{"lab":{"_id":"69ad52a3de79e566650fb135","accr_number":"AB 133","country":"PL","accr_body":"PCA","address":"LABORATORIUM NARAŻEŃ MECHANICZNYCH I KLIMATYCZNYCH, ul. Księcia Bolesława 6","categories":["environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":3,"name":"INSTYTUT TECHNICZNY WOJSK LOTNICZYCH","parse_status":"parsed","parse_version":2,"pdf_files":["AB_133.pdf"],"scope_summary":"","search_text":"instytut techniczny wojsk lotniczych laboratorium narażeń mechanicznych i klimatycznych, ul. księcia bolesława 6 environment materials other","status":"active","updated_at":"2026-03-08T14:50:30.248Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:30.248Z","email_confidence":"high","email_mx":true,"email_source":"https://www.itwl.pl/kontakt","parse_date":"2026-07-17T16:19:03.742Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"G/13","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) urządzeń","en":"Tests concerning environmental engineering (environmental and climatic) of devices","de":"Prüfungen der Umwelttechnik (Umwelt- und Klimaprüfungen) von Geräten","zh":"设备的环境工程检测（环境和气候）","cs":"Zkoušky v oblasti environmentálního inženýrství (environmentální a klimatické) zařízení"}],"issue":{"no":"10","date":"06.11.2025"},"map_coord":[52.252124,20.934482],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":3},"category_scores":{"environment":3},"has_zh":true,"has_de":true,"pelny_cs":true,"has_cs":true},"methods":[{"_id":"6a5a55f79af9f73f382521bf","lab_id":"69ad52a3de79e566650fb135","country":"PL","accr_number":"AB 133","accr_body":"PCA","test_object":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm","test_object_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm","methodology":"Parametr narażenia w komorze klimatycznej – Ciśnienie Zakres: od 35 hPa do 1020 hPa","methodology_en":"Exposure parameter in the climatic chamber – Pressure Range: from 35 hPa to 1020 hPa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametr narażenia w komorze klimatycznej – Ciśnienie Zakres: od 35 hPa do 1020 hPa","reference":"NO-06-A107:2005 p. 4.6, p. 4.7, p. 4.9, p. 5.3 NO-06-A107:2021 p. 4.6, 4.7, 4.9, 5.3","norm_bases":["NO-06-A107:2005 p. 4.6, p. 4.7, p. 4.9, p. 5.3 NO-06-A107:2021 p. 4.6, 4.7, 4.9, 5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narażenia w komorze klimatycznej – Ciśnienie Zakres: od 35 hPa do 1020 hPa NO-06-A107:2005 p. 4.6, p. 4.7, p. 4.9, p. 5.3 NO-06-A107:2021 p. 4.6, 4.7, 4.9, 5.3 Srodowisko do celow narazen klimatycznych dla urzadzen technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narazenia w komorze klimatycznej – Cisnienie Zakres: od 35 hPa do 1020 hPa NO-06-A107:2005 p. 4.6, p. 4.7, p. 4.9, p. 5.3 NO-06-A107:2021 p. 4.6, 4.7, 4.9, 5.3","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm Exposure parameter in the climatic chamber – Pressure Range: from 35 hPa to 1020 hPa NO-06-A107:2005 cl. 4.6, cl. 4.7, cl. 4.9, cl. 5.3 NO-06-A107:2021 cl. 4.6, 4.7, 4.9, 5.3","search_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境 气候试验箱暴露参数 – 压力 范围：自 35 hPa 至 1020 hPa NO-06-A107:2005 第4.6条, 第4.7条, 第4.9条, 第5.3条 NO-06-A107:2021 第4.6条, 4.7, 4.9, 5.3","test_object_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境","methodology_de":"Beanspruchungsparameter in der Klimakammer – Druck Bereich: von 35 hPa bis 1020 hPa","search_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm Beanspruchungsparameter in der Klimakammer – Druck Bereich: von 35 hPa bis 1020 hPa NO-06-A107:2005 Abschn. 4.6, Abschn. 4.7, Abschn. 4.9, Abschn. 5.3 NO-06-A107:2021 Abschn. 4.6, 4.7, 4.9, 5.3","test_object_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm","methodology_zh":"气候试验箱暴露参数 – 压力 范围：自 35 hPa 至 1020 hPa","reference_en":"NO-06-A107:2005 cl. 4.6, cl. 4.7, cl. 4.9, cl. 5.3 NO-06-A107:2021 cl. 4.6, 4.7, 4.9, 5.3","reference_de":"NO-06-A107:2005 Abschn. 4.6, Abschn. 4.7, Abschn. 4.9, Abschn. 5.3 NO-06-A107:2021 Abschn. 4.6, 4.7, 4.9, 5.3","reference_zh":"NO-06-A107:2005 第4.6条, 第4.7条, 第4.9条, 第5.3条 NO-06-A107:2021 第4.6条, 4.7, 4.9, 5.3","methodology_cs":"Parametr namáhání v klimatické komoře – Tlak Rozsah: od 35 hPa do 1020 hPa","reference_cs":"NO-06-A107:2005 čl. 4.6, čl. 4.7, čl. 4.9, čl. 5.3 NO-06-A107:2021 čl. 4.6, 4.7, 4.9, 5.3","search_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm Parametr namáhání v klimatické komoře – Tlak Rozsah: od 35 hPa do 1020 hPa NO-06-A107:2005 čl. 4.6, čl. 4.7, čl. 4.9, čl. 5.3 NO-06-A107:2021 čl. 4.6, 4.7, 4.9, 5.3","test_object_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm"},{"_id":"6a5a55f79af9f73f382521c0","lab_id":"69ad52a3de79e566650fb135","country":"PL","accr_number":"AB 133","accr_body":"PCA","test_object":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm","test_object_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm","methodology":"Parametr narażenia w komorze klimatycznej – Temperatura Zakres: od -60 °C do +100 °C","methodology_en":"Exposure parameter in the climatic chamber – Temperature Range: from -60 °C to +100 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametr narażenia w komorze klimatycznej – Temperatura Zakres: od -60 °C do +100 °C","reference":"NO-06-A107:2005 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91) NO-06-A107:2021 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91)","norm_bases":["NO-06-A107:2005 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91) NO-06-A107:2021 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narażenia w komorze klimatycznej – Temperatura Zakres: od -60 °C do +100 °C NO-06-A107:2005 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91) NO-06-A107:2021 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91) Srodowisko do celow narazen klimatycznych dla urzadzen technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narazenia w komorze klimatycznej – Temperatura Zakres: od -60 °C do +100 °C NO-06-A107:2005 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91) NO-06-A107:2021 p. 4.2, p. 4.3, p. 4.5.3, p. 4.5.4, p. 5.6, p. 5.7, p. 5.8, p. 5.91)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm Exposure parameter in the climatic chamber – Temperature Range: from -60 °C to +100 °C NO-06-A107:2005 cl. 4.2, cl. 4.3, cl. 4.5.3, cl. 4.5.4, cl. 5.6, cl. 5.7, cl. 5.8, cl. 5.91) NO-06-A107:2021 cl. 4.2, cl. 4.3, cl. 4.5.3, cl. 4.5.4, cl. 5.6, cl. 5.7, cl. 5.8, cl. 5.91)","search_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境 气候试验箱暴露参数 – 温度 范围：自 -60 °C 至 +100 °C NO-06-A107:2005 第4.2条, 第4.3条, 第4.5.3条, 第4.5.4条, 第5.6条, 第5.7条, 第5.8条, 第5.91条) NO-06-A107:2021 第4.2条, 第4.3条, 第4.5.3条, 第4.5.4条, 第5.6条, 第5.7条, 第5.8条, 第5.91条)","test_object_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境","methodology_de":"Beanspruchungsparameter in der Klimakammer – Temperatur Bereich: von -60 °C bis +100 °C","search_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm Beanspruchungsparameter in der Klimakammer – Temperatur Bereich: von -60 °C bis +100 °C NO-06-A107:2005 Abschn. 4.2, Abschn. 4.3, Abschn. 4.5.3, Abschn. 4.5.4, Abschn. 5.6, Abschn. 5.7, Abschn. 5.8, Abschn. 5.91) NO-06-A107:2021 Abschn. 4.2, Abschn. 4.3, Abschn. 4.5.3, Abschn. 4.5.4, Abschn. 5.6, Abschn. 5.7, Abschn. 5.8, Abschn. 5.91)","test_object_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm","methodology_zh":"气候试验箱暴露参数 – 温度 范围：自 -60 °C 至 +100 °C","reference_en":"NO-06-A107:2005 cl. 4.2, cl. 4.3, cl. 4.5.3, cl. 4.5.4, cl. 5.6, cl. 5.7, cl. 5.8, cl. 5.91) NO-06-A107:2021 cl. 4.2, cl. 4.3, cl. 4.5.3, cl. 4.5.4, cl. 5.6, cl. 5.7, cl. 5.8, cl. 5.91)","reference_de":"NO-06-A107:2005 Abschn. 4.2, Abschn. 4.3, Abschn. 4.5.3, Abschn. 4.5.4, Abschn. 5.6, Abschn. 5.7, Abschn. 5.8, Abschn. 5.91) NO-06-A107:2021 Abschn. 4.2, Abschn. 4.3, Abschn. 4.5.3, Abschn. 4.5.4, Abschn. 5.6, Abschn. 5.7, Abschn. 5.8, Abschn. 5.91)","reference_zh":"NO-06-A107:2005 第4.2条, 第4.3条, 第4.5.3条, 第4.5.4条, 第5.6条, 第5.7条, 第5.8条, 第5.91条) NO-06-A107:2021 第4.2条, 第4.3条, 第4.5.3条, 第4.5.4条, 第5.6条, 第5.7条, 第5.8条, 第5.91条)","methodology_cs":"Parametr namáhání v klimatické komoře – Teplota Rozsah: od -60 °C do +100 °C","reference_cs":"NO-06-A107:2005 čl. 4.2, čl. 4.3, čl. 4.5.3, čl. 4.5.4, čl. 5.6, čl. 5.7, čl. 5.8, čl. 5.91) NO-06-A107:2021 čl. 4.2, čl. 4.3, čl. 4.5.3, čl. 4.5.4, čl. 5.6, čl. 5.7, čl. 5.8, čl. 5.91)","search_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm Parametr namáhání v klimatické komoře – Teplota Rozsah: od -60 °C do +100 °C NO-06-A107:2005 čl. 4.2, čl. 4.3, čl. 4.5.3, čl. 4.5.4, čl. 5.6, čl. 5.7, čl. 5.8, čl. 5.91) NO-06-A107:2021 čl. 4.2, čl. 4.3, čl. 4.5.3, čl. 4.5.4, čl. 5.6, čl. 5.7, čl. 5.8, čl. 5.91)","test_object_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm"},{"_id":"6a5a55f79af9f73f382521c1","lab_id":"69ad52a3de79e566650fb135","country":"PL","accr_number":"AB 133","accr_body":"PCA","test_object":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm","test_object_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm","methodology":"Parametr narażenia w komorze klimatycznej – Wilgotność Zakres: od 10 %RH do 95 %RH","methodology_en":"Exposure parameter in the climatic chamber – Humidity Range: from 10 %RH to 95 %RH","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametr narażenia w komorze klimatycznej – Wilgotność Zakres: od 10 %RH do 95 %RH","reference":"NO-06-A107:2005 p. 4.4, p. 4.10, p. 5.10, p. 5.12 NO-06-A107:2021 p. 4.4, p. 4.10, p. 5.10, p. 5.12","norm_bases":["NO-06-A107:2005 p. 4.4, p. 4.10, p. 5.10, p. 5.12 NO-06-A107:2021 p. 4.4, p. 4.10, p. 5.10, p. 5.12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko do celów narażeń klimatycznych dla urządzeń technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narażenia w komorze klimatycznej – Wilgotność Zakres: od 10 %RH do 95 %RH NO-06-A107:2005 p. 4.4, p. 4.10, p. 5.10, p. 5.12 NO-06-A107:2021 p. 4.4, p. 4.10, p. 5.10, p. 5.12 Srodowisko do celow narazen klimatycznych dla urzadzen technicznych o wymiarach maksymalnych (900x900x900) mm Parametr narazenia w komorze klimatycznej – Wilgotnosc Zakres: od 10 %RH do 95 %RH NO-06-A107:2005 p. 4.4, p. 4.10, p. 5.10, p. 5.12 NO-06-A107:2021 p. 4.4, p. 4.10, p. 5.10, p. 5.12","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment for climatic exposure purposes for technical equipment with maximum dimensions (900x900x900) mm Exposure parameter in the climatic chamber – Humidity Range: from 10 %RH to 95 %RH NO-06-A107:2005 cl. 4.4, cl. 4.10, cl. 5.10, cl. 5.12 NO-06-A107:2021 cl. 4.4, cl. 4.10, cl. 5.10, cl. 5.12","search_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境 气候试验箱暴露参数 – 湿度 范围：自 10 %RH 至 95 %RH NO-06-A107:2005 第4.4条, 第4.10条, 第5.10条, 第5.12条 NO-06-A107:2021 第4.4条, 第4.10条, 第5.10条, 第5.12条","test_object_zh":"最大尺寸 (900x900x900) mm 的技术装置气候环境试验用环境","methodology_de":"Beanspruchungsparameter in der Klimakammer – Feuchte Bereich: von 10 %RH bis 95 %RH","search_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm Beanspruchungsparameter in der Klimakammer – Feuchte Bereich: von 10 %RH bis 95 %RH NO-06-A107:2005 Abschn. 4.4, Abschn. 4.10, Abschn. 5.10, Abschn. 5.12 NO-06-A107:2021 Abschn. 4.4, Abschn. 4.10, Abschn. 5.10, Abschn. 5.12","test_object_de":"Umgebung für klimatische Beanspruchungen technischer Geräte mit maximalen Abmessungen (900x900x900) mm","methodology_zh":"气候试验箱暴露参数 – 湿度 范围：自 10 %RH 至 95 %RH","reference_en":"NO-06-A107:2005 cl. 4.4, cl. 4.10, cl. 5.10, cl. 5.12 NO-06-A107:2021 cl. 4.4, cl. 4.10, cl. 5.10, cl. 5.12","reference_de":"NO-06-A107:2005 Abschn. 4.4, Abschn. 4.10, Abschn. 5.10, Abschn. 5.12 NO-06-A107:2021 Abschn. 4.4, Abschn. 4.10, Abschn. 5.10, Abschn. 5.12","reference_zh":"NO-06-A107:2005 第4.4条, 第4.10条, 第5.10条, 第5.12条 NO-06-A107:2021 第4.4条, 第4.10条, 第5.10条, 第5.12条","methodology_cs":"Parametr namáhání v klimatické komoře – Vlhkost Rozsah: od 10 %RH do 95 %RH","reference_cs":"NO-06-A107:2005 čl. 4.4, čl. 4.10, čl. 5.10, čl. 5.12 NO-06-A107:2021 čl. 4.4, čl. 4.10, čl. 5.10, čl. 5.12","search_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm Parametr namáhání v klimatické komoře – Vlhkost Rozsah: od 10 %RH do 95 %RH NO-06-A107:2005 čl. 4.4, čl. 4.10, čl. 5.10, čl. 5.12 NO-06-A107:2021 čl. 4.4, čl. 4.10, čl. 5.10, čl. 5.12","test_object_cs":"Prostředí pro účely klimatického namáhání technických zařízení o maximálních rozměrech (900x900x900) mm"}],"has_pdf":true}