{"lab":{"_id":"69ad52a3de79e566650fb63c","accr_number":"AB 1211","country":"PL","accr_body":"PCA","address":"ul. Wybrzeże Stanisława Wyspiańskiego 27, 50-370 Wrocław, KATEDRA DRÓG, MOSTÓW, KOLEI I LOTNISK, LABORATORIUM BADAWCZE, OBIEKTÓW INFRASTRUKTURY TRANSPORTOWEJ, ul. Wybrzeże Stanisława Wyspiańskiego 41","categories":["construction"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"POLITECHNIKA WROCŁAWSKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1211.pdf"],"scope_summary":"","search_text":"politechnika wrocławska ul. wybrzeże stanisława wyspiańskiego 27, 50-370 wrocław, katedra dróg, mostów, kolei i lotnisk, laboratorium badawcze, obiektów infrastruktury transportowej, ul. wybrzeże stanisława wyspiańskiego 41 other construction electronics","status":"active","updated_at":"2026-03-08T14:50:23.760Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:58:29.262Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201211,podmiot.html","parse_date":"2026-08-13T07:58:29.262Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne wyrobów, materiałów i obiektów budowlanych","en":"Mechanical tests of building products, building materials and building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów, materiałów i obiektów budowlanych","en":"Tests of physical properties of building products, building materials and building items"},{"codes":"L/5","pl":"Badania nieniszczące wyrobów, materiałów i obiektów budowlanych","en":"Non-destructive tests of building products, materials and items"}],"issue":{"no":"16","date":"06.07.2026"},"map_coord":[51.107738,17.062543],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Wybrzeże Stanisława Wyspiańskiego 41","city":null,"postal":null},{"name":"Pracownia Drogowa","address":"ul. Wybrzeże Stanisława Wyspiańskiego 41, 50-370 Wrocław","city":"Wrocław","postal":"50-370"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/0f85c2859d2ce76655b2ad13ebda9677/AB%201211.pdf","has_en":true,"category_counts":{"other":15,"construction":14},"category_scores":{"other":7.76,"construction":6.76},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Wybrzeże Stanisława Wyspiańskiego 41","city":null,"postal":null},{"name":"道路实验室","address":"ul. Wybrzeże Stanisława Wyspiańskiego 41, 50-370 Wrocław","city":"Wrocław","postal":"50-370"}]},"methods":[{"_id":"6a7d79250636ba417e41a6fc","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Grunty","methodology":"Wskaźnik nośności (CBR)","parameters":[{"name":"Zakres siły","range":"do 50 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności (CBR)\nZakres siły do 50 kN","reference":"PN-S-02205:1998 załącznik A","norm_bases":["PN-S-02205:1998 załącznik A"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wskaźnik nośności (CBR)\nZakres siły do 50 kN PN-S-02205:1998 załącznik A Grunty Wskaznik nosnosci (CBR)\nZakres sily do 50 kN PN-S-02205:1998 zalacznik A","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Bearing ratio (CBR)","parameters_en":[{"name":"Force range","range":"do 50 kN"}],"search_en":"Ground Bearing ratio (CBR) Road Laboratory Force range PN-S-02205:1998 załącznik A","test_object_en":"Ground","parameters_zh":[{"name":"力值范围","range":"do 50 kN"}],"search_zh":"土体 道路实验室 力值范围 PN-S-02205:1998 załącznik A","test_object_zh":"土体","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a6fd","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Grunty","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,075 − 63) mm"}],"technique":"Metoda: przesiewania","techniques":["Metoda: przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0,075 − 63) mm\nMetoda: przesiewania","reference":"PN-88/B-04481 p. 4.1","norm_bases":["PN-88/B-04481 p. 4.1"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Skład ziarnowy\nZakres (0,075 − 63) mm\nMetoda: przesiewania PN-88/B-04481 p. 4.1 Grunty Sklad ziarnowy\nZakres (0,075 − 63) mm\nMetoda: przesiewania PN-88/B-04481 p. 4.1","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,075 − 63) mm"}],"search_en":"Ground Particle size distribution Method: sieving Road Laboratory Range PN-88/B-04481 p. 4.1","technique_en":"Method: sieving","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,075 − 63) mm"}],"search_zh":"土体 粒度分布 道路实验室 范围 PN-88/B-04481 p. 4.1","test_object_zh":"土体","methodology_zh":"粒度分布","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a6fe","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna","parameters":[{"name":"Zakres","range":"(3 - 40) %,"},{"name":"Maksymalna gęstość objętościowa szkieletu gruntowego"},{"name":"Zakres","range":"(1,2 – 2,5) g/cm3"}],"technique":"Metoda: Proctora","techniques":["Metoda: Proctora"],"computed":[],"activity":"Wilgotność optymalna\nZakres:\nZakres (3 - 40) %,\nMaksymalna gęstość objętościowa szkieletu gruntowego\nZakres (1,2 – 2,5) g/cm3\nMetoda: Proctora","reference":"PN-88/B-04481 p. 8","norm_bases":["PN-88/B-04481 p. 8"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna\nZakres:\nZakres (3 - 40) %,\nMaksymalna gęstość objętościowa szkieletu gruntowego\nZakres (1,2 – 2,5) g/cm3\nMetoda: Proctora PN-88/B-04481 p. 8 Grunty Wilgotnosc optymalna\nZakres:\nZakres (3 - 40) %,\nMaksymalna gestosc objetosciowa szkieletu gruntowego\nZakres (1,2 – 2,5) g/cm3\nMetoda: Proctora PN-88/B-04481 p. 8","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Optimum moisture content","parameters_en":[{"name":"Range","range":"(3 - 40) %,"},{"name":"Maximum dry density of soil"},{"name":"Range","range":"(1,2 – 2,5) g/cm3"}],"search_en":"Ground Optimum moisture content Method: Proctor Road Laboratory Range Maximum dry density of soil Range PN-88/B-04481 p. 8","technique_en":"Method: Proctor","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(3 - 40) %,"},{"name":"土骨架最大干密度"},{"name":"范围","range":"(1,2 – 2,5) g/cm3"}],"search_zh":"土体 最佳含水率 道路实验室 范围 土骨架最大干密度 范围 PN-88/B-04481 p. 8","test_object_zh":"土体","lab_section_zh":"道路实验室","methodology_zh":"最佳含水率"},{"_id":"6a7d79250636ba417e41a6ff","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Podłoże","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres obciążenia","range":"(0,00 – 0,35) MPa"}],"technique":"Metoda: obciążeń płytą VSS","techniques":["Metoda: obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres obciążenia (0,00 – 0,35) MPa\nMetoda: obciążeń płytą VSS","reference":"PN-S-02205:1998 zał. B","norm_bases":["PN-S-02205:1998 zał. B"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Moduł odkształcenia\nZakres obciążenia (0,00 – 0,35) MPa\nMetoda: obciążeń płytą VSS PN-S-02205:1998 zał. B Podloze Modul odksztalcenia\nZakres obciazenia (0,00 – 0,35) MPa\nMetoda: obciazen plyta VSS PN-S-02205:1998 zal. B","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Deformation modulus","parameters_en":[{"name":"Load range","range":"(0,00 – 0,35) MPa"}],"search_en":"Growing medium Deformation modulus Method: VSS plate load test Road Laboratory Load range PN-S-02205:1998 zał. B","technique_en":"Method: VSS plate load test","test_object_en":"Growing medium","search_zh":"栽培基质 变形模量 方法：VSS 平板载荷法 道路实验室 载荷范围 PN-S-02205:1998 zał. B","test_object_zh":"栽培基质","lab_section_zh":"道路实验室","methodology_zh":"变形模量","parameters_zh":[{"name":"载荷范围","range":"(0,00 – 0,35) MPa"}],"technique_zh":"方法：VSS 平板载荷法"},{"_id":"6a7d79250636ba417e41a700","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Kruszywa","methodology":"Nasiąkliwość","parameters":[{"name":"Zakres","range":"(0,063 − 31,5) mm"}],"technique":"Metoda: piknometryczna","techniques":["Metoda: piknometryczna"],"computed":[],"activity":"Nasiąkliwość\nZakres (0,063 − 31,5) mm\nMetoda: piknometryczna","reference":"PN-EN 1097-6 :2022 p. 8, p. 9","norm_bases":["PN-EN 1097-6 :2022 p. 8, p. 9"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Nasiąkliwość\nZakres (0,063 − 31,5) mm\nMetoda: piknometryczna PN-EN 1097-6 :2022 p. 8, p. 9 Kruszywa Nasiakliwosc\nZakres (0,063 − 31,5) mm\nMetoda: piknometryczna PN-EN 1097-6 :2022 p. 8, p. 9","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Water absorption","parameters_en":[{"name":"Range","range":"(0,063 − 31,5) mm"}],"search_en":"Aggregates Water absorption Method: pycnometric Road Laboratory Range PN-EN 1097-6 :2022 p. 8, p. 9","technique_en":"Method: pycnometric","test_object_en":"Aggregates","methodology_zh":"吸水率","parameters_zh":[{"name":"范围","range":"(0,063 − 31,5) mm"}],"search_zh":"骨料 吸水率 方法：比重瓶法 道路实验室 范围 PN-EN 1097-6 :2022 p. 8, p. 9","test_object_zh":"骨料","lab_section_zh":"道路实验室","technique_zh":"方法：比重瓶法"},{"_id":"6a7d79250636ba417e41a701","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność","parameters":[{"name":"Zakres","range":"(-20) ° C − (+20) °C"}],"technique":"Metoda: zamrażania-rozmrażania w wodzie","techniques":["Metoda: zamrażania-rozmrażania w wodzie"],"computed":[],"activity":"Mrozoodporność\nZakres (-20) ° C − (+20) °C\nMetoda: zamrażania-rozmrażania w wodzie","reference":"PN-EN 1367-1:2007","norm_bases":["PN-EN 1367-1:2007"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność\nZakres (-20) ° C − (+20) °C\nMetoda: zamrażania-rozmrażania w wodzie PN-EN 1367-1:2007 Kruszywa Mrozoodpornosc\nZakres (-20) ° C − (+20) °C\nMetoda: zamrazania-rozmrazania w wodzie PN-EN 1367-1:2007","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Frost resistance","parameters_en":[{"name":"Range","range":"(-20) ° C − (+20) °C"}],"search_en":"Aggregates Frost resistance Method: freeze-thaw in water Road Laboratory Range PN-EN 1367-1:2007","technique_en":"Method: freeze-thaw in water","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(-20) ° C − (+20) °C"}],"search_zh":"骨料 抗冻性 道路实验室 范围 PN-EN 1367-1:2007","test_object_zh":"骨料","lab_section_zh":"道路实验室","methodology_zh":"抗冻性"},{"_id":"6a7d79250636ba417e41a702","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[{"name":"Zakres","range":"(4 − 63) mm"}],"technique":"Metoda: Los Angeles","techniques":["Metoda: Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nZakres (4 − 63) mm\nMetoda: Los Angeles","reference":"PN-EN 1097-2:2020 p. 5","norm_bases":["PN-EN 1097-2:2020 p. 5"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nZakres (4 − 63) mm\nMetoda: Los Angeles PN-EN 1097-2:2020 p. 5 Kruszywa Odpornosc na rozdrabnianie\nZakres (4 − 63) mm\nMetoda: Los Angeles PN-EN 1097-2:2020 p. 5","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Resistance to fragmentation","parameters_en":[{"name":"Range","range":"(4 − 63) mm"}],"search_en":"Aggregates Resistance to fragmentation Method: Los Angeles Road Laboratory Range PN-EN 1097-2:2020 p. 5","technique_en":"Method: Los Angeles","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(4 − 63) mm"}],"search_zh":"骨料 抗破碎性 方法：洛杉矶法 道路实验室 范围 PN-EN 1097-2:2020 p. 5","test_object_zh":"骨料","lab_section_zh":"道路实验室","methodology_zh":"抗破碎性","technique_zh":"方法：洛杉矶法"},{"_id":"6a7d79250636ba417e41a703","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 − 63) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 − 63) mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 − 63) mm PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 − 63) mm PN-EN 933-1:2012","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 − 63) mm"}],"search_en":"Aggregates Particle size distribution Road Laboratory Range PN-EN 933-1:2012","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,063 − 63) mm"}],"search_zh":"骨料 粒度分布 道路实验室 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a704","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Asfalty i lepiszcza asfaltowe","methodology":"Penetracja igłą","parameters":[{"name":"Zakres","range":"do 25 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Penetracja igłą\nZakres do 25 mm","reference":"PN-EN 1426:2015-08","norm_bases":["PN-EN 1426:2015-08"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Asfalty i lepiszcza asfaltowe Penetracja igłą\nZakres do 25 mm PN-EN 1426:2015-08 Asfalty i lepiszcza asfaltowe Penetracja igla\nZakres do 25 mm PN-EN 1426:2015-08","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Needle penetration","parameters_en":[{"name":"Range","range":"do 25 mm"}],"search_en":"Bitumens and bituminous binders Needle penetration Road Laboratory Range PN-EN 1426:2015-08","test_object_en":"Bitumens and bituminous binders","parameters_zh":[{"name":"范围","range":"do 25 mm"}],"search_zh":"沥青与沥青胶结料 针入度 道路实验室 范围 PN-EN 1426:2015-08","test_object_zh":"沥青与沥青胶结料","lab_section_zh":"道路实验室","methodology_zh":"针入度"},{"_id":"6a7d79250636ba417e41a705","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Asfalty i lepiszcza asfaltowe","methodology":"Temperatura mięknienia","parameters":[{"name":"Zakres","range":"(20-150) °C"}],"technique":"Metoda: pierścienia i kuli","techniques":["Metoda: pierścienia i kuli"],"computed":[],"activity":"Temperatura mięknienia\nZakres (20-150) °C\nMetoda: pierścienia i kuli","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Asfalty i lepiszcza asfaltowe Temperatura mięknienia\nZakres (20-150) °C\nMetoda: pierścienia i kuli PN-EN 1427:2015-08 Asfalty i lepiszcza asfaltowe Temperatura mieknienia\nZakres (20-150) °C\nMetoda: pierscienia i kuli PN-EN 1427:2015-08","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Softening point","parameters_en":[{"name":"Range","range":"(20-150) °C"}],"search_en":"Bitumens and bituminous binders Softening point Method: ring and ball Road Laboratory Range PN-EN 1427:2015-08","technique_en":"Method: ring and ball","test_object_en":"Bitumens and bituminous binders","parameters_zh":[{"name":"范围","range":"(20-150) °C"}],"search_zh":"沥青与沥青胶结料 软化点温度 道路实验室 范围 PN-EN 1427:2015-08","test_object_zh":"沥青与沥青胶结料","lab_section_zh":"道路实验室","methodology_zh":"软化点温度"},{"_id":"6a7d79250636ba417e41a706","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Ugięcia","parameters":[{"name":"Zakres","range":"do 2000 μm"},{"name":"FWD"}],"technique":"Metoda: ugięciomierza udarowego","techniques":["Metoda: ugięciomierza udarowego"],"computed":[],"activity":"Ugięcia\nZakres:\nZakres do 2000 μm\nFWD\nMetoda: ugięciomierza udarowego","reference":"PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r.","norm_bases":["PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r."],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Ugięcia\nZakres:\nZakres do 2000 μm\nFWD\nMetoda: ugięciomierza udarowego PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r. Nawierzchnie drogowe Ugiecia\nZakres:\nZakres do 2000 μm\nFWD\nMetoda: ugieciomierza udarowego PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r.","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Deflections","parameters_en":[{"name":"Range","range":"do 2000 μm"},{"name":"FWD"}],"search_en":"Road pavements Deflections Method: impact deflectometer Road Laboratory Range FWD PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r.","technique_en":"Method: impact deflectometer","test_object_en":"Road pavements","parameters_zh":[{"name":"范围","range":"do 2000 μm"},{"name":"FWD"}],"search_zh":"路面 道路实验室 范围 PT-LBOIT-01-4 Wydanie 2 z dnia 15.02.2021 r.","test_object_zh":"路面","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a707","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Równość poprzeczna","parameters":[{"name":"Zakres","range":"(1 − 20) mm"}],"technique":"Metoda: za pomocą łaty i klina","techniques":["Metoda: za pomocą łaty i klina"],"computed":[],"activity":"Równość poprzeczna\nZakres (1 − 20) mm\nMetoda: za pomocą łaty i klina","reference":"PN-EN 13036-7:2004","norm_bases":["PN-EN 13036-7:2004"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Równość poprzeczna\nZakres (1 − 20) mm\nMetoda: za pomocą łaty i klina PN-EN 13036-7:2004 Nawierzchnie drogowe Rownosc poprzeczna\nZakres (1 − 20) mm\nMetoda: za pomoca laty i klina PN-EN 13036-7:2004","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Transverse evenness","parameters_en":[{"name":"Range","range":"(1 − 20) mm"}],"search_en":"Road pavements Transverse evenness Method: using a straightedge and wedge Road Laboratory Range PN-EN 13036-7:2004","technique_en":"Method: using a straightedge and wedge","test_object_en":"Road pavements","parameters_zh":[{"name":"范围","range":"(1 − 20) mm"}],"search_zh":"路面 道路实验室 范围 PN-EN 13036-7:2004","test_object_zh":"路面","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a708","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Równość podłużna","parameters":[{"name":"Zakres","range":"(1 − 20) mm"}],"technique":"Metoda: za pomocą łaty i klina","techniques":["Metoda: za pomocą łaty i klina"],"computed":[],"activity":"Równość podłużna\nZakres (1 − 20) mm\nMetoda: za pomocą łaty i klina","reference":"PN-EN 13036-7:2004","norm_bases":["PN-EN 13036-7:2004"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Równość podłużna\nZakres (1 − 20) mm\nMetoda: za pomocą łaty i klina PN-EN 13036-7:2004 Nawierzchnie drogowe Rownosc podluzna\nZakres (1 − 20) mm\nMetoda: za pomoca laty i klina PN-EN 13036-7:2004","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Longitudinal evenness","parameters_en":[{"name":"Range","range":"(1 − 20) mm"}],"search_en":"Road pavements Longitudinal evenness Method: using a straightedge and wedge Road Laboratory Range PN-EN 13036-7:2004","technique_en":"Method: using a straightedge and wedge","test_object_en":"Road pavements","parameters_zh":[{"name":"范围","range":"(1 − 20) mm"}],"search_zh":"路面 道路实验室 范围 PN-EN 13036-7:2004","test_object_zh":"路面","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a709","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Współczynnik tarcia","parameters":[{"name":"Zakres docisku kół","range":"(60 – 100) kg"}],"technique":"Metoda: za pomocą urządzenia TWO","techniques":["Metoda: za pomocą urządzenia TWO"],"computed":[],"activity":"Współczynnik tarcia\nZakres docisku kół (60 – 100) kg\nMetoda: za pomocą urządzenia TWO","reference":"PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r.","norm_bases":["PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r."],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Współczynnik tarcia\nZakres docisku kół (60 – 100) kg\nMetoda: za pomocą urządzenia TWO PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r. Nawierzchnie drogowe Wspolczynnik tarcia\nZakres docisku kol (60 – 100) kg\nMetoda: za pomoca urzadzenia TWO PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r.","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Friction coefficient","parameters_en":[{"name":"Range of wheel pressure","range":"(60 – 100) kg"}],"search_en":"Road pavements Friction coefficient Method: using the TWO device Road Laboratory Range of wheel pressure PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r.","technique_en":"Method: using the TWO device","test_object_en":"Road pavements","search_zh":"路面 摩擦系数 道路实验室 PT-LBOIT-01-8 Wydanie 1 z dnia 10.01.2024 r.","test_object_zh":"路面","lab_section_zh":"道路实验室","methodology_zh":"摩擦系数"},{"_id":"6a7d79250636ba417e41a70a","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia","parameters":[{"name":"Zakres obciążenia","range":"(0,00 – 0,45) MPa"}],"technique":"Metoda: obciążeń płytą VSS","techniques":["Metoda: obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia\nZakres obciążenia (0,00 – 0,45) MPa\nMetoda: obciążeń płytą VSS","reference":"PN-S-02205:1998 zał. B","norm_bases":["PN-S-02205:1998 zał. B"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres obciążenia (0,00 – 0,45) MPa\nMetoda: obciążeń płytą VSS PN-S-02205:1998 zał. B Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres obciazenia (0,00 – 0,45) MPa\nMetoda: obciazen plyta VSS PN-S-02205:1998 zal. B","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Deformation modulus","parameters_en":[{"name":"Load range","range":"(0,00 – 0,45) MPa"}],"search_en":"Pavement structural layers Deformation modulus Method: VSS plate load test Road Laboratory Load range PN-S-02205:1998 zał. B","technique_en":"Method: VSS plate load test","test_object_en":"Pavement structural layers","search_zh":"路面结构层 变形模量 方法：VSS 平板载荷法 道路实验室 载荷范围 PN-S-02205:1998 zał. B","test_object_zh":"路面结构层","lab_section_zh":"道路实验室","methodology_zh":"变形模量","parameters_zh":[{"name":"载荷范围","range":"(0,00 – 0,45) MPa"}],"technique_zh":"方法：VSS 平板载荷法"},{"_id":"6a7d79250636ba417e41a70b","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Water absorption","search_en":"Concrete Water absorption Road Laboratory PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 道路实验室 PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a70c","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Beton","methodology":"Mrozoodporność","parameters":[{"name":"Zakres","range":"(-20) °C − (+20) °C"}],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Mrozoodporność\nZakres (-20) °C − (+20) °C\nMetoda zwykła","reference":"PN-B-06265:2022, zał. N","norm_bases":["PN-B-06265:2022, zał. N"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Mrozoodporność\nZakres (-20) °C − (+20) °C\nMetoda zwykła PN-B-06265:2022, zał. N Beton Mrozoodpornosc\nZakres (-20) °C − (+20) °C\nMetoda zwykla PN-B-06265:2022, zal. N","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Frost resistance","parameters_en":[{"name":"Range","range":"(-20) °C − (+20) °C"}],"search_en":"Concrete Frost resistance Ordinary method Road Laboratory Range PN-B-06265:2022, zał. N","technique_en":"Ordinary method","test_object_en":"Concrete","parameters_zh":[{"name":"范围","range":"(-20) °C − (+20) °C"}],"search_zh":"混凝土 抗冻性 常规法 道路实验室 范围 PN-B-06265:2022, zał. N","test_object_zh":"混凝土","lab_section_zh":"道路实验室","methodology_zh":"抗冻性","technique_zh":"常规法"},{"_id":"6a7d79250636ba417e41a70d","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(100 − 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (100 − 3000) kN","reference":"PN-EN 12390-3:2019","norm_bases":["PN-EN 12390-3:2019"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (100 − 3000) kN PN-EN 12390-3:2019 Beton Wytrzymalosc na sciskanie\nZakres sily (100 − 3000) kN PN-EN 12390-3:2019","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(100 − 3000) kN"}],"search_en":"Concrete Compressive strength Road Laboratory Force range PN-EN 12390-3:2019","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(100 − 3000) kN"}],"search_zh":"混凝土 抗压强度 道路实验室 力值范围 PN-EN 12390-3:2019","test_object_zh":"混凝土","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a70e","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres siły","range":"(10 − 500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (10 − 500) kN","reference":"PN-EN 12390-6:2024","norm_bases":["PN-EN 12390-6:2024"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (10 − 500) kN PN-EN 12390-6:2024 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres sily (10 − 500) kN PN-EN 12390-6:2024","categories":["construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Force range","range":"(10 − 500) kN"}],"search_en":"Concrete Splitting tensile strength Road Laboratory Force range PN-EN 12390-6:2024","test_object_en":"Concrete","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"力值范围","range":"(10 − 500) kN"}],"search_zh":"混凝土 劈裂抗拉强度 道路实验室 力值范围 PN-EN 12390-6:2024","test_object_zh":"混凝土","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a70f","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres siły","range":"(10 − 100) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres siły (10 − 100) kN","reference":"PN-EN 12390-5:2019","norm_bases":["PN-EN 12390-5:2019"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres siły (10 − 100) kN PN-EN 12390-5:2019 Beton Wytrzymalosc na zginanie\nZakres sily (10 − 100) kN PN-EN 12390-5:2019","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Flexural strength","parameters_en":[{"name":"Force range","range":"(10 − 100) kN"}],"search_en":"Concrete Flexural strength Road Laboratory Force range PN-EN 12390-5:2019","test_object_en":"Concrete","parameters_zh":[{"name":"力值范围","range":"(10 − 100) kN"}],"search_zh":"混凝土 抗弯强度 道路实验室 力值范围 PN-EN 12390-5:2019","test_object_zh":"混凝土","methodology_zh":"抗弯强度","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a710","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Grunty stabilizowane cementem","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(3 − 50) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (3 − 50) kN","reference":"PN-EN 13286-41:2022","norm_bases":["PN-EN 13286-41:2022"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty stabilizowane cementem Wytrzymałość na ściskanie\nZakres siły (3 − 50) kN PN-EN 13286-41:2022 Grunty stabilizowane cementem Wytrzymalosc na sciskanie\nZakres sily (3 − 50) kN PN-EN 13286-41:2022","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(3 − 50) kN"}],"search_en":"Cement-stabilised soils Compressive strength Road Laboratory Force range PN-EN 13286-41:2022","test_object_en":"Cement-stabilised soils","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(3 − 50) kN"}],"search_zh":"抗压强度 道路实验室 力值范围 PN-EN 13286-41:2022","lab_section_zh":"道路实验室"},{"_id":"6a7d79250636ba417e41a711","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Grunty stabilizowane cementem","methodology":"Mrozoodporność","parameters":[{"name":"Zakres","range":"(-23) °C − (+20) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność\nZakres (-23) °C − (+20) °C","reference":"PN-S-96012:1997","norm_bases":["PN-S-96012:1997"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty stabilizowane cementem Mrozoodporność\nZakres (-23) °C − (+20) °C PN-S-96012:1997 Grunty stabilizowane cementem Mrozoodpornosc\nZakres (-23) °C − (+20) °C PN-S-96012:1997","categories":["construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Frost resistance","parameters_en":[{"name":"Range","range":"(-23) °C − (+20) °C"}],"search_en":"Cement-stabilised soils Frost resistance Road Laboratory Range PN-S-96012:1997","test_object_en":"Cement-stabilised soils","parameters_zh":[{"name":"范围","range":"(-23) °C − (+20) °C"}],"search_zh":"抗冻性 道路实验室 范围 PN-S-96012:1997","lab_section_zh":"道路实验室","methodology_zh":"抗冻性"},{"_id":"6a7d79250636ba417e41a712","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda: A i B","techniques":["Metoda: A i B"],"computed":[],"activity":"Gęstość objętościowa\nMetoda: A i B","reference":"PN-EN 12697-6:2020","norm_bases":["PN-EN 12697-6:2020"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Gęstość objętościowa\nMetoda: A i B PN-EN 12697-6:2020 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Gestosc objetosciowa\nMetoda: A i B PN-EN 12697-6:2020","categories":["construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Bulk density","search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Bulk density Method: A and B Road Laboratory PN-EN 12697-6:2020","technique_en":"Method: A and B","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","methodology_zh":"堆积密度","search_zh":"沥青混合料（水泥-乳化沥青混合料） 堆积密度 道路实验室 PN-EN 12697-6:2020","lab_section_zh":"道路实验室","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）"},{"_id":"6a7d79250636ba417e41a713","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[{"name":"Zakres","range":"(0 − 15) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego\nZakres (0 − 15) %","reference":"PN-EN 12697-1:2020","norm_bases":["PN-EN 12697-1:2020"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Zawartość lepiszcza rozpuszczalnego\nZakres (0 − 15) % PN-EN 12697-1:2020 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Zawartosc lepiszcza rozpuszczalnego\nZakres (0 − 15) % PN-EN 12697-1:2020","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Soluble binder content","parameters_en":[{"name":"Range","range":"(0 − 15) %"}],"search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Soluble binder content Road Laboratory Range PN-EN 12697-1:2020","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","parameters_zh":[{"name":"范围","range":"(0 − 15) %"}],"search_zh":"沥青混合料（水泥-乳化沥青混合料） 可溶性胶结料含量 道路实验室 范围 PN-EN 12697-1:2020","lab_section_zh":"道路实验室","methodology_zh":"可溶性胶结料含量","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）"},{"_id":"6a7d79250636ba417e41a714","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0,063 − 63) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Skład ziarnowy\nZakres (0,063 − 63) mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Skład ziarnowy\nZakres (0,063 − 63) mm PN-EN 933-1:2012 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Sklad ziarnowy\nZakres (0,063 − 63) mm PN-EN 933-1:2012","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 − 63) mm"}],"search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Particle size distribution Road Laboratory Range PN-EN 933-1:2012","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","parameters_zh":[{"name":"范围","range":"(0,063 − 63) mm"}],"search_zh":"沥青混合料（水泥-乳化沥青混合料） 粒度分布 道路实验室 范围 PN-EN 933-1:2012","methodology_zh":"粒度分布","lab_section_zh":"道路实验室","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）"},{"_id":"6a7d79250636ba417e41a715","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Sztywność Zakres siły: do 4 kN","parameters":[{"name":"Zakres przemieszczenia","range":"do 10 mm"}],"technique":"Metoda: IT-CY","techniques":["Metoda: IT-CY"],"computed":[],"activity":"Sztywność Zakres siły: do 4 kN\nZakres przemieszczenia do 10 mm\nMetoda: IT-CY","reference":"PN-EN 12697-26+A1:2023-03","norm_bases":["PN-EN 12697-26+A1:2023-03"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Sztywność Zakres siły: do 4 kN\nZakres przemieszczenia do 10 mm\nMetoda: IT-CY PN-EN 12697-26+A1:2023-03 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Sztywnosc Zakres sily: do 4 kN\nZakres przemieszczenia do 10 mm\nMetoda: IT-CY PN-EN 12697-26+A1:2023-03","categories":["construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Stiffness Force range: up to 4 kN","parameters_en":[{"name":"Displacement range","range":"do 10 mm"}],"search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Stiffness Force range: up to 4 kN Method: IT-CY Road Laboratory Displacement range PN-EN 12697-26+A1:2023-03","technique_en":"Method: IT-CY","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","lab_section_zh":"道路实验室","search_zh":"沥青混合料（水泥-乳化沥青混合料） 道路实验室 位移范围 PN-EN 12697-26+A1:2023-03","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）","parameters_zh":[{"name":"位移范围","range":"do 10 mm"}]},{"_id":"6a7d79250636ba417e41a716","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Sztywność, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm","parameters":[],"technique":"Metoda: belka 4 punktowa","techniques":["Metoda: belka 4 punktowa"],"computed":[],"activity":"Sztywność, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa","reference":"PN-EN 12697-26+A1:2023-03","norm_bases":["PN-EN 12697-26+A1:2023-03"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Sztywność, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa PN-EN 12697-26+A1:2023-03 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Sztywnosc, Zakres sily: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa PN-EN 12697-26+A1:2023-03","categories":["construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Stiffness, Force range: up to 5 kN, Displacement range: up to 2 mm","search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Stiffness, Force range: up to 5 kN, Displacement range: up to 2 mm Method: 4-point beam Road Laboratory PN-EN 12697-26+A1:2023-03","technique_en":"Method: 4-point beam","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","lab_section_zh":"道路实验室","search_zh":"沥青混合料（水泥-乳化沥青混合料） 道路实验室 PN-EN 12697-26+A1:2023-03","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）"},{"_id":"6a7d79250636ba417e41a717","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Odporność na deformacje trwałe","parameters":[{"name":"Zakres","range":"40 mm"}],"technique":"Metoda: koleinowanie metodą B (w powietrzu), mały aparat","techniques":["Metoda: koleinowanie metodą B (w powietrzu), mały aparat"],"computed":[],"activity":"Odporność na deformacje trwałe\nZakres 40 mm\nMetoda: koleinowanie metodą B (w powietrzu), mały aparat","reference":"PN-EN 12697-22+A1:2024-05","norm_bases":["PN-EN 12697-22+A1:2024-05"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Odporność na deformacje trwałe\nZakres 40 mm\nMetoda: koleinowanie metodą B (w powietrzu), mały aparat PN-EN 12697-22+A1:2024-05 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Odpornosc na deformacje trwale\nZakres 40 mm\nMetoda: koleinowanie metoda B (w powietrzu), maly aparat PN-EN 12697-22+A1:2024-05","categories":["construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Resistance to permanent deformation","parameters_en":[{"name":"Range","range":"40 mm"}],"search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Resistance to permanent deformation Method: wheel tracking by method B (in air), small device Road Laboratory Range PN-EN 12697-22+A1:2024-05","technique_en":"Method: wheel tracking by method B (in air), small device","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","parameters_zh":[{"name":"范围","range":"40 mm"}],"search_zh":"沥青混合料（水泥-乳化沥青混合料） 耐永久变形性 方法：车辙试验 B 法（空气中），小型试验仪 道路实验室 范围 PN-EN 12697-22+A1:2024-05","lab_section_zh":"道路实验室","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）","technique_zh":"方法：车辙试验 B 法（空气中），小型试验仪","methodology_zh":"耐永久变形性"},{"_id":"6a7d79250636ba417e41a718","lab_id":"69ad52a3de79e566650fb63c","country":"PL","accr_number":"AB 1211","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne)","methodology":"Odporność na zmęczenie, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm","parameters":[],"technique":"Metoda: belka 4 punktowa","techniques":["Metoda: belka 4 punktowa"],"computed":[],"activity":"Odporność na zmęczenie, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa","reference":"PN-EN 12697-24:2018-08","norm_bases":["PN-EN 12697-24:2018-08"],"lab_section":"Pracownia Drogowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Odporność na zmęczenie, Zakres siły: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa PN-EN 12697-24:2018-08 Mieszanki mineralno-asfaltowe mma (mieszanki cementowo- emulsyjne) Odpornosc na zmeczenie, Zakres sily: do 5 kN, Zakres przemieszczenia: do 2 mm\nMetoda: belka 4 punktowa PN-EN 12697-24:2018-08","categories":["construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Road Laboratory","methodology_en":"Fatigue resistance, Force range: up to 5 kN, Displacement range: up to 2 mm","search_en":"Bituminous mixtures mma (cement-emulsion mixtures) Fatigue resistance, Force range: up to 5 kN, Displacement range: up to 2 mm Method: 4-point beam Road Laboratory PN-EN 12697-24:2018-08","technique_en":"Method: 4-point beam","test_object_en":"Bituminous mixtures mma (cement-emulsion mixtures)","lab_section_zh":"道路实验室","search_zh":"沥青混合料（水泥-乳化沥青混合料） 道路实验室 PN-EN 12697-24:2018-08","test_object_zh":"沥青混合料（水泥-乳化沥青混合料）"}],"has_pdf":true}