{"lab":{"_id":"69ad52a3de79e566650fb6c6","accr_number":"AB 1320","country":"PL","accr_body":"PCA","address":"LABORATORIUM ANALIZ CHEMICZNYCH, ul. Wojska Polskiego 3, 39-300 Mielec","categories":["petro","environment"],"city":"Mielec","imported_at":"2026-03-08T10:42:43.265Z","methods_count":16,"name":"ELEKTROCIEPŁOWNIA MIELEC Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1320.pdf"],"scope_summary":"","search_text":"elektrociepłownia mielec sp. z o.o. laboratorium analiz chemicznych, ul. wojska polskiego 3, 39-300 mielec petro other materials pharma","status":"active","updated_at":"2026-03-08T14:50:29.976Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:29.976Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201320,podmiot.html","parse_date":"2026-07-17T16:19:03.663Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, odpadów","en":"Chemical tests of solid fuels, waste"},{"codes":"N/10; N/32","pl":"Badania właściwości fizycznych paliw stałych, odpadów","en":"Tests of physical properties of solid fuels, waste"}],"issue":{"no":"14","date":"14.11.2025"},"map_coord":[50.316789,21.444709],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":13,"environment":3},"category_scores":{"petro":10.56,"environment":0.56},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f3825218c","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (1,0 – 40,0) % Metoda wagowa","methodology_en":"Free moisture content Range: (1,0 – 40,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (1,0 – 40,0) % Metoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej Zakres: (1,0 – 40,0) % Metoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej Zakres: (1,0 – 40,0) % Metoda wagowa PN-80/G-04511","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Free moisture content Range: (1,0 – 40,0) % Gravimetric method PN-80/G-04511","search_zh":"固体燃料：烟煤 PN-80/G-04511","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f3825218d","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 10,0) % Metoda wagowa","methodology_en":"Moisture content in air-dry coal Range: (0,5 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 10,0) % Metoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 10,0) % Metoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrzno-suchym Zakres: (0,5 – 10,0) % Metoda wagowa PN-80/G-04511","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in air-dry coal Range: (0,5 – 10,0) % Gravimetric method PN-80/G-04511","search_zh":"固体燃料：烟煤 PN-80/G-04511","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f3825218e","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,2 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa PN-80/G-04511","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,2 – 10,0) % Gravimetric method PN-80/G-04511","search_zh":"固体燃料：烟煤 分析样品中的水分含量 范围：(0,2 – 10,0) % 重量法 PN-80/G-04511","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析样品中的水分含量 范围：(0,2 – 10,0) % 重量法"},{"_id":"6a5a55f79af9f73f3825218f","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-80/G-04511","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55f79af9f73f38252190","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (1,0 – 45,0) % Metoda wagowa","methodology_en":"Ash content Range: (1,0 – 45,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,0 – 45,0) % Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (1,0 – 45,0) % Metoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (1,0 – 45,0) % Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (1,0 – 45,0) % Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252191","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych Zakres: (10,00 – 40,00) % Metoda wagowa","methodology_en":"Volatile matter content Range: (10,00 – 40,00) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych Zakres: (10,00 – 40,00) % Metoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych Zakres: (10,00 – 40,00) % Metoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych Zakres: (10,00 – 40,00) % Metoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Volatile matter content Range: (10,00 – 40,00) % Gravimetric method PN-G-04516:1998","search_zh":"固体燃料：烟煤 PN-G-04516:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252192","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania Zakres: (10000 – 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (10000 – 35000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (10000 – 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513 PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513 PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania Zakres: (10000 – 35000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-81/G-04513 PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania Zakres: (10000 – 35000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-81/G-04513 PN-ISO 1928:2020-05","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Gross calorific value Range: (10000 – 35000) kJ/kg Calorimetric method Net calorific value (calculated) PN-81/G-04513 PN-ISO 1928:2020-05","search_zh":"固体燃料：烟煤 PN-81/G-04513 PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252193","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulfur content Range: (0,10 – 2,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,10 – 2,50) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulfur content Range: (0,10 – 2,50) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252194","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego Zakres: (30,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (30,0 – 90,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (30,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego Zakres: (30,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego Zakres: (30,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total carbon content Range: (30,0 – 90,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252195","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (1,0 – 40,0) % Metoda wagowa","methodology_en":"First-stage (free) moisture content Range: (1,0 – 40,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (1,0 – 40,0) % Metoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (1,0 – 40,0) % Metoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej) Zakres: (1,0 – 40,0) % Metoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal First-stage (free) moisture content Range: (1,0 – 40,0) % Gravimetric method PN-ISO 589:2006","search_zh":"固体燃料：烟煤 PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252196","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa","methodology_en":"Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa","reference":"PN-ISO 589:2006 metoda A1","norm_bases":["PN-ISO 589:2006 metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoc pozostala w probce) Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 10,0) % Gravimetric method PN-ISO 589:2006 metoda A1","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 metoda A1","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f79af9f73f38252197","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,2 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,2 – 10,0) % Metoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,2 – 10,0) % Gravimetric method PN-ISO 11722:2009","search_zh":"固体燃料：烟煤 分析样品中的水分含量 范围：(0,2 – 10,0) % 重量法 PN-ISO 11722:2009","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析样品中的水分含量 范围：(0,2 – 10,0) % 重量法"},{"_id":"6a5a55f79af9f73f38252198","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 metoda A1","norm_bases":["PN-ISO 589:2006 metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 metoda A1","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 metoda A1","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55f79af9f73f38252199","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02","test_object_en":"Waste o) code: 10 01 01, 10 01 02","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,10 – 3,00) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,10 – 3,00) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,10 – 3,00) % Metoda wagowa","reference":"PB/03 z dnia 11.09.2025 r.","norm_bases":["PB/03 z dnia 11.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 10 01 01, 10 01 02 Zawartość wilgoci w próbce analitycznej Zakres: (0,10 – 3,00) % Metoda wagowa PB/03 z dnia 11.09.2025 r. Odpady o) kod: 10 01 01, 10 01 02 Zawartosc wilgoci w probce analitycznej Zakres: (0,10 – 3,00) % Metoda wagowa PB/03 z dnia 11.09.2025 r.","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste o) code: 10 01 01, 10 01 02 Moisture content in the analytical sample Range: (0,10 – 3,00) % Gravimetric method PB/03 z dnia 11.09.2025 r.","search_zh":"废物 o) 代码：10 01 01、10 01 02 PB/03 z dnia 11.09.2025 r.","test_object_zh":"废物 o) 代码：10 01 01、10 01 02"},{"_id":"6a5a55f79af9f73f3825219a","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02","test_object_en":"Waste o) code: 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego Zakres: (1,0 – 45,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (1,0 – 45,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (1,0 – 45,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PB/03 z dnia 11.09.2025 r.","norm_bases":["PB/03 z dnia 11.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 10 01 01, 10 01 02 Zawartość węgla całkowitego Zakres: (1,0 – 45,0) % Metoda wysokotemperaturowego spalania z detekcją IR PB/03 z dnia 11.09.2025 r. Odpady o) kod: 10 01 01, 10 01 02 Zawartosc wegla calkowitego Zakres: (1,0 – 45,0) % Metoda wysokotemperaturowego spalania z detekcja IR PB/03 z dnia 11.09.2025 r.","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste o) code: 10 01 01, 10 01 02 Total carbon content Range: (1,0 – 45,0) % High-temperature combustion method with IR detection PB/03 z dnia 11.09.2025 r.","search_zh":"废物 o) 代码：10 01 01、10 01 02 PB/03 z dnia 11.09.2025 r.","test_object_zh":"废物 o) 代码：10 01 01、10 01 02"},{"_id":"6a5a55f79af9f73f3825219b","lab_id":"69ad52a3de79e566650fb6c6","country":"PL","accr_number":"AB 1320","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02","test_object_en":"Waste o) code: 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego Zakres: (1,0 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (1,0 – 60,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (1,0 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 10 01 01, 10 01 02 Zawartość węgla całkowitego Zakres: (1,0 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady o) kod: 10 01 01, 10 01 02 Zawartosc wegla calkowitego Zakres: (1,0 – 60,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste o) code: 10 01 01, 10 01 02 Total carbon content Range: (1,0 – 60,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"废物 o) 代码：10 01 01、10 01 02 PN-G-04571:1998","test_object_zh":"废物 o) 代码：10 01 01、10 01 02"}],"has_pdf":true}