{"lab":{"_id":"69ad52a3de79e566650fb686","accr_number":"AB 1274","country":"PL","accr_body":"PCA","address":"W CZŁUCHOWIE, ul. Jana III Sobieskiego 4, 77 – 300 Człuchów","categories":["water","microbiology","food"],"city":"Człuchów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1274.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w człuchowie, ul. jana iii sobieskiego 4, 77 – 300 człuchów water pharma electronics other food microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:26.869Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:26.869Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201274,podmiot.html","parse_date":"2026-07-17T16:19:01.457Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/29/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests and sampling of drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia","en":"Tests of physical properties of water, drinking water"},{"codes":"N/29/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of drinking water"},{"codes":"K/1; K/55; K/3; K/28; K/29; K/22","pl":"Badania mikrobiologiczne produktów rolnych, pasz dla zwierząt, obiektów i materiałów biologicznych, wody, wody do spożycia przez ludzi, żywność","en":"Microbiological tests of agricultural products, animal feedstuffs, biological items and materials for testing, water, drinking water, food"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"15","date":"23.05.2025"},"map_coord":[53.661931,17.353847],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":21,"microbiology":9,"food":5},"category_scores":{"water":12.6,"microbiology":2.31,"food":0.71},"has_zh":true},"methods":[{"_id":"6a5a55f59af9f73f38251be9","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (147 – 1600) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (147 – 1600) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (147 – 1600) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (147 – 1600) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (147 – 1600) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Electrical conductivity Range: (147 – 1600) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水 PN-EN 27888:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bea","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres:(0,15 – 8,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range:(0,15 – 8,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres:(0,15 – 8,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego Zakres:(0,15 – 8,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego Zakres:(0,15 – 8,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ammonium ion concentration Range:(0,15 – 8,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251beb","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu Zakres: (0,02 – 1,0) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,02 – 1,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,02 – 1,0) mg/l Metoda spektrofotometryczna","reference":"PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor","norm_bases":["PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu Zakres: (0,02 – 1,0) mg/l Metoda spektrofotometryczna PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor Woda, woda do spozycia przez ludzi Stezenie manganu Zakres: (0,02 – 1,0) mg/l Metoda spektrofotometryczna PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Manganese concentration Range: (0,02 – 1,0) mg/l Spectrophotometric method PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor","search_zh":"水、生活饮用水 PB-6/WO wydanie 4, data wydania 04.02.2021 na podstawie testu odczynnikowego Nanocolor","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bec","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 40) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012 pkt 7+ Ap1:2015","norm_bases":["PN-EN ISO 7887:2012 pkt 7+ Ap1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 pkt 7+ Ap1:2015 Woda, woda do spozycia przez ludzi Barwa Zakres: (5 – 40) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 pkt 7+ Ap1:2015","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (5 – 40) mg/l Pt Visual method PN-EN ISO 7887:2012 pkt 7+ Ap1:2015","search_zh":"水、生活饮用水 PN-EN ISO 7887:2012 pkt 7+ Ap1:2015","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bed","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水（含游泳池水）、生活饮用水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f59af9f73f38251bee","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 50) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Metnosc Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Turbidity Range: (0,10 – 50) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水（含游泳池水）、生活饮用水 浊度 范围：(0,10 – 50) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"浊度 范围：(0,10 – 50) NTU 散射法"},{"_id":"6a5a55f59af9f73f38251bef","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016","norm_bases":["PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Total iron concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016","search_zh":"水（含游泳池水）、生活饮用水 PN-ISO 6332:2001 pkt 7.1.1 + Ap1:2016","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf0","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie azotanów Zakres: (1,0 – 60,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (1,0 – 60,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (1,0 – 60,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie azotanów Zakres: (1,0 – 60,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie azotanow Zakres: (1,0 – 60,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Nitrate concentration Range: (1,0 – 60,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水（含游泳池水）、生活饮用水 PN-82/C-04576.08","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf1","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (1,0 – 10,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Indeks nadmanganianowy Zakres: (1,0 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Permanganate index Range: (1,0 – 10,0) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水（含游泳池水）、生活饮用水 PN-EN ISO 8467:2001","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf2","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru ogólnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna","methodology_en":"Total chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna","reference":"PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167","norm_bases":["PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru ogólnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru ogolnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Total chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167","search_zh":"水（含游泳池水）、生活饮用水 PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8167","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf3","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-12/WO wydanie 2, data wydania 16.09.2020","norm_bases":["PB-12/WO wydanie 2, data wydania 16.09.2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru związanego (z obliczeń) PB-12/WO wydanie 2, data wydania 16.09.2020 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru zwiazanego (z obliczen) PB-12/WO wydanie 2, data wydania 16.09.2020","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Combined chlorine concentration (calculated) PB-12/WO wydanie 2, data wydania 16.09.2020","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水）、生活饮用水 化合氯浓度（计算值） PB-12/WO wydanie 2, data wydania 16.09.2020","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf4","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru wolnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna","methodology_en":"Free chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna","reference":"PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021","norm_bases":["PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru wolnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru wolnego Zakres: (0,1 – 2,0) mg/l Metoda kolorymetryczna PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Free chlorine concentration Range: (0,1 – 2,0) mg/l Colorimetric method PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021","search_zh":"水（含游泳池水）、生活饮用水 PB-12/WO wydanie 2, data wydania 16.09.2020 na podstawie metodyki Hach 8021","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf5","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 z wył. pkt. 6.5","norm_bases":["PN-ISO 5667-5:2017-10 z wył. pkt. 6.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wył. pkt. 6.5 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wyl. pkt. 6.5","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 z wył. pkt. 6.5","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 z wył. pkt. 6.5","test_object_zh":"生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf6","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Count of Escherichia coli and coliform bacteria Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Count of Escherichia coli and coliform bacteria Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","search_zh":"水、生活饮用水 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf7","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55f59af9f73f38251bf8","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 22°C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C Metoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total count of microorganisms at 22°C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bf9","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 36°C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C Metoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C Metoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total count of microorganisms at 36°C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bfa","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda, woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"水、生活饮用水","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55f59af9f73f38251bfb","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba Legionella Zakres: od 1 jtk / 100 ml/ 1000 ml Metoda filtracji membranowej Matryca B, Procedura 7 (pożywka C - GVPC)","methodology_en":"Legionella count Range: from 1 CFU / 100 ml/ 1000 ml Membrane filtration method Matrix B, Procedure 7 (medium C - GVPC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Legionella Zakres: od 1 jtk / 100 ml/ 1000 ml Metoda filtracji membranowej Matryca B, Procedura 7 (pożywka C - GVPC)","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba Legionella Zakres: od 1 jtk / 100 ml/ 1000 ml Metoda filtracji membranowej Matryca B, Procedura 7 (pożywka C - GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba Legionella Zakres: od 1 jtk / 100 ml/ 1000 ml Metoda filtracji membranowej Matryca B, Procedura 7 (pozywka C - GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water (including swimming pool water), water intended for human consumption Legionella count Range: from 1 CFU / 100 ml/ 1000 ml Membrane filtration method Matrix B, Procedure 7 (medium C - GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 PN-EN ISO 11731:2017-08 + Ap1:2019-12","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5a55f59af9f73f38251bfc","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Pobieranie próbek wody do badań mikrobiologicznych","methodology_en":"Water sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Pobieranie próbek wody do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda Woda do spozycia przez ludzi Pobieranie probek wody do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Water sampling for microbiological testing PN-EN ISO 19458:2007","search_zh":"水 生活饮用水 用于微生物检验的水样采集 PN-EN ISO 19458:2007","test_object_zh":"水 生活饮用水","methodology_zh":"用于微生物检验的水样采集"},{"_id":"6a5a55f59af9f73f38251bfd","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Woda powierzchniowa, woda z kąpielisk i miejsc wykorzystywanych do kąpieli","test_object_en":"Surface water, bathing water and water from sites used for bathing","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL)","methodology_en":"Most probable number of Escherichia coli Miniaturised method (MPN)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa, woda z kąpielisk i miejsc wykorzystywanych do kąpieli Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002 Woda powierzchniowa, woda z kapielisk i miejsc wykorzystywanych do kapieli Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water, bathing water and water from sites used for bathing Most probable number of Escherichia coli Miniaturised method (MPN) PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌最可能数 微量法（MPN）","search_zh":"大肠埃希氏菌最可能数 微量法（MPN） PN-EN ISO 9308-3:2002"},{"_id":"6a5a55f59af9f73f38251bfe","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie","test_object_en":"Meat and meat products Milk and milk products Cereal products Delicatessen products Fruit and vegetable preserves Confectionery and bakery products","methodology":"Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","norm_bases":["PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09 Mieso i przetwory miesne Mleko i przetwory mleczne Przetwory zbozowe Wyroby garmazeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Obecnosc Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","categories":["food","microbiology"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Meat and meat products Milk and milk products Cereal products Delicatessen products Fruit and vegetable preserves Confectionery and bakery products Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","methodology_zh":"沙门氏菌属的检出 培养法（附生化与血清学确证）","search_zh":"沙门氏菌属的检出 培养法（附生化与血清学确证） PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09"},{"_id":"6a5a55f59af9f73f38251bff","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie","test_object_en":"Meat and meat products Milk and milk products Cereal products Delicatessen products Fruit and vegetable preserves Confectionery and bakery products","methodology":"Obecność Listeria monocytogenes Metoda hodowlana z potwierdzeniem biochemicznym","methodology_en":"Presence of Listeria monocytogenes Culture method with biochemical confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność Listeria monocytogenes Metoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Obecność Listeria monocytogenes Metoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Mieso i przetwory miesne Mleko i przetwory mleczne Przetwory zbozowe Wyroby garmazeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Obecnosc Listeria monocytogenes Metoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Meat and meat products Milk and milk products Cereal products Delicatessen products Fruit and vegetable preserves Confectionery and bakery products Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","methodology_zh":"单核细胞增生李斯特氏菌的检出 培养法（附生化确证）","search_zh":"单核细胞增生李斯特氏菌的检出 培养法（附生化确证） PN-EN ISO 11290-1:2017-07"},{"_id":"6a5a55f59af9f73f38251c00","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Mięso i przetwory mięsne Mleko i przetwory mleczne Środki specjalnego przeznaczenia żywieniowego Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie","test_object_en":"Meat and meat products Milk and dairy products Foodstuffs for particular nutritional uses Delicatessen products Fruit and vegetable products Confectionery and pastry products","methodology":"Liczba Listeria monocytogenes Metoda płytkowa (posiew powierzchniowy)","methodology_en":"Listeria monocytogenes count Plate method (surface plating)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Listeria monocytogenes Metoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso i przetwory mięsne Mleko i przetwory mleczne Środki specjalnego przeznaczenia żywieniowego Wyroby garmażeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Liczba Listeria monocytogenes Metoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Mieso i przetwory miesne Mleko i przetwory mleczne Srodki specjalnego przeznaczenia zywieniowego Wyroby garmazeryjne Przetwory owocowe i warzywne Wyroby cukiernicze i ciastkarskie Liczba Listeria monocytogenes Metoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Meat and meat products Milk and dairy products Foodstuffs for particular nutritional uses Delicatessen products Fruit and vegetable products Confectionery and pastry products Listeria monocytogenes count Plate method (surface plating) PN-EN ISO 11290-2:2017-07","methodology_zh":"单核细胞增生李斯特氏菌数 平板法（表面涂布）","search_zh":"单核细胞增生李斯特氏菌数 平板法（表面涂布） PN-EN ISO 11290-2:2017-07"},{"_id":"6a5a55f59af9f73f38251c01","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne","test_object_en":"Meat and meat products Milk and dairy products Cereal products Delicatessen products Fruit and vegetable products","methodology":"Liczba Enterobacteriaceae Metoda płytkowa (posiew wgłębny) w temp. 37 °C","methodology_en":"Enterobacteriaceae count Plate method (pour plate) at 37 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Enterobacteriaceae Metoda płytkowa (posiew wgłębny) w temp. 37 °C","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso i przetwory mięsne Mleko i przetwory mleczne Przetwory zbożowe Wyroby garmażeryjne Przetwory owocowe i warzywne Liczba Enterobacteriaceae Metoda płytkowa (posiew wgłębny) w temp. 37 °C PN-EN ISO 21528-2:2017-08 Mieso i przetwory miesne Mleko i przetwory mleczne Przetwory zbozowe Wyroby garmazeryjne Przetwory owocowe i warzywne Liczba Enterobacteriaceae Metoda plytkowa (posiew wglebny) w temp. 37 °C PN-EN ISO 21528-2:2017-08","categories":["food"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Meat and meat products Milk and dairy products Cereal products Delicatessen products Fruit and vegetable products Enterobacteriaceae count Plate method (pour plate) at 37 °C PN-EN ISO 21528-2:2017-08"},{"_id":"6a5a55f59af9f73f38251c02","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Pasze dla zwierząt","test_object_en":"Animal feed","methodology":"Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","norm_bases":["PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze dla zwierząt Obecność Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09 Pasze dla zwierzat Obecnosc Salmonella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","categories":["microbiology","food"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Animal feed Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","search_zh":"动物饲料 沙门氏菌属的检出 培养法（附生化与血清学确证） PN-EN ISO 6579-1:2017-04 PN-EN ISO 6579-1:2017-04/A1:2020- 09","test_object_zh":"动物饲料","methodology_zh":"沙门氏菌属的检出 培养法（附生化与血清学确证）"},{"_id":"6a5a55f59af9f73f38251c03","lab_id":"69ad52a3de79e566650fb686","country":"PL","accr_number":"AB 1274","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","test_object_en":"Faeces, rectal swab","methodology":"Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence and identification of Salmonella and Shigella rods Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-1/ML, wyd. 4, data wydania 25.04.2019r.","norm_bases":["PB-1/ML, wyd. 4, data wydania 25.04.2019r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, wymaz z odbytu Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-1/ML, wyd. 4, data wydania 25.04.2019r. Kal, wymaz z odbytu Obecnosc i identyfikacja paleczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-1/ML, wyd. 4, data wydania 25.04.2019r.","categories":["microbiology"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Faeces, rectal swab Presence and identification of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB-1/ML, wyd. 4, data wydania 25.04.2019r.","search_zh":"粪便、肛拭子 PB-1/ML, wyd. 4, data wydania 25.04.2019r.","test_object_zh":"粪便、肛拭子"}],"has_pdf":true}