{"lab":{"_id":"69ad52a3de79e566650fb644","accr_number":"AB 1219","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADANIA MLEKA, ul. Ludowa 122, 18-200 Wysokie Mazowieckie","categories":["food","microbiology"],"city":"Wysokie Mazowieckie","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"SPÓŁDZIELNIA MLECZARSKA MLEKOVITA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1219.pdf"],"scope_summary":"","search_text":"spółdzielnia mleczarska mlekovita laboratorium badania mleka, ul. ludowa 122, 18-200 wysokie mazowieckie food microbiology pharma other","status":"active","updated_at":"2026-03-08T14:50:24.039Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-22T00:31:43.277Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201219,podmiot.html","parse_date":"2026-08-22T00:31:43.277Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Mikrobiological tests of food"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"}],"issue":{"no":"14","date":"19.08.2026"},"map_coord":[52.91177,22.496762],"map_geo":"nominatim-street","has_en":true,"lab_locations":[{"name":"LABORATORIUM BADANIA MLEKA","address":"ul. Ludowa 122","city":null,"postal":null},{"name":"Punkt zamarzania PN-EN ISO 5764: 2010","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/21/e8096a9999c8a0181f7a132139c1f232/AB%201219.pdf","category_counts":{"food":8,"microbiology":1},"category_scores":{"food":7.11,"microbiology":0.11},"has_zh":true},"methods":[{"_id":"6a88edeffbf98dd0af9b2267","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Ogólna liczba drobnoustrojów","parameters":[{"name":"Zakres","range":"(10 000 – 2 000 000) jtk/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nZakres (10 000 – 2 000 000) jtk/ml\nMetoda cytometrii przepływowej","reference":"PB-01 Wydanie 6 z 29.04.2022 r. W oparciu o instrukcję aparatu typu BactoScan","norm_bases":["PB-01 Wydanie 6 z 29.04.2022 r. W oparciu o instrukcję aparatu typu BactoScan"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Ogólna liczba drobnoustrojów\nZakres (10 000 – 2 000 000) jtk/ml\nMetoda cytometrii przepływowej PB-01 Wydanie 6 z 29.04.2022 r. W oparciu o instrukcję aparatu typu BactoScan Mleko surowe od krow Ogolna liczba drobnoustrojow\nZakres (10 000 – 2 000 000) jtk/ml\nMetoda cytometrii przeplywowej PB-01 Wydanie 6 z 29.04.2022 r. W oparciu o instrukcje aparatu typu BactoScan","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"微生物总数","parameters_zh":[{"name":"范围","range":"(10 000 – 2 000 000) jtk/ml"}],"search_zh":"牛生鲜乳 微生物总数 流式细胞术 乳品检验实验室 范围 PB-01 Wydanie 6 z 29.04.2022 r. W oparciu o instrukcję aparatu typu BactoScan","technique_zh":"流式细胞术","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b2268","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Liczba komórek somatycznych","parameters":[{"name":"Zakres","range":"(1 000 – 3 000 000)"},{"name":"komórek /ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Liczba komórek somatycznych\nZakres:\nZakres (1 000 – 3 000 000)\nkomórek /ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Liczba komórek somatycznych\nZakres:\nZakres (1 000 – 3 000 000)\nkomórek /ml\nMetoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC Mleko surowe od krow Liczba komorek somatycznych\nZakres:\nZakres (1 000 – 3 000 000)\nkomorek /ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"体细胞计数","parameters_zh":[{"name":"范围","range":"(1 000 – 3 000 000)"},{"name":"komórek /ml"}],"search_zh":"牛生鲜乳 体细胞计数 流式细胞术 乳品检验实验室 范围 PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","technique_zh":"流式细胞术","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b2269","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Zawartość białka","parameters":[{"name":"Zakres","range":"(2,00 - 6,00) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość białka\nZakres (2,00 - 6,00) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","norm_bases":["PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Zawartość białka\nZakres (2,00 - 6,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+ Mleko surowe od krow Zawartosc bialka\nZakres (2,00 - 6,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(2,00 - 6,00) %"}],"search_zh":"牛生鲜乳 蛋白质含量 红外光谱法 乳品检验实验室 范围 PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b226a","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(2,00 - 7,50) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (2,00 - 7,50) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","norm_bases":["PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Zawartość tłuszczu\nZakres (2,00 - 7,50) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+ Mleko surowe od krow Zawartosc tluszczu\nZakres (2,00 - 7,50) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(2,00 - 7,50) %"}],"search_zh":"牛生鲜乳 脂肪含量 红外光谱法 乳品检验实验室 范围 PN-ISO 9622: 2015-09 z zastosowaniem aparatu: Milkoscan 7RM Milkoscan FT+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b226b","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Punkt zamarzania","parameters":[{"name":"Zakres","range":"(-0,557 - 0,000)°C"}],"technique":"Metoda krioskopowa","techniques":["Metoda krioskopowa"],"computed":[],"activity":"Punkt zamarzania\nZakres (-0,557 - 0,000)°C\nMetoda krioskopowa","reference":"PN-EN ISO 5764: 2010","norm_bases":["PN-EN ISO 5764: 2010"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Punkt zamarzania\nZakres (-0,557 - 0,000)°C\nMetoda krioskopowa PN-EN ISO 5764: 2010 Mleko surowe od krow Punkt zamarzania\nZakres (-0,557 - 0,000)°C\nMetoda krioskopowa PN-EN ISO 5764: 2010","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(-0,557 - 0,000)°C"}],"search_zh":"牛生鲜乳 冰点 冰点法 乳品检验实验室 范围 PN-EN ISO 5764: 2010","test_object_zh":"牛生鲜乳","technique_zh":"冰点法","methodology_zh":"冰点","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b226c","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Obecność antybiotyków β-laktamowych tetracyklin","parameters":[],"technique":"Metoda receptorowa","techniques":["Metoda receptorowa"],"computed":[],"activity":"Obecność antybiotyków β-laktamowych tetracyklin\nMetoda receptorowa","reference":"PB-02 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Twinsensor BT","norm_bases":["PB-02 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Twinsensor BT"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Obecność antybiotyków β-laktamowych tetracyklin\nMetoda receptorowa PB-02 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Twinsensor BT Mleko surowe od krow Obecnosc antybiotykow β-laktamowych tetracyklin\nMetoda receptorowa PB-02 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Twinsensor BT","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"牛生鲜乳 受体法 乳品检验实验室 PB-02 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Twinsensor BT","technique_zh":"受体法","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b226d","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Obecność antybiotyków i innych substancji hamujących","parameters":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"computed":[],"activity":"Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna","reference":"PB-03 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Delvotest SP NT","norm_bases":["PB-03 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Delvotest SP NT"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna PB-03 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Delvotest SP NT Mleko surowe od krow Obecnosc antybiotykow i innych substancji hamujacych\nMetoda dyfuzyjna PB-03 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Delvotest SP NT","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"抗生素及其他抑菌物质的检出","search_zh":"牛生鲜乳 抗生素及其他抑菌物质的检出 扩散法 乳品检验实验室 PB-03 Wydanie 1 z 02.02.2015 r. Na podstawie instrukcji producenta testu Delvotest SP NT","technique_zh":"扩散法","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"},{"_id":"6a88edeffbf98dd0af9b226e","lab_id":"69ad52a3de79e566650fb644","country":"PL","accr_number":"AB 1219","accr_body":"PCA","test_object":"Mleko surowe od krów","methodology":"Obecność antybiotyków β-laktamowych tetracyklin","parameters":[],"technique":"Metoda receptorowa","techniques":["Metoda receptorowa"],"computed":[],"activity":"Obecność antybiotyków β-laktamowych tetracyklin\nMetoda receptorowa","reference":"PB-06 Wydanie 1 z 21.11.2017 r. Na podstawie instrukcji producenta testu Twinsensor BTKIT020","norm_bases":["PB-06 Wydanie 1 z 21.11.2017 r. Na podstawie instrukcji producenta testu Twinsensor BTKIT020"],"lab_section":"Laboratorium Badania Mleka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe od krów Obecność antybiotyków β-laktamowych tetracyklin\nMetoda receptorowa PB-06 Wydanie 1 z 21.11.2017 r. Na podstawie instrukcji producenta testu Twinsensor BTKIT020 Mleko surowe od krow Obecnosc antybiotykow β-laktamowych tetracyklin\nMetoda receptorowa PB-06 Wydanie 1 z 21.11.2017 r. Na podstawie instrukcji producenta testu Twinsensor BTKIT020","categories":["food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"牛生鲜乳 受体法 乳品检验实验室 PB-06 Wydanie 1 z 21.11.2017 r. Na podstawie instrukcji producenta testu Twinsensor BTKIT020","technique_zh":"受体法","test_object_zh":"牛生鲜乳","lab_section_zh":"乳品检验实验室"}],"has_pdf":true}