pohybu ručky"}],"has_pdf":true}