{"lab":{"_id":"69ad52a3de79e566650fb66c","accr_number":"AB 1255","country":"PL","accr_body":"PCA","address":"USŁUGI W ZAKRESIE OCHRONY ŚRODOWISKA, Klara Szczepańska, Krusza Duchowna 47, 88-101 Inowrocław","categories":["environment","construction","materials"],"city":"Inowrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"EKOLAB","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1255.pdf"],"scope_summary":"","search_text":"ekolab usługi w zakresie ochrony środowiska, klara szczepańska, krusza duchowna 47, 88-101 inowrocław materials environment construction electronics other metrology pharma","status":"active","updated_at":"2026-03-08T14:50:25.686Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:25.686Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201255,podmiot.html","parse_date":"2026-07-20T07:09:27.182Z","parse_source":"script-pdfplumber","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors -noise and lighting)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"issue":{"no":"13","date":"21.02.2025"},"map_coord":[52.795241,18.259562],"map_geo":"nominatim-city","has_en":true,"category_counts":{"environment":9,"other":3,"construction":2,"materials":1},"category_scores":{"environment":5.4,"other":0.6,"construction":0.27,"materials":0.07},"has_zh":true},"methods":[{"_id":"6a5dc9a7f1c10c8ce8259927","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym:"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym:"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne"},{"name":"frakcja respirabilna"}],"parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including:"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including:"},{"name":"inhalable fraction"},{"name":"inorganic substances"},{"name":"respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction metals and their compounds, including: inhalable fraction respirable fraction organic substances, including: inhalable fraction inorganic substances respirable fraction PN-Z-04008-7:2002 + Az1:2004","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，其中包括："},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，其中包括："},{"name":"可吸入组分"},{"name":"无机物质"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，其中包括： 可吸入组分 呼吸性组分 有机物质，其中包括： 可吸入组分 无机物质 呼吸性组分 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9a7f1c10c8ce8259928","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9a7f1c10c8ce8259929","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna:","methodology_en":"Concentration of harmful dust agents inhalable fraction:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,21 – 20,00) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,21 – 20,00) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,21 – 20,00) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,21 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,21 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents inhalable fraction: Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05+Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,21 – 20,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9a7f1c10c8ce825992a","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,22 – 17,54) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,22 – 17,54) mg/m3"}],"technique":"Metoda grawimetryczna cechy/metoda","techniques":["Metoda grawimetryczna cechy/metoda"],"technique_en":"Gravimetric method characteristics/method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,22 – 17,54) mg/m3\nMetoda grawimetryczna cechy/metoda","reference":"PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,22 – 17,54) mg/m3\nMetoda grawimetryczna cechy/metoda PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,22 – 17,54) mg/m3\nMetoda grawimetryczna cechy/metoda PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method characteristics/method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05+Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,22 – 17,54) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 特征/方法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05+Ap1:2022-08","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘：","technique_zh":"重量法 特征/方法"},{"_id":"6a5dc9a7f1c10c8ce825992b","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise A-weighted equivalent sound pressure level PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","methodology_zh":"A 计权等效声级","search_zh":"工作场所环境 — 噪声 A 计权等效声级 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9a7f1c10c8ce825992c","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Maksymalny poziomu dźwięku A","methodology_en":"Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(28,0 - 125,0) dB"}],"parameters_en":[{"name":"Range","range":"(28,0 - 125,0) dB"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalny poziomu dźwięku A\nZakres (28,0 - 125,0) dB","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Maksymalny poziomu dźwięku A\nZakres (28,0 - 125,0) dB PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Srodowisko pracy - halas Maksymalny poziomu dzwieku A\nZakres (28,0 - 125,0) dB PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise Maximum A-weighted sound level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","parameters_zh":[{"name":"范围","range":"(28,0 - 125,0) dB"}],"search_zh":"工作场所环境 — 噪声 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9a7f1c10c8ce825992d","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Szczytowy poziom dźwięku C","methodology_en":"C-weighted peak sound pressure level","parameters":[{"name":"Zakres","range":"(33,0 - 138,0) dB"}],"parameters_en":[{"name":"Range","range":"(33,0 - 138,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Szczytowy poziom dźwięku C\nZakres (33,0 - 138,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Szczytowy poziom dźwięku C\nZakres (33,0 - 138,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Srodowisko pracy - halas Szczytowy poziom dzwieku C\nZakres (33,0 - 138,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise C-weighted peak sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(33,0 - 138,0) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9a7f1c10c8ce825992e","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","test_object_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","methodology":"Poziom ekspozycji odniesiony do:","methodology_en":"Exposure level normalised to:","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji odniesiony do:","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Poziom ekspozycji odniesiony do: PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) Poziom ekspozycji odniesiony do: PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated) Exposure level normalised to: PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","search_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","test_object_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）"},{"_id":"6a5dc9a7f1c10c8ce825992f","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","test_object_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","methodology":"− 8 godzinnego dobowego wymiaru czasu pracy","methodology_en":"− for an 8-hour daily working time","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"− 8 godzinnego dobowego wymiaru czasu pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) − 8 godzinnego dobowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) − 8 godzinnego dobowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated) − for an 8-hour daily working time PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","search_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","test_object_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）"},{"_id":"6a5dc9a7f1c10c8ce8259930","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","test_object_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","methodology":"− przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"− the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"− przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11 Poziom ekspozycji odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – pkt. 10 strategie 3 – pkt. 11","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated) − the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","search_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt. 10 strategię 3 – pkt. 11","test_object_zh":"暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）"},{"_id":"6a5dc9a7f1c10c8ce8259931","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(5 - 5000) lx"}],"parameters_en":[{"name":"Range","range":"(5 - 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (5 - 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 - 5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 - 5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 - 5000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9a7f1c10c8ce8259932","lab_id":"69ad52a3de79e566650fb66c","country":"PL","accr_number":"AB 1255","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"}],"has_pdf":true}