{"lab":{"_id":"69ad52a3de79e566650fb652","accr_number":"AB 1228","country":"PL","accr_body":"PCA","address":"ul. Mszczonowska 4, 02-337 Warszawa, LABORATORIUM POMIARÓW JAKOŚCI GAZU, Pogórska Wola 450","categories":["petro","water"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"OPERATOR GAZOCIĄGÓW PRZESYŁOWYCH GAZ-SYSTEM S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1228.pdf"],"scope_summary":"","search_text":"operator gazociągów przesyłowych gaz-system s.a. ul. mszczonowska 4, 02-337 warszawa, laboratorium pomiarów jakości gazu, pogórska wola 450 petro other water environment metrology","status":"active","updated_at":"2026-03-08T14:50:24.620Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:24.620Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201228,podmiot.html","parse_date":"2026-07-17T16:19:00.237Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10/P","pl":"Badania chemiczne i pobieranie próbek paliw gazowych","en":"Chemical tests and sampling of gas fuels"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration)."},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/10","pl":"Badanie właściwości fizycznych paliw gazowych","en":"Tests of physical properties and sampling of gas fuels"},{"codes":"M/17","pl":"Badania inne procesowych chromatografów gazowych","en":"Other tests of process gas chromatographs"}],"issue":{"no":"20","date":"23.10.2025"},"map_coord":[52.213382,20.948821],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":10,"water":2},"category_scores":{"petro":8.33,"water":0.33},"has_zh":true},"methods":[{"_id":"6a5a55f49af9f73f382518b6","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Skład gazu w zakresie podstawowym","methodology_en":"Gas composition in the basic range","parameters":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"}],"parameters_en":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID)","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie podstawowym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021 | JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","norm_bases":["JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021","JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Skład gazu w zakresie podstawowym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID) JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021 | JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021 Paliwa gazowe: gaz ziemny, mieszaniny gazowe Sklad gazu w zakresie podstawowym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i detekcja plomieniowo- jonizacyjna (GC-FID) JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021 | JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures Gas composition in the basic range Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) N CO C C C i-C n-C i-C n-C C JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021 | JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","parameters_zh":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"}],"search_zh":"气体燃料：天然气、混合气体 基本范围内的气体组成 CO C C C C JA-PB-PgW-02 wydanie 8 z dnia 16.07.2021 | JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","test_object_zh":"气体燃料：天然气、混合气体","methodology_zh":"基本范围内的气体组成"},{"_id":"6a5a55f49af9f73f382518b7","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Skład gazu w zakresie rozszerzonym","methodology_en":"Gas composition in the extended range","parameters":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"},{"name":"C","range":"0,0001 – 0,02) %"},{"name":"C","range":"0,0001 – 0,02) %"}],"parameters_en":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"},{"name":"C","range":"0,0001 – 0,02) %"},{"name":"C","range":"0,0001 – 0,02) %"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID)","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie rozszerzonym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nC 0,0001 – 0,02) %\nC 0,0001 – 0,02) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","norm_bases":["JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Skład gazu w zakresie rozszerzonym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nC 0,0001 – 0,02) %\nC 0,0001 – 0,02) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i detekcją płomieniowo- jonizacyjną (GC-FID) JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021 Paliwa gazowe: gaz ziemny, mieszaniny gazowe Sklad gazu w zakresie rozszerzonym\nZakres:\nN 0,4 – 15) %\nCO 0,04 – 3) %\nC 80 – 99) %\nC 0,1 – 8) %\nC 0,01 – 1,5) %\ni-C 0,01 – 0,2) %\nn-C 0,01 – 0,2) %\ni-C 0,005 – 0,06) %\nn-C 0,003 – 0,06) %\nC 0,003 – 0,1) %\nC 0,0001 – 0,02) %\nC 0,0001 – 0,02) %\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i detekcja plomieniowo- jonizacyjna (GC-FID) JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures Gas composition in the extended range Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) N CO C C C i-C n-C i-C n-C C C C JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","parameters_zh":[{"name":"N","range":"0,4 – 15) %"},{"name":"CO","range":"0,04 – 3) %"},{"name":"C","range":"80 – 99) %"},{"name":"C","range":"0,1 – 8) %"},{"name":"C","range":"0,01 – 1,5) %"},{"name":"i-C","range":"0,01 – 0,2) %"},{"name":"n-C","range":"0,01 – 0,2) %"},{"name":"i-C","range":"0,005 – 0,06) %"},{"name":"n-C","range":"0,003 – 0,06) %"},{"name":"C","range":"0,003 – 0,1) %"},{"name":"C","range":"0,0001 – 0,02) %"},{"name":"C","range":"0,0001 – 0,02) %"}],"search_zh":"气体燃料：天然气、混合气体 CO C C C C C C JA-PB-PgW-03 wydanie 8 z dnia 22.07.2021","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518b8","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"górna","range":null},{"name":"dolna","range":null}],"parameters_en":[{"name":"upper","range":null},{"name":"lower","range":null}],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\ngórna\ndolna","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Ciepło spalania\nZakres:\ngórna\ndolna PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe Cieplo spalania\nZakres:\ngorna\ndolna PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures Gross calorific value upper lower PN-EN ISO 6976:2016-11","methodology_zh":"高位发热量","search_zh":"气体燃料：天然气、混合气体 高位发热量 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518b9","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"wartość opałowa","methodology_en":"net calorific value","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"wartość opałowa","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe wartość opałowa PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe wartosc opalowa PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures net calorific value PN-EN ISO 6976:2016-11","methodology_zh":"低位发热量","search_zh":"气体燃料：天然气、混合气体 低位发热量 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518ba","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"liczba Wobbego","methodology_en":"Wobbe index","parameters":[{"name":"górna","range":null},{"name":"dolna","range":null}],"parameters_en":[{"name":"upper","range":null},{"name":"lower","range":null}],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"liczba Wobbego\nZakres:\ngórna\ndolna","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe liczba Wobbego\nZakres:\ngórna\ndolna PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe liczba Wobbego\nZakres:\ngorna\ndolna PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures Wobbe index upper lower PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气、混合气体 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518bb","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"gęstość normalna","methodology_en":"normal density","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"gęstość normalna","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe gęstość normalna PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe gestosc normalna PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures normal density PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气、混合气体 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518bc","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"gęstość względna","methodology_en":"relative density","parameters":[],"parameters_en":[],"technique":"z obliczeń","technique_en":"calculated","computed":[],"computed_en":[],"activity":"gęstość względna\nz obliczeń","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe gęstość względna\nz obliczeń PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe gestosc wzgledna\nz obliczen PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas, gas mixtures relative density calculated PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气、混合气体 计算值 PN-EN ISO 6976:2016-11","technique_zh":"计算值","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5a55f49af9f73f382518bd","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Temperatura punktu rosy wody","methodology_en":"Water dew point temperature","parameters":[{"name":"Zakres","range":"(- 25 – 5) °C"}],"parameters_en":[{"name":"Range","range":"(- 25 – 5) °C"}],"technique":"Metoda kondensacji par na chłodzonej powierzchni lustra","technique_en":"Vapour condensation on a chilled mirror surface method","computed":[],"computed_en":[],"activity":"Temperatura punktu rosy wody\nZakres (- 25 – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra","reference":"PN-EN ISO 6327:2010","norm_bases":["PN-EN ISO 6327:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres (- 25 – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra PN-EN ISO 6327:2010 Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres (- 25 – 5) °C\nMetoda kondensacji par na chlodzonej powierzchni lustra PN-EN ISO 6327:2010","categories":["petro","water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas Water dew point temperature Vapour condensation on a chilled mirror surface method Range PN-EN ISO 6327:2010","parameters_zh":[{"name":"范围","range":"(- 25 – 5) °C"}],"search_zh":"气体燃料：天然气 水露点温度 冷却镜面凝露法 范围 PN-EN ISO 6327:2010","test_object_zh":"气体燃料：天然气","methodology_zh":"水露点温度","technique_zh":"冷却镜面凝露法"},{"_id":"6a5a55f49af9f73f382518be","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Pobieranie próbek jednostkowych gazu do badań chemicznych","methodology_en":"Sampling of individual gas samples for chemical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek jednostkowych gazu do badań chemicznych","reference":"PN-EN ISO 10715:2023-03 pkt. 7.2","norm_bases":["PN-EN ISO 10715:2023-03 pkt. 7.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Pobieranie próbek jednostkowych gazu do badań chemicznych PN-EN ISO 10715:2023-03 pkt. 7.2 Paliwa gazowe: gaz ziemny Pobieranie probek jednostkowych gazu do badan chemicznych PN-EN ISO 10715:2023-03 pkt. 7.2","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas Sampling of individual gas samples for chemical testing PN-EN ISO 10715:2023-03 pkt. 7.2","search_zh":"气体燃料：天然气 PN-EN ISO 10715:2023-03 pkt. 7.2","test_object_zh":"气体燃料：天然气"},{"_id":"6a5a55f49af9f73f382518bf","lab_id":"69ad52a3de79e566650fb652","country":"PL","accr_number":"AB 1228","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Przeliczanie temperatury punktu rosy wody z ciśnienia roboczego na ciśnienia odniesienia (z obliczeń","methodology_en":"Conversion of the water dew point temperature from working pressure to reference pressure (calculated","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przeliczanie temperatury punktu rosy wody z ciśnienia roboczego na ciśnienia odniesienia (z obliczeń","reference":"Standard Techniczny ST-IGG 0202:2024 Załącznik nr A","norm_bases":["Standard Techniczny ST-IGG 0202:2024 Załącznik nr A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Przeliczanie temperatury punktu rosy wody z ciśnienia roboczego na ciśnienia odniesienia (z obliczeń Standard Techniczny ST-IGG 0202:2024 Załącznik nr A Paliwa gazowe: gaz ziemny Przeliczanie temperatury punktu rosy wody z cisnienia roboczego na cisnienia odniesienia (z obliczen Standard Techniczny ST-IGG 0202:2024 Zalacznik nr A","categories":["petro","water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas Conversion of the water dew point temperature from working pressure to reference pressure (calculated Standard Techniczny ST-IGG 0202:2024 Załącznik nr A","search_zh":"气体燃料：天然气 Standard Techniczny ST-IGG 0202:2024 Załącznik nr A","test_object_zh":"气体燃料：天然气"}],"has_pdf":true}