{"lab":{"_id":"69ad52a3de79e566650fb69e","accr_number":"AB 1291","country":"PL","accr_body":"PCA","address":"OCHRONY ŚRODOWISKA „KALMAT”, ul. Kruczkowskiego 4, 21-500 Biała Podlaska","categories":["environment"],"city":"Biała Podlaska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"Kaliszuk Marian, PRACOWNIA USŁUGOWA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1291.pdf"],"scope_summary":"","search_text":"kaliszuk marian, pracownia usługowa ochrony środowiska „kalmat”, ul. kruczkowskiego 4, 21-500 biała podlaska environment pharma other","status":"active","updated_at":"2026-03-08T14:50:28.477Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:28.477Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201291,podmiot.html","parse_date":"2026-07-17T16:19:02.999Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/36","pl":"Badania chemiczne gazów odlotowych","en":"Chemical tests of waste gases"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska - gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - waste gases"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"12","date":"28.09.2023"},"map_coord":[52.039443,23.097808],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":5,"environment":3},"category_scores":{"other":3.13,"environment":1.13},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f38251f8d","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量 皮托管法"},{"_id":"6a5a55f79af9f73f38251f8e","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f79af9f73f38251f8f","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 − 100) g/m³ Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 − 100) g/m³ Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 − 100) g/m³ Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 − 100) g/m³ Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 − 100) g/m³ Metoda grawimetryczna","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 − 100) g/m³ Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f38251f90","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55f79af9f73f38251f91","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie O , CO , SO , NO, NO CO 2 2 2 2, Zakres: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 Metoda NDIR O (0,01 − 21) % 2 Metoda elektrochemiczna","methodology_en":"O , CO , SO , NO, NO CO concentration 2 2 2 2, Range: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 NDIR method O (0,01 − 21) % 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie O , CO , SO , NO, NO CO 2 2 2 2, Zakres: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 Metoda NDIR O (0,01 − 21) % 2 Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie O , CO , SO , NO, NO CO 2 2 2 2, Zakres: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 Metoda NDIR O (0,01 − 21) % 2 Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie O , CO , SO , NO, NO CO 2 2 2 2, Zakres: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 Metoda NDIR O (0,01 − 21) % 2 Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases O , CO , SO , NO, NO CO concentration 2 2 2 2, Range: CO (8 – 1400) mg/m³ NO (10 – 400) mg/m³ NO (8,0 – 45) mg/m³ 2 SO (15 − 1400) mg/m³ 2 CO (0,04 − 18) % 2 NDIR method O (0,01 − 21) % 2 Electrochemical method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f38251f92","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO , SO , NO i NO , NO (NO 2 2 2 x i NO w przeliczeniu na NO ),CO 2 2 (z obliczeń)","methodology_en":"Emission of CO , SO , NO and NO , NO (NO 2 2 2 x and NO calculated as NO ),CO 2 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO , SO , NO i NO , NO (NO 2 2 2 x i NO w przeliczeniu na NO ),CO 2 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO , SO , NO i NO , NO (NO 2 2 2 x i NO w przeliczeniu na NO ),CO 2 2 (z obliczeń) Gazy odlotowe Emisja CO , SO , NO i NO , NO (NO 2 2 2 x i NO w przeliczeniu na NO ),CO 2 2 (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of CO , SO , NO and NO , NO (NO 2 2 2 x and NO calculated as NO ),CO 2 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f38251f93","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem worków tedlarowych","methodology_en":"Sampling for determination of the concentrations of organic compounds Aspiration method using Tedlar bags","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem worków tedlarowych","reference":"Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r.","norm_bases":["Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem worków tedlarowych Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r. Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych Metoda aspiracyjna z zastosowaniem workow tedlarowych Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r.","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using Tedlar bags Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r.","search_zh":"废气 Procedura Badawcza PR-12-01 wydanie 7 z dnia 09.08.2012 r.","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f38251f94","lab_id":"69ad52a3de79e566650fb69e","country":"PL","accr_number":"AB 1291","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04030-7:1994","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"}],"has_pdf":true}