{"lab":{"_id":"69ad52a3de79e566650fb129","accr_number":"AB 121","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ URZĄDZEŃ TELEKOMUNIKACYJNYCH (LBUT), ul. Szachowa 1, 04-894 Warszawa","categories":["electronics","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":76,"name":"INSTYTUT ŁĄCZNOŚCI - PAŃSTWOWY INSTYTUT BADAWCZY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_121.pdf"],"scope_summary":"","search_text":"instytut łączności - państwowy instytut badawczy laboratorium badań urządzeń telekomunikacyjnych (lbut), ul. szachowa 1, 04-894 warszawa other environment metrology pharma electronics materials water construction","status":"active","updated_at":"2026-03-08T14:50:23.700Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:23.700Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20121,podmiot.html","parse_date":"2026-07-17T16:18:59.741Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"E/6; E/14; E/53; E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical products and equipment, medical equipment, telecommunication and electronic products and equipment"},{"codes":"F/6; F/14; F/53; F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment, medical equipment, telecommunication and electronic products and equipment"},{"codes":"G/6; G/14; G/53; G/54","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests concerning environmental engineering (environmental and climatic) of electrical products and equipment, medical equipment, telecommunication and electronic products and equipment"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne)- środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne), środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful factors – electromagnetic field), general environment (physical factors - electromagnetic field)"},{"codes":"N/6, N/53; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical, products and equipment, telecommunication and electronic products and equipment"}],"issue":{"no":"26","date":"16.01.2026"},"map_coord":[52.172549,21.195188],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":51,"electronics":17,"environment":6,"construction":3,"materials":2},"category_scores":{"other":32.92,"electronics":3.66,"environment":0.46,"construction":0.11,"materials":0.05},"has_zh":true},"methods":[{"_id":"6a5a55f39af9f73f382516fd","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Moc nadajnika (sygnał doprowadzony)","methodology_en":"Transmitter power (conducted signal)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc nadajnika (sygnał doprowadzony)","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Moc nadajnika (sygnał doprowadzony) Normy Urzadzenia radiowe E Moc nadajnika (sygnal doprowadzony) Normy","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter power (conducted signal) Normy","search_zh":"无线电设备 E Normy","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f382516fe","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Moc promieniowana nadajnika","methodology_en":"Radiated power of the transmitter","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc promieniowana nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Moc promieniowana nadajnika Urzadzenia radiowe E Moc promieniowana nadajnika","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Radiated power of the transmitter","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f382516ff","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Pole magnetyczne nadajnika","methodology_en":"Transmitter magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pole magnetyczne nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Pole magnetyczne nadajnika Urzadzenia radiowe E Pole magnetyczne nadajnika","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter magnetic field","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251700","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Pole elektryczne nadajnika","methodology_en":"Transmitter electric field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pole elektryczne nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Pole elektryczne nadajnika Urzadzenia radiowe E Pole elektryczne nadajnika","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter electric field","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251701","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Widmowa gęstość mocy","methodology_en":"Power spectral density","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Widmowa gęstość mocy","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Widmowa gęstość mocy Urzadzenia radiowe E Widmowa gestosc mocy","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Power spectral density","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251702","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Odchyłka częstotliwości","methodology_en":"Frequency deviation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchyłka częstotliwości","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Odchyłka częstotliwości Urzadzenia radiowe E Odchylka czestotliwosci","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Frequency deviation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251703","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Dewiacja częstotliwości","methodology_en":"Frequency deviation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dewiacja częstotliwości","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Dewiacja częstotliwości Urzadzenia radiowe E Dewiacja czestotliwosci","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Frequency deviation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251704","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Moc w kanale sąsiednim","methodology_en":"Power in the adjacent channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc w kanale sąsiednim","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Moc w kanale sąsiednim Urzadzenia radiowe E Moc w kanale sasiednim","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Power in the adjacent channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251705","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Moc w kanale kolejnym","methodology_en":"Power in the alternate channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc w kanale kolejnym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Moc w kanale kolejnym Urzadzenia radiowe E Moc w kanale kolejnym","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Power in the alternate channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251706","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Emisje pozapasmowe","methodology_en":"Out-of-band emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje pozapasmowe","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Emisje pozapasmowe Urzadzenia radiowe E Emisje pozapasmowe","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Out-of-band emissions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251707","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Przewodzone emisje niepożądane nadajnika","methodology_en":"Transmitter conducted spurious emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodzone emisje niepożądane nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Przewodzone emisje niepożądane nadajnika Urzadzenia radiowe E Przewodzone emisje niepozadane nadajnika","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter conducted spurious emissions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251708","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Promieniowane emisje niepożądane nadajnika","methodology_en":"Transmitter radiated spurious emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Promieniowane emisje niepożądane nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Promieniowane emisje niepożądane nadajnika Urzadzenia radiowe E Promieniowane emisje niepozadane nadajnika","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter radiated spurious emissions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251709","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Promieniowane emisje od obudowy urządzenia","methodology_en":"Radiated emissions from the equipment enclosure","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Promieniowane emisje od obudowy urządzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Promieniowane emisje od obudowy urządzenia Urzadzenia radiowe E Promieniowane emisje od obudowy urzadzenia","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Radiated emissions from the equipment enclosure","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170a","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Przewodzone emisje niepożądane odbiornika","methodology_en":"Receiver conducted spurious emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodzone emisje niepożądane odbiornika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Przewodzone emisje niepożądane odbiornika Urzadzenia radiowe E Przewodzone emisje niepozadane odbiornika","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver conducted spurious emissions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170b","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Promieniowania niepożądane odbiornika","methodology_en":"Receiver spurious radiations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Promieniowania niepożądane odbiornika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Promieniowania niepożądane odbiornika Urzadzenia radiowe E Promieniowania niepozadane odbiornika","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver spurious radiations","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170c","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Niepożądane emisje przewodzone, MS z przydzielonym kanałem radiowym","methodology_en":"Unwanted conducted emissions, MS with an allocated radio channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niepożądane emisje przewodzone, MS z przydzielonym kanałem radiowym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Niepożądane emisje przewodzone, MS z przydzielonym kanałem radiowym Urzadzenia radiowe E Niepozadane emisje przewodzone, MS z przydzielonym kanalem radiowym","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Unwanted conducted emissions, MS with an allocated radio channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170d","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Niepożądane emisje przewodzone, MS w trybie śledzenia kanału sterującego","methodology_en":"Unwanted conducted emissions, MS in control channel tracking mode","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niepożądane emisje przewodzone, MS w trybie śledzenia kanału sterującego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Niepożądane emisje przewodzone, MS w trybie śledzenia kanału sterującego Urzadzenia radiowe E Niepozadane emisje przewodzone, MS w trybie sledzenia kanalu sterujacego","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Unwanted conducted emissions, MS in control channel tracking mode","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170e","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Niepożądane emisje promieniowane, MS z przydzielonym kanałem radiowym","methodology_en":"Unwanted radiated emissions, MS with an allocated radio channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niepożądane emisje promieniowane, MS z przydzielonym kanałem radiowym","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Niepożądane emisje promieniowane, MS z przydzielonym kanałem radiowym Urzadzenia radiowe E Niepozadane emisje promieniowane, MS z przydzielonym kanalem radiowym","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Unwanted radiated emissions, MS with an allocated radio channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825170f","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Niepożądane emisje promieniowane, MS w trybie śledzenia kanału sterującego","methodology_en":"Unwanted radiated emissions, MS in control channel tracking mode","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niepożądane emisje promieniowane, MS w trybie śledzenia kanału sterującego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Niepożądane emisje promieniowane, MS w trybie śledzenia kanału sterującego Urzadzenia radiowe E Niepozadane emisje promieniowane, MS w trybie sledzenia kanalu sterujacego","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Unwanted radiated emissions, MS in control channel tracking mode","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251710","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Emisje niepożądane w trybie GPRS w konfiguracji z wieloma szczelinami","methodology_en":"Spurious emissions in GPRS mode in multislot configuration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje niepożądane w trybie GPRS w konfiguracji z wieloma szczelinami","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Emisje niepożądane w trybie GPRS w konfiguracji z wieloma szczelinami Urzadzenia radiowe E Emisje niepozadane w trybie GPRS w konfiguracji z wieloma szczelinami","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Spurious emissions in GPRS mode in multislot configuration","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251711","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Intermodulacje nadajnika","methodology_en":"Transmitter intermodulation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Intermodulacje nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Intermodulacje nadajnika Urzadzenia radiowe E Intermodulacje nadajnika","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter intermodulation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251712","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Czas włączania nadajnika","methodology_en":"Transmitter switch-on time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas włączania nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Czas włączania nadajnika Urzadzenia radiowe E Czas wlaczania nadajnika","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter switch-on time","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251713","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Czas wyłączania nadajnika","methodology_en":"Transmitter switch-off time","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas wyłączania nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Czas wyłączania nadajnika Urzadzenia radiowe E Czas wylaczania nadajnika","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter switch-off time","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251714","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Stany przejściowe częstotliwości i mocy nadajnika","methodology_en":"Transient states of the transmitter frequency and power","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stany przejściowe częstotliwości i mocy nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Stany przejściowe częstotliwości i mocy nadajnika Urzadzenia radiowe E Stany przejsciowe czestotliwosci i mocy nadajnika","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transient states of the transmitter frequency and power","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251715","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Moc w stanach przejściowych","methodology_en":"Power under transient conditions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc w stanach przejściowych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Moc w stanach przejściowych Urzadzenia radiowe E Moc w stanach przejsciowych","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Power under transient conditions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251716","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Dopuszczalny zakres częstotliwości pracy","methodology_en":"Permissible operating frequency range","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dopuszczalny zakres częstotliwości pracy","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Dopuszczalny zakres częstotliwości pracy Urzadzenia radiowe E Dopuszczalny zakres czestotliwosci pracy","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Permissible operating frequency range","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251717","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Współczynnik aktywności nadajnika","methodology_en":"Transmitter duty cycle","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik aktywności nadajnika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Współczynnik aktywności nadajnika Urzadzenia radiowe E Wspolczynnik aktywnosci nadajnika","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmitter duty cycle","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251718","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Szerokość zajmowanego pasma (kanału)","methodology_en":"Occupied bandwidth (channel)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szerokość zajmowanego pasma (kanału)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Szerokość zajmowanego pasma (kanału) Urzadzenia radiowe E Szerokosc zajmowanego pasma (kanalu)","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Occupied bandwidth (channel)","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251719","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Szerokość pasma modulacji","methodology_en":"Modulation bandwidth","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szerokość pasma modulacji","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Szerokość pasma modulacji Urzadzenia radiowe E Szerokosc pasma modulacji","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Modulation bandwidth","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171a","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Zachowanie nadajnika w warunkach obniżonego napięcia zasilania","methodology_en":"Behaviour of the transmitter under reduced supply voltage conditions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zachowanie nadajnika w warunkach obniżonego napięcia zasilania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Zachowanie nadajnika w warunkach obniżonego napięcia zasilania Urzadzenia radiowe E Zachowanie nadajnika w warunkach obnizonego napiecia zasilania","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Behaviour of the transmitter under reduced supply voltage conditions","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171b","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Adaptacyjne mechanizmy dostępu do kanału","methodology_en":"Adaptive channel access mechanisms","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Adaptacyjne mechanizmy dostępu do kanału","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Adaptacyjne mechanizmy dostępu do kanału Urzadzenia radiowe E Adaptacyjne mechanizmy dostepu do kanalu","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Adaptive channel access mechanisms","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171c","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Wstrzymanie działania nadajnika fonicznego","methodology_en":"Inhibition of the audio transmitter operation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wstrzymanie działania nadajnika fonicznego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Wstrzymanie działania nadajnika fonicznego Urzadzenia radiowe E Wstrzymanie dzialania nadajnika fonicznego","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Inhibition of the audio transmitter operation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171d","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Czułość odbiornika","methodology_en":"Receiver sensitivity","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czułość odbiornika","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Czułość odbiornika Normy Urzadzenia radiowe E Czulosc odbiornika Normy","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver sensitivity Normy","search_zh":"无线电设备 E Normy","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171e","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Maksymalna czułość użytkowa odbiornika (sygnał doprowadzony)","methodology_en":"Maximum usable sensitivity of the receiver (applied signal)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalna czułość użytkowa odbiornika (sygnał doprowadzony)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Maksymalna czułość użytkowa odbiornika (sygnał doprowadzony) Urzadzenia radiowe E Maksymalna czulosc uzytkowa odbiornika (sygnal doprowadzony)","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Maximum usable sensitivity of the receiver (applied signal)","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825171f","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Maksymalna / średnia czułość użytkowa odbiornika (natężenie pola)","methodology_en":"Maximum / average usable sensitivity of the receiver (field strength)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalna / średnia czułość użytkowa odbiornika (natężenie pola)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Maksymalna / średnia czułość użytkowa odbiornika (natężenie pola) Urzadzenia radiowe E Maksymalna / srednia czulosc uzytkowa odbiornika (natezenie pola)","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Maximum / average usable sensitivity of the receiver (field strength)","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251720","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Selektywność wspólnokanałowa / Podatność na zakłócenia wspólnokanałowe","methodology_en":"Co-channel selectivity / Susceptibility to co-channel interference","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Selektywność wspólnokanałowa / Podatność na zakłócenia wspólnokanałowe","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Selektywność wspólnokanałowa / Podatność na zakłócenia wspólnokanałowe Urzadzenia radiowe E Selektywnosc wspolnokanalowa / Podatnosc na zaklocenia wspolnokanalowe","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Co-channel selectivity / Susceptibility to co-channel interference","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251721","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Selektywność sąsiedniokanałowa / Podatność na zakłócenia w pierwszym kanale sąsiednim","methodology_en":"Adjacent channel selectivity / Susceptibility to interference in the first adjacent channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Selektywność sąsiedniokanałowa / Podatność na zakłócenia w pierwszym kanale sąsiednim","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Selektywność sąsiedniokanałowa / Podatność na zakłócenia w pierwszym kanale sąsiednim Urzadzenia radiowe E Selektywnosc sasiedniokanalowa / Podatnosc na zaklocenia w pierwszym kanale sasiednim","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Adjacent channel selectivity / Susceptibility to interference in the first adjacent channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251722","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Blokowanie odbiornika","methodology_en":"Receiver blocking","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Blokowanie odbiornika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Blokowanie odbiornika Urzadzenia radiowe E Blokowanie odbiornika","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver blocking","search_zh":"无线电设备 E 接收机阻塞","test_object_zh":"无线电设备 E","methodology_zh":"接收机阻塞"},{"_id":"6a5a55f39af9f73f38251723","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Podatność na zakłócenia w drugim kanale sąsiednim","methodology_en":"Susceptibility to interference in the second adjacent channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność na zakłócenia w drugim kanale sąsiednim","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Podatność na zakłócenia w drugim kanale sąsiednim Urzadzenia radiowe E Podatnosc na zaklocenia w drugim kanale sasiednim","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Susceptibility to interference in the second adjacent channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251724","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Blokowanie odbiornika w kanale sąsiednim","methodology_en":"Receiver blocking in the adjacent channel","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Blokowanie odbiornika w kanale sąsiednim","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Blokowanie odbiornika w kanale sąsiednim Urzadzenia radiowe E Blokowanie odbiornika w kanale sasiednim","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver blocking in the adjacent channel","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251725","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Podatność na blokowanie odbiornika falą ciągłą","methodology_en":"Receiver blocking susceptibility by continuous wave","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność na blokowanie odbiornika falą ciągłą","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Podatność na blokowanie odbiornika falą ciągłą Urzadzenia radiowe E Podatnosc na blokowanie odbiornika fala ciagla","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver blocking susceptibility by continuous wave","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251726","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Tłumienie odbioru niepożądanego","methodology_en":"Spurious response rejection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienie odbioru niepożądanego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Tłumienie odbioru niepożądanego Urzadzenia radiowe E Tlumienie odbioru niepozadanego","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Spurious response rejection","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251727","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Tłumienie intermodulacji odbiornika","methodology_en":"Receiver intermodulation response rejection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienie intermodulacji odbiornika","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Tłumienie intermodulacji odbiornika Urzadzenia radiowe E Tlumienie intermodulacji odbiornika","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver intermodulation response rejection","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251728","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Blokowanie lub zmniejszenie czułości","methodology_en":"Blocking or desensitization","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Blokowanie lub zmniejszenie czułości","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Blokowanie lub zmniejszenie czułości Urzadzenia radiowe E Blokowanie lub zmniejszenie czulosci","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Blocking or desensitization","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251729","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"BER w funkcji poziomu sygnału odbieranego (RSL)","methodology_en":"BER as a function of received signal level (RSL)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"BER w funkcji poziomu sygnału odbieranego (RSL)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E BER w funkcji poziomu sygnału odbieranego (RSL) Urzadzenia radiowe E BER w funkcji poziomu sygnalu odbieranego (RSL)","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E BER as a function of received signal level (RSL)","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172a","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Charakterystyki błędu transmisji przy wysokich poziomach sygnału wejściowego","methodology_en":"Transmission error characteristics at high input signal levels","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyki błędu transmisji przy wysokich poziomach sygnału wejściowego","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Charakterystyki błędu transmisji przy wysokich poziomach sygnału wejściowego Urzadzenia radiowe E Charakterystyki bledu transmisji przy wysokich poziomach sygnalu wejsciowego","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Transmission error characteristics at high input signal levels","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172b","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Utrata czułości odbiornika wskutek jednoczesnego nadawania i odbioru","methodology_en":"Receiver desensitization due to simultaneous transmission and reception","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Utrata czułości odbiornika wskutek jednoczesnego nadawania i odbioru","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Utrata czułości odbiornika wskutek jednoczesnego nadawania i odbioru Urzadzenia radiowe E Utrata czulosci odbiornika wskutek jednoczesnego nadawania i odbioru","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Receiver desensitization due to simultaneous transmission and reception","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172c","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Tłumienie odbioru niepożądanego przy pracy dupleksowej","methodology_en":"Spurious response rejection in duplex operation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienie odbioru niepożądanego przy pracy dupleksowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Tłumienie odbioru niepożądanego przy pracy dupleksowej Urzadzenia radiowe E Tlumienie odbioru niepozadanego przy pracy dupleksowej","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Spurious response rejection in duplex operation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172d","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Funkcje sterujące i monitorujące urządzenia","methodology_en":"Control and monitoring functions of the equipment","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcje sterujące i monitorujące urządzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Funkcje sterujące i monitorujące urządzenia Urzadzenia radiowe E Funkcje sterujace i monitorujace urzadzenia","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Control and monitoring functions of the equipment","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172e","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Wzmocnienie poza zakresami częstotliwości roboczych","methodology_en":"Gain outside the operating frequency ranges","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wzmocnienie poza zakresami częstotliwości roboczych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Wzmocnienie poza zakresami częstotliwości roboczych Urzadzenia radiowe E Wzmocnienie poza zakresami czestotliwosci roboczych","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Gain outside the operating frequency ranges","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f3825172f","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia radiowe E","test_object_en":"Radio equipment E","methodology":"Ochrona przed promieniowaniem elektromagnetycznym o częstotliwości radiowej","methodology_en":"Protection against radio frequency electromagnetic radiation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed promieniowaniem elektromagnetycznym o częstotliwości radiowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia radiowe E Ochrona przed promieniowaniem elektromagnetycznym o częstotliwości radiowej Urzadzenia radiowe E Ochrona przed promieniowaniem elektromagnetycznym o czestotliwosci radiowej","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Radio equipment E Protection against radio frequency electromagnetic radiation","search_zh":"无线电设备 E","test_object_zh":"无线电设备 E"},{"_id":"6a5a55f39af9f73f38251730","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (2 – 150) V/m - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (2 – 150) V/m - in the frequency range from 100 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (2 – 150) V/m - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (2 – 150) V/m - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 6 GHz Zakres: (2 – 150) V/m - w zakresie czestotliwosci od 100 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezposrednia enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","categories":["environment"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (2 – 150) V/m - in the frequency range from 100 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量"},{"_id":"6a5a55f39af9f73f38251731","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 6 GHz (z obliczeń) - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 10 MHz to 6 GHz (calculated) - in the frequency range from 100 MHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 6 GHz (z obliczeń) - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń)","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola magnetycznego: - w zakresie częstotliwości od 10 MHz do 6 GHz (z obliczeń) - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola magnetycznego: - w zakresie czestotliwosci od 10 MHz do 6 GHz (z obliczen) - w zakresie czestotliwosci od 100 MHz do 60 GHz (z obliczen) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 10 MHz to 6 GHz (calculated) - in the frequency range from 100 MHz to 60 GHz (calculated) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量"},{"_id":"6a5a55f39af9f73f38251732","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,05 - 200) V/m Metoda pomiarowa bezpośrednia z obliczeniami","methodology_en":"Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,05 - 200) V/m Direct measurement method with calculations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,05 - 200) V/m Metoda pomiarowa bezpośrednia z obliczeniami","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,05 - 200) V/m Metoda pomiarowa bezpośrednia z obliczeniami enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natezenie pola elektrycznego: - w zakresie czestotliwosci od 27 MHz do 6 GHz Zakres: (0,05 - 200) V/m Metoda pomiarowa bezposrednia z obliczeniami enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","categories":["environment"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,05 - 200) V/m Direct measurement method with calculations enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","search_zh":"环境 － 无线电通信设施周围的电磁场：选频测量 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. z 2022 r. poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场：选频测量"},{"_id":"6a5a55f39af9f73f38251733","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 27 MHz to 6 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz (z obliczeń)","reference":"enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natężenie pola magnetycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz (z obliczeń) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natezenie pola magnetycznego: - w zakresie czestotliwosci od 27 MHz do 6 GHz (z obliczen) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Magnetic field strength: - in the frequency range from 27 MHz to 6 GHz (calculated) enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","search_zh":"环境 － 无线电通信设施周围的电磁场：选频测量 enia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场：选频测量"},{"_id":"6a5a55f39af9f73f38251734","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne)","test_object_en":"Workplace environment – electromagnetic field in the workspace during operation of transmitting equipment of radiocommunication systems (mobile telephony base stations; telecommunication and radiocommunication transmitting systems)","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 800 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 800 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 800 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy, Nr 2(92), 2017 r. s.89-131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy, Nr 2(92), 2017 r. s.89-131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne) Natężenie pola elektrycznego: - w zakresie częstotliwości od 800 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy, Nr 2(92), 2017 r. s.89-131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne) Natezenie pola elektrycznego: - w zakresie czestotliwosci od 800 MHz do 60 GHz Zakres: (0,8 – 340) V/m Metoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy, Nr 2(92), 2017 r. s.89-131","categories":["environment"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – electromagnetic field in the workspace during operation of transmitting equipment of radiocommunication systems (mobile telephony base stations; telecommunication and radiocommunication transmitting systems) Electric field strength: - in the frequency range from 800 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method Podstawy i Metody Oceny Środowiska Pracy, Nr 2(92), 2017 r. s.89-131"},{"_id":"6a5a55f39af9f73f38251735","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Emisja zaburzeń elektromagnetycznych","methodology_en":"Emission of electromagnetic disturbances","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja zaburzeń elektromagnetycznych","reference":"Normy","norm_bases":["Normy"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Emisja zaburzeń elektromagnetycznych Normy Urzadzenia elektryczne i elektroniczne E Emisja zaburzen elektromagnetycznych Normy","categories":["environment","electronics"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Emission of electromagnetic disturbances Normy","search_zh":"电气与电子设备 E Normy","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251736","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Napięcie zaburzeń przewodzonych Zakres częstotliwości: 9 kHz ÷ 30 MHz","methodology_en":"Conducted disturbance voltage Frequency range: 9 kHz ÷ 30 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń przewodzonych Zakres częstotliwości: 9 kHz ÷ 30 MHz","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Napięcie zaburzeń przewodzonych Zakres częstotliwości: 9 kHz ÷ 30 MHz Urzadzenia elektryczne i elektroniczne E Napiecie zaburzen przewodzonych Zakres czestotliwosci: 9 kHz ÷ 30 MHz","categories":["electronics"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Conducted disturbance voltage Frequency range: 9 kHz ÷ 30 MHz","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251737","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Emisje harmonicznych prądu","methodology_en":"Current harmonic emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje harmonicznych prądu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Emisje harmonicznych prądu Urzadzenia elektryczne i elektroniczne E Emisje harmonicznych pradu","categories":["electronics"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Current harmonic emissions","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251738","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","methodology_en":"Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia Urzadzenia elektryczne i elektroniczne E Zmiany napiecia, wahania napiecia i migotania swiatla w publicznych sieciach zasilajacych niskiego napiecia","categories":["electronics"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems","search_zh":"电气与电子设备 E 公用低压供电网中的电压变化、电压波动与闪烁","test_object_zh":"电气与电子设备 E","methodology_zh":"公用低压供电网中的电压变化、电压波动与闪烁"},{"_id":"6a5a55f39af9f73f38251739","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 30 MHz ÷1 GHz (komora GTEM)","methodology_en":"Radiated disturbance field strength Frequency range: 30 MHz ÷1 GHz (GTEM cell)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 30 MHz ÷1 GHz (komora GTEM)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 30 MHz ÷1 GHz (komora GTEM) Urzadzenia elektryczne i elektroniczne E Natezenie pola zaburzen promieniowanych Zakres czestotliwosci: 30 MHz ÷1 GHz (komora GTEM)","categories":["electronics"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Radiated disturbance field strength Frequency range: 30 MHz ÷1 GHz (GTEM cell)","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173a","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 1 GHz ÷ 40 GHz (otwarte pole pomiarowe)","methodology_en":"Radiated disturbance field strength Frequency range: 1 GHz ÷ 40 GHz (open area test site)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 1 GHz ÷ 40 GHz (otwarte pole pomiarowe)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Natężenie pola zaburzeń promieniowanych Zakres częstotliwości: 1 GHz ÷ 40 GHz (otwarte pole pomiarowe) Urzadzenia elektryczne i elektroniczne E Natezenie pola zaburzen promieniowanych Zakres czestotliwosci: 1 GHz ÷ 40 GHz (otwarte pole pomiarowe)","categories":["electronics"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Radiated disturbance field strength Frequency range: 1 GHz ÷ 40 GHz (open area test site)","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173b","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na promieniowane pola elektromagnetyczne o częstotliwościach radiowych Zakres częstotliwości: 30 MHz ÷ 6 GHz i natężenie pola do 20 V/m (komora GTEM)","methodology_en":"Immunity to radiated radio-frequency electromagnetic fields Frequency range: 30 MHz ÷ 6 GHz and field strength up to 20 V/m (GTEM cell)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pola elektromagnetyczne o częstotliwościach radiowych Zakres częstotliwości: 30 MHz ÷ 6 GHz i natężenie pola do 20 V/m (komora GTEM)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na promieniowane pola elektromagnetyczne o częstotliwościach radiowych Zakres częstotliwości: 30 MHz ÷ 6 GHz i natężenie pola do 20 V/m (komora GTEM) Urzadzenia elektryczne i elektroniczne E Odpornosc na promieniowane pola elektromagnetyczne o czestotliwosciach radiowych Zakres czestotliwosci: 30 MHz ÷ 6 GHz i natezenie pola do 20 V/m (komora GTEM)","categories":["electronics"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to radiated radio-frequency electromagnetic fields Frequency range: 30 MHz ÷ 6 GHz and field strength up to 20 V/m (GTEM cell)","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173c","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej Urzadzenia elektryczne i elektroniczne E Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej","categories":["electronics"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to conducted disturbances induced by radio-frequency fields","methodology_zh":"射频场感应的传导骚扰抗扰度","search_zh":"电气与电子设备 E 射频场感应的传导骚扰抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173d","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na wyładowania elektrostatyczne Urzadzenia elektryczne i elektroniczne E Odpornosc na wyladowania elektrostatyczne","categories":["electronics"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to electrostatic discharge","methodology_zh":"静电放电抗扰度","search_zh":"电气与电子设备 E 静电放电抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173e","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","methodology_en":"Immunity to electrical fast transients/bursts","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na serie szybkich elektrycznych stanów przejściowych Urzadzenia elektryczne i elektroniczne E Odpornosc na serie szybkich elektrycznych stanow przejsciowych","categories":["electronics"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to electrical fast transients/bursts","methodology_zh":"电快速瞬变脉冲群抗扰度","search_zh":"电气与电子设备 E 电快速瞬变脉冲群抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f3825173f","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na udary","methodology_en":"Immunity to surges","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na udary Urzadzenia elektryczne i elektroniczne E Odpornosc na udary","categories":["electronics"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to surges","methodology_zh":"浪涌抗扰度","search_zh":"电气与电子设备 E 浪涌抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251740","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej Urzadzenia elektryczne i elektroniczne E Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej","categories":["electronics"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to power-frequency magnetic field","methodology_zh":"工频磁场抗扰度","search_zh":"电气与电子设备 E 工频磁场抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251741","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na pole magnetyczne impulsowe","methodology_en":"Immunity to pulse magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne impulsowe","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na pole magnetyczne impulsowe Urzadzenia elektryczne i elektroniczne E Odpornosc na pole magnetyczne impulsowe","categories":["electronics"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to pulse magnetic field","search_zh":"电气与电子设备 E","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251742","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne E","test_object_en":"Electrical and electronic equipment E","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne E Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Urzadzenia elektryczne i elektroniczne E Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia","categories":["electronics"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment E Immunity to voltage dips, short interruptions and voltage variations","methodology_zh":"电压暂降、短时中断与电压变化抗扰度","search_zh":"电气与电子设备 E 电压暂降、短时中断与电压变化抗扰度","test_object_zh":"电气与电子设备 E"},{"_id":"6a5a55f39af9f73f38251743","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia techniki informatycznej i urządzenia zasilające w telekomunikacji","test_object_en":"Information technology equipment and power supply equipment in telecommunications","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: - znakowanie; czytelność, trwałość - ochrona przed porażeniem elektrycznym - napięcia w obwodach SELV i obwodach TNV - obwody o ograniczonym prądzie - moc źródeł o ograniczonej mocy - zabezpieczenia nadprądowe - materiały i klasa izolacji elektrycznej - odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji - badanie okablowania i przewodów zasilających - wytrzymałość mechaniczna - temperatura materiałów i elementów - prąd dotykowy i prąd przewodu ochronnego - wytrzymałość elektryczna napięcia w kablowym systemie dystrybucyjnym","methodology_en":"Features and properties for the purposes of assessing the safety of use: - marking; legibility, durability - protection against electric shock - voltages in SELV circuits and TNV circuits - limited current circuits - power of limited power sources - overcurrent protection - materials and electrical insulation class - clearances, creepage distances and distances through insulation - testing of wiring and supply cords - mechanical strength - temperature of materials and components - touch current and protective conductor current - electric strength of voltages in the cable distribution system","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: - znakowanie; czytelność, trwałość - ochrona przed porażeniem elektrycznym - napięcia w obwodach SELV i obwodach TNV - obwody o ograniczonym prądzie - moc źródeł o ograniczonej mocy - zabezpieczenia nadprądowe - materiały i klasa izolacji elektrycznej - odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji - badanie okablowania i przewodów zasilających - wytrzymałość mechaniczna - temperatura materiałów i elementów - prąd dotykowy i prąd przewodu ochronnego - wytrzymałość elektryczna napięcia w kablowym systemie dystrybucyjnym","reference":"PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014","norm_bases":["PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki informatycznej i urządzenia zasilające w telekomunikacji Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: - znakowanie; czytelność, trwałość - ochrona przed porażeniem elektrycznym - napięcia w obwodach SELV i obwodach TNV - obwody o ograniczonym prądzie - moc źródeł o ograniczonej mocy - zabezpieczenia nadprądowe - materiały i klasa izolacji elektrycznej - odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji - badanie okablowania i przewodów zasilających - wytrzymałość mechaniczna - temperatura materiałów i elementów - prąd dotykowy i prąd przewodu ochronnego - wytrzymałość elektryczna napięcia w kablowym systemie dystrybucyjnym PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014 Urzadzenia techniki informatycznej i urzadzenia zasilajace w telekomunikacji Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania: - znakowanie; czytelnosc, trwalosc - ochrona przed porazeniem elektrycznym - napiecia w obwodach SELV i obwodach TNV - obwody o ograniczonym pradzie - moc zrodel o ograniczonej mocy - zabezpieczenia nadpradowe - materialy i klasa izolacji elektrycznej - odstepy izolacyjne powietrzne, powierzchniowe i grubosc izolacji - badanie okablowania i przewodow zasilajacych - wytrzymalosc mechaniczna - temperatura materialow i elementow - prad dotykowy i prad przewodu ochronnego - wytrzymalosc elektryczna napiecia w kablowym systemie dystrybucyjnym PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014","categories":["materials","construction"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Information technology equipment and power supply equipment in telecommunications Features and properties for the purposes of assessing the safety of use: - marking; legibility, durability - protection against electric shock - voltages in SELV circuits and TNV circuits - limited current circuits - power of limited power sources - overcurrent protection - materials and electrical insulation class - clearances, creepage distances and distances through insulation - testing of wiring and supply cords - mechanical strength - temperature of materials and components - touch current and protective conductor current - electric strength of voltages in the cable distribution system PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014"},{"_id":"6a5a55f39af9f73f38251744","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej wraz z ich zasilaniem","test_object_en":"Audio/video, information technology and telecommunication equipment together with their power supplies","methodology":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: – oznakowanie, czytelność, trwałość; – ochrona przed porażeniem elektrycznym; – klasyfikacja źródeł energii; – napięcia w obwodach; – zabezpieczenia nadprądowe; – obwody o ograniczonym prądzie; – baterie; – odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji; – klasy izolacji elektrycznej; – prąd dotykowy i prąd przewodu ochronnego; – okablowanie i przewody zasilające; – praca w warunkach nienormalnych; – temperatura materiałów i elementów; – klasy palności materiałów; – wytrzymałość mechaniczna; – stabilność mechaniczna i mocowania mechaniczne; – klasy obudów.","methodology_en":"Features and properties for the purposes of assessing the safety of use: – marking, legibility, durability; – protection against electric shock; – classification of energy sources; – voltages in circuits; – overcurrent protection; – limited current circuits; – batteries; – clearances, creepage distances and distances through insulation; – electrical insulation classes; – touch current and protective conductor current; – wiring and supply cords; – operation under abnormal conditions; – temperature of materials and components; – flammability classes of materials; – mechanical strength; – mechanical stability and mechanical fixings; – enclosure classes.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: – oznakowanie, czytelność, trwałość; – ochrona przed porażeniem elektrycznym; – klasyfikacja źródeł energii; – napięcia w obwodach; – zabezpieczenia nadprądowe; – obwody o ograniczonym prądzie; – baterie; – odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji; – klasy izolacji elektrycznej; – prąd dotykowy i prąd przewodu ochronnego; – okablowanie i przewody zasilające; – praca w warunkach nienormalnych; – temperatura materiałów i elementów; – klasy palności materiałów; – wytrzymałość mechaniczna; – stabilność mechaniczna i mocowania mechaniczne; – klasy obudów.","reference":"PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017 | PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020 | eniem p. 9.6","norm_bases":["PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017","PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020","eniem p. 9.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej wraz z ich zasilaniem Cechy i właściwości dla potrzeb oceny bezpieczeństwa użytkowania: – oznakowanie, czytelność, trwałość; – ochrona przed porażeniem elektrycznym; – klasyfikacja źródeł energii; – napięcia w obwodach; – zabezpieczenia nadprądowe; – obwody o ograniczonym prądzie; – baterie; – odstępy izolacyjne powietrzne, powierzchniowe i grubość izolacji; – klasy izolacji elektrycznej; – prąd dotykowy i prąd przewodu ochronnego; – okablowanie i przewody zasilające; – praca w warunkach nienormalnych; – temperatura materiałów i elementów; – klasy palności materiałów; – wytrzymałość mechaniczna; – stabilność mechaniczna i mocowania mechaniczne; – klasy obudów. PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017 | PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020 | eniem p. 9.6 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej wraz z ich zasilaniem Cechy i wlasciwosci dla potrzeb oceny bezpieczenstwa uzytkowania: – oznakowanie, czytelnosc, trwalosc; – ochrona przed porazeniem elektrycznym; – klasyfikacja zrodel energii; – napiecia w obwodach; – zabezpieczenia nadpradowe; – obwody o ograniczonym pradzie; – baterie; – odstepy izolacyjne powietrzne, powierzchniowe i grubosc izolacji; – klasy izolacji elektrycznej; – prad dotykowy i prad przewodu ochronnego; – okablowanie i przewody zasilajace; – praca w warunkach nienormalnych; – temperatura materialow i elementow; – klasy palnosci materialow; – wytrzymalosc mechaniczna; – stabilnosc mechaniczna i mocowania mechaniczne; – klasy obudow. PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017 | PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020 | eniem p. 9.6","categories":["materials","construction"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Audio/video, information technology and telecommunication equipment together with their power supplies Features and properties for the purposes of assessing the safety of use: – marking, legibility, durability; – protection against electric shock; – classification of energy sources; – voltages in circuits; – overcurrent protection; – limited current circuits; – batteries; – clearances, creepage distances and distances through insulation; – electrical insulation classes; – touch current and protective conductor current; – wiring and supply cords; – operation under abnormal conditions; – temperature of materials and components; – flammability classes of materials; – mechanical strength; – mechanical stability and mechanical fixings; – enclosure classes. PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017 | PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020 | eniem p. 9.6"},{"_id":"6a5a55f39af9f73f38251745","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Elektryczne przyrządy pomiarowe, urządzenia sterowania i laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory equipment","methodology":"Cechy i właściwości dla potrzeb oceny: – oznakowanie, trwałość oznakowania; – dokumentacja; – ochrona przed porażeniem elektrycznym:  w warunkach normalnych oraz w warunkach pojedynczego uszkodzenia,  odstępy izolacyjne powietrzne i powierzchniowe,  wytrzymałość dielektryczna,  przyłącza sieciowe i połączenia pomiędzy częściami urządzenia, – ochrona przed zagrożeniami mechanicznymi; – odporność na udary mechaniczne; – ochrona przed rozprzestrzenianiem się ognia; – wartości graniczne temperatury urządzenia i odporność na ciepło; – ochrona przed ryzykiem związanym z płynami; – ochrona przed promieniowaniem, w tym promieniowaniem mikrofalowym i źródłami laserowymi, oraz przed ciśnieniem akustycznym; – ochrona przed wydzielaniem gazów, eksplozją i implozją; – ochrona za pomocą blokad.","methodology_en":"Features and properties for the purposes of assessment: – marking, durability of marking; – documentation; – protection against electric shock:  under normal conditions and under single fault conditions,  clearances and creepage distances,  dielectric strength,  mains connections and connections between parts of the equipment, – protection against mechanical hazards; – resistance to mechanical impact; – protection against the spread of fire; – limit temperature values of the equipment and resistance to heat; – protection against hazards related to fluids; – protection against radiation, including microwave radiation and laser sources, and against sound pressure; – protection against liberated gases, explosion and implosion; – protection by means of interlocks.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Cechy i właściwości dla potrzeb oceny: – oznakowanie, trwałość oznakowania; – dokumentacja; – ochrona przed porażeniem elektrycznym:  w warunkach normalnych oraz w warunkach pojedynczego uszkodzenia,  odstępy izolacyjne powietrzne i powierzchniowe,  wytrzymałość dielektryczna,  przyłącza sieciowe i połączenia pomiędzy częściami urządzenia, – ochrona przed zagrożeniami mechanicznymi; – odporność na udary mechaniczne; – ochrona przed rozprzestrzenianiem się ognia; – wartości graniczne temperatury urządzenia i odporność na ciepło; – ochrona przed ryzykiem związanym z płynami; – ochrona przed promieniowaniem, w tym promieniowaniem mikrofalowym i źródłami laserowymi, oraz przed ciśnieniem akustycznym; – ochrona przed wydzielaniem gazów, eksplozją i implozją; – ochrona za pomocą blokad.","reference":"PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019","norm_bases":["PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy pomiarowe, urządzenia sterowania i laboratoryjne Cechy i właściwości dla potrzeb oceny: – oznakowanie, trwałość oznakowania; – dokumentacja; – ochrona przed porażeniem elektrycznym:  w warunkach normalnych oraz w warunkach pojedynczego uszkodzenia,  odstępy izolacyjne powietrzne i powierzchniowe,  wytrzymałość dielektryczna,  przyłącza sieciowe i połączenia pomiędzy częściami urządzenia, – ochrona przed zagrożeniami mechanicznymi; – odporność na udary mechaniczne; – ochrona przed rozprzestrzenianiem się ognia; – wartości graniczne temperatury urządzenia i odporność na ciepło; – ochrona przed ryzykiem związanym z płynami; – ochrona przed promieniowaniem, w tym promieniowaniem mikrofalowym i źródłami laserowymi, oraz przed ciśnieniem akustycznym; – ochrona przed wydzielaniem gazów, eksplozją i implozją; – ochrona za pomocą blokad. PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019 Elektryczne przyrzady pomiarowe, urzadzenia sterowania i laboratoryjne Cechy i wlasciwosci dla potrzeb oceny: – oznakowanie, trwalosc oznakowania; – dokumentacja; – ochrona przed porazeniem elektrycznym:  w warunkach normalnych oraz w warunkach pojedynczego uszkodzenia,  odstepy izolacyjne powietrzne i powierzchniowe,  wytrzymalosc dielektryczna,  przylacza sieciowe i polaczenia pomiedzy czesciami urzadzenia, – ochrona przed zagrozeniami mechanicznymi; – odpornosc na udary mechaniczne; – ochrona przed rozprzestrzenianiem sie ognia; – wartosci graniczne temperatury urzadzenia i odpornosc na cieplo; – ochrona przed ryzykiem zwiazanym z plynami; – ochrona przed promieniowaniem, w tym promieniowaniem mikrofalowym i zrodlami laserowymi, oraz przed cisnieniem akustycznym; – ochrona przed wydzielaniem gazow, eksplozja i implozja; – ochrona za pomoca blokad. PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019","categories":["construction"],"row_index":72,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical measuring instruments, control equipment and laboratory equipment Features and properties for the purposes of assessment: – marking, durability of marking; – documentation; – protection against electric shock:  under normal conditions and under single fault conditions,  clearances and creepage distances,  dielectric strength,  mains connections and connections between parts of the equipment, – protection against mechanical hazards; – resistance to mechanical impact; – protection against the spread of fire; – limit temperature values of the equipment and resistance to heat; – protection against hazards related to fluids; – protection against radiation, including microwave radiation and laser sources, and against sound pressure; – protection against liberated gases, explosion and implosion; – protection by means of interlocks. PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019"},{"_id":"6a5a55f39af9f73f38251746","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Wytrzymałość i odporność na zimno (Próba A) Temperatura minimalna – 40 ºC","methodology_en":"Strength and resistance to cold (Test A) Minimum temperature – 40 ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na zimno (Próba A) Temperatura minimalna – 40 ºC","reference":"EN 60068-2-1:2009","norm_bases":["EN 60068-2-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Wytrzymałość i odporność na zimno (Próba A) Temperatura minimalna – 40 ºC EN 60068-2-1:2009 Urzadzenia elektryczne i elektroniczne Wytrzymalosc i odpornosc na zimno (Proba A) Temperatura minimalna – 40 ºC EN 60068-2-1:2009","categories":["electronics"],"row_index":73,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Strength and resistance to cold (Test A) Minimum temperature – 40 ºC EN 60068-2-1:2009","search_zh":"电气与电子设备 EN 60068-2-1:2009","test_object_zh":"电气与电子设备"},{"_id":"6a5a55f39af9f73f38251747","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Wytrzymałość i odporność na suche gorąco (Próba B) Temperatura maksymalna + 85 ºC","methodology_en":"Strength and resistance to dry heat (Test B) Maximum temperature + 85 ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na suche gorąco (Próba B) Temperatura maksymalna + 85 ºC","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Wytrzymałość i odporność na suche gorąco (Próba B) Temperatura maksymalna + 85 ºC PN-EN 60068-2-2:2009 Urzadzenia elektryczne i elektroniczne Wytrzymalosc i odpornosc na suche goraco (Proba B) Temperatura maksymalna + 85 ºC PN-EN 60068-2-2:2009","categories":["electronics"],"row_index":74,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Strength and resistance to dry heat (Test B) Maximum temperature + 85 ºC PN-EN 60068-2-2:2009","search_zh":"电气与电子设备 PN-EN 60068-2-2:2009","test_object_zh":"电气与电子设备"},{"_id":"6a5a55f39af9f73f38251748","lab_id":"69ad52a3de79e566650fb129","country":"PL","accr_number":"AB 121","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Wytrzymałość i odporność na wilgotne gorąco stałe (Próby Ca i Cb) Wilgotność do 93 % Zakres temperatury: + 20 ºC - + 55 ºC","methodology_en":"Strength and resistance to damp heat, steady state (Tests Ca and Cb) Humidity up to 93 % Temperature range: + 20 ºC - + 55 ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na wilgotne gorąco stałe (Próby Ca i Cb) Wilgotność do 93 % Zakres temperatury: + 20 ºC - + 55 ºC","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Wytrzymałość i odporność na wilgotne gorąco stałe (Próby Ca i Cb) Wilgotność do 93 % Zakres temperatury: + 20 ºC - + 55 ºC PN-EN 60068-2-78:2013-11 Urzadzenia elektryczne i elektroniczne Wytrzymalosc i odpornosc na wilgotne goraco stale (Proby Ca i Cb) Wilgotnosc do 93 % Zakres temperatury: + 20 ºC - + 55 ºC PN-EN 60068-2-78:2013-11","categories":["electronics"],"row_index":75,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Strength and resistance to damp heat, steady state (Tests Ca and Cb) Humidity up to 93 % Temperature range: + 20 ºC - + 55 ºC PN-EN 60068-2-78:2013-11","search_zh":"电气与电子设备 PN-EN 60068-2-78:2013-11","test_object_zh":"电气与电子设备"}],"has_pdf":true}