{"lab":{"_id":"69ad52a3de79e566650fb660","accr_number":"AB 1245","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Szypowskiego 1, 39-460 Nowa Dęba","categories":["water","environment","construction"],"city":"Nowa Dęba","imported_at":"2026-03-08T10:42:43.265Z","methods_count":31,"name":"ZAKŁADY METALOWE DEZAMET S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1245.pdf"],"scope_summary":"","search_text":"zakłady metalowe dezamet s.a. laboratorium badawcze, ul. szypowskiego 1, 39-460 nowa dęba water other pharma electronics environment metrology materials construction","status":"active","updated_at":"2026-03-08T14:50:25.264Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:25.264Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201245,podmiot.html","parse_date":"2026-07-17T16:19:00.549Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek, wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting)"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek, wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze","en":"Tests of physical properties and sampling - working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling - working environment (harmful factors – air)"}],"issue":{"no":"18","date":"07.01.2026"},"map_coord":[50.414197,21.747398],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":20,"environment":10,"construction":2,"other":1,"materials":1},"category_scores":{"water":11.76,"environment":2.94,"construction":0.12,"other":0.03,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a5a55f49af9f73f3825197b","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"PCA","test_object_en":"PCA","methodology":"Zakres akredytacji Nr AB 1245 Scope of accreditation No. AB 1245","methodology_en":"Scope of accreditation No. AB 1245","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zakres akredytacji Nr AB 1245 Scope of accreditation No. AB 1245","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"PCA Zakres akredytacji Nr AB 1245 Scope of accreditation No. AB 1245 PCA Zakres akredytacji Nr AB 1245 Scope of accreditation No. AB 1245","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"PCA Scope of accreditation No. AB 1245","search_zh":"PCA","test_object_zh":"PCA"},{"_id":"6a5a55f49af9f73f3825197c","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10 – 1500) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD Range: (10 – 1500) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10 – 1500) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10 – 1500) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10 – 1500) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD Range: (10 – 1500) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825197d","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (5,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (5,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids (TSS) Range: (5,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825197e","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、生活饮用水、污水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水、污水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55f49af9f73f3825197f","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (80 – 5000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa Zakres: (80 – 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Range: (80 – 5000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水、污水 PN-EN 27888:1999","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251980","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,010 – 3,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna","reference":"PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752","norm_bases":["PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Range: (0,010 – 3,00) mg/l Spectrophotometric method PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752","search_zh":"水、生活饮用水、污水 PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251981","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,2 – 20,0) mg/l Stężenie azotu ogólnego Zakres: (0,5 – 15,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,2 – 20,0) mg/l Total nitrogen concentration Range: (0,5 – 15,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,2 – 20,0) mg/l Stężenie azotu ogólnego Zakres: (0,5 – 15,0) mg/l Metoda spektrofotometryczna","reference":"PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773","norm_bases":["PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego Zakres: (0,2 – 20,0) mg/l Stężenie azotu ogólnego Zakres: (0,5 – 15,0) mg/l Metoda spektrofotometryczna PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego Zakres: (0,2 – 20,0) mg/l Stezenie azotu ogolnego Zakres: (0,5 – 15,0) mg/l Metoda spektrofotometryczna PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Range: (0,2 – 20,0) mg/l Total nitrogen concentration Range: (0,5 – 15,0) mg/l Spectrophotometric method PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773","search_zh":"水、生活饮用水、污水 PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251982","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,002 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,002 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,002 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776","norm_bases":["PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotynowego Zakres: (0,002 – 1,00) mg/l Metoda spektrofotometryczna PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotynowego Zakres: (0,002 – 1,00) mg/l Metoda spektrofotometryczna PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Nitrite nitrogen concentration Range: (0,002 – 1,00) mg/l Spectrophotometric method PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776","search_zh":"水、生活饮用水、污水 PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251983","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chlorków Zakres: (2,5 – 250) mg/l Metoda spektrofotometryczna","methodology_en":"Chloride concentration Range: (2,5 – 250) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (2,5 – 250) mg/l Metoda spektrofotometryczna","reference":"PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897","norm_bases":["PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków Zakres: (2,5 – 250) mg/l Metoda spektrofotometryczna PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow Zakres: (2,5 – 250) mg/l Metoda spektrofotometryczna PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Chloride concentration Range: (2,5 – 250) mg/l Spectrophotometric method PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897","search_zh":"水、生活饮用水、污水 PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251984","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chromu (VI) i chromu ogólnego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna Stężenie chromu (III) (z obliczeń)","methodology_en":"Chromium (VI) and total chromium concentration Range: (0,010 – 3,00) mg/l Spectrophotometric method Chromium (III) concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu (VI) i chromu ogólnego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna Stężenie chromu (III) (z obliczeń)","reference":"PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758","norm_bases":["PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chromu (VI) i chromu ogólnego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna Stężenie chromu (III) (z obliczeń) PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758 Woda, woda do spozycia przez ludzi, scieki Stezenie chromu (VI) i chromu ogolnego Zakres: (0,010 – 3,00) mg/l Metoda spektrofotometryczna Stezenie chromu (III) (z obliczen) PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Chromium (VI) and total chromium concentration Range: (0,010 – 3,00) mg/l Spectrophotometric method Chromium (III) concentration (calculated) PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758","search_zh":"水、生活饮用水、污水 PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251985","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie cyjanków wolnych Zakres: (0,0020 – 0,500) mg/l Stężenie cyjanków ogólnych Zakres: (0,0020 – 0,500) mg/l Metoda spektrofotometryczna Stężenie cyjanków związanych (z obliczeń)","methodology_en":"Free cyanide concentration Range: (0,0020 – 0,500) mg/l Total cyanide concentration Range: (0,0020 – 0,500) mg/l Spectrophotometric method Bound cyanide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych Zakres: (0,0020 – 0,500) mg/l Stężenie cyjanków ogólnych Zakres: (0,0020 – 0,500) mg/l Metoda spektrofotometryczna Stężenie cyjanków związanych (z obliczeń)","reference":"PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701","norm_bases":["PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie cyjanków wolnych Zakres: (0,0020 – 0,500) mg/l Stężenie cyjanków ogólnych Zakres: (0,0020 – 0,500) mg/l Metoda spektrofotometryczna Stężenie cyjanków związanych (z obliczeń) PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701 Woda, woda do spozycia przez ludzi, scieki Stezenie cyjankow wolnych Zakres: (0,0020 – 0,500) mg/l Stezenie cyjankow ogolnych Zakres: (0,0020 – 0,500) mg/l Metoda spektrofotometryczna Stezenie cyjankow zwiazanych (z obliczen) PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Free cyanide concentration Range: (0,0020 – 0,500) mg/l Total cyanide concentration Range: (0,0020 – 0,500) mg/l Spectrophotometric method Bound cyanide concentration (calculated) PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701","search_zh":"水、生活饮用水、污水 PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251986","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie cynku Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna","methodology_en":"Zinc concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cynku Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna","reference":"PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832","norm_bases":["PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie cynku Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832 Woda, woda do spozycia przez ludzi, scieki Stezenie cynku Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Zinc concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832","search_zh":"水、生活饮用水、污水 PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251987","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie fosforanów (ortofosforanów) Zakres: (0,20 – 15,30) mg/l Stężenie fosforu ogólnego Zakres: (0,05 – 5,00) mg/l Metoda spektrofotometryczna","methodology_en":"Phosphate (orthophosphate) concentration Range: (0,20 – 15,30) mg/l Total phosphorus concentration Range: (0,05 – 5,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów (ortofosforanów) Zakres: (0,20 – 15,30) mg/l Stężenie fosforu ogólnego Zakres: (0,05 – 5,00) mg/l Metoda spektrofotometryczna","reference":"PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848","norm_bases":["PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fosforanów (ortofosforanów) Zakres: (0,20 – 15,30) mg/l Stężenie fosforu ogólnego Zakres: (0,05 – 5,00) mg/l Metoda spektrofotometryczna PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848 Woda, woda do spozycia przez ludzi, scieki Stezenie fosforanow (ortofosforanow) Zakres: (0,20 – 15,30) mg/l Stezenie fosforu ogolnego Zakres: (0,05 – 5,00) mg/l Metoda spektrofotometryczna PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Phosphate (orthophosphate) concentration Range: (0,20 – 15,30) mg/l Total phosphorus concentration Range: (0,05 – 5,00) mg/l Spectrophotometric method PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848","search_zh":"水、生活饮用水、污水 PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251988","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie miedzi Zakres: (0,020 – 6,00) mg/l Metoda spektrofotometryczna","methodology_en":"Copper concentration Range: (0,020 – 6,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie miedzi Zakres: (0,020 – 6,00) mg/l Metoda spektrofotometryczna","reference":"PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767","norm_bases":["PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie miedzi Zakres: (0,020 – 6,00) mg/l Metoda spektrofotometryczna PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767 Woda, woda do spozycia przez ludzi, scieki Stezenie miedzi Zakres: (0,020 – 6,00) mg/l Metoda spektrofotometryczna PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Copper concentration Range: (0,020 – 6,00) mg/l Spectrophotometric method PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767","search_zh":"水、生活饮用水、污水 PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f38251989","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie niklu Zakres: (0,03 – 5,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nickel concentration Range: (0,03 – 5,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie niklu Zakres: (0,03 – 5,00) mg/l Metoda spektrofotometryczna","reference":"PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785","norm_bases":["PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie niklu Zakres: (0,03 – 5,00) mg/l Metoda spektrofotometryczna PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785 Woda, woda do spozycia przez ludzi, scieki Stezenie niklu Zakres: (0,03 – 5,00) mg/l Metoda spektrofotometryczna PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Nickel concentration Range: (0,03 – 5,00) mg/l Spectrophotometric method PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785","search_zh":"水、生活饮用水、污水 PB - 10/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114785","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f3825198a","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie siarczanów Zakres: (100 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Sulphate concentration Range: (100 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (100 – 1000) mg/l Metoda spektrofotometryczna","reference":"PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564","norm_bases":["PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów Zakres: (100 – 1000) mg/l Metoda spektrofotometryczna PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow Zakres: (100 – 1000) mg/l Metoda spektrofotometryczna PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Sulphate concentration Range: (100 – 1000) mg/l Spectrophotometric method PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564","search_zh":"水、生活饮用水、污水 PB - 12/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114564","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f3825198b","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie żelaza (III) i żelaza ogólnego Zakres: (0,010 – 5,00) mg/l Metoda spektrofotometryczna Stężenie żelaza (II) (z obliczeń)","methodology_en":"Concentration of iron (III) and total iron Range: (0,010 – 5,00) mg/l Spectrophotometric method Iron (II) concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza (III) i żelaza ogólnego Zakres: (0,010 – 5,00) mg/l Metoda spektrofotometryczna Stężenie żelaza (II) (z obliczeń)","reference":"PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796","norm_bases":["PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie żelaza (III) i żelaza ogólnego Zakres: (0,010 – 5,00) mg/l Metoda spektrofotometryczna Stężenie żelaza (II) (z obliczeń) PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796 Woda, woda do spozycia przez ludzi, scieki Stezenie zelaza (III) i zelaza ogolnego Zakres: (0,010 – 5,00) mg/l Metoda spektrofotometryczna Stezenie zelaza (II) (z obliczen) PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Concentration of iron (III) and total iron Range: (0,010 – 5,00) mg/l Spectrophotometric method Iron (II) concentration (calculated) PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796","search_zh":"水、生活饮用水、污水 PB - 14/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 100796","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f3825198c","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie anionów Zakres: chlorki (5 – 400) mg/l azotany (5 – 400) mg/l azot azotanowy (1,13 – 90,4) mg/l azotyny (0,025 – 0,500) mg/l azot azotynowy (0,008 – 0,152) mg/l siarczany (15 – 1200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: chlorides (5 – 400) mg/l nitrates (5 – 400) mg/l nitrate nitrogen (1,13 – 90,4) mg/l nitrites (0,025 – 0,500) mg/l nitrite nitrogen (0,008 – 0,152) mg/l sulfates (15 – 1200) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: chlorki (5 – 400) mg/l azotany (5 – 400) mg/l azot azotanowy (1,13 – 90,4) mg/l azotyny (0,025 – 0,500) mg/l azot azotynowy (0,008 – 0,152) mg/l siarczany (15 – 1200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie anionów Zakres: chlorki (5 – 400) mg/l azotany (5 – 400) mg/l azot azotanowy (1,13 – 90,4) mg/l azotyny (0,025 – 0,500) mg/l azot azotynowy (0,008 – 0,152) mg/l siarczany (15 – 1200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, woda do spozycia przez ludzi, scieki Stezenie anionow Zakres: chlorki (5 – 400) mg/l azotany (5 – 400) mg/l azot azotanowy (1,13 – 90,4) mg/l azotyny (0,025 – 0,500) mg/l azot azotynowy (0,008 – 0,152) mg/l siarczany (15 – 1200) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Anion concentrations Range: chlorides (5 – 400) mg/l nitrates (5 – 400) mg/l nitrate nitrogen (1,13 – 90,4) mg/l nitrites (0,025 – 0,500) mg/l nitrite nitrogen (0,008 – 0,152) mg/l sulfates (15 – 1200) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水、生活饮用水、污水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f3825198d","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metodą manualną i automatyczną Temperatura pobranej próbki ścieków Zakres: (0 – 50) °C","methodology_en":"Sampling for chemical and physical testing By manual and automatic method Temperature of the wastewater sample taken Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metodą manualną i automatyczną Temperatura pobranej próbki ścieków Zakres: (0 – 50) °C","reference":"PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","norm_bases":["PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metodą manualną i automatyczną Temperatura pobranej próbki ścieków Zakres: (0 – 50) °C PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r. Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej probki sciekow Zakres: (0 – 50) °C PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing By manual and automatic method Temperature of the wastewater sample taken Range: (0 – 50) °C PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","search_zh":"污水 PN-ISO 5667-10:2021-11 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f3825198e","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C","reference":"PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","norm_bases":["PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0 – 50) °C PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (0 – 50) °C PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","test_object_zh":"生活饮用水"},{"_id":"6a5a55f49af9f73f3825198f","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C","reference":"PN-EN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","norm_bases":["PN-EN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2","PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0 – 50) °C PN-EN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r. Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0 – 50) °C PN-EN-ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2 | PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0 – 50) °C PN-EN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","search_zh":"水 PN-EN-ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-11:2017-10 PN-88/C-04621 PB - 15/ZS Wydanie 1 z dnia 18.06.2019 r.","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f38251990","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (25 – 135) dB C-weighted peak sound level Range: (40 – 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 135) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkty 10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 – 135) dB Szczytowy poziom dźwięku C Zakres: (40 – 135) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (25 – 135) dB Szczytowy poziom dzwieku C Zakres: (40 – 135) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 – 135) dB C-weighted peak sound level Range: (40 – 135) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkty 10 i 11","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkty 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55f49af9f73f38251991","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"噪声暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）"},{"_id":"6a5a55f49af9f73f38251992","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (20 – 9836) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (20 – 9836) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (20 – 9836) lx Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (20 – 9836) lx Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (20 – 9836) lx Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – indoor electric lighting Illuminance Range: (20 – 9836) lx Direct measurement method PN-83/E-04040.03","search_zh":"工作场所环境 — 室内电气照明 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55f49af9f73f38251993","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55f49af9f73f38251994","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration transmitted to the human body","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 100) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz (z obliczeń)","methodology_en":"Frequency-weighted r.m.s. vibration acceleration Range: (0,5 – 100) m/s2 Direct measurement method Daily exposure, expressed as the energy-equivalent value for 8 hours of the vector sum of the frequency-weighted r.m.s. vibration accelerations determined for the three directional components (a , a a ) hwx hwy, hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations determined for the three directional components (a , a a ) hwx hwy, hwz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 100) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015","norm_bases":["PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 100) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a a ) hwx hwy, hwz (z obliczeń) PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015 Srodowisko pracy – drgania przenoszone na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,5 – 100) m/s2 Metoda pomiarowa bezposrednia Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a a ) hwx hwy, hwz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a a ) hwx hwy, hwz (z obliczen) PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration transmitted to the human body Frequency-weighted r.m.s. vibration acceleration Range: (0,5 – 100) m/s2 Direct measurement method Daily exposure, expressed as the energy-equivalent value for 8 hours of the vector sum of the frequency-weighted r.m.s. vibration accelerations determined for the three directional components (a , a a ) hwx hwy, hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations determined for the three directional components (a , a a ) hwx hwy, hwz (calculated) PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015","search_zh":"工作环境 － 经上肢传递至人体的振动 PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015","test_object_zh":"工作环境 － 经上肢传递至人体的振动"},{"_id":"6a5a55f49af9f73f38251995","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,05 – 10) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz (z obliczeń)","methodology_en":"Frequency-weighted effective vibration acceleration Range: (0,05 – 10) m/s2 Direct measurement method Daily exposure, expressed as the energy-equivalent for 8 hours of action of the frequency-corrected effective vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (1,4·a , 1,4·a a ) wx wy, wz Exposure lasting 30 minutes and less, expressed as the frequency-weighted effective vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (1,4·a , 1,4·a a ) wx wy, wz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,05 – 10) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,05 – 10) m/s2 Metoda pomiarowa bezpośrednia Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4·a , 1,4·a a ) wx wy, wz (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,05 – 10) m/s2 Metoda pomiarowa bezposrednia Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4·a , 1,4·a a ) wx wy, wz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4·a , 1,4·a a ) wx wy, wz (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,05 – 10) m/s2 Direct measurement method Daily exposure, expressed as the energy-equivalent for 8 hours of action of the frequency-corrected effective vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (1,4·a , 1,4·a a ) wx wy, wz Exposure lasting 30 minutes and less, expressed as the frequency-weighted effective vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (1,4·a , 1,4·a a ) wx wy, wz (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5a55f49af9f73f38251996","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - związki nieorganiczne, w tym - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - dust agents - inhalable fraction - respirable fraction - inorganic compounds, including - respirable fraction - organic substances, including - inhalable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - związki nieorganiczne, w tym - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej","reference":"PN-Z-04008/07:2002+Az1:2004","norm_bases":["PN-Z-04008/07:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - związki nieorganiczne, w tym - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008/07:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na: - czynniki pylowe - frakcja wdychalna - frakcja respirabilna - zwiazki nieorganiczne, w tym - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - metale i ich zwiazki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008/07:2002+Az1:2004","categories":["materials","environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Sampling for occupational exposure assessment to: - dust agents - inhalable fraction - respirable fraction - inorganic compounds, including - respirable fraction - organic substances, including - inhalable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method PN-Z-04008/07:2002+Az1:2004","search_zh":"工作场所环境 — 空气 PN-Z-04008/07:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f49af9f73f38251997","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f49af9f73f38251998","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglan wapnia - Węglik krzemu, niewłóknisty Zakres: (0,14 – 20,0) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents - inhalable fraction - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Calcium carbonate - Silicon carbide, non-fibrous Range: (0,14 – 20,0) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglan wapnia - Węglik krzemu, niewłóknisty Zakres: (0,14 – 20,0) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych - frakcja wdychalna - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglan wapnia - Węglik krzemu, niewłóknisty Zakres: (0,14 – 20,0) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych - frakcja wdychalna - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyly drewna - Pyly maki - Pyly niesklasyfikowane ze wzgledu na toksycznosc - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Talk - Wegiel (kamienny, brunatny) - Weglan magnezu wapnia (dolomit) - Weglan wapnia - Weglik krzemu, niewloknisty Zakres: (0,14 – 20,0) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Calcium carbonate - Silicon carbide, non-fibrous Range: (0,14 – 20,0) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f49af9f73f38251999","lab_id":"69ad52a3de79e566650fb660","country":"PL","accr_number":"AB 1245","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,10 – 20,0) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents - respirable fraction - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) Range: (0,10 – 20,0) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,10 – 20,0) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych - frakcja respirabilna - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Talk - Węgiel (kamienny, brunatny) Zakres: (0,10 – 20,0) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych - frakcja respirabilna - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Talk - Wegiel (kamienny, brunatny) Zakres: (0,10 – 20,0) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Talc - Coal (hard, brown) Range: (0,10 – 20,0) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"}],"has_pdf":true}