{"lab":{"_id":"69ad52a3de79e566650fb690","accr_number":"AB 1283","country":"PL","accr_body":"PCA","address":"Al. Powstańców Warszawy 12, 35-029 Rzeszów, UCZELNIANE LABORATORIUM BADAŃ MATERIAŁÓW, DLA PRZEMYSŁU LOTNICZEGO, ul. Żwirki i Wigury 4","categories":["materials"],"city":"Rzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"POLITECHNIKA RZESZOWSKA im. IGNACEGO ŁUKASIEWICZA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1283.pdf"],"scope_summary":"","search_text":"politechnika rzeszowska im. ignacego łukasiewicza al. powstańców warszawy 12, 35-029 rzeszów, uczelniane laboratorium badań materiałów, dla przemysłu lotniczego, ul. żwirki i wigury 4 materials other electronics pharma","status":"active","updated_at":"2026-03-08T14:50:27.917Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:59:09.262Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201283,podmiot.html","parse_date":"2026-08-13T07:59:09.262Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"− J/8","pl":"− Badania mechaniczne, badania metalograficzne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests, metallographic tests of construction products and materials"},{"codes":"− N/8, N/12","pl":"− Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych i ceramiki","en":"Tests of physical properties of construction products and materials and ceramics"}],"issue":{"no":"15","date":"28.07.2026"},"map_coord":[50.019041,21.989102],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Badań Właściwości Mechanicznych","address":"ul. Żwirki i Wigury 4, 35-036 Rzeszów","city":"Rzeszów","postal":"35-036"},{"name":"Pracownia Badań Mikroskopowych","address":"ul. Żwirki i Wigury 4, 35-036 Rzeszów","city":"Rzeszów","postal":"35-036"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/d3c42b624d6959462f88c4fe26a6e3ff/AB%201283.pdf","has_en":true,"category_counts":{"materials":12},"category_scores":{"materials":12},"has_zh":true,"lab_locations_zh":[{"name":"力学性能检验室","address":"ul. Żwirki i Wigury 4, 35-036 Rzeszów","city":"Rzeszów","postal":"35-036"},{"name":"显微镜检验室","address":"ul. Żwirki i Wigury 4, 35-036 Rzeszów","city":"Rzeszów","postal":"35-036"}]},"methods":[{"_id":"6a7d794d0636ba417e41a85b","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Właściwości wytrzymałościowe","parameters":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Statyczna próba rozciągania w temperaturze pokojowej:"},{"name":"siła","range":"(0 - 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości wytrzymałościowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna próba rozciągania w temperaturze pokojowej:\nsiła (0 - 100) kN","reference":"PN-EN ISO 6892-1:2010 metoda B | PN-EN ISO 6892-1:2020-05 metoda B | ASTM E8/E8M-25","norm_bases":["PN-EN ISO 6892-1:2010 metoda B","PN-EN ISO 6892-1:2020-05 metoda B","ASTM E8/E8M-25"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Właściwości wytrzymałościowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna próba rozciągania w temperaturze pokojowej:\nsiła (0 - 100) kN PN-EN ISO 6892-1:2010 metoda B | PN-EN ISO 6892-1:2020-05 metoda B | ASTM E8/E8M-25 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Wlasciwosci wytrzymalosciowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna proba rozciagania w temperaturze pokojowej:\nsila (0 - 100) kN PN-EN ISO 6892-1:2010 metoda B | PN-EN ISO 6892-1:2020-05 metoda B | ASTM E8/E8M-25","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Strength properties","parameters_en":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Static tensile test at room temperature:"},{"name":"force","range":"(0 - 100) kN"}],"search_en":"Metals and metal alloys in cast or wrought form Strength properties Mechanical Properties Testing Laboratory Rm, Re, Rp0.2, A, Z Static tensile test at room temperature: force PN-EN ISO 6892-1:2010 metoda B | PN-EN ISO 6892-1:2020-05 metoda B | ASTM E8/E8M-25","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Statyczna próba rozciągania w temperaturze pokojowej:"},{"name":"力","range":"(0 - 100) kN"}],"search_zh":"铸态或塑性加工态的金属与合金 强度性能 力学性能检验室 力 PN-EN ISO 6892-1:2010 metoda B | PN-EN ISO 6892-1:2020-05 metoda B | ASTM E8/E8M-25","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室","methodology_zh":"强度性能"},{"_id":"6a7d794d0636ba417e41a85c","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Właściwości wytrzymałościowe","parameters":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Statyczna próba rozciągania w podwyższonej temperaturze"},{"name":"siła","range":"(0 - 50) kN,"},{"name":"Temperatura max.1000 oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości wytrzymałościowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna próba rozciągania w podwyższonej temperaturze\nsiła (0 - 50) kN,\nTemperatura max.1000 oC","reference":"PN-EN ISO 6892-2:2018-08 | ASTM E21-20","norm_bases":["PN-EN ISO 6892-2:2018-08","ASTM E21-20"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Właściwości wytrzymałościowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna próba rozciągania w podwyższonej temperaturze\nsiła (0 - 50) kN,\nTemperatura max.1000 oC PN-EN ISO 6892-2:2018-08 | ASTM E21-20 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Wlasciwosci wytrzymalosciowe\nZakres:\nRm, Re, Rp0.2, A, Z\nStatyczna proba rozciagania w podwyzszonej temperaturze\nsila (0 - 50) kN,\nTemperatura max.1000 oC PN-EN ISO 6892-2:2018-08 | ASTM E21-20","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Strength properties","parameters_en":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Static tensile test at elevated temperature"},{"name":"force","range":"(0 - 50) kN,"},{"name":"Temperature max.1000 oC"}],"search_en":"Metals and metal alloys in cast or wrought form Strength properties Mechanical Properties Testing Laboratory Rm, Re, Rp0.2, A, Z Static tensile test at elevated temperature force Temperature max.1000 oC PN-EN ISO 6892-2:2018-08 | ASTM E21-20","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"Rm, Re, Rp0.2, A, Z"},{"name":"Statyczna próba rozciągania w podwyższonej temperaturze"},{"name":"力","range":"(0 - 50) kN,"},{"name":"Temperatura max.1000 oC"}],"search_zh":"铸态或塑性加工态的金属与合金 强度性能 力学性能检验室 力 PN-EN ISO 6892-2:2018-08 | ASTM E21-20","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室","methodology_zh":"强度性能"},{"_id":"6a7d794d0636ba417e41a85d","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Właściwości wytrzymałościowe tu, tfx, Au, Af, Zu.","parameters":[{"name":"Próba pełzania przy jednoosiowym rozciąganiu"},{"name":"siła","range":"(0 - 30) kN,"},{"name":"Temperatura","range":"(150 - 1000) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości wytrzymałościowe tu, tfx, Au, Af, Zu.\nZakres:\nPróba pełzania przy jednoosiowym rozciąganiu\nsiła (0 - 30) kN,\nTemperatura (150 - 1000) oC","reference":"PN-EN ISO 204:2024-02 | ASTM E139-24","norm_bases":["PN-EN ISO 204:2024-02","ASTM E139-24"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Właściwości wytrzymałościowe tu, tfx, Au, Af, Zu.\nZakres:\nPróba pełzania przy jednoosiowym rozciąganiu\nsiła (0 - 30) kN,\nTemperatura (150 - 1000) oC PN-EN ISO 204:2024-02 | ASTM E139-24 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Wlasciwosci wytrzymalosciowe tu, tfx, Au, Af, Zu.\nZakres:\nProba pelzania przy jednoosiowym rozciaganiu\nsila (0 - 30) kN,\nTemperatura (150 - 1000) oC PN-EN ISO 204:2024-02 | ASTM E139-24","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Strength properties tu, tfx, Au, Af, Zu.","parameters_en":[{"name":"Uniaxial tensile creep test"},{"name":"force","range":"(0 - 30) kN,"},{"name":"Temperature","range":"(150 - 1000) oC"}],"search_en":"Metals and metal alloys in cast or wrought form Strength properties tu, tfx, Au, Af, Zu. Mechanical Properties Testing Laboratory Uniaxial tensile creep test force Temperature PN-EN ISO 204:2024-02 | ASTM E139-24","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"Próba pełzania przy jednoosiowym rozciąganiu"},{"name":"力","range":"(0 - 30) kN,"},{"name":"温度","range":"(150 - 1000) oC"}],"search_zh":"铸态或塑性加工态的金属与合金 力学性能检验室 力 温度 PN-EN ISO 204:2024-02 | ASTM E139-24","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室"},{"_id":"6a7d794d0636ba417e41a85e","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Twardość sposobem Brinella HBW 5/250; HBW 2,5/62,5","parameters":[{"name":"Zakres","range":"kulka Ø 5 mm; 2,5 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Twardość sposobem Brinella HBW 5/250; HBW 2,5/62,5\nZakres kulka Ø 5 mm; 2,5 mm","reference":"PN-EN ISO 6506-1:2014-12 | ASTM E10-23","norm_bases":["PN-EN ISO 6506-1:2014-12","ASTM E10-23"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardość sposobem Brinella HBW 5/250; HBW 2,5/62,5\nZakres kulka Ø 5 mm; 2,5 mm PN-EN ISO 6506-1:2014-12 | ASTM E10-23 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardosc sposobem Brinella HBW 5/250; HBW 2,5/62,5\nZakres kulka Ø 5 mm; 2,5 mm PN-EN ISO 6506-1:2014-12 | ASTM E10-23","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Hardness by the Brinell method HBW 5/250; HBW 2,5/62,5","parameters_en":[{"name":"Range","range":"kulka Ø 5 mm; 2,5 mm"}],"search_en":"Metals and metal alloys in cast or wrought form Hardness by the Brinell method HBW 5/250; HBW 2,5/62,5 Mechanical Properties Testing Laboratory Range PN-EN ISO 6506-1:2014-12 | ASTM E10-23","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"kulka Ø 5 mm; 2,5 mm"}],"search_zh":"铸态或塑性加工态的金属与合金 力学性能检验室 范围 PN-EN ISO 6506-1:2014-12 | ASTM E10-23","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室"},{"_id":"6a7d794d0636ba417e41a85f","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Twardość sposobem Rockwella","parameters":[{"name":"Zakres","range":"skala B, C"}],"technique":"Metoda Rockwella","techniques":["Metoda Rockwella"],"computed":[],"activity":"Twardość sposobem Rockwella\nZakres skala B, C\nMetoda Rockwella","reference":"PN-EN ISO 6508-1:2024-06 | ASTM E18-25","norm_bases":["PN-EN ISO 6508-1:2024-06","ASTM E18-25"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardość sposobem Rockwella\nZakres skala B, C\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 | ASTM E18-25 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardosc sposobem Rockwella\nZakres skala B, C\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 | ASTM E18-25","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Hardness by the Rockwell method","parameters_en":[{"name":"Range","range":"skala B, C"}],"search_en":"Metals and metal alloys in cast or wrought form Hardness by the Rockwell method Rockwell method Mechanical Properties Testing Laboratory Range PN-EN ISO 6508-1:2024-06 | ASTM E18-25","technique_en":"Rockwell method","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"skala B, C"}],"search_zh":"铸态或塑性加工态的金属与合金 洛氏法 力学性能检验室 范围 PN-EN ISO 6508-1:2024-06 | ASTM E18-25","technique_zh":"洛氏法","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室"},{"_id":"6a7d794d0636ba417e41a860","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Twardość sposobem Vickersa","parameters":[{"name":"Zakres","range":"HV 10"}],"technique":null,"techniques":[],"computed":[],"activity":"Twardość sposobem Vickersa\nZakres HV 10","reference":"PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 6507-1:2024-04"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardość sposobem Vickersa\nZakres HV 10 PN-EN ISO 6507-1:2024-04 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Twardosc sposobem Vickersa\nZakres HV 10 PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Hardness by the Vickers method","parameters_en":[{"name":"Range","range":"HV 10"}],"search_en":"Metals and metal alloys in cast or wrought form Hardness by the Vickers method Mechanical Properties Testing Laboratory Range PN-EN ISO 6507-1:2024-04","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"HV 10"}],"search_zh":"铸态或塑性加工态的金属与合金 力学性能检验室 范围 PN-EN ISO 6507-1:2024-04","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室"},{"_id":"6a7d794d0636ba417e41a861","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Praca łamania","parameters":[{"name":"Zakres","range":"KV2; KU2"},{"name":"Początkowa energia młota","range":"300 J"},{"name":"Temperatura badania","range":"23±5oC"},{"name":"Próba udarności metodą Charpy'ego"}],"technique":null,"techniques":[],"computed":[],"activity":"Praca łamania\nZakres:\nZakres KV2; KU2\nPoczątkowa energia młota 300 J\nTemperatura badania 23±5oC\nPróba udarności metodą Charpy'ego","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Praca łamania\nZakres:\nZakres KV2; KU2\nPoczątkowa energia młota 300 J\nTemperatura badania 23±5oC\nPróba udarności metodą Charpy'ego PN-EN ISO 148-1:2017-02 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Praca lamania\nZakres:\nZakres KV2; KU2\nPoczatkowa energia mlota 300 J\nTemperatura badania 23±5oC\nProba udarnosci metoda Charpy'ego PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Impact energy","parameters_en":[{"name":"Range","range":"KV2; KU2"},{"name":"Initial hammer energy","range":"300 J"},{"name":"Test temperature","range":"23±5oC"},{"name":"Charpy impact test"}],"search_en":"Metals and metal alloys in cast or wrought form Impact energy Mechanical Properties Testing Laboratory Range Initial hammer energy Test temperature Charpy impact test PN-EN ISO 148-1:2017-02","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"KV2; KU2"},{"name":"锤的初始能量","range":"300 J"},{"name":"试验温度","range":"23±5oC"},{"name":"Próba udarności metodą Charpy'ego"}],"search_zh":"铸态或塑性加工态的金属与合金 断裂功 力学性能检验室 范围 锤的初始能量 试验温度 PN-EN ISO 148-1:2017-02","methodology_zh":"断裂功","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室"},{"_id":"6a7d794d0636ba417e41a862","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Udarność","parameters":[{"name":"Zakres","range":"KCU2; KCU"},{"name":"początkowa energia młota","range":"300 J"},{"name":"Temperatura badania","range":"23±5oC"},{"name":"Próba udarności metodą Charpy'ego"}],"technique":null,"techniques":[],"computed":[],"activity":"Udarność\nZakres:\nZakres KCU2; KCU\npoczątkowa energia młota 300 J\nTemperatura badania 23±5oC\nPróba udarności metodą Charpy'ego","reference":"PN-EN 10045-1:1994","norm_bases":["PN-EN 10045-1:1994"],"lab_section":"Pracownia Badań Właściwości Mechanicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Udarność\nZakres:\nZakres KCU2; KCU\npoczątkowa energia młota 300 J\nTemperatura badania 23±5oC\nPróba udarności metodą Charpy'ego PN-EN 10045-1:1994 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Udarnosc\nZakres:\nZakres KCU2; KCU\npoczatkowa energia mlota 300 J\nTemperatura badania 23±5oC\nProba udarnosci metoda Charpy'ego PN-EN 10045-1:1994","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Mechanical Properties Testing Laboratory","methodology_en":"Impact strength","parameters_en":[{"name":"Range","range":"KCU2; KCU"},{"name":"initial hammer energy","range":"300 J"},{"name":"Test temperature","range":"23±5oC"},{"name":"Charpy impact test"}],"search_en":"Metals and metal alloys in cast or wrought form Impact strength Mechanical Properties Testing Laboratory Range initial hammer energy Test temperature Charpy impact test PN-EN 10045-1:1994","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"KCU2; KCU"},{"name":"początkowa energia młota","range":"300 J"},{"name":"试验温度","range":"23±5oC"},{"name":"Próba udarności metodą Charpy'ego"}],"search_zh":"铸态或塑性加工态的金属与合金 冲击韧性 力学性能检验室 范围 试验温度 PN-EN 10045-1:1994","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"力学性能检验室","methodology_zh":"冲击韧性"},{"_id":"6a7d794d0636ba417e41a863","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale, stopy metali, materiały ceramiczne","methodology":"Skład chemiczny w mikroobszarze – analiza jakościowa","parameters":[],"technique":"Metoda elektronowej mikroskopii skaningowej z systemem EDS (SEM-EDS)","techniques":["Metoda elektronowej mikroskopii skaningowej z systemem EDS (SEM-EDS)"],"computed":[],"activity":"Skład chemiczny w mikroobszarze – analiza jakościowa\nMetoda elektronowej mikroskopii skaningowej z systemem EDS (SEM-EDS)","reference":"ASTM E 1508-12","norm_bases":["ASTM E 1508-12"],"lab_section":"Pracownia Badań Mikroskopowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale, stopy metali, materiały ceramiczne Skład chemiczny w mikroobszarze – analiza jakościowa\nMetoda elektronowej mikroskopii skaningowej z systemem EDS (SEM-EDS) ASTM E 1508-12 Metale, stopy metali, materialy ceramiczne Sklad chemiczny w mikroobszarze – analiza jakosciowa\nMetoda elektronowej mikroskopii skaningowej z systemem EDS (SEM-EDS) ASTM E 1508-12","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microscopic Examination Laboratory","methodology_en":"Chemical composition in a microarea – qualitative analysis","search_en":"Metals, metal alloys, ceramic materials Chemical composition in a microarea – qualitative analysis Scanning electron microscopy method with an EDS system (SEM-EDS) Microscopic Examination Laboratory ASTM E 1508-12","technique_en":"Scanning electron microscopy method with an EDS system (SEM-EDS)","test_object_en":"Metals, metal alloys, ceramic materials","lab_section_zh":"显微镜检验室","search_zh":"显微镜检验室 ASTM E 1508-12"},{"_id":"6a7d794d0636ba417e41a864","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale, stopy metali, materiały ceramiczne","methodology":"Mikrostruktura i morfologia powierzchni","parameters":[],"technique":"Metoda skaningowej mikroskopii elektronowej","techniques":["Metoda skaningowej mikroskopii elektronowej"],"computed":[],"activity":"Mikrostruktura i morfologia powierzchni\nMetoda skaningowej mikroskopii elektronowej","reference":"PB/P3/03 wyd. z 15.06.2022 r.","norm_bases":["PB/P3/03 wyd. z 15.06.2022 r."],"lab_section":"Pracownia Badań Mikroskopowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale, stopy metali, materiały ceramiczne Mikrostruktura i morfologia powierzchni\nMetoda skaningowej mikroskopii elektronowej PB/P3/03 wyd. z 15.06.2022 r. Metale, stopy metali, materialy ceramiczne Mikrostruktura i morfologia powierzchni\nMetoda skaningowej mikroskopii elektronowej PB/P3/03 wyd. z 15.06.2022 r.","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microscopic Examination Laboratory","methodology_en":"Microstructure and surface morphology","search_en":"Metals, metal alloys, ceramic materials Microstructure and surface morphology Scanning electron microscopy method Microscopic Examination Laboratory PB/P3/03 wyd. z 15.06.2022 r.","technique_en":"Scanning electron microscopy method","test_object_en":"Metals, metal alloys, ceramic materials","search_zh":"扫描电子显微镜法 显微镜检验室 PB/P3/03 wyd. z 15.06.2022 r.","technique_zh":"扫描电子显微镜法","lab_section_zh":"显微镜检验室"},{"_id":"6a7d794d0636ba417e41a865","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Mikrotwardość sposobem Vickersa","parameters":[{"name":"Zakres","range":"HV 0,1; HV 0,2; HV 0,3;"},{"name":"HV 0,5; HV 1,0"}],"technique":null,"techniques":[],"computed":[],"activity":"Mikrotwardość sposobem Vickersa\nZakres:\nZakres HV 0,1; HV 0,2; HV 0,3;\nHV 0,5; HV 1,0","reference":"ASTM E384-22","norm_bases":["ASTM E384-22"],"lab_section":"Pracownia Badań Mikroskopowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Mikrotwardość sposobem Vickersa\nZakres:\nZakres HV 0,1; HV 0,2; HV 0,3;\nHV 0,5; HV 1,0 ASTM E384-22 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Mikrotwardosc sposobem Vickersa\nZakres:\nZakres HV 0,1; HV 0,2; HV 0,3;\nHV 0,5; HV 1,0 ASTM E384-22","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microscopic Examination Laboratory","methodology_en":"Microhardness by the Vickers method","parameters_en":[{"name":"Range","range":"HV 0,1; HV 0,2; HV 0,3;"},{"name":"HV 0,5; HV 1,0"}],"search_en":"Metals and metal alloys in cast or wrought form Microhardness by the Vickers method Microscopic Examination Laboratory Range HV 0,5; HV 1,0 ASTM E384-22","test_object_en":"Metals and metal alloys in cast or wrought form","parameters_zh":[{"name":"范围","range":"HV 0,1; HV 0,2; HV 0,3;"},{"name":"HV 0,5; HV 1,0"}],"search_zh":"铸态或塑性加工态的金属与合金 显微镜检验室 范围 ASTM E384-22","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"显微镜检验室"},{"_id":"6a7d794d0636ba417e41a866","lab_id":"69ad52a3de79e566650fb690","country":"PL","accr_number":"AB 1283","accr_body":"PCA","test_object":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie","methodology":"Wielkość ziarna, Mikroskopia świetlna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielkość ziarna, Mikroskopia świetlna","reference":"ASTM E112-25","norm_bases":["ASTM E112-25"],"lab_section":"Pracownia Badań Mikroskopowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Metale i stopy metali w postaci lanej lub przerobionej plastycznie Wielkość ziarna, Mikroskopia świetlna ASTM E112-25 Metale i stopy metali w postaci lanej lub przerobionej plastycznie Wielkosc ziarna, Mikroskopia swietlna ASTM E112-25","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microscopic Examination Laboratory","methodology_en":"Grain size, Light microscopy","search_en":"Metals and metal alloys in cast or wrought form Grain size, Light microscopy Microscopic Examination Laboratory ASTM E112-25","test_object_en":"Metals and metal alloys in cast or wrought form","search_zh":"铸态或塑性加工态的金属与合金 显微镜检验室 ASTM E112-25","test_object_zh":"铸态或塑性加工态的金属与合金","lab_section_zh":"显微镜检验室"}],"has_pdf":true}