{"lab":{"_id":"69ad52a3de79e566650fb666","accr_number":"AB 1250","country":"PL","accr_body":"PCA","address":"LABORATORIUM ANALITYCZNE, Szarlej 18, 88-150 Kruszwica","categories":["water"],"city":"Kruszwica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":32,"name":"SPÓŁKA WODNO-ŚCIEKOWA W KRUSZWICY","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1250.pdf"],"scope_summary":"","search_text":"spółka wodno-ściekowa w kruszwicy laboratorium analityczne, szarlej 18, 88-150 kruszwica water pharma electronics other","status":"active","updated_at":"2026-03-08T14:50:25.475Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:13:37.009Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201250,podmiot.html","parse_date":"2026-08-13T08:13:37.009Z","parse_source":"agent-claude-code","map_coord":[52.67438,18.325477],"map_geo":"nominatim-city","fields_of_testing":[{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"C/28/P","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"N/28/P","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"16","date":"17.12.2024"},"lab_locations":[{"name":"LABORATORIUM ANALITYCZNE","address":"88-150 Kruszwica","city":"Kruszwica","postal":"88-150"},{"name":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/9eaa7f3b103b256296dda3186e32d1d8/AB%201250.pdf","has_en":true,"category_counts":{"water":32,"microbiology":1},"category_scores":{"water":31.03,"microbiology":0.03},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM ANALITYCZNE","address":"88-150 Kruszwica","city":"Kruszwica","postal":"88-150"},{"name":"分析实验室；Szarlej 18, 88-150 Kruszwica","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7cb10636ba417e41c87f","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,04 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,04 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 200) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 200) mg/l"}],"search_zh":"生活饮用水、废水 氨氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c880","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,020 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,020 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB – 05, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 303 LCK 304","norm_bases":["PB – 05, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 303 LCK 304"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,020 – 200) mg/l\nMetoda spektrofotometryczna PB – 05, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 303 LCK 304 Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,020 – 200) mg/l\nMetoda spektrofotometryczna PB – 05, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 303 LCK 304","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,020 – 200) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 05, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 303 LCK 304","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 200) mg/l"}],"search_zh":"生活饮用水、废水 氨氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 05, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 303 LCK 304","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c881","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,00) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1,00) mg/l"}],"search_zh":"生活饮用水、废水 亚硝态氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN 26777:1999","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c882","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,015 – 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,015 – 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PB – 06, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 341","norm_bases":["PB – 06, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 341"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,015 – 0,60) mg/l\nMetoda spektrofotometryczna PB – 06, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 341 Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,015 – 0,60) mg/l\nMetoda spektrofotometryczna PB – 06, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 341","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,015 – 0,60) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 06, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 341","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 0,60) mg/l"}],"search_zh":"生活饮用水、废水 亚硝态氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 06, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 341","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c883","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,25 – 13,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,25 – 13,5) mg/l\nMetoda spektrofotometryczna","reference":"PB – 07, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 339","norm_bases":["PB – 07, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 339"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,25 – 13,5) mg/l\nMetoda spektrofotometryczna PB – 07, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 339 Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,25 – 13,5) mg/l\nMetoda spektrofotometryczna PB – 07, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 339","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,25 – 13,5) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrate nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 07, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 13,5) mg/l"}],"search_zh":"生活饮用水、废水 硝态氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 07, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 339","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c884","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(5,00 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (5,00 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB – 08, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 238 LCK 338","norm_bases":["PB – 08, wydanie 4 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 238 LCK 338"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu ogólnego\nZakres (5,00 – 200) mg/l\nMetoda spektrofotometryczna PB – 08, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 238 LCK 338 Woda do spozycia przez ludzi, Scieki Stezenie azotu ogolnego\nZakres (5,00 – 200) mg/l\nMetoda spektrofotometryczna PB – 08, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 238 LCK 338","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,00 – 200) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Total nitrogen concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 08, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 238 LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 200) mg/l"}],"search_zh":"生活饮用水、废水 总氮浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 08, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 238 LCK 338","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c885","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB – 09, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350","norm_bases":["PB – 09, wydanie 4 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PB – 09, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350 Woda do spozycia przez ludzi, Scieki Stezenie fosforu ogolnego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PB – 09, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Total phosphorus concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 09, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"生活饮用水、废水 总磷浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 09, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 348 LCK 349 LCK 350","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d7cb10636ba417e41c886","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6 000) mg /l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6 000) mg /l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6 000) mg /l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6 000) mg /l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6 000) mg /l O2"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Electrochemical method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6 000) mg /l O2"}],"search_zh":"水、废水、雨水与融雪水 生化需氧量 电化学法 分析实验室；Szarlej 18, 88-150 Kruszwica BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c887","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg /l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg /l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg /l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg /l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg /l O2"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Electrochemical method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg /l O2"}],"search_zh":"水、废水、雨水与融雪水 生化需氧量 电化学法 分析实验室；Szarlej 18, 88-150 Kruszwica BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c888","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5 000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 5 000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, Scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 5 000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5 000) mg/l"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5 000) mg/l"}],"search_zh":"水、废水、雨水与融雪水 总悬浮物 重量法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c889","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 2 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 2 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie chlorków\nZakres (5,0 – 2 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie chlorkow\nZakres (5,0 – 2 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 2 000) mg/l"}],"search_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water Chloride concentration Titrimetric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2 000) mg/l"}],"search_zh":"生活饮用水、废水、雨水与融雪水 氯化物浓度 滴定法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-ISO 9297:1994","technique_zh":"滴定法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c88a","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1 000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1 000) mg/l\nMetoda spektrofotometryczna","reference":"PB – 10, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 311","norm_bases":["PB – 10, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 311"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie chlorków\nZakres (5,0 – 1 000) mg/l\nMetoda spektrofotometryczna PB – 10, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 311 Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie chlorkow\nZakres (5,0 – 1 000) mg/l\nMetoda spektrofotometryczna PB – 10, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 311","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1 000) mg/l"}],"search_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water Chloride concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 10, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 311","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1 000) mg/l"}],"search_zh":"生活饮用水、废水、雨水与融雪水 氯化物浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 10, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 311","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c88b","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,02 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,02 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016","norm_bases":["PN-ISO 6332:2001+Ap1:2016"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie żelaza\nZakres (0,02 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016 Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie zelaza\nZakres (0,02 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,02 – 5,00) mg/l"}],"search_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water Iron concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-ISO 6332:2001+Ap1:2016","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 5,00) mg/l"}],"search_zh":"生活饮用水、废水、雨水与融雪水 铁浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-ISO 6332:2001+Ap1:2016","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c88c","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,01 – 6,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,01 – 6,00) mg/l\nMetoda spektrofotometryczna","reference":"PB – 11, wydanie 4 z dnia 09.03.2020 r. | na podstawie testu Hach-Lange LCK 521 LCK 321","norm_bases":["PB – 11, wydanie 4 z dnia 09.03.2020 r.","na podstawie testu Hach-Lange LCK 521 LCK 321"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie żelaza\nZakres (0,01 – 6,00) mg/l\nMetoda spektrofotometryczna PB – 11, wydanie 4 z dnia 09.03.2020 r. | na podstawie testu Hach-Lange LCK 521 LCK 321 Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie zelaza\nZakres (0,01 – 6,00) mg/l\nMetoda spektrofotometryczna PB – 11, wydanie 4 z dnia 09.03.2020 r. | na podstawie testu Hach-Lange LCK 521 LCK 321","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 6,00) mg/l"}],"search_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water Iron concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 11, wydanie 4 z dnia 09.03.2020 r. | na podstawie testu Hach-Lange LCK 521 LCK 321","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 6,00) mg/l"}],"search_zh":"生活饮用水、废水、雨水与融雪水 铁浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 11, wydanie 4 z dnia 09.03.2020 r. | na podstawie testu Hach-Lange LCK 521 LCK 321","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c88d","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40,0 – 800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (40,0 – 800) mg/l\nMetoda spektrofotometryczna","reference":"PB – 12, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 153 LCK 353","norm_bases":["PB – 12, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 153 LCK 353"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie siarczanów\nZakres (40,0 – 800) mg/l\nMetoda spektrofotometryczna PB – 12, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 153 LCK 353 Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie siarczanow\nZakres (40,0 – 800) mg/l\nMetoda spektrofotometryczna PB – 12, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 153 LCK 353","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40,0 – 800) mg/l"}],"search_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water Sulfate concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 12, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 153 LCK 353","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40,0 – 800) mg/l"}],"search_zh":"生活饮用水、废水、雨水与融雪水 硫酸盐浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 12, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 153 LCK 353","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"生活饮用水、废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c88e","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe, Woda do spożycia przez ludzi pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki, Wody opadowe i roztopowe, Woda do spozycia przez ludzi pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water, Water intended for human consumption pH Potentiometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"pH 值 电位法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c88f","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(15,0 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Wody opadowe i roztopowe Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(15,0 – 10 000) mg/l O2"}],"search_en":"Wastewater, Rainwater and snowmelt water Chemical oxygen demand - COD Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Rainwater and snowmelt water","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(15,0 – 10 000) mg/l O2"}],"search_zh":"废水、雨水与融雪水 化学需氧量 ChZT（COD） 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c890","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 5 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (5 – 5 000) mg/l\nMetoda wagowa","reference":"PB – 04, wydanie 4 z dnia 05.09.2019 r.","norm_bases":["PB – 04, wydanie 4 z dnia 05.09.2019 r."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Substancje ekstrahujące się eterem naftowym\nZakres (5 – 5 000) mg/l\nMetoda wagowa PB – 04, wydanie 4 z dnia 05.09.2019 r. Scieki, Wody opadowe i roztopowe Substancje ekstrahujace sie eterem naftowym\nZakres (5 – 5 000) mg/l\nMetoda wagowa PB – 04, wydanie 4 z dnia 05.09.2019 r.","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 5 000) mg/l"}],"search_en":"Wastewater, Rainwater and snowmelt water Substances extractable with petroleum ether Gravimetric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 04, wydanie 4 z dnia 05.09.2019 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(5 – 5 000) mg/l"}],"search_zh":"废水、雨水与融雪水 石油醚可萃取物 重量法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 04, wydanie 4 z dnia 05.09.2019 r.","technique_zh":"重量法","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","methodology_zh":"石油醚可萃取物","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a7d7cb10636ba417e41c891","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(50 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (50 – 10 000) mg/l\nMetoda wagowa","reference":"PN-C-04541:1978 pkt. 4.4","norm_bases":["PN-C-04541:1978 pkt. 4.4"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje rozpuszczone\nZakres (50 – 10 000) mg/l\nMetoda wagowa PN-C-04541:1978 pkt. 4.4 Scieki Substancje rozpuszczone\nZakres (50 – 10 000) mg/l\nMetoda wagowa PN-C-04541:1978 pkt. 4.4","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(50 – 10 000) mg/l"}],"search_en":"Wastewater Dissolved solids Gravimetric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-C-04541:1978 pkt. 4.4","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(50 – 10 000) mg/l"}],"search_zh":"污水 溶解性固体 重量法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-C-04541:1978 pkt. 4.4","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","methodology_zh":"溶解性固体"},{"_id":"6a7d7cb10636ba417e41c892","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015 metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015 metoda C"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015 metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015 metoda C","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 100) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN ISO 7887:2012+Ap1:2015 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN ISO 7887:2012+Ap1:2015 metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c893","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 20) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 20) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c894","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB – 14, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCW 032","norm_bases":["PB – 14, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCW 032"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PB – 14, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCW 032 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PB – 14, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCW 032","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 14, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCW 032","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 14, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCW 032","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c895","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(50,0 – 700) mg/l CaCO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Twardość ogólna\nZakres (50,0 – 700) mg/l CaCO3\nMetoda spektrofotometryczna","reference":"PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","norm_bases":["PB – 15, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 327"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Twardość ogólna\nZakres (50,0 – 700) mg/l CaCO3\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327 Woda do spozycia przez ludzi Twardosc ogolna\nZakres (50,0 – 700) mg/l CaCO3\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(50,0 – 700) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total hardness Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(50,0 – 700) mg/l CaCO3"}],"search_zh":"生活饮用水 总硬度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","methodology_zh":"总硬度"},{"_id":"6a7d7cb10636ba417e41c896","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(10,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie wapnia\nZakres (10,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","norm_bases":["PB – 15, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 327"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wapnia\nZakres (10,0 – 200) mg/l\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327 Woda do spozycia przez ludzi Stezenie wapnia\nZakres (10,0 – 200) mg/l\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(10,0 – 200) mg/l"}],"search_en":"Water intended for human consumption Calcium concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10,0 – 200) mg/l"}],"search_zh":"生活饮用水 钙浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"钙浓度","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c897","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(10,0 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie magnezu\nZakres (10,0 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","norm_bases":["PB – 15, wydanie 3 z dnia 05.09.2019 r.","na podstawie testu Hach-Lange LCK 327"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie magnezu\nZakres (10,0 – 100) mg/l\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327 Woda do spozycia przez ludzi Stezenie magnezu\nZakres (10,0 – 100) mg/l\nMetoda spektrofotometryczna PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(10,0 – 100) mg/l"}],"search_en":"Water intended for human consumption Magnesium concentration Spectrophotometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10,0 – 100) mg/l"}],"search_zh":"生活饮用水 镁浓度 分光光度法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 15, wydanie 3 z dnia 05.09.2019 r. | na podstawie testu Hach-Lange LCK 327","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","methodology_zh":"镁浓度"},{"_id":"6a7d7cb10636ba417e41c898","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 10 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 10 000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 10 000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c899","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Zapach Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"(1 – 4)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Zapach Liczba progowa zapachu (TON)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PB – 16, wydanie 4 z dnia 05.09.2019 r.","norm_bases":["PB – 16, wydanie 4 z dnia 05.09.2019 r."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Zapach Liczba progowa zapachu (TON)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony PB – 16, wydanie 4 z dnia 05.09.2019 r. Woda do spozycia przez ludzi Zapach Liczba progowa zapachu (TON)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybor niewymuszony PB – 16, wydanie 4 z dnia 05.09.2019 r.","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Odour Threshold odour number (TON)","parameters_en":[{"name":"Range","range":"(1 – 4)"}],"search_en":"Water intended for human consumption Odour Threshold odour number (TON) Simplified method, paired, non-forced choice Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 16, wydanie 4 z dnia 05.09.2019 r.","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 4)"}],"search_zh":"生活饮用水 简化法，成对，非强制选择 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 16, wydanie 4 z dnia 05.09.2019 r.","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c89a","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Smak Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"(1 – 4)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Smak Liczba progowa smaku (TFN)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PB – 16, wydanie 4 z dnia 05.09.2019 r.","norm_bases":["PB – 16, wydanie 4 z dnia 05.09.2019 r."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Smak Liczba progowa smaku (TFN)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony PB – 16, wydanie 4 z dnia 05.09.2019 r. Woda do spozycia przez ludzi Smak Liczba progowa smaku (TFN)\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybor niewymuszony PB – 16, wydanie 4 z dnia 05.09.2019 r.","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Taste Taste threshold number (TFN)","parameters_en":[{"name":"Range","range":"(1 – 4)"}],"search_en":"Water intended for human consumption Taste Taste threshold number (TFN) Simplified method, paired, non-forced choice Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 16, wydanie 4 z dnia 05.09.2019 r.","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 4)"}],"search_zh":"生活饮用水 简化法，成对，非强制选择 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 16, wydanie 4 z dnia 05.09.2019 r.","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c89b","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna","reference":"PB – 17, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach nr 2105560","norm_bases":["PB – 17, wydanie 4 z dnia 05.09.2019 r.","na podstawie testu Hach nr 2105560"],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB – 17, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach nr 2105560 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB – 17, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach nr 2105560","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Colorimetric method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Range PB – 17, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach nr 2105560","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 比色法 分析实验室；Szarlej 18, 88-150 Kruszwica 范围 PB – 17, wydanie 4 z dnia 05.09.2019 r. | na podstawie testu Hach nr 2105560","technique_zh":"比色法","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c89c","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Pobieranie próbek ścieków do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura ścieków"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek ścieków do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków\nZakres (0,5 – 50) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","norm_bases":["PN-ISO 5667-10:2021-11","PB – 01, wydanie 5 z dnia 01.09.2017 r."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek ścieków do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków\nZakres (0,5 – 50) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB – 01, wydanie 5 z dnia 01.09.2017 r. Scieki, Wody opadowe i roztopowe Pobieranie probek sciekow do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow\nZakres (0,5 – 50) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Sampling of wastewater for chemical and physical testing","parameters_en":[{"name":"Wastewater temperature"},{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Wastewater, Rainwater and snowmelt water Sampling of wastewater for chemical and physical testing Manual and automatic method Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Wastewater temperature Range PN-ISO 5667-10:2021-11 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","technique_en":"Manual and automatic method","test_object_en":"Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"废水温度"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"废水、雨水与融雪水 用于化学与物理检验的废水采样 手工与自动法 分析实验室；Szarlej 18, 88-150 Kruszwica 废水温度 范围 PN-ISO 5667-10:2021-11 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica","technique_zh":"手工与自动法","test_object_zh":"废水、雨水与融雪水","methodology_zh":"用于化学与物理检验的废水采样"},{"_id":"6a7d7cb10636ba417e41c89d","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[{"name":"Temperatura wody"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (0,5 – 50) °C","reference":"PN-ISO 5667-5:2017-10 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","norm_bases":["PN-ISO 5667-5:2017-10","PB – 01, wydanie 5 z dnia 01.09.2017 r."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (0,5 – 50) °C PN-ISO 5667-5:2017-10 | PB – 01, wydanie 5 z dnia 01.09.2017 r. Woda do spozycia przez ludzi Pobieranie probek wody do badan chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (0,5 – 50) °C PN-ISO 5667-5:2017-10 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Water sampling for chemical and physical testing (including sensory)","parameters_en":[{"name":"Water temperature"},{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Water intended for human consumption Water sampling for chemical and physical testing (including sensory) Analytical Laboratory; Szarlej 18, 88-150 Kruszwica Water temperature Range PN-ISO 5667-5:2017-10 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"水温"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"生活饮用水 分析实验室；Szarlej 18, 88-150 Kruszwica 水温 范围 PN-ISO 5667-5:2017-10 | PB – 01, wydanie 5 z dnia 01.09.2017 r.","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"},{"_id":"6a7d7cb10636ba417e41c89e","lab_id":"69ad52a3de79e566650fb666","country":"PL","accr_number":"AB 1250","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4.","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4."],"lab_section":"Laboratorium Analityczne; Szarlej 18, 88-150 Kruszwica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4. Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.3; 4.4.4.","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Analytical Laboratory; Szarlej 18, 88-150 Kruszwica","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Analytical Laboratory; Szarlej 18, 88-150 Kruszwica PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4.","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 分析实验室；Szarlej 18, 88-150 Kruszwica PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4.","test_object_zh":"生活饮用水","lab_section_zh":"分析实验室；Szarlej 18, 88-150 Kruszwica"}],"has_pdf":true}