{"lab":{"_id":"69ad52a3de79e566650fb6a0","accr_number":"AB 1293","country":"PL","accr_body":"PCA","address":"ul. Cypriana Kamila Norwida 25, 50-375 Wrocław, CENTRUM ANALIZ JAKOŚCI ŚRODOWISKA, pl. Grunwaldzki 24a, 50-363 Wrocław","categories":["water","environment","materials"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"UNIWERSYTET PRZYRODNICZY WE WROCŁAWIU","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1293.pdf"],"scope_summary":"","search_text":"uniwersytet przyrodniczy we wrocławiu ul. cypriana kamila norwida 25, 50-375 wrocław, centrum analiz jakości środowiska, pl. grunwaldzki 24a, 50-363 wrocław water pharma electronics other materials environment","status":"active","updated_at":"2026-03-08T14:50:28.538Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:59:29.381Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201293,podmiot.html","parse_date":"2026-08-13T07:59:29.381Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/1; C/28; C/30; C/31; C/32","pl":"Badania chemiczne materiału roślinnego wody, ścieków, gleb, osadów ściekowych","en":"Chemical tests of plant material, water, sewage, soil, sediments"},{"codes":"N/28; N/30; N/31","pl":"Badania właściwości fizycznych wody, ścieków, gleb","en":"Tests of physical properties of water, sewage, soil"}],"issue":{"no":"17","date":"29.06.2026"},"map_coord":[51.111313,17.063942],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/69e773bac3491bb264aa4880b90b3afe/AB%201293.pdf","has_zh":true,"has_en":true,"category_counts":{"water":9,"environment":4,"materials":3},"category_scores":{"water":5.06,"environment":1,"materials":0.56}},"methods":[{"_id":"6a7d79610636ba417e41a984","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a985","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 3000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a986","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752","norm_bases":["PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752 Woda, Scieki Stezenie azotu amonowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 3,00) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 3,00) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PBM-01 Wydanie 3 z dnia 10.05.2022 Na podstawie testu Merck 1.14752","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a987","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(25 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (25 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (25 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (25 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(25 – 1500) mg/l O2"}],"search_zh":"水、污水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(25 – 1500) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a988","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"Fluorki","range":"(0,10 – 5,0) mg/l"},{"name":"Chlorki","range":"(0,50 – 50) mg/l"},{"name":"Azotany","range":"(0,50 – 50) mg/l"},{"name":"Azotyny","range":"(0,10 – 1,0) mg/l"},{"name":"Siarczany","range":"(5,0 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nFluorki (0,10 – 5,0) mg/l\nChlorki (0,50 – 50) mg/l\nAzotany (0,50 – 50) mg/l\nAzotyny (0,10 – 1,0) mg/l\nSiarczany (5,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie anionów:\nZakres:\nFluorki (0,10 – 5,0) mg/l\nChlorki (0,50 – 50) mg/l\nAzotany (0,50 – 50) mg/l\nAzotyny (0,10 – 1,0) mg/l\nSiarczany (5,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda, Scieki Stezenie anionow:\nZakres:\nFluorki (0,10 – 5,0) mg/l\nChlorki (0,50 – 50) mg/l\nAzotany (0,50 – 50) mg/l\nAzotyny (0,10 – 1,0) mg/l\nSiarczany (5,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"阴离子浓度：","parameters_zh":[{"name":"氟化物","range":"(0,10 – 5,0) mg/l"},{"name":"氯化物","range":"(0,50 – 50) mg/l"},{"name":"硝酸盐","range":"(0,50 – 50) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 1,0) mg/l"},{"name":"硫酸盐","range":"(5,0 – 50) mg/l"}],"search_zh":"水、污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硝酸盐 亚硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","methodology_en":"Anion concentrations:","parameters_en":[{"name":"Fluorides","range":"(0,10 – 5,0) mg/l"},{"name":"Chlorides","range":"(0,50 – 50) mg/l"},{"name":"Nitrates","range":"(0,50 – 50) mg/l"},{"name":"Nitrites","range":"(0,10 – 1,0) mg/l"},{"name":"Sulfates","range":"(5,0 – 50) mg/l"}],"search_en":"Water, Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Nitrates Nitrites Sulfates PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a989","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków:","parameters":[{"name":"Nikiel","range":"(0,020 – 100) mg/l"},{"name":"Chrom","range":"(0,050 – 100) mg/l"},{"name":"Kadm","range":"(0,005 – 100) mg/l"},{"name":"Ołów","range":"(0,020 – 100) mg/l"},{"name":"Miedź","range":"(0,020 – 100) mg/l"},{"name":"Cynk","range":"(0,050 – 100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków:\nZakres:\nNikiel (0,020 – 100) mg/l\nChrom (0,050 – 100) mg/l\nKadm (0,005 – 100) mg/l\nOłów (0,020 – 100) mg/l\nMiedź (0,020 – 100) mg/l\nCynk (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków:\nZakres:\nNikiel (0,020 – 100) mg/l\nChrom (0,050 – 100) mg/l\nKadm (0,005 – 100) mg/l\nOłów (0,020 – 100) mg/l\nMiedź (0,020 – 100) mg/l\nCynk (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow:\nZakres:\nNikiel (0,020 – 100) mg/l\nChrom (0,050 – 100) mg/l\nKadm (0,005 – 100) mg/l\nOlow (0,020 – 100) mg/l\nMiedz (0,020 – 100) mg/l\nCynk (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素浓度：","parameters_zh":[{"name":"镍","range":"(0,020 – 100) mg/l"},{"name":"铬","range":"(0,050 – 100) mg/l"},{"name":"镉","range":"(0,005 – 100) mg/l"},{"name":"铅","range":"(0,020 – 100) mg/l"},{"name":"铜","range":"(0,020 – 100) mg/l"},{"name":"锌","range":"(0,050 – 100) mg/l"}],"search_zh":"水、污水 元素浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 镍 铬 镉 铅 铜 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水","methodology_en":"Element concentrations:","parameters_en":[{"name":"Nickel","range":"(0,020 – 100) mg/l"},{"name":"Chromium","range":"(0,050 – 100) mg/l"},{"name":"Cadmium","range":"(0,005 – 100) mg/l"},{"name":"Lead","range":"(0,020 – 100) mg/l"},{"name":"Copper","range":"(0,020 – 100) mg/l"},{"name":"Zinc","range":"(0,050 – 100) mg/l"}],"search_en":"Water, Wastewater Element concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) Nickel Chromium Cadmium Lead Copper Zinc PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a98a","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,001 – 10) mg/l"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","techniques":["Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,001 – 10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","reference":"PBW-03 Wydanie 5 z dnia 10.05.2022","norm_bases":["PBW-03 Wydanie 5 z dnia 10.05.2022"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,001 – 10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji PBW-03 Wydanie 5 z dnia 10.05.2022 Woda, Scieki Stezenie rteci\nZakres (0,001 – 10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z technika amalgamacji PBW-03 Wydanie 5 z dnia 10.05.2022","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 10) mg/l"}],"search_zh":"水、污水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PBW-03 Wydanie 5 z dnia 10.05.2022","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、污水","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,001 – 10) mg/l"}],"search_en":"Water, Wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PBW-03 Wydanie 5 z dnia 10.05.2022","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, Wastewater"},{"_id":"6a7d79610636ba417e41a98b","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(40 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (40 – 99,5) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres (40 – 99,5) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa\nZakres (40 – 99,5) %\nMetoda wagowa PN-ISO 11465:1999","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(40 – 99,5) %"}],"search_zh":"土壤 干物质 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(40 – 99,5) %"}],"search_en":"Soil Dry matter Gravimetric method Range PN-ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil"},{"_id":"6a7d79610636ba417e41a98c","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Gleba","methodology":"pH w H2O","parameters":[{"name":"Zakres","range":"3,0 – 10,0"},{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna pH w KCl; Metoda potencjometryczna","techniques":["Metoda potencjometryczna pH w KCl","Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH w KCl; Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH w KCl; Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH w KCl; Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"},{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"土壤 水中 pH 值 KCl 中 pH 电位法；电位法 范围 范围 PN-EN ISO 10390:2022-09","technique_zh":"KCl 中 pH 电位法；电位法","test_object_zh":"土壤","methodology_en":"pH in H2O","parameters_en":[{"name":"Range","range":"3,0 – 10,0"},{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Soil pH in H2O Potentiometric method pH in KCl; Potentiometric method Range Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method pH in KCl; Potentiometric method","test_object_en":"Soil"},{"_id":"6a7d79610636ba417e41a98d","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Materiał roślinny","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,001 – 10) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,001 – 10) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PBW-04 Wydanie 5 z dnia 10.05.2022","norm_bases":["PBW-04 Wydanie 5 z dnia 10.05.2022"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe, Materiał roślinny Zawartość rtęci\nZakres (0,001 – 10) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PBW-04 Wydanie 5 z dnia 10.05.2022 Gleba, Osady sciekowe, Material roslinny Zawartosc rteci\nZakres (0,001 – 10) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PBW-04 Wydanie 5 z dnia 10.05.2022","categories":["water","materials","environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,001 – 10) mg/kg"}],"search_zh":"土壤、污泥、植物材料 汞含量 原子吸收光谱法（汞齐化技术） 范围 PBW-04 Wydanie 5 z dnia 10.05.2022","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、污泥、植物材料","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,001 – 10) mg/kg"}],"search_en":"Soil, Sewage sludge, Plant material Mercury content Atomic absorption spectrometry with amalgamation technique Range PBW-04 Wydanie 5 z dnia 10.05.2022","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil, Sewage sludge, Plant material"},{"_id":"6a7d79610636ba417e41a98e","lab_id":"69ad52a3de79e566650fb6a0","country":"PL","accr_number":"AB 1293","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Cynk","range":"(20,0 – 1000) mg/kg"},{"name":"Kadm","range":"(1,00 – 500) mg/kg"},{"name":"Ołów","range":"(10,0 – 500) mg/kg"},{"name":"Miedź","range":"(10,0 – 500) mg/kg"},{"name":"Nikiel","range":"(10,0 – 500) mg/kg"},{"name":"Chrom","range":"(1,00 – 500) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nZakres:\nCynk (20,0 – 1000) mg/kg\nKadm (1,00 – 500) mg/kg\nOłów (10,0 – 500) mg/kg\nMiedź (10,0 – 500) mg/kg\nNikiel (10,0 – 500) mg/kg\nChrom (1,00 – 500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PBW-20 Wydanie 6 z dnia 31.03.2022","norm_bases":["PBW-20 Wydanie 6 z dnia 31.03.2022"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość pierwiastków:\nZakres:\nCynk (20,0 – 1000) mg/kg\nKadm (1,00 – 500) mg/kg\nOłów (10,0 – 500) mg/kg\nMiedź (10,0 – 500) mg/kg\nNikiel (10,0 – 500) mg/kg\nChrom (1,00 – 500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PBW-20 Wydanie 6 z dnia 31.03.2022 Gleba, Osady sciekowe Zawartosc pierwiastkow:\nZakres:\nCynk (20,0 – 1000) mg/kg\nKadm (1,00 – 500) mg/kg\nOlow (10,0 – 500) mg/kg\nMiedz (10,0 – 500) mg/kg\nNikiel (10,0 – 500) mg/kg\nChrom (1,00 – 500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PBW-20 Wydanie 6 z dnia 31.03.2022","categories":["water","materials","environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素含量：","parameters_zh":[{"name":"锌","range":"(20,0 – 1000) mg/kg"},{"name":"镉","range":"(1,00 – 500) mg/kg"},{"name":"铅","range":"(10,0 – 500) mg/kg"},{"name":"铜","range":"(10,0 – 500) mg/kg"},{"name":"镍","range":"(10,0 – 500) mg/kg"},{"name":"铬","range":"(1,00 – 500) mg/kg"}],"search_zh":"土壤、污泥 元素含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 锌 镉 铅 铜 镍 铬 PBW-20 Wydanie 6 z dnia 31.03.2022","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤、污泥","methodology_en":"Element content:","parameters_en":[{"name":"Zinc","range":"(20,0 – 1000) mg/kg"},{"name":"Cadmium","range":"(1,00 – 500) mg/kg"},{"name":"Lead","range":"(10,0 – 500) mg/kg"},{"name":"Copper","range":"(10,0 – 500) mg/kg"},{"name":"Nickel","range":"(10,0 – 500) mg/kg"},{"name":"Chromium","range":"(1,00 – 500) mg/kg"}],"search_en":"Soil, Sewage sludge Element content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Zinc Cadmium Lead Copper Nickel Chromium PBW-20 Wydanie 6 z dnia 31.03.2022","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil, Sewage sludge"}],"has_pdf":true}