{"lab":{"_id":"69ad52a3de79e566650fb646","accr_number":"AB 1220","country":"PL","accr_body":"PCA","address":"Al. Piłsudskiego 92 lok. 102 B, 41-308 Dąbrowa Górnicza, LABORATORIUM NOWA, Al. Piłsudskiego 92","categories":["petro"],"city":"Dąbrowa Górnicza","imported_at":"2026-03-08T10:42:43.265Z","methods_count":23,"name":"TAMEH POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1220.pdf"],"scope_summary":"","search_text":"tameh polska sp. z o.o. al. piłsudskiego 92 lok. 102 b, 41-308 dąbrowa górnicza, laboratorium nowa, al. piłsudskiego 92 petro other environment","status":"active","updated_at":"2026-03-08T14:50:24.117Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:24.117Z","email_confidence":"high","email_mx":true,"email_source":"https://tameh.pl/kontakt","parse_date":"2026-07-17T16:18:59.988Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, paliw gazowych, odpadów","en":"Chemical tests of solid fuels, gas fuels, wastes"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych, paliw gazowych","en":"Tests of physical properties of solid fuels, gas fuels"}],"issue":{"no":"18","date":"02.12.2024"},"map_coord":[50.344427,19.263509],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":22,"environment":1},"category_scores":{"petro":21.04,"environment":0.04},"has_zh":true},"methods":[{"_id":"6a5a55f39af9f73f382517d2","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej Zakres: (1,0 – 15,0) % Metoda wagowa","methodology_en":"Transient moisture content Range: (1,0 – 15,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej Zakres: (1,0 – 15,0) % Metoda wagowa","reference":"PN-ISO 589:2006 Metoda A","norm_bases":["PN-ISO 589:2006 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej Zakres: (1,0 – 15,0) % Metoda wagowa PN-ISO 589:2006 Metoda A Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej Zakres: (1,0 – 15,0) % Metoda wagowa PN-ISO 589:2006 Metoda A","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Transient moisture content Range: (1,0 – 15,0) % Gravimetric method PN-ISO 589:2006 Metoda A","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 Metoda A","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d3","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,4 – 11,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,4 – 11,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,4 – 11,0) % Metoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,4 – 11,0) % Metoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,4 – 11,0) % Metoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,4 – 11,0) % Gravimetric method PN-ISO 11722:2009","search_zh":"固体燃料：烟煤 PN-ISO 11722:2009","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d4","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 11,00) % Metoda termograwimetryczna","methodology_en":"Moisture content in the analytical sample Range: (0,40 – 11,00) % Thermogravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 11,00) % Metoda termograwimetryczna","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,40 – 11,00) % Metoda termograwimetryczna PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,40 – 11,00) % Metoda termograwimetryczna PN-G-04560:1998","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Range: (0,40 – 11,00) % Thermogravimetric method PN-G-04560:1998","search_zh":"固体燃料：烟煤 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d5","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 13,0) % Metoda wagowa","methodology_en":"Moisture content in air-dry coal Range: (0,5 – 13,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 13,0) % Metoda wagowa","reference":"PN-ISO 589:2006 Metoda A1 i A2","norm_bases":["PN-ISO 589:2006 Metoda A1 i A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrzno-suchym Zakres: (0,5 – 13,0) % Metoda wagowa PN-ISO 589:2006 Metoda A1 i A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrzno-suchym Zakres: (0,5 – 13,0) % Metoda wagowa PN-ISO 589:2006 Metoda A1 i A2","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Moisture content in air-dry coal Range: (0,5 – 13,0) % Gravimetric method PN-ISO 589:2006 Metoda A1 i A2","search_zh":"固体燃料：烟煤 PN-ISO 589:2006 Metoda A1 i A2","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d6","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 Metoda A","norm_bases":["PN-ISO 589:2006 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 Metoda A Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 Metoda A","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 Metoda A","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 Metoda A","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5a55f39af9f73f382517d7","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (1,0 – 50,0) % Metoda wagowa","methodology_en":"Ash content Range: (1,0 – 50,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,0 – 50,0) % Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (1,0 – 50,0) % Metoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (1,0 – 50,0) % Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (1,0 – 50,0) % Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料：烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d8","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda termograwimetryczna","methodology_en":"Ash content Range: (1,00 – 58,00)% Thermogravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda termograwimetryczna","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu Zakres: (1,00 – 58,00)% Metoda termograwimetryczna PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu Zakres: (1,00 – 58,00)% Metoda termograwimetryczna PN-G-04560:1998","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Ash content Range: (1,00 – 58,00)% Thermogravimetric method PN-G-04560:1998","search_zh":"固体燃料：烟煤 PN-G-04560:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517d9","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego Zakres: (42,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (42,0 – 90,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (42,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego Zakres: (42,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego Zakres: (42,0 – 90,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total carbon content Range: (42,0 – 90,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517da","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,20 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulfur content Range: (0,20 – 2,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,20 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej Zakres: (0,20 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,20 – 2,00) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Total sulfur content Range: (0,20 – 2,00) % High-temperature combustion method with IR detection PN-G-04584:2001","search_zh":"固体燃料：烟煤 PN-G-04584:2001","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517db","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru Zakres: (1,50 – 5,50) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Hydrogen content Range: (1,50 – 5,50) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru Zakres: (1,50 – 5,50) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru Zakres: (1,50 – 5,50) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru Zakres: (1,50 – 5,50) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Hydrogen content Range: (1,50 – 5,50) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料：烟煤 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517dc","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania Zakres: (18 000 – 35 000) kJ/kg Metoda kalorymetryczna","methodology_en":"Gross calorific value Range: (18 000 – 35 000) kJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (18 000 – 35 000) kJ/kg Metoda kalorymetryczna","reference":"PN-ISO 1928:2020-05 ISO 1928:2020-10","norm_bases":["PN-ISO 1928:2020-05 ISO 1928:2020-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania Zakres: (18 000 – 35 000) kJ/kg Metoda kalorymetryczna PN-ISO 1928:2020-05 ISO 1928:2020-10 Paliwa stale: wegiel kamienny Cieplo spalania Zakres: (18 000 – 35 000) kJ/kg Metoda kalorymetryczna PN-ISO 1928:2020-05 ISO 1928:2020-10","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Gross calorific value Range: (18 000 – 35 000) kJ/kg Calorimetric method PN-ISO 1928:2020-05 ISO 1928:2020-10","search_zh":"固体燃料：烟煤 PN-ISO 1928:2020-05 ISO 1928:2020-10","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517dd","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Wartość opałowa (z obliczeń)","methodology_en":"Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: hard coal Net calorific value (calculated)","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5a55f39af9f73f382517de","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Odpady O): kod 100102, 100101, 100180","test_object_en":"Waste O): code 100102, 100101, 100180","methodology":"Zawartość węgla całkowitego Zakres: (2,00 – 50,00) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (2,00 – 50,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (2,00 – 50,00) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 100102, 100101, 100180 Zawartość węgla całkowitego Zakres: (2,00 – 50,00) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady O): kod 100102, 100101, 100180 Zawartosc wegla calkowitego Zakres: (2,00 – 50,00) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 100102, 100101, 100180 Total carbon content Range: (2,00 – 50,00) % High-temperature combustion method with IR detection PN-G-04571:1998"},{"_id":"6a5a55f39af9f73f382517df","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz mieszankowy","test_object_en":"Gaseous fuels: mixed gas","methodology":"Zawartość składników gazowych Zakres: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of gaseous components Range: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość składników gazowych Zakres: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","norm_bases":["PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz mieszankowy Zawartość składników gazowych Zakres: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz mieszankowy Zawartosc skladnikow gazowych Zakres: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: mixed gas Content of gaseous components Range: CH (3,000 – 35,000) % mol/mol 4 CO (2,000 – 40,000) % mol/mol 2 H (1,800 – 50,000) % mol/mol 2 N (2,000 – 50,000) % mol/mol 2 O (0,300 – 2,000) % mol/mol 2 CO (2,000 – 60,000) % mol/mol C H (0,080 – 1,500) % mol/mol 2 6 C H (0,100 – 1,900) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,250) % mol/mol 3 6 C H (0,010 – 0,200) % mol/mol 3 8 Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"},{"_id":"6a5a55f39af9f73f382517e0","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz mieszankowy","test_object_en":"Gaseous fuels: mixed gas","methodology":"Ciepło spalania Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz mieszankowy Ciepło spalania Wartość opałowa (z obliczeń) Paliwa gazowe: gaz mieszankowy Cieplo spalania Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: mixed gas Gross calorific value Net calorific value (calculated)","methodology_zh":"燃烧热 低位发热量（由计算得出）","search_zh":"燃烧热 低位发热量（由计算得出）"},{"_id":"6a5a55f39af9f73f382517e1","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz konwertorowy","test_object_en":"Gaseous fuels: converter gas","methodology":"Zawartość składników gazowych Zakres: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of gaseous components Range: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość składników gazowych Zakres: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","norm_bases":["PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz konwertorowy Zawartość składników gazowych Zakres: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz konwertorowy Zawartosc skladnikow gazowych Zakres: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: converter gas Content of gaseous components Range: CH (0,011 – 0,300) % mol/mol 4 CO (12,000 – 20,000) % mol/mol 2 H (0,200 – 2,700) % mol/mol 2 N (17,000 – 40,000) % mol/mol 2 O (0,400 – 2,000) % mol/mol 2 CO (35,000 – 70,000) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"},{"_id":"6a5a55f39af9f73f382517e2","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz konwertorowy","test_object_en":"Gaseous fuels: converter gas","methodology":"Ciepło spalania Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz konwertorowy Ciepło spalania Wartość opałowa (z obliczeń) Paliwa gazowe: gaz konwertorowy Cieplo spalania Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: converter gas Gross calorific value Net calorific value (calculated)","methodology_zh":"燃烧热 低位发热量（由计算得出）","search_zh":"燃烧热 低位发热量（由计算得出）"},{"_id":"6a5a55f39af9f73f382517e3","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz koksowniczy","test_object_en":"Gaseous fuels: coke oven gas","methodology":"Zawartość składników gazowych Zakres: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of gaseous components Range: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość składników gazowych Zakres: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","norm_bases":["PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz koksowniczy Zawartość składników gazowych Zakres: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz koksowniczy Zawartosc skladnikow gazowych Zakres: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: coke oven gas Content of gaseous components Range: CH (20,000 – 30,000) % mol/mol 4 CO (1,500 – 3,500) % mol/mol 2 H (50,000 – 63,000) % mol/mol 2 N (1,000 – 12,000) % mol/mol 2 O (0,050 – 1,000) % mol/mol 2 CO (5,000 – 10,000) % mol/mol C H (0,400 – 1,500) % mol/mol 2 6 C H (1,500 – 2,500) % mol/mol 2 4 C H (0,020 – 0,200) % mol/mol 2 2 C H (0,020 – 0,200) % mol/mol 3 6 C H (0,010 – 0,150) % mol/mol 3 8 nC H (0,010 – 0,050) % mol/mol 4 10 Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","search_zh":"气体燃料：焦炉煤气 PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：焦炉煤气"},{"_id":"6a5a55f39af9f73f382517e4","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz koksowniczy","test_object_en":"Gaseous fuels: coke oven gas","methodology":"Ciepło spalania Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz koksowniczy Ciepło spalania Wartość opałowa (z obliczeń) Paliwa gazowe: gaz koksowniczy Cieplo spalania Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: coke oven gas Gross calorific value Net calorific value (calculated)","search_zh":"气体燃料：焦炉煤气 燃烧热 低位发热量（由计算得出）","test_object_zh":"气体燃料：焦炉煤气","methodology_zh":"燃烧热 低位发热量（由计算得出）"},{"_id":"6a5a55f39af9f73f382517e5","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz wielkopiecowy","test_object_en":"Gaseous fuels: blast furnace gas","methodology":"Zawartość składników gazowych Zakres: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of gaseous components Range: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość składników gazowych Zakres: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","norm_bases":["PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz wielkopiecowy Zawartość składników gazowych Zakres: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz wielkopiecowy Zawartosc skladnikow gazowych Zakres: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: blast furnace gas Content of gaseous components Range: CH (0,011 – 0,600) % mol/mol 4 CO (12,000 – 25,000) % mol/mol 2 H (0,500 – 8,500) % mol/mol 2 N (25,000 – 60,000) % mol/mol 2 O (0,500 – 2,000) % mol/mol 2 CO (17,000 – 50,000) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"},{"_id":"6a5a55f39af9f73f382517e6","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz wielkopiecowy","test_object_en":"Gaseous fuels: blast furnace gas","methodology":"Ciepło spalania Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz wielkopiecowy Ciepło spalania Wartość opałowa (z obliczeń) Paliwa gazowe: gaz wielkopiecowy Cieplo spalania Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: blast furnace gas Gross calorific value Net calorific value (calculated)","methodology_zh":"燃烧热 低位发热量（由计算得出）","search_zh":"燃烧热 低位发热量（由计算得出）"},{"_id":"6a5a55f39af9f73f382517e7","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Zawartość składników gazowych Zakres: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of gaseous components Range: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość składników gazowych Zakres: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","norm_bases":["PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Zawartość składników gazowych Zakres: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Zawartosc skladnikow gazowych Zakres: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Metoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas Content of gaseous components Range: CH (90,000 – 98,400) % mol/mol 4 nC H (0,050 – 0,180) % mol/mol 4 10 iC H (0,050 – 0,180) % mol/mol 4 10 CO (0,060 – 1,100) % mol/mol 2 N (0,500 – 3,000) % mol/mol 2 C H (0,450 – 6,000) % mol/mol 2 6 C H (0,200 – 1,000) % mol/mol 3 8 nC H (0,010 – 0,080) % mol/mol 5 12 iC H (0,010 – 0,080) % mol/mol 5 12 C6+ (0,007 – 0,070) % mol/mol Gas chromatography with thermal conductivity (GC-TCD) and flame ionization (GC-FID) detection method PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气 PB/02 wyd. 17 z 01.07.2024 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气"},{"_id":"6a5a55f39af9f73f382517e8","lab_id":"69ad52a3de79e566650fb646","country":"PL","accr_number":"AB 1220","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Ciepło spalania Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Wartość opałowa (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Ciepło spalania Wartość opałowa (z obliczeń) Paliwa gazowe: gaz ziemny Cieplo spalania Wartosc opalowa (z obliczen)","categories":["petro"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Gaseous fuels: natural gas Gross calorific value Net calorific value (calculated)","search_zh":"气体燃料：天然气 燃烧热 低位发热量（由计算得出）","test_object_zh":"气体燃料：天然气","methodology_zh":"燃烧热 低位发热量（由计算得出）"}],"has_pdf":true}