{"lab":{"_id":"69ad52a3de79e566650fb67c","accr_number":"AB 1267","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, Niecew 68, 33-322 Korzenna","categories":["construction","environment","water","materials","petro"],"city":"Korzenna","imported_at":"2026-03-08T10:42:43.265Z","methods_count":52,"name":"MO-BRUK SPÓŁKA AKCYJNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1267.pdf"],"scope_summary":"","search_text":"mo-bruk spółka akcyjna laboratorium badawcze, niecew 68, 33-322 korzenna petro other materials environment construction water","status":"active","updated_at":"2026-03-08T14:50:26.346Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:26.346Z","email_confidence":"high","email_mx":true,"email_source":"https://mobruk.pl/kontakt/","parse_date":"2026-07-17T16:19:01.051Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek ścieków, odpadów","en":"Chemical tests and sampling of sewage, waste"},{"codes":"C/5/P","pl":"Badania chemiczne i pobieranie próbek materiałów budowlanych","en":"Chemical tests and sampling building materials"},{"codes":"C/28/P","pl":"Badania chemiczne i pobieranie próbek wody","en":"Chemical tests and sampling of water"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków, odpadów","en":"Tests of physical properties and sampling of sewage, waste"},{"codes":"N/10; N/28","pl":"Badania właściwości fizycznych wody, paliw stałych","en":"Tests of physical properties of water, solid fuels"},{"codes":"N/5/P","pl":"Badanie właściwości fizycznych i pobieranie próbek materiałów budowlanych","en":"Tests of physical properties and sampling building materials"}],"issue":{"no":"16","date":"04.09.2025"},"map_coord":[49.683211,20.841842],"map_geo":"nominatim-city","has_en":true,"category_counts":{"construction":34,"environment":25,"water":25,"materials":22,"petro":10},"category_scores":{"construction":9.97,"environment":5.39,"water":5.39,"materials":4.17,"petro":0.86},"has_zh":true},"methods":[{"_id":"6a5a55f59af9f73f38251ad3","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa","methodology_en":"Total moisture content Range: (2,00 – 90,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa","reference":"PB-04 wydanie 7 z dnia 01.06.2022 r.","norm_bases":["PB-04 wydanie 7 z dnia 01.06.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa PB-04 wydanie 7 z dnia 01.06.2022 r. Paliwa stale: - paliwa wtorne Zawartosc wilgoci calkowitej Zakres: (2,00 – 90,0) % Metoda wagowa PB-04 wydanie 7 z dnia 01.06.2022 r.","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Total moisture content Range: (2,00 – 90,0) % Gravimetric method PB-04 wydanie 7 z dnia 01.06.2022 r.","search_zh":"固体燃料：－ 再生燃料 PB-04 wydanie 7 z dnia 01.06.2022 r.","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ad4","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (1,0 – 5,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: - paliwa wtorne Zawartosc wilgoci w probce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Moisture content in the analytical sample Range: (1,0 – 5,0) % Gravimetric method PN-EN ISO 21660-3:2021-08","search_zh":"固体燃料：－ 再生燃料 PN-EN ISO 21660-3:2021-08","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ad5","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Heat of combustion Range: (6000 – 45000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Paliwa stale: - paliwa wtorne Cieplo spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Heat of combustion Range: (6000 – 45000) kJ/kg Calorimetric method Net calorific value (calculated) PN-EN ISO 21654:2021-12","search_zh":"固体燃料：－ 再生燃料 PN-EN ISO 21654:2021-12","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ad6","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa","methodology_en":"Ash content Range: (0,2 – 90,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: - paliwa wtorne Zawartosc popiolu Zakres: (0,2 – 90,0) % Metoda wagowa PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Ash content Range: (0,2 – 90,0) % Gravimetric method PN-EN ISO 21656:2021-08","search_zh":"固体燃料：－ 再生燃料 PN-EN ISO 21656:2021-08","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ad7","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Hydrogen content Range: (1,00 – 10,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: - paliwa wtorne Zawartosc wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Hydrogen content Range: (1,00 – 10,0) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：－ 再生燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ad8","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: - paliwa wtorne Zawartosc wegla calkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method PN-EN ISO 21663:2021-06","search_zh":"固体燃料：－ 再生燃料 全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：－ 再生燃料","methodology_zh":"全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法"},{"_id":"6a5a55f59af9f73f38251ad9","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulfur content Range: (0,08 – 10,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: - paliwa wtorne Zawartosc siarki calkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Total sulfur content Range: (0,08 – 10,0) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"固体燃料：－ 再生燃料 PN-EN ISO 21663:2021-06","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251ada","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna","methodology_en":"Chlorine content Range: (0,02 – 50,0) % Coulometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna","reference":"PB-02 wydanie 8 z dnia 23.08.2022 r.","norm_bases":["PB-02 wydanie 8 z dnia 23.08.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna PB-02 wydanie 8 z dnia 23.08.2022 r. Paliwa stale: - paliwa wtorne Zawartosc chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna PB-02 wydanie 8 z dnia 23.08.2022 r.","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Chlorine content Range: (0,02 – 50,0) % Coulometric method PB-02 wydanie 8 z dnia 23.08.2022 r.","search_zh":"固体燃料：－ 再生燃料 PB-02 wydanie 8 z dnia 23.08.2022 r.","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251adb","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal content Range: - lead (1,00 – 100) mg/kg - cadmium (1,00 – 100) mg/kg - nickel (1,00 – 100) mg/kg - copper (1,00 – 100) mg/kg - zinc (1,00 – 100) mg/kg - chromium (1,00 – 100) mg/kg - arsenic (0,500 – 200) mg/kg - antimony (0,500 – 200) mg/kg Inductively coupled plasma atomic emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009 Paliwa stale: - paliwa wtorne Zawartosc metali Zakres: - olow (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedz (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","categories":["materials","petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Metal content Range: - lead (1,00 – 100) mg/kg - cadmium (1,00 – 100) mg/kg - nickel (1,00 – 100) mg/kg - copper (1,00 – 100) mg/kg - zinc (1,00 – 100) mg/kg - chromium (1,00 – 100) mg/kg - arsenic (0,500 – 200) mg/kg - antimony (0,500 – 200) mg/kg Inductively coupled plasma atomic emission spectrometry method (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","search_zh":"固体燃料：－ 再生燃料 PN-EN 13657:2006 PN-EN ISO 11885:2009","test_object_zh":"固体燃料：－ 再生燃料"},{"_id":"6a5a55f59af9f73f38251adc","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Paliwa stałe: - paliwa wtórne","test_object_en":"Solid fuels: - secondary fuels","methodology":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","methodology_en":"Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - paliwa wtórne Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01 Paliwa stale: - paliwa wtorne Strata przy prazeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - secondary fuels Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method PN-EN 15935:2022-01","search_zh":"固体燃料：－ 再生燃料 烧失量（LOI） 范围：(1,00 – 95,0) % 重量法 PN-EN 15935:2022-01","test_object_zh":"固体燃料：－ 再生燃料","methodology_zh":"烧失量（LOI） 范围：(1,00 – 95,0) % 重量法"},{"_id":"6a5a55f59af9f73f38251add","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PO-11 wydanie 2 z dnia 30.04.2024 r.","norm_bases":["PO-11 wydanie 2 z dnia 30.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Pobieranie próbek do badań chemicznych i fizycznych PO-11 wydanie 2 z dnia 30.04.2024 r. Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Pobieranie probek do badan chemicznych i fizycznych PO-11 wydanie 2 z dnia 30.04.2024 r.","categories":["environment","water","materials","construction"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Sampling for chemical and physical testing PO-11 wydanie 2 z dnia 30.04.2024 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） 化学与物理检测用样品采集 PO-11 wydanie 2 z dnia 30.04.2024 r.","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ade","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa","methodology_en":"Total moisture content Range: (2,00 – 90,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa","reference":"PB-04 wydanie 7 z dnia 01.06.2022 r.","norm_bases":["PB-04 wydanie 7 z dnia 01.06.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość wilgoci całkowitej Zakres: (2,00 – 90,0) % Metoda wagowa PB-04 wydanie 7 z dnia 01.06.2022 r. Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc wilgoci calkowitej Zakres: (2,00 – 90,0) % Metoda wagowa PB-04 wydanie 7 z dnia 01.06.2022 r.","categories":["environment","water","materials","construction"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total moisture content Range: (2,00 – 90,0) % Gravimetric method PB-04 wydanie 7 z dnia 01.06.2022 r.","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PB-04 wydanie 7 z dnia 01.06.2022 r.","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251adf","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (1,0 – 5,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc wilgoci w probce analitycznej Zakres: (1,0 – 5,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment","water","materials","construction"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Moisture content in the analytical sample Range: (1,0 – 5,0) % Gravimetric method PN-EN ISO 21660-3:2021-08","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN ISO 21660-3:2021-08","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae0","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Hydrogen content Range: (1,00 – 10,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc wodoru Zakres: (1,00 – 10,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","water","materials","construction"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Hydrogen content Range: (1,00 – 10,0) % High-temperature combustion method with IR detection PN-EN ISO 21663:2021-06","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN ISO 21663:2021-06","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae1","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulfur content Range: (0,08 – 10,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość siarki całkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcją IR Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc siarki calkowitej Zakres: (0,08 – 10,0) % Metoda wysokotemperaturowego spalania z detekcja IR","categories":["environment","water","materials","construction"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total sulfur content Range: (0,08 – 10,0) % High-temperature combustion method with IR detection","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae2","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa","methodology_en":"Ash content Range: (0,2 – 90,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa","reference":"PN-EN ISO 21656:2021-08 Metoda B","norm_bases":["PN-EN ISO 21656:2021-08 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość popiołu Zakres: (0,2 – 90,0) % Metoda wagowa PN-EN ISO 21656:2021-08 Metoda B Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc popiolu Zakres: (0,2 – 90,0) % Metoda wagowa PN-EN ISO 21656:2021-08 Metoda B","categories":["environment","materials","construction"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Ash content Range: (0,2 – 90,0) % Gravimetric method PN-EN ISO 21656:2021-08 Metoda B","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN ISO 21656:2021-08 Metoda B","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae3","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR","methodology_en":"Total inorganic carbon content Range: (0,10 – 12,0) % Phosphoric acid decarbonation method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR","reference":"PN-EN 15936:2013-02","norm_bases":["PN-EN 15936:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR PN-EN 15936:2013-02 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc ogolnego wegla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcja IR PN-EN 15936:2013-02","categories":["environment","materials","construction"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total inorganic carbon content Range: (0,10 – 12,0) % Phosphoric acid decarbonation method with IR detection PN-EN 15936:2013-02","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN 15936:2013-02","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae4","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc wegla calkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcja IR","categories":["environment","materials","construction"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） 全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）","methodology_zh":"全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法"},{"_id":"6a5a55f59af9f73f38251ae5","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość ogólnego węgla organicznego (z obliczeń)","methodology_en":"Total organic carbon content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (z obliczeń)","reference":"PN-EN 15936:2013-02","norm_bases":["PN-EN 15936:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość ogólnego węgla organicznego (z obliczeń) PN-EN 15936:2013-02 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc ogolnego wegla organicznego (z obliczen) PN-EN 15936:2013-02","categories":["environment","materials","construction"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total organic carbon content (calculated) PN-EN 15936:2013-02","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN 15936:2013-02","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae6","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna","methodology_en":"Chlorine content Range: (0,02 – 50,0) % Coulometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna","reference":"PB-02 wydanie 8 z dnia 23.08.2022 r.","norm_bases":["PB-02 wydanie 8 z dnia 23.08.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna PB-02 wydanie 8 z dnia 23.08.2022 r. Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc chloru Zakres: (0,02 – 50,0) % Metoda kulometryczna PB-02 wydanie 8 z dnia 23.08.2022 r.","categories":["environment","materials","construction"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Chlorine content Range: (0,02 – 50,0) % Coulometric method PB-02 wydanie 8 z dnia 23.08.2022 r.","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PB-02 wydanie 8 z dnia 23.08.2022 r.","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae7","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal content Range: - lead (1,00 – 100) mg/kg - cadmium (1,00 – 100) mg/kg - nickel (1,00 – 100) mg/kg - copper (1,00 – 100) mg/kg - zinc (1,00 – 100) mg/kg - chromium (1,00 – 100) mg/kg - arsenic (0,500 – 200) mg/kg - antimony (0,500 – 200) mg/kg Inductively coupled plasma atomic emission spectrometry method (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość metali Zakres: - ołów (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedź (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc metali Zakres: - olow (1,00 – 100) mg/kg - kadm (1,00 – 100) mg/kg - nikiel (1,00 – 100) mg/kg - miedz (1,00 – 100) mg/kg - cynk (1,00 – 100) mg/kg - chrom (1,00 – 100) mg/kg - arsen (0,500 – 200) mg/kg - antymon (0,500 – 200) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","categories":["materials","environment","construction"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Metal content Range: - lead (1,00 – 100) mg/kg - cadmium (1,00 – 100) mg/kg - nickel (1,00 – 100) mg/kg - copper (1,00 – 100) mg/kg - zinc (1,00 – 100) mg/kg - chromium (1,00 – 100) mg/kg - arsenic (0,500 – 200) mg/kg - antimony (0,500 – 200) mg/kg Inductively coupled plasma atomic emission spectrometry method (ICP-OES) PN-EN 13657:2006 PN-EN ISO 11885:2009","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN 13657:2006 PN-EN ISO 11885:2009","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae8","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury content Range: (0,0500 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-09 wydanie 2 z dnia 15.03.2024 r.","norm_bases":["PB-09 wydanie 2 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-09 wydanie 2 z dnia 15.03.2024 r. Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc rteci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-09 wydanie 2 z dnia 15.03.2024 r.","categories":["environment","materials","construction"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Mercury content Range: (0,0500 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique PB-09 wydanie 2 z dnia 15.03.2024 r.","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PB-09 wydanie 2 z dnia 15.03.2024 r.","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251ae9","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń)","methodology_en":"Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l - arsenic (0,050 – 20,0) mg/l - antimony (0,050 – 20,0) mg/l - selenium (0,050 – 20,0) mg/l - barium (0,050 – 20,0) mg/l - molybdenum (0,050 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) Element content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń) PN-EN 12457-4:2006 PN-EN ISO 11885:2009 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Stezenie metali Zakres: - olow (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedz (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Zawartosc pierwiastkow (z obliczen) PN-EN 12457-4:2006 PN-EN ISO 11885:2009","categories":["materials","water","environment","construction"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l - arsenic (0,050 – 20,0) mg/l - antimony (0,050 – 20,0) mg/l - selenium (0,050 – 20,0) mg/l - barium (0,050 – 20,0) mg/l - molybdenum (0,050 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) Element content (calculated) PN-EN 12457-4:2006 PN-EN ISO 11885:2009","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PN-EN ISO 11885:2009","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aea","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń)","methodology_en":"Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) Mercury content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","norm_bases":["PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r. Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Stezenie rteci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartosc rteci (z obliczen) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","categories":["water","environment","construction"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) Mercury content (calculated) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aeb","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC- CD) Zawartość anionów (z obliczeń)","methodology_en":"Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC- CD) Anion content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC- CD) Zawartość anionów (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC- CD) Zawartość anionów (z obliczeń) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Stezenie anionow Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC- CD) Zawartosc anionow (z obliczen) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","categories":["water","environment","construction"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC- CD) Anion content (calculated) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aec","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń)","methodology_en":"Chromium VI concentration Range: (0,050 – 100) mg/l Spectrophotometric method Chromium VI content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","norm_bases":["PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Stezenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartosc chromu VI (z obliczen) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","categories":["water","environment","construction"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Chromium VI concentration Range: (0,050 – 100) mg/l Spectrophotometric method Chromium VI content (calculated) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aed","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń)","methodology_en":"Dissolved organic carbon DOC concentration Range: (30,0 – 300) mg/l Spectrophotometric method DOC content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","norm_bases":["PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Stezenie rozpuszczonego wegla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartosc DOC (z obliczen) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","categories":["water","environment","construction"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Dissolved organic carbon DOC concentration Range: (30,0 – 300) mg/l Spectrophotometric method DOC content (calculated) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aee","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń)","methodology_en":"Dissolved solids TDS Range: (100 – 50 000) mg/l Gravimetric method TDS content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006 PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń) PN-EN 12457-4:2006 PN-EN 15216:2022-03 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartosc TDS (z obliczen) PN-EN 12457-4:2006 PN-EN 15216:2022-03","categories":["water","environment","construction"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) Dissolved solids TDS Range: (100 – 50 000) mg/l Gravimetric method TDS content (calculated) PN-EN 12457-4:2006 PN-EN 15216:2022-03","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） PN-EN 12457-4:2006 PN-EN 15216:2022-03","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）"},{"_id":"6a5a55f59af9f73f38251aef","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI)","test_object_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI)","methodology":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 13,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna","reference":"PN-EN 12457-4:2006 PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) pH Zakres: 2,0 – 13,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012 Odpady DAB-11: - Odpady budowlane (III) - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) pH Zakres: 2,0 – 13,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012","categories":["water","environment","construction"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI) pH Range: 2,0 – 13,0 Potentiometric method PN-EN 12457-4:2006 PN-EN ISO 10523:2012","search_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI） pH 范围：2,0 – 13,0 电位法 PN-EN 12457-4:2006 PN-EN ISO 10523:2012","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI）","methodology_zh":"pH 范围：2,0 – 13,0 电位法"},{"_id":"6a5a55f59af9f73f38251af0","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","methodology_en":"Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Strata przy prazeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01","categories":["environment","water","materials","construction"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method PN-EN 15935:2022-01","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） 烧失量（LOI） 范围：(1,00 – 95,0) % 重量法 PN-EN 15935:2022-01","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）","methodology_zh":"烧失量（LOI） 范围：(1,00 – 95,0) % 重量法"},{"_id":"6a5a55f59af9f73f38251af1","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR","methodology_en":"Total inorganic carbon content Range: (0,10 – 12,0) % Phosphoric acid decarbonation method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR","reference":"PN-EN 15936:2013-02","norm_bases":["PN-EN 15936:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość ogólnego węgla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcją IR PN-EN 15936:2013-02 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc ogolnego wegla nieorganicznego Zakres: (0,10 – 12,0) % Metoda dekarbonizacji kwasem fosforowym z detekcja IR PN-EN 15936:2013-02","categories":["environment","water","materials","construction"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total inorganic carbon content Range: (0,10 – 12,0) % Phosphoric acid decarbonation method with IR detection PN-EN 15936:2013-02","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN 15936:2013-02","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251af2","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość węgla całkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc wegla calkowitego Zakres: (0,70 – 80,0) % Metoda wysokotemperaturowego spalania z detekcja IR","categories":["environment","water","materials","construction"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total carbon content Range: (0,70 – 80,0) % High-temperature combustion with IR detection method","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） 全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）","methodology_zh":"全碳含量 范围：(0,70 – 80,0) % 高温燃烧-红外检测法"},{"_id":"6a5a55f59af9f73f38251af3","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Zawartość ogólnego węgla organicznego (z obliczeń)","methodology_en":"Total organic carbon content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (z obliczeń)","reference":"PN-EN 15936:2013-02","norm_bases":["PN-EN 15936:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Zawartość ogólnego węgla organicznego (z obliczeń) PN-EN 15936:2013-02 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Zawartosc ogolnego wegla organicznego (z obliczen) PN-EN 15936:2013-02","categories":["environment","water","materials","construction"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Total organic carbon content (calculated) PN-EN 15936:2013-02","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN 15936:2013-02","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251af4","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Heat of combustion Range: (6000 – 45000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Osady z procesów przemysłowych (VII), - Odpady z oczyszczania gazów odlotowych (X), - Żużle, popioły i pyły paleniskowe (XI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Ciepło spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Osady z procesow przemyslowych (VII), - Odpady z oczyszczania gazow odlotowych (X), - Zuzle, popioly i pyly paleniskowe (XI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Cieplo spalania Zakres: (6000 – 45000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["environment","water","materials","construction"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Sludges from industrial processes (VII), - Waste from waste gas cleaning (X), - Slags, ashes and furnace dusts (XI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Heat of combustion Range: (6000 – 45000) kJ/kg Calorimetric method Net calorific value (calculated) PN-EN ISO 21654:2021-12","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） PN-EN ISO 21654:2021-12","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 工业过程污泥（VII），－ 废气净化废物（X），－ 炉渣、灰与炉膛粉尘（XI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）"},{"_id":"6a5a55f59af9f73f38251af5","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV)","test_object_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV)","methodology":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","methodology_en":"Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI), - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), - Tworzywa sztuczne (XXV) Strata przy prażeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01 Odpady DAB-11: - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI), - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), - Tworzywa sztuczne (XXV) Strata przy prazeniu (LOI) Zakres: (1,00 – 95,0) % Metoda wagowa PN-EN 15935:2022-01","categories":["environment","materials","construction"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste DAB-11: - Construction waste (III) - Waste from waste treatment (VI), - Waste from the production and use of protective coatings, adhesives and paints (XVI), - Plastics (XXV) Loss on ignition (LOI) Range: (1,00 – 95,0) % Gravimetric method PN-EN 15935:2022-01","search_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV） 烧失量（LOI） 范围：(1,00 – 95,0) % 重量法 PN-EN 15935:2022-01","test_object_zh":"废物 DAB-11：－ 建筑废物（III） － 废物处理产生的废物（VI），－ 防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），－ 塑料（XXV）","methodology_zh":"烧失量（LOI） 范围：(1,00 – 95,0) % 重量法"},{"_id":"6a5a55f59af9f73f38251af6","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne","test_object_en":"Artificial aggregate","methodology":"Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Mercury content Range: (0,0500 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-09 wydanie 2 z dnia 15.03.2024 r.","norm_bases":["PB-09 wydanie 2 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne Zawartość rtęci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-09 wydanie 2 z dnia 15.03.2024 r. Kruszywo sztuczne Zawartosc rteci Zakres: (0,0500 – 10,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-09 wydanie 2 z dnia 15.03.2024 r.","categories":["construction"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate Mercury content Range: (0,0500 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique PB-09 wydanie 2 z dnia 15.03.2024 r."},{"_id":"6a5a55f59af9f73f38251af7","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne","test_object_en":"Artificial aggregate","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PO-11 wydanie 2 z dnia 30.04.2024 r.","norm_bases":["PO-11 wydanie 2 z dnia 30.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne Pobieranie próbek do badań chemicznych i fizycznych PO-11 wydanie 2 z dnia 30.04.2024 r. Kruszywo sztuczne Pobieranie probek do badan chemicznych i fizycznych PO-11 wydanie 2 z dnia 30.04.2024 r.","categories":["construction"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate Sampling for chemical and physical testing PO-11 wydanie 2 z dnia 30.04.2024 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PO-11 wydanie 2 z dnia 30.04.2024 r."},{"_id":"6a5a55f59af9f73f38251af8","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń)","methodology_en":"Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l - arsenic (0,050 – 20,0) mg/l - antimony (0,050 – 20,0) mg/l - selenium (0,050 – 20,0) mg/l - barium (0,050 – 20,0) mg/l - molybdenum (0,050 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) Element content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Zawartość pierwiastków (z obliczeń) PN-EN 12457-4:2006 PN-EN ISO 11885:2009 Kruszywo sztuczne (wyciag wodny) Stezenie metali Zakres: - olow (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedz (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l - arsen (0,050 – 20,0) mg/l - antymon (0,050 – 20,0) mg/l - selen (0,050 – 20,0) mg/l - bar (0,050 – 20,0) mg/l - molibden (0,050 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Zawartosc pierwiastkow (z obliczen) PN-EN 12457-4:2006 PN-EN ISO 11885:2009","categories":["materials","construction"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l - arsenic (0,050 – 20,0) mg/l - antimony (0,050 – 20,0) mg/l - selenium (0,050 – 20,0) mg/l - barium (0,050 – 20,0) mg/l - molybdenum (0,050 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) Element content (calculated) PN-EN 12457-4:2006 PN-EN ISO 11885:2009","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PN-EN ISO 11885:2009","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251af9","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń)","methodology_en":"Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) Mercury content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","norm_bases":["PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartość rtęci (z obliczeń) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r. Kruszywo sztuczne (wyciag wodny) Stezenie rteci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Zawartosc rteci (z obliczen) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","categories":["construction"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) Mercury content (calculated) PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PB-09 wydanie 2 z dnia 15.03.2024 r.","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251afa","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość anionów (z obliczeń)","methodology_en":"Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC-CD) Anion content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość anionów (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Zawartość anionów (z obliczeń) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009 Kruszywo sztuczne (wyciag wodny) Stezenie anionow Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Zawartosc anionow (z obliczen) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","categories":["construction"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC-CD) Anion content (calculated) PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PN-EN ISO 10304-1:2009","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251afb","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń)","methodology_en":"Chromium VI concentration Range: (0,050 – 100) mg/l Spectrophotometric method Chromium VI content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","norm_bases":["PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Stężenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartość chromu VI (z obliczeń) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313 Kruszywo sztuczne (wyciag wodny) Stezenie chromu VI Zakres: (0,050 – 100) mg/l Metoda spektrofotometryczna Zawartosc chromu VI (z obliczen) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","categories":["construction"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Chromium VI concentration Range: (0,050 – 100) mg/l Spectrophotometric method Chromium VI content (calculated) PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PB-07 wydanie 6 z dnia 23.08.2022 r. na podstawie testu kuwetowego LCK 313","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251afc","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń)","methodology_en":"Dissolved organic carbon DOC concentration Range: (30,0 – 300) mg/l Spectrophotometric method DOC content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń)","reference":"PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","norm_bases":["PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Stężenie rozpuszczonego węgla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartość DOC (z obliczeń) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386 Kruszywo sztuczne (wyciag wodny) Stezenie rozpuszczonego wegla organicznego DOC Zakres: (30,0 – 300) mg/l Metoda spektrofotometryczna Zawartosc DOC (z obliczen) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","categories":["construction"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Dissolved organic carbon DOC concentration Range: (30,0 – 300) mg/l Spectrophotometric method DOC content (calculated) PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PB-08 wydanie 5 z dnia 01.06.2022 r. na podstawie testu kuwetowego LCK 386","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251afd","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń)","methodology_en":"Dissolved solids TDS Range: (100 – 50 000) mg/l Gravimetric method TDS content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń)","reference":"PN-EN 12457-4:2006 PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006 PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartość TDS (z obliczeń) PN-EN 12457-4:2006 PN-EN 15216:2022-03 Kruszywo sztuczne (wyciag wodny) Substancje rozpuszczone TDS Zakres: (100 – 50 000) mg/l Metoda wagowa Zawartosc TDS (z obliczen) PN-EN 12457-4:2006 PN-EN 15216:2022-03","categories":["construction"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) Dissolved solids TDS Range: (100 – 50 000) mg/l Gravimetric method TDS content (calculated) PN-EN 12457-4:2006 PN-EN 15216:2022-03","search_zh":"人造集料（水浸出液） PN-EN 12457-4:2006 PN-EN 15216:2022-03","test_object_zh":"人造集料（水浸出液）"},{"_id":"6a5a55f59af9f73f38251afe","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Kruszywo sztuczne (wyciąg wodny)","test_object_en":"Artificial aggregate (water extract)","methodology":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 13,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 13,0 Metoda potencjometryczna","reference":"PN-EN 12457-4:2006 PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo sztuczne (wyciąg wodny) pH Zakres: 2,0 – 13,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012 Kruszywo sztuczne (wyciag wodny) pH Zakres: 2,0 – 13,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012","categories":["construction"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Artificial aggregate (water extract) pH Range: 2,0 – 13,0 Potentiometric method PN-EN 12457-4:2006 PN-EN ISO 10523:2012","search_zh":"人造集料（水浸出液） pH 范围：2,0 – 13,0 电位法 PN-EN 12457-4:2006 PN-EN ISO 10523:2012","test_object_zh":"人造集料（水浸出液）","methodology_zh":"pH 范围：2,0 – 13,0 电位法"},{"_id":"6a5a55f59af9f73f38251aff","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55f59af9f73f38251b00","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 170) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (5,0 – 170) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 170) mg/l Metoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (5,0 – 170) mg/l Metoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (5,0 – 170) mg/l Metoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids Range: (5,0 – 170) mg/l Gravimetric method PN-EN 872:2007 + Ap1:2007","search_zh":"水、废水 PN-EN 872:2007 + Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55f59af9f73f38251b01","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali Zakres: - ołów (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedź (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali Zakres: - olow (0,100 – 10,0) mg/l - kadm (0,100 – 10,0) mg/l - nikiel (0,100 – 10,0) mg/l - miedz (0,100 – 10,0) mg/l - cynk (0,100 – 10,0) mg/l - chrom (0,100 – 10,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Metal concentrations Range: - lead (0,100 – 10,0) mg/l - cadmium (0,100 – 10,0) mg/l - nickel (0,100 – 10,0) mg/l - copper (0,100 – 10,0) mg/l - zinc (0,100 – 10,0) mg/l - chromium (0,100 – 10,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、废水 PN-EN ISO 11885:2009","test_object_zh":"水、废水"},{"_id":"6a5a55f59af9f73f38251b02","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB-09 wydanie 2 z dnia 15.03.2024 r.","norm_bases":["PB-09 wydanie 2 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-09 wydanie 2 z dnia 15.03.2024 r. Woda, scieki Stezenie rteci Zakres: (0,00010 – 0,200) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-09 wydanie 2 z dnia 15.03.2024 r.","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mercury concentration Range: (0,00010 – 0,200) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) PB-09 wydanie 2 z dnia 15.03.2024 r.","search_zh":"水、废水 PB-09 wydanie 2 z dnia 15.03.2024 r.","test_object_zh":"水、废水"},{"_id":"6a5a55f59af9f73f38251b03","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu VI Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Chromium VI concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu VI Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313","norm_bases":["PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu VI Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313 Woda, scieki Stezenie chromu VI Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chromium VI concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313","search_zh":"水、废水 PB-07 wydanie 6 z dnia 23.08.2022 r na podstawie testu kuwetowego LCK 313","test_object_zh":"水、废水"},{"_id":"6a5a55f59af9f73f38251b04","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","methodology_en":"Sampling for chemical and physical testing Manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 Woda Pobieranie probek do badan chemicznych i fizycznych Metoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5 i 7.6","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Manual method PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6","search_zh":"水 用于化学与物理检验的采样 手工法 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 手工法"},{"_id":"6a5a55f59af9f73f38251b05","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie anionów Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Scieki Stezenie anionow Zakres: - chlorki (10 – 40 000) mg/l - siarczany (10 – 40 000) mg/l - fluorki (1,0 – 2 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Anion concentrations Range: - chlorides (10 – 40 000) mg/l - sulfates (10 – 40 000) mg/l - fluorides (1,0 – 2 500) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009","search_zh":"污水 PN-EN ISO 10304-1:2009","test_object_zh":"污水"},{"_id":"6a5a55f59af9f73f38251b06","lab_id":"69ad52a3de79e566650fb67c","country":"PL","accr_number":"AB 1267","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","methodology_en":"Sampling for chemical and physical testing Manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","reference":"PN-ISO 5667-10:2021-11 z wyłączeniem pkt.5.4","norm_bases":["PN-ISO 5667-10:2021-11 z wyłączeniem pkt.5.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11 z wyłączeniem pkt.5.4 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11 z wylaczeniem pkt.5.4","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11 z wyłączeniem pkt.5.4","search_zh":"污水 用于化学与物理检验的采样 手工法 PN-ISO 5667-10:2021-11 z wyłączeniem pkt.5.4","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工法"}],"has_pdf":true}